SlideShare ist ein Scribd-Unternehmen logo
1 von 20
A histomorghometric study of screw-
shaped and removal torque titanium
implants with three different surface
           topographies


             ALI ALENEZI
The authors
• A. Wennerberg, T. Albrektsson, B. Andersson, J. J. Krol.



• Published by: Clinical Oral Implants Research

   Volume 6, Issue 1, pages 24–30, March 1995
The aim of the study:

To investigate bone response in relation to well defined
surface over short time of follow-up.



                                      Blasted with TiO2
     Turned surface
                                      25µm particles


                     Blasted with Al2O3
                     75µm particles
Surface quality
    One of the six factors that influence the biological response to
    implant ( alberktsson et al. 1981)

                                                            Surface
                                                            quality
The remaining 5 factors:
• Implant biocompatibility                Loading                          Implant
                                                                         biocompatib
                                         conditions                          ility

•   Implant design
• State of host bed                                   Osseointegration

• Surgical Technique                      Surgical                        Implant
                                         Technique                         design
• Loading conditions
                                                           State of
                                                           host bed
The concept of surface quality


It includes:
  All Surface properties
  (mechanical, physical, chemical, topographical).

  The influence of surface quality on implant integration
  investigated in many studies at that time (1980s &1990s).
Implant surface roughness
- better bone-forming capability around rough implant in
compared with smooth ones ( carlsson et al. 1988).



The suggested explanations:

1- more advantageous stress transfer.

2- better mechanical interlocking (kasemo 1983).
Materials and methods
 The implant have been characterized in to 3 different
 topographies.

 10 new Zealand rabbits.

 60 screw shaped commercially pure titanium.

 Implants length; 6mm, diameter: 3.75, pitch height: 0.6mm



Surface topography                                   Number of implants
Turned surface                                       30
Blasted with TiO2 particles, with a diameter 25µm    20
Blasted with Al2O3 particles, with a diameter 75µm   10
The blasting process

Basic due
(renfert, Germany)

After blasting process, all
the implants cleaned
ultrasonically in
trichloroethylene and 70%
ethanol
Surface topography
             examination
Optical profilometer, topscan 3D .
  Non contact mode

  Visual images

  Numerical values for surface roughness.

  240x245 μm measurement area
Surface roughness parameters
      In this paper, 7 different height parameters used
      to describe the roughness.

Ra          The arithmetic mean of departures of the roughness profile
            from the mean lines
Rq          the root mean square parameter corresponding to Ra


Rt          the maximum peak to valley height in the evaluation area

Rsk         The measures of the symmetry of the profile

Rku         The measures of the sharpness of the surface profile.


∆q          the root mean square slope of the surface

πq          the root mean square measure of spacings between local
            peaks and valleys
Surgical technique
1 rabbit = 6 implants



                           RIGHT   LEFT


               FEMUR       Al2O3   turned


             PROXIMAL      TiO2    turned
               TIBIA

            DISTAL TIBIA   TiO2    turned
Torque measurement and
histomorphometrical analysis
For torque measurement:
  40 implants (20 from femur and 20 from distal tibia).

  Slowly increasing torque was gradually applied until loosening of
  implant.



For histomorphometrical analysis:
  20 implants ( proximal tibia)

  Cutting & grinding by (Exakt equipments)

  10 μm section thickness.

   To measure:     1- % bone to metal contact.

                   2- The amount of bone area.
Results
Turned screws :
  exhibited the smoothest surface

  Surface with clear direction of irregularities.

Screws blasted with TiO2:
  More homogenous surface.

  Increased roughness.

Screws blasted with Al2O3:
  the roughest surface.

  homogenous surface.
Results
The blasting procedure was responsible for
decreasing the (outer &core) diameter of implants
Results
  Removal torque values necessary to remove the
  screws after 12 weeks:

In femur:

Screw blasted with Al2O3   > turned.
In tibia:

Screw blasted with TiO2    >   turned.
Results
Histomorphometric analysis:
- Bone metal contact % :
Higher for TiO2 25-µm

implants compared

with turned implants.
Results
  Histomorphometric analysis:


- Bone surface area:

Greater bone area for turned
implants when compared
 with TiO2-blasted implants
discussion
  The implants that been treated with blasting
  procedures show higher removal torque values and
  higher percentage of contact bone to the metal
  surface.



On the other hand,,,

  Turned implants had more bone surface area after 12
  weeks.
In this study:
  The same surgical instrument were used for all implants,
  which not have the same exact diameter (the blasting
  process cause a minor reduction).
  But, the blasted implants showed better interfacial healing
  response.
  Furthermore, we have different surface irregularities
  between blasted and turned implants.
  Its short term results. Not to be generalized especially
  For clinical reality.
Thank you

Weitere ähnliche Inhalte

Was ist angesagt?

