Körting ICE Condensation
Vacuum System
for edible oil applications
Like all vegetable oil processing vacuum sys-
tems, Körting ICE Condensation Vacuum
Systems are able to operate an oil deodoris-
ing plant in the range between 1 - 4 mbar by
extracting sparging steam and air.
In contrast to conventional vacuum systems,
Körting ICE Condensation Vacuum Systems
allow the process vapour to be condensed
close to the operation pressure of the deodor-
iser (rather than having to compress it first with
steam jet boosters then condense it to liquid).
At a.m. pressures, condensation occurs be-
tween -20 °C and -5 °C, so in order to operate
such condenser, a refrigerant to be circulated
through its tubes at temperatures down to
-30 °C is required.
This results in the steam condensing as a solid
ice coating outside of the condenser tubes.
The ice layer has to be regularly removed by
melting. In order to operate in a continuous
cycle, Körting ICE Condensation Vacuum Sys-
tems utilise two parallel ice condensers which
are operated alternately. One ice condenser is
in operation (being charged) whereas the other
one is heated with hot water vapour to melt the
ice layer.
At preset intervals, the clean, ice free condenser
is pre-cooled before it is then switched back into
the circuit whereas the other is disconnected to
begin its melting cycle.
The sequence is designed in such a way that the
vacuum level is not increased when switching
over from one condenser to the other.
ICE Condensation Vacuum System
In the today's market, Körting ICE Condensation Vacuum
System make sense!
Ice condensation block completely assembled in the workshop
Assembly of an ice condensation block at site
Significant energy
savings with virtually zero
environmental pollution
Körting ICE Condensation Systems have
two principle advantages:
•	The refrigerated coolant and the polluted sparging steam are strictly separated, which pro-
tects the environment considerably.
•	The coolant compressor operates at a higher efficiency compared to steam jet boosters of a
conventional vacuum system. Therefore, energy and operarting costs are saved significantly.
The original concept was proposed by G. B. Martinenghi (1964) but at that time the high capital
cost of the system compared to conventional vacuum systems proved uneconomical.
Today with increasing energy costs and strict environmental emission controls (waste
water, air pollution), the ice condensation system is the most economic vacuum system for this
application.
Körting ICE Condensation Vacuum Systems are based on many years of experience with a lot
of installations world wide since 1988.
It is computer controlled and designed to be both:
Simple and reliable in operation.
Ice condensation block completely installed at site
Front view of an ice condensation unit
cooling
water
air evacuation group
liquid ring
vacuum pump
heating
steam
closed
open
ice condenser A PI
condensate (clean)
TIC
melting
vessel MIN
MAX
ammonia
separator
PIC
from deodoriser
spraying
pump
ammonia
compressor
bleed
expansion
valve
evaporative condenser
(ammonia condenser)
Fan
fresh
water
ice condenser B
waste water
(highly poluted)
condensate
pump
TI
loading
melting
precooling
loading
melting
precooling
waste water
(slightly poluted)
gas outlet
cooling water
cooling
water
ejector
(2nd stage)
ejector
(1st stage)
condenser
air evacuation
PI
PI
PI
PI
Flow chart of an Körting ICE Condensation Vacuum System
Condensing
The sparging steam from the deodoriser, pol-
luted by fatty acids and other impurities and
fatty substances, is alternately supplied to
the ice condenser A or B. High performance
butterfly valves are used to isolate the ice
condenser from the process during melt-
ing. The condenser being charged is kept at
low temperature by circulating the refrigerant
through the tubes. The refrigerant is conveyed
in a liquid state from the refrigerant separator
and evaporated within the tubes of the con-
denser by absorbing of the condensation heat
of the sparging steam.Typically, this process is
regulated to produce surface temperatures of
around -15 °C to -25 °C on the tubes.
This is below the condensation temperature of
the sparging steam drawn from the deodoriser
so the steam together with most of its impuri-
ties is condensed on the outside of the tubes
as a coating of ice mixed with fatty crystals.
Melting
After a loading time which, according to the
design, may be between one and two hours
the process flow is switched to the other ice
condenser. The charged ice condenser (now
with its cooling elements thoroughly coated
with ice) is entirely separated from the deodor-
iser and heated to approx. 60 °C to 80 °C with
vapour originating from the polluted conden-
sate in the heated melting vessel. The molten
ice which is a mixture of water, oil and fatty
substances runs off from the tubes and back
into the melting vessel.
How do Körting ICE Condensation Vacuum
System work?
The essential elements of the plant are illustrated in the figure above. In this example, ice condenser B
is in use (being charged), ice condenser A is in its melting cycle.
condensate pump
rupture
disc
ice condensers
compressor
refrigerant
gas
inlet
cooling
water
condensate
to the
ammonia
condenser
from the
ammonia
separator
liquid ring vacuum pump
atmosphere
gas outlet
over flow
heating
steam
melting vessel
condensate
air evacuation group
cooling
water
gas outlet
evaporative
condenser
cleaning
connection
cooling
water
fresh
water
motive
steam to the
ammonia
compressor
motive
steam
air
evacuation
safety
valve
ammonia
separator
rupture disc
from the
evaporative
condenser
to the
refrigerant
separator
bleed
from the
refrigerant
compressor
deodoriser
waste
water
scrubber
Condensate discharge
