SlideShare ist ein Scribd-Unternehmen logo
1 von 70
HIGH PERFORMANCE LIQUID
CHROMATOGRAPHY [HPLC]
Mr. Khalid Nadeem Blouch
Mr. Muhammad illyas
Mr. Muhammad Haris
[Department of chemistry (Physical chem)]
1
Institute of chemical sciences ( BZU) Multan
25.03.2023
CHROMATOGRAPHY
 It is define as an analytical method in which separation of active constituent
in complex mixture, which was distributed in two phases i.e. stationary phase
and mobile phase is known as chromatography.
Use of CHROMATOGRAPHY
 This technique is used for
1. separation,
2
Use of CHROMATOGRAPHY
 This technique is used for
1. separation,
2. purification,
2
Use of CHROMATOGRAPHY
 This technique is used for
1. separation,
2. purification,
3. Identification and
2
Use of CHROMATOGRAPHY
 This technique is used for
1. separation,
2. purification,
3. Identification and
4. extraction of compound.
 Details of its application will be discussed at the end
2
Some definitions
 Stationary phase is constant phase or column packaging material.
 Mobile phase is moveable phase.
 The basic principle of chromatography is based on Adsorption and
partition chromatography.
 Adsorption chromatography - The affinity of molecules towards stationary phase
is known as Adsorption chromatography.
 Partition chromatography - The molecule can moves in two phases of liquid is
known as partition chromatography.
 Qualitative Analysis: identification of the constituents
 Quantitative analysis. Quantification of the constituents
TYPES OF CHROMATOGRAPHY
 Based on modes of chromatography
1. Normal phase mode
2.Reverse phase mode
 Based on principle of separation
1. Adsorption chromatography
2. Ion exchange chromatography
3. Partition chromatography
4. Size exclusion
 Based on elution technique
1. Isocratic separation
2. Gradient separation
 Based on the scale of operation
1. Analytical HPLC
2. Preparative HPLC
 Based on the type of analysis
1. Qualitative analysis
2. Quantitative analysis
3
PRINCIPLES OF LIQUID CHROMATOGRAPHY
9
TYPES OF LIQUID CHROMATOGRAPHY
1
0
HPLC
1
1
 HPLC is a High Performance liquid Chromatography.
 High Pressure Liquid Chromatography.
 High Priced Liquid Chromatography.
 It is column chromatography.
 It is Liquid Chromatography.
 It is modified from of gas chromatography, it is applicable for both Volatile as well as
Non volatile compound.
 It can mainly divided by two types 1. Normal phase HPLC 2. Reversed Phase HPLC.
 It is having a high resolution and separation capacity.
 It is used as qualitative as well as quantitative analysis.
 High performance liquid chromatography (HPLC) is a chromatographic technique used
to separate a mixture of compounds in analytical chemistry and biochemistry with the
purpose of identifying, quantifying or purifying the individual components of the
mixture.
1
2
PRINCIPLE
1
3
 High Performance Liquid Chromatography [HPLC] is principle is based on
adsorption as well as partition chromatography is depending on the nature
of stationary phase, if stationary phase is solid principle is based on adsorption
chromatography and if stationary phase is liquid principle is based on partition
chromatography.
 It is important for determination of volatile and non volatile compounds.
 It is important for determination qualitative and quantitative analysis.
 It is important for determination of Retention Time (the time is required , after
sample injection maximum angle peak reaches to detector)
1
4
ADVANTAGES
 It is simple, rapid , reproducible.
 High sensitivity.
 High performance.
 Rapid process and hence time saving.
 It is having a high resolution and separation capacity.
 Accuracy and Precision.
 Stationary phase was chemically innert.
 Wide varities of stationary phase.
 Mobile phase was chemically innert.
 Less requirement of mobile phase in developing chamber.
 Early recovery of separated component.
 Easy visualization of separated components.
 It is having Good reproducibility and repeatability.
 It is analytical technique is important for validation of product, quality control
studies of product.
 It is important for qualitative and quantitative analysis.
 It is used for both analytical and preparative purpose.
10
TYPES OF HPLC SEPARATIONS
16
 Normal Phase: Separation of polar analytes by partitioning onto a polar, bonded
stationary phase.
 Reversed Phase: Separation of non-polar analytes by partitioning onto a non-polar,
bonded stationary phase.
 Adsorption: In Between Normal and Reversed. Separation of moderately polar analytes
using adsorption onto a pure stationary phase (e.g. alumina or silica)
 Ion Chromatography: Separation of organic and inorganic ions by their partitioning
onto ionic stationary phases bonded to a solid support.
 Size Exclusion Chromatography: Separation of large molecules based in the paths they
take through a “maze” of tunnels in the stationary phase.
HPLC METHODS
17
 Parameter Group Method Compounds
• SDW05.23000’s EPA555 Cl-PhenoxyAcids
• WPP05.06000’s EPA605 Benzidines
• WPP05.13000’s EPA610 PAHs
• SHW06.26000’s SW-846 8316 Acrylics
• SHW06.28000’s SW-846 8330’s Explosives
• SHW07.06000’s SW-846 8325 Benzidines and
N- Pesticides
MODES OF HIGH PERFORMANCE LIQUID
CHROMATOGRAPHY
13
Types of Compounds Mode Stationary
Phase
Mobile Phase
Neutrals
Weak Acids
Weak Bases
Reversed
Phase
C18, C8, C4
cyano, amino
Water/Organic
Modifiers
Ionics, Bases,Acids Ion
Pair
C-18, C-8 Water/Organic
Ion-Pair Reagent
Compounds not
soluble in water
Normal
Phase
Silica,Amino,
Cyano, Diol
Organics
Ionics Inorganic Ions Ion
Exchange
Anion or Cation
Exchange
Resin
Aqueous/Buffer
Counter Ion
High Molecular Weight
Compounds
Polymers
Size
Exclusion
Polystyrene
Silica
Gel Filtration-
Aqueous
Gel Permeation-
Organic
HPLC CONTAIN
 Stationary Phase - It is non polar and The stationary solid surface is coated with a 2nd liquid (the
Stationary Phase) which is immiscible with mobile phase.
 Mobile Phase - A polar mobile phase(ACN, MeOH, WATER + BUFFER).
Bonded Phases -
19
-Si-(CH2)3-CN
-Si-(CH2)17-CH3
 C-2 Ethyl Silyl
• C-8 Octyl Silyl
• C-18 Octadecyl Silyl
• CN Cyanopropyl Silyl
-Si-CH2-CH3
-Si-(CH2)7-CH3
BLOCK DIAGRAM OF HPLC
20
Reservoir
Pump Gradient
controller
Mixing
chamber
Pump
Solvent
Conditioning
column
Reservoir
Injector Precolumn
Analytical
column
Detector
Recorder
Fraction
collector
WHY USE HPLC
21
 Simultaneous analysis
 High resolution
 High sensitivity
 Good repeatability
 Moderate analysis condition
 Easy to fractionate and purify
 Not destructive
INSTRUMENTATION OF HPLC
22
 Solvent storage bottle
 Gradient controller and mixing unit
 De-gassing of solvents
 Pump
 Pressure gauge
 Pre-column
 Sample introduction system
 Column
 Detector
 Recorder
23
24
25
26
27
23
23
OUTLINE OF LC-2010
System Controller
UV detector
Auto sampler
Column Oven
Pump Unit
Reservior Tray
Degassing Unit
Low pressure
gradient device
24
HPLC SYSTEM
9010 Solvent
Delivery System
9050 Variable
UV/Vis Detector
HPLC Solvent
Reservoirs
HPLC
Column
Rheodyne
Injector
9060 Polychrom
(Diode Array) Detector
Computer
Workstation
SOLVENT/ MOBILE PHASE RESERVOIRS
 Glass or stainless-steel containers capable of holding up to
1 liter mobile phase (pure organic solvents or aqueous
solutions of salts and buffers)
