SlideShare ist ein Scribd-Unternehmen logo
1 von 20
Downloaden Sie, um offline zu lesen
TRENCH SHORING
SOLUTIONS
2 // TRENCH SHORING SOLUTIONS	 Contact us: 13 15 52 | TechnicalDesigns@coateshire.com.au
At Coates Hire, we offer the highest quality equipment and we equip our customers with the best expertise in the industry. Our
experts provide advice on evaluating the risks associated with equipment supply, performance and operation. Our Engineering
Services Team offers comprehensive technical support and we can assist in the concept and design of all engineering solutions.
All of which ensures that your site is always performing to its full potential.
Our unique ability to provide total equipment solutions helps you drive both time and cost efficiencies. We have the expertise
to ensure you have everything you need, anytime you need it. So no matter how big or small your project is, you can count on
Coates Hire to help make it happen.
•	 Commitment to Safety: We are passionately
commited to safety, helping deliver your project
on time whilst ensuring you’re meeting duty of
care obligations.
•	 130 Years’ Experience: We have a track record
that spans every market sector, helping to
deliver successful projects across a wide range of
industries
•	 Project Support: Over 600 branch managers,
field sales and product specialists are committed
to providing complete solutions to your specific
project needs.
•	 Industry Leading Customer Service: At
Coates Hire we take customer service seriously
and ensure we are continually improving your
experience.
•	 Engineering and Technical: Our dedicated
team of experts can provide technical solution,
design, certification and installation services for
temporary works requirements.
•	 R&D Capabilities: Our research, development
& innovation arm constantly strives to find new
and better solutions, systems and equipment
for our customers.
OUR EXPERTISE:
// 3	 TRENCH SHORING SOLUTIONS
Aluminium Vertishore
Ideal for trench excavations in cohesive soils (clay), Vertishores are a rapidly deployed solution used to stabilise the walls of an
excavated trench to allow safe access. Vertishores are light enough to be installed by manual handling and can be used for a
range of different trench depths & widths. Perfect for confined sites with limited access to heavy plant and machinery.
ALUMINIUM VERTISHORE SPECIFICATIONS
V450-
900
V450-
1400
V1050-
900
V1050-
1400
V1500-
900
V1500-
1400
V2100-
900
V2100-
1400
V2400-
900
V2400-
1400
Length of rail (mm) 450 450 1070 1070 1500 1500 2130 2130 2440 2440
Width of rail (mm) 209 204 204 204 204 204 204 204 204 204
No. cylinders - 1 1 2 2 2 2 2 2 2 2
Min. trench
width
(mm) 560 865 560 865 560 865 560 865 560 865
Max. trench width (mm) 1740 2300 1740 2300 1740 2300 1740 2300 1740 2300
Stroke (mm) 340 535 340 535 340 535 340 535 340 535
Max. trench depth (mm) - - 2435 2435 2460 2460 3015 3015 3015 3015
Weight per unit (kg) 11 13 23 28 28 32 32 37 43 53
4 // TRENCH SHORING SOLUTIONS	 Contact us: 13 15 52 | TechnicalDesigns@coateshire.com.au
Aluminium Shoring Shields provide an extremely light-weight solution for shielding a work zone inside an excavated trench.
Lowered into position after excavation has been performed, our range of Aluminium Shoring Shields can be easily lifted and
moved using small excavators. This makes them rapid and easy to install, extract, or to move along a trench excavation as
construction progresses. A range of panel & strut sizes are available to suit almost any small to medium size trench excavation.
STANDARD ALUMINIUM SHORING SHIELDS SPECIFICATIONS
Model
(L x H)
Length Height
Pipe Clearance
Length
Clear Working Width
Under Strut
Clearance
Capacity
Box Weight
(min internal)
L H Lc
Bp / Bc
hc
Stat.
Strut
Hyd.
Strut
(kg)
Min Max Es Eh
(m) (m) (m) (m) (m) (m) (kPa) (kPa)
1.8m x 1.8m 1.83 1.83 1.45 0.40/0.63 2.08/2.31 0.56 53 110 378
2.4m x 1.8m 2.44 1.83 1.90 0.40/0.63 2.08/2.31 0.56 53 67 446
1.8m x 2.4m 1.83 2.44 1.45 0.40/0.63 2.08/2.31 0.56 53 81 426
2.4m x 2.4m 2.44 2.44 1.90 0.40/0.63 2.08/2.31 0.56 53 67 505
L
B
bp
hc
Lc
H
tpl
bc
Aluminium Shield Dimension Diagram
Aluminium Shoring Shield
Aluminium Shoring Shields Dimension Diagram
// 5	 TRENCH SHORING SOLUTIONS
Aluminium Shoring Shield
SMOOTH WALL ALUMINIUM SHORING SHIELD SPECIFICATIONS
Model
(L x H)
Length Height
Pipe Clearance
Length
Clear Working Width
Under Strut
Clearance
Capacity
Box Weight
(min
internal)
L H Lc
Bp / Bc
hc E
(kg)Min Max
(m) (m) (m) (m) (m) (m) (kPa)
1.8m x 1.8m 1.83 1.83 1.30 0.40/0.63 2.08/2.31 0.81 105 430
2.4m x 1.8m 2.44 1.83 1.90 0.40/0.63 2.08/2.31 0.81 79 543
1.5m x 2.4m 1.52 2.44 0.99 0.40/0.63 2.08/2.31 1.19 90 454
1.8m x 2.4m 1.83 2.44 1.30 0.40/0.63 2.08/2.31 1.19 80 512
2.4m x 2.4m 2.44 2.44 1.90 0.40/0.63 2.08/2.31 1.19 60 629
3.6m x 2.4m 3.66 2.44 3.12 0.35/0.63 2.03/2.31 1.19 29 859
L
B
bp
hc
Lc
H
tpl
bc
Aluminium Shield Dimension DiagramAluminium Shoring Shield Dimension Diagram
6 // TRENCH SHORING SOLUTIONS	 Contact us: 13 15 52 | TechnicalDesigns@coateshire.com.au
SUPER ALUMINIUM SHIELD – HIGH CLEARANCE CONFIGURATION
Model
Length
Total
Pipe Clearence
Length
Height
Clear Working
Width
Understrut
Clearance
Capacity
Panel
Thickness
Box Weight
(min internal)
L Lc H
bc
hc E tpl
Min Max
(m) (m) (m) (m) (m) (m) (kPa) (mm) (kg)
4.5m Lower Only 4.5 4.0 2.3 1.48 4.48 2.2 42 150 3292
4.5m Lower + Upper 4.5 4.0 4.0 1.48 4.48 2.2 42 150 4736
7.3m Lower Only 7.3 6.8 2.3 1.48 4.48 2.2 36 180 4268
7.3m Lower + Upper 7.3 6.8 4.0 1.48 4.48 2.2 36 180 6612
Shield Dimension Diagram (High Clearance configration)
L
B
bc
tpl
H
hc
Lc
Super Aluminium Shoring Shield
The ultimate aluminium shoring shield. The Super Aluminium Shoring Shield combines the light-weight advantages of
aluminium construction, with a design engineered for strength and size. This produces a shoring shield that allows you to take
your excavation longer, wider & deeper, while still using standard size plant and machinery typically available on a construction
site. The Super Aluminium Shoring Shield is ideal for large trenching and pit applications where productivity is critical.
SUPER ALUMINIUM SHIELD – STANDARD CONFIGURATION (REFER OVER LEAF FOR IMAGE)
Model
Length
Total
Pipe Clearance
Length
Height Clear Working Width
Understrut
Clearance
Capacity
Panel
Thickness
Box Weight
(min
internal)
L Lc H
bc
hc E tpl
Min Max
(m) (m) (m) (m) (m) (m) (kPa) (mm) (kg)
4.5m Lower 4.5 4.0 2.3 1.0 4.0 1.4 42 150 2352
4.5m Upper 4.5 4.0 1.7 1.0 4.0 - 42 150 2064
7.3m Lower 7.3 6.8 2.3 1.0 4.0 1.4 36 180 3400
7.3m Upper 7.3 6.8 1.7 1.0 4.0 - 36 180 2892
Shield Dimension Diagram (Standard Configuration)
HH
L
B
hc
bc
tpl
Lc
Shield Dimension Diagram
(Standard Configuration)
Shield Dimension Diagram
(High Clearance Configuration)
// 7	 TRENCH SHORING SOLUTIONS
Series 100 Light Shield
SERIES 100 LIGHT SHIELD
Model
Length
Total
Pipe Clearence
Length
Height
Clear Working
Width
Understrut
Clearance
Capacity
Panel
Thickness
Box Weight
(min internal)
L Lc H
bc
hc E tpl
Min Max
(m) (m) (m) (m) (m) (m) (kPa) (mm) (kg)
LOWER SHIELD
2.0m x 1.6m 2.0 1.63 1.6 0.6 4.0 1.0 48 60 670
2.0m x 2.0m 2.0 1.63 2.0 0.6 4.0 1.2 48 60 790
2.0m x 2.4m 2.0 1.63 2.4 0.6 4.0 1.2 48 60 900
2.5m x1.6m 2.5 2.13 1.6 0.6 4.0 1.0 38 60 760
2.5m x 2.0m 2.5 2.13 2.0 0.6 4.0 1.2 38 60 890
2.5m x 2.4m 2.5 2.13 2.4 0.6 4.0 1.2 38 60 1020
3.0m x 1.6m 3.0 2.63 1.6 0.6 4.0 1.0 32 60 850
3.0m x 2.0m 3.0 2.63 2.0 0.6 4.0 1.2 32 60 990
3.0m x 2.4m 3.0 2.63 2.4 0.6 4.0 1.2 32 60 1140
UPPER SHIELD
2.0m x 1.0m 2.0 1.63 1.0 0.6 4.0 - 48 60 500
2.5m x 1.0m 2.5 2.13 1.0 0.6 4.0 - 38 60 560
3.0m x 1.0m 3.0 2.63 1.0 0.6 4.0 - 32 60 620
Series 100 Shield Dimension Diagram
L
H
bc
H
H
hc
tpl
Lc
The Series 100 Light Shield is ideal for small to medium pit & trenching excavations where there is limited access to heavy
plant & machinery on site. This efficiently designed shield achieves an excellent pressure capacity rating, while still keeping
the assembled shield weight to a minimum. In addition to this, its steel construction and simple design produces an extremely