Was ist angesagt? (20)

Journal club presentaion on zirconia fixed partial dentured on endodonticaloy...
Journal club presentaion on zirconia fixed partial dentured on endodonticaloy...Journal club presentaion on zirconia fixed partial dentured on endodonticaloy...
Journal club presentaion on zirconia fixed partial dentured on endodonticaloy...
 
Adhesion to titanium implants in dentistry
Adhesion to titanium implants in dentistryAdhesion to titanium implants in dentistry
Adhesion to titanium implants in dentistry
 
2.recent advances in implant surface science
2.recent advances in implant surface science2.recent advances in implant surface science
2.recent advances in implant surface science
 
Obturation Techniques in Primary Teeth
Obturation Techniques in Primary TeethObturation Techniques in Primary Teeth
Obturation Techniques in Primary Teeth
 
Surgical procedures in fixed partial dentures / dentistry dental implants
Surgical procedures in fixed partial dentures / dentistry dental implantsSurgical procedures in fixed partial dentures / dentistry dental implants
Surgical procedures in fixed partial dentures / dentistry dental implants
 
Implant materials
Implant materialsImplant materials
Implant materials
 
Implant seminar
Implant seminarImplant seminar
Implant seminar
 
root surface treatment in periodontics
root surface treatment in periodonticsroot surface treatment in periodontics
root surface treatment in periodontics
 
Indirect Bonding in Orthodontics
Indirect Bonding in OrthodonticsIndirect Bonding in Orthodontics
Indirect Bonding in Orthodontics
 
Evaluation of Marginal integrity and Depth of Cure for three ‘bulk fill’ comp...
Evaluation of Marginal integrity and Depth of Cure for three ‘bulk fill’ comp...Evaluation of Marginal integrity and Depth of Cure for three ‘bulk fill’ comp...
Evaluation of Marginal integrity and Depth of Cure for three ‘bulk fill’ comp...
 
Pre implant anatomy, biology, function and risk factors of an implant placements
Pre implant anatomy, biology, function and risk factors of an implant placementsPre implant anatomy, biology, function and risk factors of an implant placements
Pre implant anatomy, biology, function and risk factors of an implant placements
 
Dental Implants- part I and II: Biological and surgical aspects
Dental Implants- part I and II: Biological and surgical aspectsDental Implants- part I and II: Biological and surgical aspects
Dental Implants- part I and II: Biological and surgical aspects
 
"GUIDED TISSUE REGENERATION"
"GUIDED TISSUE REGENERATION""GUIDED TISSUE REGENERATION"
"GUIDED TISSUE REGENERATION"
 
periodontal regenerative procedures
periodontal regenerative proceduresperiodontal regenerative procedures
periodontal regenerative procedures
 
journal club presentation- prosthodontics-Deformation and retentive force fol...
journal club presentation- prosthodontics-Deformation and retentive force fol...journal club presentation- prosthodontics-Deformation and retentive force fol...
journal club presentation- prosthodontics-Deformation and retentive force fol...
 
Preparation of periodontally weakened teeth
 Preparation of periodontally weakened teeth  Preparation of periodontally weakened teeth
Preparation of periodontally weakened teeth
 
Materials used in pediatric endodontics
Materials used in pediatric endodonticsMaterials used in pediatric endodontics
Materials used in pediatric endodontics
 
Emdogain by dr. maryam salman
Emdogain by dr. maryam salmanEmdogain by dr. maryam salman
Emdogain by dr. maryam salman
 
Perioplastic surgeries- width of attached gingiva
Perioplastic surgeries- width of attached gingivaPerioplastic surgeries- width of attached gingiva
Perioplastic surgeries- width of attached gingiva
 
Regenerative osseous surgery
Regenerative osseous surgeryRegenerative osseous surgery
Regenerative osseous surgery
 

Ähnlich wie A histomorghometric study of screw-shaped and removal torque titanium implants with three different surface topographies

Arthroscopic cuff repair
Arthroscopic cuff repairArthroscopic cuff repair
Arthroscopic cuff repair
orthoprince
 
Basics Of Implantology - Dr Harshavardhan Patwal
Basics Of Implantology - Dr Harshavardhan PatwalBasics Of Implantology - Dr Harshavardhan Patwal
Basics Of Implantology - Dr Harshavardhan Patwal
Dr Harshavardhan Patwal
 
Η χειρουργική του ισχίου σήμερα
Η χειρουργική του ισχίου σήμεραΗ χειρουργική του ισχίου σήμερα
Η χειρουργική του ισχίου σήμερα
bitounis
 
Piezoelectric surgery in periodontics & oral implantology
Piezoelectric surgery in periodontics & oral implantologyPiezoelectric surgery in periodontics & oral implantology
Piezoelectric surgery in periodontics & oral implantology
Dr. Bibina George
 

