Configuration of the Std22: 'BA-G2A' snapshoot at 09-02-2015 19:55:42
Tool was started at 09-02-2015 19:55:19
==============================================================================
Installed (flashed) programs (Old hardware = E00, ITC-hardware = E10):
----------------------------------------------------------------------
Sensor-pcb Prog 1: P01 E11.01
Power-pcb Prog 2: P02 E10.00
Gyro-pcb MC1 Prog 3: P03 E10.00
Gyro-pcb MC2 Prog 4: P04 E10.00
==============================================================================
Std22 Gyro System Data:
-----------------------
Watchdog counter: 000
Count all Pow_off: 001
Count Pow_off <42°: 000
Operation hours: 22379
CAN-Bus address: 015
==============================================================================
Heading and Correction values:
------------------------------
Uncorrected heading: 338.0845 °
Actual A-error: 097.7°
Speed error calculation is impossible
Speed error: +000.0°
Accelleration error: +000.0°
Sum of both errors: +000.0°
Corrected heading: 075.5°
Course over ground:
-------------------
Course from GPS: 000.0°
==============================================================================
Gyro Status:
------------
Liquid temperature >44°C: yes
Liquid temperature >51°C: no
Settling time >240 min: yes
Quick settling status: no
Test mode on: no
Any alarms: no
Any warnings: no
Any compass error: No error
Present follow up status: Follow up on
Present gyro status: Valid Course
==============================================================================
Stati and Voltages of the Outer Sphere pcb:
-------------------------------------------
Outer Sphere pcb: Status of Input Voltages: ok
MC1: System Voltage 15VDC is 14.5VDC....16VDC: ok 15.5VDC
MC1: System Voltage 23VDC is 22.5VDC....24.5VDC: ok 23.2VDC
MC1: System Voltage 15VDC is 14.7VDC....15.4VDC: ok 14.8VDC
MC1: Heater Voltage 29VDC is 24VDC....32VDC: ok 28.5VDC
MC1: DC-input for 400Hz Generator 70VDC....77VDC: ok 75.3VDC
==============================================================================
Temperature Control Condition:
------------------------------
  Comission	
  GYRO2	
  after	
  annual	
  overhaul	
  on	
  BARTOLOMEU	
  DIAS	
  Page	
  2	
  of	
  4	
  
Heater Control Loop Monitor: ok
Temperature Sensor Plausibility: ok
MC2: DC at Heating Element: 10.7VDC
Fan Current (if on): 000 mA
50°C Temperature: 49.7°C
==============================================================================
Liquid Level Monitor:
---------------------
Liquid Level at Gyro Startup (> 0.8VDC): ok 01.7VDC
Liquid Level, High or Low: High
Operation time with low liquid in minutes: 000000
==============================================================================
Outer Sphere pcb: Status of 400Hz Generator:
--------------------------------------------
Outer Sphere pcb: Status of 400Hz Generator: ok
MC2: Stabilised DC for Generator 78VDC....79.5VDC: ok 78.2VDC
MC2: 400Hz AC-voltage 50VAC....60VAC ok 54.9VAC
MC2: 400Hz AC-current 170mA....400mA ok 192mA
Startup
==============================================================================
Pump Monitor, Voltage and Current: ok
----------------------------------
MC1: Pump Voltage 23V/50Hz is 22VDC....24VDC: ok 22.9VAC
MC1: Pump Current 150mA is 140mA....170mA: ok 143mA
==============================================================================
CAN Bus Monitor and MC1 <--> MC2 Dialog:
----------------------------------------
Outer Sphere pcb: Internal CAN Bus Monitor: ok
Outer Sphere pcb: Communication MC1 with MC2: ok
Dialog Sensor pcb ---> Power pcb: ok
Dialog Power pcb ---> Sensor pcb: ok
==============================================================================
Voltages, monitored by the Power pcb:
-------------------------------------
Current of the Shaft Transformer: ok 01.8 A
Mains 24VDC Input (12VDC....40VDC): 26.2VDC
Generator Prepower (59VDC....61VDC): 60.4VDC
System-Voltage Stabilized (14VDC....15VDC): ok 14.3VDC
System-Voltage Unstabilized (20.5VDC....29.5VDC): ok 20.1VDC
Supply for Encoder (14.5VDC....15.5VDC, LED H9): ok 15.0VDC
Follow up Status and Voltage (w1 - w2): ok +002 mV
==============================================================================
Actual stored Errors and Warnings:
----------------------------------
Error Log 26 has 001 Entries
Error Log 28 has 001 Entries
Error Log 32 has 001 Entries
Error Log Legende:
------------------
Power-pcb (EL01-EL05) L15.6: stabi. DC for 400Hz off tol.
L01.1: no contact with sensor pcb L16.7: 78V for 400Hz off tolerance
L02.2: disturbed transformation L17.8: 55V/400Hz off tolerance
L03.3: voltage B5.5/8 off tolerance L18.9: gyro current off tolerance
L04.4: encoder supply off tolerance L19.10: 24V/50Hz for pump off tol.
  Comission	
  GYRO2	
  after	
  annual	
  overhaul	
  on	
  BARTOLOMEU	
  DIAS	
   Page	
  3	
  of	
  4	
  
