Reduce re-energisation time
for your electricity customers
Introducing a cost-effective self-healing
solution for underground open-loop networks
Under
30 seconds
That’s how fast our underground
self-healing solution restores
power to healthy areas of
a distribution network
A simpler way to boost grid availability and reliability
Operating an electrical distribution grid is an increasingly complex
business. The challenges posed by growing demand, integration
of distributed generation resources, and ageing infrastructure – to
name just a few – all have an effect on overall grid reliability, and on
customer satisfaction.
Grid operators need to face these challenges in order to boost
efficiency, protect their customers and avoid regulatory scrutiny,
but it’s not easy. Most solutions that reduce the frequency and
duration of power outages also require large capital expenditures,
complicated installation of new equipment, and can take years
to implement.
There is another option, though – a self-healing network
solution from Schneider Electric. This is a smart, cost-effective
way to enhance the reliability of underground electrical distribution
grids. Moreover, deployment takes just months, so customers in
critical areas can enjoy improved power availability without waiting
years for it.
3
Re-energise your grid faster with self-healing capability
4
Self-healing is an innovative solution that improves re-energisation
time and availability in underground distribution networks. In the
event of a fault, it independently isolates faults and swiftly restores
service to fault-unaffected areas of the grid.
The solution is based on an off-the-shelf product, the Schneider
Electric Easergy T200 substation control unit. Once installed at the
main MV substations in the loop, Easergy T200 units establish peer-
to-peer communication over an IP network.
The entire system is decentralised, designed to function without
DMS or to complement it. The control centre is notified of a fault,
but there’s no waiting for an operator response. Instead, the
Easergy T200 units communicate automatically to find the fault,
isolate it, and re-energise the unaffected areas of the grid.
What’s more, this is a complete, fully supported solution. Schneider
Electric is there every step of the way, from concepting and design
to implementation and training.
Benefits
Fault isolation and service restoration in under 30 seconds,
reducing SAIDI
Quick design and simple implementation
Simple roll-out, with no DMS required
Cost-effective modernisation using an off-the-shelf product
Flexibility and ease-of-configuration via decentralisation
Ease of scalability and replicability
Greater savings, as data gathered by the Easergy T200 can be
used to maximise infrastructure efficiency
Automatically restore power after a fault
Primary substation
Substations upstream
and downstream from fault
5
51 2
3
Normal open point
4
When a fault occurs, the circuit breaker in the primary
substation trips and the rest of the feeder up until the
normal open point is de-energised.
The primary substation’s Easergy T200 unit communicates
with its immediate neighbour and so on along the feeder
until the fault is located.
When the fault area is localised, switches in the
substations immediately upstream and downstream
from the faulty section are opened to isolate the fault.
The normal open point is closed to restore supply
downstream from the faulty section.
The primary substation circuit breaker is closed again to
restore supply upstream from the faulty section.
Here’s how it works:
1
2
3
4
5
The self-healing grid solution is designed for underground networks
featuring open-loop architectures. By employing simple peer-to-peer
communication and step-by-step reconfiguration, it isolates the
faulted area, automatically restoring power to unaffected customers
in under 30 seconds. This translates to higher power availability in
critical areas, a lower SAIDI value, and greater customer satisfaction.
The result is the automatic restoration of power to
the unaffected area of the network within 30 seconds
of an outage.
6
Self-healing network scheme covering three feeders
Communication network
peer-to-peer communication (GPRS or ethernet)
HV/MV
HV/MV
substation
Normal
open point
Normal
open point
MV/LV
substation
HV/MV
MV/LV MV/LV MV/LV
MV/LV
MV/LV
MV/LV MV/LV
Key solution components
The Easergy T200 control unit
is designed for use in MV
substations. This off-the-shelf
product has a number of vital
functions, allowing remote control,
high-performance fault current
detection, and measurements for
better control of network load. The
Easergy T200 is also the heart of
the self-healing solution, enabling
decentralised monitoring and
control of substations.
Easy to install and cost-efficient
Compatible with any
SCADA system
Compatible with current and
legacy Schneider Electric
switchgear as well as
third-party equipment
Rugged and reliable design
tested for use in harsh conditions
Includes back-up power supply
for motorisation, transmission
equipment, and the control unit
Easergy T200 control unit
VPIS voltage indicator
VD23 voltage detection relay
Optimal switchgear for self-healing solution
A variety of Schneider Electric gas-
insulated ring main units are ideally
suited to the self-healing solution,
including FBX, Ringmaster, and RM6.
These switchgear are highly reliable,
designed for underground secondary
distribution applications, and have
a wide installed base. For an even
greater level of integration, the RM6 is
available with an embedded T200 unit.
Compact and highly efficient, the
VD23 perfectly complements a self-
healing grid, providing reliable data
regarding voltage presence.
The VPIS has a robust design and
exceeds the standards set by
IEC 62271-206. It works in tandem
with the VD23 to increase network
safety and reliability.
7
Schneider Electric Industries SAS
Head Office
35, rue Joseph Monier
CS 30323
92506 Rueil-Malmaison Cedex
France
www.schneider-electric.com
03-2013
Discover more about Schneider Electric self-healing solutions
and see how the system works for yourself!
Visit www.schneider-electric.com/selfhealing today!
©2013 Schneider Electric. All Rights Reserved. All other trademarks are property of their respective owners.
998-1189134_GMA-GB
Time-related performance capability
Maximum time to re-energise fault-unaffected area Typically 20 seconds. Maximum 30 seconds (depending on communications and number of nodes)
Performance capability
Number of controlled MV/LV substations per loop < 30
Maximum number of feeding points in a meshed network 3
Overloaded circuit prevention helps avoid damage to lines, cables, switchgear, and other hardware
Communications
Communication to SCADA IEC 870-5-104, DNP3 over IP, Modbus TCP
Peer-to-peer communication Modbus TCP
Media Ethernet, GSM/GPRS, 3G
Backup battery supply
AC supply 230 Vac - 50 Hz, (90 V to 270 Vac, with optional 43 V and 57 V).
Battery backup Up to 16 h + 10 open/close (O/F) cycles
Battery monitoring Total discharge, periodic tests, end of life
Fault passage indication and measurement
Phase-fault detection
Earth-fault detection
Ammeter, Maximeter
U, I, P, Q, S measurement, energy and power factor, cos ϕ With Modbus slave device (F200C, PM)
Voltage presence With additional VD23 or Flair 23DM unit