robust and versatile shoring solution.
Series 100 Shield Dimension Diagram
8 // TRENCH SHORING SOLUTIONS	 Contact us: 13 15 52 | TechnicalDesigns@coateshire.com.au
Manhole Shoring Box
SERIES 600 MANHOLE SHORING BOX
Model
Length
Total
Pipe Clearence
Length
Height
Clear Working
Width
Understrut
Clearance
Capacity
Panel
Thickness
Box Weight
(min internal)
L Lc H
bc
hc E tpl
Min Max
(m) (m) (m) (m) (m) (m) (kPa) (mm) (kg)
2.5m Lower 2.5 2.1 2.5 1.5 6.8 1.53 50.1 107.0 2356
2.5m Upper 2.5 2.1 1.5 1.5 6.8 - 50.1 107.0 1623
3.0m Lower 3.0 2.6 2.5 1.5 6.8 1.53 41.8 107.0 2737
3.0m Upper 3.0 2.6 1.5 1.5 6.8 - 41.8 107.0 1987
M41 MANHOLE SHORING BOX (WA & NT ONLY)
Model
Length
Total
Pipe Clearence
Length
Height
Clear Working
Width
Understrut
Clearance
Capacity
Panel
Thickness
Box Weight
(min internal)
L Lc H
bc
hc E tpl
Min Max
(m) (m) (m) (m) (m) (m) (kPa) (mm) (kg)
2.6m Lower 2.6 2.2 2.5 1.6 5.0 1.50 41.0 108.0 3140
2.6m Upper 2.6 2.2 1.5 1.6 5.0 - 41.0 108.0 1970
3.0m Lower 3.0 2.6 2.5 1.6 5.0 1.50 41.0 108.0 3530
3.0m Upper 3.0 2.6 1.5 1.6 5.0 - 41.0 108.0 2170
Manhole boxes are ideal for construction of manholes and chambers along a linear excavation such as a pipe installation. Our
range of manhole boxes are designed to be flexible, robust, and suit most typical manhole construction sizes.
Manhole Box Dimension Diagram
LB
bc
tpl
Lc
HH
hc
Manhole Box Dimension Diagram
// 9	 TRENCH SHORING SOLUTIONS
Series 600 Standard Box
SERIES 600 STANDARD SHORING BOX– STANDARD CONFIGURATION
Model
Length
Total
Pipe Clearence
Length
Height
Clear Working
Width
Understrut
Clearance
Capacity
Panel
Thickness
Box Weight
(min internal)
L Lc H
bc
hc E tpl
Min Max
(m) (m) (m) (m) (m) (m) (kPa) (mm) (kg)
3.0m Lower 3.0 2.6 2.4 0.7 6.0 1.53 53.5 107.0 2022
3.0m Upper 3.0 2.6 1.4 0.7 6.0 - 53.5 107.0 1236
3.5m Lower 3.5 3.1 2.4 0.7 6.0 1.53 48.9 107.0 2150
3.5m Upper 3.5 3.1 1.4 0.7 6.0 - 48.9 107.0 1350
4.0m Lower 4.0 3.6 2.4 0.7 6.0 1.53 40.1 107.0 2572
4.0m Upper 4.0 3.6 1.4 0.7 6.0 - 40.1 107.0 1586
4.0m HD Lower 4.0 3.6 2.5 0.7 6.0 1.53 70.0 127.0 3012
4.0m HD Upper 4.0 3.6 1.4 0.7 6.0 - 70.0 127.0 1806
5.0m Lower 5.0 4.6 2.4 0.7 6.0 1.53 38.0 127.0 3290
5.0m Upper 5.0 4.6 1.4 0.7 6.0 - 38.0 127.0 2136
6.0m Lower 6.0 5.6 2.4 0.7 6.0 1.53 27.6 127.0 4172
6.0m Upper 6.0 5.6 1.4 0.7 6.0 - 27.6 127.0 3086
6.0m HD Lower 6.0 5.6 2.4 0.7 6.0 1.53 40.0 130.0 4432
6.0m HD Upper 6.0 5.6 1.4 0.7 6.0 - 40.0 130.0 2786
The Series 600 Shoring Box range provides a shoring solution for almost any medium to large sized pit or trench excavation.
With an extensive range of high capacity panels and struts, the Series 600 Box can be assembled to a vast array of different
sizes to suit your needs. This system is designed to be high capacity and extremely robust enabling it to stand up to the most
challenging of site conditions. It can be installed as a traditional shoring shield, or using the “dig & push” method which is ideal
for installation in weak or unstable ground.
Series 600 Standard Box Dimention Diagram-Standard Configration
bc
HH
Lc
tpl
L
B
hc
Series 600 Standard Box Dimension Diagram
(Standard Configuration)
10 //TRENCH SHORING SOLUTIONS	 Contact us: 13 15 52 | TechnicalDesigns@coateshire.com.au
Series 600 Standard Box
SERIES 600 STANDARD SHORING BOX – HIGH CLEARANCE CONFIGURATION (LOWER + UPPER)
Model
Length
Total
Pipe Clearence
Length
Height
Clear Working
Width
Understrut
Clearance
Capacity
Panel
Thickness
Box Weight
(min internal)
L Lc H
bc
hc E tpl
Min Max
(m) (m) (m) (m) (m) (m) (kPa) (mm) (kg)
3.0m 3.0 2.6 3.7 1.03 6.33 2.3 49.9 107.0 4944
3.5m 3.5 3.1 3.7 1.03 6.33 2.3 42.8 107.0 5396
4.0m 4.0 3.6 3.7 1.03 6.33 2.3 37.4 107.0 5844
5.0m 5.0 4.6 3.7 1.03 6.33 2.3 29.9 127.0 7112
6.0m 6.0 5.6 3.7 1.03 6.33 2.3 24.9 127.0 8944
To further increase the versatility of the Series 600 Box, a High Clearance option is available. This provides all of the features &
benefits of the Standard Configuration, with a significantly increased clearance under the lowest strut. Ideal for installation of
large pipes & culverts.
Series 600 Standard Box Dimension Diagram-High Clearance Configration
L
B
bc
tpl
hc
H
Lc
Series 600 Standard Box Dimension Diagram
(High Clearance Configuration)
// 11	 TRENCH SHORING SOLUTIONS
M41 Standard Box (WA & NT Only)
M41 STANDARD SHORING BOX – STANDARD CONFIGURATION
Model
Length
Total
Pipe Clearence
Length
Height
Clear Working
Width
Understrut
Clearance
Capacity
Panel
Thickness
Box Weight
(min internal)
L Lc H
bc
hc E tpl
Min Max
(m) (m) (m) (m) (m) (m) (kPa) (mm) (kg)
3.6m Lower 3.6 3.34 2.5 0.6 4.0 1.50 41.0 108.0 2792
3.6m Upper 3.6 3.34 1.5 0.6 4.0 - 41.0 108.0 1796
4.0m Lower 4.0 3.74 2.5 0.6 4.0 1.50 41.0 108.0 3142
4.0m Upper 4.0 3.74 1.5 0.6 4.0 - 41.0 108.0 2046
M41 STANDARD SHORING BOX – HIGH CLEARANCE CONFIGURATION (LOWER + UPPER)
Model
Length
Total
Pipe Clearence
Length
Height
Clear Working
Width
Understrut
Clearance
Capacity
Panel
Thickness
Box Weight
(min internal)
L Lc H
bc
hc E tpl
Min Max
(m) (m) (m) (m) (m) (m) (kPa) (mm) (kg)
3.6m 3.6 3.34 4.0 1.10 4.75 2.6 41.0 108.0 6060
4.0m 4.0 3.74 4.0 1.10 4.75 2.6 41.0 108.0 6660
The M41 Standard Box range is designed to be high capacity and extremely robust, enabling it to stand up to the most
challenging of site conditions. It can be installed as a traditional shoring shield, or using the “dig & push” method which is ideal
for installation in weak or unstable ground. To further increase the versatility of the M41 Standard Box , a High Clearance option
is available. This provides all of the features & benefits of the Standard Configuration, with a significantly increased clearance
under the lowest strut. Ideal for installation of large pipes & culverts.
M41 Standard Box Dimension Diagram-Standard Configuration
H
H
L
B
bc
tpl
hc
Lc
M41 Standard Box Dimension Diagram-High Clearance Configuration
LB
bc
H
hc
Lc
tpl
M41 Standard Box Dimension Diagram
(Standard Configuration)
M41 Standard Box Dimension Diagram
(High Clearance Configuration)
12 //TRENCH SHORING SOLUTIONS	 Contact us: 13 15 52 | TechnicalDesigns@coateshire.com.au
Rolling Strut Box
SERIES 600 ROLLING STRUT BOX
Model
Length
Total
Pipe Clearence
Length
Height
Clear Working
Width
Understrut
Clearance
Panel
Capacity*
Panel
Thickness
Box Weight
(min internal)
L Lc H
bc
hc E tpl
Min Max
(m) (m) (m) (m) (m) (m) (kPa) (mm) (kg)
3.0m (SSR Strut)
3.0 2.3
3.7 2.69 > 6.0
1.2 - 2.5
53.5 107.0
5760
3.0m (DSR Strut) 1.9 - 1.5 6480
3.5m (SSR Strut)
3.5 2.8
1.2 - 2.5
48.9 107.0
6212
3.5m (DSR Strut) 1.9 - 1.5 6932
4.0m (SSR Strut)
4.0 3.3
1.2 - 2.5
40.1 107.0
6660
4.0m (DSR Strut) 1.9 - 1.5 7380
4.0m HD (SSR Strut)
4.0 3.3
1.2 - 2.5
70.0 127.0
7320
4.0m HD (DSR Strut) 1.9 - 1.5 8040
5.0m (SSR Strut)
5.0 4.3
1.2 - 2.5
38.0 127.0
7928
5.0m (DSR Strut) 1.9 - 1.5 8648
6.0m (SSR Strut)
6.0 5.3
1.2 - 2.5
27.6 127.0
9760
6.0m (DSR Strut) 1.9 - 1.5 10480
6.0m HD (SSR Strut)
6.0 5.3
1.2 - 2.5
40.0 130.0
9720
6.0m HD (DSR Strut) 1.9 - 1.5 10440
Rolling Strut Boxes are ideal for applications where extremely wide excavation dimensions are required. The bolt-together strut
assembly means that there is no fixed limit to strut length, subject to a free-of-charge design review by Coates Hire’s team of
in-house engineers. Added to this the flexibility of the rolling strut allows variable strut positioning to enable the user to avoid
obstructions within the excava-tion zone during excavation & construction.
*Capacity subject to confirmation by a suitably qualified engineer.
“SSR” = Single Slide Rail (ref. following section)
“DSR” = Double Slide Rail (ref. following section)
Series 600 Rolling Strut Box-Std. Configuration
L
B
bc
tpl
hc
H
Lc
Series 600 Rolling Strut Box (Standard Configuration)
// 13	 TRENCH SHORING SOLUTIONS
Rolling Strut Box
7.4M LARGE ROLLING STRUT BOX
Model
Length
Total
Pipe Clearence
Length
Height
Clear Working
Width
Understrut
Clearance
Panel
Capacity
Panel
Thickness
Box Weight
(min internal)
L Lc H
bc
hc E tpl
Min Max