The surplus liquid from the
melting vessel which contains
most of the impurities of the origi-
nal sparging steam is discharged
from the melting vessel by a con-
densate pump.
Steam jet ejectors
In order to evacuate all non-
condensables from the ice con-
densers, a small 2-stage steam
jet ejector vacuum group com-
bined with a liquid ring vacuum
pump is used. Cooling water for
the interconnected small surface
condenser as well as ejectors
and the liquid ring vacuum pump
will be kept clean. Only the small
amount of condensate leaving the
small surface condenser is slightly
polluted and will leave the system
at the separator of the liquid ring
vauum pump. At this point the ex-
hausted gas of the process is also
discharged to the atmosphere.
Coolant refrigeration
To minimise the maintenance
costs and for high operating reli-
ability, the Körting ice condensation
vacuum system operates with
twin-shaft screw compressors
(refrigerant compressor).
Typical installation of an ICE Condensation Vacuum System at an oil deodorising column
2-stage steam jet vacuum ejectors
with shell and tube condenser
Screw compressor for refrigeration
Körting ICE Condensation Vacuum Systems
produce nearly no pollutants. This is principally
based on the fact that the cooling water is kept
strictly separated from the condensate of the
polluted sparge steam.
As condensation takes place at low tempera-
ture and at the pressure level in the deodor-
iser, the melted condensate flowing from ice
condenser A and B is undiluted and highly
concentrated (almost 100 % of the high-boiling
oil components, i.e. fatty acids, which are
exhausted during deodorisation can be found
in condensate).
Only some low-boiling substances such as
aldehydes and ketones are exhausted from
the ice condensers by the steam jet ejectors
together with the non-condensable gas.
The motive flow of the ejectors as well as the
condensable parts of the suction flow are con-
densed in a downstream surface condenser.
There is no contact with the cooling water.
For the atmospheric stage of the air evacuation
unit, a liquid ring vacuum pump is used. To re-
move the condensation and compression heat,
the service water (polluted with low-boiling oil
substances) is passed through a heat exchang-
er in a closed loop so that no oil substances
may enter the cooling water.
Non condensable gases from the process and
the leakage air, which enters the deodoriser, is
polluted with low-boiling oil substances. This
gas mixture is the only exhaust flow discharged
from the unit by means of the liquid ring vacu-
um pump via the liquid separator. This exhaust
gas can be treated by combustion in a steam
boiler or in a biological filter plant.
Mechanical vacuum pumps (roots blowers)
can be used instead of the steam jet vacuum
ejectors. However, this is generally not recom-
mended because mechanical pumps are much
more susceptible to failures.
Melting vessel of a Körting ICE Condensation Vacuum System
Molten condensate in the melting vessel
Why do Körting ICE Condensation Vacuum Systems produce
virtually zero environmental pollution?
Körting ICE Condensation Vacuum Systems save money!
The figure below illustrates the typical payback
time for the investment of a Körting ICE Conden-
sation Vacuum System compared to a steam
jet vacuum ejector system with direct contact
condensation. The graph is calculated for a
condensation pressure of 1.5 mbar which cor-
responds to a deodoriser pressure of around
2.5 mbar and a cooling water inlet temperature
of max. 33 °C. The graph shows that the
payback time depends on the oil production
capacity, based on fixed prices for steam,
electricity, cooling water and waste water. The
bigger the oil production capacity (the higher
the condensation rate of the ice condensation
vacuum system), the shorter the payback time.
If the steam price (for motive steam of the
comparable steam jet vacuum ejector system)
is high, the payback time of the Körting ICE
Condensation Vacuum System will be consider-
ably reduced.
The comparison between a Körting ICE Condensation Vacuum System and a conventional steam jet vacuum
ejector system as well as the operating costs depend on two principal factors:
•	Based on standard specific costs for steam and electricity the total operating costs for a Körting ICE Con-
densation Vacuum System are much lower compared to a conventional steam jet vacuum system.
•	Investment costs are higher – Körting ICE Condensation Vacuum Systems require higher initial investment
compared to other vacuum producing equipments used in the processing of edible oils and fats but they
offer a short payback time.
→
Operating costs of ice condensation vacuum system
Operating costs for steam jet vacuum system
Investment cost difference
Index
oil production capacity (TPD)
100 200 300 400 500 600 700 800
0
1
2
3
4
5
6
7
8
9
10
11
12
Example
For an oil production capacity
of 600 tons/day and a motive
steam price of 25 Euro/ton,
electric power of 0.1 Euro/kWh
and waste water costs of
4.0 Euro/m³ the additional
costs of purchasing a Körting
ICE Condensation Vacuum
System compared to a con-
ventional steam jet vacuum
system can be expected to be
recovered in about 3 years.
After that time the system is
saving money.
N. B. payback time are based
on the ex-works price exclud-
ing installation and commis-
sioning.
Example (600 tons/day) Index
Steam jet vacuum system with waste water → 4.8
Körting ICE Condensation Vacuum System → 1.6
Investment cost difference → 10.0
Payback time 10.0 / (4.8 - 1.6) = 10 / 3.2 3.1 years
sunderdiek.de
Körting Hannover AG
Badenstedter Straße 56
30453 Hannover
Germany
Tel.: +49 511 2129-253
Fax: +49 511 2129-223
st@koerting.de
www.koerting.de
222-ICE-EN-150518