 Inert to a variety of aqueous and non aqueous mobile
phases.
 Stainless steel should be avoided for use with solvents
containing halide ions.
25
DEGASSING & FILTRATION OF MOBILE PHASE
 In many cases, aqueous solvents & some organic solvents are degassed prior
to use
 Degassing is done to prevent formation of gas bubbles in the pump or
detector ( Mobile phases are degassed by stirring of the mobile phase under
vacuum, sonication or sparing with helium gas)
 The mobile phase are filtered to remove particulate matter that may clog the
system
Tubing
 Should be inert,
 have ability to withstand pressure
 able to carry sufficient volume 26
PUMP
32
 The solvents or mobile phase must be passed through a column at high
pressures at up to 6000 psi(lb/in²) or 414 bar.
 As the particle size of stationary phase is smaller (5 to 10µ) the resistance to the
flow of solvent will be high.
 That is, smaller the particle size of the stationary phase the greater is the
resistance to the flow of solvents.
 Hence high pressure is recommended.
REQUIREMENTS FOR PUMPS
33
 Generation of pressure of about 6000 psi.
 Pulse free output & all materials in the pump should be chemically resistant to
solvents.
 Flow rates ranging from 0.1 to 10 mL/min
 Pumps should be capable of taking the solvent from a single reservoir or more
than one reservoir containing different solventssimultaneously.
Types of pumps
used in HPLC
34
DISPLACEMENT
PUMPS
RECIPROCATING
PUMPS
PNEUMATIC
PUMPS
HPLC Pump
Constant flow rate (Mechanical) Pump Constant Pressure Pump (Pneumatic)
Manner in which they operate
syringe
(Displace
ment
pump)
Reciprocating pump
Single
piston
reciprocati
ng pump
Double piston
reciprocating
pump
Reciprocating
diaphragm
pump
Direct pressure pump Amplifier pump
35
DISPLACEMENT PUMPS
36
It consists of large, syringe like chambers equipped with a plunger
activated by a screw driven mechanism powered by a stepping
motor.
So it is also called as Screw Driven Syringe Type Pump.
Advantages:- It produces a flow that tends to be independent of
viscosity & back pressure.
Disadvantages:- It has a limited solvent capacity(~250) &
considerably inconvenient when solvents must be changed.
37
RECIPROCATING PUMPS
 This pump transmits alternative pressure to the solvent via a
flexible diaphragm ,which in turn is hydraulically pumped by a
reciprocating pump.
 Disadvantages
Produces a pulsed flow which is damped because pulses appear as
baseline noise on the chromatograph.
This can be overcome by use of dual pump heads or elliptical
cams to minimize such pulsations. 33
motor and cam
plunger
check valve
pump head
5 - 50µL
out
plunger seal
in
Mobile phase
check valve
39
 Solvent is pumped back and forth by a motor driven piston
 Two ball check valves which open & close which controls the flow
 The piston is in direct contact with the solvent
 Small internal volume 35-400μL
 High output pressure up to 10,000 psi
 Ready adaptability to gradient elution and constant flow rate
40
36
A. Single-piston pump with slow filling
cycle
B. Single-piston pump with a rapid filling cycle
C.Adual-piston pump with rapid filling cycles and operate 1800
out of phase.
Schematic representation of solvent flow from
 Advantages
 Have small internal volume of 35-400µL
 Higher output pressures up to 10,000 psi.
 Adaptability to gradient elution.
 Large solvent capacities & constant flow rates.
 Largely independent of column back pressure & solvent viscosity.
42
PNEUMATIC PUMPS
43
 In this pumps, the mobile phase is driven through the column with the use of
pressure produced from a gas cylinder.
 It has limited capacity of solvent
 Due to solvent viscosity back pressure may develop.
SAMPLE INJECTOR SYSTEM
44
 Several injector devices are available either for manual or auto
injection of the sample.
(i) Septum Injector
(ii) Stop Flow Injector
(iii) Rheodyne Injector
i. SEPTUM INJECTOR
45
These are used for injecting the sample through a rubber septum.
This kind of injectors cannot be commonly used , since the septum
has to withstand high pressures.
ii. Stop Flow
 In this type the flow of mobile phase is stopped for a while & the
sample is injected through a valve.
III. RHEODYNE INJECTOR
46
 It is the most popular injector and is widely used.
 This has a fixed volume of loop, for holding sample until its injected into the
column, like 20µL, 50µL or more.
 Through an injector the sample is introduced into the column.
 The injector is positioned just before the inlet of the column.
47
SELECTION VALVE
BY USING THE SELECTION VALVE
WE CAN SELECT WHETHER THE
PURPOSE IS FOR ANALYTICAL
PURPOSE OR PREPARATIVE
PURPOSE.
INJECT POSITION
In this position the loaded
sample is injected into the
column by the forceful flow
of the solvent into the sample
loop by which the sample is
introduced into the column.
LOAD POSITION
In this position the sample is
loaded into the sample loop .
43
43
44
44
HPLC AUTO INJECTORS
Inside of SIL-20AC
COLUMN
1. Precolumn
1. It contains a packing chemically identical to that in analytical column.
2.Mainly used to remove the impurities from the solvent and thus prevents contamination of the analytical
column, it can protect analytical column.
3. It is also called as guard column or protective column.
4. it is having large particle size.
5. It is having short length of 2 to 10 cm, so does not affect separation.
2. Analytical column
1. The success or failure of analysis depends upon choice of column.
2. Actual separation is carried out here.
3. Stainless –steel tube
4. size – length -25 to 100 cm
5. Internal diameter – 2 to 4.6 mm
6. Column is filled with small particles 5 – 10 micron. The solid support can be silica gel, alumina.
7. The separation is result of different components adhering to or diffusion into the packing particles when
the mobile phase is forced through column.
45
8.C8 and C18 columns are considered as examples of reversed phase liquid
chromatography (RP).
9.The stationary phase here is seen as a thin film of non-polar liquid phase that has
been designed to be chemically similar to an inert material (Silica gel particles).
10.The non-polar layer is chemically linked to the silica particles surface by
reaction with the polar silanol groups on the stationary phase surface and so
rendering them less polar or non-polar.
11. The difference between the two columns will be in the length of the carbon-
chain attached to the silica surface.
12.Accordingly C8 hplc columns have packing material composed of silica
particles attached to C8 carbon units.
13. C18 will, of course, have packing materials coated with C18 hydrophobic
units.
14.Categorically both are reversed phase but C18 columns will definitely be more
"hydrophobic rather than the C8 columns.
51
DETECTORS
52
 Absorbance (UV/Vis and PDA)
 Refractive index (detects the change in turbidity)
 Fluorescence (if the analyte is fluorescent)
 Electrochemical (measures current flowing through a pair of electrodes, on
which a potential difference is imposed, due to oxidation or reduction of
solute)
 Conductivity (for ions)
 Light scattering
 Mass spectrometry (HPLC-MS)
SELECTION OF DETECTORS
 Compounds with chromophores, such as aromatic rings
multiple alternating double bonds.
 Fluorescent compounds, usually with fused rings or high