(m) (m) (m) (m) (m) (m) (kPa) (mm) (kg)
Lower
7.4 6.4
2.4 1.35
> 6.0
1.56 57.0 170.0 8840
Upper 1.6 1.35 - 57.0 170.0 6940
High Clear 4.0 1.85 2.50 53.0 170.0 17220
7.4 Large Rolling Strut Box-High Clearance Configuration
L
B
bc
tpl
H
hc
Lc
7.4 Large Rolling Strut Box (High Clearence Configuration)
14 //TRENCH SHORING SOLUTIONS	 Contact us: 13 15 52 | TechnicalDesigns@coateshire.com.au
Slide Rail Shoring—Trench Configuration
SINGLE SLIDE RAIL*
Panel Type
(Length)
Module
Length
Pipe Clearence
Length
Height Clear Working Width
Understrut
Clearance
Panel
Capacity
Panel
Thickness
Ls Lc H
bc
hc E tpl
Min Max
(m) (m) (m) (m) (m) (m) (kPa) (mm)
2.0m 2.27 1.84
2.4 - 3.8 1.25 >6.0^ 0.99 - 2.31
158.0 107.0
3.0m 3.27 2.84 148.0 130.0
4.0m 4.27 3.84 66.0 107.0
4.0m HD 4.27 3.84 82.0 130.0
6.0m 6.27 5.84 60.0 150.0
7.4m 7.67 7.20 57.0 180.0
DOUBLE SLIDE RAIL*
Panel Type
(Length)
Module
Length
Pipe Clearence
Length
Height Clear Working Width
Understrut
Clearance
Panel
Capacity
Panel
Thickness
Ls Lc H
bc
hc E tpl
Min Max
(m) (m) (m) (m) (m) (m) (kPa) (mm)
2.0m 2.27 1.84
2.4 - 9.0 1.25 >6.0^ 1.42—3.42
158.0 107.0
3.0m 3.27 2.84 148.0 130.0
4.0m 4.27 3.84 66.0 107.0
4.0m HD 4.27 3.84 82.0 130.0
6.0m 6.27 5.84 60.0 150.0
7.4m 7.67 7.20 57.0 180.0
Slide Rail is the ultimate in steel shoring solutions. It is the most robust & flexible shoring method for large excavations on the
market, and allows you to take your excavations longer, wider & deeper than with any other product. It offers unrivalled pressure
rating, allowing excavation depths of up to 9.0m in most conditions, and offers the largest under-strut clearance of any product
on the market.
*All applications of Slide Rail should be assessed by a
suitably qualified engineer.
^Additional strut lengths are achievable depending
on the application.
Slide Rail Dimension Diagram-Trench Configuration
L
B
tpl
bc
H
Lc
hc
Slide Rail Dimension Diagram-Trench Configuration
// 15	 TRENCH SHORING SOLUTIONS
Slide Rail Shoring—Pit Shoring Configuration*
SLIDE RAIL SHORING—PIT SHORING CONFIGURATION*
Pit Size
(Panel Length x Panel Length)
Module
Length
Internal
Clearance
Length
Module
Width
Internal
Clearance
Width
Height
(Single Slide Rail
Configuration)
Height
(Single Slide Rail
Configuration)
Minimum
Panel Capacity
Ls Lc B bc H H E
(m) (m) (m) (m)
Min Max Min Max
(kPa)
(m) (m) (m) (m)
2.0m x 2.0m 2.5 2.2 2.5 2.2
2.4 3.8 2.4 9.0
REFER
SLIDE
RAIL
SHORING
TRENCH
CONFIG.
SECTION
2.0m x 3.0m 2.5 2.2 3.5 3.2
2.0m x 4.0m 2.5 2.2 4.5 4.2
2.0m x 6.0m 2.5 2.2 6.5 6.2
2.0m x 7.4m 2.5 2.2 8.3 7.3
3.0m x 3.0m 3.5 3.2 3.5 3.2
3.0m x 4.0m 3.5 3.2 4.5 4.2
3.0m x 6.0m 3.5 3.2 6.5 6.2
3.0m x 7.4m 3.5 3.2 8.3 7.3
4.0m x 4.0m 4.5 4.2 4.5 4.2
4.0m x 6.0m 4.5 4.2 6.5 6.2
4.0m x 7.4m 4.5 4.2 8.3 7.3
6.0m x 6.0m 6.5 6.2 6.5 6.2
6.0m x 7.4m 6.5 6.2 8.3 7.3
7.4m x 7.4m 8.3 7.3 8.3 7.3
To add to Slide Rail’s extensive range of capabilities, the addition of 90 degree corner posts allows for fully enclosed pit
excavations to be achieved. Using the corner posts with the extensive range of panels, and their extremely high pressure rating,
almost any size pit excava-tion can be shored.
Slide Rail Diamension Diagram-Pit Shoring Configration
L B
H
bc
Lc
*All applications of Slide Rail should
be assessed by a suitably qualified engineer.
Slide Rail Dimension Diagram-Pit Shoring Configuration
16 //TRENCH SHORING SOLUTIONS	 Contact us: 13 15 52 | TechnicalDesigns@coateshire.com.au
Safety
•	 Safety is embodied in everything we do and we
work closely with our customers to create the
safest working environment possible
•	 Our complete range of excavation safety
products are NATA tested & accredited and
compliant to Australian Standards
EDGE PROTECTION
Coates Hire edge protection hand rails are compatible
with our entire fleet of aluminium and steel shoring
panels. The adjustable hand rail unit provides a
flexible and rapid solution for edge protection around
excavations of any size. The hand rail units are light-
weight and in full compliance with AS1657.
RESCUE SYSTEMS
The Coates Hire davit rescue system provides a fast and easy solution to meeting
safety requirements associated with working in deep excavations. The simple design
clamps onto the side of any Coates Hire shoring panel, making installation fast & user
friendly. All davit systems are supplied as a comprehensive kit in a secure, lockable
storage case.
EDGE PROTECTION
Model
Length Height Weight
(m) (m) (kg)
3m 3.0 1.0 19.8
4m 4.0 1.0 21.6
// 17	 TRENCH SHORING SOLUTIONS
Safety
LADDER ACCESS SYSTEMS & PLATFORMS
Means of access and egress into deep excavations can often pose an issue on sites where space is at a premium. To provide a
simple and cost effective solution to this challenge, Coates Hire carries a range of temporary access systems which are fast and
easy to install, and do not require a specialist contractor.
18 //TRENCH SHORING SOLUTIONS	 Contact us: 13 15 52 | TechnicalDesigns@coateshire.com.au
Engineering & Technical Support
EMS 648129FS 648130 OHS 648128 OHS 648127
*Environmental certification (ISO4001) achieved at Head Office and an expanding number of branches.
At Coates Hire, we have been providing a wide range of specialist
equipment and services for over 130 years. We pride ourselves
in providing much more than just our product range. Our aim
is to meet our customers’ safety, compliance, productivity,
environmental and cost management expectations.
Our equipment offering is supported by an in-house Temporary
Works Department of highly trained and fully qualified Certifying
Engineers, Design Engineers & Drafters, Regional Sales Engineers
and Product Specialists.
This allows us to provide a level of Engineering & Technical support
for your project like no other supplier in the market.
KEY CAPABILITIES
•	 Fully qualified National Engineering department with
extensive experience in temporary works design &
installation
•	 Professionally presented design solutions & drawings using
the latest CAD software
•	 Tender support packages for estimators and planning
functions including budget costing
•	 Support for site teams to develop best solutions and cost
effective design options to keep within timescales and
budget expectations
•	 Engineering design sign off and installation sign off
provided with equipment hire (CPEng, NER, RPEQ)
•	 Risk Assessments both generic and project-specific
•	 Safety in design
•	 Develop safe and sustainable solutions
•	 Training and coaching of site staff in all products via a range
of tool box talks and ongoing support to help keep projects
on track and provide safest possible working environment
•	 ISO Accredited for Quality, Environmental, & OHS
Management
Access
Air & Air Accessories
Compaction
Concrete & Masonry
Earthmoving
Floor and Cleaning Equipment
Generators & Power Distribution
Industrial tools & Equipment
Ladders & Scaffold
Landscaping
Lift & Shift
Lighting
Materials Handling
Portable Buildings & Toilets
Propping
Pumps & Fluid Management
Shoring
Tools & Equipment
Traffic Management
Training (RTO)
Trucks, Vehicles & Trailers
Welding
COATES HIRE’S AVAILABLE PRODUCT RANGE:
At Coates Hire, you’ll find an unmatched range of equipment, available and ready to hire.
We stock Australia’s largest fleet from general hire gear and specialist products, to total site solutions.
With the largest branch network in Australia, you are backed by one of the country’s largest delivery networks.
WhileCoatesHiremakeseveryefforttosupplytheequipment
described and pictured in this brochure, all equipment
offered is subject to availability. Should Coates Hire through
whatever circumstances need to offer an alternative make
or model, customers can be assured that this will be of the
same quality as the item shown or displayed in this brochure.
All information about equipment in this brochure is to the
best of our knowledge correct, but we would urge customers
to check all details at the time of hire or enquiry. Coates Hire
reserves the right to change information without prior notice.
ISSUE1.0