L05.5: voltage B5.1/4 off tolerance L20.11: pump current off tolerance
L21.12: invalid temperature sensor
Sensor-pcb (EL06-EL08) L22.13: no dialog MC1 and MC2
L06.1: invalid encoder output L23.14: internal CAN-bus disturbed
L07.2: internal CAN-bus disturbed L24.15: heating control disturbed
L08.3: follow up control disturbed
Special Logs (EL25-EL27)
Connection pcb (EL09) EL 25, 26, 27: diff. Reset counters
L09.1: CAN-bus supply disturbed
Warnings (EL28-EL32)
Outer Sphere-pcb (EL10-EL24) L28.C1: fan failure
L10.1: 80 days low liquid level L29.C2: liquid heating malfunction
L11.2: voltage B21.5/8 off tolerance L30.C3: liquid temperature >60°
L12.3: 24V pump supply off tolerance L31.C4: liquid level low
L13.4: 15V for 33kHz off tolerance L32.C5: supply voltage cut off
L14.5: heater supply off tolerance -Read Errorlog with B37.7,8 up-
==============================================================================
Encoder test:
-------------
Encoder type, 12Bit or 16Bit: 16Bit type
Encodervalue, 16bit: 61546 338.0845 °
Following values in Encoder test mode only:
Encodervalue, 16bit: 00000 0 °
Number of detected errors: 00000
Encoder position at last error: 00000 0 °
Error difference, 16bit 00000 0 °
Follow up monitoring:
---------------------
ROT of the gyro: +00061 4.34484 °/min
ROT of the step motor: 000.4
ROT of the encoder: 000.0
==============================================================================
NMEA inputs (GPS and Speed):
----------------------------
Serial Communication ports monitor (Speed on B5.9/10 and GPS on B5.11/12)
(max last 20 cycles, latest is right)
Count valid Speed strings: 0 0 0 0 0
Count VHW: 0 0 0 0 0
Count VBW: 0 0 0 0 0
Count valid GPS strings: 0 0 0 0 0
Count GLL: 0 0 0 0 0
Count GGA: 0 0 0 0 0
Count VTG: 0 0 0 0 0
Count strings with valid checksum: 0 0 0 0 0
DDU = yes(if DDU = yes then indicated speed values are invalid)
Speed type detected value status remarks
---------------------------------------------------------------
Pulselog no +000.0kn
NMEA VHW no +000.0kn
NMEA VTG no +000.0kn
NMEA VBW W no +000.0kn
NMEA VHW B no +000.0kn
CAN-Bus Spd. no +000.0kn Used
CMG = 000.0° from VTG at gyro
Status of Latitude: ok
Used latitude value (decimal): 000.0°
  Comission	
  GYRO2	
  after	
  annual	
  overhaul	
  on	
  BARTOLOMEU	
  DIAS	
  Page	
  4	
  of	
  4	
  
North speed = +000.0kn based on CMG (1. priority) or Gyro
==============================================================================
Errors of the int. CAN-Bus Driver (max last 9 cycles, latest is right):
------------------------------------------------------------------------
Delay until next valid telegram:
0000 0000 0000 0000 0000 0000
Operation status:
CAN ok CAN ok CAN ok CAN ok CAN ok CAN ok
Number of receive interrupts:
000000 000005 000005 000005 000005 000005
Number of CAN warnings:
000000 000929 000929 000929 000929 000929
Number of passive states:
000000 000000 000000 000000 000000 000000
Number of CAN errors:
000000 000000 000000 000000 000000 000000
Number of receive errors:
000 000 000 000 000 000
Number of transmit errors:
000 000 006 000 000 000
==============================================================================
Configuration Parameters in the FRAM:
-------------------------------------
Speed type configuration (B37.4):
---------------------------------
Pulselog NMEA - VHW NMEA - VTG NMEA - VBWW NMEA - VBWG
x
Pulselog direction: open contact at B5.6-7 is astern speed.
Heading output configuration (B37.1,2,3):
-----------------------------------------
Channel1 B2 Channel2 B3 Output3 B4
NMEA NMEA CBus
Speed error correction (SEC) = enabled
Rate of turn polarity: clockwise = positiv
Gyro connected by CAN-Bus to a DU = yes
NMEA outputs B2 and B3 correction = corrected
NMEA channel configuration (B37.2):
-----------------------------------
NMEA repetition time: 1sec
Selected NMEA sentences: HDT + ROT
*************************** END OF ONE HARDCOPY **************************

Weitere ähnliche Inhalte

Was ist angesagt?

Advanced motion controls az25a20ddc
Advanced motion controls az25a20ddcAdvanced motion controls az25a20ddc
Advanced motion controls az25a20ddcElectromate
 
Advanced motion controls az40a8ddc
Advanced motion controls az40a8ddcAdvanced motion controls az40a8ddc
Advanced motion controls az40a8ddcElectromate
 
2 Sed2 Drive Applications
2 Sed2 Drive Applications2 Sed2 Drive Applications
2 Sed2 Drive Applicationscarlhasselbring
 
Advanced motion controls azbdc25a20
Advanced motion controls azbdc25a20Advanced motion controls azbdc25a20
Advanced motion controls azbdc25a20Electromate
 
Advanced motion controls azbdc60a8
Advanced motion controls azbdc60a8Advanced motion controls azbdc60a8
Advanced motion controls azbdc60a8Electromate
 
Advanced motion controls azbdc40a8
Advanced motion controls azbdc40a8Advanced motion controls azbdc40a8
Advanced motion controls azbdc40a8Electromate
 
Advanced motion controls az25a20
Advanced motion controls az25a20Advanced motion controls az25a20
Advanced motion controls az25a20Electromate
 
VltFC 102 hvac drive operating instructions
VltFC 102  hvac drive  operating instructionsVltFC 102  hvac drive  operating instructions
VltFC 102 hvac drive operating instructionsToàn Huỳnh
 
Applied motion products stac6 datasheet
Applied motion products stac6 datasheetApplied motion products stac6 datasheet
Applied motion products stac6 datasheetElectromate
 
Advanced motion controls azbdc10a20
Advanced motion controls azbdc10a20Advanced motion controls azbdc10a20
Advanced motion controls azbdc10a20Electromate
 
