SlideShare ist ein Scribd-Unternehmen logo
1 von 13
Downloaden Sie, um offline zu lesen
1
NEW HOT BITUMEN STORAGE TANK
CONSTRUCTION GUIDELINES
The information and recommendations in these guidelines are given in good faith and
belief in their accuracy at the time of publication, but does not imply any legal liability or
responsibility by the Refined Bitumen Association.
The Health and Safety at Work Act 1974 and the Management of Health and Safety
Regulations 1999 require employers to provide safe systems of work to ensure the
safety of their employees and the public. Health and Safety Law imposes duties on
both the supplier and the customer to provide safe systems of work. These guidelines
are intended to help both parties comply with their respective responsibilities during the
transfer, handling, and storing of hot bitumen at hot mix asphalt manufacturing plants,
and are not intended to vary the legal responsibility of either party.
PURPOSE
These guidelines provide hot mix asphalt manufacturing plant Owners/Operators
information to aid in designing, fabricating and erecting new hot bitumen storage tanks
at their facilities.
SCOPE
These guidelines are applicable for above-ground atmospheric-pressure hot bitumen
bitumen storage tanks that have a maximum design temperature of 260°C (500°F) .
The stored product is heated petroleum-derived bitumen products with Open Cup Flash
Points above 163°C (325°F), such as penetration grades, oxidised grades and polymer
modified bitumen. These guidelines are not applicable for other bitumen products with
lower Open Cup Flash Points, such as emulsions and cut-back bitumens.
Transferring, handling, and storing hot bitumen expose plant operators and hauliers to
inherent hazards:
‱ Thermal burns.
‱ Froth-overs and boil-overs due to contamination by water or lower boiling point
hydrocarbons.
‱ Formation and release of hydrogen sulphide.
‱ Formation and release of hydrocarbon fumes.
‱ Formation of flammable vapours.
‱ Creation of ignition sources - pyrophoric deposits, hot surfaces, sparks and open
flames.
‱ Falls from elevated work surfaces.
2
Due to these inherent hazards and the complexities involved with designing and
constructing hot bitumen storage tanks, Owners/Operators should consult and hire
suitably qualified engineering firms when initiating a new tank project. A qualified
engineering firm will be knowledgeable in the design/construction process of hot
bitumen storage tanks, including all applicable specifications, codes, and regulatory
requirements. A qualified engineering firm will develop a tank design that meets these
requirements and mitigates the risks of these inherent hazards.
These guidelines are general in nature, and intended to aid Owners/Operators in
discussions with design engineers, geotechnical engineers, site contractors, fabricators
and equipment suppliers contracted to design and construct hot bitumen storage tanks.
REFERENCES
API Recommended Practice 2023, "Guide for Safe Storage and Handling of Heated
Petroleum-Derived Asphalt Products and Crude-Oil Residua", August 2001.
API Standard 650, "Welded Tanks for Oil Storage", June 2007.
API Standard 2000, "Venting Atmospheric and Low-Pressure Storage Tanks", April
1998.
Asphalt Institute Manual Series No. 4 (MS-4), The Asphalt Handbook, 7th
edition, 2007.
Asphalt Institute Manual Series No. 22 (MS-22), Principles of Construction of Hot-Mix
Asphalt Pavements, 2nd
edition.
”Guide to Safe Delivery of Bitumen – UK Edition, Refined Bitumen Association.
"Guidance for Safe Bitumen Tank Management", Refined Bitumen Association / Mineral
Products Association.
"RBA Position Paper on the use of Ground-Based Pumps for Bitumen Discharge at
Customer Sites", Refined Bitumen Association.
Model code of safe practice, Part 11, Bitumen Safety Code (4th
edition), Energy
Institute.
Dangerous Substances and Explosive Atmospheres Regulations 2002.
BS EN 61511:2004 Functional Safety – Safety Instrumented Systems for the process
industry sector (Part 1 to 3).
3
DEFINITIONS
Bitumen Discharge Area: Area within the plant specifically designed to safely offload
and receive vehicle deliveries of hot bitumen. The bitumen is pumped from the bitumen
discharge area to the hot bitumen storage tank.
Boil-over: Fiery tank overflow caused by hot residue from a surface fire in a bitumen
tank becoming denser and sinking in the tank to form a hot layer that causes a violent
eruption of burning bitumen when the sinking hot layer comes in contact with a water or
lower boiling point hydrocarbon layer.
Froth-over: Tank overflow caused by hot bitumen being placed over a layer of water or
lower boiling point hydrocarbons, causing the water/hydrocarbons to boil and vaporise,
pass through the upper layer of bitumen and overflow the tank with hot bitumen.
Hot Bitumen: Heated petroleum-based bitumen products with Open Cup Flash Points
above 163°C (325°F), and typically stored in the range of 130° - 168°C (265° - 335°F).
Open Cup Flash Point: Minimum Cleveland Open Cup Flash temperature as
determined by AASHTO T48 and ASTM D 92.
Pyrophoric Deposits: Pyrophoric carbonaceous deposits are formed on the roof and
walls of bitumen storage tanks due to the condensation of bitumen vapors, which can
become a potential ignition source at temperatures between 177°- 190°C (350° - 375°F)
due to oxidation when exposed to an influx of air. Pyrophoric iron sulphide deposits are
formed due to hydrogen sulphide reacting with the iron in the tank's roof and walls in the
presence of moisture, which can also become a potential ignition source due to
oxidation when exposed to air.
Roof-to-Shell Frangible Joint: Roof-to-shell joint designed to selectively fail due to
abnormal internal tank pressure before other joints or connections fail catastrophically.
Ullage: Empty interior tank volume available for deliveries of bitumen.
4
GENERAL GUIDELINES
A. Site layout considerations
1. Traffic patterns for bitumen delivery vehicles, other vehicles, and personnel on
foot within the plant, to include optimising one-way traffic flows and minimising
reversing of vehicles.
2. Proximity of bitumen storage tank and bitumen discharge area to other plant
operations and traffic patterns of other vehicles The location of the discharge
point must avoid surrounding or adjacent operations which could impair safe
delivery.
3. Sufficient work space around the tank and equipment:
a) Sufficient area to meet future maintenance and testing requirements, such
as removing the heating device from the tank for inspection, maintenance,
and replacement.
b) Reduce the potential risk for trips and falls.
4. In addition to meeting spacing requirements, it may be advantageous to
minimise pipe runs between the proposed tank, bitumen discharge area, and
plant mixer, due to construction costs, future maintenance and energy costs
related to pipe heat tracing and insulation needs.
5. Vent / overflow pipework location – consider the potential exposure of personnel
and vehicles should hot bitumen, bitumen fumes, or hydrogen sulphide be
released to the atmosphere.
6. Lines of sight between plant personnel (plant control room) and haulier; haulier
and tank (vent); and plant personnel (plant control room) and tank.
7. Tank and equipment spill containment.
8. Elevation differential between bitumen discharge area and tank - if the head
pressure differential and line friction losses are too great for the delivery
vehicle's pump, a ground-based pump may be needed. An added benefit to the
installation of a ground-based pump may be the elimination of bitumen
deliveries via compressed air discharge systems and their associated hazards.
(See "RBA Position Paper on the use of Ground-Based Pumps for Bitumen
Discharge at Customer Sites", Refined Bitumen Association, Ltd for additional
guidance on ground-based pumps.)
5
9. Terrain contour of site:
a) Level working surfaces in key site locations, such as bitumen discharge
area, areas around the bitumen tank, pump areas and any work area with
an increased likelihood of trips and falls occurring.
b) Drainage patterns around key site locations, such as bitumen discharge
area; areas around tank, sampling port location, pump area and other
areas to minimise:
1) Potential water contact with hot bitumen.
2) Corrosion.
3) Moisture buildup in tank insulation.
4) Potential slips and falls.
c) Potential access to public sewers, waterways, or adjoining properties may
dictate the need for emergency drainage systems with traps or separators.
10. Emergency equipment and plans, such as locating emergency shower(s) and
eye wash stand(s), emergency shut-off switch(es), fire extinguishers, tank vent,
and alarm display(s) and horn(s); identifying evacuation route(s); and ensuring
required accessibility for fire fighting.
11. Lighting for key work areas.
B. Tank size design considerations (See "Guidance for Safe Bitumen Tank
Management" or the “Guide to Safe Delivery of Bitumen”, Refined Bitumen
Association, Ltd for additional information regarding tank dimensions and defined
capacities.)
1. Safe Working Tank Capacity (m3
) - Owner/Operator to determine how much
volume is needed in the tank to store bitumen that will be available for draw off
for use in plant manufacturing requirements. The intent is to prevent unplanned
run outs, and its capacity is usually determined based upon:
a) Bitumen hauling capacity of local delivery vehicles and the projected
bitumen availability from suppliers, to include potential delays during
periods of peak supply demand (rate in).
b) Peak production rate requirements at Owner/Operator's plant (rate out).
c) The maximum potential temperature differential, between the minimum
temperature of the delivered bitumen and the maximum bitumen storage
temperature, should be considered. (See Volumetric to Mass Conversion
Factor below in GENERAL GUIDELINES, paragraph B.6.)
6
2. Available Tank Capacity (m3
) - Design Engineer to calculate by applying a
safety factor to the Owner/Operator's desired Safe Working Tank Capacity
(safety factor should be endorsed by Owner/Operator). This safety factor is
established to allow sufficient time to safely shut down tank filling operations to
avoid overfilling the tank, and is based on maximum potential tank filling rates.
The Available Tank Capacity comprises the internal volume from the draw off
nozzle to the tank vent / overfill pipework.
3. Unavailable Tank Capacity (m3
) - Determined by the Design Engineer and
consisting of both the
a) Internal volume from the floor of the tank to the normal draw-off nozzle
(undrawable or heel capacity). This is where the tank's internal heating
device is located and normally this capacity of stored bitumen is
unavailable for use.
b) Internal volume above the Available Tank Capacity from the tank vent /
overfill pipework to the roof of the tank.
4. Nominal Tank Capacity (m3
) - Total internal volume of the tank from the floor to
its roof. This capacity is greater than and should not be confused with the Safe
Working Tank Capacity when discussing the tank's available capacity.
5. The Design Engineer may propose changes to the tank design capacities to
optimize or economize the tank fabrication process.
6. Volumetric (m3
) To Mass (tonnes) Conversion Factor - Owner/Operator to
provide the Design Engineer a conservative conversion factor (based on
anticipated lowest bitumen density), or the maximum bitumen storage
temperature for each bitumen grade that may be stored in the tank (generally
lighter grades are less dense/viscous and stored at lower temperatures). A
given mass of bitumen will occupy its largest volume when at its highest storage
temperature. This conversion factor will allow the Owner/Operator and Design
Engineer to convert Safe Working Tank Capacity into tonnes similar to the
delivery vehicles, and later aid the plant operators and hauliers determine
whether the tank can safely receive a delivery of bitumen of known weight
(tonnes) without overfilling the tank.
C. Tank load design considerations unique to Owner/Operator's locality and local code
requirements:
1. Seismic loads.
2. Snow loads.
3. Wind loads:
a) Both magnitude and prevailing direction.
b) Uplift pressure on the roof.
4. Flood loads
7
D. Additional tank design considerations for hot bitumen service conditions
1. Hydrogen Sulphide conditions that may promote hydrogen-induced cracking
and hydrogen sulphide fume generation.
2. Maximum tank design temperature.
3. Maximum bitumen operating temperature.
4. Bitumen vapor pressure at maximum operating temperature.
5. Maximum tank fill rate (rate in).
6. Maximum tank emptying rate (rate out).
7. Cross contamination from low boiling point contaminants (such as water,
emulsions and cut-backs) inadvertently leaking or reversing flow in a common
header, creating potentially hazardous situations.