Weitere ähnliche Inhalte

Was ist angesagt?

gantry crane report
gantry crane reportgantry crane report
gantry crane report
Julia Collins
 
Iii design-of-steel-structures-unit-2
Iii design-of-steel-structures-unit-2Iii design-of-steel-structures-unit-2
Iii design-of-steel-structures-unit-2
saibabu48
 
52436966 lecture-13-plate-girders
52436966 lecture-13-plate-girders52436966 lecture-13-plate-girders
52436966 lecture-13-plate-girders
Saleem Malik
 

Was ist angesagt? (20)

steel structural basics
steel structural basicssteel structural basics
steel structural basics
 
Design methods for torsional buckling of steel structures
Design methods for torsional buckling of steel structuresDesign methods for torsional buckling of steel structures
Design methods for torsional buckling of steel structures
 
Guide for the design of crane supporting steel structures
Guide for the design of crane supporting steel structuresGuide for the design of crane supporting steel structures
Guide for the design of crane supporting steel structures
 
gantry crane report
gantry crane reportgantry crane report
gantry crane report
 
Tubing standard
Tubing standardTubing standard
Tubing standard
 
Rcs1-Chapter2-Standards
Rcs1-Chapter2-StandardsRcs1-Chapter2-Standards
Rcs1-Chapter2-Standards
 
PHC pile Installation methods
PHC  pile Installation methodsPHC  pile Installation methods
PHC pile Installation methods
 
Study of Bridge Bearings
Study of Bridge BearingsStudy of Bridge Bearings
Study of Bridge Bearings
 
Iii design-of-steel-structures-unit-2
Iii design-of-steel-structures-unit-2Iii design-of-steel-structures-unit-2
Iii design-of-steel-structures-unit-2
 
CE72.52 - Lecture 3a - Section Behavior - Flexure
CE72.52 - Lecture 3a - Section Behavior - FlexureCE72.52 - Lecture 3a - Section Behavior - Flexure
CE72.52 - Lecture 3a - Section Behavior - Flexure
 
Bs 8100 3-1999
Bs 8100 3-1999Bs 8100 3-1999
Bs 8100 3-1999
 
Design of steel beams
Design of steel beamsDesign of steel beams
Design of steel beams
 
52436966 lecture-13-plate-girders
52436966 lecture-13-plate-girders52436966 lecture-13-plate-girders
52436966 lecture-13-plate-girders
 
Strut and Tie Model for Pile Cap
Strut and Tie Model for Pile CapStrut and Tie Model for Pile Cap
Strut and Tie Model for Pile Cap
 
Composite deck bridge systems
Composite deck bridge systemsComposite deck bridge systems
Composite deck bridge systems
 
Building Structure Project 1 Analysis Report
Building Structure Project 1 Analysis ReportBuilding Structure Project 1 Analysis Report
Building Structure Project 1 Analysis Report
 
Expansion joints in bridge
Expansion joints in bridgeExpansion joints in bridge
Expansion joints in bridge
 
CE 72.52 - Lecture 5 - Column Design
CE 72.52 - Lecture 5 - Column DesignCE 72.52 - Lecture 5 - Column Design
CE 72.52 - Lecture 5 - Column Design
 
Numerical Modelling of Masonry Infill Walls Participation in the Seismic Beha...
Numerical Modelling of Masonry Infill Walls Participation in the Seismic Beha...Numerical Modelling of Masonry Infill Walls Participation in the Seismic Beha...
Numerical Modelling of Masonry Infill Walls Participation in the Seismic Beha...
 
CE72.52 - Lecture 3b - Section Behavior - Shear and Torsion
CE72.52 - Lecture 3b - Section Behavior - Shear and TorsionCE72.52 - Lecture 3b - Section Behavior - Shear and Torsion
CE72.52 - Lecture 3b - Section Behavior - Shear and Torsion
 

Ă„hnlich wie Coates Hire - Trench Shoring Solutions

Coiled Tubing Introduction and Basics.pdf
Coiled Tubing Introduction and Basics.pdfCoiled Tubing Introduction and Basics.pdf
Coiled Tubing Introduction and Basics.pdf
salem123gmaal
 
Clt mtb seminar_presentation_five
Clt mtb seminar_presentation_fiveClt mtb seminar_presentation_five
Clt mtb seminar_presentation_five
FWPA
 
Thomson Linear Super Metric Ball Bushing Bearings
Thomson Linear Super Metric Ball Bushing Bearings Thomson Linear Super Metric Ball Bushing Bearings
Thomson Linear Super Metric Ball Bushing Bearings
Electromate
 
Thomson super metric_ball_bushing_bearings_specsheet
Thomson super metric_ball_bushing_bearings_specsheetThomson super metric_ball_bushing_bearings_specsheet
Thomson super metric_ball_bushing_bearings_specsheet
Electromate
 
Thomson BSA Advanced Anti-Backlash Supernuts XCM 1800
Thomson BSA Advanced Anti-Backlash Supernuts XCM 1800Thomson BSA Advanced Anti-Backlash Supernuts XCM 1800
Thomson BSA Advanced Anti-Backlash Supernuts XCM 1800
Electromate
 
MAIN CANOPY BAJAJ HR(22.09.2016)
MAIN CANOPY BAJAJ HR(22.09.2016)MAIN CANOPY BAJAJ HR(22.09.2016)
MAIN CANOPY BAJAJ HR(22.09.2016)
sufiyan shaikh
 
Presentation of Convert Scrap To Prime Materials without hold production.
Presentation of Convert Scrap To Prime Materials without hold production.Presentation of Convert Scrap To Prime Materials without hold production.
Presentation of Convert Scrap To Prime Materials without hold production.
Abdulrahman Tarbaq
 

Ă„hnlich wie Coates Hire - Trench Shoring Solutions (20)

BHUSHAN STEEL.pdf BROCHURE FOR STEEL TABLE
BHUSHAN STEEL.pdf BROCHURE FOR STEEL TABLEBHUSHAN STEEL.pdf BROCHURE FOR STEEL TABLE
BHUSHAN STEEL.pdf BROCHURE FOR STEEL TABLE
 
Coiled Tubing Introduction and Basics.pdf
Coiled Tubing Introduction and Basics.pdfCoiled Tubing Introduction and Basics.pdf
Coiled Tubing Introduction and Basics.pdf
 
Clt mtb seminar_presentation_five
Clt mtb seminar_presentation_fiveClt mtb seminar_presentation_five
Clt mtb seminar_presentation_five
 
Bricking Solutions Product Catalog
Bricking Solutions Product CatalogBricking Solutions Product Catalog
Bricking Solutions Product Catalog
 
Bricking Solutions Product Catalog
Bricking Solutions Product CatalogBricking Solutions Product Catalog
Bricking Solutions Product Catalog
 
Thomson Linear Super Metric Ball Bushing Bearings
Thomson Linear Super Metric Ball Bushing Bearings Thomson Linear Super Metric Ball Bushing Bearings
Thomson Linear Super Metric Ball Bushing Bearings
 
