1. Manufacturer of water treatment chemicals like Descalants, Antiscalants Biocides pH boosters and Reducers
and supplier of Water Treatment Plant like RO., DM., and Water Softening Plant ,Resins, Filters, RO
Membranes and other spare parts
To,
Dear Sir,
We have great pleasure to introduce ourselves as one of the leading manufacturers of
Water Treatment Chemicals, supplier of Cooling towers and Water Treatment Plants.
We also undertake job work such as Descaling and AMC's for Boilers, water cooling system.
We manufacture following chemicals:
•
Descalants (strong & mild) for descaling of cooling towers, boilers, chillers etc
•
Antiscalants & Anticorrosive agents for cooling towers, boilers, chillers etc
•
Antialgae (Biocides) to prevent from algae and slum at cooling towers
•
Oxygen Scavenger and pH boosters
•
Antifouling agent to prevent from atmospheric dust particles at cooling towers
•
Cooling Towers
We also supply, repair and undertake AMC's of water treatment plants
•
Water Softening Plant
•
DM Plant
•
RO (Reverse Osmosis) Plant
•
Pressure Sand Filter and Activated Carbon filter
We hope that all your future requirements of above products we shall be in your enlisted records
and invited for a fruitful participation in various projects
In the meanwhile, awaiting for your valued enquiries in case you enquire any further details.
Please feel free to contact us
Thanking you and assuring you of our best services at all times.
Regards
VIJAY JAISWAL
KASHVI CHEMICALS & SERVICES
For more details, Contact at anyone of the offices:
AURANGABAD: A 1 PLOT NO 12 KAPILA HSG SOC N-7 CIDCO, AUARANGABAD –431003
NASIK: 301/305 VIKRANT HAPPY HOMES PRASANNA ARCADE TRIMBAK NAKA NASIK 422001.
Mob: 9923878975, 8888868765
Email: kashvichemicals@gmail.com.
2. Manufacturer of water treatment chemicals like Descalants, Antiscalants Biocides pH boosters and Reducers
and supplier of Water Treatment Plant like RO., DM., and Water Softening Plant ,Resins, Filters, RO
Membranes and other spare parts
OUR PRODUCT RANGES IN WATER TREATMENT
•
Descalants (strong & mild) for descaling of cooling towers, boilers, chillers etc
•
Antiscalants & Anticorrosive agents for cooling towers, boilers, chillers etc
•
Antialgae (Biocides) to prevent from algae and slum at cooling towers
•
Oxygen Scavenger and pH boosters
•
Antifouling agent to prevent from atmospheric dust particles at cooling towers
•
Cooling towers
•
Cooling Tower Fills, Sprinklers and spares
WE ALSO DEAL, REPAIR AND UNDERTAKE AMC'S OF WATER TREATMENT PLANTS
LIKE
Sr. No.
Products
1
COOLING TOWER CHEMICALS
2
ANTISCALING AGENTS
3
DE – SCALING AGENT
4
ANTI ALGAE AGENT
5
BIOCIDES
6
BOILER CHEMICALS
7
WATER TESTING KITS
8
pH METER
9
TDS METER
10
RO CHEMICALS
11
RESINS
12
FILTERS
13
COOLING TOWERS
14
COOLING TOWER FILLS
15
SPRINKLERS
For more details, Contact at anyone of the offices:
AURANGABAD: A 1 PLOT NO 12 KAPILA HSG SOC N-7 CIDCO, AUARANGABAD –431003
NASIK: 301/305 VIKRANT HAPPY HOMES PRASANNA ARCADE TRIMBAK NAKA NASIK 422001.
Mob: 9923878975, 8888868765
Email: kashvichemicals@gmail.com.
3. Manufacturer of water treatment chemicals like Descalants, Antiscalants Biocides pH boosters and Reducers
and supplier of Water Treatment Plant like RO., DM., and Water Softening Plant ,Resins, Filters, RO
Membranes and other spare parts
WHY WATER TREATMENT REQUIRES
Water is nature’s best and most available source of heat transfer for cooling
systems and boilers. Whether of drinking quality or not, any water will produce scales
and corrosion in cooling systems and steam processing units unless properly treated to
prevent harmful effects of the feed water.
SCALE & HARMFUL EFFECTS
Water contains considerable amounts of scale forming constituents , for eg,
Calcium and Magnesium carbonates, sulphates, Magnesium hydroxide, Silica etc. The
scale deposit on metal parts and inside pipeline of heat exchangers, evaporators,
boilers, compressors, solar heaters, Generators, AC units and water cooling circuits.
The adherent scales impede heat transfer capacity of the unit (Heat Conduction
Capacity of hard water scale is only 3.8 % of Steel). Thus, requiring 12 % more fuel
(through 1/16” scale in boiler) to achieve the same heat transfer. In practice, thickness
of the scale may be much higher. In a similar way, scales work as insulation for heat
transfer in exchangers, compressors and generators which result in energy loss and
higher pressure attack, metal failure at hot spots and reduction in the capacity of heat
transfer tubes.
WATER TREATMENT SOLUTIONS
The loss of energy, downtime of various equipments and replacement of
expensive tubes and components can be prevented by periodic scale cleaning.