E. Foundation design considerations for elevated temperature service
1. Consult Geotechnical Engineer to collect information on soil bearing capacity
and settlement data.
2. Stresses may be created in the tank to foundation attachments due to thermal
expansion and contraction of the tank over time.
3. Elevated tank temperatures may evaporate moisture in the supporting soil over
time, especially if there is a high water table or a high moisture content in the
soil and cause either uneven settling or excessive settling of the tank.
4. Anchoring considerations - A tank operating at elevated temperatures may tend
to move over time and create stresses on the tank fittings and attachments.
F. Tank safety equipment considerations
1. The interior of a hot bitumen storage tank is a harsh environment for tank safety
equipment. Due to bitumen's tendencies to vaporise and coke when heated at
high temperatures for long periods of time and to increase its viscosity to the
point of hardening to a solid when cooled, there is a risk that bitumen could foul
tank safety equipment and cause malfunctions. Tank safety equipment should
be designed with this in mind and incorporate adequate design safety factors,
redundancy, robustness and accessibility for inspections and preventative
maintenance.
2. Tank vent design basis
a) Tank breathing due to variations in atmospheric temperatures and
barometric pressures.
b) Maximum tank filling rates coincident with potential temperature increases
and bitumen vaporisation due to tank heating and tank breathing. Tank
vent capacity should also consider the air blowing rate if line air blowing is
used.
8
c) Maximum tank emptying rates coincident with potential temperature
decreases due to shut off of the tank heat and tank breathing.
d) Design safety factor based on the potential risks related to unplanned
scenarios.
1) Fire exposure.
2) Partial vent plugging.
3) Froth-over or boil-over.
4) Internal tank heating devices overheating.
5) Inadequate coverage of tank heating devices causing excessive
localised heating and bitumen vaporisation.
6) Bitumen overflow due to tank contents level alarms malfunctioning,
control valve malfunctioning or electrical failure.
e) Open atmospheric vents may help to reduce plugging risks versus other
designs, such as pressure-vacuum vents or flame-arresting devices which
tend to stick or plug more readily in-service.
f) Heat tracing and minimizing vent / overflow pipework lengths may help
reduce plugging risks.
g) Gauge hatch or manhole cover that lifts under abnormal internal tank
pressure, or roof-to-shell frangible joint for emergency venting, such as
during vent plugging or froth-over situations.
h) Vent / overflow pipework accessibility for inspection and cleaning to
prevent plugging.
3. Bitumen temperature measuring system
a) Multiple measuring devices collect bitumen temperature information inside
the tank:
1) Position two devices at the same level as the draw off nozzle to
compare accuracy and provide redundancy.
2) Position additional device(s) at level(s) higher in the tank to evaluate
mixing efficiency.
b) Position measuring devices far enough from the tank's internal heating
device to ensure a representative bitumen temperature.
9
c) Extend measuring devices sufficiently into the tank interior to obtain a
representative temperature unaffected by lower temperatures near the
tank shell.
d) Readout displays can be installed in multiple locations, such as the plant
control room and tank area.
e) Recording devices may be incorporated into the temperature measuring
system to review and analyze past temperature performances, such as
confirming that specified temperature limits are not exceeded.
f) Clear labeling of individual readout displays may help to promote system
understanding, especially when multiple measuring devices and tanks are
present.
4. Tank contents measuring systems
a) Various technologies are available, such as radar, ultrasonic, microwave
and other gauging devices.
b) Readout displays of both tank bitumen volume and safe ullage are
available.
c) Readout displays visible to the haulier from the bitumen discharge area.
d) Readout displays can be installed in multiple locations, such as the plant
control room, bitumen discharge area and tank area.
e) High and low level alarms may be integrated into a tank contents
measuring system to warn of potentially unsafe overfilling or draw-down
conditions.
f) Clear labeling of individual readout displays may help to promote system
understanding and avoid potentially unsafe overfilling or draw-down
conditions. Clear labeling may also help avoid confusion when multiple
tanks are present.
5. Tank contents level alarms
a) A high level alarm (HLA) and an independent high high level alarm
(HHLA) must be installed on each storage tank. Separate and/or
additional alarms (such as a HHLA), operating independently of the tank
contents measuring system, increase redundancy and reduce the risk of
overfilling due to a malfunction.
10
The activation of the HHLA must be independent of the tank contents
gauging system and set to trigger at the available capacity of the tank less
7œ%.
b) High Level Alarm (HLA) - Generally first alarm during tank filling operations
that signals the tank is approaching or has reached its Safe Working Tank
Capacity (generally amber light and audible signals).
To avoid product spillage whilst the delivery hose/line is being cleared, the
HLA should be set to trigger at the available capacity of the tank less 10%.
d) Low Level Alarm (LLA) - Alarm that signals the tank is approaching its
lower Unavailable Tank Capacity (generally red light and audible signals).
Excessive localised heating could occur if the tank's internal heating
device is not sufficiently covered by bitumen. This could result in
excessive oxidation, hydrocarbon and hydrogen sulphide fume generation,
or pyrophoric deposits forming.
e) Owner/Operator should consult with the Design Engineer to determine
alarm heights in the tank. Their heights should be designed to meet all
applicable specifications, codes, and regulatory requirements, and allow
sufficient time to respond to the alarm before an undesired event occurs
(e.g. upon activation of HLA, haulier closes receipt valve and shuts off
pump before tank overfill occurs).
f) Alarms can be integrated with pump systems to automatically close valves
and shut off pumps if an alarm is activated. A Functional Safety
Assessment (FSA) must be carried out to ensure that for each new plant
and plant modification, arrangements are in place to evaluate the
performance and validation of the Safety Integrated System to ensure that
the identified safety requirements, functionality, integrity and BS EN 61511
requirements are met.
g) Visual light displays should be visible to and audible alarms capable of
being heard by, the haulier from the bitumen discharge area.
h) Visual light displays and audible alarms can be installed in multiple
locations, such as the plant control room, bitumen discharge area, and
tank area.
i) Clear labeling of individual light displays may help to promote system
understanding and avoid confusion when multiple alarms and tanks are
present.
11
G. Tank and related pipework heating system considerations
1. Heating system type (such as hot oil, fired heaters, electric, and steam) may
depend on available utilities and facilities, economic, and safety considerations;
tank heating systems may be implemented via devices internal or external to
the tank.
2. Unsafe situations, such as a potential ignition source due to inadvertent
temperatures above specified temperature limits (including insufficient bitumen
coverage of internal heating devices), may be reduced by incorporating
automatic shutoff systems.
3. Bitumen’s product classification for petroleum products is “Unclassified” as it
has a flash point in excess of 200°C. However the Energy Institute, Model code
of safe practice, Part 11, Bitumen Safety Code states:-
“Due to the slow and variable after reactions which can occur during
storage in heated tankage (giving rise to the evolution of very light
flammable vapours), the flash point is not a reliable indicator of the
temperature at which the product in a confined space is likely to produce
a flammable atmosphere.”
Therefore, under certain confined heating storage conditions, flammable
atmospheres can occur and a subsequent DSEAR Risk Assessment is
required.
As part of that assessment an Area classification must be undertaken, which is
a method of analysing and classifying the environment where explosive gas
atmospheres may occur. The main purpose is to facilitate the proper selection
and installation of apparatus to be used safely in that environment, taking into
account the properties of the flammable materials that will be present. DSEAR
specifically extends the original scope of this analysis to take into account non-
electrical sources of ignition, and mobile equipment that creates an ignition risk.
4. If bitumen is periodically allowed to cool inside the tank, incorporating a vertical
hairpin loop as part of an internal heating coil may help allow adequate
expansion of remelted bitumen trapped beneath a solid layer of product in the
tank.
H. Tank and pipework insulation considerations
1. Non-absorbent types of insulation, such as foam glass, may help reduce the risk
of the insulation absorbing bitumen and hot oil spills and leaks and igniting a
fire.
12
2. Leaving a narrow band around the bottom of the tank uninsulated will allow for
visual inspection of the tank's shell-to-floor joint, and may also help prevent
corrosion by allowing any moisture accumulation behind the insulation to drain.
I. Tank mixing system considerations
1. Tank mixing may help to establish a uniform temperature, reduce stratification
and maintain additive suspension (such as polymers) inside the tank.
2. Potential tank mixing systems include propeller mixers/agitators inside the tank,
and recirculation systems that include pumps outside the tank.
3. A heat exchange system outside the tank can be incorporated into a tank
recirculation system.
4. Internal mixing devices may be incorporated into a tank measuring system to
insure the mixing device automatically shuts before the bitumen level in the tank
decreases enough to expose the mixing device.
J. Tank attachments and accessories - size, projection, placement, elevation,
orientation, and location considerations
1. Bitumen inlet and draw off nozzles, flanges and pipework.
2. Vent / overflow pipework.
3. Temperature sensors (thermowells) for temperature measuring system.
4. Heating system including flanges and pipework.
5. Mixing system including flanges and pipework.
6. Drain valve to safely empty heel capacity for tank cleaning and maintenance.
7. Bitumen sampling valve on tank or dedicated piping.
8. Ladders, stairs and platforms, including handrails.
9. Roof gauging hatches and manways.
10. Anchor bolts and straps.
K. Bitumen Discharge Area considerations
1. Height differential between bitumen discharge area and tank. (See GENERAL
GUIDELINES, paragraph A.6. on page 4.)
2. Receiving pipeline flange should match standard delivery flanges on local
bitumen delivery vehicles. Flanges must be located between 500mm (as
measured from the bottom of the flange face) and 1000mm above ground level
(as measured to the top of the flange face). Access to the customer’s delivery
flange must be such as to allow for safe and easy connection of the delivery
hose.
13
3. Flange security system, such as a unique and separate locking device for each
receiving pipeline, to maintain control of receipts and prevent tank
contamination and overfilling.
4. Segregation from emulsion and cut-back receiving pipelines, to include separate
discharge areas, clear labeling and distinct and different flanges to prevent an
inadvertent connection.
5. System to collect and dispose of bitumen drained from the haulier's hose at the
completion of a delivery.
L. After the design is completed and before construction is started, a Hazardous
Operations Review (HAZOP) or Cold Eyes Review of the entire project must be
completed to help to identify and address any operational and/or safety gaps in the
project.
1. A team of knowledgeable people who are not involved with the project (cold
eyes) representing plant operations, design consultant, general contractor, and
any other group with a large role in the project.
2. The team should identify and evaluate the effect of every possible "what if"
scenario.
M. Maintain "as built" detailed site and fabrication drawings after project completion
1. Interior tank data.
2. All specifications and dimensions.
3. Testing result reports.
4. Handling and rigging requirements for shop-built tanks.
March 2012