Weitere ähnliche Inhalte

Was ist angesagt?

15679104 basic-civil-and-mechanical-engineering-unit-v
15679104 basic-civil-and-mechanical-engineering-unit-v15679104 basic-civil-and-mechanical-engineering-unit-v
15679104 basic-civil-and-mechanical-engineering-unit-v
Mahendiran Subramaniyan
 
SOLAR POWER VAPOUR ABSORPTION REFRIGERATION SYSTEM
SOLAR POWER VAPOUR ABSORPTION REFRIGERATION SYSTEMSOLAR POWER VAPOUR ABSORPTION REFRIGERATION SYSTEM
SOLAR POWER VAPOUR ABSORPTION REFRIGERATION SYSTEM
aj12345ay
 

Was ist angesagt? (20)

Different types of chiller
Different types of chillerDifferent types of chiller
Different types of chiller
 
waste heat recovery
waste heat recovery waste heat recovery
waste heat recovery
 
Vapour Absorption Refrigeration System
Vapour Absorption Refrigeration SystemVapour Absorption Refrigeration System
Vapour Absorption Refrigeration System
 
REFRIGERATION CYCLE - BASICS OF HVAC
REFRIGERATION CYCLE - BASICS OF HVACREFRIGERATION CYCLE - BASICS OF HVAC
REFRIGERATION CYCLE - BASICS OF HVAC
 
Centrifugal Compressor
Centrifugal CompressorCentrifugal Compressor
Centrifugal Compressor
 
Hvac basics lunch & learn
Hvac basics lunch & learnHvac basics lunch & learn
Hvac basics lunch & learn
 
Basic compressed air
Basic compressed air Basic compressed air
Basic compressed air
 
Refrigerant
RefrigerantRefrigerant
Refrigerant
 
Types of air conditioning systems
Types of air conditioning systemsTypes of air conditioning systems
Types of air conditioning systems
 
