Roxar Multiphase meter
              MPFM 2600
                - Turning information into value




This presentation is provided for information purposes only. It should not be used or considered as an offer to sell or a solicitation of an offer to buy any securities.
Any opinions expressed are subject to change without prior notice. Although all reasonable care has been taken to ensure that the information herein is not misleading,
Roxar ASA makes no representation or warranty expressed or implied as to its accuracy or completeness. Neither Roxar ASA, its employees, nor any other person
connected with it, accepts any liability whatsoever for any direct or consequential loss of any kind arising out of the use or reliance on the information in this presentation.
This presentation is prepared for general circulation and general information.

                                                                                                                                                                                   December 2009
Roxar’s Mission statement:

  Our mission is simply:

  TO ENABLE OUR CUSTOMERS TO MAXIMIZE RESERVOIR PERFORMANCE

  Roxar is the industrial inventor and pioneer of multiphase metering and
  sand monitoring, and a leading global supplier of real-time
  measurements solutions for production optimization, enhanced oil
  recovery and flow assurance.

  Roxar’s instrument design philosophy is based upon the following
  principles:

  - Keep it simple
  - Build in redundancy
  - Maximize use of direct measurements
What is a multiphase meter

  - A non-intrusive multiphase flow measurements device that
  provides real-time and continuous three-phase measurements



   Measures
    • fraction and velocity of oil
    • fraction and velocity of water
    • fraction and velocity of gas

   Outputs
    • Oil rate
    • Water rate
    • Gas rate
Roxar Multiphase meter applications


  Traditional layout using
  separators
   Complex piping and
  valve arrangement
   Limited / periodic
  testing only
Roxar Multiphase meter applications

Using inline Multiphase
meters

 Real-time and continuous
monitoring
Excluding test separator on
new/upgrade installations
 Early detection of water/gas
breakthrough
 Improved well control

 Reduction in Opex and Capex

Ultimately - Optimize the lifetime
of the field
Roxar Multiphase and Wetgas meters

  Subsea meters               Topside meters
     Gamma        Non-gamma      Gamma         Wetgas
Multiphase Meters Today
 A growing market
 Significant take-up
 A vital component of field production (production
  monitoring, individual well testing, production allocation
  & reservoir monitoring)




                                                               7
55 operators
in 72 countries
Recent Customers – Multiphase and Wetgas meters
The industrial inventor of multiphase metering
Roxar started the development of multiphase metering technology
in 1984 and can celebrate 25 years of innovation!
From 1st to 3rd Generation
The first generation of multiphase meters:
        Assumed homogenous flow conditions
        Incorporated models based on a single
         flow velocity
The second generation of multiphase
  meters:
        Dual cross correlation (individual Liquid
         and Gas velocity measurements)
        Sophisticated signal processing
        The dual velocity model is a well suited
         model, but still a simplification of very
         complex flow patterns
                                                     11
2nd generation MPFM


   Real system        Dual velocity system




  DP22 electrode       2 volumes
     system                 - Large bubble volume
                            - Dispersed phase
    Multiphase /       2 velocities
    multi-velocity          - Large bubble velocity
                            - Dispersed phase velocity
Witness a step-change in
technological sophistication




                               13
Roxar MPFM 2600 – key elements
Simple, light-weight design, 80% weight reduction and half the
length compared to the previous generation

  The image shows the
    relative difference in size
    for a typical 3” meter

  Weight: 550 vs.110 kg

  Length: 1300 vs. 650 mm


Added value:
 Simple installation
 Easy handling
 Greater flexibility
Roxar MPFM 2600 – key elements
Field replaceable insert venturi

 Four pressure tapping’s and ring
chamber improves accuracy and stability
(same design as for subsea meters)

 A field replaceable insert venturi sleeve

Added value:
 Extended service life
 Extended operating range – can
  easily be replaced in the field
 Removes uncertainties when
  sizing meters based on predicted
  production forecasts
Roxar MPFM 2600 – key elements
Compact, integrated measurement solution for pressure,
differential pressure and temperature

   Multivariable transmitter, Rosemount 3095MA

 Enables highly sensitive, accurate, DP, P and T measurements

 No impulse lines

Added value:
 Combines the best features from
  remote seal solutions and open
  impulse tubing
 Limits the potential for clogging
 Easy field replacement
Roxar MPFM 2600 – key elements
Non-radioactive version covering most operating conditions -
gamma version for special applications and high GVF

 Base version is non-gamma –
suited for installations < 95% GVF
                                               Upgrade
                                               with mini-
                                                gamma
 For applications with very high GVF           system

 (>95%), the gamma version is
 recommended
Added value:
 No source handling, paper work
  or import licenses needed
 The gamma system can easily be
  retrofitted if and when flow
  conditions so dictate
Roxar 2600 class – key elements
New compact gamma system for special and high GVF
applications

 Developed by Roxar in collaboration with partners. Patent pending
 Source holder and detector specially designed for the application
 Designed and qualified according to ISO 7205 and ISO 2919
 ISO 13628-2006 requirements used for temperature and vibration
testing
Roxar 2600 class – key elements
New compact gamma system

Source
 Isotope: Cs-137


 Nominal activity: 1mCi


 Maximum surface dose-rate: 5 µSv/hour


 Half-life: 30.2 years


 Source capsule: double encapsulation
Roxar 2600 class – key elements
New compact gamma system

Detector
 Digital signal transmission


 Automatic stabilization integrated in detector

 Internal temperature measurement

 Extended diagnostics
Roxar 2600 class – key elements

Benefits of the new gamma system
 Source and detector closer to the
   flow – improved measurements
 Build-in stability functionality –
   measurements not affected by
   temperature fluctuations and aging
   of the detector
 Reduced weight and length –
   simplifies installation on site
 Digital signal transmission – allows
   for improved data transfer and
   diagnostics
Introducing Roxar Zector technology

 Key components of Roxar’s Zector technology:
-DP26 electrode geometry
-New impedance electronics
-Voxel based signal processing (4D pixels)

 Voxel based signal processing and DP26 electrode geometry
provides:
        - multiple flow velocities
        - near wall measurements

 The new technology operates seamlessly in both oil- and water-
continuous flow which results in rapid detection of regime changes
Roxar MPFM 2600 – key elements
Roxar Zector® technology
Key components:

 DP26 electrode geometry
 New impedance electronics
 Advanced signal processing

Replaces the capacitance and inductive electronics, and uses the same set
of electrodes

Measures both components simultaneously - operates seamlessly in both oil-
and water-continuous flow

Analog Devices Blackfin® Processor - specially developed for real time
image processing and streaming media application
Roxar MPFM 2600 – key elements
 Roxar Zector® technology

  Traditional bulk-
 measurement
  Near-wall-measurement
  Rotational measurement
Added value:
Improved measurement
uncertainty
Scale / Wax detection / correction
Asymmetric flow detection
Multiple velocity measurements
Roxar MPFM 2600 – key elements
 Roxar Zector® technology

  Traditional bulk-
 measurement
  Near-wall-measurement
  Rotational measurement
Added value:
Improved measurement
uncertainty
Scale / Wax detection / correction
Asymmetric flow detection
Multiple velocity measurements
2nd generation MPFM