Weitere ähnliche Inhalte

Was ist angesagt?

[Case study] Jacksonville Electric Authority: Implementing a complete enterpr...
[Case study] Jacksonville Electric Authority: Implementing a complete enterpr...[Case study] Jacksonville Electric Authority: Implementing a complete enterpr...
[Case study] Jacksonville Electric Authority: Implementing a complete enterpr...Schneider Electric
 
[Case study] Green Mountain Power: Reducing the duration of outages
[Case study] Green Mountain Power: Reducing the duration of outages[Case study] Green Mountain Power: Reducing the duration of outages
[Case study] Green Mountain Power: Reducing the duration of outagesSchneider Electric
 
Distributech 2015 - Mobile Work management
Distributech 2015 - Mobile Work managementDistributech 2015 - Mobile Work management
Distributech 2015 - Mobile Work managementSchneider Electric
 
Advantages of a modern DCS in coal handling
Advantages of a modern DCS in coal handlingAdvantages of a modern DCS in coal handling
Advantages of a modern DCS in coal handlingSchneider Electric
 
A New Language for Specifying Modular Data Centers
A New Language for Specifying Modular Data CentersA New Language for Specifying Modular Data Centers
A New Language for Specifying Modular Data CentersSchneider Electric
 
[Webinar Slides] Advanced distribution management system integration of renew...
[Webinar Slides] Advanced distribution management system integration of renew...[Webinar Slides] Advanced distribution management system integration of renew...
[Webinar Slides] Advanced distribution management system integration of renew...Schneider Electric
 
Implementing energy efficient data centers
Implementing energy efficient  data centersImplementing energy efficient  data centers
Implementing energy efficient data centersSchneider Electric India
 
Four practical steps for reducing overall energy costs
Four practical steps for reducing overall energy costsFour practical steps for reducing overall energy costs
Four practical steps for reducing overall energy costsSchneider Electric India
 
[Case study] Eugene Water & Electric Board: Bringing together disparate legac...
[Case study] Eugene Water & Electric Board: Bringing together disparate legac...[Case study] Eugene Water & Electric Board: Bringing together disparate legac...
[Case study] Eugene Water & Electric Board: Bringing together disparate legac...Schneider Electric
 
ARC White paper: Schneider Electric Introduces First ePAC, Combines PAC with...
ARC White paper:  Schneider Electric Introduces First ePAC, Combines PAC with...ARC White paper:  Schneider Electric Introduces First ePAC, Combines PAC with...
ARC White paper: Schneider Electric Introduces First ePAC, Combines PAC with...Schneider Electric
 
Bringing Sustainable Efficiency to Wind Power
Bringing Sustainable Efficiency to Wind PowerBringing Sustainable Efficiency to Wind Power
Bringing Sustainable Efficiency to Wind PowerSchneider Electric
 
Microgrid & renewable integration at burbank water & power
Microgrid & renewable integration at burbank water & powerMicrogrid & renewable integration at burbank water & power
Microgrid & renewable integration at burbank water & powerSchneider Electric
 
[Case study] Kissimmee Utility Authority: Best compilation of products from o...
[Case study] Kissimmee Utility Authority: Best compilation of products from o...[Case study] Kissimmee Utility Authority: Best compilation of products from o...
[Case study] Kissimmee Utility Authority: Best compilation of products from o...Schneider Electric
 
Dtech 2015 the distribution management system network model
Dtech 2015  the distribution management system network modelDtech 2015  the distribution management system network model
Dtech 2015 the distribution management system network modelSchneider Electric
 
Making the grid more efficient, flexible and secure
Making the grid more efficient, flexible and secureMaking the grid more efficient, flexible and secure
Making the grid more efficient, flexible and secureSchneider Electric
 