Advanced motion controls az20a8ddc
Advanced motion controls az20a8ddcAdvanced motion controls az20a8ddc
Advanced motion controls az20a8ddcElectromate
 
Advanced motion controls azb25a20
Advanced motion controls azb25a20Advanced motion controls azb25a20
Advanced motion controls azb25a20Electromate
 
Advanced motion controls azxbe6c20
Advanced motion controls azxbe6c20Advanced motion controls azxbe6c20
Advanced motion controls azxbe6c20Electromate
 
Electrocraft pro a08_v48_datasheet
Electrocraft pro a08_v48_datasheetElectrocraft pro a08_v48_datasheet
Electrocraft pro a08_v48_datasheetElectromate
 
Advanced motion controls azb40a8
Advanced motion controls azb40a8Advanced motion controls azb40a8
Advanced motion controls azb40a8Electromate
 
Advanced motion controls az60a8
Advanced motion controls az60a8Advanced motion controls az60a8
Advanced motion controls az60a8Electromate
 
CMEL 2.4 inch Amoled(240x320) Datasheet
CMEL 2.4 inch Amoled(240x320) DatasheetCMEL 2.4 inch Amoled(240x320) Datasheet
CMEL 2.4 inch Amoled(240x320) DatasheetPanox Display
 
Advanced motion controls azbdc6a8
Advanced motion controls azbdc6a8Advanced motion controls azbdc6a8
Advanced motion controls azbdc6a8Electromate
 

Was ist angesagt? (19)

Advanced motion controls az25a20ddc
Advanced motion controls az25a20ddcAdvanced motion controls az25a20ddc
Advanced motion controls az25a20ddc
 
Advanced motion controls az40a8ddc
Advanced motion controls az40a8ddcAdvanced motion controls az40a8ddc
Advanced motion controls az40a8ddc
 
2 Sed2 Drive Applications
2 Sed2 Drive Applications2 Sed2 Drive Applications
2 Sed2 Drive Applications
 
Advanced motion controls azbdc25a20
Advanced motion controls azbdc25a20Advanced motion controls azbdc25a20
Advanced motion controls azbdc25a20
 
Advanced motion controls azbdc60a8
Advanced motion controls azbdc60a8Advanced motion controls azbdc60a8
Advanced motion controls azbdc60a8
 
Advanced motion controls azbdc40a8
Advanced motion controls azbdc40a8Advanced motion controls azbdc40a8
Advanced motion controls azbdc40a8
 
Advanced motion controls az25a20
Advanced motion controls az25a20Advanced motion controls az25a20
Advanced motion controls az25a20
 
VltFC 102 hvac drive operating instructions
VltFC 102  hvac drive  operating instructionsVltFC 102  hvac drive  operating instructions
VltFC 102 hvac drive operating instructions
 
Applied motion products stac6 datasheet
Applied motion products stac6 datasheetApplied motion products stac6 datasheet
Applied motion products stac6 datasheet
 
Advanced motion controls azbdc10a20
Advanced motion controls azbdc10a20Advanced motion controls azbdc10a20
Advanced motion controls azbdc10a20
 
Advanced motion controls az20a8ddc
Advanced motion controls az20a8ddcAdvanced motion controls az20a8ddc
Advanced motion controls az20a8ddc
 
Advanced motion controls azb25a20
Advanced motion controls azb25a20Advanced motion controls azb25a20
Advanced motion controls azb25a20
 
Advanced motion controls azxbe6c20
Advanced motion controls azxbe6c20Advanced motion controls azxbe6c20
Advanced motion controls azxbe6c20
 
Electrocraft pro a08_v48_datasheet
Electrocraft pro a08_v48_datasheetElectrocraft pro a08_v48_datasheet
Electrocraft pro a08_v48_datasheet
 
Advanced motion controls azb40a8
Advanced motion controls azb40a8Advanced motion controls azb40a8
Advanced motion controls azb40a8
 
Advanced motion controls az60a8
Advanced motion controls az60a8Advanced motion controls az60a8
Advanced motion controls az60a8
 
CMEL 2.4 inch Amoled(240x320) Datasheet
CMEL 2.4 inch Amoled(240x320) DatasheetCMEL 2.4 inch Amoled(240x320) Datasheet
CMEL 2.4 inch Amoled(240x320) Datasheet
 
Advanced motion controls azbdc6a8
Advanced motion controls azbdc6a8Advanced motion controls azbdc6a8
Advanced motion controls azbdc6a8
 
Vlt aqua fc 202
Vlt aqua fc 202Vlt aqua fc 202
Vlt aqua fc 202
 

Andere mochten auch

Andere mochten auch (16)

SLE
SLESLE
SLE
 
Abortion
AbortionAbortion
Abortion
 
SWISS BULLION
SWISS BULLIONSWISS BULLION
SWISS BULLION
 
SWISS BULLION
SWISS BULLIONSWISS BULLION
SWISS BULLION
 
Updated Tables as of Aug.22, 2015
Updated Tables as of Aug.22, 2015Updated Tables as of Aug.22, 2015
Updated Tables as of Aug.22, 2015
 
Infoeme cr LABORATORIO
Infoeme cr LABORATORIOInfoeme cr LABORATORIO
Infoeme cr LABORATORIO
 
Enterprise Software Solution Provider
Enterprise Software Solution ProviderEnterprise Software Solution Provider
Enterprise Software Solution Provider
 
Aset lki baru 2015
Aset lki baru 2015Aset lki baru 2015
Aset lki baru 2015
 
PII_&_RM_Market Update-Summer-2016-web
PII_&_RM_Market Update-Summer-2016-webPII_&_RM_Market Update-Summer-2016-web
PII_&_RM_Market Update-Summer-2016-web
 