Thomson super metric_ball_bushing_bearings_specsheet
Thomson super metric_ball_bushing_bearings_specsheetThomson super metric_ball_bushing_bearings_specsheet
Thomson super metric_ball_bushing_bearings_specsheet
 
Strength Of Materials Lab Equipments
Strength Of Materials Lab EquipmentsStrength Of Materials Lab Equipments
Strength Of Materials Lab Equipments
 
MEKA CRUSHING SCREENING AND CONCRETE BATCHING TECHNOLOGIES
MEKA CRUSHING SCREENING AND CONCRETE BATCHING TECHNOLOGIESMEKA CRUSHING SCREENING AND CONCRETE BATCHING TECHNOLOGIES
MEKA CRUSHING SCREENING AND CONCRETE BATCHING TECHNOLOGIES
 
Thomson bsa xcm_specsheet
Thomson bsa xcm_specsheetThomson bsa xcm_specsheet
Thomson bsa xcm_specsheet
 
Thomson BSA Advanced Anti-Backlash Supernuts XCM 1800
Thomson BSA Advanced Anti-Backlash Supernuts XCM 1800Thomson BSA Advanced Anti-Backlash Supernuts XCM 1800
Thomson BSA Advanced Anti-Backlash Supernuts XCM 1800
 
Hydra Solid Carbide Replaceable Head Drills
Hydra Solid Carbide Replaceable Head DrillsHydra Solid Carbide Replaceable Head Drills
Hydra Solid Carbide Replaceable Head Drills
 
MAIN CANOPY BAJAJ HR(22.09.2016)
MAIN CANOPY BAJAJ HR(22.09.2016)MAIN CANOPY BAJAJ HR(22.09.2016)
MAIN CANOPY BAJAJ HR(22.09.2016)
 
Ged 2473
Ged 2473Ged 2473
Ged 2473
 
Presentation of Convert Scrap To Prime Materials without hold production.
Presentation of Convert Scrap To Prime Materials without hold production.Presentation of Convert Scrap To Prime Materials without hold production.
Presentation of Convert Scrap To Prime Materials without hold production.
 
Astec Australia Hydraulic Breakers & Boom Systems
Astec Australia Hydraulic Breakers & Boom SystemsAstec Australia Hydraulic Breakers & Boom Systems
Astec Australia Hydraulic Breakers & Boom Systems
 
FM 753
FM 753FM 753
FM 753
 
20151021 CAMELEON 5AXIS
20151021 CAMELEON 5AXIS20151021 CAMELEON 5AXIS
20151021 CAMELEON 5AXIS
 
Latest catalogue of Toughcover Tent and Structure
Latest catalogue of Toughcover Tent and StructureLatest catalogue of Toughcover Tent and Structure
Latest catalogue of Toughcover Tent and Structure
 
Thomson BSA Lead and Ball Screws
Thomson BSA Lead and Ball ScrewsThomson BSA Lead and Ball Screws
Thomson BSA Lead and Ball Screws
 

Mehr von Rafi Tchopourian

Engineering and Product Solutions
Engineering and Product SolutionsEngineering and Product Solutions
Engineering and Product Solutions
Rafi Tchopourian
 

Mehr von Rafi Tchopourian (18)

Coates Engineering Solutions Capability
Coates Engineering Solutions Capability Coates Engineering Solutions Capability
Coates Engineering Solutions Capability
 
Coates Engineering Solutions
Coates Engineering Solutions Coates Engineering Solutions
Coates Engineering Solutions
 
Coates Engineering Solutions
Coates Engineering Solutions Coates Engineering Solutions
Coates Engineering Solutions
 
Coates
Coates Coates
Coates
 
Coates Engineering Solutions
Coates Engineering Solutions Coates Engineering Solutions
Coates Engineering Solutions
 
Coates Engineering Solutions
Coates Engineering Solutions Coates Engineering Solutions
Coates Engineering Solutions
 
Coates Hire Engineering Solutions - Hydraulic Shoring Solutions
Coates Hire Engineering Solutions - Hydraulic Shoring SolutionsCoates Hire Engineering Solutions - Hydraulic Shoring Solutions
Coates Hire Engineering Solutions - Hydraulic Shoring Solutions
 
Coates Hire Engineering Solutions - Temporary Works
Coates Hire Engineering Solutions - Temporary Works Coates Hire Engineering Solutions - Temporary Works
Coates Hire Engineering Solutions - Temporary Works
 
Coates Hire Case Study - Billbergia Wentworth
Coates Hire Case Study - Billbergia WentworthCoates Hire Case Study - Billbergia Wentworth
Coates Hire Case Study - Billbergia Wentworth
 
Coates Hire - Case Study
Coates Hire - Case Study Coates Hire - Case Study
Coates Hire - Case Study
 
Coates Hire - Case Study
Coates Hire - Case Study Coates Hire - Case Study
Coates Hire - Case Study
 
Coates Hire Engineering and Product Solutions
Coates Hire Engineering and Product SolutionsCoates Hire Engineering and Product Solutions
Coates Hire Engineering and Product Solutions
 
Coates Hire - Water Treatment Engineering Solutions
Coates Hire - Water Treatment Engineering Solutions Coates Hire - Water Treatment Engineering Solutions
Coates Hire - Water Treatment Engineering Solutions
 
Coates Hire - Engineering and Product Solutions
Coates Hire - Engineering and Product SolutionsCoates Hire - Engineering and Product Solutions
Coates Hire - Engineering and Product Solutions
 
Engineering and Product Solutions
Engineering and Product SolutionsEngineering and Product Solutions
Engineering and Product Solutions
 
Engineering and Product Solutions
Engineering and Product SolutionsEngineering and Product Solutions
Engineering and Product Solutions
 
Coates Hire - Engineering and Product Solutions
Coates Hire - Engineering and Product SolutionsCoates Hire - Engineering and Product Solutions
Coates Hire - Engineering and Product Solutions
 
Coates Hire - Engineering and Product Solutions
Coates Hire - Engineering and Product SolutionsCoates Hire - Engineering and Product Solutions
Coates Hire - Engineering and Product Solutions
 

KĂĽrzlich hochgeladen

1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
AldoGarca30
 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power Play
Epec Engineered Technologies
 
DeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakesDeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakes
MayuraD1
 
"Lesotho Leaps Forward: A Chronicle of Transformative Developments"
"Lesotho Leaps Forward: A Chronicle of Transformative Developments""Lesotho Leaps Forward: A Chronicle of Transformative Developments"
"Lesotho Leaps Forward: A Chronicle of Transformative Developments"
mphochane1998
 
Integrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - NeometrixIntegrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - Neometrix
Neometrix_Engineering_Pvt_Ltd
 
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
9953056974 Low Rate Call Girls In Saket, Delhi NCR
 
Hospital management system project report.pdf
Hospital management system project report.pdfHospital management system project report.pdf
Hospital management system project report.pdf
Kamal Acharya
 

KĂĽrzlich hochgeladen (20)

Online food ordering system project report.pdf
Online food ordering system project report.pdfOnline food ordering system project report.pdf
Online food ordering system project report.pdf
 
Engineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planesEngineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planes
 
PE 459 LECTURE 2- natural gas basic concepts and properties
PE 459 LECTURE 2- natural gas basic concepts and propertiesPE 459 LECTURE 2- natural gas basic concepts and properties
PE 459 LECTURE 2- natural gas basic concepts and properties
 
kiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal loadkiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal load
 
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
 
Unleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leapUnleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leap
 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power Play
 
DeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakesDeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakes
 
School management system project Report.pdf
School management system project Report.pdfSchool management system project Report.pdf
School management system project Report.pdf
 
"Lesotho Leaps Forward: A Chronicle of Transformative Developments"
"Lesotho Leaps Forward: A Chronicle of Transformative Developments""Lesotho Leaps Forward: A Chronicle of Transformative Developments"
"Lesotho Leaps Forward: A Chronicle of Transformative Developments"
 
Integrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - NeometrixIntegrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - Neometrix
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.ppt
 
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
 
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
 
Wadi Rum luxhotel lodge Analysis case study.pptx
Wadi Rum luxhotel lodge Analysis case study.pptxWadi Rum luxhotel lodge Analysis case study.pptx
Wadi Rum luxhotel lodge Analysis case study.pptx
 
Computer Lecture 01.pptxIntroduction to Computers
Computer Lecture 01.pptxIntroduction to ComputersComputer Lecture 01.pptxIntroduction to Computers
Computer Lecture 01.pptxIntroduction to Computers
 
Hospital management system project report.pdf
Hospital management system project report.pdfHospital management system project report.pdf
Hospital management system project report.pdf
 
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptxHOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
 
Design For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the startDesign For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the start
 
AIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech studentsAIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech students
 