An improved architecture for high efficiency, high-density data centers
An improved architecture for high efficiency, high-density data centersAn improved architecture for high efficiency, high-density data centers
An improved architecture for high efficiency, high-density data centersSchneider Electric India
 
Schneider Electric Renewable Energies Catalog
Schneider Electric Renewable Energies CatalogSchneider Electric Renewable Energies Catalog
Schneider Electric Renewable Energies CatalogSchneider Electric India
 
Asset Management - what are some of your top priorties?
Asset Management - what are some of your top priorties?Asset Management - what are some of your top priorties?
Asset Management - what are some of your top priorties?Schneider Electric
 
Water solution delivers an affordable upgrade and future-proof control
Water solution delivers an affordable upgrade and future-proof controlWater solution delivers an affordable upgrade and future-proof control
Water solution delivers an affordable upgrade and future-proof controlSchneider Electric
 
[Case study] Intermountain Rural Electric Association: Improving the quality ...
[Case study] Intermountain Rural Electric Association: Improving the quality ...[Case study] Intermountain Rural Electric Association: Improving the quality ...
[Case study] Intermountain Rural Electric Association: Improving the quality ...Schneider Electric
 

Was ist angesagt? (20)

[Case study] Jacksonville Electric Authority: Implementing a complete enterpr...
[Case study] Jacksonville Electric Authority: Implementing a complete enterpr...[Case study] Jacksonville Electric Authority: Implementing a complete enterpr...
[Case study] Jacksonville Electric Authority: Implementing a complete enterpr...
 
[Case study] Green Mountain Power: Reducing the duration of outages
[Case study] Green Mountain Power: Reducing the duration of outages[Case study] Green Mountain Power: Reducing the duration of outages
[Case study] Green Mountain Power: Reducing the duration of outages
 
Distributech 2015 - Mobile Work management
Distributech 2015 - Mobile Work managementDistributech 2015 - Mobile Work management
Distributech 2015 - Mobile Work management
 
Advantages of a modern DCS in coal handling
Advantages of a modern DCS in coal handlingAdvantages of a modern DCS in coal handling
Advantages of a modern DCS in coal handling
 
A New Language for Specifying Modular Data Centers
A New Language for Specifying Modular Data CentersA New Language for Specifying Modular Data Centers
A New Language for Specifying Modular Data Centers
 
[Webinar Slides] Advanced distribution management system integration of renew...
[Webinar Slides] Advanced distribution management system integration of renew...[Webinar Slides] Advanced distribution management system integration of renew...
[Webinar Slides] Advanced distribution management system integration of renew...
 
Implementing energy efficient data centers
Implementing energy efficient  data centersImplementing energy efficient  data centers
Implementing energy efficient data centers
 
Four practical steps for reducing overall energy costs
Four practical steps for reducing overall energy costsFour practical steps for reducing overall energy costs
Four practical steps for reducing overall energy costs
 
[Case study] Eugene Water & Electric Board: Bringing together disparate legac...
[Case study] Eugene Water & Electric Board: Bringing together disparate legac...[Case study] Eugene Water & Electric Board: Bringing together disparate legac...
[Case study] Eugene Water & Electric Board: Bringing together disparate legac...
 
ARC White paper: Schneider Electric Introduces First ePAC, Combines PAC with...
ARC White paper:  Schneider Electric Introduces First ePAC, Combines PAC with...ARC White paper:  Schneider Electric Introduces First ePAC, Combines PAC with...
ARC White paper: Schneider Electric Introduces First ePAC, Combines PAC with...
 
Bringing Sustainable Efficiency to Wind Power
Bringing Sustainable Efficiency to Wind PowerBringing Sustainable Efficiency to Wind Power
Bringing Sustainable Efficiency to Wind Power
 
Microgrid & renewable integration at burbank water & power
Microgrid & renewable integration at burbank water & powerMicrogrid & renewable integration at burbank water & power
Microgrid & renewable integration at burbank water & power
 
[Case study] Kissimmee Utility Authority: Best compilation of products from o...
[Case study] Kissimmee Utility Authority: Best compilation of products from o...[Case study] Kissimmee Utility Authority: Best compilation of products from o...
[Case study] Kissimmee Utility Authority: Best compilation of products from o...
 
Dtech 2015 the distribution management system network model
Dtech 2015  the distribution management system network modelDtech 2015  the distribution management system network model
Dtech 2015 the distribution management system network model
 
Making the grid more efficient, flexible and secure
Making the grid more efficient, flexible and secureMaking the grid more efficient, flexible and secure
Making the grid more efficient, flexible and secure
 
An improved architecture for high efficiency, high-density data centers
An improved architecture for high efficiency, high-density data centersAn improved architecture for high efficiency, high-density data centers
An improved architecture for high efficiency, high-density data centers
 
Schneider Electric Renewable Energies Catalog
Schneider Electric Renewable Energies CatalogSchneider Electric Renewable Energies Catalog
Schneider Electric Renewable Energies Catalog
 
Asset Management - what are some of your top priorties?
Asset Management - what are some of your top priorties?Asset Management - what are some of your top priorties?
Asset Management - what are some of your top priorties?
 