Accessing IDT Scheduler Online (2)
Accessing IDT Scheduler Online (2)Accessing IDT Scheduler Online (2)
Accessing IDT Scheduler Online (2)
 
RESUME
RESUMERESUME
RESUME
 
Yoga posen booklet_es_o12
Yoga posen booklet_es_o12Yoga posen booklet_es_o12
Yoga posen booklet_es_o12
 
DERECHOS DE AUTOR
DERECHOS DE AUTORDERECHOS DE AUTOR
DERECHOS DE AUTOR
 
What's good in having a blog
What's good in having a blogWhat's good in having a blog
What's good in having a blog
 
AkshaySheteResume
AkshaySheteResumeAkshaySheteResume
AkshaySheteResume
 
Product Planning Summer Presentation.
Product Planning Summer Presentation.Product Planning Summer Presentation.
Product Planning Summer Presentation.
 

Ähnlich wie overviev gyrocompass parameters

Critical Conduction Mode (CRM) PFC Circuit
Critical Conduction Mode (CRM) PFC CircuitCritical Conduction Mode (CRM) PFC Circuit
Critical Conduction Mode (CRM) PFC CircuitTsuyoshi Horigome
 
電流臨界モード方式PFC制御回路の解説書
電流臨界モード方式PFC制御回路の解説書電流臨界モード方式PFC制御回路の解説書
電流臨界モード方式PFC制御回路の解説書spicepark
 
Cataloge ge 3.control and_automation-27_vat300_e_c7_rev_c
Cataloge ge 3.control and_automation-27_vat300_e_c7_rev_cCataloge ge 3.control and_automation-27_vat300_e_c7_rev_c
Cataloge ge 3.control and_automation-27_vat300_e_c7_rev_cThuan Kieu
 
Quick guide aqua fc 200
Quick guide aqua fc 200Quick guide aqua fc 200
Quick guide aqua fc 200Toàn Huỳnh
 
F5 m instruction manual
F5 m instruction manualF5 m instruction manual
F5 m instruction manualToàn Huỳnh
 
Critical Conduction Mode (CRM) PFC Circuit
Critical Conduction Mode (CRM) PFC CircuitCritical Conduction Mode (CRM) PFC Circuit
Critical Conduction Mode (CRM) PFC CircuitTsuyoshi Horigome
 
187787508-Over-Current-Earth-Fault-Setting-Calculations.pdf
187787508-Over-Current-Earth-Fault-Setting-Calculations.pdf187787508-Over-Current-Earth-Fault-Setting-Calculations.pdf
187787508-Over-Current-Earth-Fault-Setting-Calculations.pdfChadWood16
 
187787508-Over-Current-Earth-Fault-Setting-Calculations.pdf
187787508-Over-Current-Earth-Fault-Setting-Calculations.pdf187787508-Over-Current-Earth-Fault-Setting-Calculations.pdf
187787508-Over-Current-Earth-Fault-Setting-Calculations.pdfAhmadHamouda3
 
Intelligent mcc Siemens
Intelligent mcc Siemens Intelligent mcc Siemens
Intelligent mcc Siemens Praveen Patil
 
Steam turbine china
Steam turbine chinaSteam turbine china
Steam turbine chinaAndri Yanto
 
CAN_controller_integrated_transceiver_microchip_MCP25625.pdf
CAN_controller_integrated_transceiver_microchip_MCP25625.pdfCAN_controller_integrated_transceiver_microchip_MCP25625.pdf
CAN_controller_integrated_transceiver_microchip_MCP25625.pdfVaraPrasadVemula4
 
Kaizen55 pa plus final round ver emd2
Kaizen55 pa plus final round ver emd2Kaizen55 pa plus final round ver emd2
Kaizen55 pa plus final round ver emd2Kanoksak Chaimeeboon
 
Stepping Motor Driver IC Using PWM Chopper Type: TB62209FG
Stepping Motor Driver IC Using PWM Chopper Type: TB62209FGStepping Motor Driver IC Using PWM Chopper Type: TB62209FG
Stepping Motor Driver IC Using PWM Chopper Type: TB62209FGPremier Farnell
 
VLSID 2015 FirmLeak (Poster)
VLSID 2015 FirmLeak (Poster)VLSID 2015 FirmLeak (Poster)
VLSID 2015 FirmLeak (Poster)Anand Haridass
 
AVR_GENERAL KOSTI.ppt
AVR_GENERAL KOSTI.pptAVR_GENERAL KOSTI.ppt
AVR_GENERAL KOSTI.pptprasadkappala
 
Advanced motion controls dc201r25a20nac
Advanced motion controls dc201r25a20nacAdvanced motion controls dc201r25a20nac
Advanced motion controls dc201r25a20nacElectromate
 

Ähnlich wie overviev gyrocompass parameters (20)

Critical Conduction Mode (CRM) PFC Circuit
Critical Conduction Mode (CRM) PFC CircuitCritical Conduction Mode (CRM) PFC Circuit
Critical Conduction Mode (CRM) PFC Circuit
 
電流臨界モード方式PFC制御回路の解説書
電流臨界モード方式PFC制御回路の解説書電流臨界モード方式PFC制御回路の解説書
電流臨界モード方式PFC制御回路の解説書
 
Cataloge ge 3.control and_automation-27_vat300_e_c7_rev_c
Cataloge ge 3.control and_automation-27_vat300_e_c7_rev_cCataloge ge 3.control and_automation-27_vat300_e_c7_rev_c
Cataloge ge 3.control and_automation-27_vat300_e_c7_rev_c
 
Quick guide aqua fc 200
Quick guide aqua fc 200Quick guide aqua fc 200
Quick guide aqua fc 200
 