Weitere Àhnliche Inhalte

Was ist angesagt?

Devnya plant tour
Devnya plant tourDevnya plant tour
Devnya plant tour
teopetz
 
Presentation FFFT
Presentation FFFTPresentation FFFT
Presentation FFFT
Gunar Krause
 
Foam Assisted Surfactant-Alternating-Gas Injection for Heavy Oil Recovery thr...
Foam Assisted Surfactant-Alternating-Gas Injection for Heavy Oil Recovery thr...Foam Assisted Surfactant-Alternating-Gas Injection for Heavy Oil Recovery thr...
Foam Assisted Surfactant-Alternating-Gas Injection for Heavy Oil Recovery thr...
Antonio B. Mejia Jr.
 
Sewer pipes-and-fittings
Sewer pipes-and-fittingsSewer pipes-and-fittings
Sewer pipes-and-fittings
thanhuce
 
iFluids Tank Inspection services
iFluids Tank Inspection servicesiFluids Tank Inspection services
iFluids Tank Inspection services
John Kingsley
 

Was ist angesagt? (20)

General shop design & construction
General shop design & constructionGeneral shop design & construction
General shop design & construction
 
Process optimization by pneumatic injection of slag
Process optimization by pneumatic injection of slagProcess optimization by pneumatic injection of slag
Process optimization by pneumatic injection of slag
 
Devnya plant tour
Devnya plant tourDevnya plant tour
Devnya plant tour
 
corrocoat newsletter web
corrocoat newsletter webcorrocoat newsletter web
corrocoat newsletter web
 
Api 575 rev.2
Api 575 rev.2Api 575 rev.2
Api 575 rev.2
 
00258 corrosion erosion corrosion protection by mo
00258 corrosion  erosion corrosion protection by mo00258 corrosion  erosion corrosion protection by mo
00258 corrosion erosion corrosion protection by mo
 
Design & operation of topsides gas field
Design & operation of topsides gas fieldDesign & operation of topsides gas field
Design & operation of topsides gas field
 
Presentation FFFT
Presentation FFFTPresentation FFFT
Presentation FFFT
 
HPHT WELL ENGINEERING
HPHT   WELL ENGINEERINGHPHT   WELL ENGINEERING
HPHT WELL ENGINEERING
 
Foam Assisted Surfactant-Alternating-Gas Injection for Heavy Oil Recovery thr...
Foam Assisted Surfactant-Alternating-Gas Injection for Heavy Oil Recovery thr...Foam Assisted Surfactant-Alternating-Gas Injection for Heavy Oil Recovery thr...
Foam Assisted Surfactant-Alternating-Gas Injection for Heavy Oil Recovery thr...
 
LOESCHE: OVERVIEW
LOESCHE: OVERVIEWLOESCHE: OVERVIEW
LOESCHE: OVERVIEW
 
Article global cement magazine paru en mars 2019 - European regional modular...
Article global cement magazine paru en mars 2019  - European regional modular...Article global cement magazine paru en mars 2019  - European regional modular...
Article global cement magazine paru en mars 2019 - European regional modular...
 
apl-brochure
apl-brochureapl-brochure
apl-brochure
 
Shipyard layout improvement
Shipyard layout improvementShipyard layout improvement
Shipyard layout improvement
 
Minergy Corporate presentation
Minergy Corporate presentationMinergy Corporate presentation
Minergy Corporate presentation
 
Powder & Bulk Solids Magazine
 Powder & Bulk Solids Magazine Powder & Bulk Solids Magazine
Powder & Bulk Solids Magazine
 
Sewer pipes-and-fittings
Sewer pipes-and-fittingsSewer pipes-and-fittings
Sewer pipes-and-fittings
 
pipes and fittings
pipes and fittingspipes and fittings
pipes and fittings
 
PD193 FPSO & FLNG DESIGN & tECHNOLOGY -LEVEL 2
PD193 FPSO & FLNG DESIGN & tECHNOLOGY -LEVEL 2PD193 FPSO & FLNG DESIGN & tECHNOLOGY -LEVEL 2
PD193 FPSO & FLNG DESIGN & tECHNOLOGY -LEVEL 2
 
iFluids Tank Inspection services
iFluids Tank Inspection servicesiFluids Tank Inspection services
iFluids Tank Inspection services
 

