A CASE STUDY ON CERAMIC INDUSTRY OF BANGLADESH.pptx
Shah faisal shah cv
1. Permanent Address: House # 10-B PAEC Chashlam Colony Chashma Barrage Mianwali,, Pakistan.
Cell: +92-3008871670 E-mail: faisal.engineer0@gmail.com
DOB: 22/07/1988 Skype ID: faisal.engineer0
NIC: 38303-6981353-1 PEC #: ELECT/43635
Passport#: DJ5153531
CAREER OBJECTIVE
I am now looking to build on my extensive range of technical skills within a suitably challenging role. I am
keen to achieve further professional development.
SUMMARY OF QUALIFICATIONS
Skilled and dedicated proficient offering an impressive 3-year leadership background in multinational and
National level companies with an exceptional understanding of management strategies and technical
environments. Provide comprehensive direction and solutions. Fluent in Urdu and English.
Areas of Expertise
220/132/11kV Grid Station Protection & Instrumentation
Electrical Engineer Protection & Maintenance
84 MW Power House, July 2014---Present
Madina Group of Industries Faisalabad, (MGI)
Madina Group of Industries has 184 MW Power House
Protection & Instrumentation of 33/11kV Grid Station.
Perform Maintenance Management like Preventive, Corrective, Predictive and Daily maintenance of
Transformer, circuit breaker, isolator, Current transformer, and Potential transformer.
Analyze and prepare the fault reports.
Efforts to minimize the breakdowns and minimize the breakdown time.
Work on protection of Electrical Power system like Line protection, Bus Bar protection, Transformer
protection, breakers protection, Battery Charger, Batteries Maintenance, Current transformer (CT),
Voltage transformer (VT), Isolators, Energy Meters, Relays, Switchgear room, and control circuits.
Annual Maintenance and testing of 33/11kV, 160MVA Auto Transformers. Test conducts are Transformer
Turns Ratio, Capacitance & Dissipation Factor (C&DF), Insulation Resistance Test, DES, Differential
Balancing, Open Circuit, Short Circuit
Annual Maintenance and testing of 33kV Circuit breakers. Test Conducts are: Contact Resistance Test,
Breaker Timing Test etc.
Testing, configuration and communication of Relays like Numerical relays/digital relays/static
relays/electromechanical relays (ABB, AREVA, SIEMENS, and GE).
Annual testing of all Protective Relays including Overcurrent (CDG, MCGG, ABB SPAJ 140C, Siemens
Siprotec 7SJ6005, GE Multiline MIFII), Differential Relays (DTH, D2e, 7UT612, RADSB), Distance Relay
(L3wys,LZ-96a,REL521), Restricted Earth Fault Relay, Breaker Failure, Under Frequency, Over fluxing etc
Testing of all mechanical Relays (Bucholz, Temperature gauges, Pressure Relieve Device (PRD))
Erection, Installation & commissioning of Transformers, breakers and all Grid Station related equipments.
Hands on Experience of Testing kits: Severker 780, Freja 300, Freja 306, ZFB, QZW, Megger, CT Analyzer,
Breaker Analyzer TM-1600, MOM600, Primary Injection ODEN At, CB-100 etc
Engr.Shah Faisal Shah
Protection & Maintenance of 220/132/11kV Grid Station
Utility Maintenance & Operation Management
New Utility Project Management
Erection & Commissioning of Equipment
Power Plant Maintenance & Operation
Drawing & Layouts of Projects
2. Trainee Engineer Electrical; Operation, Maintenance Electrical & New Projects Installation
Chashma Nuclear Power Plant3, 4, Chashma Plant-Pakistan December 2013 --- June 2014
Chashma Nuclear Power Plant is consist of 4 Plants Chashma1, Chashma2, Chashma3, and Chashma4. Capacity of
C1 is 325MW, C2 is 340MW, C3 is 340MW, and C4 is 340MW. It has four outgoing lines 1 is wanbachran, 2 is
Ludawala, 1 is daweed khail.
Protection & Instrumentation of 220/132/11/6.6kV GIS Grid Station.
Perform Maintenance Management like Preventive, Corrective, Predictive and Daily maintenance of
Transformer, circuit breaker, isolator, Current transformer, and Potential transformer.
Analyze and prepare the fault reports.
Efforts to minimize the breakdowns and minimize the breakdown time.
Work on protection of Electrical Power system like Line protection, Bus Bar protection, Transformer
protection, breakers protection, Battery Charger, Batteries Maintenance, Current transformer (CT),
Voltage transformer (VT), Isolators, Energy Meters, Relays, Switchgear room, and control circuits.