Quick guide Danfoss aqua fc 200
Quick guide Danfoss aqua fc 200Quick guide Danfoss aqua fc 200
Quick guide Danfoss aqua fc 200
 
F5 m instruction manual
F5 m instruction manualF5 m instruction manual
F5 m instruction manual
 
Critical Conduction Mode (CRM) PFC Circuit
Critical Conduction Mode (CRM) PFC CircuitCritical Conduction Mode (CRM) PFC Circuit
Critical Conduction Mode (CRM) PFC Circuit
 
187787508-Over-Current-Earth-Fault-Setting-Calculations.pdf
187787508-Over-Current-Earth-Fault-Setting-Calculations.pdf187787508-Over-Current-Earth-Fault-Setting-Calculations.pdf
187787508-Over-Current-Earth-Fault-Setting-Calculations.pdf
 
187787508-Over-Current-Earth-Fault-Setting-Calculations.pdf
187787508-Over-Current-Earth-Fault-Setting-Calculations.pdf187787508-Over-Current-Earth-Fault-Setting-Calculations.pdf
187787508-Over-Current-Earth-Fault-Setting-Calculations.pdf
 
Intelligent mcc Siemens
Intelligent mcc Siemens Intelligent mcc Siemens
Intelligent mcc Siemens
 
Steam turbine china
Steam turbine chinaSteam turbine china
Steam turbine china
 
CAN_controller_integrated_transceiver_microchip_MCP25625.pdf
CAN_controller_integrated_transceiver_microchip_MCP25625.pdfCAN_controller_integrated_transceiver_microchip_MCP25625.pdf
CAN_controller_integrated_transceiver_microchip_MCP25625.pdf
 
ad590 datasheet
ad590 datasheetad590 datasheet
ad590 datasheet
 
Kaizen55 pa plus final round ver emd2
Kaizen55 pa plus final round ver emd2Kaizen55 pa plus final round ver emd2
Kaizen55 pa plus final round ver emd2
 
Stepping Motor Driver IC Using PWM Chopper Type: TB62209FG
Stepping Motor Driver IC Using PWM Chopper Type: TB62209FGStepping Motor Driver IC Using PWM Chopper Type: TB62209FG
Stepping Motor Driver IC Using PWM Chopper Type: TB62209FG
 
Cd00003612
Cd00003612Cd00003612
Cd00003612
 
VLSID 2015 FirmLeak (Poster)
VLSID 2015 FirmLeak (Poster)VLSID 2015 FirmLeak (Poster)
VLSID 2015 FirmLeak (Poster)
 
AVR_GENERAL KOSTI.ppt
AVR_GENERAL KOSTI.pptAVR_GENERAL KOSTI.ppt
AVR_GENERAL KOSTI.ppt
 
Intelligent mcc
Intelligent mccIntelligent mcc
Intelligent mcc
 
Advanced motion controls dc201r25a20nac
Advanced motion controls dc201r25a20nacAdvanced motion controls dc201r25a20nac
Advanced motion controls dc201r25a20nac
 

Kürzlich hochgeladen

Mastering the Unannounced Regulatory Inspection
Mastering the Unannounced Regulatory InspectionMastering the Unannounced Regulatory Inspection
Mastering the Unannounced Regulatory InspectionSafetyChain Software
 
Student login on Anyboli platform.helpin
Student login on Anyboli platform.helpinStudent login on Anyboli platform.helpin
Student login on Anyboli platform.helpinRaunakKeshri1
 
Presentation by Andreas Schleicher Tackling the School Absenteeism Crisis 30 ...
Presentation by Andreas Schleicher Tackling the School Absenteeism Crisis 30 ...Presentation by Andreas Schleicher Tackling the School Absenteeism Crisis 30 ...
Presentation by Andreas Schleicher Tackling the School Absenteeism Crisis 30 ...EduSkills OECD
 
JAPAN: ORGANISATION OF PMDA, PHARMACEUTICAL LAWS & REGULATIONS, TYPES OF REGI...
JAPAN: ORGANISATION OF PMDA, PHARMACEUTICAL LAWS & REGULATIONS, TYPES OF REGI...JAPAN: ORGANISATION OF PMDA, PHARMACEUTICAL LAWS & REGULATIONS, TYPES OF REGI...
JAPAN: ORGANISATION OF PMDA, PHARMACEUTICAL LAWS & REGULATIONS, TYPES OF REGI...anjaliyadav012327
 
Sanyam Choudhary Chemistry practical.pdf
Sanyam Choudhary Chemistry practical.pdfSanyam Choudhary Chemistry practical.pdf
Sanyam Choudhary Chemistry practical.pdfsanyamsingh5019
 
BASLIQ CURRENT LOOKBOOK LOOKBOOK(1) (1).pdf
BASLIQ CURRENT LOOKBOOK  LOOKBOOK(1) (1).pdfBASLIQ CURRENT LOOKBOOK  LOOKBOOK(1) (1).pdf
BASLIQ CURRENT LOOKBOOK LOOKBOOK(1) (1).pdfSoniaTolstoy
 
Paris 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activityParis 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activityGeoBlogs
 
Web & Social Media Analytics Previous Year Question Paper.pdf
Web & Social Media Analytics Previous Year Question Paper.pdfWeb & Social Media Analytics Previous Year Question Paper.pdf
Web & Social Media Analytics Previous Year Question Paper.pdfJayanti Pande
 
Russian Call Girls in Andheri Airport Mumbai WhatsApp 9167673311 💞 Full Nigh...
Russian Call Girls in Andheri Airport Mumbai WhatsApp  9167673311 💞 Full Nigh...Russian Call Girls in Andheri Airport Mumbai WhatsApp  9167673311 💞 Full Nigh...
Russian Call Girls in Andheri Airport Mumbai WhatsApp 9167673311 💞 Full Nigh...Pooja Nehwal
 