   Real system        Dual velocity system




  Dp22 electrode       2 volumes
     system                 - Large bubble volume (r, l)
                            - Dispersed phase
    Multiphase /       2 velocities
    multi-velocity          - Large bubble velocity
                            - Dispersed phase velocity
Roxar MPFM 2600: 3rd generation

Real system                             4D voxel system




DP26 electrode system         • Asymmetric Large bubble volume
                              • Variable dispersed phase volumes
Multiphase / Multi-velocity   • Near wall measurement volumes
                              • Large bubble velocity
                              • Dispersed phase velocity
                              • Velocities per sector
Technology comparison - MPFM 1900VI vs. MPFM 2600

        Measurement                 MPFM 1900VI   MPFM 2600
Mixture density and GLR
       Single Energy Gamma              V             V
Fraction measurements
       Permittivity / Capacitance       V             V
       Conductivity / Inductance        V
       Conductivity / Conductance                     V
       2-plane Electrodes               V             V
       6-plane Electrodes                             V
Flow
       Venturi                          V             V
       Insert sleeve                                  V
       Cross correlation                V             V
Primary measurements
       Pressure                         V             V
       Differential pressure            V             V
       Temperature                      V             V
25 years of experience in multiphase metering
– the MPFM 2600 is next step
Specifications
Qualification testing

 The Roxar Multiphase meter 2600 has
been extensively tested, both statically and
dynamically, including:
 - Pressure and temperature cycling
 - Calibration and sensitivity testing
 - Flow testing

 The loop testing has demonstrated
superior performance for measurement of all
three phases

 As a result, the operating envelope has
been widened, and uncertainty is reduced
Flow loop performance testing

December 2008   -“Measurement accuracy appears consistent       June / July 2009
                across water and oil continuous regimes”

                -“Overall excellent performance of the meter”

                -“In a comparison against the manufacturer’s
                performance specification, all of the meters
                individual measurements were within the
                current published uncertainty specification”

                - “The meter performed extremely well on
                liquid flow, gas flow and liquid water cut”
Results - Flow loop testing
                              December 2008
Serial number:          1431.06 + 1676.08
                                 Qliquid                                                                             Date:          19. December 2008
                                 Deviation in Liquid Flow Rate vs: Gas Volume Fraction
                                                                                                                  Project :        30075               Dstar
                                      3.0 '' - Roxar Multiphase meter
                           15




                           10




                            5
Deviation Liquid (rel %)




                            0
                                 0                     15                     30         45           60                      75                          90



                            -5




                           -10




                           -15
                                                                                              GVF %
                                                                                                                                           Combined Uncertainty


                                                                                                                                           - Roxar Multiphase meter
Serial number:        1431.06 + 1676.08
                                                                                                                                             Date:    19.December 2009
                                Gas Flow Rate
                                                                                                                                          Project :   30075               Dstar
                                Multiphase meter vs. Reference
                               150




                               125
Qgas Multiphase meter [m3/h]




                               100




                                75




                                50




                                25




                                 0
                                     0                    25              50                            75                       100                    125                       15
                                                                                              Qgas Reference [ m3/h]


                                                                 Org. Qgas oilcont MPFM2600                        Org. Qgas watercont MPFM2600                      10%
Serial number:           1431.06 + 1676.08
                                  Qgas
                                  (Deviation in Gas Flow Rate vs. Gas Volume Fraction)                                  Date:         19. December 2008

                                     3.0 '' - Roxar Multiphase meter                                                 Project :        30075               Dstar
                        35




                        25




                        15
Gas deviation (rel %)




                         5



                              0                           15                   30        45             60                       75                          90
                         -5




                        -15




                        -25




                        -35
                                                                                              GVF (%)
                                                                                                                                              Combined Uncertainty


                                                                                                                                              - Roxar Multiphase meter
Serial number:            1431.06 + 1676.08
                                                                                                                   Date:         19.December 2009
                      Watercut
                                                                                                                Project :        30075               Dstar
                      Multiphase meter vs. Reference
                      100



                      90



                      80



                      70
Watercut - MPFM [%]




                      60



                      50



                      40



                      30



                      20



                      10



                        0
                            0         10               20   30   40              50               60       70               80                90             10

                                                                      Watercut - Reference [%]




                                                                                                 5%
Serial number:          1431.06 + 1676.08
                                 Watercut                                                                   Date:         19.December 2009
                                 Deviation in WC vs. Gas Volume Fraction
                                                                                                         Project :        30075               Dstar
                                  3.0 '' - Roxar Multiphase meter
                       15




                       10




                        5
Absolute deviation %




                        0
                             0                       15                    30   45           60                      75                               90



                        -5




                       -10




                       -15
                                                                                     GVF %
                                                                                                                                  Org. WLR MPFM2600
                                                                                                                                  Combined Uncertainty
                                                                                                                                  - Roxar Multiphase meter
Results - Flow loop testing
                              June / July 2009
NEL Test Results: Multiphase Results
                                        Liquid Flow Rate
                                        Multiphase meter vs. Reference
                               50




                               40
Qliq Multiphase meter [m3/h]




                               30




                               20




                               10



                                                                                                                Qliq oilcont.
                                                                                                                Qliq w atercont.
                                                                                                                +/- 5 %

                               0
                                    0                             10     20                           30   40                      50

                                                                              Qliq Reference [m3/h]



                                                                                                                                        39
NEL Test Results: Multiphase Results
                                 Deviation in Liquid Flow Rate vs: Gas Volume Fraction                      MPFM2600
                           15




                           10




                            5
Deviation Liquid (rel %)




                            0
                                 0           15          30          45           60     75                90




                            -5




                           -10
                                                                                              Org. Qliq_Oilcont.
                                                                                              Org. Qliq_Watercont.
                                                                                              Combined Uncertainty
                                                                                              - Roxar Multiphase meter

                           -15
                                                                          GVF %
NEL Test Results: Multiphase Results
                                    Gas Flow Rate
                                    Multiphase meter vs. Reference
                              210

                              200

                              190

                              180

                              170

                              160

                              150

                              140
                eter [m3/h]




                              130

                              120
 gas ultiphase m




                              110

                              100

                              90
Q M




                              80

                              70

                              60

                              50

                              40

                              30
                                                                                                                                                    Qgas oilcont
                              20
                                                                                                                                                    Qgas w atercont
                              10                                                                                                                    +/- 8 %

                               0
                                    0     10    20     30     40     50   60   70   80      90   100   110   120      130   140   150   160   170   180   190      200   210

                                                                                         Qgas NEL Reference [ m3/h]
NEL Test Results: Multiphase Results
                          Deviation in Gas Flow Rate vs. Gas Volume Fraction                           MPFM2600
                        30



                        25



                        20



                        15



                        10
Gas deviation (rel %)




                         5



                         0
                              0      15         30         45             60   75                     90