Coates Hire - Trench Shoring Solutions

  • 2. 2 // TRENCH SHORING SOLUTIONS Contact us: 13 15 52 | TechnicalDesigns@coateshire.com.au At Coates Hire, we offer the highest quality equipment and we equip our customers with the best expertise in the industry. Our experts provide advice on evaluating the risks associated with equipment supply, performance and operation. Our Engineering Services Team offers comprehensive technical support and we can assist in the concept and design of all engineering solutions. All of which ensures that your site is always performing to its full potential. Our unique ability to provide total equipment solutions helps you drive both time and cost efficiencies. We have the expertise to ensure you have everything you need, anytime you need it. So no matter how big or small your project is, you can count on Coates Hire to help make it happen. • Commitment to Safety: We are passionately commited to safety, helping deliver your project on time whilst ensuring you’re meeting duty of care obligations. • 130 Years’ Experience: We have a track record that spans every market sector, helping to deliver successful projects across a wide range of industries • Project Support: Over 600 branch managers, field sales and product specialists are committed to providing complete solutions to your specific project needs. • Industry Leading Customer Service: At Coates Hire we take customer service seriously and ensure we are continually improving your experience. • Engineering and Technical: Our dedicated team of experts can provide technical solution, design, certification and installation services for temporary works requirements. • R&D Capabilities: Our research, development & innovation arm constantly strives to find new and better solutions, systems and equipment for our customers. OUR EXPERTISE:
  • 3. // 3 TRENCH SHORING SOLUTIONS Aluminium Vertishore Ideal for trench excavations in cohesive soils (clay), Vertishores are a rapidly deployed solution used to stabilise the walls of an excavated trench to allow safe access. Vertishores are light enough to be installed by manual handling and can be used for a range of different trench depths & widths. Perfect for confined sites with limited access to heavy plant and machinery. ALUMINIUM VERTISHORE SPECIFICATIONS V450- 900 V450- 1400 V1050- 900 V1050- 1400 V1500- 900 V1500- 1400 V2100- 900 V2100- 1400 V2400- 900 V2400- 1400 Length of rail (mm) 450 450 1070 1070 1500 1500 2130 2130 2440 2440 Width of rail (mm) 209 204 204 204 204 204 204 204 204 204 No. cylinders - 1 1 2 2 2 2 2 2 2 2 Min. trench width (mm) 560 865 560 865 560 865 560 865 560 865 Max. trench width (mm) 1740 2300 1740 2300 1740 2300 1740 2300 1740 2300 Stroke (mm) 340 535 340 535 340 535 340 535 340 535 Max. trench depth (mm) - - 2435 2435 2460 2460 3015 3015 3015 3015 Weight per unit (kg) 11 13 23 28 28 32 32 37 43 53
  • 4. 4 // TRENCH SHORING SOLUTIONS Contact us: 13 15 52 | TechnicalDesigns@coateshire.com.au Aluminium Shoring Shields provide an extremely light-weight solution for shielding a work zone inside an excavated trench. Lowered into position after excavation has been performed, our range of Aluminium Shoring Shields can be easily lifted and moved using small excavators. This makes them rapid and easy to install, extract, or to move along a trench excavation as construction progresses. A range of panel & strut sizes are available to suit almost any small to medium size trench excavation. STANDARD ALUMINIUM SHORING SHIELDS SPECIFICATIONS Model (L x H) Length Height Pipe Clearance Length Clear Working Width Under Strut Clearance Capacity Box Weight (min internal) L H Lc Bp / Bc hc Stat. Strut Hyd. Strut (kg) Min Max Es Eh (m) (m) (m) (m) (m) (m) (kPa) (kPa) 1.8m x 1.8m 1.83 1.83 1.45 0.40/0.63 2.08/2.31 0.56 53 110 378 2.4m x 1.8m 2.44 1.83 1.90 0.40/0.63 2.08/2.31 0.56 53 67 446 1.8m x 2.4m 1.83 2.44 1.45 0.40/0.63 2.08/2.31 0.56 53 81 426 2.4m x 2.4m 2.44 2.44 1.90 0.40/0.63 2.08/2.31 0.56 53 67 505 L B bp hc Lc H tpl bc Aluminium Shield Dimension Diagram Aluminium Shoring Shield Aluminium Shoring Shields Dimension Diagram
  • 5. // 5 TRENCH SHORING SOLUTIONS Aluminium Shoring Shield SMOOTH WALL ALUMINIUM SHORING SHIELD SPECIFICATIONS Model (L x H) Length Height Pipe Clearance Length Clear Working Width Under Strut Clearance Capacity Box Weight (min internal) L H Lc Bp / Bc hc E (kg)Min Max (m) (m) (m) (m) (m) (m) (kPa) 1.8m x 1.8m 1.83 1.83 1.30 0.40/0.63 2.08/2.31 0.81 105 430 2.4m x 1.8m 2.44 1.83 1.90 0.40/0.63 2.08/2.31 0.81 79 543 1.5m x 2.4m 1.52 2.44 0.99 0.40/0.63 2.08/2.31 1.19 90 454 1.8m x 2.4m 1.83 2.44 1.30 0.40/0.63 2.08/2.31 1.19 80 512 2.4m x 2.4m 2.44 2.44 1.90 0.40/0.63 2.08/2.31 1.19 60 629 3.6m x 2.4m 3.66 2.44 3.12 0.35/0.63 2.03/2.31 1.19 29 859 L B bp hc Lc H tpl bc Aluminium Shield Dimension DiagramAluminium Shoring Shield Dimension Diagram
  • 6. 6 // TRENCH SHORING SOLUTIONS Contact us: 13 15 52 | TechnicalDesigns@coateshire.com.au SUPER ALUMINIUM SHIELD – HIGH CLEARANCE CONFIGURATION Model Length Total Pipe Clearence Length Height Clear Working Width Understrut Clearance Capacity Panel Thickness Box Weight (min internal) L Lc H bc hc E tpl Min Max (m) (m) (m) (m) (m) (m) (kPa) (mm) (kg) 4.5m Lower Only 4.5 4.0 2.3 1.48 4.48 2.2 42 150 3292 4.5m Lower + Upper 4.5 4.0 4.0 1.48 4.48 2.2 42 150 4736 7.3m Lower Only 7.3 6.8 2.3 1.48 4.48 2.2 36 180 4268 7.3m Lower + Upper 7.3 6.8 4.0 1.48 4.48 2.2 36 180 6612 Shield Dimension Diagram (High Clearance configration) L B bc tpl H hc Lc Super Aluminium Shoring Shield The ultimate aluminium shoring shield. The Super Aluminium Shoring Shield combines the light-weight advantages of aluminium construction, with a design engineered for strength and size. This produces a shoring shield that allows you to take your excavation longer, wider & deeper, while still using standard size plant and machinery typically available on a construction site. The Super Aluminium Shoring Shield is ideal for large trenching and pit applications where productivity is critical. SUPER ALUMINIUM SHIELD – STANDARD CONFIGURATION (REFER OVER LEAF FOR IMAGE) Model Length Total Pipe Clearance Length Height Clear Working Width Understrut Clearance Capacity Panel Thickness Box Weight (min internal) L Lc H bc hc E tpl Min Max (m) (m) (m) (m) (m) (m) (kPa) (mm) (kg) 4.5m Lower 4.5 4.0 2.3 1.0 4.0 1.4 42 150 2352 4.5m Upper 4.5 4.0 1.7 1.0 4.0 - 42 150 2064 7.3m Lower 7.3 6.8 2.3 1.0 4.0 1.4 36 180 3400 7.3m Upper 7.3 6.8 1.7 1.0 4.0 - 36 180 2892 Shield Dimension Diagram (Standard Configuration) HH L B hc bc tpl Lc Shield Dimension Diagram (Standard Configuration) Shield Dimension Diagram (High Clearance Configuration)
  • 7. // 7 TRENCH SHORING SOLUTIONS Series 100 Light Shield SERIES 100 LIGHT SHIELD Model Length Total Pipe Clearence Length Height Clear Working Width Understrut Clearance Capacity Panel Thickness Box Weight (min internal) L Lc H bc hc E tpl Min Max (m) (m) (m) (m) (m) (m) (kPa) (mm) (kg) LOWER SHIELD 2.0m x 1.6m 2.0 1.63 1.6 0.6 4.0 1.0 48 60 670 2.0m x 2.0m 2.0 1.63 2.0 0.6 4.0 1.2 48 60 790 2.0m x 2.4m 2.0 1.63 2.4 0.6 4.0 1.2 48 60 900 2.5m x1.6m 2.5 2.13 1.6 0.6 4.0 1.0 38 60 760 2.5m x 2.0m 2.5 2.13 2.0 0.6 4.0 1.2 38 60 890 2.5m x 2.4m 2.5 2.13 2.4 0.6 4.0 1.2 38 60 1020 3.0m x 1.6m 3.0 2.63 1.6 0.6 4.0 1.0 32 60 850 3.0m x 2.0m 3.0 2.63 2.0 0.6 4.0 1.2 32 60 990 3.0m x 2.4m 3.0 2.63 2.4 0.6 4.0 1.2 32 60 1140 UPPER SHIELD 2.0m x 1.0m 2.0 1.63 1.0 0.6 4.0 - 48 60 500 2.5m x 1.0m 2.5 2.13 1.0 0.6 4.0 - 38 60 560 3.0m x 1.0m 3.0 2.63 1.0 0.6 4.0 - 32 60 620 Series 100 Shield Dimension Diagram L H bc H H hc tpl Lc The Series 100 Light Shield is ideal for small to medium pit & trenching excavations where there is limited access to heavy plant & machinery on site. This efficiently designed shield achieves an excellent pressure capacity rating, while still keeping the assembled shield weight to a minimum. In addition to this, its steel construction and simple design produces an extremely robust and versatile shoring solution. Series 100 Shield Dimension Diagram