Introduction to Nonprofit Accounting: The Basics
Introduction to Nonprofit Accounting: The BasicsIntroduction to Nonprofit Accounting: The Basics
Introduction to Nonprofit Accounting: The BasicsTechSoup
 
Activity 01 - Artificial Culture (1).pdf
Activity 01 - Artificial Culture (1).pdfActivity 01 - Artificial Culture (1).pdf
Activity 01 - Artificial Culture (1).pdfciinovamais
 
The basics of sentences session 2pptx copy.pptx
The basics of sentences session 2pptx copy.pptxThe basics of sentences session 2pptx copy.pptx
The basics of sentences session 2pptx copy.pptxheathfieldcps1
 
Measures of Central Tendency: Mean, Median and Mode
Measures of Central Tendency: Mean, Median and ModeMeasures of Central Tendency: Mean, Median and Mode
Measures of Central Tendency: Mean, Median and ModeThiyagu K
 
Ecosystem Interactions Class Discussion Presentation in Blue Green Lined Styl...
Ecosystem Interactions Class Discussion Presentation in Blue Green Lined Styl...Ecosystem Interactions Class Discussion Presentation in Blue Green Lined Styl...
Ecosystem Interactions Class Discussion Presentation in Blue Green Lined Styl...fonyou31
 
9548086042 for call girls in Indira Nagar with room service
9548086042  for call girls in Indira Nagar  with room service9548086042  for call girls in Indira Nagar  with room service
9548086042 for call girls in Indira Nagar with room servicediscovermytutordmt
 
Measures of Dispersion and Variability: Range, QD, AD and SD
Measures of Dispersion and Variability: Range, QD, AD and SDMeasures of Dispersion and Variability: Range, QD, AD and SD
Measures of Dispersion and Variability: Range, QD, AD and SDThiyagu K
 
Beyond the EU: DORA and NIS 2 Directive's Global Impact
Beyond the EU: DORA and NIS 2 Directive's Global ImpactBeyond the EU: DORA and NIS 2 Directive's Global Impact
Beyond the EU: DORA and NIS 2 Directive's Global ImpactPECB
 
social pharmacy d-pharm 1st year by Pragati K. Mahajan
social pharmacy d-pharm 1st year by Pragati K. Mahajansocial pharmacy d-pharm 1st year by Pragati K. Mahajan
social pharmacy d-pharm 1st year by Pragati K. Mahajanpragatimahajan3
 

Kürzlich hochgeladen (20)

Mastering the Unannounced Regulatory Inspection
Mastering the Unannounced Regulatory InspectionMastering the Unannounced Regulatory Inspection
Mastering the Unannounced Regulatory Inspection
 
Student login on Anyboli platform.helpin
Student login on Anyboli platform.helpinStudent login on Anyboli platform.helpin
Student login on Anyboli platform.helpin
 
Presentation by Andreas Schleicher Tackling the School Absenteeism Crisis 30 ...
Presentation by Andreas Schleicher Tackling the School Absenteeism Crisis 30 ...Presentation by Andreas Schleicher Tackling the School Absenteeism Crisis 30 ...
Presentation by Andreas Schleicher Tackling the School Absenteeism Crisis 30 ...
 
JAPAN: ORGANISATION OF PMDA, PHARMACEUTICAL LAWS & REGULATIONS, TYPES OF REGI...
JAPAN: ORGANISATION OF PMDA, PHARMACEUTICAL LAWS & REGULATIONS, TYPES OF REGI...JAPAN: ORGANISATION OF PMDA, PHARMACEUTICAL LAWS & REGULATIONS, TYPES OF REGI...
JAPAN: ORGANISATION OF PMDA, PHARMACEUTICAL LAWS & REGULATIONS, TYPES OF REGI...
 
Sanyam Choudhary Chemistry practical.pdf
Sanyam Choudhary Chemistry practical.pdfSanyam Choudhary Chemistry practical.pdf
Sanyam Choudhary Chemistry practical.pdf
 
BASLIQ CURRENT LOOKBOOK LOOKBOOK(1) (1).pdf
BASLIQ CURRENT LOOKBOOK  LOOKBOOK(1) (1).pdfBASLIQ CURRENT LOOKBOOK  LOOKBOOK(1) (1).pdf
BASLIQ CURRENT LOOKBOOK LOOKBOOK(1) (1).pdf
 
Advance Mobile Application Development class 07
Advance Mobile Application Development class 07Advance Mobile Application Development class 07
Advance Mobile Application Development class 07
 
Paris 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activityParis 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activity
 
Web & Social Media Analytics Previous Year Question Paper.pdf
Web & Social Media Analytics Previous Year Question Paper.pdfWeb & Social Media Analytics Previous Year Question Paper.pdf
Web & Social Media Analytics Previous Year Question Paper.pdf
 
Russian Call Girls in Andheri Airport Mumbai WhatsApp 9167673311 💞 Full Nigh...
Russian Call Girls in Andheri Airport Mumbai WhatsApp  9167673311 💞 Full Nigh...Russian Call Girls in Andheri Airport Mumbai WhatsApp  9167673311 💞 Full Nigh...
Russian Call Girls in Andheri Airport Mumbai WhatsApp 9167673311 💞 Full Nigh...
 