Mechanical removal of scales involving inaccessible areas of the assembled unit is
difficult. Chemical cleaning is more efficient in these positions.
In addition to scale cleaning, number of Water Treatment compounds
have been formulated to prevent scaling, corrosion and Algae that will keep the
equipment clean and efficient for period of usage.
For more details, Contact at anyone of the offices:
AURANGABAD: A 1 PLOT NO 12 KAPILA HSG SOC N-7 CIDCO, AUARANGABAD –431003
NASIK: 301/305 VIKRANT HAPPY HOMES PRASANNA ARCADE TRIMBAK NAKA NASIK 422001.
Mob: 9923878975, 8888868765
Email: kashvichemicals@gmail.com.
4. Manufacturer of water treatment chemicals like Descalants, Antiscalants Biocides pH boosters and Reducers
and supplier of Water Treatment Plant like RO., DM., and Water Softening Plant ,Resins, Filters, RO
Membranes and other spare parts
OUR PRODUCT RANGE, APPLICATION & METHODS
DESCALING OF BOILERS & COOLING SYSTEMS
PRODUCTS
APPLICATION
DOSAGE
METHADOLOGY
KC 201
Cleaning of boilers’ steam
Processing unit
15% to 20% in
water
Forced circulation in system by pump
10 to 15 hours till scales are removed
KC 203
Cleaning of chiller
15% to 20 % in
water
Forced circulation in system by pump
KC 204
For neutralizing & washing of
system (passivating agent)
3% to 5% in water
Forced circulation in system by pump
for 1 to 2 hours
KC 209
Descaling of water-cooling
System
4% to 5% in water
Forced circulation in system by pump
4 to 6 hours till scales are removed
KC - 205
Descaling of water-cooling
System
5% to 8% in water
Forced circulation in system by pump
5 to 8 hours till scales are removed
BOILER WATER TREATMENT
PRODUCTS
APPLICATION
DOSAGE
METHADOLOGY
KC 701
Single Chemical Treatment
For prevention of scaling &
Corrosion in small boilers
100 to 200 ppm of
make-up water as
recommended
Regular dosing of boiler make-up
water tank
KC 702
Single Chemical Treatment
For prevention of scaling &
Corrosion for other boilers
70 to 150 ppm of
make-up water as
recommended
Regular dosing of boiler make-up
water tank
KC 703
Single Chemical Treatment
For prevention of scaling
150 to 250 ppm as
above
Regular dosing of boiler make-up
water tank
KC 704
Single Chemical Treatment
For prevention of corrosion &
maintain pH boiler’s water
50 to 100 ppm of
make-up water as
recommended
Regular dosing of boiler make-up
water tank
For more details, Contact at anyone of the offices:
AURANGABAD: A 1 PLOT NO 12 KAPILA HSG SOC N-7 CIDCO, AUARANGABAD –431003
NASIK: 301/305 VIKRANT HAPPY HOMES PRASANNA ARCADE TRIMBAK NAKA NASIK 422001.
Mob: 9923878975, 8888868765
Email: kashvichemicals@gmail.com.
5. Manufacturer of water treatment chemicals like Descalants, Antiscalants Biocides pH boosters and Reducers
and supplier of Water Treatment Plant like RO., DM., and Water Softening Plant ,Resins, Filters, RO
Membranes and other spare parts
COOLING WATER TREATMENT
PRODUCTS
APPLICATION
DOSAGE
KC 202
(Antifouling)
To Settle Atmospheric Dust in
Cooling Tower Tank
100 to 200 PPM of
makeup water
Addition in cooling water reservoir
with pH adjustment
KC 601
Single Chemical Treatment
for the small cooling system
preventing scale only
200 to 300 ppm of
make-up water
Clean the water tank & add KC601 at
regular intervals with adjustment of
pH in system
KC 602
Single Chem. Treatment for
raw water recirculation
system preventing scale &
corrosion
100 to 150 ppm of
make-up water
Addition in cooling water reservoir
with pH adjustment
KC 603
Single Chem. Treatment for
soft water recirculation
system preventing scale &
corrosion
50 to 100 ppm of
make-up water
Addition in the cooling water tank with
pH adjustment
KC 604
Specially designed
formulation for prevention of
scaling and corrosion
(Chillers etc)
5 to 20 % of makeup water
KC 605
Prevention of Algae & Slime
Initial dose of 200
ppm
Shock doses at intervals of one
For cooling water tanks
followed by 100
ppm make-up
water
Shock doses at intervals of one week
KC 606
(Biocide)
METHADOLOGY
Dosing to full coolant upto
recommended mark
Refill the whole water with contents
250 hours of running
For more details, Contact at anyone of the offices:
AURANGABAD: A 1 PLOT NO 12 KAPILA HSG SOC N-7 CIDCO, AUARANGABAD –431003
NASIK: 301/305 VIKRANT HAPPY HOMES PRASANNA ARCADE TRIMBAK NAKA NASIK 422001.
Mob: 9923878975, 8888868765
Email: kashvichemicals@gmail.com.