conjugated planar system.
 Charged compounds, such as inorganic ions and organi
acid.
53
Detectors Type of compounds can be detected
UV-Vis & PDA
RF
CDD
ECD For easily oxidized compounds like quinones or amines.
RID & ELSD
For compounds that do not show characteristics usable by
the other detectors, e.g. polymers, saccharides.
TYPES OF HPLC DETECTORS
UV-Vis Works w/all molecules Non-specific; complex
samples; absorption
wavelength
DAD Works for all wavelengths High LOD
Fluorescence Very specific; low LOD Not everything fluoresces
IR Works w/all molecules Many solvents IR active
Refractive Index Works w/nearly all
molecules
Temperature sensitive;
high LOD
Scattering Uniform response;
5ng/25mL LOD
Non-specific; interference
from solvent
Electrochemical Commercially available Non-specific; high LOD
Mass Spec Low LOD; analyte
identification
Ability to ionize analyte
49
Name Advantage Disadvantage
IDEAL DETECTOR PROPERTIES
55
 High Sensitivity
 Universality or predictable specificity
 Large linear response range
 Low dead volume
 Non-Destructive
 Insensitive to temperature & mobile phase
 Continuous operation
 Reliable and easy to use
 No single detector fits all these criteria
UV-VISIBLE DETECTOR
56
 UV visible detector is widely used as it detects large number of compounds
because most drugs have appropriate structural characteristics for light
absorption.
 These are useful for aromatic compounds and other type of unsaturatedsystems.
 These are classified as fixed or variable wavelength detectors.
 Fixed wavelength detectors employ filter as a source to provide appropriate
wavelength.
 Most common fixed wavelength detectors are based on 254 nm.
 Variable wavelength detectors are employ a spectrophotometer to provide
dispersion of light and selection of any wavelength in UV visibleregions.
 Diffraction gratings are frequently used for wavelengthdispersion.
57
REFRACTIVE INDEX (RI) DETECTOR
58
 Detection occurs when the light is bent due to samples eluting from the columns, and
this is read as a disparity b/w the two channels.
 It is not much used for analytical applications because of low sensitivity & specificity.
 When a solute is in the sample compartment, refractive index changes will shift the light
beam from the detector.
PHOTODIODE
ARRAY (PDA)
59
 A photodiode array (PDA) is a linear array of discrete photodiodes on an integrated
circuit (IC) chip.
 Allows a range of wavelengths to be detected simultaneously. In this regard it can be
thought of as an electronic version of photographic film. Array detectors are especially
useful for recording the full Uv- vis is a absorption spectra of samples that are rapidly
passing through a sample flow cell, such as in an HPLC detector.
 PDAs work on the same principle as simple. Photovoltaic detector
 similar to UV detector, non destructive 190-600 nm for quantization & identification
Spectra is 3D, Response vs time vs WL.
FLUORIMETRIC DETECTORS
detector while a
 It is based on the fluorescent radiation emitted by some compounds.
 The excitation source passes through the flow cell to a photo
monochromatic measures the emission wavelengths.
 More sensitive and specific.
 The disadvantage is that most compounds are not fluorescent in nature.
 Fluorescence is a type of luminescence in which the light energy is released in the form of
a photon in nanoseconds to microseconds.
55
S1
T1
S0
Light absorption
Non-radiation transition
Non-radiation transition
Fluorescence
Phosphorescence
61
62
RECORDERS AND INTEGRATORS
63
 Recorders are used to record responses obtained from the detectors after amplification, if
necessary.
 They record the baseline & all the peaks obtained with respect tot time.
 Retention time can be found out from this recordings, but area under curve cannot be
determined.
 The Integrators are improved versions of recorders with some data processing
capabilities.
 They can record the individual peaks with retention time, height, width of peaks, peak
area, percentage area, etc.
 Integrators provides more information on peaks than recorders.
 In recent days computers and printers are used for recording and processing the obtained
data & for controlling several operations.
COMPARISION BETWEEN HPTLC AND HPLC
Sr.no. HPTLC HPLC
1 High Performance Thin Layer High
Chromatography
Performance Liquid
Chromatography
2 Column Chromatography
3 Adsorption
Planar Chromatography
Principle based on
Chromatography
Principle is based on Adsorption and
Partition Chromatography
4 Simultaneous method for test as well as
reference material
Not simultaneous method for test as
well as reference material
5 It is simple, rapid, reproducible method It is Tedious method
6 Sample preparation is simple Sample preparation is complex
7 Limited Flexibility Extreme Flexibility
8 Semiautomatic Technique Automatic (Instrumental) Technique
59
9 Determination of SurfaceArea Determination of Retention Time
COMPARISION BETWEEN GC AND HPLC
60
SR.NO. GC HPLC
1 Gas Chromatography High Performance Liquid
Chromatography
2 Less resolution High resolution
3 Limited Flexibility Extreme Flexibility
4 Determination of Volatile
compounds
Determination of Volatile and Non
Volatile Compounds
COMPARISION BETWEEN HPLC AND UPLC
Parameters HPLC Assay UPLC Assay
Column XTerra,C18,50 ×
4.6mm
AQUITY UPLC BEH
C18,50 ×2.1mm
Particle size 4µm particles 1.7µm particles
Flow rate 3.0 ml per min 0.6 ml per min
Injection volume 20 µl 3 µl partial loop fill or
5 µl full loop fill
Total run time 10 min 1.5 min
Theoretical Plate 2000 7500
count 61
62
Parameters HPLC Assay UPLC Assay
Lower limit of
quantization
0.2 µg/ml 0.054µl/ml
Total solvent
consumption
Acetonitrile:10.5ml,
water:21ml
Acetonitrile:0.53ml,
water:0.66ml
Delay volume 720 µl 110 µl
Column temperature 30 °C 65 °C
Maximum back
pressure
35-40 Mpa
less
103.5 Mpa
more
Resolution Less High
Method development
cost
High Low
APPLICATION
 Drug Discovery
 ClinicalAnalysis
 Proteomics
 Forensic Chemistry
 Drug Metabolism study
 Environmental chemistry
 Diagnostic studies
 Cosmetic analysis
 Determination of Green Florescent Protein
 Structural Determination
 PharmaceuticalApplications
 Identification of Bile Acid Metabolite
 ClinicalApplications
 Biochemical Genetics
 qualitative and quantitative analysis
 Therapeutic Drug Monitoring
63
REFERENCE
 Knox JH, DoneJN, Fell AF et al. High-Performance Liquid
Chromatography. Edinburgh: Edinburgh University Press; 1978.
 Simpson CF. Practical High-Performance Liquid Chromatography. London: Heyd
and Son; 1976.
 Pungor E. A Practical Guide to Instrumental Analysis. Boca Raton: CRC Press; 19
 Moffat AC, Osselton MD, Widdop B. Clarke’s Analysis of Drugs and Poisons. Lon
Pharmace utical Press; 2004.
 Y. Shen and R.D. Smith, Electrophoresis 23 (2002) pp. 3106-3124.
 D.A. Skoog and D.M. West, Fundamentals of Analytical Chemistry, 3rd edit., pp. 64
 D. Sievers, M.E. Swartz and B.J. Murphy, G.I.T. Laboratory Journal(2004) pp.43
45.(2004) pp.
 503-504
 L.A. Colon, J.M. Cintron, J.A. Anspach, A.M. Fermier and K.A. Swinney, The Analy
 L.R. Snyder, J.J. Kirkland and J.L. Glajch, Practical HPLC Method development, 2n
edit., pp. 41- 43.
and J.W. Jorgenson, LCGC 21 (July 2003) pp. 600-611. 64
65

