This document contains architectural plans and details for a multi-level building including a basement, ground floor, and three upper floors, as well as a roof plan. It includes floor plans for each level with dimensions and notes. It also contains details for various building components like the curtain wall facade, stairs, columns, roof structure, suspended ceiling, raised access floor, and exterior cladding. The plans and details are accompanied by notes specifying materials and compliance with building codes.
Puneville - 2, 3, 4BHK Ultra luxurious flat in an elite township project in p...
MARK THORNTON ISO CORNER SECTION DETAIL
1. DNUP
UP
DN
DN
DN
87654321
121110987654321
DN
65432
1413121110987
1918171615
8765432
17161514131211109
321
321
321
GROUND LEVEL
0
GROUND FLOOR PLAN
400
BASEMENT FLOOR PLAN
-3000
FIRST FLOOR PLAN
4500
SECOND FLOOR PLAN
7695
THIRD FLOOR PLAN
11500
ROOF PLAN
15000
BC
TOP OF ROOF ACCESS
17500
NAME: MARK THORNTON
CLASS: DESIGN AND DETAIL 3
DATE:
DRAWING NO.SCALE:
CHECKED BY:
ARCHITECTURAL TECHNOLOGY
YEAR 3
1 : 100
KEY SECTION
CURTAIN WALL
CURTAIN WALL CONSTRUCTED FROM
50mm X 150mm ALUMINIUM MULLIONS
@ 2000mm C/C WITH TRIPLE GLAZED
GLASS PANELS WITH ARGON GAS
IN CENTRE TO GET DESIRED U VALUE
TO COMPLY WITH TGD PART L
600mm SPANDREL PANELS FIXED AT
FLOOR INTERVALS WITH LAMATHERM
FIRE STOP 1000mm X 2000mm WINDOW
OPENINGS LOCATED AT EACH FLOOR
TO PROVIDE VENTILATION
AMBULANT DISABLES STAIRS
PRE CAST CONCRETE STAIRS
1500mm WIDE WITH 300mm
GOING AND 180mm RISERS
STAIRS FIXED TO STRUCTURAL
CONCRETE WALL WITH STEEL
AND GLASS HANDRAIL BOLTED
TO STAIRS STAIRS TO COMPLY
WITH TGD M
COLUMNS
400mm x 400mm STEEL
REINFORCED CAST -INSITU
CONCRETE COLUMNS AS PER
STRUCTURAL ENGINEERS
SPECIFICATIONS
ROOF AND PARAPET
300MM CAST IN-SITU CONCRETE
WITH DPM LAID UNDER 100 MM
TAPERED RIGID BOARD INSULATION
WITH 2 LAYERS OF TORCHED ON BITUM
2 70MM C SECTION CHANNELS WITH
400MM STEEL SHEETS FIXED EITHER SIDE
FOR PARAPET WITH 100MMRIGID BOARD
INSULATION WRAPPEDAROUND PARAPET
DPM TO BE WRAPPED INSULATION AND
OVERLAP 100MM WITH INSULATION ON
THE CONCRETE WALL PARAPET FINISHED
WITH ALUMINIUM CAPPING
SUSPENDED CEILING
SUSPENDED CEILING FIXED TO
UNDERSIDE OF 300MM REINFORCED
CAST IN SITU CONCRETE SLAB
WITH WIRES 600X600MM CEILING
TILES PLACED INTO GRID
RAISED ACCESS FLOOR
192MM PEDESTALS FIXED TO
300MM REINFORCED WITH
600X600X38MM PANELS FIXED
PEDESTALS TO ALLOW ACCESS
CLADDING
100MM RIGID BOARD INSULATION
FOR DESIRED U-VALUE TO COMPLY
WITH TGD L STEEL BRACKETS FIXED
TO CONCRETE WALL AND VERTICAL RAILS
FIXED TO BRACKETS AND HORIZONTAL
KINGSPAN BENCHMARK CARRIER
RAIL FIXED TO VERTICAL RAILS 980MM
AND 480MM LONG FIBRE CEMENT
CLADDING FIXED TO CARRIER RAIL WITH
BENCHMARK BRACKET
NTS
10/03/2014
ISO Building Corner
Section Detail