                         -5



                        -10



                        -15



                        -20

                                                                                    Qgas_Oilcont
                        -25                                                         Qgas_Watercont
                                                                                    Combined Uncertainty
                                                                                    - Roxar Multiphase meter
                        -30
                                                                GVF (%)
NEL Test Results: Multiphase Results
                            Watercut
                      100 Multiphase meter vs. Reference



                       90



                       80



                       70
 atercut - MPFM [%]




                       60



                       50
W




                       40



                       30



                       20



                       10                                                                            WLR_Oilcont.
                                                                                                     WLR_Watercont.
                                                                                                     +/- 5 %
                        0
                            0          10            20    30   40         50         60   70   80             90     100

                                                                Watercut - Reference [%]
NEL Test Results: Multiphase Results
                       Deviation in WC vs. Gas Volume Fraction                                           MPFM
                      15




                      10




                       5
Absolute deviation%




                       0
                            0     15        30         45           60   75                     90




                       -5




                      -10

                                                                              WLR-w ater cont.
                                                                              WLR oil cont.
                                                                              Combined Uncertainty
                                                                              - Roxar Multiphase meter

                      -15
                                                            GVF %
Wet gas test – TUV NEL

 •2 phase test version based on
 PVT input (density and LGR)

 •Based on Chisholm wet gas model
 + Roxar calibration model
Wet gas test – TUV NEL
Wet gas sensitivity – TUV NEL

•The permittivity of the wet gas was measured using the MPFM 2600
•The TUV NEL loop was operated on condensate with no water
• It is possible to calculate the expected sensitivity to a change in water
fraction based on the sensitivity in the permittivity measurements
• A change in GVF from 99.55% to 99.79% could easily be measured,
resulting in a change in permittivity of -0.00265 abs
• This corresponds to a water fraction sensitivity of +/-0.018% abs
New Performance Specification

Improved uncertainty
specification for all three
phases

Uncertainty specification for
both Multiphase and Wetgas
mode

0-100 % GVF and 0-100 %
WLR

Same specification for both
oil and water continues flow


                                 48
Roxar Fieldwatch
Are your investments working at peak performance?

How can you ensure:
 the best performance of the multiphase meter when installed?
 getting remote service during the life of the multiphase meter?
 the best access of data from the multiphase meter?
 avoiding data overflow from multiphase meters?

Answer: Roxar Fieldwatch

 Roxar Fieldwatch is the instrument interface software for all RFM
    instruments
   Set up of instruments with full service console capabilities
   Storage of large amount of data
   User interface through Roxar Field explorer
   Industry standard interfaces with external networks
Why Roxar Fieldwatch
    When installing the state-of-the-art Roxar Multiphase meter, Roxar
      Fieldwatch is the best software to store, view and most importantly service
      this during its operation

Roxar Field                                                        Many user of data
Explorer                                                           simultaneously




Roxar Field                                                        One server installed
server                                                             on site




Roxar Field
interfaces


Roxar Multiphase                                                   Many meters connected
meter                                                              simultaneously
Roxar Fieldwatch - Features

 Interface with third party network systems to connect/interface with the
    Roxar Multiphase meter
   Specialized viewing features for Roxar Multiphase meter
   Data storage
   Data display
   Data transfer
   Service Console
Installation
 Typical communication set-up

     Safe area                                Hazardous area
     Roxar Fieldwatch         Flow Computer




 Distributed Control System
Installation
 Typical communication set-up




                                  1. MPFM 2600
                                  2. Flow computer, EExd
X-Ray Based Densitometer

 Nuclear gamma-sources
 traditionally required for optimal
 MPFM measurements (high
 accuracy and full GVF range).

 X-ray based densitometer provides
 the same or higher measurement
 accuracy without the radioactive
 isotope.
                                                                102


                                                                100
 Special requirements concerning                                98

 storage, importing, handling during
                                                          GVF
                                                                96                                   MPFM
                                                                                                     FluorX
 installation, the return of used                               94                                   NEL ref



 sources etc avoided.                                           92


                                                                90
                                                                      0   5   10       15       20     25           30
                                                                                   Test point


The obvious benefit when using an X-ray source is the possibility to switch off the radiation!
                                                                                                               54
Today…Tomorrow…
              Welcome to what’s next, welcome to
              the future

                Roxar Multiphase meter MPFM 2600
                Built on Zector® Technology



This presentation is provided for information purposes only. It should not be used or considered as an offer to sell or a solicitation of an offer to buy any securities.
Any opinions expressed are subject to change without prior notice. Although all reasonable care has been taken to ensure that the information herein is not misleading,
Roxar ASA makes no representation or warranty expressed or implied as to its accuracy or completeness. Neither Roxar ASA, its employees, nor any other person
connected with it, accepts any liability whatsoever for any direct or consequential loss of any kind arising out of the use or reliance on the information in this presentation.
This presentation is prepared for general circulation and general information.

Weitere ähnliche Inhalte

Was ist angesagt?

Lateral log deep lld
Lateral log deep lldLateral log deep lld
Lateral log deep lldShah Naseer
 
Design basis - PROCESS DESIGN FUNDAMENTALS
Design basis  - PROCESS DESIGN FUNDAMENTALSDesign basis  - PROCESS DESIGN FUNDAMENTALS
Design basis - PROCESS DESIGN FUNDAMENTALSiFluids Engineering
 
Pressure Draw Down Test
Pressure Draw Down TestPressure Draw Down Test
Pressure Draw Down TestMubarik Rao
 
Natural gas processing technology condensate stabilization
Natural gas processing technology   condensate stabilizationNatural gas processing technology   condensate stabilization
Natural gas processing technology condensate stabilizationMohamad Abdelraof
 
Produced Water Treatment to Enhance Oil Recovery
Produced Water Treatment to Enhance Oil RecoveryProduced Water Treatment to Enhance Oil Recovery
Produced Water Treatment to Enhance Oil Recoverygusgon
 
introduction to completions and workovers (2)
introduction to completions and workovers (2)introduction to completions and workovers (2)
introduction to completions and workovers (2)Dr. Arzu Javadova
 
Q913 re1 w3 lec 10
Q913 re1 w3 lec 10Q913 re1 w3 lec 10
Q913 re1 w3 lec 10AFATous
 
Oilfield Produced water management
Oilfield Produced water managementOilfield Produced water management
Oilfield Produced water managementCharles Chindove
 
Analyzing Multi-zone completion using multilayer by IPR (PROSPER)
Analyzing Multi-zone completion using multilayer by IPR (PROSPER)  Analyzing Multi-zone completion using multilayer by IPR (PROSPER)
Analyzing Multi-zone completion using multilayer by IPR (PROSPER) Arez Luqman
 
Overview about Coriolis Flow Meter
Overview about Coriolis Flow Meter Overview about Coriolis Flow Meter
Overview about Coriolis Flow Meter Mostafa Ahmed Zein
 
Natural gas processing technology lng process
Natural gas processing technology   lng processNatural gas processing technology   lng process
Natural gas processing technology lng processMohamad Abdelraof
 
One day gas lift system course
One day gas lift system course One day gas lift system course
One day gas lift system course Giuseppe Moricca
 
John Power Point Flow Meters
John Power Point Flow MetersJohn Power Point Flow Meters
John Power Point Flow MetersJohn McCutcheon
 