Weitere ähnliche Inhalte

Ähnlich wie HPLC ppt 1 BZU.pptx

High pressure liquid chromatography, B.Pharm
High pressure liquid chromatography, B.PharmHigh pressure liquid chromatography, B.Pharm
High pressure liquid chromatography, B.PharmSalnaSusanAbraham
 
Hplc by Bachaspati jana
Hplc by  Bachaspati janaHplc by  Bachaspati jana
Hplc by Bachaspati janaBachaspatiJana
 
High Performance Liquid Chromatography..
High Performance Liquid Chromatography..High Performance Liquid Chromatography..
High Performance Liquid Chromatography..Somnath Patil
 
High Performance Liquid Chromatography (HPLC)
High Performance Liquid Chromatography (HPLC)High Performance Liquid Chromatography (HPLC)
High Performance Liquid Chromatography (HPLC)SACHINKUMARVISHWAKAR4
 
High Performance Liquid Chromatography (HPLC)
High Performance Liquid Chromatography (HPLC)High Performance Liquid Chromatography (HPLC)
High Performance Liquid Chromatography (HPLC)Tulsi Makwana
 
A brief review on development and validation of hplc method.
A brief review on development and validation of hplc method.A brief review on development and validation of hplc method.
A brief review on development and validation of hplc method.adhirajain
 
HPLC & UPLC omkar.pptx isf college of pharmacy moga
HPLC & UPLC omkar.pptx isf college of pharmacy  mogaHPLC & UPLC omkar.pptx isf college of pharmacy  moga
HPLC & UPLC omkar.pptx isf college of pharmacy mogaISF COLLEGE OF PHARMACY
 
High Performance Liquid Chromatography
High Performance Liquid ChromatographyHigh Performance Liquid Chromatography
High Performance Liquid ChromatographyPayal Vaswani
 
HIGH PERFORMANCE LIQUID CHROMATOGRAPHY/SAGAR/SHARMA/DEPARTMENT OF PHARMACEUTI...
HIGH PERFORMANCE LIQUID CHROMATOGRAPHY/SAGAR/SHARMA/DEPARTMENT OF PHARMACEUTI...HIGH PERFORMANCE LIQUID CHROMATOGRAPHY/SAGAR/SHARMA/DEPARTMENT OF PHARMACEUTI...
HIGH PERFORMANCE LIQUID CHROMATOGRAPHY/SAGAR/SHARMA/DEPARTMENT OF PHARMACEUTI...SagarMudgil1
 
High performance liquid chromatography
High performance liquid chromatographyHigh performance liquid chromatography
High performance liquid chromatographyBinodBashyal2
 
HPLC -ARUN NIVAS V PERIYAR COLLEGE OF PHARMACEUTICAL SCIENCES, TRICHY-21.
HPLC -ARUN NIVAS V PERIYAR COLLEGE OF PHARMACEUTICAL SCIENCES, TRICHY-21.HPLC -ARUN NIVAS V PERIYAR COLLEGE OF PHARMACEUTICAL SCIENCES, TRICHY-21.
HPLC -ARUN NIVAS V PERIYAR COLLEGE OF PHARMACEUTICAL SCIENCES, TRICHY-21.Arun Nivas
 
HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
HIGH PERFORMANCE LIQUID CHROMATOGRAPHYHIGH PERFORMANCE LIQUID CHROMATOGRAPHY
HIGH PERFORMANCE LIQUID CHROMATOGRAPHYDr Duggirala Mahendra
 

Ähnlich wie HPLC ppt 1 BZU.pptx (20)

Royal ppt hplc
Royal ppt hplcRoyal ppt hplc
Royal ppt hplc
 
HPLC
HPLCHPLC
HPLC
 
HPLC
HPLCHPLC
HPLC
 
Chromatography Part-III
Chromatography Part-IIIChromatography Part-III
Chromatography Part-III
 
HPLC
HPLCHPLC
HPLC
 
High pressure liquid chromatography, B.Pharm
High pressure liquid chromatography, B.PharmHigh pressure liquid chromatography, B.Pharm
High pressure liquid chromatography, B.Pharm
 
Hplc by Bachaspati jana
Hplc by  Bachaspati janaHplc by  Bachaspati jana
Hplc by Bachaspati jana
 
High Performance Liquid Chromatography..
High Performance Liquid Chromatography..High Performance Liquid Chromatography..
High Performance Liquid Chromatography..
 
High Performance Liquid Chromatography (HPLC)
High Performance Liquid Chromatography (HPLC)High Performance Liquid Chromatography (HPLC)
High Performance Liquid Chromatography (HPLC)
 
HPLC.pptx
HPLC.pptxHPLC.pptx
HPLC.pptx
 
High Performance Liquid Chromatography (HPLC)
High Performance Liquid Chromatography (HPLC)High Performance Liquid Chromatography (HPLC)
High Performance Liquid Chromatography (HPLC)
 
A brief review on development and validation of hplc method.
A brief review on development and validation of hplc method.A brief review on development and validation of hplc method.
A brief review on development and validation of hplc method.
 
HPLC & UPLC omkar.pptx isf college of pharmacy moga
HPLC & UPLC omkar.pptx isf college of pharmacy  mogaHPLC & UPLC omkar.pptx isf college of pharmacy  moga
HPLC & UPLC omkar.pptx isf college of pharmacy moga
 
Hplc doc
Hplc docHplc doc
Hplc doc
 
High Performance Liquid Chromatography
High Performance Liquid ChromatographyHigh Performance Liquid Chromatography
High Performance Liquid Chromatography
 
HIGH PERFORMANCE LIQUID CHROMATOGRAPHY/SAGAR/SHARMA/DEPARTMENT OF PHARMACEUTI...
HIGH PERFORMANCE LIQUID CHROMATOGRAPHY/SAGAR/SHARMA/DEPARTMENT OF PHARMACEUTI...HIGH PERFORMANCE LIQUID CHROMATOGRAPHY/SAGAR/SHARMA/DEPARTMENT OF PHARMACEUTI...
HIGH PERFORMANCE LIQUID CHROMATOGRAPHY/SAGAR/SHARMA/DEPARTMENT OF PHARMACEUTI...
 
HPLC
HPLC HPLC
HPLC
 
High performance liquid chromatography
High performance liquid chromatographyHigh performance liquid chromatography
High performance liquid chromatography
 
HPLC -ARUN NIVAS V PERIYAR COLLEGE OF PHARMACEUTICAL SCIENCES, TRICHY-21.
HPLC -ARUN NIVAS V PERIYAR COLLEGE OF PHARMACEUTICAL SCIENCES, TRICHY-21.HPLC -ARUN NIVAS V PERIYAR COLLEGE OF PHARMACEUTICAL SCIENCES, TRICHY-21.
HPLC -ARUN NIVAS V PERIYAR COLLEGE OF PHARMACEUTICAL SCIENCES, TRICHY-21.
 
HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
HIGH PERFORMANCE LIQUID CHROMATOGRAPHYHIGH PERFORMANCE LIQUID CHROMATOGRAPHY
HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
 

Kürzlich hochgeladen

Formation of low mass protostars and their circumstellar disks
Formation of low mass protostars and their circumstellar disksFormation of low mass protostars and their circumstellar disks
Formation of low mass protostars and their circumstellar disksSérgio Sacani
 
Pests of cotton_Borer_Pests_Binomics_Dr.UPR.pdf
Pests of cotton_Borer_Pests_Binomics_Dr.UPR.pdfPests of cotton_Borer_Pests_Binomics_Dr.UPR.pdf
Pests of cotton_Borer_Pests_Binomics_Dr.UPR.pdfPirithiRaju
 
Hire 💕 9907093804 Hooghly Call Girls Service Call Girls Agency
Hire 💕 9907093804 Hooghly Call Girls Service Call Girls AgencyHire 💕 9907093804 Hooghly Call Girls Service Call Girls Agency
Hire 💕 9907093804 Hooghly Call Girls Service Call Girls AgencySheetal Arora
 
