1. Test Report No.BLR/H(RO)/13/001516
Dated 2013-11-27
Applicant SILENCE
2/1A MONOHAR PUKUE 2ND LANE KOLKATA-700029
:
Shampa Bakshi:Attention
Tested Sample Received on 2013-11-18 2:22 pm:
Test Period : 2013-11-19 to 2013-11-27
Sample A:METAL PARTS CLAPS in Color : -Sample Description :
Part No. 3000920 B:
Buyer Name CTM ALTAMORERCATO:
Addtional Info. SUPPLIER NAME: SILENCE:
Objetives Of Examination To test Nickel Release as per EN 1811:
Note : The submitted Samples were not drawn by laboratory.
Conclusion : Refer Results
Sudhakar Bhat
Authorized Signatory
Das Sanjay Kumar
Report Reviewer
Authorised By
Please contact :
For any technical issues : Sudhakar Bhat at Sudhakar.Bhat@tuv-sud.in
For any complaint : Kaur, Ramjit at Ramjit.Kaur@tuv-sud.in.
Note: The test report is electronically generated. Hence original signature is not required.
Note : (1) General Terms & Conditions as mentioned overleaf, (2) The results relate only to the items tested, (3) the test report shall not be reproduced except
in ful without the written approval of the laboratory (4) For details of the accredited scope, please contact laboratory or accreditation body website
Regd. Office:
TUV SUD South Asia Pvt. Ltd.
Off Saki Vihar Road, Saki
naka, Andheri (East),
Mumbai-400072. India
Phone :080 67458000
Fax :080 67458058
E-Mail :Sanjay.Das@tuv-sud.in
Url : www.tuv-sud.in/softlines
ControlNo:15310221.181113.005
Laboratory:
TÜV SÜD South Asia Pvt. Ltd.
No. A. 151, 2nd C Main, 2nd Stage, Peenya Industrial
Estate, Bangalore - 560 058. India.
BANGALORE-560058,Karnataka,India Page 1 of 2
2. Test Report No.BLR/H(RO)/13/001516
Dated 2013-11-27
Tests Subject Description:
MATERIAL DESCRIPTIONCODE NO. RESULTPHOTOGRAPHSAMPLE NO.
PASSA - METAL PARTS CLAPS
Test Result
NICKEL RELEASE
(EN 1811 : 2011, Nickel release is measured in metallic parts as per EN 1811 if the article is not coated. If the article is coated, the coating is
removed as per the procedure described in method EN 12472)
1.0
A
(µg/cm²/week)
Sample Details Claps
Area of Sample Tested (cm²) 6.10
Volume of the test solution used (ml) 7
Results (µg/cm²/week Not Detected
Compliance / Noncompliance Compliance
-
-
-
-
-
Limit Max.
Limit of Quantification: 0.05 µg/cm²/week
Requirement Limit:-
Migration limit 0.5 µg/cm²/week:
An article with prolonged contact skin will be deemed to be non-compliance when the nickel release value is greater than or
equal to 0.88 µg/cm²/week
Migration limit 0.2 µg/cm²/week
An article with pierced body contact & baby articles will be deemed to be non-compliance when the nickel release value is
greater than or equal to 0.35 µg/cm²/week
- END OF TEST REPORT-
Regd. Office:
TUV SUD South Asia Pvt. Ltd.
Off Saki Vihar Road, Saki
naka, Andheri (East),
Mumbai-400072. India
Phone :080 67458000
Fax :080 67458058
E-Mail :Sanjay.Das@tuv-sud.in
Url : www.tuv-sud.in/softlines
ControlNo:15310221.181113.005
Laboratory:
TÜV SÜD South Asia Pvt. Ltd.
No. A. 151, 2nd C Main, 2nd Stage, Peenya Industrial
Estate, Bangalore - 560 058. India.
BANGALORE-560058,Karnataka,India Page 2 of 2