Introduction to Nonprofit Accounting: The Basics
Introduction to Nonprofit Accounting: The BasicsIntroduction to Nonprofit Accounting: The Basics
Introduction to Nonprofit Accounting: The Basics
 
Activity 01 - Artificial Culture (1).pdf
Activity 01 - Artificial Culture (1).pdfActivity 01 - Artificial Culture (1).pdf
Activity 01 - Artificial Culture (1).pdf
 
The basics of sentences session 2pptx copy.pptx
The basics of sentences session 2pptx copy.pptxThe basics of sentences session 2pptx copy.pptx
The basics of sentences session 2pptx copy.pptx
 
Measures of Central Tendency: Mean, Median and Mode
Measures of Central Tendency: Mean, Median and ModeMeasures of Central Tendency: Mean, Median and Mode
Measures of Central Tendency: Mean, Median and Mode
 
Ecosystem Interactions Class Discussion Presentation in Blue Green Lined Styl...
Ecosystem Interactions Class Discussion Presentation in Blue Green Lined Styl...Ecosystem Interactions Class Discussion Presentation in Blue Green Lined Styl...
Ecosystem Interactions Class Discussion Presentation in Blue Green Lined Styl...
 
9548086042 for call girls in Indira Nagar with room service
9548086042  for call girls in Indira Nagar  with room service9548086042  for call girls in Indira Nagar  with room service
9548086042 for call girls in Indira Nagar with room service
 
Measures of Dispersion and Variability: Range, QD, AD and SD
Measures of Dispersion and Variability: Range, QD, AD and SDMeasures of Dispersion and Variability: Range, QD, AD and SD
Measures of Dispersion and Variability: Range, QD, AD and SD
 
Beyond the EU: DORA and NIS 2 Directive's Global Impact
Beyond the EU: DORA and NIS 2 Directive's Global ImpactBeyond the EU: DORA and NIS 2 Directive's Global Impact
Beyond the EU: DORA and NIS 2 Directive's Global Impact
 
Código Creativo y Arte de Software | Unidad 1
Código Creativo y Arte de Software | Unidad 1Código Creativo y Arte de Software | Unidad 1
Código Creativo y Arte de Software | Unidad 1
 
social pharmacy d-pharm 1st year by Pragati K. Mahajan
social pharmacy d-pharm 1st year by Pragati K. Mahajansocial pharmacy d-pharm 1st year by Pragati K. Mahajan
social pharmacy d-pharm 1st year by Pragati K. Mahajan
 