Water solution delivers an affordable upgrade and future-proof control
Water solution delivers an affordable upgrade and future-proof controlWater solution delivers an affordable upgrade and future-proof control
Water solution delivers an affordable upgrade and future-proof control
 
[Case study] Intermountain Rural Electric Association: Improving the quality ...
[Case study] Intermountain Rural Electric Association: Improving the quality ...[Case study] Intermountain Rural Electric Association: Improving the quality ...
[Case study] Intermountain Rural Electric Association: Improving the quality ...
 

Ähnlich wie Underground Self-Healing Solution

Presentacion_Gestion_De_La_Energia_2023_2024_2050
Presentacion_Gestion_De_La_Energia_2023_2024_2050Presentacion_Gestion_De_La_Energia_2023_2024_2050
Presentacion_Gestion_De_La_Energia_2023_2024_2050FernandodelaCruz87
 
ADMS (Advanced Distribution Management System)
ADMS (Advanced Distribution Management System)ADMS (Advanced Distribution Management System)
ADMS (Advanced Distribution Management System)Schneider Electric
 
Riello multi-power-modular-ups-datasheet
Riello multi-power-modular-ups-datasheetRiello multi-power-modular-ups-datasheet
Riello multi-power-modular-ups-datasheetRobin Koffler MBA CDCEP
 
Wired-wireless or both - Presented by Ross Eberlin
Wired-wireless or both - Presented by Ross EberlinWired-wireless or both - Presented by Ross Eberlin
Wired-wireless or both - Presented by Ross EberlinCindy Foster-Warthen
 
SICAM FSI – Fault Sensor Indicator
SICAM FSI – Fault Sensor IndicatorSICAM FSI – Fault Sensor Indicator
SICAM FSI – Fault Sensor Indicatorashwini reliserv
 
Introduction of 132/11 kV Digitally Optimized Substation for Protection, Cont...
Introduction of 132/11 kV Digitally Optimized Substation for Protection, Cont...Introduction of 132/11 kV Digitally Optimized Substation for Protection, Cont...
Introduction of 132/11 kV Digitally Optimized Substation for Protection, Cont...IRJET Journal
 
EasergyT300_Catalog_NRJED314621EN_022018.pdf
EasergyT300_Catalog_NRJED314621EN_022018.pdfEasergyT300_Catalog_NRJED314621EN_022018.pdf
EasergyT300_Catalog_NRJED314621EN_022018.pdfShantieHarunAlRosyid
 
Ahola_ASelfhealingPowerSystem_757736_ENa.ppt
Ahola_ASelfhealingPowerSystem_757736_ENa.pptAhola_ASelfhealingPowerSystem_757736_ENa.ppt
Ahola_ASelfhealingPowerSystem_757736_ENa.pptCarloViggiano3
 
POWER CONSUMPTION DETECTING AND ALERTING SYSTEM
POWER CONSUMPTION DETECTING AND ALERTING SYSTEMPOWER CONSUMPTION DETECTING AND ALERTING SYSTEM
POWER CONSUMPTION DETECTING AND ALERTING SYSTEMIRJET Journal
 
Redwood_Solution_Brochure
Redwood_Solution_BrochureRedwood_Solution_Brochure
Redwood_Solution_BrochureTim Gu
 
TRANSFORMER HEALTH MONITORING SYSTEM
TRANSFORMER HEALTH MONITORING SYSTEMTRANSFORMER HEALTH MONITORING SYSTEM
TRANSFORMER HEALTH MONITORING SYSTEMIRJET Journal
 
FEEDER PROTECTION SYSTEM FROM EARTH FAULT, SHORT CIRCUIT AND OVERLOAD FAULTS
FEEDER PROTECTION SYSTEM FROM EARTH FAULT, SHORT CIRCUIT AND OVERLOAD FAULTSFEEDER PROTECTION SYSTEM FROM EARTH FAULT, SHORT CIRCUIT AND OVERLOAD FAULTS
FEEDER PROTECTION SYSTEM FROM EARTH FAULT, SHORT CIRCUIT AND OVERLOAD FAULTSIRJET Journal
 
Smarter Grid Solutions Company Overview
Smarter Grid Solutions Company OverviewSmarter Grid Solutions Company Overview
Smarter Grid Solutions Company OverviewSmarter Grid Solutions
 
teltonika-networks-use-case-catalog-v1.2.pdf
teltonika-networks-use-case-catalog-v1.2.pdfteltonika-networks-use-case-catalog-v1.2.pdf
teltonika-networks-use-case-catalog-v1.2.pdfitsamihaland
 
Dienhathe.com e86060-t1871-a101-a1-7600
Dienhathe.com e86060-t1871-a101-a1-7600Dienhathe.com e86060-t1871-a101-a1-7600
Dienhathe.com e86060-t1871-a101-a1-7600Dien Ha The
 

Ähnlich wie Underground Self-Healing Solution (20)

