IDEAL FOR PRESSURE ALARM,
SHUTDOWN, CONTROL ON –
• Machine tools
• Injection molding machines
• Presses
• Pumps
• Hydraulic systems
• Turbines and compressors
• Pipelines
• Most process applications
• All high-cycle applications
N-Series Electronic Pressure Switches
Ashcroft® N-Series electronic pressure
switches have proven reliable in the tough-
est industrial applications. The pressure
sensor is a standard Ashcroft K-Series
thin film transducer. The signal developed
in the transducer is processed on a confor-
mal coated printed circuit board to pro-
duce an output to a high quality electro-
mechanical relay, which is rated for
10,000,000 cycles at rated load! The result
is a long lasting pressure switch that will
outlast mechanical switches in high cycle
applications such as metal stamping
presses, plastic injection molding
machines, and other machine tool and
special equipment. N-Series also features
narrow, adjust-able deadbands that can be
adjusted to less that 0.5% of range, solv-
ing many pipeline and elevated tank appli-
cations that are out of the reach of
mechanical products.
The indicating model is ideally suited for
applications where both a pressure indica-
tor and a switch output for alarm, shut-
down, control or interlock are needed.
Sludge and slurry applications in waste-
water and pulp and paper mills often
require costly diaphragm seals to isolate
instruments from the clogging effects of the
process.You can save money by installing
N-Series with indication on a single seal.
You can even set the switch set and reset
points on a test bench without pressure on
the system, using the indicator and status
lights. Look for these additional features.
BULLETIN SW15
Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA
Tel: 203-378-8281 • Fax: 203-385-0408
email: info@ashcroft.com • www.ashcroft.com
All specifications are subject to change without notice.
All sales subject to standard terms and conditions.
© Ashcroft Inc. 2008 07/14
PERFORMANCE SPECIFICATIONS
Ashcroft Model: N-Series
Accuracy Class (F.S.): 1.0%
Nonlinearity
Terminal Point* ±0.7%
B.F.S.L. ±0.4%
Hysteresis ±0.2%
Nonrepeatability ±0.07%
Interchangeability ±1.0%
*Includes hysteresis
Stability: ±0.5% F.S./year non-cumulative
Durability: 108 cycles 20/80% F.S. with negligible
performance change
Response time: Less than 5m sec
ENVIRONMENTAL CHARACTERISTICS
Temperature Limits:
Storage –65/+250°F
Operating –20/+180°F
Compensated –20/+160°F
Thermal Coefficients (70°F ref.):
Accuracy Zero and Span
1.0% ±0.040% F.S./°F
ELECTRICAL SPECIFICATIONS
Output Signal: Supply Voltage:
4-20mA (2 wire) 36 Vdc unregulated
Reverse polarity protected.
Zero Offset: ±1.0%F.S.
MECHANICAL SPECIFICATIONS
Standard Construction Materials:
Wetted Parts:
Diaphragm — 17-4PH SS
Pressure Connection —316SS
Vmin = 12V+ [.022A*(R L)]