Drilling Fluids Mud
Drilling Fluids MudDrilling Fluids Mud
Drilling Fluids MudM.T.H Group
 

Was ist angesagt? (20)

Lateral log deep lld
Lateral log deep lldLateral log deep lld
Lateral log deep lld
 
Flow measurement
Flow measurement Flow measurement
Flow measurement
 
Design basis - PROCESS DESIGN FUNDAMENTALS
Design basis  - PROCESS DESIGN FUNDAMENTALSDesign basis  - PROCESS DESIGN FUNDAMENTALS
Design basis - PROCESS DESIGN FUNDAMENTALS
 
Pressure Draw Down Test
Pressure Draw Down TestPressure Draw Down Test
Pressure Draw Down Test
 
Vortex flow Meter
Vortex flow MeterVortex flow Meter
Vortex flow Meter
 
Natural gas processing technology condensate stabilization
Natural gas processing technology   condensate stabilizationNatural gas processing technology   condensate stabilization
Natural gas processing technology condensate stabilization
 
Produced Water Treatment to Enhance Oil Recovery
Produced Water Treatment to Enhance Oil RecoveryProduced Water Treatment to Enhance Oil Recovery
Produced Water Treatment to Enhance Oil Recovery
 
Control valves
Control  valvesControl  valves
Control valves
 
introduction to completions and workovers (2)
introduction to completions and workovers (2)introduction to completions and workovers (2)
introduction to completions and workovers (2)
 
Well Workover
Well Workover Well Workover
Well Workover
 
Q913 re1 w3 lec 10
Q913 re1 w3 lec 10Q913 re1 w3 lec 10
Q913 re1 w3 lec 10
 
Oilfield Produced water management
Oilfield Produced water managementOilfield Produced water management
Oilfield Produced water management
 
Analyzing Multi-zone completion using multilayer by IPR (PROSPER)
Analyzing Multi-zone completion using multilayer by IPR (PROSPER)  Analyzing Multi-zone completion using multilayer by IPR (PROSPER)
Analyzing Multi-zone completion using multilayer by IPR (PROSPER)
 
Overview about Coriolis Flow Meter
Overview about Coriolis Flow Meter Overview about Coriolis Flow Meter
Overview about Coriolis Flow Meter
 
Natural gas processing technology lng process
Natural gas processing technology   lng processNatural gas processing technology   lng process
Natural gas processing technology lng process
 
One day gas lift system course
One day gas lift system course One day gas lift system course
One day gas lift system course
 
Control valve
Control valveControl valve
Control valve
 
Well test analysis
Well test analysisWell test analysis
Well test analysis
 
John Power Point Flow Meters
John Power Point Flow MetersJohn Power Point Flow Meters
John Power Point Flow Meters
 
Drilling Fluids Mud
Drilling Fluids MudDrilling Fluids Mud
Drilling Fluids Mud
 

Andere mochten auch

Docker experience @inbotapp
Docker experience @inbotappDocker experience @inbotapp
Docker experience @inbotappJilles van Gurp
 
USGS Report on the Impact of Marcellus Shale Drilling on Forest Animal Habitats
USGS Report on the Impact of Marcellus Shale Drilling on Forest Animal HabitatsUSGS Report on the Impact of Marcellus Shale Drilling on Forest Animal Habitats
USGS Report on the Impact of Marcellus Shale Drilling on Forest Animal HabitatsMarcellus Drilling News
 
Heterogenous Persistence
Heterogenous PersistenceHeterogenous Persistence
Heterogenous PersistenceJervin Real
 
Open Secrets of the Defense Industry: Building Your Own Intelligence Program ...
Open Secrets of the Defense Industry: Building Your Own Intelligence Program ...Open Secrets of the Defense Industry: Building Your Own Intelligence Program ...
Open Secrets of the Defense Industry: Building Your Own Intelligence Program ...Sean Whalen
 
Demystifying Security Analytics: Data, Methods, Use Cases
Demystifying Security Analytics: Data, Methods, Use CasesDemystifying Security Analytics: Data, Methods, Use Cases
Demystifying Security Analytics: Data, Methods, Use CasesPriyanka Aash
 
Adaptive Content Show & Tell - Austin Content
Adaptive Content Show & Tell - Austin ContentAdaptive Content Show & Tell - Austin Content
Adaptive Content Show & Tell - Austin Contentcdelk
 
How to build a Distributed Serverless Polyglot Microservices IoT Platform us...
How to build a Distributed Serverless Polyglot Microservices IoT Platform us...How to build a Distributed Serverless Polyglot Microservices IoT Platform us...
How to build a Distributed Serverless Polyglot Microservices IoT Platform us...Animesh Singh
 
Micro Services - Small is Beautiful
Micro Services - Small is BeautifulMicro Services - Small is Beautiful
Micro Services - Small is BeautifulEberhard Wolff
 
Combining sentences with the words although and despite
Combining sentences with the words although and despiteCombining sentences with the words although and despite
Combining sentences with the words although and despiteEmily Kissner
 
Urban legends - PJ Hagerty - Codemotion Amsterdam 2017
Urban legends - PJ Hagerty - Codemotion Amsterdam 2017Urban legends - PJ Hagerty - Codemotion Amsterdam 2017
Urban legends - PJ Hagerty - Codemotion Amsterdam 2017Codemotion
 
Deploying services: automation with docker and ansible
Deploying services: automation with docker and ansibleDeploying services: automation with docker and ansible
Deploying services: automation with docker and ansibleJohn Zaccone
 
Data Visualization on the Tech Side
Data Visualization on the Tech SideData Visualization on the Tech Side
Data Visualization on the Tech SideMathieu Elie
 
Building Awesome APIs with Lumen
Building Awesome APIs with LumenBuilding Awesome APIs with Lumen
Building Awesome APIs with LumenKit Brennan
 
Acts 6:1-7 ~ Organic Growth of the Early Church (pt. 1)
Acts 6:1-7 ~ Organic Growth of the Early Church (pt. 1)Acts 6:1-7 ~ Organic Growth of the Early Church (pt. 1)
Acts 6:1-7 ~ Organic Growth of the Early Church (pt. 1)Laura Zielke
 
Failing at Scale - PNWPHP 2016
Failing at Scale - PNWPHP 2016Failing at Scale - PNWPHP 2016
Failing at Scale - PNWPHP 2016Chris Tankersley
 
Using a Canary Microservice to Validate the Software Delivery Pipeline
Using a Canary Microservice to Validate the Software Delivery PipelineUsing a Canary Microservice to Validate the Software Delivery Pipeline
Using a Canary Microservice to Validate the Software Delivery PipelineXebiaLabs
 
Catálogo Elk Sport 2016 2017
Catálogo Elk Sport 2016 2017Catálogo Elk Sport 2016 2017
Catálogo Elk Sport 2016 2017Elk Sport
 

Andere mochten auch (20)

Docker experience @inbotapp
Docker experience @inbotappDocker experience @inbotapp
Docker experience @inbotapp
 
USGS Report on the Impact of Marcellus Shale Drilling on Forest Animal Habitats
USGS Report on the Impact of Marcellus Shale Drilling on Forest Animal HabitatsUSGS Report on the Impact of Marcellus Shale Drilling on Forest Animal Habitats
USGS Report on the Impact of Marcellus Shale Drilling on Forest Animal Habitats
 
Heterogenous Persistence
Heterogenous PersistenceHeterogenous Persistence
Heterogenous Persistence
 
Open Secrets of the Defense Industry: Building Your Own Intelligence Program ...
Open Secrets of the Defense Industry: Building Your Own Intelligence Program ...Open Secrets of the Defense Industry: Building Your Own Intelligence Program ...
Open Secrets of the Defense Industry: Building Your Own Intelligence Program ...
 