Andere mochten auch

Opening Railway Station Delft
Opening Railway Station DelftOpening Railway Station Delft
Opening Railway Station Delft
Harm Leseman
 
Bentleys Agribusiness brochure
Bentleys Agribusiness brochureBentleys Agribusiness brochure
Bentleys Agribusiness brochure
Brendan Goulding
 

Andere mochten auch (19)

A Compilation of Motivational Quotes for Inspiration
A Compilation of Motivational Quotes for InspirationA Compilation of Motivational Quotes for Inspiration
A Compilation of Motivational Quotes for Inspiration
 
ĐšĐŸĐœŃ‚Ń€Ń€Đ”Ń„ĐŸŃ€ĐŒĐ°Ń†ĐžŃ ĐČ Đ‘Đ”Đ»Đ°Ń€ŃƒŃĐž
ĐšĐŸĐœŃ‚Ń€Ń€Đ”Ń„ĐŸŃ€ĐŒĐ°Ń†ĐžŃ ĐČ Đ‘Đ”Đ»Đ°Ń€ŃƒŃĐžĐšĐŸĐœŃ‚Ń€Ń€Đ”Ń„ĐŸŃ€ĐŒĐ°Ń†ĐžŃ ĐČ Đ‘Đ”Đ»Đ°Ń€ŃƒŃĐž
ĐšĐŸĐœŃ‚Ń€Ń€Đ”Ń„ĐŸŃ€ĐŒĐ°Ń†ĐžŃ ĐČ Đ‘Đ”Đ»Đ°Ń€ŃƒŃĐž
 
ΣΕΒ, ΔÎČÎŽ. Î”Î”Î»Ï„ÎŻÎż-09.02.17
ΣΕΒ, ΔÎČÎŽ. Î”Î”Î»Ï„ÎŻÎż-09.02.17ΣΕΒ, ΔÎČÎŽ. Î”Î”Î»Ï„ÎŻÎż-09.02.17
ΣΕΒ, ΔÎČÎŽ. Î”Î”Î»Ï„ÎŻÎż-09.02.17
 
Glorious revolution
Glorious revolutionGlorious revolution
Glorious revolution
 
Opening Railway Station Delft
Opening Railway Station DelftOpening Railway Station Delft
Opening Railway Station Delft
 
Bentleys Agribusiness brochure
Bentleys Agribusiness brochureBentleys Agribusiness brochure
Bentleys Agribusiness brochure
 
Class24 chi squaretestofindependenceposthoc(1)
Class24 chi squaretestofindependenceposthoc(1)Class24 chi squaretestofindependenceposthoc(1)
Class24 chi squaretestofindependenceposthoc(1)
 
ΠΟΛ.1188/16
ΠΟΛ.1188/16ΠΟΛ.1188/16
ΠΟΛ.1188/16
 
SaVany
SaVanySaVany
SaVany
 
peerj-1949
peerj-1949peerj-1949
peerj-1949
 
ΩΕΚ 3335 Β΄
ΩΕΚ 3335 Β΄ ΩΕΚ 3335 Β΄
ΩΕΚ 3335 Β΄
 
ΣΕΒ: ΟÎč Î”ÏÎłÎ±Î¶ÏŒÎŒÎ”ÎœÎżÎč στÎčς ÎčÎŽÎčωτÎčÎșές ΔπÎčχΔÎčÏÎźÏƒÎ”Îčς Ξα ÎČÎłÎŹÎ»ÎżÏ…Îœ τη χώρα από τηΜ Îș...
ΣΕΒ:  ΟÎč Î”ÏÎłÎ±Î¶ÏŒÎŒÎ”ÎœÎżÎč στÎčς ÎčÎŽÎčωτÎčÎșές ΔπÎčχΔÎčÏÎźÏƒÎ”Îčς Ξα ÎČÎłÎŹÎ»ÎżÏ…Îœ τη χώρα από τηΜ Îș...ΣΕΒ:  ΟÎč Î”ÏÎłÎ±Î¶ÏŒÎŒÎ”ÎœÎżÎč στÎčς ÎčÎŽÎčωτÎčÎșές ΔπÎčχΔÎčÏÎźÏƒÎ”Îčς Ξα ÎČÎłÎŹÎ»ÎżÏ…Îœ τη χώρα από τηΜ Îș...
ΣΕΒ: ΟÎč Î”ÏÎłÎ±Î¶ÏŒÎŒÎ”ÎœÎżÎč στÎčς ÎčÎŽÎčωτÎčÎșές ΔπÎčχΔÎčÏÎźÏƒÎ”Îčς Ξα ÎČÎłÎŹÎ»ÎżÏ…Îœ τη χώρα από τηΜ Îș...
 
ΔΕΑΩ 1160724 ΕΞ2016
ΔΕΑΩ 1160724 ΕΞ2016ΔΕΑΩ 1160724 ΕΞ2016
ΔΕΑΩ 1160724 ΕΞ2016
 
EÎșτέλΔση Ï€ÏÎżÏ‹Ï€ÎżÎ»ÎżÎłÎčÏƒÎŒÎżÏ OÎșτ.2016
EÎșτέλΔση Ï€ÏÎżÏ‹Ï€ÎżÎ»ÎżÎłÎčÏƒÎŒÎżÏ OÎșτ.2016EÎșτέλΔση Ï€ÏÎżÏ‹Ï€ÎżÎ»ÎżÎłÎčÏƒÎŒÎżÏ OÎșτ.2016
EÎșτέλΔση Ï€ÏÎżÏ‹Ï€ÎżÎ»ÎżÎłÎčÏƒÎŒÎżÏ OÎșτ.2016
 
ΠΟΛ.1198/16
ΠΟΛ.1198/16ΠΟΛ.1198/16
ΠΟΛ.1198/16
 
Đ”ĐșĐŸĐ»ĐŸĐłĐžŃ˜Đ°,ĐČĐŸĐŽĐ°
Đ”ĐșĐŸĐ»ĐŸĐłĐžŃ˜Đ°,ĐČĐŸĐŽĐ°Đ”ĐșĐŸĐ»ĐŸĐłĐžŃ˜Đ°,ĐČĐŸĐŽĐ°
Đ”ĐșĐŸĐ»ĐŸĐłĐžŃ˜Đ°,ĐČĐŸĐŽĐ°
 
The Habitat Camrose Blog
The Habitat Camrose BlogThe Habitat Camrose Blog
The Habitat Camrose Blog
 
Cinch Horizon Distributor Presentation
Cinch Horizon Distributor PresentationCinch Horizon Distributor Presentation
Cinch Horizon Distributor Presentation
 
Î ÏÏŒÎłÏÎ±ÎŒÎŒÎ± ΚοÎčΜωΜÎčÎșÎżÏ Î€ÎżÏ…ÏÎčÏƒÎŒÎżÏ 2016 - 2017
Î ÏÏŒÎłÏÎ±ÎŒÎŒÎ± ΚοÎčΜωΜÎčÎșÎżÏ Î€ÎżÏ…ÏÎčÏƒÎŒÎżÏ 2016 -  2017Î ÏÏŒÎłÏÎ±ÎŒÎŒÎ± ΚοÎčΜωΜÎčÎșÎżÏ Î€ÎżÏ…ÏÎčÏƒÎŒÎżÏ 2016 -  2017
Î ÏÏŒÎłÏÎ±ÎŒÎŒÎ± ΚοÎčΜωΜÎčÎșÎżÏ Î€ÎżÏ…ÏÎčÏƒÎŒÎżÏ 2016 - 2017
 

Ähnlich wie 184648009 new-hot-bitumen-storage-tank-construction-guidelines-march-2012-2

Traceheatingofbitumenpipelines-March2019.pdf
Traceheatingofbitumenpipelines-March2019.pdfTraceheatingofbitumenpipelines-March2019.pdf
Traceheatingofbitumenpipelines-March2019.pdf
amarendratiwari6
 
Technical specifications for Phase 1 Wastewater Network tank interceptors
Technical specifications for Phase 1 Wastewater Network tank interceptorsTechnical specifications for Phase 1 Wastewater Network tank interceptors
Technical specifications for Phase 1 Wastewater Network tank interceptors
Laith Abdel Nabi
 
WP_Extreme_2016 (2)
WP_Extreme_2016 (2)WP_Extreme_2016 (2)
WP_Extreme_2016 (2)
Stephen Streich
 
Coal handling-guidelines
Coal handling-guidelinesCoal handling-guidelines
Coal handling-guidelines
Boudina Oussama
 
Patent 3
Patent 3Patent 3
Patent 3
ram viswam
 

Ähnlich wie 184648009 new-hot-bitumen-storage-tank-construction-guidelines-march-2012-2 (20)

Storage Tank Farms Layout and Piping
Storage Tank Farms Layout and PipingStorage Tank Farms Layout and Piping
Storage Tank Farms Layout and Piping
 
Key Process Considerations for Pipeline Design Basis
Key Process Considerations for Pipeline Design BasisKey Process Considerations for Pipeline Design Basis
Key Process Considerations for Pipeline Design Basis
 
2010 4.1
2010 4.12010 4.1
2010 4.1
 
Truck loading and unloading technical specification
Truck loading and unloading technical specificationTruck loading and unloading technical specification
Truck loading and unloading technical specification
 
Traceheatingofbitumenpipelines-March2019.pdf
Traceheatingofbitumenpipelines-March2019.pdfTraceheatingofbitumenpipelines-March2019.pdf
Traceheatingofbitumenpipelines-March2019.pdf
 
OISD-STD-117 Fire Protection Facilities for Petroleum Depots, Terminals, Pipe...
OISD-STD-117 Fire Protection Facilities for Petroleum Depots, Terminals, Pipe...OISD-STD-117 Fire Protection Facilities for Petroleum Depots, Terminals, Pipe...
OISD-STD-117 Fire Protection Facilities for Petroleum Depots, Terminals, Pipe...
 