*includes a 10% safety factor
RL = RS + RW
RL = Loop Resistance (ohms)
RS = Sense Resistance (ohms)
RW = Wire Resistance (ohms)
Load Limitations 4-20mA Output
Loop Resistance (Ω)
0 10 12 20 30 36 40
1250
1091
1000
750
500
250
0
545
24
OPERATING
REGION
M.S. Jacobs & Associates
Pittsburgh, PA
800-348-0089
www.msjacobs.com
BULLETIN SW15
Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA
Tel: 203-378-8281 • Fax: 203-385-0408
email: info@ashcroft.com • www.ashcroft.com
All specifications are subject to change without notice.
All sales subject to standard terms and conditions.
© Ashcroft Inc. 2008 07/14
N-Series Electronic Pressure Switches
N-SERIES PRESSURE SWITCH MODEL NUMBER:
To specify the exact switch desired select entries from appropriate tables as shown in example below.
N P A N 4 L S 0 1 X E A 30 PSI
1 2 4 5
D
3 6 7
1 – FUNCTION
NPA – Single setpoint, adjustable deadband
NPI – Single setpoint, adjustable deadband, process
and setpoint indication
2 – ENCLOSURE
N4 – Watertight NEMA 3, 4, 4X, 13 and IP66
N7 – Explosion proof NEMA 3, 4, 4X, 13, 7, 9 and
IP66 – Not available with Model NPI (display)
3 – OUTPUT
D SPDT Relay 10A, 250 Vac
10A, 30 Vdc
I SPDT Relay and 10A, 250 Vac
Current Output 10A, 30 Vdc
and 4-20mA
5 – PRESSURE PORT
Code Description
S01 1
⁄8 NPT Male
S02 1
⁄4 NPT Male
S03 1
⁄8 NPT Female
S04 1
⁄4 NPT Female
S05 7
⁄16-20 SAE-1
⁄4 SAE
S06 1
⁄2 NPT Male 1
⁄4 & NPT Female
S07 1
⁄4 AMINCO – Female
4 – POWER REQUIREMENT
Code
L 110 Vac, 50/60Hz
C 24 Vdc
V 250 Vac, 50/60Hz
6 – N-SERIES OPTIONS
CODE DESCRIPTION
XEA External setpoint adjustment
Consult factory for other options
7 – NOMINAL RANGE
PERFORMANCE TABLE (psi)
Nominal Setpoint psi psi
Range Limits Proof Burst
60 3-60 120 480
100 5-100 200 800
200 10-200 400 1600
300 15-300 600 2400
500 25-500 1000 4000
750 35-750 1500 6000
1000 50-1000 2000 8000
2000 100-2000 4000 16,000
3000 150-3000 4500 20,000
5000 250-5000 7500 22,500
7500 375-7500 9000 25,000
10,000 500-10,000 12,000 30,000
15,000 750-15,000 18,000 45,000
20,000 1000-20,000 24,000 60,000
NOTE: TEMPERATURE SPECIFICATIONS (70°F ref.)
–20°F to 160°F
Setpoint shift of up to 2% of range
per 50°F change can be expected
NEMA 7 (N7)
SP INCR CW
DB INCR CW
3.62
4.37
INDICATING
LEDS
TERMINAL BLOCKS
GROUND SCREW
SETPOINT
ADJUSTMENT
KNOB
DEADBAND
ADJUSTMENT
KNOB
AC AC NC C NO 6.55
3.67
3.96
1.25
3/4 NPT
FEMALE
NOTE:THIS VIEW SHOWN
WITH COVER REMOVED
1/4 NPT MALE
PRESSURE CONNECTION
(92)
(111)
(101)
(32)
(166)
(93)
NEMA 4 (N4)
3.31
3.26
5.62
INDICATING LEDS
NOTE:THIS VIEW SHOWN
WITH COVER REMOVED
TERMINAL
BLOCK
GROUND
SCREW
DEADBAND
ADJUSTMENT
KNOB
SETPOINT ADJUSTMENT KNOB
SP INCR CW
DB INCR CW
AC
AC
NC
C
NO
1.26
3.01
3/4 NPT
1/4 NPT MALE
PRESSURE CONNECTION
(143)
(84)
(83)
(32)
(76)
Weight
1.8 lb
(.81 kg)
Weight
2.7 lb
(1.2 kg)
DIMENSION DRAWINGS