GASOLINE DIRECT INJECTION SYSTEM
GASOLINE DIRECT INJECTION SYSTEMGASOLINE DIRECT INJECTION SYSTEM
GASOLINE DIRECT INJECTION SYSTEM
 
15679104 basic-civil-and-mechanical-engineering-unit-v
15679104 basic-civil-and-mechanical-engineering-unit-v15679104 basic-civil-and-mechanical-engineering-unit-v
15679104 basic-civil-and-mechanical-engineering-unit-v
 
Seminar presentation on Vapour Compression Refrigeration
Seminar presentation on Vapour Compression RefrigerationSeminar presentation on Vapour Compression Refrigeration
Seminar presentation on Vapour Compression Refrigeration
 
SOLAR POWER VAPOUR ABSORPTION REFRIGERATION SYSTEM
SOLAR POWER VAPOUR ABSORPTION REFRIGERATION SYSTEMSOLAR POWER VAPOUR ABSORPTION REFRIGERATION SYSTEM
SOLAR POWER VAPOUR ABSORPTION REFRIGERATION SYSTEM
 
Vapour Absorption Refrigeration System
Vapour Absorption Refrigeration SystemVapour Absorption Refrigeration System
Vapour Absorption Refrigeration System
 
Basics of Refrigerartion
Basics of RefrigerartionBasics of Refrigerartion
Basics of Refrigerartion
 
Evaporator by om
Evaporator by omEvaporator by om
Evaporator by om
 
CONDENSERS & COOLING TOWERS
CONDENSERS & COOLING TOWERSCONDENSERS & COOLING TOWERS
CONDENSERS & COOLING TOWERS
 
Hvac systems presentation_slides
Hvac systems presentation_slidesHvac systems presentation_slides
Hvac systems presentation_slides
 
Hvac - presentation (Air conditioning presentation)
Hvac - presentation (Air conditioning presentation) Hvac - presentation (Air conditioning presentation)
Hvac - presentation (Air conditioning presentation)
 
Thermal power plants
Thermal power plantsThermal power plants
Thermal power plants
 

Ähnlich wie Ice Condensation vacuum systems

K10880 deepaknagar vapour absorption technology
K10880 deepaknagar vapour absorption technologyK10880 deepaknagar vapour absorption technology
K10880 deepaknagar vapour absorption technology
gurjarajeet
 
K10880 deepaknagar vapour absorption technology deepak
K10880 deepaknagar vapour absorption technology deepakK10880 deepaknagar vapour absorption technology deepak
K10880 deepaknagar vapour absorption technology deepak
gurjarajeet
 
Chiller Plant-EN - Catalogue
Chiller Plant-EN - CatalogueChiller Plant-EN - Catalogue
Chiller Plant-EN - Catalogue
Tomas Eriksson
 
Recovery of Engine Waste Heat for Reutilization in Air Conditioning System in...
Recovery of Engine Waste Heat for Reutilization in Air Conditioning System in...Recovery of Engine Waste Heat for Reutilization in Air Conditioning System in...
Recovery of Engine Waste Heat for Reutilization in Air Conditioning System in...
Joel John
 
Cooling system
Cooling systemCooling system
Cooling system
Ajay Yadav
 
Generation of Air Conditioning by using Exhaust Gases and Cooling Water of an...
Generation of Air Conditioning by using Exhaust Gases and Cooling Water of an...Generation of Air Conditioning by using Exhaust Gases and Cooling Water of an...
Generation of Air Conditioning by using Exhaust Gases and Cooling Water of an...
ijtsrd
 
Cooling applications of solar system ppt
Cooling applications of solar system pptCooling applications of solar system ppt
Cooling applications of solar system ppt
vikramdangi
 
Improving Efficiency of Cooling Coil Chiller Units
Improving Efficiency of Cooling Coil Chiller UnitsImproving Efficiency of Cooling Coil Chiller Units
Improving Efficiency of Cooling Coil Chiller Units
Dr. Amarjeet Singh
 

Ähnlich wie Ice Condensation vacuum systems (20)

K10880 deepaknagar vapour absorption technology
K10880 deepaknagar vapour absorption technologyK10880 deepaknagar vapour absorption technology
K10880 deepaknagar vapour absorption technology
 