Presentacion_Gestion_De_La_Energia_2023_2024_2050
Presentacion_Gestion_De_La_Energia_2023_2024_2050Presentacion_Gestion_De_La_Energia_2023_2024_2050
Presentacion_Gestion_De_La_Energia_2023_2024_2050
 
Small hydro solutions
Small hydro solutionsSmall hydro solutions
Small hydro solutions
 
ADMS (Advanced Distribution Management System)
ADMS (Advanced Distribution Management System)ADMS (Advanced Distribution Management System)
ADMS (Advanced Distribution Management System)
 
Riello multi-power-modular-ups-datasheet
Riello multi-power-modular-ups-datasheetRiello multi-power-modular-ups-datasheet
Riello multi-power-modular-ups-datasheet
 
Wired-wireless or both - Presented by Ross Eberlin
Wired-wireless or both - Presented by Ross EberlinWired-wireless or both - Presented by Ross Eberlin
Wired-wireless or both - Presented by Ross Eberlin
 
SICAM FSI – Fault Sensor Indicator
SICAM FSI – Fault Sensor IndicatorSICAM FSI – Fault Sensor Indicator
SICAM FSI – Fault Sensor Indicator
 
Introduction of 132/11 kV Digitally Optimized Substation for Protection, Cont...
Introduction of 132/11 kV Digitally Optimized Substation for Protection, Cont...Introduction of 132/11 kV Digitally Optimized Substation for Protection, Cont...
Introduction of 132/11 kV Digitally Optimized Substation for Protection, Cont...
 
EasergyT300_Catalog_NRJED314621EN_022018.pdf
EasergyT300_Catalog_NRJED314621EN_022018.pdfEasergyT300_Catalog_NRJED314621EN_022018.pdf
EasergyT300_Catalog_NRJED314621EN_022018.pdf
 
MS5000 Snapshot
MS5000 SnapshotMS5000 Snapshot
MS5000 Snapshot
 
MIDAS Folder
MIDAS FolderMIDAS Folder
MIDAS Folder
 
Ahola_ASelfhealingPowerSystem_757736_ENa.ppt
Ahola_ASelfhealingPowerSystem_757736_ENa.pptAhola_ASelfhealingPowerSystem_757736_ENa.ppt
Ahola_ASelfhealingPowerSystem_757736_ENa.ppt
 
POWER CONSUMPTION DETECTING AND ALERTING SYSTEM
POWER CONSUMPTION DETECTING AND ALERTING SYSTEMPOWER CONSUMPTION DETECTING AND ALERTING SYSTEM
POWER CONSUMPTION DETECTING AND ALERTING SYSTEM
 
Redwood_Solution_Brochure
Redwood_Solution_BrochureRedwood_Solution_Brochure
Redwood_Solution_Brochure
 
TRANSFORMER HEALTH MONITORING SYSTEM
TRANSFORMER HEALTH MONITORING SYSTEMTRANSFORMER HEALTH MONITORING SYSTEM
TRANSFORMER HEALTH MONITORING SYSTEM
 
Catalog busbar Legrand
Catalog busbar LegrandCatalog busbar Legrand
Catalog busbar Legrand
 
Products & services (new)
Products & services (new)Products & services (new)
Products & services (new)
 
FEEDER PROTECTION SYSTEM FROM EARTH FAULT, SHORT CIRCUIT AND OVERLOAD FAULTS
FEEDER PROTECTION SYSTEM FROM EARTH FAULT, SHORT CIRCUIT AND OVERLOAD FAULTSFEEDER PROTECTION SYSTEM FROM EARTH FAULT, SHORT CIRCUIT AND OVERLOAD FAULTS
FEEDER PROTECTION SYSTEM FROM EARTH FAULT, SHORT CIRCUIT AND OVERLOAD FAULTS
 
Smarter Grid Solutions Company Overview
Smarter Grid Solutions Company OverviewSmarter Grid Solutions Company Overview
Smarter Grid Solutions Company Overview
 
teltonika-networks-use-case-catalog-v1.2.pdf
teltonika-networks-use-case-catalog-v1.2.pdfteltonika-networks-use-case-catalog-v1.2.pdf
teltonika-networks-use-case-catalog-v1.2.pdf
 
Dienhathe.com e86060-t1871-a101-a1-7600
Dienhathe.com e86060-t1871-a101-a1-7600Dienhathe.com e86060-t1871-a101-a1-7600
Dienhathe.com e86060-t1871-a101-a1-7600
 

Mehr von Schneider Electric

Secure Power Design Considerations
Secure Power Design ConsiderationsSecure Power Design Considerations
Secure Power Design ConsiderationsSchneider Electric
 
Digital International Colo Club: Attracting Investors
Digital International Colo Club: Attracting InvestorsDigital International Colo Club: Attracting Investors
Digital International Colo Club: Attracting InvestorsSchneider Electric
 
32 phaseo power supplies and transformers briefing
32 phaseo power supplies and transformers briefing 32 phaseo power supplies and transformers briefing
32 phaseo power supplies and transformers briefing Schneider Electric
 