Demystifying Security Analytics: Data, Methods, Use Cases
Demystifying Security Analytics: Data, Methods, Use CasesDemystifying Security Analytics: Data, Methods, Use Cases
Demystifying Security Analytics: Data, Methods, Use Cases
 
Adaptive Content Show & Tell - Austin Content
Adaptive Content Show & Tell - Austin ContentAdaptive Content Show & Tell - Austin Content
Adaptive Content Show & Tell - Austin Content
 
How to build a Distributed Serverless Polyglot Microservices IoT Platform us...
How to build a Distributed Serverless Polyglot Microservices IoT Platform us...How to build a Distributed Serverless Polyglot Microservices IoT Platform us...
How to build a Distributed Serverless Polyglot Microservices IoT Platform us...
 
Micro Services - Small is Beautiful
Micro Services - Small is BeautifulMicro Services - Small is Beautiful
Micro Services - Small is Beautiful
 
Combining sentences with the words although and despite
Combining sentences with the words although and despiteCombining sentences with the words although and despite
Combining sentences with the words although and despite
 
Urban legends - PJ Hagerty - Codemotion Amsterdam 2017
Urban legends - PJ Hagerty - Codemotion Amsterdam 2017Urban legends - PJ Hagerty - Codemotion Amsterdam 2017
Urban legends - PJ Hagerty - Codemotion Amsterdam 2017
 
Deploying services: automation with docker and ansible
Deploying services: automation with docker and ansibleDeploying services: automation with docker and ansible
Deploying services: automation with docker and ansible
 
Data Visualization on the Tech Side
Data Visualization on the Tech SideData Visualization on the Tech Side
Data Visualization on the Tech Side
 
Building Awesome APIs with Lumen
Building Awesome APIs with LumenBuilding Awesome APIs with Lumen
Building Awesome APIs with Lumen
 
Acts 6:1-7 ~ Organic Growth of the Early Church (pt. 1)
Acts 6:1-7 ~ Organic Growth of the Early Church (pt. 1)Acts 6:1-7 ~ Organic Growth of the Early Church (pt. 1)
Acts 6:1-7 ~ Organic Growth of the Early Church (pt. 1)
 
Failing at Scale - PNWPHP 2016
Failing at Scale - PNWPHP 2016Failing at Scale - PNWPHP 2016
Failing at Scale - PNWPHP 2016
 
Microservices
MicroservicesMicroservices
Microservices
 
Using a Canary Microservice to Validate the Software Delivery Pipeline
Using a Canary Microservice to Validate the Software Delivery PipelineUsing a Canary Microservice to Validate the Software Delivery Pipeline
Using a Canary Microservice to Validate the Software Delivery Pipeline
 
Selma_CV1
Selma_CV1Selma_CV1
Selma_CV1
 
Catálogo Elk Sport 2016 2017
Catálogo Elk Sport 2016 2017Catálogo Elk Sport 2016 2017
Catálogo Elk Sport 2016 2017
 
Unit I.fundamental of Programmable DSP
Unit I.fundamental of Programmable DSPUnit I.fundamental of Programmable DSP
Unit I.fundamental of Programmable DSP
 

Ähnlich wie Roxar Multiphase Meter

Product data-sheet-mpfm-2600-m-roxar-en-us-170810
Product data-sheet-mpfm-2600-m-roxar-en-us-170810Product data-sheet-mpfm-2600-m-roxar-en-us-170810
Product data-sheet-mpfm-2600-m-roxar-en-us-170810pereiracinthiag
 
Pulp and Paper industry-sensors
Pulp and Paper industry-sensorsPulp and Paper industry-sensors
Pulp and Paper industry-sensorsAllysa Almagro
 
Industrial Level Instrument Selection Guide
Industrial Level Instrument Selection GuideIndustrial Level Instrument Selection Guide
Industrial Level Instrument Selection GuideIves Equipment
 
Flow Instruments for Test and Measurement Selection Guide by Badger Meter
Flow Instruments for Test and Measurement Selection Guide by Badger MeterFlow Instruments for Test and Measurement Selection Guide by Badger Meter
Flow Instruments for Test and Measurement Selection Guide by Badger MeterThompson Equipment Company
 
Water and wastewater brochure badger meter
Water and wastewater brochure badger meterWater and wastewater brochure badger meter
Water and wastewater brochure badger meterENVIMART
 
Open Channel and Panel Meters
Open Channel and Panel Meters Open Channel and Panel Meters
Open Channel and Panel Meters Dwyer Instruments
 
GUIDED WAVE RADAR TECHNOLOGY
GUIDED WAVE RADAR TECHNOLOGYGUIDED WAVE RADAR TECHNOLOGY
GUIDED WAVE RADAR TECHNOLOGYBenjamin Kyalo
 
Brochure Measurement Solutions for the Water and Wastewater Industries Ver#2
Brochure Measurement Solutions for the Water and Wastewater Industries Ver#2Brochure Measurement Solutions for the Water and Wastewater Industries Ver#2
Brochure Measurement Solutions for the Water and Wastewater Industries Ver#2AMETEK STC
 
Industrial monitoring and control systems using andriod application
Industrial monitoring and control systems using andriod applicationIndustrial monitoring and control systems using andriod application
Industrial monitoring and control systems using andriod applicationAvinash Vemula
 
WFS Summary Presentation Apr16 V1
WFS Summary Presentation Apr16 V1WFS Summary Presentation Apr16 V1
WFS Summary Presentation Apr16 V1Mike Theobald
 
Vacuum precision positioning systems brochure
Vacuum precision positioning systems brochureVacuum precision positioning systems brochure
Vacuum precision positioning systems brochureJohn Mike
 
Flow, Pressure & Vapor Instrumentation
Flow, Pressure & Vapor InstrumentationFlow, Pressure & Vapor Instrumentation
Flow, Pressure & Vapor InstrumentationMiller Energy, Inc.
 
Micronics Clamp On Flow Meter Portaflow 220 - Spec Sheet
Micronics Clamp On Flow Meter Portaflow 220 - Spec SheetMicronics Clamp On Flow Meter Portaflow 220 - Spec Sheet
Micronics Clamp On Flow Meter Portaflow 220 - Spec SheetThorne & Derrick UK
 
Trace Moisture Analyzer For Industrial Use
Trace Moisture Analyzer For Industrial UseTrace Moisture Analyzer For Industrial Use
Trace Moisture Analyzer For Industrial UseMiller Energy, Inc.
 