NDL FUEL STATION OPERATION
NDL FUEL STATION OPERATIONNDL FUEL STATION OPERATION
NDL FUEL STATION OPERATION
 
s11814-021-0820-6.pdf
s11814-021-0820-6.pdfs11814-021-0820-6.pdf
s11814-021-0820-6.pdf
 
Technical specifications for Phase 1 Wastewater Network tank interceptors
Technical specifications for Phase 1 Wastewater Network tank interceptorsTechnical specifications for Phase 1 Wastewater Network tank interceptors
Technical specifications for Phase 1 Wastewater Network tank interceptors
 
KNPC Volume 3B.pdf
KNPC Volume 3B.pdfKNPC Volume 3B.pdf
KNPC Volume 3B.pdf
 
Planning to Avoid Failure Storage Tanks
Planning to Avoid Failure Storage TanksPlanning to Avoid Failure Storage Tanks
Planning to Avoid Failure Storage Tanks
 
WP_Extreme_2016 (2)
WP_Extreme_2016 (2)WP_Extreme_2016 (2)
WP_Extreme_2016 (2)
 
Coal handling-guidelines
Coal handling-guidelinesCoal handling-guidelines
Coal handling-guidelines
 
Coal processing
Coal processingCoal processing
Coal processing
 
Coal handling-guidelines
Coal handling-guidelinesCoal handling-guidelines
Coal handling-guidelines
 
Es3
Es3Es3
Es3
 
Patent 3
Patent 3Patent 3
Patent 3
 
Mobile hopper tender
Mobile hopper tenderMobile hopper tender
Mobile hopper tender
 
Method statement tank base concrete pouring
Method statement  tank base concrete pouringMethod statement  tank base concrete pouring
Method statement tank base concrete pouring
 
NOx SOx CO2 and Urea Dust Control inFertilizers Plants.pdf
NOx SOx CO2 and Urea Dust Control inFertilizers  Plants.pdfNOx SOx CO2 and Urea Dust Control inFertilizers  Plants.pdf
NOx SOx CO2 and Urea Dust Control inFertilizers Plants.pdf
 

KĂŒrzlich hochgeladen

VIP Call Girls Kheda 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Kheda 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Kheda 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Kheda 7001035870 Whatsapp Number, 24/07 Booking
dharasingh5698
 
VVIP Pune Call Girls Handewadi WhatSapp Number 8005736733 With Elite Staff An...
VVIP Pune Call Girls Handewadi WhatSapp Number 8005736733 With Elite Staff An...VVIP Pune Call Girls Handewadi WhatSapp Number 8005736733 With Elite Staff An...
VVIP Pune Call Girls Handewadi WhatSapp Number 8005736733 With Elite Staff An...
SUHANI PANDEY
 
Indapur - Virgin Call Girls Pune | Whatsapp No 8005736733 VIP Escorts Service...
Indapur - Virgin Call Girls Pune | Whatsapp No 8005736733 VIP Escorts Service...Indapur - Virgin Call Girls Pune | Whatsapp No 8005736733 VIP Escorts Service...
Indapur - Virgin Call Girls Pune | Whatsapp No 8005736733 VIP Escorts Service...
SUHANI PANDEY
 
B2 Interpret the brief.docxccccccccccccccc
B2 Interpret the brief.docxcccccccccccccccB2 Interpret the brief.docxccccccccccccccc
B2 Interpret the brief.docxccccccccccccccc
MollyBrown86
 
VIP Call Girls Mehsana 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Mehsana 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Mehsana 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Mehsana 7001035870 Whatsapp Number, 24/07 Booking
dharasingh5698
 
VVIP Pune Call Girls Sopan Baug WhatSapp Number 8005736733 With Elite Staff A...
VVIP Pune Call Girls Sopan Baug WhatSapp Number 8005736733 With Elite Staff A...VVIP Pune Call Girls Sopan Baug WhatSapp Number 8005736733 With Elite Staff A...
VVIP Pune Call Girls Sopan Baug WhatSapp Number 8005736733 With Elite Staff A...
SUHANI PANDEY
 
High Profile Call Girls in Pune (Adult Only) 8005736733 Escort Service 24x7 ...
High Profile Call Girls in Pune  (Adult Only) 8005736733 Escort Service 24x7 ...High Profile Call Girls in Pune  (Adult Only) 8005736733 Escort Service 24x7 ...
High Profile Call Girls in Pune (Adult Only) 8005736733 Escort Service 24x7 ...
SUHANI PANDEY
 
Top Rated Call Girls In Podanur đŸ“± {7001035870} VIP Escorts Podanur
Top Rated Call Girls In Podanur đŸ“± {7001035870} VIP Escorts PodanurTop Rated Call Girls In Podanur đŸ“± {7001035870} VIP Escorts Podanur
Top Rated Call Girls In Podanur đŸ“± {7001035870} VIP Escorts Podanur
dharasingh5698
 
Corporate Presentation Probe Canaccord Conference 2024.pdf
Corporate Presentation Probe Canaccord Conference 2024.pdfCorporate Presentation Probe Canaccord Conference 2024.pdf
Corporate Presentation Probe Canaccord Conference 2024.pdf
Probe Gold
 
Ambala Escorts Service ☎ 6378878445 ( Sakshi Sinha ) High Profile Call Girls...
Ambala Escorts Service ☎ 6378878445 ( Sakshi Sinha ) High Profile Call Girls...Ambala Escorts Service ☎ 6378878445 ( Sakshi Sinha ) High Profile Call Girls...
Ambala Escorts Service ☎ 6378878445 ( Sakshi Sinha ) High Profile Call Girls...
mriyagarg453
 

KĂŒrzlich hochgeladen (20)

VIP Call Girls Kheda 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Kheda 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Kheda 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Kheda 7001035870 Whatsapp Number, 24/07 Booking
 
VVIP Pune Call Girls Handewadi WhatSapp Number 8005736733 With Elite Staff An...
VVIP Pune Call Girls Handewadi WhatSapp Number 8005736733 With Elite Staff An...VVIP Pune Call Girls Handewadi WhatSapp Number 8005736733 With Elite Staff An...
VVIP Pune Call Girls Handewadi WhatSapp Number 8005736733 With Elite Staff An...
 
(INDIRA) Call Girl Kashmir Call Now 8617697112 Kashmir Escorts 24x7
(INDIRA) Call Girl Kashmir Call Now 8617697112 Kashmir Escorts 24x7(INDIRA) Call Girl Kashmir Call Now 8617697112 Kashmir Escorts 24x7
(INDIRA) Call Girl Kashmir Call Now 8617697112 Kashmir Escorts 24x7
 
(đŸ‘‰ïŸŸ9999965857 )👉 VIP Call Girls Friends Colony 👉 Delhi 👈 : 9999 Cash Payment...
(đŸ‘‰ïŸŸ9999965857 )👉 VIP Call Girls Friends Colony 👉 Delhi 👈 : 9999 Cash Payment...(đŸ‘‰ïŸŸ9999965857 )👉 VIP Call Girls Friends Colony 👉 Delhi 👈 : 9999 Cash Payment...
(đŸ‘‰ïŸŸ9999965857 )👉 VIP Call Girls Friends Colony 👉 Delhi 👈 : 9999 Cash Payment...
 