Key Industry Trends, M&A Valuation Trends
Key Industry Trends, M&A Valuation TrendsKey Industry Trends, M&A Valuation Trends
Key Industry Trends, M&A Valuation TrendsSchneider Electric
 
EcoStruxure™ for Cloud & Service Providers
 EcoStruxure™ for Cloud & Service Providers EcoStruxure™ for Cloud & Service Providers
EcoStruxure™ for Cloud & Service ProvidersSchneider Electric
 
Zelio Time Electronic Relay Briefing
Zelio Time Electronic Relay BriefingZelio Time Electronic Relay Briefing
Zelio Time Electronic Relay BriefingSchneider Electric
 
Spacial, Thalassa, ClimaSys Universal enclosures Briefing
Spacial, Thalassa, ClimaSys Universal enclosures BriefingSpacial, Thalassa, ClimaSys Universal enclosures Briefing
Spacial, Thalassa, ClimaSys Universal enclosures BriefingSchneider Electric
 
Relay Control Zelio SSR Briefing
Relay Control Zelio SSR BriefingRelay Control Zelio SSR Briefing
Relay Control Zelio SSR BriefingSchneider Electric
 
Magelis HMI, iPC and software Briefing
Magelis HMI, iPC and software BriefingMagelis HMI, iPC and software Briefing
Magelis HMI, iPC and software BriefingSchneider Electric
 
Where will the next 80% improvement in data center performance come from?
Where will the next 80% improvement in data center performance come from?Where will the next 80% improvement in data center performance come from?
Where will the next 80% improvement in data center performance come from?Schneider Electric
 
EcoStruxure for Intuitive Industries
EcoStruxure for Intuitive IndustriesEcoStruxure for Intuitive Industries
EcoStruxure for Intuitive IndustriesSchneider Electric
 
Systems Integrator Alliance Program 2017
Systems Integrator Alliance Program 2017Systems Integrator Alliance Program 2017
Systems Integrator Alliance Program 2017Schneider Electric
 
EcoStruxure, IIoT-enabled architecture, delivering value in key segments.
EcoStruxure, IIoT-enabled architecture, delivering value in key segments.EcoStruxure, IIoT-enabled architecture, delivering value in key segments.
EcoStruxure, IIoT-enabled architecture, delivering value in key segments.Schneider Electric
 
It's time to modernize your industrial controls with Modicon M580
It's time to modernize your industrial controls with Modicon M580It's time to modernize your industrial controls with Modicon M580
It's time to modernize your industrial controls with Modicon M580Schneider Electric
 
A Practical Guide to Ensuring Business Continuity and High Performance in Hea...
A Practical Guide to Ensuring Business Continuity and High Performance in Hea...A Practical Guide to Ensuring Business Continuity and High Performance in Hea...
A Practical Guide to Ensuring Business Continuity and High Performance in Hea...Schneider Electric
 
Connected Services Study – Facility Managers Respond to IoT
Connected Services Study – Facility Managers Respond to IoTConnected Services Study – Facility Managers Respond to IoT
Connected Services Study – Facility Managers Respond to IoTSchneider Electric
 
Telemecanqiue Cabling and Accessories Briefing
Telemecanqiue Cabling and Accessories BriefingTelemecanqiue Cabling and Accessories Briefing
Telemecanqiue Cabling and Accessories BriefingSchneider Electric
 
Telemecanique Photoelectric Sensors Briefing
Telemecanique Photoelectric Sensors BriefingTelemecanique Photoelectric Sensors Briefing
Telemecanique Photoelectric Sensors BriefingSchneider Electric
 
Telemecanique Limit Switches Briefing
Telemecanique Limit Switches BriefingTelemecanique Limit Switches Briefing
Telemecanique Limit Switches BriefingSchneider Electric
 

Mehr von Schneider Electric (20)

Secure Power Design Considerations
Secure Power Design ConsiderationsSecure Power Design Considerations
Secure Power Design Considerations
 
Digital International Colo Club: Attracting Investors
Digital International Colo Club: Attracting InvestorsDigital International Colo Club: Attracting Investors
Digital International Colo Club: Attracting Investors
 
32 phaseo power supplies and transformers briefing
32 phaseo power supplies and transformers briefing 32 phaseo power supplies and transformers briefing
32 phaseo power supplies and transformers briefing
 
Key Industry Trends, M&A Valuation Trends
Key Industry Trends, M&A Valuation TrendsKey Industry Trends, M&A Valuation Trends
Key Industry Trends, M&A Valuation Trends
 
EcoStruxure™ for Cloud & Service Providers
 EcoStruxure™ for Cloud & Service Providers EcoStruxure™ for Cloud & Service Providers
EcoStruxure™ for Cloud & Service Providers
 
Magelis Basic HMI Briefing
Magelis Basic HMI Briefing Magelis Basic HMI Briefing
Magelis Basic HMI Briefing
 
Zelio Time Electronic Relay Briefing
Zelio Time Electronic Relay BriefingZelio Time Electronic Relay Briefing
Zelio Time Electronic Relay Briefing
 