TEST BANK For Radiologic Science for Technologists, 12th Edition by Stewart C...
TEST BANK For Radiologic Science for Technologists, 12th Edition by Stewart C...TEST BANK For Radiologic Science for Technologists, 12th Edition by Stewart C...
TEST BANK For Radiologic Science for Technologists, 12th Edition by Stewart C...ssifa0344
 
VIRUSES structure and classification ppt by Dr.Prince C P
VIRUSES structure and classification ppt by Dr.Prince C PVIRUSES structure and classification ppt by Dr.Prince C P
VIRUSES structure and classification ppt by Dr.Prince C PPRINCE C P
 
Spermiogenesis or Spermateleosis or metamorphosis of spermatid
Spermiogenesis or Spermateleosis or metamorphosis of spermatidSpermiogenesis or Spermateleosis or metamorphosis of spermatid
Spermiogenesis or Spermateleosis or metamorphosis of spermatidSarthak Sekhar Mondal
 
Pests of cotton_Sucking_Pests_Dr.UPR.pdf
Pests of cotton_Sucking_Pests_Dr.UPR.pdfPests of cotton_Sucking_Pests_Dr.UPR.pdf
Pests of cotton_Sucking_Pests_Dr.UPR.pdfPirithiRaju
 
GBSN - Biochemistry (Unit 1)
GBSN - Biochemistry (Unit 1)GBSN - Biochemistry (Unit 1)
GBSN - Biochemistry (Unit 1)Areesha Ahmad
 
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...Sérgio Sacani
 
GFP in rDNA Technology (Biotechnology).pptx
GFP in rDNA Technology (Biotechnology).pptxGFP in rDNA Technology (Biotechnology).pptx
GFP in rDNA Technology (Biotechnology).pptxAleenaTreesaSaji
 
Lucknow 💋 Russian Call Girls Lucknow Finest Escorts Service 8923113531 Availa...
Lucknow 💋 Russian Call Girls Lucknow Finest Escorts Service 8923113531 Availa...Lucknow 💋 Russian Call Girls Lucknow Finest Escorts Service 8923113531 Availa...
Lucknow 💋 Russian Call Girls Lucknow Finest Escorts Service 8923113531 Availa...anilsa9823
 
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCRStunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCRDelhi Call girls
 
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...Sérgio Sacani
 
Chemistry 4th semester series (krishna).pdf
Chemistry 4th semester series (krishna).pdfChemistry 4th semester series (krishna).pdf
Chemistry 4th semester series (krishna).pdfSumit Kumar yadav
 
Animal Communication- Auditory and Visual.pptx
Animal Communication- Auditory and Visual.pptxAnimal Communication- Auditory and Visual.pptx
Animal Communication- Auditory and Visual.pptxUmerFayaz5
 
DIFFERENCE IN BACK CROSS AND TEST CROSS
DIFFERENCE IN  BACK CROSS AND TEST CROSSDIFFERENCE IN  BACK CROSS AND TEST CROSS
DIFFERENCE IN BACK CROSS AND TEST CROSSLeenakshiTyagi
 
Traditional Agroforestry System in India- Shifting Cultivation, Taungya, Home...
Traditional Agroforestry System in India- Shifting Cultivation, Taungya, Home...Traditional Agroforestry System in India- Shifting Cultivation, Taungya, Home...
Traditional Agroforestry System in India- Shifting Cultivation, Taungya, Home...jana861314
 
Cultivation of KODO MILLET . made by Ghanshyam pptx
Cultivation of KODO MILLET . made by Ghanshyam pptxCultivation of KODO MILLET . made by Ghanshyam pptx
Cultivation of KODO MILLET . made by Ghanshyam pptxpradhanghanshyam7136
 
Nightside clouds and disequilibrium chemistry on the hot Jupiter WASP-43b
Nightside clouds and disequilibrium chemistry on the hot Jupiter WASP-43bNightside clouds and disequilibrium chemistry on the hot Jupiter WASP-43b
Nightside clouds and disequilibrium chemistry on the hot Jupiter WASP-43bSérgio Sacani
 

Kürzlich hochgeladen (20)

Formation of low mass protostars and their circumstellar disks
Formation of low mass protostars and their circumstellar disksFormation of low mass protostars and their circumstellar disks
Formation of low mass protostars and their circumstellar disks
 
Pests of cotton_Borer_Pests_Binomics_Dr.UPR.pdf
Pests of cotton_Borer_Pests_Binomics_Dr.UPR.pdfPests of cotton_Borer_Pests_Binomics_Dr.UPR.pdf
Pests of cotton_Borer_Pests_Binomics_Dr.UPR.pdf
 
The Philosophy of Science
The Philosophy of ScienceThe Philosophy of Science
The Philosophy of Science
 
Hire 💕 9907093804 Hooghly Call Girls Service Call Girls Agency
Hire 💕 9907093804 Hooghly Call Girls Service Call Girls AgencyHire 💕 9907093804 Hooghly Call Girls Service Call Girls Agency
Hire 💕 9907093804 Hooghly Call Girls Service Call Girls Agency
 
TEST BANK For Radiologic Science for Technologists, 12th Edition by Stewart C...
TEST BANK For Radiologic Science for Technologists, 12th Edition by Stewart C...TEST BANK For Radiologic Science for Technologists, 12th Edition by Stewart C...
TEST BANK For Radiologic Science for Technologists, 12th Edition by Stewart C...
 
VIRUSES structure and classification ppt by Dr.Prince C P
VIRUSES structure and classification ppt by Dr.Prince C PVIRUSES structure and classification ppt by Dr.Prince C P
VIRUSES structure and classification ppt by Dr.Prince C P
 
Spermiogenesis or Spermateleosis or metamorphosis of spermatid
Spermiogenesis or Spermateleosis or metamorphosis of spermatidSpermiogenesis or Spermateleosis or metamorphosis of spermatid
Spermiogenesis or Spermateleosis or metamorphosis of spermatid
 
Pests of cotton_Sucking_Pests_Dr.UPR.pdf
Pests of cotton_Sucking_Pests_Dr.UPR.pdfPests of cotton_Sucking_Pests_Dr.UPR.pdf
Pests of cotton_Sucking_Pests_Dr.UPR.pdf
 
GBSN - Biochemistry (Unit 1)
GBSN - Biochemistry (Unit 1)GBSN - Biochemistry (Unit 1)
GBSN - Biochemistry (Unit 1)
 
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
 
GFP in rDNA Technology (Biotechnology).pptx
GFP in rDNA Technology (Biotechnology).pptxGFP in rDNA Technology (Biotechnology).pptx
GFP in rDNA Technology (Biotechnology).pptx
 
Lucknow 💋 Russian Call Girls Lucknow Finest Escorts Service 8923113531 Availa...
Lucknow 💋 Russian Call Girls Lucknow Finest Escorts Service 8923113531 Availa...Lucknow 💋 Russian Call Girls Lucknow Finest Escorts Service 8923113531 Availa...
Lucknow 💋 Russian Call Girls Lucknow Finest Escorts Service 8923113531 Availa...
 
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCRStunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
 
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
 
Chemistry 4th semester series (krishna).pdf
Chemistry 4th semester series (krishna).pdfChemistry 4th semester series (krishna).pdf
Chemistry 4th semester series (krishna).pdf
 
Animal Communication- Auditory and Visual.pptx
Animal Communication- Auditory and Visual.pptxAnimal Communication- Auditory and Visual.pptx
Animal Communication- Auditory and Visual.pptx
 
DIFFERENCE IN BACK CROSS AND TEST CROSS
DIFFERENCE IN  BACK CROSS AND TEST CROSSDIFFERENCE IN  BACK CROSS AND TEST CROSS
DIFFERENCE IN BACK CROSS AND TEST CROSS
 
Traditional Agroforestry System in India- Shifting Cultivation, Taungya, Home...
Traditional Agroforestry System in India- Shifting Cultivation, Taungya, Home...Traditional Agroforestry System in India- Shifting Cultivation, Taungya, Home...
Traditional Agroforestry System in India- Shifting Cultivation, Taungya, Home...
 
