Sustainable Lifecycle Innovation Management (SLIM) is a simple but effective aprroach to making efficiency central to IT operations and in moving IT from being a cost centre to an centre for Innovation and lean efficiency
2. Software challenges
• 90,000 Employees
• 1 Billion Customers
• 425,000 Partners
Reduce the 3-5% of energy consumed
by software driven devices
Use software to address the larger
challenge
3. Green Computing?
Wikipedia
• The study and practice of using computing
resources efficiently.
• primary objective is to account for the triple
bottom line
– People, planet, profit
• The goals are to
– reduce the use of hazardous materials
– maximize energy efficiency during a product's lifetime
– promote recyclability of defunct products and waste.
6. 1. The Environment
Energy Demands
& Population
Growth
Pollution &
Emissions
Climate
Change
Resource
Destruction
7. Freeform & the Register survey Feb 2008
53% of respondents stated that public relations
and the organisation's image were very likely to
motivate action on environmental issues
2. The Customer
8. Wisdom of the Crowds ...
• Mass collaboration changes every thing*:
– www.glassdoor.com
– www.uservoice.com
– www.getsatisfaction.com
– www.ideastorm.com
– www.guardian.co.uk/environment/series/greenwash
– www.howstuffworks.com/greenwashing.htm
– www.stopgreenwash.org
– www.achievezero.com
– www.greenpeace.org
*Wikinomics
9. 3. The Government
• Cares what its customers say ...
– Climate Change Act
– Carbon Reduction Commitment
– EU Code of Conduct for DCs
10. The Climate Change Act 2008
• Introduced 11/07 & law 28/11/08
• First country to put emission targets into law
– 26% reduction by 2020
– 80% reduction by 2050
– Legally-binding 5-year budgets for greenhouse gas
reduction
• All primary greenhouse gases are included
• Carbon Reduction Commitment
http://www.defra.gov.uk/environment/climatechange/uk/legislation
11. The Carbon Reduction Commitment
• Mandatory cap and trade scheme for 04/10
– Affect approx 5K organisations with
Energy consumption of over 6,000MWh.
– Monitor and report their energy usage.
– Appear on a published league table
– Carbon Allowances around £12/tCO2e.
• An organisation consuming around 8,000MWh
could pay as much as £100,000 per year.
http://www.defra.gov.uk/environment/climatechange/uk/legislation
12. EU Code of Conduct for Data centres
• CoC is a voluntary initiative
– Based on US EnergyStar Data Center
Infrastructure Ratings.
– Develop and promote best practice for DCs
– monthly monitoring of energy usage
• Widely seen as “regulation through the back
door”
– “I view this [CoC] as a wider move towards mandatory
energy reporting for data centre owners and
providers.” - Alec Selvon-Bruce of Hitachi
http://re.jrc.ec.europa.eu/energyefficiency/html/standby_initiative_data centers.htm
13. “Western European electricity consumption [in DCs] for
2007 can be estimated at 56 TWh per year and is
projected to increase to 104 TWh per year by 2020.”
• Is “energy” a purchase criteria for your IT?
• It might be for your car… but IT?
4. The money
http://re.jrc.ec.europa.eu/energyefficiency/html/standby_initiative_data centers.htm
20. Get hold of your bill!
Freeform & the Register survey Feb 2008
“72% of IT organisations don’t see their
energy bills!”
21. Datacentre power consumption
Source: EYP Mission Critical Facilities Inc., New York
IT Equipment,
50%
Cooling, 25%
Air
Movement,
12%
Electricity
Transformer/
UPS, 10%
Lighting, 3%
22. Find the hotspots ...
Back Top
Back Middle
Back Bottom
16 20 24 4 8 12 16
60
65
70
75
80
85
90
Time (24 hours from 2/26/2007 4:00pm)
Front Top
Front Middle
Front Bottom
25. Hot & Cold Aisle Cooling
Source: Lawrence Berkeley National Labs
CRAH = computer room air handler
26. Raise the temperature!
• Many DCs are run for
the comfort of the
operators or hotspots
• In favourable climates
outside air can
work well
too.*
* http://www.intel.com/it/pdf/Reducing_Data_Center_Cost_with_an_Air_Economizer.pdf
29. Server setup Average
watts kWh/year Cost* Kilograms of
CO2*
Standalone IIS7 server × 4 2,000.40 17,535.51 $1,602.75 13,633
One Hyper-V server with 4 IIS7
virtual machines
517.66
(measured) 4,537.81 $414.76 3,528
Potential Savings 1,482.74 12,997.70 $1,187.99 10,105
Standalone IIS7 server × 10 5,001.00 43,838.77 $4,006.86 34,083
One Hyper-V server with 10 IIS7
virtual machines
512.17
(measured) 4,489.68 $410.36 3,491
Potential Savings 4,488.83 39,349.08 $3,596.51 30,592
* See Average Retail Price of Electricity to Ultimate Customers by End-Use Sector, by State (http://www.eia.doe.gov/cneaf/electricity/epm/table5_6_b.html) and
Greenhouse Gas Equivalencies Calculator (http://www.epa.gov/cleanenergy/energy-resources/calculator.html) from the U.S. Environmental Protection Agency.
Source: Ward Ralston and Erik
Virtualisation
30. Virtualisation pitfalls
• VM Sprawl
– Management of VMs is key
• Storage
– VMs are only part of the solution, don’t forget
storage virtualisation too
• IO bottleneck
– Understand IO requirements of VM candidates
– It won’t be the # VMs but amount of IO that
throttles the server
32. Power Usage Efficiency (PUE)
Microsoft Datacentre PUE from
Aug 2004 to Aug 2007
Annual Avg PUE Targets for New
Datacenter Construction
http://blogs.msdn.com/the_power_of_software/
Data Center Efficiency - Beyond PUE and DCiE
33. In Summary ...
• Sustainability is and will be a key factor for IT
– Environment
– Customers
– Government
– Cost
• Consider Green IT in terms of
– Sustainability
– Efficiency
– Agility
– Innovation
34. SLIM is ...
• Looking at sustainability across the lifecycle
• Gradual quantifiable success
• Continuous improvement
• Moving from cost & control to
growth and innovation
• Developing a culture of sustainable innovation
• And don’t forget ...
37. Resources
• White Papers
– 4 reasons to go green
• http://msdn.microsoft.com/en-gb/dd722718.aspx
– Processor Power Management in Windows Vista and Windows Server 2008
• http://www.microsoft.com/whdc/system/pnppwr/powermgmt/ProcPowerMgmt.mspx
– How to Enable Processor Power Management in Windows Server 2003
• http://www.microsoft.com/whdc/system/pnppwr/powermgmt/w2k3_ProcPower.mspx
– Windows Vista Energy Conservation
• http://www.microsoft.com/whdc/system/pnppwr/powermgmt/VistaEnergyConserv.mspx
– Best practices for datacenters
• http://download.microsoft.com/download/a/7/b/a7b72ab1-ca17-4589-923a-83b0ff57be6d/Energy-
Efficiency-Best-Practices-in-Microsoft-Data-Center-Operations-CeBIT.doc
• http://blogs.technet.com/msdatacenters/archive/2009/04/20/microsoft-s-top-10-business-practices-
for-environmentally-sustainable-data-centers-celebrating-earth-day.aspx
• What Microsoft is doing
– http://www.microsoft.com/environment
• The Green Grid organization
– http://www.thegreengrid.org