Weitere ähnliche Inhalte

Was ist angesagt?

ASCO Solenoid Valves - Hazardous Area ATEX Certified Valves - New Catalogue
ASCO Solenoid Valves - Hazardous Area ATEX Certified Valves - New CatalogueASCO Solenoid Valves - Hazardous Area ATEX Certified Valves - New Catalogue
ASCO Solenoid Valves - Hazardous Area ATEX Certified Valves - New CatalogueThorne & Derrick International
 
HHE - Low OHM Power Resistors
HHE - Low OHM Power ResistorsHHE - Low OHM Power Resistors
HHE - Low OHM Power Resistorshtrindia
 
Micro ohmmeter test and measurement equipment online store - omni controls ...
Micro ohmmeter   test and measurement equipment online store - omni controls ...Micro ohmmeter   test and measurement equipment online store - omni controls ...
Micro ohmmeter test and measurement equipment online store - omni controls ...omnicontrolsinc
 
HTE - Low OHM Power Resistors
HTE - Low OHM Power ResistorsHTE - Low OHM Power Resistors
HTE - Low OHM Power Resistorshtrindia
 
Jinpat Capsule Slip Ring And Separate Slip Ring
Jinpat Capsule Slip Ring And Separate Slip RingJinpat Capsule Slip Ring And Separate Slip Ring
Jinpat Capsule Slip Ring And Separate Slip RingSarah Wu
 
Servotek encoder2011 catalog
Servotek encoder2011 catalogServotek encoder2011 catalog
Servotek encoder2011 catalogElectromate
 
ASCO Valves - Valve Selection by Alphanumerical Or Numerical System
ASCO Valves - Valve Selection by Alphanumerical Or Numerical SystemASCO Valves - Valve Selection by Alphanumerical Or Numerical System
ASCO Valves - Valve Selection by Alphanumerical Or Numerical SystemThorne & Derrick International
 
HSE - Low OHM Power Resistors
HSE - Low OHM Power ResistorsHSE - Low OHM Power Resistors
HSE - Low OHM Power Resistorshtrindia
 
High range Bellow type Pressure Switch MD series
High range Bellow type Pressure Switch MD seriesHigh range Bellow type Pressure Switch MD series
High range Bellow type Pressure Switch MD seriesNK Instruments Pvt. Ltd.
 
Control Stations - Hazardous Area - Technor AC1WD/DE8BA
Control Stations - Hazardous Area - Technor AC1WD/DE8BA Control Stations - Hazardous Area - Technor AC1WD/DE8BA
Control Stations - Hazardous Area - Technor AC1WD/DE8BA Thorne & Derrick International
 
Ericson Pocket Guide-2014
Ericson Pocket Guide-2014Ericson Pocket Guide-2014
Ericson Pocket Guide-2014Nicole Mezic
 
Thermon FP Heat Tracing Cable - Spec Sheet
Thermon FP Heat Tracing Cable - Spec SheetThermon FP Heat Tracing Cable - Spec Sheet
Thermon FP Heat Tracing Cable - Spec SheetThorne & Derrick UK
 
Nexans Euromold Bushings 800 Amps 12kV - Nexans Euromold 600TBC
Nexans Euromold Bushings 800 Amps 12kV - Nexans Euromold 600TBCNexans Euromold Bushings 800 Amps 12kV - Nexans Euromold 600TBC
Nexans Euromold Bushings 800 Amps 12kV - Nexans Euromold 600TBCThorne & Derrick International
 
Pfisterer Continuous Voltage Indicators for Encapsulated Systems - Pfisterer ...
Pfisterer Continuous Voltage Indicators for Encapsulated Systems - Pfisterer ...Pfisterer Continuous Voltage Indicators for Encapsulated Systems - Pfisterer ...
Pfisterer Continuous Voltage Indicators for Encapsulated Systems - Pfisterer ...Thorne & Derrick International
 

Was ist angesagt? (20)

ASCO Solenoid Valves - Hazardous Area ATEX Certified Valves - New Catalogue
ASCO Solenoid Valves - Hazardous Area ATEX Certified Valves - New CatalogueASCO Solenoid Valves - Hazardous Area ATEX Certified Valves - New Catalogue
ASCO Solenoid Valves - Hazardous Area ATEX Certified Valves - New Catalogue
 
HHE - Low OHM Power Resistors
HHE - Low OHM Power ResistorsHHE - Low OHM Power Resistors
HHE - Low OHM Power Resistors
 
Micro ohmmeter test and measurement equipment online store - omni controls ...
Micro ohmmeter   test and measurement equipment online store - omni controls ...Micro ohmmeter   test and measurement equipment online store - omni controls ...
Micro ohmmeter test and measurement equipment online store - omni controls ...
 
