SlideShare ist ein Scribd-Unternehmen logo
1 von 19
Downloaden Sie, um offline zu lesen
MAGNETICVIVACITY
MAGGIESTEVENS//INDS302//WINTER2015
TABLEOFCONTENTS lighting concept
light map
three dimensional light map
reflected ceiling plan
electrical lighting plan
zonal diagram
section
elevations
specifications
lpd calculation
perspectives
4
5
6
1
3
7
8
9
10
11
12
15
highlighted furniture plan
lighting concept
The basic need of perfectly schemed general
lighting with a hint of excitement and
adventure that draws the user to the space.
Being a conference room, the lighting needs
to be adequate for presentation, pin ups,
showcasing and assembly. It `cannot be too
bright or overbearing because glass is a
major percentage of this design. It will be
contained and direct without being too
glaring and effecting other areas. Marimekko
is a classic company in need of a innovative
design to reveal the brilliance of the
company.
timeless . magnetic . vivacious
1
highlighted furniture plan scale 3/32” // 1’-0”
scale 1/4” // 1’-0”
scale 1/4” // 1’-0”
N
N
N
3
light map
= daylight
= artificial light
legend
scale 1/4” // 1’-0”
1
2
3
4
5
6
7
1
2
3
4
5
6
7
= direct and moveable task
lighting to give light to the
wall mounted pinup boards
= accent lighting meant to
highlight the entrance to
the room and draw people in
= light to help with
wayfinding; to draw people
into the room
= lighting to give luminance to the
conference table and the
people working at it
= accent lighting and also
some general task lighting
for the lounge area
= natural daylight coming in
from the East
= generous amount of
natural daylight coming through
the glass wall of conference
room // adjacent to the open
N
8
8 = general lighting
4
three dimensional light map
5
reflected ceiling plan
scale 1/4” // 1’-0”
N
6
scale 1/4” // 1’-0”
N
electrical lighting plan
7
zonal diagram
legend
= task lighting
= general lighting
= accent lighting
= general lighting
scale 1/4” // 1’-0”
N
8
section
scale 1/8” // 1’-0”
scale 1/4” // 1’-0”
elevation // south wall
9
elevations scale 1/4” // 1’-0”
elevation 1 // west wall
elevation 2 // east wall
elevation 3 // north wall
10
fixture specifications
title
symbol
photo
manufacturer
manufacturers
name
lamp type
ul/ecl
listed no yes yes yes
linear LED
chandelier
hinkley
mercato
fr32548abr
chandelier
120v 60w
LED
incandescent
pendant
lighting
feiss
urban
renewal light
mini pendant
120v 100w
incandescent
incandescent
pendant
lighting
troy lighting
menlo park
light pendant
120v 60w
incandescent
track
lighting
progess
lighting
urban bronze
spotlight
fixture
50w PAR 20
incandescent
11
control specifications
function
symbol
photo
manufacturer
manufacturers
name
size
other
info
garvin
stainless
floor box gfci
receptacle
4”L x 3.5”D
2” aff when
opened
20 amps
stainless
steel
color:
white //
120v // 60
hz
LED recessed
dimmable
lighting
dimmer
switch
lutron
skylark
dimmer
4.69”L x
1.25”D x
2.69”W
toggle
switch
lutron
diva dimmer
switch
S
D
S
S
D
S
4.69”L x
1.25”D x
2.69”W
color:
white //
120v // 60
hz
12
lpd calculations
lpd calculations // ASHRAE standards specifies 1.23 for conference rooms
track lighting chandelier pendant 1 pendant 2
2 fixtures needed
50 watts/fixture
50+50= 100 total
watts
100/285= .35
2 fixtures needed
60 watts/fixture
60+60= 120 total
watts
120/285= .42
2 fixtures needed
100 watts/fixture
100+100= 200 to-
tal watts
200/285= .70
4 fixtures needed
120 watts/fixture
120 x 4= 480
total watts
480/285= 1.68
13
perspectives
15

Weitere ähnliche Inhalte

Ähnlich wie M.Stevens_Final Project_3.12.15 (10)

130515
130515130515
130515
 
Building Science P02
Building Science P02Building Science P02
Building Science P02
 
Project 2 integration project
Project 2 integration projectProject 2 integration project
Project 2 integration project
 