K10880 deepaknagar vapour absorption technology deepak
K10880 deepaknagar vapour absorption technology deepakK10880 deepaknagar vapour absorption technology deepak
K10880 deepaknagar vapour absorption technology deepak
 
Technical description bvg 2014 (upgrading) (en) light
Technical description bvg 2014 (upgrading) (en) lightTechnical description bvg 2014 (upgrading) (en) light
Technical description bvg 2014 (upgrading) (en) light
 
IRJET- Adsorption Air Conditioning for Automobiles using Waste Heat Recov...
IRJET-  	  Adsorption Air Conditioning for Automobiles using Waste Heat Recov...IRJET-  	  Adsorption Air Conditioning for Automobiles using Waste Heat Recov...
IRJET- Adsorption Air Conditioning for Automobiles using Waste Heat Recov...
 
Chiller Plant-EN - Catalogue
Chiller Plant-EN - CatalogueChiller Plant-EN - Catalogue
Chiller Plant-EN - Catalogue
 
Chiller Plant-EN - Catalogue
Chiller Plant-EN - CatalogueChiller Plant-EN - Catalogue
Chiller Plant-EN - Catalogue
 
Agc wp-hydroscavprincop
Agc wp-hydroscavprincopAgc wp-hydroscavprincop
Agc wp-hydroscavprincop
 
Recovery of Engine Waste Heat for Reutilization in Air Conditioning System in...
Recovery of Engine Waste Heat for Reutilization in Air Conditioning System in...Recovery of Engine Waste Heat for Reutilization in Air Conditioning System in...
Recovery of Engine Waste Heat for Reutilization in Air Conditioning System in...
 
Cooling
CoolingCooling
Cooling
 
cooling and lubrication system
cooling and lubrication systemcooling and lubrication system
cooling and lubrication system
 
Cooling system
Cooling systemCooling system
Cooling system
 
IC Engines lubrication & cooling methods
IC Engines lubrication & cooling methodsIC Engines lubrication & cooling methods
IC Engines lubrication & cooling methods
 
Automotive cooling system
Automotive cooling systemAutomotive cooling system
Automotive cooling system
 
Generation of Air Conditioning by using Exhaust Gases and Cooling Water of an...
Generation of Air Conditioning by using Exhaust Gases and Cooling Water of an...Generation of Air Conditioning by using Exhaust Gases and Cooling Water of an...
Generation of Air Conditioning by using Exhaust Gases and Cooling Water of an...
 
Modification of Generator In Electrolux Refrigerator
Modification of Generator In Electrolux RefrigeratorModification of Generator In Electrolux Refrigerator
Modification of Generator In Electrolux Refrigerator
 
PERFORMANCE ANALYSIS OF VAPOR COMPRESSION REFRIGERATION SYSTEM USING DIFFEREN...
PERFORMANCE ANALYSIS OF VAPOR COMPRESSION REFRIGERATION SYSTEM USING DIFFEREN...PERFORMANCE ANALYSIS OF VAPOR COMPRESSION REFRIGERATION SYSTEM USING DIFFEREN...
PERFORMANCE ANALYSIS OF VAPOR COMPRESSION REFRIGERATION SYSTEM USING DIFFEREN...
 
Cooling applications of solar system ppt
Cooling applications of solar system pptCooling applications of solar system ppt
Cooling applications of solar system ppt
 
Boiler Efficiency & Improvements.pptx
Boiler Efficiency & Improvements.pptxBoiler Efficiency & Improvements.pptx
Boiler Efficiency & Improvements.pptx
 
Effect of compressor heating and cooling
Effect of compressor heating and coolingEffect of compressor heating and cooling
Effect of compressor heating and cooling
 
Improving Efficiency of Cooling Coil Chiller Units
Improving Efficiency of Cooling Coil Chiller UnitsImproving Efficiency of Cooling Coil Chiller Units
Improving Efficiency of Cooling Coil Chiller Units
 

Mehr von Tomas Eriksson

Venturi Scrubber - Dedusting
Venturi Scrubber - DedustingVenturi Scrubber - Dedusting
Venturi Scrubber - Dedusting
Tomas Eriksson
 