Spacial, Thalassa, ClimaSys Universal enclosures Briefing
Spacial, Thalassa, ClimaSys Universal enclosures BriefingSpacial, Thalassa, ClimaSys Universal enclosures Briefing
Spacial, Thalassa, ClimaSys Universal enclosures Briefing
 
Relay Control Zelio SSR Briefing
Relay Control Zelio SSR BriefingRelay Control Zelio SSR Briefing
Relay Control Zelio SSR Briefing
 
Magelis HMI, iPC and software Briefing
Magelis HMI, iPC and software BriefingMagelis HMI, iPC and software Briefing
Magelis HMI, iPC and software Briefing
 
Where will the next 80% improvement in data center performance come from?
Where will the next 80% improvement in data center performance come from?Where will the next 80% improvement in data center performance come from?
Where will the next 80% improvement in data center performance come from?
 
EcoStruxure for Intuitive Industries
EcoStruxure for Intuitive IndustriesEcoStruxure for Intuitive Industries
EcoStruxure for Intuitive Industries
 
Systems Integrator Alliance Program 2017
Systems Integrator Alliance Program 2017Systems Integrator Alliance Program 2017
Systems Integrator Alliance Program 2017
 
EcoStruxure, IIoT-enabled architecture, delivering value in key segments.
EcoStruxure, IIoT-enabled architecture, delivering value in key segments.EcoStruxure, IIoT-enabled architecture, delivering value in key segments.
EcoStruxure, IIoT-enabled architecture, delivering value in key segments.
 
It's time to modernize your industrial controls with Modicon M580
It's time to modernize your industrial controls with Modicon M580It's time to modernize your industrial controls with Modicon M580
It's time to modernize your industrial controls with Modicon M580
 
A Practical Guide to Ensuring Business Continuity and High Performance in Hea...
A Practical Guide to Ensuring Business Continuity and High Performance in Hea...A Practical Guide to Ensuring Business Continuity and High Performance in Hea...
A Practical Guide to Ensuring Business Continuity and High Performance in Hea...
 
Connected Services Study – Facility Managers Respond to IoT
Connected Services Study – Facility Managers Respond to IoTConnected Services Study – Facility Managers Respond to IoT
Connected Services Study – Facility Managers Respond to IoT
 
Telemecanqiue Cabling and Accessories Briefing
Telemecanqiue Cabling and Accessories BriefingTelemecanqiue Cabling and Accessories Briefing
Telemecanqiue Cabling and Accessories Briefing
 
Telemecanique Photoelectric Sensors Briefing
Telemecanique Photoelectric Sensors BriefingTelemecanique Photoelectric Sensors Briefing
Telemecanique Photoelectric Sensors Briefing
 
Telemecanique Limit Switches Briefing
Telemecanique Limit Switches BriefingTelemecanique Limit Switches Briefing
Telemecanique Limit Switches Briefing
 

Kürzlich hochgeladen

Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationRadu Cotescu
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityPrincipled Technologies
 
The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024Rafal Los
 
[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdfhans926745
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Drew Madelung
 
Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024The Digital Insurer
 
Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Enterprise Knowledge
 
Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024The Digital Insurer
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonAnna Loughnan Colquhoun
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...apidays
 
Advantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your BusinessAdvantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your BusinessPixlogix Infotech
 
The Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxThe Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxMalak Abu Hammad
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerThousandEyes
 
Boost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfBoost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfsudhanshuwaghmare1
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsMaria Levchenko
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024The Digital Insurer
 
🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘RTylerCroy
 
Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)wesley chun
 
Automating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps ScriptAutomating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps Scriptwesley chun
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonetsnaman860154
 

Kürzlich hochgeladen (20)

Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organization
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivity
 
The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024
 
[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
 
Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024
 
Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...
 
Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt Robison
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
 
Advantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your BusinessAdvantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your Business
 
The Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxThe Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptx
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected Worker
 
Boost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfBoost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdf
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed texts
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
 
🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘
 
Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)
 
Automating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps ScriptAutomating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps Script
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonets
 