HTE - Low OHM Power Resistors
HTE - Low OHM Power ResistorsHTE - Low OHM Power Resistors
HTE - Low OHM Power Resistors
 
Jinpat Capsule Slip Ring And Separate Slip Ring
Jinpat Capsule Slip Ring And Separate Slip RingJinpat Capsule Slip Ring And Separate Slip Ring
Jinpat Capsule Slip Ring And Separate Slip Ring
 
Heb new
Heb newHeb new
Heb new
 
Level Limit Switch-Soliswitch FTE31
Level Limit Switch-Soliswitch FTE31Level Limit Switch-Soliswitch FTE31
Level Limit Switch-Soliswitch FTE31
 
Thông số kĩ thuật siemens miniature circuit breakers
Thông số kĩ thuật siemens miniature circuit breakersThông số kĩ thuật siemens miniature circuit breakers
Thông số kĩ thuật siemens miniature circuit breakers
 
Servotek encoder2011 catalog
Servotek encoder2011 catalogServotek encoder2011 catalog
Servotek encoder2011 catalog
 
ASCO Valves - Valve Selection by Alphanumerical Or Numerical System
ASCO Valves - Valve Selection by Alphanumerical Or Numerical SystemASCO Valves - Valve Selection by Alphanumerical Or Numerical System
ASCO Valves - Valve Selection by Alphanumerical Or Numerical System
 
HSE - Low OHM Power Resistors
HSE - Low OHM Power ResistorsHSE - Low OHM Power Resistors
HSE - Low OHM Power Resistors
 
High range Bellow type Pressure Switch MD series
High range Bellow type Pressure Switch MD seriesHigh range Bellow type Pressure Switch MD series
High range Bellow type Pressure Switch MD series
 
HANS-S
HANS-SHANS-S
HANS-S
 
Control Stations - Hazardous Area - Technor AC1WD/DE8BA
Control Stations - Hazardous Area - Technor AC1WD/DE8BA Control Stations - Hazardous Area - Technor AC1WD/DE8BA
Control Stations - Hazardous Area - Technor AC1WD/DE8BA
 
Thông số kĩ thuật siemens monitoring devices
Thông số kĩ thuật siemens monitoring devicesThông số kĩ thuật siemens monitoring devices
Thông số kĩ thuật siemens monitoring devices
 
Ericson Pocket Guide-2014
Ericson Pocket Guide-2014Ericson Pocket Guide-2014
Ericson Pocket Guide-2014
 
Thermon FP Heat Tracing Cable - Spec Sheet
Thermon FP Heat Tracing Cable - Spec SheetThermon FP Heat Tracing Cable - Spec Sheet
Thermon FP Heat Tracing Cable - Spec Sheet
 
APMS-75-24
APMS-75-24APMS-75-24
APMS-75-24
 
Nexans Euromold Bushings 800 Amps 12kV - Nexans Euromold 600TBC
Nexans Euromold Bushings 800 Amps 12kV - Nexans Euromold 600TBCNexans Euromold Bushings 800 Amps 12kV - Nexans Euromold 600TBC
Nexans Euromold Bushings 800 Amps 12kV - Nexans Euromold 600TBC
 
Pfisterer Continuous Voltage Indicators for Encapsulated Systems - Pfisterer ...
Pfisterer Continuous Voltage Indicators for Encapsulated Systems - Pfisterer ...Pfisterer Continuous Voltage Indicators for Encapsulated Systems - Pfisterer ...
Pfisterer Continuous Voltage Indicators for Encapsulated Systems - Pfisterer ...
 