  • 8. 8 // TRENCH SHORING SOLUTIONS Contact us: 13 15 52 | TechnicalDesigns@coateshire.com.au Manhole Shoring Box SERIES 600 MANHOLE SHORING BOX Model Length Total Pipe Clearence Length Height Clear Working Width Understrut Clearance Capacity Panel Thickness Box Weight (min internal) L Lc H bc hc E tpl Min Max (m) (m) (m) (m) (m) (m) (kPa) (mm) (kg) 2.5m Lower 2.5 2.1 2.5 1.5 6.8 1.53 50.1 107.0 2356 2.5m Upper 2.5 2.1 1.5 1.5 6.8 - 50.1 107.0 1623 3.0m Lower 3.0 2.6 2.5 1.5 6.8 1.53 41.8 107.0 2737 3.0m Upper 3.0 2.6 1.5 1.5 6.8 - 41.8 107.0 1987 M41 MANHOLE SHORING BOX (WA & NT ONLY) Model Length Total Pipe Clearence Length Height Clear Working Width Understrut Clearance Capacity Panel Thickness Box Weight (min internal) L Lc H bc hc E tpl Min Max (m) (m) (m) (m) (m) (m) (kPa) (mm) (kg) 2.6m Lower 2.6 2.2 2.5 1.6 5.0 1.50 41.0 108.0 3140 2.6m Upper 2.6 2.2 1.5 1.6 5.0 - 41.0 108.0 1970 3.0m Lower 3.0 2.6 2.5 1.6 5.0 1.50 41.0 108.0 3530 3.0m Upper 3.0 2.6 1.5 1.6 5.0 - 41.0 108.0 2170 Manhole boxes are ideal for construction of manholes and chambers along a linear excavation such as a pipe installation. Our range of manhole boxes are designed to be flexible, robust, and suit most typical manhole construction sizes. Manhole Box Dimension Diagram LB bc tpl Lc HH hc Manhole Box Dimension Diagram
  • 9. // 9 TRENCH SHORING SOLUTIONS Series 600 Standard Box SERIES 600 STANDARD SHORING BOX– STANDARD CONFIGURATION Model Length Total Pipe Clearence Length Height Clear Working Width Understrut Clearance Capacity Panel Thickness Box Weight (min internal) L Lc H bc hc E tpl Min Max (m) (m) (m) (m) (m) (m) (kPa) (mm) (kg) 3.0m Lower 3.0 2.6 2.4 0.7 6.0 1.53 53.5 107.0 2022 3.0m Upper 3.0 2.6 1.4 0.7 6.0 - 53.5 107.0 1236 3.5m Lower 3.5 3.1 2.4 0.7 6.0 1.53 48.9 107.0 2150 3.5m Upper 3.5 3.1 1.4 0.7 6.0 - 48.9 107.0 1350 4.0m Lower 4.0 3.6 2.4 0.7 6.0 1.53 40.1 107.0 2572 4.0m Upper 4.0 3.6 1.4 0.7 6.0 - 40.1 107.0 1586 4.0m HD Lower 4.0 3.6 2.5 0.7 6.0 1.53 70.0 127.0 3012 4.0m HD Upper 4.0 3.6 1.4 0.7 6.0 - 70.0 127.0 1806 5.0m Lower 5.0 4.6 2.4 0.7 6.0 1.53 38.0 127.0 3290 5.0m Upper 5.0 4.6 1.4 0.7 6.0 - 38.0 127.0 2136 6.0m Lower 6.0 5.6 2.4 0.7 6.0 1.53 27.6 127.0 4172 6.0m Upper 6.0 5.6 1.4 0.7 6.0 - 27.6 127.0 3086 6.0m HD Lower 6.0 5.6 2.4 0.7 6.0 1.53 40.0 130.0 4432 6.0m HD Upper 6.0 5.6 1.4 0.7 6.0 - 40.0 130.0 2786 The Series 600 Shoring Box range provides a shoring solution for almost any medium to large sized pit or trench excavation. With an extensive range of high capacity panels and struts, the Series 600 Box can be assembled to a vast array of different sizes to suit your needs. This system is designed to be high capacity and extremely robust enabling it to stand up to the most challenging of site conditions. It can be installed as a traditional shoring shield, or using the “dig & push” method which is ideal for installation in weak or unstable ground. Series 600 Standard Box Dimention Diagram-Standard Configration bc HH Lc tpl L B hc Series 600 Standard Box Dimension Diagram (Standard Configuration)
  • 10. 10 //TRENCH SHORING SOLUTIONS Contact us: 13 15 52 | TechnicalDesigns@coateshire.com.au Series 600 Standard Box SERIES 600 STANDARD SHORING BOX – HIGH CLEARANCE CONFIGURATION (LOWER + UPPER) Model Length Total Pipe Clearence Length Height Clear Working Width Understrut Clearance Capacity Panel Thickness Box Weight (min internal) L Lc H bc hc E tpl Min Max (m) (m) (m) (m) (m) (m) (kPa) (mm) (kg) 3.0m 3.0 2.6 3.7 1.03 6.33 2.3 49.9 107.0 4944 3.5m 3.5 3.1 3.7 1.03 6.33 2.3 42.8 107.0 5396 4.0m 4.0 3.6 3.7 1.03 6.33 2.3 37.4 107.0 5844 5.0m 5.0 4.6 3.7 1.03 6.33 2.3 29.9 127.0 7112 6.0m 6.0 5.6 3.7 1.03 6.33 2.3 24.9 127.0 8944 To further increase the versatility of the Series 600 Box, a High Clearance option is available. This provides all of the features & benefits of the Standard Configuration, with a significantly increased clearance under the lowest strut. Ideal for installation of large pipes & culverts. Series 600 Standard Box Dimension Diagram-High Clearance Configration L B bc tpl hc H Lc Series 600 Standard Box Dimension Diagram (High Clearance Configuration)
  • 11. // 11 TRENCH SHORING SOLUTIONS M41 Standard Box (WA & NT Only) M41 STANDARD SHORING BOX – STANDARD CONFIGURATION Model Length Total Pipe Clearence Length Height Clear Working Width Understrut Clearance Capacity Panel Thickness Box Weight (min internal) L Lc H bc hc E tpl Min Max (m) (m) (m) (m) (m) (m) (kPa) (mm) (kg) 3.6m Lower 3.6 3.34 2.5 0.6 4.0 1.50 41.0 108.0 2792 3.6m Upper 3.6 3.34 1.5 0.6 4.0 - 41.0 108.0 1796 4.0m Lower 4.0 3.74 2.5 0.6 4.0 1.50 41.0 108.0 3142 4.0m Upper 4.0 3.74 1.5 0.6 4.0 - 41.0 108.0 2046 M41 STANDARD SHORING BOX – HIGH CLEARANCE CONFIGURATION (LOWER + UPPER) Model Length Total Pipe Clearence Length Height Clear Working Width Understrut Clearance Capacity Panel Thickness Box Weight (min internal) L Lc H bc hc E tpl Min Max (m) (m) (m) (m) (m) (m) (kPa) (mm) (kg) 3.6m 3.6 3.34 4.0 1.10 4.75 2.6 41.0 108.0 6060 4.0m 4.0 3.74 4.0 1.10 4.75 2.6 41.0 108.0 6660 The M41 Standard Box range is designed to be high capacity and extremely robust, enabling it to stand up to the most challenging of site conditions. It can be installed as a traditional shoring shield, or using the “dig & push” method which is ideal for installation in weak or unstable ground. To further increase the versatility of the M41 Standard Box , a High Clearance option is available. This provides all of the features & benefits of the Standard Configuration, with a significantly increased clearance under the lowest strut. Ideal for installation of large pipes & culverts. M41 Standard Box Dimension Diagram-Standard Configuration H H L B bc tpl hc Lc M41 Standard Box Dimension Diagram-High Clearance Configuration LB bc H hc Lc tpl M41 Standard Box Dimension Diagram (Standard Configuration) M41 Standard Box Dimension Diagram (High Clearance Configuration)
  • 12. 12 //TRENCH SHORING SOLUTIONS Contact us: 13 15 52 | TechnicalDesigns@coateshire.com.au Rolling Strut Box SERIES 600 ROLLING STRUT BOX Model Length Total Pipe Clearence Length Height Clear Working Width Understrut Clearance Panel Capacity* Panel Thickness Box Weight (min internal) L Lc H bc hc E tpl Min Max (m) (m) (m) (m) (m) (m) (kPa) (mm) (kg) 3.0m (SSR Strut) 3.0 2.3 3.7 2.69 > 6.0 1.2 - 2.5 53.5 107.0 5760 3.0m (DSR Strut) 1.9 - 1.5 6480 3.5m (SSR Strut) 3.5 2.8 1.2 - 2.5 48.9 107.0 6212 3.5m (DSR Strut) 1.9 - 1.5 6932 4.0m (SSR Strut) 4.0 3.3 1.2 - 2.5 40.1 107.0 6660 4.0m (DSR Strut) 1.9 - 1.5 7380 4.0m HD (SSR Strut) 4.0 3.3 1.2 - 2.5 70.0 127.0 7320 4.0m HD (DSR Strut) 1.9 - 1.5 8040 5.0m (SSR Strut) 5.0 4.3 1.2 - 2.5 38.0 127.0 7928 5.0m (DSR Strut) 1.9 - 1.5 8648 6.0m (SSR Strut) 6.0 5.3 1.2 - 2.5 27.6 127.0 9760 6.0m (DSR Strut) 1.9 - 1.5 10480 6.0m HD (SSR Strut) 6.0 5.3 1.2 - 2.5 40.0 130.0 9720 6.0m HD (DSR Strut) 1.9 - 1.5 10440 Rolling Strut Boxes are ideal for applications where extremely wide excavation dimensions are required. The bolt-together strut assembly means that there is no fixed limit to strut length, subject to a free-of-charge design review by Coates Hire’s team of in-house engineers. Added to this the flexibility of the rolling strut allows variable strut positioning to enable the user to avoid obstructions within the excava-tion zone during excavation & construction. *Capacity subject to confirmation by a suitably qualified engineer. “SSR” = Single Slide Rail (ref. following section) “DSR” = Double Slide Rail (ref. following section) Series 600 Rolling Strut Box-Std. Configuration L B bc tpl hc H Lc Series 600 Rolling Strut Box (Standard Configuration)
  • 13. // 13 TRENCH SHORING SOLUTIONS Rolling Strut Box 7.4M LARGE ROLLING STRUT BOX Model Length Total Pipe Clearence Length Height Clear Working Width Understrut Clearance Panel Capacity Panel Thickness Box Weight (min internal) L Lc H bc hc E tpl Min Max (m) (m) (m) (m) (m) (m) (kPa) (mm) (kg) Lower 7.4 6.4 2.4 1.35 > 6.0 1.56 57.0 170.0 8840 Upper 1.6 1.35 - 57.0 170.0 6940 High Clear 4.0 1.85 2.50 53.0 170.0 17220 7.4 Large Rolling Strut Box-High Clearance Configuration L B bc tpl H hc Lc 7.4 Large Rolling Strut Box (High Clearence Configuration)