Dubai Call Girls O525547&19 Calls Girls In Dubai (L0w+Charger)
Dubai Call Girls O525547&19 Calls Girls In Dubai (L0w+Charger)Dubai Call Girls O525547&19 Calls Girls In Dubai (L0w+Charger)
Dubai Call Girls O525547&19 Calls Girls In Dubai (L0w+Charger)
 
Indapur - Virgin Call Girls Pune | Whatsapp No 8005736733 VIP Escorts Service...
Indapur - Virgin Call Girls Pune | Whatsapp No 8005736733 VIP Escorts Service...Indapur - Virgin Call Girls Pune | Whatsapp No 8005736733 VIP Escorts Service...
Indapur - Virgin Call Girls Pune | Whatsapp No 8005736733 VIP Escorts Service...
 
B2 Interpret the brief.docxccccccccccccccc
B2 Interpret the brief.docxcccccccccccccccB2 Interpret the brief.docxccccccccccccccc
B2 Interpret the brief.docxccccccccccccccc
 
VIP Call Girls Mehsana 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Mehsana 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Mehsana 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Mehsana 7001035870 Whatsapp Number, 24/07 Booking
 
Vijayawada ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready F...
Vijayawada ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready F...Vijayawada ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready F...
Vijayawada ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready F...
 
VVIP Pune Call Girls Sopan Baug WhatSapp Number 8005736733 With Elite Staff A...
VVIP Pune Call Girls Sopan Baug WhatSapp Number 8005736733 With Elite Staff A...VVIP Pune Call Girls Sopan Baug WhatSapp Number 8005736733 With Elite Staff A...
VVIP Pune Call Girls Sopan Baug WhatSapp Number 8005736733 With Elite Staff A...
 
High Profile Call Girls in Pune (Adult Only) 8005736733 Escort Service 24x7 ...
High Profile Call Girls in Pune  (Adult Only) 8005736733 Escort Service 24x7 ...High Profile Call Girls in Pune  (Adult Only) 8005736733 Escort Service 24x7 ...
High Profile Call Girls in Pune (Adult Only) 8005736733 Escort Service 24x7 ...
 
Collective Mining | Corporate Presentation - May 2024
Collective Mining | Corporate Presentation - May 2024Collective Mining | Corporate Presentation - May 2024
Collective Mining | Corporate Presentation - May 2024
 
Pakistani Call girls in Ajman +971563133746 Ajman Call girls
Pakistani Call girls in Ajman +971563133746 Ajman Call girlsPakistani Call girls in Ajman +971563133746 Ajman Call girls
Pakistani Call girls in Ajman +971563133746 Ajman Call girls
 
AMG Quarterly Investor Presentation May 2024
AMG Quarterly Investor Presentation May 2024AMG Quarterly Investor Presentation May 2024
AMG Quarterly Investor Presentation May 2024
 
(đŸ‘‰ïŸŸ9999965857 )👉 VIP Call Girls Greater Noida 👉 Delhi 👈 : 9999 Cash Payment...
(đŸ‘‰ïŸŸ9999965857 )👉 VIP Call Girls Greater Noida  👉 Delhi 👈 : 9999 Cash Payment...(đŸ‘‰ïŸŸ9999965857 )👉 VIP Call Girls Greater Noida  👉 Delhi 👈 : 9999 Cash Payment...
(đŸ‘‰ïŸŸ9999965857 )👉 VIP Call Girls Greater Noida 👉 Delhi 👈 : 9999 Cash Payment...
 
Top Rated Call Girls In Podanur đŸ“± {7001035870} VIP Escorts Podanur
Top Rated Call Girls In Podanur đŸ“± {7001035870} VIP Escorts PodanurTop Rated Call Girls In Podanur đŸ“± {7001035870} VIP Escorts Podanur
Top Rated Call Girls In Podanur đŸ“± {7001035870} VIP Escorts Podanur
 
Best investment platform in india-Falcon Invoice Discounting
Best investment platform in india-Falcon Invoice DiscountingBest investment platform in india-Falcon Invoice Discounting
Best investment platform in india-Falcon Invoice Discounting
 
countries with the highest gold reserves in 2024
countries with the highest gold reserves in 2024countries with the highest gold reserves in 2024
countries with the highest gold reserves in 2024
 
Corporate Presentation Probe Canaccord Conference 2024.pdf
Corporate Presentation Probe Canaccord Conference 2024.pdfCorporate Presentation Probe Canaccord Conference 2024.pdf
Corporate Presentation Probe Canaccord Conference 2024.pdf
 
Ambala Escorts Service ☎ 6378878445 ( Sakshi Sinha ) High Profile Call Girls...
Ambala Escorts Service ☎ 6378878445 ( Sakshi Sinha ) High Profile Call Girls...Ambala Escorts Service ☎ 6378878445 ( Sakshi Sinha ) High Profile Call Girls...
Ambala Escorts Service ☎ 6378878445 ( Sakshi Sinha ) High Profile Call Girls...
 

