Diese Präsentation wurde erfolgreich gemeldet.
Wir verwenden Ihre LinkedIn Profilangaben und Informationen zu Ihren Aktivitäten, um Anzeigen zu personalisieren und Ihnen relevantere Inhalte anzuzeigen. Sie können Ihre Anzeigeneinstellungen jederzeit ändern.

Water Leak Detection Systems

89 Aufrufe

Veröffentlicht am

Prosino Group focus on Environmental Monitoring Solutions,
See what we could provide:
1)Focus on high spec Water Leak Detection Controllers and Cables(Position&Non-position models).
2)Quick response,24 hours customer service.
3)Excellent pre-sale and after-sale service upon your location.
4)OEM color and length customizing service.

Veröffentlicht in: Umweltschutz
  • Hi there! Essay Help For Students | Discount 10% for your first order! - Check our website! https://vk.cc/80SakO
       Antworten 
    Sind Sie sicher, dass Sie …  Ja  Nein
    Ihre Nachricht erscheint hier

Water Leak Detection Systems

  1. 1. Prosino International Limited Contct: Mr Johnny Tsai Tel:+86 28219561 Email: johnny@prosinogroup.com Web: http://prosinogroup.com/ Information about Water Leakage Detection Systems. Most of water leakage occours indoor or outdoor. The indoor applications such as : 1) Airport 2) Bank 3) Church 4) Clean Room 5) Correctional Facilities 6) Hospital 7) Hotel 8) Medical Facilities 9) Nursing Homes 10) Office Building 11) Residential Facilities 12) Retail 13) Residential 14) School 15) Telecommunication 16) Theater 17) University 18) Warehouse and other places. The outdoor applications : most of water leakage happening is piping system. We are good at indoor water leakage detecting,our company Prosino Group’s mission is try to make the world a safer place. Not only in EU and USA . But also in all of the world . Water sensing cable or water leakage detection cable was widely used in environment monitoring system. It is specially in server room,data center and water tank and more. Now I am here to introduce the product range of Water Leak Detection Cables. There are 2 styles of water leak detection cable. 1) Postition Model P-LFP1000-->which we called Addressable (position) Water Leak Detection model,main features: A) Each meter with 13 ohm resistance . B) The diameter is 6.0mm. C) 4 wires water sensing cable . D) The color could be customized except 2 black sensing wires. E) Length could be customized according to request--We’ll suggest 10meters,15meters,20meters The functions per each wire as below photo show:
  2. 2. Prosino International Limited Contct: Mr Johnny Tsai Tel:+86 28219561 Email: johnny@prosinogroup.com Web: http://prosinogroup.com/ 2) Non-position Model P-LFP1B-->Which we called Non-position or Non-locating model water leak detection model With main features: A) The diameter is 6.0mm or 4.5mm. B) 2 wires water leakage detecting cable. F) The color could be customized except 2 black sensing wires. C) The length could be customized according to the request. The functions per each wire as below photo show: Here I’d like to introduce the Liquid Leakage Detector ( Controller Alarm) There are also 2 versions too 3) Position Controller Alarm P-LFP1-->Position controller,it’s able to detect the leakage distance as long as 1,000 meters, And the tolerance is 0.5%. it has RS485 output and switch output A ) It is for Position Water Leaks detecting. B) It is with RS485 and switch output . RS485 output,which is communicating with computer or monitoring host . It is always with 2 RS485 connectors,1 pair for input;another pair for output(if you would like to Combine with more RS485 devices),switch output,which is communicating with other equipment. C) Tolerance is 0.5%. D) Power supply :Voltage Requested from DC 5V~24V. E) There are 3 LED lights. Power-- It is power light . Service-- It means breaking. Or the cable did not connected well. Leak--When the leakage is happening,the light flashes. F) RS485 . B- A+ B- A+ . It is 2 pairs of RS485 connectors . G) Alarm Replay . It is switch output only available with the device.which power is between 5V- 24V . It is with N.O/N.C COM. It is always only connect 2 cable,the method as below : N. O. and COM or N.C. and COM .
  3. 3. Prosino International Limited Contct: Mr Johnny Tsai Tel:+86 28219561 Email: johnny@prosinogroup.com Web: http://prosinogroup.com/ Power of both of N.O. and N.C. device is between 5V-24V . H)When the cable detected the leakage is happening . After you push the “confirm “ button . The “ leak” led light will turn off . And the leakage position will bed disappeared . So please record the leakage position and inform the staff to handle the leakage before you push “ confirm” button . When you push the second time “ confirm “ button,It is normal working. Here is the photo illustration as below:
  4. 4. Prosino International Limited Contct: Mr Johnny Tsai Tel:+86 28219561 Email: johnny@prosinogroup.com Web: http://prosinogroup.com/ 4)Non-position Controller Alarm P-FP1A -->Non-position(Non-locating) Controller Sensor,Non position water leak detector. A) The sensitive button --There are 3 models of sensitive . Low , Middle, High . B) This model is single way non position water leak detector . C) VCC and GND-- It is for power,VCC means V+, GND means V- . D) RS+/RS- --Please make sure it is correct connection. Here is the completed connecting solution as below: Totally speaking . Position Water Leak Detection System. Power supply (5V-24V) + Position detecting alarm +Lead cable + addressable water sensing cable +clearing end. Non-position Water leakage Detect System. Power supply (5V-24V) + non position detecting alarm +Lead cable + water sensing cable + terminal

×