  • 14. 14 //TRENCH SHORING SOLUTIONS Contact us: 13 15 52 | TechnicalDesigns@coateshire.com.au Slide Rail Shoring—Trench Configuration SINGLE SLIDE RAIL* Panel Type (Length) Module Length Pipe Clearence Length Height Clear Working Width Understrut Clearance Panel Capacity Panel Thickness Ls Lc H bc hc E tpl Min Max (m) (m) (m) (m) (m) (m) (kPa) (mm) 2.0m 2.27 1.84 2.4 - 3.8 1.25 >6.0^ 0.99 - 2.31 158.0 107.0 3.0m 3.27 2.84 148.0 130.0 4.0m 4.27 3.84 66.0 107.0 4.0m HD 4.27 3.84 82.0 130.0 6.0m 6.27 5.84 60.0 150.0 7.4m 7.67 7.20 57.0 180.0 DOUBLE SLIDE RAIL* Panel Type (Length) Module Length Pipe Clearence Length Height Clear Working Width Understrut Clearance Panel Capacity Panel Thickness Ls Lc H bc hc E tpl Min Max (m) (m) (m) (m) (m) (m) (kPa) (mm) 2.0m 2.27 1.84 2.4 - 9.0 1.25 >6.0^ 1.42—3.42 158.0 107.0 3.0m 3.27 2.84 148.0 130.0 4.0m 4.27 3.84 66.0 107.0 4.0m HD 4.27 3.84 82.0 130.0 6.0m 6.27 5.84 60.0 150.0 7.4m 7.67 7.20 57.0 180.0 Slide Rail is the ultimate in steel shoring solutions. It is the most robust & flexible shoring method for large excavations on the market, and allows you to take your excavations longer, wider & deeper than with any other product. It offers unrivalled pressure rating, allowing excavation depths of up to 9.0m in most conditions, and offers the largest under-strut clearance of any product on the market. *All applications of Slide Rail should be assessed by a suitably qualified engineer. ^Additional strut lengths are achievable depending on the application. Slide Rail Dimension Diagram-Trench Configuration L B tpl bc H Lc hc Slide Rail Dimension Diagram-Trench Configuration
  • 15. // 15 TRENCH SHORING SOLUTIONS Slide Rail Shoring—Pit Shoring Configuration* SLIDE RAIL SHORING—PIT SHORING CONFIGURATION* Pit Size (Panel Length x Panel Length) Module Length Internal Clearance Length Module Width Internal Clearance Width Height (Single Slide Rail Configuration) Height (Single Slide Rail Configuration) Minimum Panel Capacity Ls Lc B bc H H E (m) (m) (m) (m) Min Max Min Max (kPa) (m) (m) (m) (m) 2.0m x 2.0m 2.5 2.2 2.5 2.2 2.4 3.8 2.4 9.0 REFER SLIDE RAIL SHORING TRENCH CONFIG. SECTION 2.0m x 3.0m 2.5 2.2 3.5 3.2 2.0m x 4.0m 2.5 2.2 4.5 4.2 2.0m x 6.0m 2.5 2.2 6.5 6.2 2.0m x 7.4m 2.5 2.2 8.3 7.3 3.0m x 3.0m 3.5 3.2 3.5 3.2 3.0m x 4.0m 3.5 3.2 4.5 4.2 3.0m x 6.0m 3.5 3.2 6.5 6.2 3.0m x 7.4m 3.5 3.2 8.3 7.3 4.0m x 4.0m 4.5 4.2 4.5 4.2 4.0m x 6.0m 4.5 4.2 6.5 6.2 4.0m x 7.4m 4.5 4.2 8.3 7.3 6.0m x 6.0m 6.5 6.2 6.5 6.2 6.0m x 7.4m 6.5 6.2 8.3 7.3 7.4m x 7.4m 8.3 7.3 8.3 7.3 To add to Slide Rail’s extensive range of capabilities, the addition of 90 degree corner posts allows for fully enclosed pit excavations to be achieved. Using the corner posts with the extensive range of panels, and their extremely high pressure rating, almost any size pit excava-tion can be shored. Slide Rail Diamension Diagram-Pit Shoring Configration L B H bc Lc *All applications of Slide Rail should be assessed by a suitably qualified engineer. Slide Rail Dimension Diagram-Pit Shoring Configuration
  • 16. 16 //TRENCH SHORING SOLUTIONS Contact us: 13 15 52 | TechnicalDesigns@coateshire.com.au Safety • Safety is embodied in everything we do and we work closely with our customers to create the safest working environment possible • Our complete range of excavation safety products are NATA tested & accredited and compliant to Australian Standards EDGE PROTECTION Coates Hire edge protection hand rails are compatible with our entire fleet of aluminium and steel shoring panels. The adjustable hand rail unit provides a flexible and rapid solution for edge protection around excavations of any size. The hand rail units are light- weight and in full compliance with AS1657. RESCUE SYSTEMS The Coates Hire davit rescue system provides a fast and easy solution to meeting safety requirements associated with working in deep excavations. The simple design clamps onto the side of any Coates Hire shoring panel, making installation fast & user friendly. All davit systems are supplied as a comprehensive kit in a secure, lockable storage case. EDGE PROTECTION Model Length Height Weight (m) (m) (kg) 3m 3.0 1.0 19.8 4m 4.0 1.0 21.6
  • 17. // 17 TRENCH SHORING SOLUTIONS Safety LADDER ACCESS SYSTEMS & PLATFORMS Means of access and egress into deep excavations can often pose an issue on sites where space is at a premium. To provide a simple and cost effective solution to this challenge, Coates Hire carries a range of temporary access systems which are fast and easy to install, and do not require a specialist contractor.
  • 18. 18 //TRENCH SHORING SOLUTIONS Contact us: 13 15 52 | TechnicalDesigns@coateshire.com.au Engineering & Technical Support EMS 648129FS 648130 OHS 648128 OHS 648127 *Environmental certification (ISO4001) achieved at Head Office and an expanding number of branches. At Coates Hire, we have been providing a wide range of specialist equipment and services for over 130 years. We pride ourselves in providing much more than just our product range. Our aim is to meet our customers’ safety, compliance, productivity, environmental and cost management expectations. Our equipment offering is supported by an in-house Temporary Works Department of highly trained and fully qualified Certifying Engineers, Design Engineers & Drafters, Regional Sales Engineers and Product Specialists. This allows us to provide a level of Engineering & Technical support for your project like no other supplier in the market. KEY CAPABILITIES • Fully qualified National Engineering department with extensive experience in temporary works design & installation • Professionally presented design solutions & drawings using the latest CAD software • Tender support packages for estimators and planning functions including budget costing • Support for site teams to develop best solutions and cost effective design options to keep within timescales and budget expectations • Engineering design sign off and installation sign off provided with equipment hire (CPEng, NER, RPEQ) • Risk Assessments both generic and project-specific • Safety in design • Develop safe and sustainable solutions • Training and coaching of site staff in all products via a range of tool box talks and ongoing support to help keep projects on track and provide safest possible working environment • ISO Accredited for Quality, Environmental, & OHS Management
  • 19. Access Air & Air Accessories Compaction Concrete & Masonry Earthmoving Floor and Cleaning Equipment Generators & Power Distribution Industrial tools & Equipment Ladders & Scaffold Landscaping Lift & Shift Lighting Materials Handling Portable Buildings & Toilets Propping Pumps & Fluid Management Shoring Tools & Equipment Traffic Management Training (RTO) Trucks, Vehicles & Trailers Welding COATES HIRE’S AVAILABLE PRODUCT RANGE: At Coates Hire, you’ll find an unmatched range of equipment, available and ready to hire. We stock Australia’s largest fleet from general hire gear and specialist products, to total site solutions. With the largest branch network in Australia, you are backed by one of the country’s largest delivery networks.
  • 20. WhileCoatesHiremakeseveryefforttosupplytheequipment described and pictured in this brochure, all equipment offered is subject to availability. Should Coates Hire through whatever circumstances need to offer an alternative make or model, customers can be assured that this will be of the same quality as the item shown or displayed in this brochure. All information about equipment in this brochure is to the best of our knowledge correct, but we would urge customers to check all details at the time of hire or enquiry. Coates Hire reserves the right to change information without prior notice. ISSUE1.0