Ähnlich wie Electronic Pressure Switch for Industrial Applications

HFP - WIRE WOUND RESISTORS SILICONE COATED TYPE
HFP - WIRE WOUND RESISTORS SILICONE COATED TYPEHFP - WIRE WOUND RESISTORS SILICONE COATED TYPE
HFP - WIRE WOUND RESISTORS SILICONE COATED TYPEhtrindia
 
RK Engineering Load Break Switches.pdf
RK Engineering Load Break Switches.pdfRK Engineering Load Break Switches.pdf
RK Engineering Load Break Switches.pdfRK Engineering
 
Ametek mcg stepper_catalog
Ametek mcg stepper_catalogAmetek mcg stepper_catalog
Ametek mcg stepper_catalogElectromate
 
Datasheet
DatasheetDatasheet
Datasheetky chug
 
Quantum devices qm35 spec
Quantum devices qm35 specQuantum devices qm35 spec
Quantum devices qm35 specElectromate
 
HIA - WIRE WOUND RESISTORS SILICONE COATED TYPE
HIA - WIRE WOUND RESISTORS SILICONE COATED TYPEHIA - WIRE WOUND RESISTORS SILICONE COATED TYPE
HIA - WIRE WOUND RESISTORS SILICONE COATED TYPEhtrindia
 
Advanced motion controls se10a20ac
Advanced motion controls se10a20acAdvanced motion controls se10a20ac
Advanced motion controls se10a20acElectromate
 
Advanced motion controls se10a40ac
Advanced motion controls se10a40acAdvanced motion controls se10a40ac
Advanced motion controls se10a40acElectromate
 
Advanced motion controls se30a20ac
Advanced motion controls se30a20acAdvanced motion controls se30a20ac
Advanced motion controls se30a20acElectromate
 
KEMET Webinar - C4AQ/C4AF power box film capacitors
KEMET Webinar -  C4AQ/C4AF power box film capacitorsKEMET Webinar -  C4AQ/C4AF power box film capacitors
KEMET Webinar - C4AQ/C4AF power box film capacitorsIvana Ivanovska
 
VHIA - 071122.pdf
VHIA -  071122.pdfVHIA -  071122.pdf
VHIA - 071122.pdfhtrindia
 
Explosion Proof/Flame Proof (Ex D) Sensors for Hazardous Area Now Available i...
Explosion Proof/Flame Proof (Ex D) Sensors for Hazardous Area Now Available i...Explosion Proof/Flame Proof (Ex D) Sensors for Hazardous Area Now Available i...
Explosion Proof/Flame Proof (Ex D) Sensors for Hazardous Area Now Available i...Ives Equipment
 
RK Engineering ATS (2).pdf
RK Engineering ATS (2).pdfRK Engineering ATS (2).pdf
RK Engineering ATS (2).pdfRK Engineering
 
Moisture, Hydrogen, and Temperature Measurement in Electrical Transformers
Moisture, Hydrogen, and Temperature Measurement in Electrical TransformersMoisture, Hydrogen, and Temperature Measurement in Electrical Transformers
Moisture, Hydrogen, and Temperature Measurement in Electrical TransformersAlliance Technical Sales, Inc.
 
Catalog Contactor Fuji Electric - Beeteco.com
Catalog Contactor Fuji Electric - Beeteco.comCatalog Contactor Fuji Electric - Beeteco.com
Catalog Contactor Fuji Electric - Beeteco.comBeeteco
 
Catalog contactor fuji-electric Mới Nhất - Hạo Phương
Catalog contactor fuji-electric Mới Nhất - Hạo PhươngCatalog contactor fuji-electric Mới Nhất - Hạo Phương
Catalog contactor fuji-electric Mới Nhất - Hạo PhươngCTY TNHH HẠO PHƯƠNG
 
KEMET Webinar - Long Life and Humidity Grade New Film Box AC Filters
KEMET Webinar - Long Life and Humidity Grade New Film Box AC FiltersKEMET Webinar - Long Life and Humidity Grade New Film Box AC Filters
KEMET Webinar - Long Life and Humidity Grade New Film Box AC FiltersMarkus Trautz
 

Ähnlich wie Electronic Pressure Switch for Industrial Applications (20)

Hazardous Area Pressure Switch
Hazardous Area Pressure SwitchHazardous Area Pressure Switch
Hazardous Area Pressure Switch
 
HFP - WIRE WOUND RESISTORS SILICONE COATED TYPE
HFP - WIRE WOUND RESISTORS SILICONE COATED TYPEHFP - WIRE WOUND RESISTORS SILICONE COATED TYPE
HFP - WIRE WOUND RESISTORS SILICONE COATED TYPE
 