Nivelco Instrumentation for Chemical and Pharmaceutical Industries
Nivelco Instrumentation for Chemical and Pharmaceutical IndustriesNivelco Instrumentation for Chemical and Pharmaceutical Industries
Nivelco Instrumentation for Chemical and Pharmaceutical IndustriesArjay Automation
 
RBFM Clamp-on Ultrsonic Flow Meter/ Heat Meter Catalog
RBFM Clamp-on Ultrsonic Flow Meter/ Heat Meter CatalogRBFM Clamp-on Ultrsonic Flow Meter/ Heat Meter Catalog
RBFM Clamp-on Ultrsonic Flow Meter/ Heat Meter Catalogjessy Lee RB Flowmeter
 

Ähnlich wie Roxar Multiphase Meter (20)

Product data-sheet-mpfm-2600-m-roxar-en-us-170810
Product data-sheet-mpfm-2600-m-roxar-en-us-170810Product data-sheet-mpfm-2600-m-roxar-en-us-170810
Product data-sheet-mpfm-2600-m-roxar-en-us-170810
 
Pulp and Paper industry-sensors
Pulp and Paper industry-sensorsPulp and Paper industry-sensors
Pulp and Paper industry-sensors
 
Industrial Level Instrument Selection Guide
Industrial Level Instrument Selection GuideIndustrial Level Instrument Selection Guide
Industrial Level Instrument Selection Guide
 
Flow Instruments for Test and Measurement Selection Guide by Badger Meter
Flow Instruments for Test and Measurement Selection Guide by Badger MeterFlow Instruments for Test and Measurement Selection Guide by Badger Meter
Flow Instruments for Test and Measurement Selection Guide by Badger Meter
 
Water and wastewater brochure badger meter
Water and wastewater brochure badger meterWater and wastewater brochure badger meter
Water and wastewater brochure badger meter
 
Open Channel and Panel Meters
Open Channel and Panel Meters Open Channel and Panel Meters
Open Channel and Panel Meters
 
Measurement Solutions for the Water and Wastewater Industries
Measurement Solutions for the Water and Wastewater IndustriesMeasurement Solutions for the Water and Wastewater Industries
Measurement Solutions for the Water and Wastewater Industries
 
GUIDED WAVE RADAR TECHNOLOGY
GUIDED WAVE RADAR TECHNOLOGYGUIDED WAVE RADAR TECHNOLOGY
GUIDED WAVE RADAR TECHNOLOGY
 
Brochure Measurement Solutions for the Water and Wastewater Industries Ver#2
Brochure Measurement Solutions for the Water and Wastewater Industries Ver#2Brochure Measurement Solutions for the Water and Wastewater Industries Ver#2
Brochure Measurement Solutions for the Water and Wastewater Industries Ver#2
 
Industrial monitoring and control systems using andriod application
Industrial monitoring and control systems using andriod applicationIndustrial monitoring and control systems using andriod application
Industrial monitoring and control systems using andriod application
 
Level and Pressure Instrumentation for Pulp & Paper Production
Level and Pressure Instrumentation for Pulp & Paper ProductionLevel and Pressure Instrumentation for Pulp & Paper Production
Level and Pressure Instrumentation for Pulp & Paper Production
 
WFS Summary Presentation Apr16 V1
WFS Summary Presentation Apr16 V1WFS Summary Presentation Apr16 V1
WFS Summary Presentation Apr16 V1
 
Vacuum precision positioning systems brochure
Vacuum precision positioning systems brochureVacuum precision positioning systems brochure
Vacuum precision positioning systems brochure
 
Flow, Pressure & Vapor Instrumentation
Flow, Pressure & Vapor InstrumentationFlow, Pressure & Vapor Instrumentation
Flow, Pressure & Vapor Instrumentation
 
Shell Subsea Control.pdf
Shell Subsea Control.pdfShell Subsea Control.pdf
Shell Subsea Control.pdf
 
Micronics Clamp On Flow Meter Portaflow 220 - Spec Sheet
Micronics Clamp On Flow Meter Portaflow 220 - Spec SheetMicronics Clamp On Flow Meter Portaflow 220 - Spec Sheet
Micronics Clamp On Flow Meter Portaflow 220 - Spec Sheet
 
Trace Moisture Analyzer For Industrial Use
Trace Moisture Analyzer For Industrial UseTrace Moisture Analyzer For Industrial Use
Trace Moisture Analyzer For Industrial Use
 
Nivelco Instrumentation for Chemical and Pharmaceutical Industries
Nivelco Instrumentation for Chemical and Pharmaceutical IndustriesNivelco Instrumentation for Chemical and Pharmaceutical Industries
Nivelco Instrumentation for Chemical and Pharmaceutical Industries
 
RBFM Clamp-on Ultrsonic Flow Meter/ Heat Meter Catalog
RBFM Clamp-on Ultrsonic Flow Meter/ Heat Meter CatalogRBFM Clamp-on Ultrsonic Flow Meter/ Heat Meter Catalog
RBFM Clamp-on Ultrsonic Flow Meter/ Heat Meter Catalog
 