Multistage-steam-jet-vacuum-ejectors
Multistage-steam-jet-vacuum-ejectorsMultistage-steam-jet-vacuum-ejectors
Multistage-steam-jet-vacuum-ejectors
Tomas Eriksson
 
Alkaline Cloosed Loop vacuum systems
Alkaline Cloosed Loop vacuum systemsAlkaline Cloosed Loop vacuum systems
Alkaline Cloosed Loop vacuum systems
Tomas Eriksson
 
Textile - Caustic Recovery-email
Textile - Caustic Recovery-emailTextile - Caustic Recovery-email
Textile - Caustic Recovery-email
Tomas Eriksson
 
Water and Waste Water Treatment - EN - 140716 - webreduced
Water and Waste Water Treatment - EN - 140716 - webreducedWater and Waste Water Treatment - EN - 140716 - webreduced
Water and Waste Water Treatment - EN - 140716 - webreduced
Tomas Eriksson
 
Tank Mixing Systems - EN - webreduced
Tank Mixing Systems - EN - webreducedTank Mixing Systems - EN - webreduced
Tank Mixing Systems - EN - webreduced
Tomas Eriksson
 
Koerting - Institutional
Koerting - InstitutionalKoerting - Institutional
Koerting - Institutional
Tomas Eriksson
 

Mehr von Tomas Eriksson (8)

Venturi Scrubber - Dedusting
Venturi Scrubber - DedustingVenturi Scrubber - Dedusting
Venturi Scrubber - Dedusting
 
Multistage-steam-jet-vacuum-ejectors
Multistage-steam-jet-vacuum-ejectorsMultistage-steam-jet-vacuum-ejectors
Multistage-steam-jet-vacuum-ejectors
 
Alkaline Cloosed Loop vacuum systems
Alkaline Cloosed Loop vacuum systemsAlkaline Cloosed Loop vacuum systems
Alkaline Cloosed Loop vacuum systems
 
Shipbuilding-web
Shipbuilding-webShipbuilding-web
Shipbuilding-web
 
Textile - Caustic Recovery-email
Textile - Caustic Recovery-emailTextile - Caustic Recovery-email
Textile - Caustic Recovery-email
 
Water and Waste Water Treatment - EN - 140716 - webreduced
Water and Waste Water Treatment - EN - 140716 - webreducedWater and Waste Water Treatment - EN - 140716 - webreduced
Water and Waste Water Treatment - EN - 140716 - webreduced
 
Tank Mixing Systems - EN - webreduced
Tank Mixing Systems - EN - webreducedTank Mixing Systems - EN - webreduced
Tank Mixing Systems - EN - webreduced
 
Koerting - Institutional
Koerting - InstitutionalKoerting - Institutional
Koerting - Institutional
 