Underground Self-Healing Solution

  • 1. Reduce re-energisation time for your electricity customers Introducing a cost-effective self-healing solution for underground open-loop networks
  • 2. Under 30 seconds That’s how fast our underground self-healing solution restores power to healthy areas of a distribution network
  • 3. A simpler way to boost grid availability and reliability Operating an electrical distribution grid is an increasingly complex business. The challenges posed by growing demand, integration of distributed generation resources, and ageing infrastructure – to name just a few – all have an effect on overall grid reliability, and on customer satisfaction. Grid operators need to face these challenges in order to boost efficiency, protect their customers and avoid regulatory scrutiny, but it’s not easy. Most solutions that reduce the frequency and duration of power outages also require large capital expenditures, complicated installation of new equipment, and can take years to implement. There is another option, though – a self-healing network solution from Schneider Electric. This is a smart, cost-effective way to enhance the reliability of underground electrical distribution grids. Moreover, deployment takes just months, so customers in critical areas can enjoy improved power availability without waiting years for it. 3
  • 4. Re-energise your grid faster with self-healing capability 4 Self-healing is an innovative solution that improves re-energisation time and availability in underground distribution networks. In the event of a fault, it independently isolates faults and swiftly restores service to fault-unaffected areas of the grid. The solution is based on an off-the-shelf product, the Schneider Electric Easergy T200 substation control unit. Once installed at the main MV substations in the loop, Easergy T200 units establish peer- to-peer communication over an IP network. The entire system is decentralised, designed to function without DMS or to complement it. The control centre is notified of a fault, but there’s no waiting for an operator response. Instead, the Easergy T200 units communicate automatically to find the fault, isolate it, and re-energise the unaffected areas of the grid. What’s more, this is a complete, fully supported solution. Schneider Electric is there every step of the way, from concepting and design to implementation and training. Benefits Fault isolation and service restoration in under 30 seconds, reducing SAIDI Quick design and simple implementation Simple roll-out, with no DMS required Cost-effective modernisation using an off-the-shelf product Flexibility and ease-of-configuration via decentralisation Ease of scalability and replicability Greater savings, as data gathered by the Easergy T200 can be used to maximise infrastructure efficiency
  • 5. Automatically restore power after a fault Primary substation Substations upstream and downstream from fault 5 51 2 3 Normal open point 4 When a fault occurs, the circuit breaker in the primary substation trips and the rest of the feeder up until the normal open point is de-energised. The primary substation’s Easergy T200 unit communicates with its immediate neighbour and so on along the feeder until the fault is located. When the fault area is localised, switches in the substations immediately upstream and downstream from the faulty section are opened to isolate the fault. The normal open point is closed to restore supply downstream from the faulty section. The primary substation circuit breaker is closed again to restore supply upstream from the faulty section. Here’s how it works: 1 2 3 4 5 The self-healing grid solution is designed for underground networks featuring open-loop architectures. By employing simple peer-to-peer communication and step-by-step reconfiguration, it isolates the faulted area, automatically restoring power to unaffected customers in under 30 seconds. This translates to higher power availability in critical areas, a lower SAIDI value, and greater customer satisfaction. The result is the automatic restoration of power to the unaffected area of the network within 30 seconds of an outage.
  • 6. 6 Self-healing network scheme covering three feeders Communication network peer-to-peer communication (GPRS or ethernet) HV/MV HV/MV substation Normal open point Normal open point MV/LV substation HV/MV MV/LV MV/LV MV/LV MV/LV MV/LV MV/LV MV/LV
  • 7. Key solution components The Easergy T200 control unit is designed for use in MV substations. This off-the-shelf product has a number of vital functions, allowing remote control, high-performance fault current detection, and measurements for better control of network load. The Easergy T200 is also the heart of the self-healing solution, enabling decentralised monitoring and control of substations. Easy to install and cost-efficient Compatible with any SCADA system Compatible with current and legacy Schneider Electric switchgear as well as third-party equipment Rugged and reliable design tested for use in harsh conditions Includes back-up power supply for motorisation, transmission equipment, and the control unit Easergy T200 control unit VPIS voltage indicator VD23 voltage detection relay Optimal switchgear for self-healing solution A variety of Schneider Electric gas- insulated ring main units are ideally suited to the self-healing solution, including FBX, Ringmaster, and RM6. These switchgear are highly reliable, designed for underground secondary distribution applications, and have a wide installed base. For an even greater level of integration, the RM6 is available with an embedded T200 unit. Compact and highly efficient, the VD23 perfectly complements a self- healing grid, providing reliable data regarding voltage presence. The VPIS has a robust design and exceeds the standards set by IEC 62271-206. It works in tandem with the VD23 to increase network safety and reliability. 7
  • 8. Schneider Electric Industries SAS Head Office 35, rue Joseph Monier CS 30323 92506 Rueil-Malmaison Cedex France www.schneider-electric.com 03-2013 Discover more about Schneider Electric self-healing solutions and see how the system works for yourself! Visit www.schneider-electric.com/selfhealing today! ©2013 Schneider Electric. All Rights Reserved. All other trademarks are property of their respective owners. 998-1189134_GMA-GB Time-related performance capability Maximum time to re-energise fault-unaffected area Typically 20 seconds. Maximum 30 seconds (depending on communications and number of nodes) Performance capability Number of controlled MV/LV substations per loop < 30 Maximum number of feeding points in a meshed network 3 Overloaded circuit prevention helps avoid damage to lines, cables, switchgear, and other hardware Communications Communication to SCADA IEC 870-5-104, DNP3 over IP, Modbus TCP Peer-to-peer communication Modbus TCP Media Ethernet, GSM/GPRS, 3G Backup battery supply AC supply 230 Vac - 50 Hz, (90 V to 270 Vac, with optional 43 V and 57 V). Battery backup Up to 16 h + 10 open/close (O/F) cycles Battery monitoring Total discharge, periodic tests, end of life Fault passage indication and measurement Phase-fault detection Earth-fault detection Ammeter, Maximeter U, I, P, Q, S measurement, energy and power factor, cos ϕ With Modbus slave device (F200C, PM) Voltage presence With additional VD23 or Flair 23DM unit