2013 tms gvu hyprop
2013 tms gvu hyprop2013 tms gvu hyprop
2013 tms gvu hyprop
 

Roxar Multiphase Meter

  • 1. Roxar Multiphase meter MPFM 2600 - Turning information into value This presentation is provided for information purposes only. It should not be used or considered as an offer to sell or a solicitation of an offer to buy any securities. Any opinions expressed are subject to change without prior notice. Although all reasonable care has been taken to ensure that the information herein is not misleading, Roxar ASA makes no representation or warranty expressed or implied as to its accuracy or completeness. Neither Roxar ASA, its employees, nor any other person connected with it, accepts any liability whatsoever for any direct or consequential loss of any kind arising out of the use or reliance on the information in this presentation. This presentation is prepared for general circulation and general information. December 2009
  • 2. Roxar’s Mission statement: Our mission is simply: TO ENABLE OUR CUSTOMERS TO MAXIMIZE RESERVOIR PERFORMANCE Roxar is the industrial inventor and pioneer of multiphase metering and sand monitoring, and a leading global supplier of real-time measurements solutions for production optimization, enhanced oil recovery and flow assurance. Roxar’s instrument design philosophy is based upon the following principles: - Keep it simple - Build in redundancy - Maximize use of direct measurements
  • 3. What is a multiphase meter - A non-intrusive multiphase flow measurements device that provides real-time and continuous three-phase measurements  Measures • fraction and velocity of oil • fraction and velocity of water • fraction and velocity of gas  Outputs • Oil rate • Water rate • Gas rate
  • 4. Roxar Multiphase meter applications Traditional layout using separators  Complex piping and valve arrangement  Limited / periodic testing only
  • 5. Roxar Multiphase meter applications Using inline Multiphase meters  Real-time and continuous monitoring Excluding test separator on new/upgrade installations  Early detection of water/gas breakthrough  Improved well control  Reduction in Opex and Capex Ultimately - Optimize the lifetime of the field
  • 6. Roxar Multiphase and Wetgas meters Subsea meters Topside meters Gamma Non-gamma Gamma Wetgas
  • 7. Multiphase Meters Today  A growing market  Significant take-up  A vital component of field production (production monitoring, individual well testing, production allocation & reservoir monitoring) 7
  • 8. 55 operators in 72 countries
  • 9. Recent Customers – Multiphase and Wetgas meters
  • 10. The industrial inventor of multiphase metering Roxar started the development of multiphase metering technology in 1984 and can celebrate 25 years of innovation!
  • 11. From 1st to 3rd Generation The first generation of multiphase meters:  Assumed homogenous flow conditions  Incorporated models based on a single flow velocity The second generation of multiphase meters:  Dual cross correlation (individual Liquid and Gas velocity measurements)  Sophisticated signal processing  The dual velocity model is a well suited model, but still a simplification of very complex flow patterns 11
  • 12. 2nd generation MPFM Real system Dual velocity system DP22 electrode 2 volumes system - Large bubble volume - Dispersed phase Multiphase / 2 velocities multi-velocity - Large bubble velocity - Dispersed phase velocity
  • 13. Witness a step-change in technological sophistication 13
  • 14. Roxar MPFM 2600 – key elements Simple, light-weight design, 80% weight reduction and half the length compared to the previous generation  The image shows the relative difference in size for a typical 3” meter  Weight: 550 vs.110 kg  Length: 1300 vs. 650 mm Added value:  Simple installation  Easy handling  Greater flexibility
  • 15. Roxar MPFM 2600 – key elements Field replaceable insert venturi  Four pressure tapping’s and ring chamber improves accuracy and stability (same design as for subsea meters)  A field replaceable insert venturi sleeve Added value:  Extended service life  Extended operating range – can easily be replaced in the field  Removes uncertainties when sizing meters based on predicted production forecasts
  • 16. Roxar MPFM 2600 – key elements Compact, integrated measurement solution for pressure, differential pressure and temperature  Multivariable transmitter, Rosemount 3095MA  Enables highly sensitive, accurate, DP, P and T measurements  No impulse lines Added value:  Combines the best features from remote seal solutions and open impulse tubing  Limits the potential for clogging  Easy field replacement
  • 17. Roxar MPFM 2600 – key elements Non-radioactive version covering most operating conditions - gamma version for special applications and high GVF  Base version is non-gamma – suited for installations < 95% GVF Upgrade with mini- gamma  For applications with very high GVF system (>95%), the gamma version is recommended Added value:  No source handling, paper work or import licenses needed  The gamma system can easily be retrofitted if and when flow conditions so dictate
  • 18. Roxar 2600 class – key elements New compact gamma system for special and high GVF applications  Developed by Roxar in collaboration with partners. Patent pending  Source holder and detector specially designed for the application  Designed and qualified according to ISO 7205 and ISO 2919  ISO 13628-2006 requirements used for temperature and vibration testing
  • 19. Roxar 2600 class – key elements New compact gamma system Source  Isotope: Cs-137  Nominal activity: 1mCi  Maximum surface dose-rate: 5 µSv/hour  Half-life: 30.2 years  Source capsule: double encapsulation
  • 20. Roxar 2600 class – key elements New compact gamma system Detector  Digital signal transmission  Automatic stabilization integrated in detector  Internal temperature measurement  Extended diagnostics
  • 21. Roxar 2600 class – key elements Benefits of the new gamma system  Source and detector closer to the flow – improved measurements  Build-in stability functionality – measurements not affected by temperature fluctuations and aging of the detector  Reduced weight and length – simplifies installation on site  Digital signal transmission – allows for improved data transfer and diagnostics
  • 22. Introducing Roxar Zector technology  Key components of Roxar’s Zector technology: -DP26 electrode geometry -New impedance electronics -Voxel based signal processing (4D pixels)  Voxel based signal processing and DP26 electrode geometry provides: - multiple flow velocities - near wall measurements  The new technology operates seamlessly in both oil- and water- continuous flow which results in rapid detection of regime changes
  • 23. Roxar MPFM 2600 – key elements Roxar Zector® technology Key components:  DP26 electrode geometry  New impedance electronics  Advanced signal processing Replaces the capacitance and inductive electronics, and uses the same set of electrodes Measures both components simultaneously - operates seamlessly in both oil- and water-continuous flow Analog Devices Blackfin® Processor - specially developed for real time image processing and streaming media application
  • 24. Roxar MPFM 2600 – key elements Roxar Zector® technology  Traditional bulk- measurement  Near-wall-measurement  Rotational measurement Added value: Improved measurement uncertainty Scale / Wax detection / correction Asymmetric flow detection Multiple velocity measurements
  • 25. Roxar MPFM 2600 – key elements Roxar Zector® technology  Traditional bulk- measurement  Near-wall-measurement  Rotational measurement Added value: Improved measurement uncertainty Scale / Wax detection / correction Asymmetric flow detection Multiple velocity measurements
  • 26. 2nd generation MPFM Real system Dual velocity system Dp22 electrode 2 volumes system - Large bubble volume (r, l) - Dispersed phase Multiphase / 2 velocities multi-velocity - Large bubble velocity - Dispersed phase velocity
  • 27. Roxar MPFM 2600: 3rd generation Real system 4D voxel system DP26 electrode system • Asymmetric Large bubble volume • Variable dispersed phase volumes Multiphase / Multi-velocity • Near wall measurement volumes • Large bubble velocity • Dispersed phase velocity • Velocities per sector