Ice Condensation vacuum systems

  • 1. Körting ICE Condensation Vacuum System for edible oil applications
  • 2. Like all vegetable oil processing vacuum sys- tems, Körting ICE Condensation Vacuum Systems are able to operate an oil deodoris- ing plant in the range between 1 - 4 mbar by extracting sparging steam and air. In contrast to conventional vacuum systems, Körting ICE Condensation Vacuum Systems allow the process vapour to be condensed close to the operation pressure of the deodor- iser (rather than having to compress it first with steam jet boosters then condense it to liquid). At a.m. pressures, condensation occurs be- tween -20 °C and -5 °C, so in order to operate such condenser, a refrigerant to be circulated through its tubes at temperatures down to -30 °C is required. This results in the steam condensing as a solid ice coating outside of the condenser tubes. The ice layer has to be regularly removed by melting. In order to operate in a continuous cycle, Körting ICE Condensation Vacuum Sys- tems utilise two parallel ice condensers which are operated alternately. One ice condenser is in operation (being charged) whereas the other one is heated with hot water vapour to melt the ice layer. At preset intervals, the clean, ice free condenser is pre-cooled before it is then switched back into the circuit whereas the other is disconnected to begin its melting cycle. The sequence is designed in such a way that the vacuum level is not increased when switching over from one condenser to the other. ICE Condensation Vacuum System In the today's market, Körting ICE Condensation Vacuum System make sense! Ice condensation block completely assembled in the workshop Assembly of an ice condensation block at site
  • 3. Significant energy savings with virtually zero environmental pollution Körting ICE Condensation Systems have two principle advantages: • The refrigerated coolant and the polluted sparging steam are strictly separated, which pro- tects the environment considerably. • The coolant compressor operates at a higher efficiency compared to steam jet boosters of a conventional vacuum system. Therefore, energy and operarting costs are saved significantly. The original concept was proposed by G. B. Martinenghi (1964) but at that time the high capital cost of the system compared to conventional vacuum systems proved uneconomical. Today with increasing energy costs and strict environmental emission controls (waste water, air pollution), the ice condensation system is the most economic vacuum system for this application. Körting ICE Condensation Vacuum Systems are based on many years of experience with a lot of installations world wide since 1988. It is computer controlled and designed to be both: Simple and reliable in operation. Ice condensation block completely installed at site Front view of an ice condensation unit
  • 4. cooling water air evacuation group liquid ring vacuum pump heating steam closed open ice condenser A PI condensate (clean) TIC melting vessel MIN MAX ammonia separator PIC from deodoriser spraying pump ammonia compressor bleed expansion valve evaporative condenser (ammonia condenser) Fan fresh water ice condenser B waste water (highly poluted) condensate pump TI loading melting precooling loading melting precooling waste water (slightly poluted) gas outlet cooling water cooling water ejector (2nd stage) ejector (1st stage) condenser air evacuation PI PI PI PI Flow chart of an Körting ICE Condensation Vacuum System Condensing The sparging steam from the deodoriser, pol- luted by fatty acids and other impurities and fatty substances, is alternately supplied to the ice condenser A or B. High performance butterfly valves are used to isolate the ice condenser from the process during melt- ing. The condenser being charged is kept at low temperature by circulating the refrigerant through the tubes. The refrigerant is conveyed in a liquid state from the refrigerant separator and evaporated within the tubes of the con- denser by absorbing of the condensation heat of the sparging steam.Typically, this process is regulated to produce surface temperatures of around -15 °C to -25 °C on the tubes. This is below the condensation temperature of the sparging steam drawn from the deodoriser so the steam together with most of its impuri- ties is condensed on the outside of the tubes as a coating of ice mixed with fatty crystals. Melting After a loading time which, according to the design, may be between one and two hours the process flow is switched to the other ice condenser. The charged ice condenser (now with its cooling elements thoroughly coated with ice) is entirely separated from the deodor- iser and heated to approx. 60 °C to 80 °C with vapour originating from the polluted conden- sate in the heated melting vessel. The molten ice which is a mixture of water, oil and fatty substances runs off from the tubes and back into the melting vessel. How do Körting ICE Condensation Vacuum System work? The essential elements of the plant are illustrated in the figure above. In this example, ice condenser B is in use (being charged), ice condenser A is in its melting cycle.