Cultivation of KODO MILLET . made by Ghanshyam pptx
Cultivation of KODO MILLET . made by Ghanshyam pptxCultivation of KODO MILLET . made by Ghanshyam pptx
Cultivation of KODO MILLET . made by Ghanshyam pptx
 
Nightside clouds and disequilibrium chemistry on the hot Jupiter WASP-43b
Nightside clouds and disequilibrium chemistry on the hot Jupiter WASP-43bNightside clouds and disequilibrium chemistry on the hot Jupiter WASP-43b
Nightside clouds and disequilibrium chemistry on the hot Jupiter WASP-43b
 

HPLC ppt 1 BZU.pptx

  • 1. HIGH PERFORMANCE LIQUID CHROMATOGRAPHY [HPLC] Mr. Khalid Nadeem Blouch Mr. Muhammad illyas Mr. Muhammad Haris [Department of chemistry (Physical chem)] 1 Institute of chemical sciences ( BZU) Multan 25.03.2023
  • 2. CHROMATOGRAPHY  It is define as an analytical method in which separation of active constituent in complex mixture, which was distributed in two phases i.e. stationary phase and mobile phase is known as chromatography.
  • 3. Use of CHROMATOGRAPHY  This technique is used for 1. separation, 2
  • 4. Use of CHROMATOGRAPHY  This technique is used for 1. separation, 2. purification, 2
  • 5. Use of CHROMATOGRAPHY  This technique is used for 1. separation, 2. purification, 3. Identification and 2
  • 6. Use of CHROMATOGRAPHY  This technique is used for 1. separation, 2. purification, 3. Identification and 4. extraction of compound.  Details of its application will be discussed at the end 2
  • 7. Some definitions  Stationary phase is constant phase or column packaging material.  Mobile phase is moveable phase.  The basic principle of chromatography is based on Adsorption and partition chromatography.  Adsorption chromatography - The affinity of molecules towards stationary phase is known as Adsorption chromatography.  Partition chromatography - The molecule can moves in two phases of liquid is known as partition chromatography.  Qualitative Analysis: identification of the constituents  Quantitative analysis. Quantification of the constituents
  • 8. TYPES OF CHROMATOGRAPHY  Based on modes of chromatography 1. Normal phase mode 2.Reverse phase mode  Based on principle of separation 1. Adsorption chromatography 2. Ion exchange chromatography 3. Partition chromatography 4. Size exclusion  Based on elution technique 1. Isocratic separation 2. Gradient separation  Based on the scale of operation 1. Analytical HPLC 2. Preparative HPLC  Based on the type of analysis 1. Qualitative analysis 2. Quantitative analysis 3
  • 9. PRINCIPLES OF LIQUID CHROMATOGRAPHY 9
  • 10. TYPES OF LIQUID CHROMATOGRAPHY 1 0
  • 11. HPLC 1 1  HPLC is a High Performance liquid Chromatography.  High Pressure Liquid Chromatography.  High Priced Liquid Chromatography.  It is column chromatography.  It is Liquid Chromatography.  It is modified from of gas chromatography, it is applicable for both Volatile as well as Non volatile compound.  It can mainly divided by two types 1. Normal phase HPLC 2. Reversed Phase HPLC.  It is having a high resolution and separation capacity.  It is used as qualitative as well as quantitative analysis.  High performance liquid chromatography (HPLC) is a chromatographic technique used to separate a mixture of compounds in analytical chemistry and biochemistry with the purpose of identifying, quantifying or purifying the individual components of the mixture.
  • 12. 1 2
  • 13. PRINCIPLE 1 3  High Performance Liquid Chromatography [HPLC] is principle is based on adsorption as well as partition chromatography is depending on the nature of stationary phase, if stationary phase is solid principle is based on adsorption chromatography and if stationary phase is liquid principle is based on partition chromatography.  It is important for determination of volatile and non volatile compounds.  It is important for determination qualitative and quantitative analysis.  It is important for determination of Retention Time (the time is required , after sample injection maximum angle peak reaches to detector)
  • 14. 1 4
  • 15. ADVANTAGES  It is simple, rapid , reproducible.  High sensitivity.  High performance.  Rapid process and hence time saving.  It is having a high resolution and separation capacity.  Accuracy and Precision.  Stationary phase was chemically innert.  Wide varities of stationary phase.  Mobile phase was chemically innert.  Less requirement of mobile phase in developing chamber.  Early recovery of separated component.  Easy visualization of separated components.  It is having Good reproducibility and repeatability.  It is analytical technique is important for validation of product, quality control studies of product.  It is important for qualitative and quantitative analysis.  It is used for both analytical and preparative purpose. 10
  • 16. TYPES OF HPLC SEPARATIONS 16  Normal Phase: Separation of polar analytes by partitioning onto a polar, bonded stationary phase.  Reversed Phase: Separation of non-polar analytes by partitioning onto a non-polar, bonded stationary phase.  Adsorption: In Between Normal and Reversed. Separation of moderately polar analytes using adsorption onto a pure stationary phase (e.g. alumina or silica)  Ion Chromatography: Separation of organic and inorganic ions by their partitioning onto ionic stationary phases bonded to a solid support.  Size Exclusion Chromatography: Separation of large molecules based in the paths they take through a “maze” of tunnels in the stationary phase.
  • 17. HPLC METHODS 17  Parameter Group Method Compounds • SDW05.23000’s EPA555 Cl-PhenoxyAcids • WPP05.06000’s EPA605 Benzidines • WPP05.13000’s EPA610 PAHs • SHW06.26000’s SW-846 8316 Acrylics • SHW06.28000’s SW-846 8330’s Explosives • SHW07.06000’s SW-846 8325 Benzidines and N- Pesticides
  • 18. MODES OF HIGH PERFORMANCE LIQUID CHROMATOGRAPHY 13 Types of Compounds Mode Stationary Phase Mobile Phase Neutrals Weak Acids Weak Bases Reversed Phase C18, C8, C4 cyano, amino Water/Organic Modifiers Ionics, Bases,Acids Ion Pair C-18, C-8 Water/Organic Ion-Pair Reagent Compounds not soluble in water Normal Phase Silica,Amino, Cyano, Diol Organics Ionics Inorganic Ions Ion Exchange Anion or Cation Exchange Resin Aqueous/Buffer Counter Ion High Molecular Weight Compounds Polymers Size Exclusion Polystyrene Silica Gel Filtration- Aqueous Gel Permeation- Organic
  • 19. HPLC CONTAIN  Stationary Phase - It is non polar and The stationary solid surface is coated with a 2nd liquid (the Stationary Phase) which is immiscible with mobile phase.  Mobile Phase - A polar mobile phase(ACN, MeOH, WATER + BUFFER). Bonded Phases - 19 -Si-(CH2)3-CN -Si-(CH2)17-CH3  C-2 Ethyl Silyl • C-8 Octyl Silyl • C-18 Octadecyl Silyl • CN Cyanopropyl Silyl -Si-CH2-CH3 -Si-(CH2)7-CH3
  • 20. BLOCK DIAGRAM OF HPLC 20 Reservoir Pump Gradient controller Mixing chamber Pump Solvent Conditioning column Reservoir Injector Precolumn Analytical column Detector Recorder Fraction collector
  • 21. WHY USE HPLC 21  Simultaneous analysis  High resolution  High sensitivity  Good repeatability  Moderate analysis condition  Easy to fractionate and purify  Not destructive
  • 22. INSTRUMENTATION OF HPLC 22  Solvent storage bottle  Gradient controller and mixing unit  De-gassing of solvents  Pump  Pressure gauge  Pre-column  Sample introduction system  Column  Detector  Recorder
  • 23. 23
  • 24. 24
  • 25. 25
  • 26. 26
  • 27. 27
  • 28. 23 23 OUTLINE OF LC-2010 System Controller UV detector Auto sampler Column Oven Pump Unit Reservior Tray Degassing Unit Low pressure gradient device