  • 28. Technology comparison - MPFM 1900VI vs. MPFM 2600 Measurement MPFM 1900VI MPFM 2600 Mixture density and GLR Single Energy Gamma V V Fraction measurements Permittivity / Capacitance V V Conductivity / Inductance V Conductivity / Conductance V 2-plane Electrodes V V 6-plane Electrodes V Flow Venturi V V Insert sleeve V Cross correlation V V Primary measurements Pressure V V Differential pressure V V Temperature V V 25 years of experience in multiphase metering – the MPFM 2600 is next step
  • 29. Specifications Qualification testing  The Roxar Multiphase meter 2600 has been extensively tested, both statically and dynamically, including: - Pressure and temperature cycling - Calibration and sensitivity testing - Flow testing  The loop testing has demonstrated superior performance for measurement of all three phases  As a result, the operating envelope has been widened, and uncertainty is reduced
  • 30. Flow loop performance testing December 2008 -“Measurement accuracy appears consistent June / July 2009 across water and oil continuous regimes” -“Overall excellent performance of the meter” -“In a comparison against the manufacturer’s performance specification, all of the meters individual measurements were within the current published uncertainty specification” - “The meter performed extremely well on liquid flow, gas flow and liquid water cut”
  • 31. Results - Flow loop testing December 2008
  • 32.
  • 33. Serial number: 1431.06 + 1676.08 Qliquid Date: 19. December 2008 Deviation in Liquid Flow Rate vs: Gas Volume Fraction Project : 30075 Dstar 3.0 '' - Roxar Multiphase meter 15 10 5 Deviation Liquid (rel %) 0 0 15 30 45 60 75 90 -5 -10 -15 GVF % Combined Uncertainty - Roxar Multiphase meter
  • 34. Serial number: 1431.06 + 1676.08 Date: 19.December 2009 Gas Flow Rate Project : 30075 Dstar Multiphase meter vs. Reference 150 125 Qgas Multiphase meter [m3/h] 100 75 50 25 0 0 25 50 75 100 125 15 Qgas Reference [ m3/h] Org. Qgas oilcont MPFM2600 Org. Qgas watercont MPFM2600 10%
  • 35. Serial number: 1431.06 + 1676.08 Qgas (Deviation in Gas Flow Rate vs. Gas Volume Fraction) Date: 19. December 2008 3.0 '' - Roxar Multiphase meter Project : 30075 Dstar 35 25 15 Gas deviation (rel %) 5 0 15 30 45 60 75 90 -5 -15 -25 -35 GVF (%) Combined Uncertainty - Roxar Multiphase meter
  • 36. Serial number: 1431.06 + 1676.08 Date: 19.December 2009 Watercut Project : 30075 Dstar Multiphase meter vs. Reference 100 90 80 70 Watercut - MPFM [%] 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 10 Watercut - Reference [%] 5%
  • 37. Serial number: 1431.06 + 1676.08 Watercut Date: 19.December 2009 Deviation in WC vs. Gas Volume Fraction Project : 30075 Dstar 3.0 '' - Roxar Multiphase meter 15 10 5 Absolute deviation % 0 0 15 30 45 60 75 90 -5 -10 -15 GVF % Org. WLR MPFM2600 Combined Uncertainty - Roxar Multiphase meter
  • 38. Results - Flow loop testing June / July 2009
  • 39. NEL Test Results: Multiphase Results Liquid Flow Rate Multiphase meter vs. Reference 50 40 Qliq Multiphase meter [m3/h] 30 20 10 Qliq oilcont. Qliq w atercont. +/- 5 % 0 0 10 20 30 40 50 Qliq Reference [m3/h] 39
  • 40. NEL Test Results: Multiphase Results Deviation in Liquid Flow Rate vs: Gas Volume Fraction MPFM2600 15 10 5 Deviation Liquid (rel %) 0 0 15 30 45 60 75 90 -5 -10 Org. Qliq_Oilcont. Org. Qliq_Watercont. Combined Uncertainty - Roxar Multiphase meter -15 GVF %
  • 41. NEL Test Results: Multiphase Results Gas Flow Rate Multiphase meter vs. Reference 210 200 190 180 170 160 150 140 eter [m3/h] 130 120 gas ultiphase m 110 100 90 Q M 80 70 60 50 40 30 Qgas oilcont 20 Qgas w atercont 10 +/- 8 % 0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 Qgas NEL Reference [ m3/h]
  • 42. NEL Test Results: Multiphase Results Deviation in Gas Flow Rate vs. Gas Volume Fraction MPFM2600 30 25 20 15 10 Gas deviation (rel %) 5 0 0 15 30 45 60 75 90 -5 -10 -15 -20 Qgas_Oilcont -25 Qgas_Watercont Combined Uncertainty - Roxar Multiphase meter -30 GVF (%)
  • 43. NEL Test Results: Multiphase Results Watercut 100 Multiphase meter vs. Reference 90 80 70 atercut - MPFM [%] 60 50 W 40 30 20 10 WLR_Oilcont. WLR_Watercont. +/- 5 % 0 0 10 20 30 40 50 60 70 80 90 100 Watercut - Reference [%]
  • 44. NEL Test Results: Multiphase Results Deviation in WC vs. Gas Volume Fraction MPFM 15 10 5 Absolute deviation% 0 0 15 30 45 60 75 90 -5 -10 WLR-w ater cont. WLR oil cont. Combined Uncertainty - Roxar Multiphase meter -15 GVF %
  • 45. Wet gas test – TUV NEL •2 phase test version based on PVT input (density and LGR) •Based on Chisholm wet gas model + Roxar calibration model
  • 46. Wet gas test – TUV NEL
  • 47. Wet gas sensitivity – TUV NEL •The permittivity of the wet gas was measured using the MPFM 2600 •The TUV NEL loop was operated on condensate with no water • It is possible to calculate the expected sensitivity to a change in water fraction based on the sensitivity in the permittivity measurements • A change in GVF from 99.55% to 99.79% could easily be measured, resulting in a change in permittivity of -0.00265 abs • This corresponds to a water fraction sensitivity of +/-0.018% abs
  • 48. New Performance Specification Improved uncertainty specification for all three phases Uncertainty specification for both Multiphase and Wetgas mode 0-100 % GVF and 0-100 % WLR Same specification for both oil and water continues flow 48
  • 49. Roxar Fieldwatch Are your investments working at peak performance? How can you ensure:  the best performance of the multiphase meter when installed?  getting remote service during the life of the multiphase meter?  the best access of data from the multiphase meter?  avoiding data overflow from multiphase meters? Answer: Roxar Fieldwatch  Roxar Fieldwatch is the instrument interface software for all RFM instruments  Set up of instruments with full service console capabilities  Storage of large amount of data  User interface through Roxar Field explorer  Industry standard interfaces with external networks
  • 50. Why Roxar Fieldwatch  When installing the state-of-the-art Roxar Multiphase meter, Roxar Fieldwatch is the best software to store, view and most importantly service this during its operation Roxar Field Many user of data Explorer simultaneously Roxar Field One server installed server on site Roxar Field interfaces Roxar Multiphase Many meters connected meter simultaneously
  • 51. Roxar Fieldwatch - Features  Interface with third party network systems to connect/interface with the Roxar Multiphase meter  Specialized viewing features for Roxar Multiphase meter  Data storage  Data display  Data transfer  Service Console
  • 52. Installation  Typical communication set-up Safe area Hazardous area Roxar Fieldwatch Flow Computer Distributed Control System
  • 53. Installation  Typical communication set-up  1. MPFM 2600  2. Flow computer, EExd
  • 54. X-Ray Based Densitometer Nuclear gamma-sources traditionally required for optimal MPFM measurements (high accuracy and full GVF range). X-ray based densitometer provides the same or higher measurement accuracy without the radioactive isotope. 102 100 Special requirements concerning 98 storage, importing, handling during GVF 96 MPFM FluorX installation, the return of used 94 NEL ref sources etc avoided. 92 90 0 5 10 15 20 25 30 Test point The obvious benefit when using an X-ray source is the possibility to switch off the radiation! 54
  • 55. Today…Tomorrow… Welcome to what’s next, welcome to the future Roxar Multiphase meter MPFM 2600 Built on Zector® Technology This presentation is provided for information purposes only. It should not be used or considered as an offer to sell or a solicitation of an offer to buy any securities. Any opinions expressed are subject to change without prior notice. Although all reasonable care has been taken to ensure that the information herein is not misleading, Roxar ASA makes no representation or warranty expressed or implied as to its accuracy or completeness. Neither Roxar ASA, its employees, nor any other person connected with it, accepts any liability whatsoever for any direct or consequential loss of any kind arising out of the use or reliance on the information in this presentation. This presentation is prepared for general circulation and general information.