184648009 new-hot-bitumen-storage-tank-construction-guidelines-march-2012-2

  • 1. 1 NEW HOT BITUMEN STORAGE TANK CONSTRUCTION GUIDELINES The information and recommendations in these guidelines are given in good faith and belief in their accuracy at the time of publication, but does not imply any legal liability or responsibility by the Refined Bitumen Association. The Health and Safety at Work Act 1974 and the Management of Health and Safety Regulations 1999 require employers to provide safe systems of work to ensure the safety of their employees and the public. Health and Safety Law imposes duties on both the supplier and the customer to provide safe systems of work. These guidelines are intended to help both parties comply with their respective responsibilities during the transfer, handling, and storing of hot bitumen at hot mix asphalt manufacturing plants, and are not intended to vary the legal responsibility of either party. PURPOSE These guidelines provide hot mix asphalt manufacturing plant Owners/Operators information to aid in designing, fabricating and erecting new hot bitumen storage tanks at their facilities. SCOPE These guidelines are applicable for above-ground atmospheric-pressure hot bitumen bitumen storage tanks that have a maximum design temperature of 260°C (500°F) . The stored product is heated petroleum-derived bitumen products with Open Cup Flash Points above 163°C (325°F), such as penetration grades, oxidised grades and polymer modified bitumen. These guidelines are not applicable for other bitumen products with lower Open Cup Flash Points, such as emulsions and cut-back bitumens. Transferring, handling, and storing hot bitumen expose plant operators and hauliers to inherent hazards: ‱ Thermal burns. ‱ Froth-overs and boil-overs due to contamination by water or lower boiling point hydrocarbons. ‱ Formation and release of hydrogen sulphide. ‱ Formation and release of hydrocarbon fumes. ‱ Formation of flammable vapours. ‱ Creation of ignition sources - pyrophoric deposits, hot surfaces, sparks and open flames. ‱ Falls from elevated work surfaces.
  • 2. 2 Due to these inherent hazards and the complexities involved with designing and constructing hot bitumen storage tanks, Owners/Operators should consult and hire suitably qualified engineering firms when initiating a new tank project. A qualified engineering firm will be knowledgeable in the design/construction process of hot bitumen storage tanks, including all applicable specifications, codes, and regulatory requirements. A qualified engineering firm will develop a tank design that meets these requirements and mitigates the risks of these inherent hazards. These guidelines are general in nature, and intended to aid Owners/Operators in discussions with design engineers, geotechnical engineers, site contractors, fabricators and equipment suppliers contracted to design and construct hot bitumen storage tanks. REFERENCES API Recommended Practice 2023, "Guide for Safe Storage and Handling of Heated Petroleum-Derived Asphalt Products and Crude-Oil Residua", August 2001. API Standard 650, "Welded Tanks for Oil Storage", June 2007. API Standard 2000, "Venting Atmospheric and Low-Pressure Storage Tanks", April 1998. Asphalt Institute Manual Series No. 4 (MS-4), The Asphalt Handbook, 7th edition, 2007. Asphalt Institute Manual Series No. 22 (MS-22), Principles of Construction of Hot-Mix Asphalt Pavements, 2nd edition. ”Guide to Safe Delivery of Bitumen – UK Edition, Refined Bitumen Association. "Guidance for Safe Bitumen Tank Management", Refined Bitumen Association / Mineral Products Association. "RBA Position Paper on the use of Ground-Based Pumps for Bitumen Discharge at Customer Sites", Refined Bitumen Association. Model code of safe practice, Part 11, Bitumen Safety Code (4th edition), Energy Institute. Dangerous Substances and Explosive Atmospheres Regulations 2002. BS EN 61511:2004 Functional Safety – Safety Instrumented Systems for the process industry sector (Part 1 to 3).
  • 3. 3 DEFINITIONS Bitumen Discharge Area: Area within the plant specifically designed to safely offload and receive vehicle deliveries of hot bitumen. The bitumen is pumped from the bitumen discharge area to the hot bitumen storage tank. Boil-over: Fiery tank overflow caused by hot residue from a surface fire in a bitumen tank becoming denser and sinking in the tank to form a hot layer that causes a violent eruption of burning bitumen when the sinking hot layer comes in contact with a water or lower boiling point hydrocarbon layer. Froth-over: Tank overflow caused by hot bitumen being placed over a layer of water or lower boiling point hydrocarbons, causing the water/hydrocarbons to boil and vaporise, pass through the upper layer of bitumen and overflow the tank with hot bitumen. Hot Bitumen: Heated petroleum-based bitumen products with Open Cup Flash Points above 163°C (325°F), and typically stored in the range of 130° - 168°C (265° - 335°F). Open Cup Flash Point: Minimum Cleveland Open Cup Flash temperature as determined by AASHTO T48 and ASTM D 92. Pyrophoric Deposits: Pyrophoric carbonaceous deposits are formed on the roof and walls of bitumen storage tanks due to the condensation of bitumen vapors, which can become a potential ignition source at temperatures between 177°- 190°C (350° - 375°F) due to oxidation when exposed to an influx of air. Pyrophoric iron sulphide deposits are formed due to hydrogen sulphide reacting with the iron in the tank's roof and walls in the presence of moisture, which can also become a potential ignition source due to oxidation when exposed to air. Roof-to-Shell Frangible Joint: Roof-to-shell joint designed to selectively fail due to abnormal internal tank pressure before other joints or connections fail catastrophically. Ullage: Empty interior tank volume available for deliveries of bitumen.
  • 4. 4 GENERAL GUIDELINES A. Site layout considerations 1. Traffic patterns for bitumen delivery vehicles, other vehicles, and personnel on foot within the plant, to include optimising one-way traffic flows and minimising reversing of vehicles. 2. Proximity of bitumen storage tank and bitumen discharge area to other plant operations and traffic patterns of other vehicles The location of the discharge point must avoid surrounding or adjacent operations which could impair safe delivery. 3. Sufficient work space around the tank and equipment: a) Sufficient area to meet future maintenance and testing requirements, such as removing the heating device from the tank for inspection, maintenance, and replacement. b) Reduce the potential risk for trips and falls. 4. In addition to meeting spacing requirements, it may be advantageous to minimise pipe runs between the proposed tank, bitumen discharge area, and plant mixer, due to construction costs, future maintenance and energy costs related to pipe heat tracing and insulation needs. 5. Vent / overflow pipework location – consider the potential exposure of personnel and vehicles should hot bitumen, bitumen fumes, or hydrogen sulphide be released to the atmosphere. 6. Lines of sight between plant personnel (plant control room) and haulier; haulier and tank (vent); and plant personnel (plant control room) and tank. 7. Tank and equipment spill containment. 8. Elevation differential between bitumen discharge area and tank - if the head pressure differential and line friction losses are too great for the delivery vehicle's pump, a ground-based pump may be needed. An added benefit to the installation of a ground-based pump may be the elimination of bitumen deliveries via compressed air discharge systems and their associated hazards. (See "RBA Position Paper on the use of Ground-Based Pumps for Bitumen Discharge at Customer Sites", Refined Bitumen Association, Ltd for additional guidance on ground-based pumps.)
  • 5. 5 9. Terrain contour of site: a) Level working surfaces in key site locations, such as bitumen discharge area, areas around the bitumen tank, pump areas and any work area with an increased likelihood of trips and falls occurring. b) Drainage patterns around key site locations, such as bitumen discharge area; areas around tank, sampling port location, pump area and other areas to minimise: 1) Potential water contact with hot bitumen. 2) Corrosion. 3) Moisture buildup in tank insulation. 4) Potential slips and falls. c) Potential access to public sewers, waterways, or adjoining properties may dictate the need for emergency drainage systems with traps or separators. 10. Emergency equipment and plans, such as locating emergency shower(s) and eye wash stand(s), emergency shut-off switch(es), fire extinguishers, tank vent, and alarm display(s) and horn(s); identifying evacuation route(s); and ensuring required accessibility for fire fighting. 11. Lighting for key work areas. B. Tank size design considerations (See "Guidance for Safe Bitumen Tank Management" or the “Guide to Safe Delivery of Bitumen”, Refined Bitumen Association, Ltd for additional information regarding tank dimensions and defined capacities.) 1. Safe Working Tank Capacity (m3 ) - Owner/Operator to determine how much volume is needed in the tank to store bitumen that will be available for draw off for use in plant manufacturing requirements. The intent is to prevent unplanned run outs, and its capacity is usually determined based upon: a) Bitumen hauling capacity of local delivery vehicles and the projected bitumen availability from suppliers, to include potential delays during periods of peak supply demand (rate in). b) Peak production rate requirements at Owner/Operator's plant (rate out). c) The maximum potential temperature differential, between the minimum temperature of the delivered bitumen and the maximum bitumen storage temperature, should be considered. (See Volumetric to Mass Conversion Factor below in GENERAL GUIDELINES, paragraph B.6.)
  • 6. 6 2. Available Tank Capacity (m3 ) - Design Engineer to calculate by applying a safety factor to the Owner/Operator's desired Safe Working Tank Capacity (safety factor should be endorsed by Owner/Operator). This safety factor is established to allow sufficient time to safely shut down tank filling operations to avoid overfilling the tank, and is based on maximum potential tank filling rates. The Available Tank Capacity comprises the internal volume from the draw off nozzle to the tank vent / overfill pipework. 3. Unavailable Tank Capacity (m3 ) - Determined by the Design Engineer and consisting of both the a) Internal volume from the floor of the tank to the normal draw-off nozzle (undrawable or heel capacity). This is where the tank's internal heating device is located and normally this capacity of stored bitumen is unavailable for use. b) Internal volume above the Available Tank Capacity from the tank vent / overfill pipework to the roof of the tank. 4. Nominal Tank Capacity (m3 ) - Total internal volume of the tank from the floor to its roof. This capacity is greater than and should not be confused with the Safe Working Tank Capacity when discussing the tank's available capacity. 5. The Design Engineer may propose changes to the tank design capacities to optimize or economize the tank fabrication process. 6. Volumetric (m3 ) To Mass (tonnes) Conversion Factor - Owner/Operator to provide the Design Engineer a conservative conversion factor (based on anticipated lowest bitumen density), or the maximum bitumen storage temperature for each bitumen grade that may be stored in the tank (generally lighter grades are less dense/viscous and stored at lower temperatures). A given mass of bitumen will occupy its largest volume when at its highest storage temperature. This conversion factor will allow the Owner/Operator and Design Engineer to convert Safe Working Tank Capacity into tonnes similar to the delivery vehicles, and later aid the plant operators and hauliers determine whether the tank can safely receive a delivery of bitumen of known weight (tonnes) without overfilling the tank. C. Tank load design considerations unique to Owner/Operator's locality and local code requirements: 1. Seismic loads. 2. Snow loads. 3. Wind loads: a) Both magnitude and prevailing direction. b) Uplift pressure on the roof. 4. Flood loads