Annual Maintenance and testing of 220/132kV, 370MVA Auto Transformers. Test conducts are
Transformer Turns Ratio, Capacitance & Dissipation Factor (C&DF), Insulation Resistance Test, DES,
Differential Balancing, Open Circuit, Short Circuit
Annual Maintenance and testing of 220kV SF6 Circuit breakers. Test Conducts are: Contact Resistance
Test, Breaker Timing Test, SF6 Purity & Due Point Test etc.
Testing, configuration and communication of Relays like Numerical relays/digital relays/static
relays/electromechanical relays (ABB, AREVA, SIEMENS, GE).
Annual testing of all Protective Relays including Overcurrent (CDG, MCGG, ABB SPAJ 140C, Siemens
Siprotec 7SJ6005, GE Multiline MIFII), Differential Relays (DTH, D2e, 7UT612, RADSB), Distance Relay
(L3wys,LZ-96a,REL521), Restricted Earth Fault Relay, Breaker Failure, Under Frequency, Over fluxing etc
Testing of all mechanical Relays (Bucholz, Temperature gauges, Pressure Relieve Device (PRD))
Erection, Installation & commissioning of Transformers, breakers and all Grid Station related equipments.
Hands on Experience of Testing kits: Severker 780, Freja 300, Freja 306, ZFB, QZW, Megger, CT Analyzer,
Breaker Analyzer TM-1600, MOM600, Primary Injection ODEN At, CB-100 etc
Trainee Engineer; Operation & Maintenance Electrical
Hydel Power Plant Chahsma Barrage– Pakistan August 2010 --- October 2010
Chashma Hydel power Plant is Located in Punjab on Indus River at Chashma Barrage Mianwali. It Has Total 8 Units
Each Unit having 23MW Capacity his total capacity is 184 MW. Total 4 transmission lines of 220Kv, 2 line
Ludawala1 & Ludawala2 2 lines are D I Khan 1&2.
Protection & Instrumentation of 220/132/11/6.6kV Grid Station.
Perform Maintenance Management like Preventive, Corrective, Predictive and Daily maintenance of
Transformer, circuit breaker, isolator, Current transformer, and Potential transformer.
Analyze and prepare the fault reports.
Efforts to minimize the breakdowns and minimize the breakdown time.
Work on protection of Electrical Power system like Line protection, Bus Bar protection, Transformer
protection, breakers protection, Battery Charger, Batteries Maintenance, Current transformer (CT),
Voltage transformer (VT), Isolators, Energy Meters, Relays, Switchgear room, and control circuits.
Testing, configuration and communication of Relays like Numerical relays/digital relays/static
relays/electromechanical relays (ABB, AREVA, SIEMENS, and GE).
Testing of all mechanical Relays (Bucholz, Temperature gauges, Pressure Relieve Device (PRD))
Erection, Installation & commissioning of Transformers, breakers and all Grid Station related equipments.
Hands on Experience of Testing kits: Severker 780, Freja 300, Freja 306, ZFB, QZW, Megger, CT Analyzer,
Breaker Analyzer TM-1600, MOM600, Primary Injection ODEN At, CB-100 etc
TRAINING AND CERTIFICATES
3. Certificate of Participation in IEEE – Orientation & Career Development ( Held on 22nd
April, 2013at S.C.E.T
RYK)
Certificate of Participation in Annual Student Technology and Engineering Competition – 2013 ( Held on
03rd
May, 2013 at S.C.E.T RYK)
2nd
Position in Final Project Proposal Presentation by (18/20) Marks
Best Footballer Award in Swedish Cricket Premier League (Shield +Certificate)
1 Week training on Numerical Relays from Technical Services Group ()
Plant Maintenance Training at Pakistan Society For Training & Development
Middle Management and Core Development.
CKD training on pneumatic system and application.
1 week training on telecommunication system from ZTE.
EDUCATION
Islamia University Bahawalpur
B.Sc Electrical Engineering – Specialization on Power (73%)(3.23) NOV 2013
PEC # ELECT/ 43635
Safia Poly Technical Institute Mianwali
DAE Diploma of Associate Engineer Electrical August 2009
Percentage (69%)
PAEC Model College for Boyes Chashma Mianwali
Matriculation - Major in Math, Physics and Chemistry July 2006
Percentage (50%)
FINAL YEAR PROJECT
Final Project: Economical Load Scheduling Of Thermal Power Plants In Pakistan (Thesis Report)
6th
semester Mini Project : Hydro Power Plant (Working Model + Thesis Report)
2 Months Computer Applications Training (Windows + MS Office)
2 Months Typing & Composing Training (Urdu + English Composing)
COMPUTER SKILL
Computer Application
MS Office: World, Excel, Power Point.
Engineering Graphics
Engineering Graphics: Auto CAD (2D & 3D),(Knowledge)
Matlab
C++
Field Technical Software
4. DIGSI
ENERVISTA
PSW
REFRENCES
Additional information and references can be furnished on request.