  • 29. 24 HPLC SYSTEM 9010 Solvent Delivery System 9050 Variable UV/Vis Detector HPLC Solvent Reservoirs HPLC Column Rheodyne Injector 9060 Polychrom (Diode Array) Detector Computer Workstation
  • 30. SOLVENT/ MOBILE PHASE RESERVOIRS  Glass or stainless-steel containers capable of holding up to 1 liter mobile phase (pure organic solvents or aqueous solutions of salts and buffers)  Inert to a variety of aqueous and non aqueous mobile phases.  Stainless steel should be avoided for use with solvents containing halide ions. 25
  • 31. DEGASSING & FILTRATION OF MOBILE PHASE  In many cases, aqueous solvents & some organic solvents are degassed prior to use  Degassing is done to prevent formation of gas bubbles in the pump or detector ( Mobile phases are degassed by stirring of the mobile phase under vacuum, sonication or sparing with helium gas)  The mobile phase are filtered to remove particulate matter that may clog the system Tubing  Should be inert,  have ability to withstand pressure  able to carry sufficient volume 26
  • 32. PUMP 32  The solvents or mobile phase must be passed through a column at high pressures at up to 6000 psi(lb/in²) or 414 bar.  As the particle size of stationary phase is smaller (5 to 10µ) the resistance to the flow of solvent will be high.  That is, smaller the particle size of the stationary phase the greater is the resistance to the flow of solvents.  Hence high pressure is recommended.
  • 33. REQUIREMENTS FOR PUMPS 33  Generation of pressure of about 6000 psi.  Pulse free output & all materials in the pump should be chemically resistant to solvents.  Flow rates ranging from 0.1 to 10 mL/min  Pumps should be capable of taking the solvent from a single reservoir or more than one reservoir containing different solventssimultaneously.
  • 34. Types of pumps used in HPLC 34 DISPLACEMENT PUMPS RECIPROCATING PUMPS PNEUMATIC PUMPS
  • 35. HPLC Pump Constant flow rate (Mechanical) Pump Constant Pressure Pump (Pneumatic) Manner in which they operate syringe (Displace ment pump) Reciprocating pump Single piston reciprocati ng pump Double piston reciprocating pump Reciprocating diaphragm pump Direct pressure pump Amplifier pump 35
  • 36. DISPLACEMENT PUMPS 36 It consists of large, syringe like chambers equipped with a plunger activated by a screw driven mechanism powered by a stepping motor. So it is also called as Screw Driven Syringe Type Pump. Advantages:- It produces a flow that tends to be independent of viscosity & back pressure. Disadvantages:- It has a limited solvent capacity(~250) & considerably inconvenient when solvents must be changed.
  • 37. 37
  • 38. RECIPROCATING PUMPS  This pump transmits alternative pressure to the solvent via a flexible diaphragm ,which in turn is hydraulically pumped by a reciprocating pump.  Disadvantages Produces a pulsed flow which is damped because pulses appear as baseline noise on the chromatograph. This can be overcome by use of dual pump heads or elliptical cams to minimize such pulsations. 33
  • 39. motor and cam plunger check valve pump head 5 - 50µL out plunger seal in Mobile phase check valve 39
  • 40.  Solvent is pumped back and forth by a motor driven piston  Two ball check valves which open & close which controls the flow  The piston is in direct contact with the solvent  Small internal volume 35-400μL  High output pressure up to 10,000 psi  Ready adaptability to gradient elution and constant flow rate 40
  • 41. 36 A. Single-piston pump with slow filling cycle B. Single-piston pump with a rapid filling cycle C.Adual-piston pump with rapid filling cycles and operate 1800 out of phase. Schematic representation of solvent flow from
  • 42.  Advantages  Have small internal volume of 35-400µL  Higher output pressures up to 10,000 psi.  Adaptability to gradient elution.  Large solvent capacities & constant flow rates.  Largely independent of column back pressure & solvent viscosity. 42
  • 43. PNEUMATIC PUMPS 43  In this pumps, the mobile phase is driven through the column with the use of pressure produced from a gas cylinder.  It has limited capacity of solvent  Due to solvent viscosity back pressure may develop.
  • 44. SAMPLE INJECTOR SYSTEM 44  Several injector devices are available either for manual or auto injection of the sample. (i) Septum Injector (ii) Stop Flow Injector (iii) Rheodyne Injector
  • 45. i. SEPTUM INJECTOR 45 These are used for injecting the sample through a rubber septum. This kind of injectors cannot be commonly used , since the septum has to withstand high pressures. ii. Stop Flow  In this type the flow of mobile phase is stopped for a while & the sample is injected through a valve.
  • 46. III. RHEODYNE INJECTOR 46  It is the most popular injector and is widely used.  This has a fixed volume of loop, for holding sample until its injected into the column, like 20µL, 50µL or more.  Through an injector the sample is introduced into the column.  The injector is positioned just before the inlet of the column.
  • 47. 47
  • 48. SELECTION VALVE BY USING THE SELECTION VALVE WE CAN SELECT WHETHER THE PURPOSE IS FOR ANALYTICAL PURPOSE OR PREPARATIVE PURPOSE. INJECT POSITION In this position the loaded sample is injected into the column by the forceful flow of the solvent into the sample loop by which the sample is introduced into the column. LOAD POSITION In this position the sample is loaded into the sample loop . 43 43
  • 50. COLUMN 1. Precolumn 1. It contains a packing chemically identical to that in analytical column. 2.Mainly used to remove the impurities from the solvent and thus prevents contamination of the analytical column, it can protect analytical column. 3. It is also called as guard column or protective column. 4. it is having large particle size. 5. It is having short length of 2 to 10 cm, so does not affect separation. 2. Analytical column 1. The success or failure of analysis depends upon choice of column. 2. Actual separation is carried out here. 3. Stainless –steel tube 4. size – length -25 to 100 cm 5. Internal diameter – 2 to 4.6 mm 6. Column is filled with small particles 5 – 10 micron. The solid support can be silica gel, alumina. 7. The separation is result of different components adhering to or diffusion into the packing particles when the mobile phase is forced through column. 45
  • 51. 8.C8 and C18 columns are considered as examples of reversed phase liquid chromatography (RP). 9.The stationary phase here is seen as a thin film of non-polar liquid phase that has been designed to be chemically similar to an inert material (Silica gel particles). 10.The non-polar layer is chemically linked to the silica particles surface by reaction with the polar silanol groups on the stationary phase surface and so rendering them less polar or non-polar. 11. The difference between the two columns will be in the length of the carbon- chain attached to the silica surface. 12.Accordingly C8 hplc columns have packing material composed of silica particles attached to C8 carbon units. 13. C18 will, of course, have packing materials coated with C18 hydrophobic units. 14.Categorically both are reversed phase but C18 columns will definitely be more "hydrophobic rather than the C8 columns. 51
  • 52. DETECTORS 52  Absorbance (UV/Vis and PDA)  Refractive index (detects the change in turbidity)  Fluorescence (if the analyte is fluorescent)  Electrochemical (measures current flowing through a pair of electrodes, on which a potential difference is imposed, due to oxidation or reduction of solute)  Conductivity (for ions)  Light scattering  Mass spectrometry (HPLC-MS)
