GridPoint offers a new breed of intelligent Energy Management System (EMS)controllers equipped with revenue-grade accurate metering devices to monitor electricity, natural gas, propane, or water consumption. Our patented system transcends traditional energy management systems while having the ability to submeter, interface with alarm security systems, provides information to assist in monitoring facility maintenance services, and much more. The EMS delivers rapid ROI for buildings of 1,500 square feet and above.
Industrial monitoring and control systems using andriod application
GridPoint\’s Energy Management System Intelligent Controllers
1. Efficiency
Solutions
You Can
Count On
ADM-3612 • ADM-1204 • ADM-BASIC
ADMMicro’s Energy Management System intelligent controllers provide powerful
real-time tools that monitor, control, store, and transmit energy consumption
and facility operational data. Once installed, the flexible controllers (ADM-3612,
ADM-1204, and ADM-BASIC) can be reprogrammed to implement various
energy consumption and facility operational strategies for one building or an
entire enterprise. Small-building enterprises can achieve significant savings and
compelling paybacks as facility managers optimize energy usage.
core feaTureS
• Dynamic Demand Limiting and Energy Touch-Screen DiSplay
Optimization algorithms All three controllers are equipped with an integrated
• HVAC thermostat and lighting controller interfaces touch-screen graphical display, which serves as a
• Whole building or component-level load profiling powerful, secure two-way local interface. Entry of
• Ability to handle multiple communications protocols security codes can be required to limit access as
• Open, flexible protocols with dial-in/out or desired. Through this interface, local personnel can:
Ethernet connectivity • Temporarily override or permanently change
lighting schedules, HVAC set points, and other
Individual buildings or an entire enterprise can
facility operational parameters
be integrated and managed on-site or remotely.
• Display detailed data to facilitate maintenance and
Preventive maintenance and equipment thresholds
operational efficiencies
can be set with automatic alerts, so that expensive
• Modify site-specific controller configuration
assets can be proactively serviced before failures occur.
parameters
Industrial-grade, embedded microprocessor designs
combined with customizable firmware allow you to
coMMunicaTion porTS
design your system and energy consumption to best
Each controller contains onboard Ethernet as well as a
meet your needs.
universal socket modem to enable either traditional
ADMMicro controllers can poll various I/O devices, analog phone line or wireless cellular connectivity.
log data and transmit it to other systems using a In addition, each unit features three serial ports:
variety of protocols, including MODBUS/RTU. If two RS-485 and one RS-232. These ports can be
systems are outside of set parameters, the software configured with multiple protocols, such as MODBUS/
will send an alert or alarm to an on-site display or to RTU. And because the ports can operate with different
another location via e-mail. protocols simultaneously, our controllers can act as
protocol converters, interfacing with a wide variety of
This is a total solution for high-efficiency building
third-party meters and devices.
management that can provide a wide range of
monitoring and control, including:
TherMoSTaT anD lighTing
• HVAC systems
conTroller inTerfaceS
• Lighting (interior and exterior)
All three controllers can monitor and control the
• Marquee and store signage
HVAC system through communicating thermostats
• Humidity
and can control interior and exterior lighting through
• Air quality
communicating lighting control panels. They provide
• Emergency lighting systems
smart algorithms for dynamic demand control.
• Duct temperatures
“Setback” programmable schedules may be employed
• Freezer/cooler
to achieve additional energy savings.
• Hot water heaters
• Motion sensors
• Other power-consuming systems
ADMMicro, Inc., 111 Franklin Road SE, Suite 110, Roanoke, VA 24011 • Phone: 866-800-8906 (toll-free)
Phone: 540-527-4600 • Fax: 540-527-4605 • info@admmicro.com •www.admmicro.com
2. extensive onboard Data logging
All three controllers can store large volumes of time-stamped “trend” data
for later retrieval. Stored data can include a wide range of energy and
environmental measurements as well as operational logs. This continuous
and detailed stream of information is essential for all highly efficient and
sustainable management programs.
integrated Multi-circuit electric power Monitoring
The ADM-3612 and ADM-1204 controllers contain patented technology
that provide built-in revenue-grade accurate metering and power
monitoring down to the sub-cycle level. These controllers enable you to
benefit from Dynamic Demand Limiting algorithms, which will manage
aDM-3612 peak kW by means of intelligent and predictive recovery methods. Multiple
inputs allow separate, submetering of individual loads with revenue-
accurate power monitoring. Both the ADM-3612 and the ADM-1204 can
be configured to count pulses, sense contact status, and provide alarm
notification for a variety of input thresholds.
The ADM-3612 and ADM-1204 provide advanced electric
power-monitoring capabilities, including:
• True RMS, four quadrant, multi-circuit ower monitoring
p
• Three voltage inputs for measurement nd one voltage input for
a
auxiliary power
• Measured quantities include:
– Voltage: L-L, L-N
– Current: per circuit
aDM-1204 – Real power (watts) and energy (watt-hours): per phase, polyphase,
or totalized
– Reactive power (VAR) and energy (VAR-hours): per phase, polyphase,
or totalized
– Apparent power (VA): per phase or polyphase
– Power factor: per phase or polyphase
– Frequency
– Total Harmonic Distortion (THD) – voltage and current
• Measurement values available as:
– Instantaneous (real-time)
– Integration (register “dial” readings)
– Historical, time-stamped data logging (load profile) – average value
aDM-BaSic over a configurable data interval (5-minute, 15-minute, etc.)
