Firestop penetrations are the most common code violation found by commercial building inspectors. Avoid trouble by determining the maximum number of cables a building may need. Don’t forget to plan penetrations needed to allow all the low voltage cabling required in the building. Use Future Proof Plates to centralize, install and maintain firewall penetrations made by telecomm installers for the life of a new building.
11. KEEP YOUR PLANNING SIMPLE
Use Future Proof Plates to centralize,
install and maintain firewall
penetrations made by telecomm
installers for the life of a new building.
12. FPP’s allow cable bundles to be in
designated positions by design,
allowing for ease of
maintenance by
centralizing all
potential
penetrations.
13. FPP's can be
designed with
multiple holes for
all the different
types of cabling to
be installed, smoke
sealed and fire
stopped.
14. FPP's are sealed with
firestop caulk behind
the pairs of plates
with a bead of caulk
around each of the
holes on both sides of
the firewall.
The key here is to only make the
holes in the firewall as needed.
15. Designers can plan enough
holes in FPP’s for future
cabling and avoid the lack of
planning pitfalls for the life
of the building, if properly
maintained.
16. FPP's can be used with any type of
mechanical sleeve system on the market
today. All FPP‘s are powder coated RED
and are available with any number of
different configurations to be able to
group the cable media.
17. Because firestop
sleeve systems are
not allowed to be left
open and unattended,
make sure to use
Smooth Endcaps to
seal the ends of empty
sleeves.
18. IDENTIFY YOUR BARRIER RATING
Make sure to identify your barrier
ratings and label them accordingly for
planning future penetrations.
19. Proper documentation with alpha numeric
identification on a digital photo could save
you a lot of trouble at inspection time.
20. Label your fire-rated barrier in multiple
locations and be sure to post any F - T - L
ratings.
21. TRAIN YOUR PEOPLE
Its important that your own people
know how to properly install and
maintain your building’s firestop
system.
22. HOW TO FUTUREPROOF YOUR
CABLE FIRESTOP PENETRATIONS
• Establish a S.O.P.
• Have a Cabling Plan for the Building
• Use Future Proof Plates to Group Existing and Future
Firewall Penetrations
• Label your Firewall with its Barrier Rating
• Train Your Installers
• Call us for Assistance- 251-751-8774
23. Visit our websitefor more firestop products
and completeinstallation pictorials.
https://www.uniquefirestop.com/