Ähnlich wie A histomorghometric study of screw-shaped and removal torque titanium implants with three different surface topographies (20)

Impact of dental implant surface modifications on Osseo-integration
Impact of dental implant surface modifications on Osseo-integrationImpact of dental implant surface modifications on Osseo-integration
Impact of dental implant surface modifications on Osseo-integration
 
Recent Advances in Implant Surface Science
Recent Advances in Implant Surface ScienceRecent Advances in Implant Surface Science
Recent Advances in Implant Surface Science
 
An brief overview on implants and its systems with modifications
An brief overview on implants and its systems with modificationsAn brief overview on implants and its systems with modifications
An brief overview on implants and its systems with modifications
 
Porcelain Layering On Zirconia Coping
Porcelain Layering On Zirconia CopingPorcelain Layering On Zirconia Coping
Porcelain Layering On Zirconia Coping
 
Implant
ImplantImplant
Implant
 
Arthroscopic cuff repair
Arthroscopic cuff repairArthroscopic cuff repair
Arthroscopic cuff repair
 
surface treatment.pptx
surface treatment.pptxsurface treatment.pptx
surface treatment.pptx
 
1 s2.0-s0099239911004882-main
1 s2.0-s0099239911004882-main1 s2.0-s0099239911004882-main
1 s2.0-s0099239911004882-main
 
Implant surface vs osseointegration
Implant surface vs osseointegrationImplant surface vs osseointegration
Implant surface vs osseointegration
 
Ring compression test
Ring compression test Ring compression test
Ring compression test
 
Technique for Placement of Oxidized Titanium Implants by Oded Bahat
Technique for Placement of Oxidized Titanium Implants by Oded BahatTechnique for Placement of Oxidized Titanium Implants by Oded Bahat
Technique for Placement of Oxidized Titanium Implants by Oded Bahat
 
journal club presentation on prosthodontics
journal club presentation on prosthodonticsjournal club presentation on prosthodontics
journal club presentation on prosthodontics
 
Osseointegration notes
Osseointegration notesOsseointegration notes
Osseointegration notes
 
silver nanoparticles relation on properties of silicone elastomer
silver nanoparticles relation on properties of silicone elastomersilver nanoparticles relation on properties of silicone elastomer
silver nanoparticles relation on properties of silicone elastomer
 
10.1177@0954411919878306
10.1177@095441191987830610.1177@0954411919878306
10.1177@0954411919878306
 
Basics Of Implantology - Dr Harshavardhan Patwal
Basics Of Implantology - Dr Harshavardhan PatwalBasics Of Implantology - Dr Harshavardhan Patwal
Basics Of Implantology - Dr Harshavardhan Patwal
 
Η χειρουργική του ισχίου σήμερα
Η χειρουργική του ισχίου σήμεραΗ χειρουργική του ισχίου σήμερα
Η χειρουργική του ισχίου σήμερα
 
51024737 pt-weld
51024737 pt-weld51024737 pt-weld
51024737 pt-weld
 
Piezoelectric surgery in periodontics & oral implantology
Piezoelectric surgery in periodontics & oral implantologyPiezoelectric surgery in periodontics & oral implantology
Piezoelectric surgery in periodontics & oral implantology
 
Microimplant characterisation
Microimplant characterisationMicroimplant characterisation
Microimplant characterisation
 

A histomorghometric study of screw-shaped and removal torque titanium implants with three different surface topographies