overviev gyrocompass parameters

  • 1.   Comission  GYRO2  after  annual  overhaul  on  BARTOLOMEU  DIAS   Page  1  of  4   Configuration of the Std22: 'BA-G2A' snapshoot at 09-02-2015 19:55:42 Tool was started at 09-02-2015 19:55:19 ============================================================================== Installed (flashed) programs (Old hardware = E00, ITC-hardware = E10): ---------------------------------------------------------------------- Sensor-pcb Prog 1: P01 E11.01 Power-pcb Prog 2: P02 E10.00 Gyro-pcb MC1 Prog 3: P03 E10.00 Gyro-pcb MC2 Prog 4: P04 E10.00 ============================================================================== Std22 Gyro System Data: ----------------------- Watchdog counter: 000 Count all Pow_off: 001 Count Pow_off <42°: 000 Operation hours: 22379 CAN-Bus address: 015 ============================================================================== Heading and Correction values: ------------------------------ Uncorrected heading: 338.0845 ° Actual A-error: 097.7° Speed error calculation is impossible Speed error: +000.0° Accelleration error: +000.0° Sum of both errors: +000.0° Corrected heading: 075.5° Course over ground: ------------------- Course from GPS: 000.0° ============================================================================== Gyro Status: ------------ Liquid temperature >44°C: yes Liquid temperature >51°C: no Settling time >240 min: yes Quick settling status: no Test mode on: no Any alarms: no Any warnings: no Any compass error: No error Present follow up status: Follow up on Present gyro status: Valid Course ============================================================================== Stati and Voltages of the Outer Sphere pcb: ------------------------------------------- Outer Sphere pcb: Status of Input Voltages: ok MC1: System Voltage 15VDC is 14.5VDC....16VDC: ok 15.5VDC MC1: System Voltage 23VDC is 22.5VDC....24.5VDC: ok 23.2VDC MC1: System Voltage 15VDC is 14.7VDC....15.4VDC: ok 14.8VDC MC1: Heater Voltage 29VDC is 24VDC....32VDC: ok 28.5VDC MC1: DC-input for 400Hz Generator 70VDC....77VDC: ok 75.3VDC ============================================================================== Temperature Control Condition: ------------------------------
  • 2.   Comission  GYRO2  after  annual  overhaul  on  BARTOLOMEU  DIAS  Page  2  of  4   Heater Control Loop Monitor: ok Temperature Sensor Plausibility: ok MC2: DC at Heating Element: 10.7VDC Fan Current (if on): 000 mA 50°C Temperature: 49.7°C ============================================================================== Liquid Level Monitor: --------------------- Liquid Level at Gyro Startup (> 0.8VDC): ok 01.7VDC Liquid Level, High or Low: High Operation time with low liquid in minutes: 000000 ============================================================================== Outer Sphere pcb: Status of 400Hz Generator: -------------------------------------------- Outer Sphere pcb: Status of 400Hz Generator: ok MC2: Stabilised DC for Generator 78VDC....79.5VDC: ok 78.2VDC MC2: 400Hz AC-voltage 50VAC....60VAC ok 54.9VAC MC2: 400Hz AC-current 170mA....400mA ok 192mA Startup ============================================================================== Pump Monitor, Voltage and Current: ok ---------------------------------- MC1: Pump Voltage 23V/50Hz is 22VDC....24VDC: ok 22.9VAC MC1: Pump Current 150mA is 140mA....170mA: ok 143mA ============================================================================== CAN Bus Monitor and MC1 <--> MC2 Dialog: ---------------------------------------- Outer Sphere pcb: Internal CAN Bus Monitor: ok Outer Sphere pcb: Communication MC1 with MC2: ok Dialog Sensor pcb ---> Power pcb: ok Dialog Power pcb ---> Sensor pcb: ok ============================================================================== Voltages, monitored by the Power pcb: ------------------------------------- Current of the Shaft Transformer: ok 01.8 A Mains 24VDC Input (12VDC....40VDC): 26.2VDC Generator Prepower (59VDC....61VDC): 60.4VDC System-Voltage Stabilized (14VDC....15VDC): ok 14.3VDC System-Voltage Unstabilized (20.5VDC....29.5VDC): ok 20.1VDC Supply for Encoder (14.5VDC....15.5VDC, LED H9): ok 15.0VDC Follow up Status and Voltage (w1 - w2): ok +002 mV ============================================================================== Actual stored Errors and Warnings: ---------------------------------- Error Log 26 has 001 Entries Error Log 28 has 001 Entries Error Log 32 has 001 Entries Error Log Legende: ------------------ Power-pcb (EL01-EL05) L15.6: stabi. DC for 400Hz off tol. L01.1: no contact with sensor pcb L16.7: 78V for 400Hz off tolerance L02.2: disturbed transformation L17.8: 55V/400Hz off tolerance L03.3: voltage B5.5/8 off tolerance L18.9: gyro current off tolerance L04.4: encoder supply off tolerance L19.10: 24V/50Hz for pump off tol.
  • 3.   Comission  GYRO2  after  annual  overhaul  on  BARTOLOMEU  DIAS   Page  3  of  4   L05.5: voltage B5.1/4 off tolerance L20.11: pump current off tolerance L21.12: invalid temperature sensor Sensor-pcb (EL06-EL08) L22.13: no dialog MC1 and MC2 L06.1: invalid encoder output L23.14: internal CAN-bus disturbed L07.2: internal CAN-bus disturbed L24.15: heating control disturbed L08.3: follow up control disturbed Special Logs (EL25-EL27) Connection pcb (EL09) EL 25, 26, 27: diff. Reset counters L09.1: CAN-bus supply disturbed Warnings (EL28-EL32) Outer Sphere-pcb (EL10-EL24) L28.C1: fan failure L10.1: 80 days low liquid level L29.C2: liquid heating malfunction L11.2: voltage B21.5/8 off tolerance L30.C3: liquid temperature >60° L12.3: 24V pump supply off tolerance L31.C4: liquid level low L13.4: 15V for 33kHz off tolerance L32.C5: supply voltage cut off L14.5: heater supply off tolerance -Read Errorlog with B37.7,8 up- ============================================================================== Encoder test: ------------- Encoder type, 12Bit or 16Bit: 16Bit type Encodervalue, 16bit: 61546 338.0845 ° Following values in Encoder test mode only: Encodervalue, 16bit: 00000 0 ° Number of detected errors: 00000 Encoder position at last error: 00000 0 ° Error difference, 16bit 00000 0 ° Follow up monitoring: --------------------- ROT of the gyro: +00061 4.34484 °/min ROT of the step motor: 000.4 ROT of the encoder: 000.0 ============================================================================== NMEA inputs (GPS and Speed): ---------------------------- Serial Communication ports monitor (Speed on B5.9/10 and GPS on B5.11/12) (max last 20 cycles, latest is right) Count valid Speed strings: 0 0 0 0 0 Count VHW: 0 0 0 0 0 Count VBW: 0 0 0 0 0 Count valid GPS strings: 0 0 0 0 0 Count GLL: 0 0 0 0 0 Count GGA: 0 0 0 0 0 Count VTG: 0 0 0 0 0 Count strings with valid checksum: 0 0 0 0 0 DDU = yes(if DDU = yes then indicated speed values are invalid) Speed type detected value status remarks --------------------------------------------------------------- Pulselog no +000.0kn NMEA VHW no +000.0kn NMEA VTG no +000.0kn NMEA VBW W no +000.0kn NMEA VHW B no +000.0kn CAN-Bus Spd. no +000.0kn Used CMG = 000.0° from VTG at gyro Status of Latitude: ok Used latitude value (decimal): 000.0°
  • 4.   Comission  GYRO2  after  annual  overhaul  on  BARTOLOMEU  DIAS  Page  4  of  4   North speed = +000.0kn based on CMG (1. priority) or Gyro ============================================================================== Errors of the int. CAN-Bus Driver (max last 9 cycles, latest is right): ------------------------------------------------------------------------ Delay until next valid telegram: 0000 0000 0000 0000 0000 0000 Operation status: CAN ok CAN ok CAN ok CAN ok CAN ok CAN ok Number of receive interrupts: 000000 000005 000005 000005 000005 000005 Number of CAN warnings: 000000 000929 000929 000929 000929 000929 Number of passive states: 000000 000000 000000 000000 000000 000000 Number of CAN errors: 000000 000000 000000 000000 000000 000000 Number of receive errors: 000 000 000 000 000 000 Number of transmit errors: 000 000 006 000 000 000 ============================================================================== Configuration Parameters in the FRAM: ------------------------------------- Speed type configuration (B37.4): --------------------------------- Pulselog NMEA - VHW NMEA - VTG NMEA - VBWW NMEA - VBWG x Pulselog direction: open contact at B5.6-7 is astern speed. Heading output configuration (B37.1,2,3): ----------------------------------------- Channel1 B2 Channel2 B3 Output3 B4 NMEA NMEA CBus Speed error correction (SEC) = enabled Rate of turn polarity: clockwise = positiv Gyro connected by CAN-Bus to a DU = yes NMEA outputs B2 and B3 correction = corrected NMEA channel configuration (B37.2): ----------------------------------- NMEA repetition time: 1sec Selected NMEA sentences: HDT + ROT *************************** END OF ONE HARDCOPY **************************