  • 7. 7 D. Additional tank design considerations for hot bitumen service conditions 1. Hydrogen Sulphide conditions that may promote hydrogen-induced cracking and hydrogen sulphide fume generation. 2. Maximum tank design temperature. 3. Maximum bitumen operating temperature. 4. Bitumen vapor pressure at maximum operating temperature. 5. Maximum tank fill rate (rate in). 6. Maximum tank emptying rate (rate out). 7. Cross contamination from low boiling point contaminants (such as water, emulsions and cut-backs) inadvertently leaking or reversing flow in a common header, creating potentially hazardous situations. E. Foundation design considerations for elevated temperature service 1. Consult Geotechnical Engineer to collect information on soil bearing capacity and settlement data. 2. Stresses may be created in the tank to foundation attachments due to thermal expansion and contraction of the tank over time. 3. Elevated tank temperatures may evaporate moisture in the supporting soil over time, especially if there is a high water table or a high moisture content in the soil and cause either uneven settling or excessive settling of the tank. 4. Anchoring considerations - A tank operating at elevated temperatures may tend to move over time and create stresses on the tank fittings and attachments. F. Tank safety equipment considerations 1. The interior of a hot bitumen storage tank is a harsh environment for tank safety equipment. Due to bitumen's tendencies to vaporise and coke when heated at high temperatures for long periods of time and to increase its viscosity to the point of hardening to a solid when cooled, there is a risk that bitumen could foul tank safety equipment and cause malfunctions. Tank safety equipment should be designed with this in mind and incorporate adequate design safety factors, redundancy, robustness and accessibility for inspections and preventative maintenance. 2. Tank vent design basis a) Tank breathing due to variations in atmospheric temperatures and barometric pressures. b) Maximum tank filling rates coincident with potential temperature increases and bitumen vaporisation due to tank heating and tank breathing. Tank vent capacity should also consider the air blowing rate if line air blowing is used.
  • 8. 8 c) Maximum tank emptying rates coincident with potential temperature decreases due to shut off of the tank heat and tank breathing. d) Design safety factor based on the potential risks related to unplanned scenarios. 1) Fire exposure. 2) Partial vent plugging. 3) Froth-over or boil-over. 4) Internal tank heating devices overheating. 5) Inadequate coverage of tank heating devices causing excessive localised heating and bitumen vaporisation. 6) Bitumen overflow due to tank contents level alarms malfunctioning, control valve malfunctioning or electrical failure. e) Open atmospheric vents may help to reduce plugging risks versus other designs, such as pressure-vacuum vents or flame-arresting devices which tend to stick or plug more readily in-service. f) Heat tracing and minimizing vent / overflow pipework lengths may help reduce plugging risks. g) Gauge hatch or manhole cover that lifts under abnormal internal tank pressure, or roof-to-shell frangible joint for emergency venting, such as during vent plugging or froth-over situations. h) Vent / overflow pipework accessibility for inspection and cleaning to prevent plugging. 3. Bitumen temperature measuring system a) Multiple measuring devices collect bitumen temperature information inside the tank: 1) Position two devices at the same level as the draw off nozzle to compare accuracy and provide redundancy. 2) Position additional device(s) at level(s) higher in the tank to evaluate mixing efficiency. b) Position measuring devices far enough from the tank's internal heating device to ensure a representative bitumen temperature.
  • 9. 9 c) Extend measuring devices sufficiently into the tank interior to obtain a representative temperature unaffected by lower temperatures near the tank shell. d) Readout displays can be installed in multiple locations, such as the plant control room and tank area. e) Recording devices may be incorporated into the temperature measuring system to review and analyze past temperature performances, such as confirming that specified temperature limits are not exceeded. f) Clear labeling of individual readout displays may help to promote system understanding, especially when multiple measuring devices and tanks are present. 4. Tank contents measuring systems a) Various technologies are available, such as radar, ultrasonic, microwave and other gauging devices. b) Readout displays of both tank bitumen volume and safe ullage are available. c) Readout displays visible to the haulier from the bitumen discharge area. d) Readout displays can be installed in multiple locations, such as the plant control room, bitumen discharge area and tank area. e) High and low level alarms may be integrated into a tank contents measuring system to warn of potentially unsafe overfilling or draw-down conditions. f) Clear labeling of individual readout displays may help to promote system understanding and avoid potentially unsafe overfilling or draw-down conditions. Clear labeling may also help avoid confusion when multiple tanks are present. 5. Tank contents level alarms a) A high level alarm (HLA) and an independent high high level alarm (HHLA) must be installed on each storage tank. Separate and/or additional alarms (such as a HHLA), operating independently of the tank contents measuring system, increase redundancy and reduce the risk of overfilling due to a malfunction.
  • 10. 10 The activation of the HHLA must be independent of the tank contents gauging system and set to trigger at the available capacity of the tank less 7Âœ%. b) High Level Alarm (HLA) - Generally first alarm during tank filling operations that signals the tank is approaching or has reached its Safe Working Tank Capacity (generally amber light and audible signals). To avoid product spillage whilst the delivery hose/line is being cleared, the HLA should be set to trigger at the available capacity of the tank less 10%. d) Low Level Alarm (LLA) - Alarm that signals the tank is approaching its lower Unavailable Tank Capacity (generally red light and audible signals). Excessive localised heating could occur if the tank's internal heating device is not sufficiently covered by bitumen. This could result in excessive oxidation, hydrocarbon and hydrogen sulphide fume generation, or pyrophoric deposits forming. e) Owner/Operator should consult with the Design Engineer to determine alarm heights in the tank. Their heights should be designed to meet all applicable specifications, codes, and regulatory requirements, and allow sufficient time to respond to the alarm before an undesired event occurs (e.g. upon activation of HLA, haulier closes receipt valve and shuts off pump before tank overfill occurs). f) Alarms can be integrated with pump systems to automatically close valves and shut off pumps if an alarm is activated. A Functional Safety Assessment (FSA) must be carried out to ensure that for each new plant and plant modification, arrangements are in place to evaluate the performance and validation of the Safety Integrated System to ensure that the identified safety requirements, functionality, integrity and BS EN 61511 requirements are met. g) Visual light displays should be visible to and audible alarms capable of being heard by, the haulier from the bitumen discharge area. h) Visual light displays and audible alarms can be installed in multiple locations, such as the plant control room, bitumen discharge area, and tank area. i) Clear labeling of individual light displays may help to promote system understanding and avoid confusion when multiple alarms and tanks are present.
  • 11. 11 G. Tank and related pipework heating system considerations 1. Heating system type (such as hot oil, fired heaters, electric, and steam) may depend on available utilities and facilities, economic, and safety considerations; tank heating systems may be implemented via devices internal or external to the tank. 2. Unsafe situations, such as a potential ignition source due to inadvertent temperatures above specified temperature limits (including insufficient bitumen coverage of internal heating devices), may be reduced by incorporating automatic shutoff systems. 3. Bitumen’s product classification for petroleum products is “Unclassified” as it has a flash point in excess of 200°C. However the Energy Institute, Model code of safe practice, Part 11, Bitumen Safety Code states:- “Due to the slow and variable after reactions which can occur during storage in heated tankage (giving rise to the evolution of very light flammable vapours), the flash point is not a reliable indicator of the temperature at which the product in a confined space is likely to produce a flammable atmosphere.” Therefore, under certain confined heating storage conditions, flammable atmospheres can occur and a subsequent DSEAR Risk Assessment is required. As part of that assessment an Area classification must be undertaken, which is a method of analysing and classifying the environment where explosive gas atmospheres may occur. The main purpose is to facilitate the proper selection and installation of apparatus to be used safely in that environment, taking into account the properties of the flammable materials that will be present. DSEAR specifically extends the original scope of this analysis to take into account non- electrical sources of ignition, and mobile equipment that creates an ignition risk. 4. If bitumen is periodically allowed to cool inside the tank, incorporating a vertical hairpin loop as part of an internal heating coil may help allow adequate expansion of remelted bitumen trapped beneath a solid layer of product in the tank. H. Tank and pipework insulation considerations 1. Non-absorbent types of insulation, such as foam glass, may help reduce the risk of the insulation absorbing bitumen and hot oil spills and leaks and igniting a fire.
  • 12. 12 2. Leaving a narrow band around the bottom of the tank uninsulated will allow for visual inspection of the tank's shell-to-floor joint, and may also help prevent corrosion by allowing any moisture accumulation behind the insulation to drain. I. Tank mixing system considerations 1. Tank mixing may help to establish a uniform temperature, reduce stratification and maintain additive suspension (such as polymers) inside the tank. 2. Potential tank mixing systems include propeller mixers/agitators inside the tank, and recirculation systems that include pumps outside the tank. 3. A heat exchange system outside the tank can be incorporated into a tank recirculation system. 4. Internal mixing devices may be incorporated into a tank measuring system to insure the mixing device automatically shuts before the bitumen level in the tank decreases enough to expose the mixing device. J. Tank attachments and accessories - size, projection, placement, elevation, orientation, and location considerations 1. Bitumen inlet and draw off nozzles, flanges and pipework. 2. Vent / overflow pipework. 3. Temperature sensors (thermowells) for temperature measuring system. 4. Heating system including flanges and pipework. 5. Mixing system including flanges and pipework. 6. Drain valve to safely empty heel capacity for tank cleaning and maintenance. 7. Bitumen sampling valve on tank or dedicated piping. 8. Ladders, stairs and platforms, including handrails. 9. Roof gauging hatches and manways. 10. Anchor bolts and straps. K. Bitumen Discharge Area considerations 1. Height differential between bitumen discharge area and tank. (See GENERAL GUIDELINES, paragraph A.6. on page 4.) 2. Receiving pipeline flange should match standard delivery flanges on local bitumen delivery vehicles. Flanges must be located between 500mm (as measured from the bottom of the flange face) and 1000mm above ground level (as measured to the top of the flange face). Access to the customer’s delivery flange must be such as to allow for safe and easy connection of the delivery hose.
  • 13. 13 3. Flange security system, such as a unique and separate locking device for each receiving pipeline, to maintain control of receipts and prevent tank contamination and overfilling. 4. Segregation from emulsion and cut-back receiving pipelines, to include separate discharge areas, clear labeling and distinct and different flanges to prevent an inadvertent connection. 5. System to collect and dispose of bitumen drained from the haulier's hose at the completion of a delivery. L. After the design is completed and before construction is started, a Hazardous Operations Review (HAZOP) or Cold Eyes Review of the entire project must be completed to help to identify and address any operational and/or safety gaps in the project. 1. A team of knowledgeable people who are not involved with the project (cold eyes) representing plant operations, design consultant, general contractor, and any other group with a large role in the project. 2. The team should identify and evaluate the effect of every possible "what if" scenario. M. Maintain "as built" detailed site and fabrication drawings after project completion 1. Interior tank data. 2. All specifications and dimensions. 3. Testing result reports. 4. Handling and rigging requirements for shop-built tanks. March 2012