• Waveform sampling at up to 64 samples per cycle – voltage and current
• ANSI C12.1-2001 revenue accuracy; overall accuracy dependent upon
current sensor selection
3. aDMMicro energy Management System controllers
Applications and Technical Specifications Comparison
applicaTionS aDM-3612 aDM-1204 aDM-BaSic
Multi-circuit polyphase electric power monitoring:
Commercial/industrial submetering 36 circuits 12 circuits NA
Tenant cost allocation 36 circuits 12 circuits NA
Peak demand projection 36 circuits 12 circuits NA
energy management/building automation:
HVAC control (multiple units) ✔ ✔ ✔
HVAC performance monitoring:
• Supply air temperature ✔ ✔ ✔
• Runtime (by stage) ✔ ✔ ✔
• Filter condition (differential pressure) ✔ ✔ Note 1
• Electrical load ✔ ✔ NA
Lighting control ✔ ✔ ✔
Electric demand control ✔ ✔ NA
Building total electric load/utility meter verification ✔ ✔ NA
Occupancy monitoring ✔ ✔ Note 1
Door monitoring ✔ ✔ Note 1
Gas/water monitoring ✔ ✔ Note 1
environmental monitoring:
• Space temperature ✔ ✔ ✔
• Freezer/cooler temperature ✔ ✔ ✔
• Relative humidity ✔ ✔ ✔
• Air quality ✔ ✔ Note 1
• Building pressure ✔ ✔ Note 1
• Light intensity ✔ ✔ ✔
Emergency lighting monitoring, control, ✔ ✔ NA
and automated testing (NFPA 101)
Security system interface ✔ ✔ Note 1
Multi-input pulse counter/totalizer 38 inputs max. 14 inputs max. NA
Note 1: External modules are available to provide this additional capability.
NA = Not Applicable
✔ = Capability is fully supported
4. Technical SpecificaTionS aDM-3612 aDM-1204 aDM-BaSic
Measurement voltage inputs 3 inputs, 120/277 VAC phase 3 inputs, 120/277 VAC phase Not applicable
to neutral, 208/480 VAC phase to neutral, 208/480 VAC phase
to phase to phase
Auxiliary/control power 120 or 240 VAC +/- 20% 120 or 240 VAC +/- 20% 15-28 volts VAC or VDC
voltage requirements
Analog input options: 36 inputs for use with 12 inputs for use with Not applicable
• Current transformer (CT) voltage output CTs: 0.3333 voltage output CTs: 0.3333
inputs for electric power or 0.5000 VAC or 0.5000 VAC
measurements, transformers
available from 5 to 5000
amps in window, split-core,
or rope form factors for
electric power measurements
• General purpose signal 36 inputs configurable for 12 inputs configurable for Not applicable
voltage inputs 0-1 VDC or 4-20 mA inputs 0-1 VDC or 4-20 mA inputs
with dropping resistor with dropping resistor
Digital inputs (dry contacts) 2 optically isolated, plus 36 2 optically isolated, plus 12 Not applicable
using analog inputs using analog inputs
Digital outputs 2 outputs, 30 VDC @ 2 outputs, 30 VDC @ Not applicable
(low voltage/current) 25 mA max. 25 mA max.
Local display 4.75" x 3.5" QVGA graphical 4.75" x 3.5" QVGA graphical 4.75" x 3.5" QVGA graphical
LCD touch screen LCD touch screen LCD touch screen
Onboard telephone modem 56k, dial out, off-hook detection, 56k, dial out, off-hook detection, 56k, dial out, off-hook detection,
RJ-11 RJ-11 RJ-11
TCP/IP Ethernet port 10/100 RJ-45 10/100 RJ-45 10/100 RJ-45
RS-485 ports 1 port, 4-wire w/IDC connector 1 port, 4-wire w/IDC connector 1 port, 4-wire w/screw terminals
1 port, 2-wire w/IDC connector 1 port, 2-wire w/IDC connector 1 port, 2-wire w/screw terminals
(1 port configurable as second RS-232)
RS-232 ports 1 port w/DB-9, 1 port w/IDC 1 port w/DB-9, 1 port w/IDC 1 port w/DB-9, 1 optional port
connector connector w/screw terminals
Onboard, long-term data ~ 72,200 time-stamped trend ~ 72,200 time-stamped trend ~ 72,200 time-stamped trend
storage, nonvolatile data values data values data values
Compliance UL/CUL listed, UL61010C-1, UL/CUL listed, UL61010C-1, UL/CUL listed, UL61010-1,
(E238871), CE (E238871), CE (E238871)
Power measurement accuracy Meets or exceeds ANSI Meets or exceeds ANSI Not applicable
C12.1-2001 C12.1-2001
Power measurement sensing 64 samples/cycle (max.), 64 samples/cycle (max.), Not applicable
true RMS, 4 quadrant true RMS, 4 quadrant
Frequency range 50 – 60 Hz 50 – 60 Hz 50 – 60 Hz
Temperature/humidity range –20C to +70C –20C to +70C –20C to +70C
0 to 95% RH non-condensing 0 to 95% RH non-condensing 0 to 95% RH non-condensing
Enclosure 20.25”x 16.5”x 4.5” steel, 18" x 14" x 4" steel, 8" x 8.5" x 2" aluminum
dust/water resistant, dust/water resistant,
with knockouts: .5", .5" & 1" with knockouts: .5", .5" & 1"
Shipping weight ~ 29 lbs ~ 25 lbs ~ 2 lbs