RK Engineering Load Break Switches.pdf
RK Engineering Load Break Switches.pdfRK Engineering Load Break Switches.pdf
RK Engineering Load Break Switches.pdf
 
Ametek mcg stepper_catalog
Ametek mcg stepper_catalogAmetek mcg stepper_catalog
Ametek mcg stepper_catalog
 
Datasheet
DatasheetDatasheet
Datasheet
 
Quantum devices qm35 spec
Quantum devices qm35 specQuantum devices qm35 spec
Quantum devices qm35 spec
 
HIA - WIRE WOUND RESISTORS SILICONE COATED TYPE
HIA - WIRE WOUND RESISTORS SILICONE COATED TYPEHIA - WIRE WOUND RESISTORS SILICONE COATED TYPE
HIA - WIRE WOUND RESISTORS SILICONE COATED TYPE
 
Advanced motion controls se10a20ac
Advanced motion controls se10a20acAdvanced motion controls se10a20ac
Advanced motion controls se10a20ac
 
Advanced motion controls se10a40ac
Advanced motion controls se10a40acAdvanced motion controls se10a40ac
Advanced motion controls se10a40ac
 
Advanced motion controls se30a20ac
Advanced motion controls se30a20acAdvanced motion controls se30a20ac
Advanced motion controls se30a20ac
 
Aiikoh general catalog (en) denkei
Aiikoh general catalog (en) denkeiAiikoh general catalog (en) denkei
Aiikoh general catalog (en) denkei
 
KEMET Webinar - C4AQ/C4AF power box film capacitors
KEMET Webinar -  C4AQ/C4AF power box film capacitorsKEMET Webinar -  C4AQ/C4AF power box film capacitors
KEMET Webinar - C4AQ/C4AF power box film capacitors
 
VHIA - 071122.pdf
VHIA -  071122.pdfVHIA -  071122.pdf
VHIA - 071122.pdf
 
Explosion Proof/Flame Proof (Ex D) Sensors for Hazardous Area Now Available i...
Explosion Proof/Flame Proof (Ex D) Sensors for Hazardous Area Now Available i...Explosion Proof/Flame Proof (Ex D) Sensors for Hazardous Area Now Available i...
Explosion Proof/Flame Proof (Ex D) Sensors for Hazardous Area Now Available i...
 
RK Engineering ATS (2).pdf
RK Engineering ATS (2).pdfRK Engineering ATS (2).pdf
RK Engineering ATS (2).pdf
 
Moisture, Hydrogen, and Temperature Measurement in Electrical Transformers
Moisture, Hydrogen, and Temperature Measurement in Electrical TransformersMoisture, Hydrogen, and Temperature Measurement in Electrical Transformers
Moisture, Hydrogen, and Temperature Measurement in Electrical Transformers
 
Catalog Contactor Fuji Electric - Beeteco.com
Catalog Contactor Fuji Electric - Beeteco.comCatalog Contactor Fuji Electric - Beeteco.com
Catalog Contactor Fuji Electric - Beeteco.com
 
Catalog contactor fuji-electric Mới Nhất - Hạo Phương
Catalog contactor fuji-electric Mới Nhất - Hạo PhươngCatalog contactor fuji-electric Mới Nhất - Hạo Phương
Catalog contactor fuji-electric Mới Nhất - Hạo Phương
 
KEMET Webinar - Long Life and Humidity Grade New Film Box AC Filters
KEMET Webinar - Long Life and Humidity Grade New Film Box AC FiltersKEMET Webinar - Long Life and Humidity Grade New Film Box AC Filters
KEMET Webinar - Long Life and Humidity Grade New Film Box AC Filters
 
HHE
HHEHHE
HHE
 

Kürzlich hochgeladen

Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxupamatechverse
 
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...ranjana rawat
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Bookingdharasingh5698
 
Extrusion Processes and Their Limitations
Extrusion Processes and Their LimitationsExtrusion Processes and Their Limitations
Extrusion Processes and Their Limitations120cr0395
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxpranjaldaimarysona
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxupamatechverse
 