For behance small size
For behance small sizeFor behance small size
For behance small size
 
LED are not enough for a sustainable design
LED are not enough for a sustainable designLED are not enough for a sustainable design
LED are not enough for a sustainable design
 
iGuzzini - Trick
iGuzzini - TrickiGuzzini - Trick
iGuzzini - Trick
 
Lighting Design.pdf
Lighting Design.pdfLighting Design.pdf
Lighting Design.pdf
 
Lighting report
Lighting reportLighting report
Lighting report
 
Daylighting
Daylighting  Daylighting
Daylighting
 
Project 2: Lighting Integration Project
Project 2: Lighting Integration ProjectProject 2: Lighting Integration Project
Project 2: Lighting Integration Project
 

M.Stevens_Final Project_3.12.15

  • 2.
  • 3. TABLEOFCONTENTS lighting concept light map three dimensional light map reflected ceiling plan electrical lighting plan zonal diagram section elevations specifications lpd calculation perspectives 4 5 6 1 3 7 8 9 10 11 12 15 highlighted furniture plan
  • 4.
  • 5. lighting concept The basic need of perfectly schemed general lighting with a hint of excitement and adventure that draws the user to the space. Being a conference room, the lighting needs to be adequate for presentation, pin ups, showcasing and assembly. It `cannot be too bright or overbearing because glass is a major percentage of this design. It will be contained and direct without being too glaring and effecting other areas. Marimekko is a classic company in need of a innovative design to reveal the brilliance of the company. timeless . magnetic . vivacious 1
  • 6.
  • 7. highlighted furniture plan scale 3/32” // 1’-0” scale 1/4” // 1’-0” scale 1/4” // 1’-0” N N N 3
  • 8. light map = daylight = artificial light legend scale 1/4” // 1’-0” 1 2 3 4 5 6 7 1 2 3 4 5 6 7 = direct and moveable task lighting to give light to the wall mounted pinup boards = accent lighting meant to highlight the entrance to the room and draw people in = light to help with wayfinding; to draw people into the room = lighting to give luminance to the conference table and the people working at it = accent lighting and also some general task lighting for the lounge area = natural daylight coming in from the East = generous amount of natural daylight coming through the glass wall of conference room // adjacent to the open N 8 8 = general lighting 4
  • 10. reflected ceiling plan scale 1/4” // 1’-0” N 6
  • 11. scale 1/4” // 1’-0” N electrical lighting plan 7
  • 12. zonal diagram legend = task lighting = general lighting = accent lighting = general lighting scale 1/4” // 1’-0” N 8
  • 13. section scale 1/8” // 1’-0” scale 1/4” // 1’-0” elevation // south wall 9
  • 14. elevations scale 1/4” // 1’-0” elevation 1 // west wall elevation 2 // east wall elevation 3 // north wall 10
  • 15. fixture specifications title symbol photo manufacturer manufacturers name lamp type ul/ecl listed no yes yes yes linear LED chandelier hinkley mercato fr32548abr chandelier 120v 60w LED incandescent pendant lighting feiss urban renewal light mini pendant 120v 100w incandescent incandescent pendant lighting troy lighting menlo park light pendant 120v 60w incandescent track lighting progess lighting urban bronze spotlight fixture 50w PAR 20 incandescent 11
  • 16. control specifications function symbol photo manufacturer manufacturers name size other info garvin stainless floor box gfci receptacle 4”L x 3.5”D 2” aff when opened 20 amps stainless steel color: white // 120v // 60 hz LED recessed dimmable lighting dimmer switch lutron skylark dimmer 4.69”L x 1.25”D x 2.69”W toggle switch lutron diva dimmer switch S D S S D S 4.69”L x 1.25”D x 2.69”W color: white // 120v // 60 hz 12
  • 17. lpd calculations lpd calculations // ASHRAE standards specifies 1.23 for conference rooms track lighting chandelier pendant 1 pendant 2 2 fixtures needed 50 watts/fixture 50+50= 100 total watts 100/285= .35 2 fixtures needed 60 watts/fixture 60+60= 120 total watts 120/285= .42 2 fixtures needed 100 watts/fixture 100+100= 200 to- tal watts 200/285= .70 4 fixtures needed 120 watts/fixture 120 x 4= 480 total watts 480/285= 1.68 13
  • 18.