  • 53. SELECTION OF DETECTORS  Compounds with chromophores, such as aromatic rings multiple alternating double bonds.  Fluorescent compounds, usually with fused rings or high conjugated planar system.  Charged compounds, such as inorganic ions and organi acid. 53 Detectors Type of compounds can be detected UV-Vis & PDA RF CDD ECD For easily oxidized compounds like quinones or amines. RID & ELSD For compounds that do not show characteristics usable by the other detectors, e.g. polymers, saccharides.
  • 54. TYPES OF HPLC DETECTORS UV-Vis Works w/all molecules Non-specific; complex samples; absorption wavelength DAD Works for all wavelengths High LOD Fluorescence Very specific; low LOD Not everything fluoresces IR Works w/all molecules Many solvents IR active Refractive Index Works w/nearly all molecules Temperature sensitive; high LOD Scattering Uniform response; 5ng/25mL LOD Non-specific; interference from solvent Electrochemical Commercially available Non-specific; high LOD Mass Spec Low LOD; analyte identification Ability to ionize analyte 49 Name Advantage Disadvantage
  • 55. IDEAL DETECTOR PROPERTIES 55  High Sensitivity  Universality or predictable specificity  Large linear response range  Low dead volume  Non-Destructive  Insensitive to temperature & mobile phase  Continuous operation  Reliable and easy to use  No single detector fits all these criteria
  • 56. UV-VISIBLE DETECTOR 56  UV visible detector is widely used as it detects large number of compounds because most drugs have appropriate structural characteristics for light absorption.  These are useful for aromatic compounds and other type of unsaturatedsystems.  These are classified as fixed or variable wavelength detectors.  Fixed wavelength detectors employ filter as a source to provide appropriate wavelength.  Most common fixed wavelength detectors are based on 254 nm.  Variable wavelength detectors are employ a spectrophotometer to provide dispersion of light and selection of any wavelength in UV visibleregions.  Diffraction gratings are frequently used for wavelengthdispersion.
  • 57. 57
  • 58. REFRACTIVE INDEX (RI) DETECTOR 58  Detection occurs when the light is bent due to samples eluting from the columns, and this is read as a disparity b/w the two channels.  It is not much used for analytical applications because of low sensitivity & specificity.  When a solute is in the sample compartment, refractive index changes will shift the light beam from the detector.
  • 59. PHOTODIODE ARRAY (PDA) 59  A photodiode array (PDA) is a linear array of discrete photodiodes on an integrated circuit (IC) chip.  Allows a range of wavelengths to be detected simultaneously. In this regard it can be thought of as an electronic version of photographic film. Array detectors are especially useful for recording the full Uv- vis is a absorption spectra of samples that are rapidly passing through a sample flow cell, such as in an HPLC detector.  PDAs work on the same principle as simple. Photovoltaic detector  similar to UV detector, non destructive 190-600 nm for quantization & identification Spectra is 3D, Response vs time vs WL.
  • 60. FLUORIMETRIC DETECTORS detector while a  It is based on the fluorescent radiation emitted by some compounds.  The excitation source passes through the flow cell to a photo monochromatic measures the emission wavelengths.  More sensitive and specific.  The disadvantage is that most compounds are not fluorescent in nature.  Fluorescence is a type of luminescence in which the light energy is released in the form of a photon in nanoseconds to microseconds. 55 S1 T1 S0 Light absorption Non-radiation transition Non-radiation transition Fluorescence Phosphorescence
  • 61. 61
  • 62. 62
  • 63. RECORDERS AND INTEGRATORS 63  Recorders are used to record responses obtained from the detectors after amplification, if necessary.  They record the baseline & all the peaks obtained with respect tot time.  Retention time can be found out from this recordings, but area under curve cannot be determined.  The Integrators are improved versions of recorders with some data processing capabilities.  They can record the individual peaks with retention time, height, width of peaks, peak area, percentage area, etc.  Integrators provides more information on peaks than recorders.  In recent days computers and printers are used for recording and processing the obtained data & for controlling several operations.
  • 64. COMPARISION BETWEEN HPTLC AND HPLC Sr.no. HPTLC HPLC 1 High Performance Thin Layer High Chromatography Performance Liquid Chromatography 2 Column Chromatography 3 Adsorption Planar Chromatography Principle based on Chromatography Principle is based on Adsorption and Partition Chromatography 4 Simultaneous method for test as well as reference material Not simultaneous method for test as well as reference material 5 It is simple, rapid, reproducible method It is Tedious method 6 Sample preparation is simple Sample preparation is complex 7 Limited Flexibility Extreme Flexibility 8 Semiautomatic Technique Automatic (Instrumental) Technique 59 9 Determination of SurfaceArea Determination of Retention Time
  • 65. COMPARISION BETWEEN GC AND HPLC 60 SR.NO. GC HPLC 1 Gas Chromatography High Performance Liquid Chromatography 2 Less resolution High resolution 3 Limited Flexibility Extreme Flexibility 4 Determination of Volatile compounds Determination of Volatile and Non Volatile Compounds
  • 66. COMPARISION BETWEEN HPLC AND UPLC Parameters HPLC Assay UPLC Assay Column XTerra,C18,50 × 4.6mm AQUITY UPLC BEH C18,50 ×2.1mm Particle size 4µm particles 1.7µm particles Flow rate 3.0 ml per min 0.6 ml per min Injection volume 20 µl 3 µl partial loop fill or 5 µl full loop fill Total run time 10 min 1.5 min Theoretical Plate 2000 7500 count 61
  • 67. 62 Parameters HPLC Assay UPLC Assay Lower limit of quantization 0.2 µg/ml 0.054µl/ml Total solvent consumption Acetonitrile:10.5ml, water:21ml Acetonitrile:0.53ml, water:0.66ml Delay volume 720 µl 110 µl Column temperature 30 °C 65 °C Maximum back pressure 35-40 Mpa less 103.5 Mpa more Resolution Less High Method development cost High Low
  • 68. APPLICATION  Drug Discovery  ClinicalAnalysis  Proteomics  Forensic Chemistry  Drug Metabolism study  Environmental chemistry  Diagnostic studies  Cosmetic analysis  Determination of Green Florescent Protein  Structural Determination  PharmaceuticalApplications  Identification of Bile Acid Metabolite  ClinicalApplications  Biochemical Genetics  qualitative and quantitative analysis  Therapeutic Drug Monitoring 63
  • 69. REFERENCE  Knox JH, DoneJN, Fell AF et al. High-Performance Liquid Chromatography. Edinburgh: Edinburgh University Press; 1978.  Simpson CF. Practical High-Performance Liquid Chromatography. London: Heyd and Son; 1976.  Pungor E. A Practical Guide to Instrumental Analysis. Boca Raton: CRC Press; 19  Moffat AC, Osselton MD, Widdop B. Clarke’s Analysis of Drugs and Poisons. Lon Pharmace utical Press; 2004.  Y. Shen and R.D. Smith, Electrophoresis 23 (2002) pp. 3106-3124.  D.A. Skoog and D.M. West, Fundamentals of Analytical Chemistry, 3rd edit., pp. 64  D. Sievers, M.E. Swartz and B.J. Murphy, G.I.T. Laboratory Journal(2004) pp.43 45.(2004) pp.  503-504  L.A. Colon, J.M. Cintron, J.A. Anspach, A.M. Fermier and K.A. Swinney, The Analy  L.R. Snyder, J.J. Kirkland and J.L. Glajch, Practical HPLC Method development, 2n edit., pp. 41- 43. and J.W. Jorgenson, LCGC 21 (July 2003) pp. 600-611. 64
  • 70. 65