University management System project report..pdf
University management System project report..pdfUniversity management System project report..pdf
University management System project report..pdfKamal Acharya
 
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordCCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordAsst.prof M.Gokilavani
 
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escortsranjana rawat
 
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfKamal Acharya
 
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls in Nagpur High Profile
 
UNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and workingUNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and workingrknatarajan
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxBSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxfenichawla
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Call Girls in Nagpur High Profile
 
UNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular ConduitsUNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular Conduitsrknatarajan
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxAsutosh Ranjan
 
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...Call Girls in Nagpur High Profile
 

Kürzlich hochgeladen (20)

Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptx
 
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
 
Extrusion Processes and Their Limitations
Extrusion Processes and Their LimitationsExtrusion Processes and Their Limitations
Extrusion Processes and Their Limitations
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptx
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptx
 
University management System project report..pdf
University management System project report..pdfUniversity management System project report..pdf
University management System project report..pdf
 
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordCCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
 
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
 
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
 
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
 
UNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and workingUNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and working
 
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
 
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxBSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
UNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular ConduitsUNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular Conduits
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptx
 
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
 

Electronic Pressure Switch for Industrial Applications

  • 1. IDEAL FOR PRESSURE ALARM, SHUTDOWN, CONTROL ON – • Machine tools • Injection molding machines • Presses • Pumps • Hydraulic systems • Turbines and compressors • Pipelines • Most process applications • All high-cycle applications N-Series Electronic Pressure Switches Ashcroft® N-Series electronic pressure switches have proven reliable in the tough- est industrial applications. The pressure sensor is a standard Ashcroft K-Series thin film transducer. The signal developed in the transducer is processed on a confor- mal coated printed circuit board to pro- duce an output to a high quality electro- mechanical relay, which is rated for 10,000,000 cycles at rated load! The result is a long lasting pressure switch that will outlast mechanical switches in high cycle applications such as metal stamping presses, plastic injection molding machines, and other machine tool and special equipment. N-Series also features narrow, adjust-able deadbands that can be adjusted to less that 0.5% of range, solv- ing many pipeline and elevated tank appli- cations that are out of the reach of mechanical products. The indicating model is ideally suited for applications where both a pressure indica- tor and a switch output for alarm, shut- down, control or interlock are needed. Sludge and slurry applications in waste- water and pulp and paper mills often require costly diaphragm seals to isolate instruments from the clogging effects of the