  • 1. A histomorghometric study of screw- shaped and removal torque titanium implants with three different surface topographies ALI ALENEZI
  • 2. The authors • A. Wennerberg, T. Albrektsson, B. Andersson, J. J. Krol. • Published by: Clinical Oral Implants Research Volume 6, Issue 1, pages 24–30, March 1995
  • 3. The aim of the study: To investigate bone response in relation to well defined surface over short time of follow-up. Blasted with TiO2 Turned surface 25µm particles Blasted with Al2O3 75µm particles
  • 4. Surface quality One of the six factors that influence the biological response to implant ( alberktsson et al. 1981) Surface quality The remaining 5 factors: • Implant biocompatibility Loading Implant biocompatib conditions ility • Implant design • State of host bed Osseointegration • Surgical Technique Surgical Implant Technique design • Loading conditions State of host bed
  • 5. The concept of surface quality It includes: All Surface properties (mechanical, physical, chemical, topographical). The influence of surface quality on implant integration investigated in many studies at that time (1980s &1990s).
  • 6. Implant surface roughness - better bone-forming capability around rough implant in compared with smooth ones ( carlsson et al. 1988). The suggested explanations: 1- more advantageous stress transfer. 2- better mechanical interlocking (kasemo 1983).
  • 7. Materials and methods The implant have been characterized in to 3 different topographies. 10 new Zealand rabbits. 60 screw shaped commercially pure titanium. Implants length; 6mm, diameter: 3.75, pitch height: 0.6mm Surface topography Number of implants Turned surface 30 Blasted with TiO2 particles, with a diameter 25µm 20 Blasted with Al2O3 particles, with a diameter 75µm 10
  • 8. The blasting process Basic due (renfert, Germany) After blasting process, all the implants cleaned ultrasonically in trichloroethylene and 70% ethanol
  • 9. Surface topography examination Optical profilometer, topscan 3D . Non contact mode Visual images Numerical values for surface roughness. 240x245 μm measurement area
  • 10. Surface roughness parameters In this paper, 7 different height parameters used to describe the roughness. Ra The arithmetic mean of departures of the roughness profile from the mean lines Rq the root mean square parameter corresponding to Ra Rt the maximum peak to valley height in the evaluation area Rsk The measures of the symmetry of the profile Rku The measures of the sharpness of the surface profile. ∆q the root mean square slope of the surface πq the root mean square measure of spacings between local peaks and valleys
  • 11. Surgical technique 1 rabbit = 6 implants RIGHT LEFT FEMUR Al2O3 turned PROXIMAL TiO2 turned TIBIA DISTAL TIBIA TiO2 turned
  • 12. Torque measurement and histomorphometrical analysis For torque measurement: 40 implants (20 from femur and 20 from distal tibia). Slowly increasing torque was gradually applied until loosening of implant. For histomorphometrical analysis: 20 implants ( proximal tibia) Cutting & grinding by (Exakt equipments) 10 μm section thickness. To measure: 1- % bone to metal contact. 2- The amount of bone area.
  • 13. Results Turned screws : exhibited the smoothest surface Surface with clear direction of irregularities. Screws blasted with TiO2: More homogenous surface. Increased roughness. Screws blasted with Al2O3: the roughest surface. homogenous surface.
  • 14. Results The blasting procedure was responsible for decreasing the (outer &core) diameter of implants
  • 15. Results Removal torque values necessary to remove the screws after 12 weeks: In femur: Screw blasted with Al2O3 > turned. In tibia: Screw blasted with TiO2 > turned.
  • 16. Results Histomorphometric analysis: - Bone metal contact % : Higher for TiO2 25-µm implants compared with turned implants.
  • 17. Results Histomorphometric analysis: - Bone surface area: Greater bone area for turned implants when compared with TiO2-blasted implants
  • 18. discussion The implants that been treated with blasting procedures show higher removal torque values and higher percentage of contact bone to the metal surface. On the other hand,,, Turned implants had more bone surface area after 12 weeks.
  • 19. In this study: The same surgical instrument were used for all implants, which not have the same exact diameter (the blasting process cause a minor reduction). But, the blasted implants showed better interfacial healing response. Furthermore, we have different surface irregularities between blasted and turned implants. Its short term results. Not to be generalized especially For clinical reality.

Hinweis der Redaktion

  1. ----- Meeting Notes (10/7/12 23:30) -----well known researchers in implant surface studies
  2. ----- Meeting Notes (10/7/12 23:30) -----this study was investigatiing by doing histomorphometric analysis of 3 defined surfaces.all the screws were----- Meeting Notes (10/8/12 08:47) -----short term follow up
  3. ----- Meeting Notes (10/7/12 23:40) -----osseoinegration: direct implant bone contact even in hitological level.not only implant stability and enchorag by bone.
  4. ----- Meeting Notes (10/7/12 23:40) -----some studies specify the degree of roughness to be a moderate roughness
  5. ----- Meeting Notes (10/7/12 23:40) -----the rabbits: same type,size, age with most of studies.also screw diameters. same other studies.
  6. ----- Meeting Notes (10/7/12 23:40) -----one of most common techniques:modification.----- Meeting Notes (10/7/12 23:44) -----TiO2), which stimulates osteointegration and prevents migration of metal ions and microsubstances into the body.----- Meeting Notes (10/7/12 23:46) -----Al2O3 will show also the same good biocompatibility
  7. ----- Meeting Notes (10/7/12 23:48) -----profilometer :measure a surface's profile, in order to quantify its roughness.
  8. ----- Meeting Notes (10/7/12 23:54) -----these 7 prameters are for numerical discription.the first 5 are for hight description.the last 2 for hight and space----- Meeting Notes (10/8/12 00:04) -----give numerical values and idea about the degree of surface roughness.
  9. ----- Meeting Notes (10/8/12 00:07) -----same location used.the average thickness of cortex bone used in rabbits is about 1-1.25 mm.with low speed rotary instruments, saline irrigation.
  10. ----- Meeting Notes (10/8/12 00:11) -----same as mentioned in other studies
  11. ----- Meeting Notes (10/8/12 00:11) -----they didnt expect that. its the oppsite direction of ther results like removal torque and BIC