  • 5. condensate pump rupture disc ice condensers compressor refrigerant gas inlet cooling water condensate to the ammonia condenser from the ammonia separator liquid ring vacuum pump atmosphere gas outlet over flow heating steam melting vessel condensate air evacuation group cooling water gas outlet evaporative condenser cleaning connection cooling water fresh water motive steam to the ammonia compressor motive steam air evacuation safety valve ammonia separator rupture disc from the evaporative condenser to the refrigerant separator bleed from the refrigerant compressor deodoriser waste water scrubber Condensate discharge The surplus liquid from the melting vessel which contains most of the impurities of the origi- nal sparging steam is discharged from the melting vessel by a con- densate pump. Steam jet ejectors In order to evacuate all non- condensables from the ice con- densers, a small 2-stage steam jet ejector vacuum group com- bined with a liquid ring vacuum pump is used. Cooling water for the interconnected small surface condenser as well as ejectors and the liquid ring vacuum pump will be kept clean. Only the small amount of condensate leaving the small surface condenser is slightly polluted and will leave the system at the separator of the liquid ring vauum pump. At this point the ex- hausted gas of the process is also discharged to the atmosphere. Coolant refrigeration To minimise the maintenance costs and for high operating reli- ability, the Körting ice condensation vacuum system operates with twin-shaft screw compressors (refrigerant compressor). Typical installation of an ICE Condensation Vacuum System at an oil deodorising column 2-stage steam jet vacuum ejectors with shell and tube condenser Screw compressor for refrigeration
  • 6. Körting ICE Condensation Vacuum Systems produce nearly no pollutants. This is principally based on the fact that the cooling water is kept strictly separated from the condensate of the polluted sparge steam. As condensation takes place at low tempera- ture and at the pressure level in the deodor- iser, the melted condensate flowing from ice condenser A and B is undiluted and highly concentrated (almost 100 % of the high-boiling oil components, i.e. fatty acids, which are exhausted during deodorisation can be found in condensate). Only some low-boiling substances such as aldehydes and ketones are exhausted from the ice condensers by the steam jet ejectors together with the non-condensable gas. The motive flow of the ejectors as well as the condensable parts of the suction flow are con- densed in a downstream surface condenser. There is no contact with the cooling water. For the atmospheric stage of the air evacuation unit, a liquid ring vacuum pump is used. To re- move the condensation and compression heat, the service water (polluted with low-boiling oil substances) is passed through a heat exchang- er in a closed loop so that no oil substances may enter the cooling water. Non condensable gases from the process and the leakage air, which enters the deodoriser, is polluted with low-boiling oil substances. This gas mixture is the only exhaust flow discharged from the unit by means of the liquid ring vacu- um pump via the liquid separator. This exhaust gas can be treated by combustion in a steam boiler or in a biological filter plant. Mechanical vacuum pumps (roots blowers) can be used instead of the steam jet vacuum ejectors. However, this is generally not recom- mended because mechanical pumps are much more susceptible to failures. Melting vessel of a Körting ICE Condensation Vacuum System Molten condensate in the melting vessel Why do Körting ICE Condensation Vacuum Systems produce virtually zero environmental pollution?
  • 7. Körting ICE Condensation Vacuum Systems save money! The figure below illustrates the typical payback time for the investment of a Körting ICE Conden- sation Vacuum System compared to a steam jet vacuum ejector system with direct contact condensation. The graph is calculated for a condensation pressure of 1.5 mbar which cor- responds to a deodoriser pressure of around 2.5 mbar and a cooling water inlet temperature of max. 33 °C. The graph shows that the payback time depends on the oil production capacity, based on fixed prices for steam, electricity, cooling water and waste water. The bigger the oil production capacity (the higher the condensation rate of the ice condensation vacuum system), the shorter the payback time. If the steam price (for motive steam of the comparable steam jet vacuum ejector system) is high, the payback time of the Körting ICE Condensation Vacuum System will be consider- ably reduced. The comparison between a Körting ICE Condensation Vacuum System and a conventional steam jet vacuum ejector system as well as the operating costs depend on two principal factors: • Based on standard specific costs for steam and electricity the total operating costs for a Körting ICE Con- densation Vacuum System are much lower compared to a conventional steam jet vacuum system. • Investment costs are higher – Körting ICE Condensation Vacuum Systems require higher initial investment compared to other vacuum producing equipments used in the processing of edible oils and fats but they offer a short payback time. → Operating costs of ice condensation vacuum system Operating costs for steam jet vacuum system Investment cost difference Index oil production capacity (TPD) 100 200 300 400 500 600 700 800 0 1 2 3 4 5 6 7 8 9 10 11 12 Example For an oil production capacity of 600 tons/day and a motive steam price of 25 Euro/ton, electric power of 0.1 Euro/kWh and waste water costs of 4.0 Euro/m³ the additional costs of purchasing a Körting ICE Condensation Vacuum System compared to a con- ventional steam jet vacuum system can be expected to be recovered in about 3 years. After that time the system is saving money. N. B. payback time are based on the ex-works price exclud- ing installation and commis- sioning. Example (600 tons/day) Index Steam jet vacuum system with waste water → 4.8 Körting ICE Condensation Vacuum System → 1.6 Investment cost difference → 10.0 Payback time 10.0 / (4.8 - 1.6) = 10 / 3.2 3.1 years
  • 8. sunderdiek.de Körting Hannover AG Badenstedter Straße 56 30453 Hannover Germany Tel.: +49 511 2129-253 Fax: +49 511 2129-223 st@koerting.de www.koerting.de 222-ICE-EN-150518