process.You can save money by installing N-Series with indication on a single seal. You can even set the switch set and reset points on a test bench without pressure on the system, using the indicator and status lights. Look for these additional features. BULLETIN SW15 Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA Tel: 203-378-8281 • Fax: 203-385-0408 email: info@ashcroft.com • www.ashcroft.com All specifications are subject to change without notice. All sales subject to standard terms and conditions. © Ashcroft Inc. 2008 07/14 PERFORMANCE SPECIFICATIONS Ashcroft Model: N-Series Accuracy Class (F.S.): 1.0% Nonlinearity Terminal Point* ±0.7% B.F.S.L. ±0.4% Hysteresis ±0.2% Nonrepeatability ±0.07% Interchangeability ±1.0% *Includes hysteresis Stability: ±0.5% F.S./year non-cumulative Durability: 108 cycles 20/80% F.S. with negligible performance change Response time: Less than 5m sec ENVIRONMENTAL CHARACTERISTICS Temperature Limits: Storage –65/+250°F Operating –20/+180°F Compensated –20/+160°F Thermal Coefficients (70°F ref.): Accuracy Zero and Span 1.0% ±0.040% F.S./°F ELECTRICAL SPECIFICATIONS Output Signal: Supply Voltage: 4-20mA (2 wire) 36 Vdc unregulated Reverse polarity protected. Zero Offset: ±1.0%F.S. MECHANICAL SPECIFICATIONS Standard Construction Materials: Wetted Parts: Diaphragm — 17-4PH SS Pressure Connection —316SS Vmin = 12V+ [.022A*(R L)] *includes a 10% safety factor RL = RS + RW RL = Loop Resistance (ohms) RS = Sense Resistance (ohms) RW = Wire Resistance (ohms) Load Limitations 4-20mA Output Loop Resistance (Ω) 0 10 12 20 30 36 40 1250 1091 1000 750 500 250 0 545 24 OPERATING REGION M.S. Jacobs & Associates Pittsburgh, PA 800-348-0089 www.msjacobs.com
  • 2. BULLETIN SW15 Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA Tel: 203-378-8281 • Fax: 203-385-0408 email: info@ashcroft.com • www.ashcroft.com All specifications are subject to change without notice. All sales subject to standard terms and conditions. © Ashcroft Inc. 2008 07/14 N-Series Electronic Pressure Switches N-SERIES PRESSURE SWITCH MODEL NUMBER: To specify the exact switch desired select entries from appropriate tables as shown in example below. N P A N 4 L S 0 1 X E A 30 PSI 1 2 4 5 D 3 6 7 1 – FUNCTION NPA – Single setpoint, adjustable deadband NPI – Single setpoint, adjustable deadband, process and setpoint indication 2 – ENCLOSURE N4 – Watertight NEMA 3, 4, 4X, 13 and IP66 N7 – Explosion proof NEMA 3, 4, 4X, 13, 7, 9 and IP66 – Not available with Model NPI (display) 3 – OUTPUT D SPDT Relay 10A, 250 Vac 10A, 30 Vdc I SPDT Relay and 10A, 250 Vac Current Output 10A, 30 Vdc and 4-20mA 5 – PRESSURE PORT Code Description S01 1 ⁄8 NPT Male S02 1 ⁄4 NPT Male S03 1 ⁄8 NPT Female S04 1 ⁄4 NPT Female S05 7 ⁄16-20 SAE-1 ⁄4 SAE S06 1 ⁄2 NPT Male 1 ⁄4 & NPT Female S07 1 ⁄4 AMINCO – Female 4 – POWER REQUIREMENT Code L 110 Vac, 50/60Hz C 24 Vdc V 250 Vac, 50/60Hz 6 – N-SERIES OPTIONS CODE DESCRIPTION XEA External setpoint adjustment Consult factory for other options 7 – NOMINAL RANGE PERFORMANCE TABLE (psi) Nominal Setpoint psi psi Range Limits Proof Burst 60 3-60 120 480 100 5-100 200 800 200 10-200 400 1600 300 15-300 600 2400 500 25-500 1000 4000 750 35-750 1500 6000 1000 50-1000 2000 8000 2000 100-2000 4000 16,000 3000 150-3000 4500 20,000 5000 250-5000 7500 22,500 7500 375-7500 9000 25,000 10,000 500-10,000 12,000 30,000 15,000 750-15,000 18,000 45,000 20,000 1000-20,000 24,000 60,000 NOTE: TEMPERATURE SPECIFICATIONS (70°F ref.) –20°F to 160°F Setpoint shift of up to 2% of range per 50°F change can be expected NEMA 7 (N7) SP INCR CW DB INCR CW 3.62 4.37 INDICATING LEDS TERMINAL BLOCKS GROUND SCREW SETPOINT ADJUSTMENT KNOB DEADBAND ADJUSTMENT KNOB AC AC NC C NO 6.55 3.67 3.96 1.25 3/4 NPT FEMALE NOTE:THIS VIEW SHOWN WITH COVER REMOVED 1/4 NPT MALE PRESSURE CONNECTION (92) (111) (101) (32) (166) (93) NEMA 4 (N4) 3.31 3.26 5.62 INDICATING LEDS NOTE:THIS VIEW SHOWN WITH COVER REMOVED TERMINAL BLOCK GROUND SCREW DEADBAND ADJUSTMENT KNOB SETPOINT ADJUSTMENT KNOB SP INCR CW DB INCR CW AC AC NC C NO 1.26 3.01 3/4 NPT 1/4 NPT MALE PRESSURE CONNECTION (143) (84) (83) (32) (76) Weight 1.8 lb (.81 kg) Weight 2.7 lb (1.2 kg) DIMENSION DRAWINGS