1. Single Phase Pad-Mounted
Distribution Transformer
---YD10 series
Product brochure
2011/2
Zhejiang Farady Electric Co., Ltd.
ISO9001&ISO14001 certificated enterprise
2. ++++General
Farady Electric is an ISO9001-2008 certified company that has been manufacturing
exceptional distribution and power transformer for last 10 years,one of the reasons for
our sucess over the last decade has been a rigid quality system supported by our
quality assurance programs and ongoing research and development, all design
undergo complete type testing and routine testing, as per the applicable standards
Farady Electric's single phase pad mounted distribution transformers provide a
reliable and affordable solution for clients who need to reduce their overall operating
costs. they are low-profile, compartment-type tranformers,which are generally used
for step-down purposes from an undergroud primary cable supply suitable for
mounting outdoors on pads without additional protective enclosures,and meet the
following standard:
IEC60076,ANSI/IEEEC57.12.00, C57.12.20,C57.12.38, C57.12.90, BS171, SABS
780 etc
++++Application
Our single phase and three phase pad-mounted distribution transformer is
commonly used in
various places including rural areas, remote regions and scattered villages to
provide high quality power supply for daily lighting, agricultural production
and industrial plants. Aside from these, it is also suitable for the energy
saving projects for railway and urban grid.
++++ Feature:
1)Liquid-filled
2)dead front
3))separable,insulated,
high-voltage
connectors,radial or
loop feed
4)standard or customer
specific rating &
configuration
available,with a range
of 10-167kVA
unlta-high efficiency
transformers
extended additional
warranty
Protection
3. ++++Service condition
a) Both indoor or outdoor
b)Air temperature:
Maximum temperature: +40℃; Minimum temperature:-25℃
c) Humidity:
Monthly average humidity 95%; Daily average humidity 90% .
d) Altitude above sea level:
Maximum installation altitude: 2000m.
e) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
f) No frequent violent shake
Note: * Beyond those services condition should enquiry to manufacturer technical dept
during order
++++Tank
l Bolted/welded
domed tank
l tank bottom
raised(does not
touch the pad)
l enclosure hinged
hood
l captive
penta-head hood
locking bolt
l removable sill
l provision for
emergency cable
entrance in sill
l provision for
anchoring the unit
on the pad
l two coated
foundation clamps
supplied with the
unit
l oil fill and drain
plugs provisions
l lifting provision
with recessed
bosses
l provision for
padlock
++++Bushing,terminal
& grounding
l high-voltage and low-voltage
facilities are mounted side by
side
l Externally clamped
high-voltage bushing wells with
parking stands
l low-voltage bushings
l grouding provision,groud strap
from X2 to tank groud
l hood and tank boned by flexible
braided copper
++++Protection
l two-fuse system with
dual-sensing bay-o-net
expulsion fuse and under-oil
partial range backup
current-limiting fuse
l pull-ring type automatic
pressure-relief device
++++Testing
l radio and polarity
l no-load losses and
excitation current
l load losses and
impedance
l applied and
induced voltage
l tank leak-detection
++++others
l laser-engraved
nameplate and
indentification tag
l marking and
warning labels
l units shipped on
pallets secured by
non-metallic straps
Note: *The above parameter is only subject to our standard design, special requirement
can be customized
4. H.V.options L.V.options
H.V fuse with drip
tray
H.V.&dual voltage
switching
++++Electrical characteristics
1. As per IEEE standard C57.12.38-2009(type 2 arrangement units only)
& CSA standard CAN/CSA-C227.3-06(R2011)
2. kVA rating:10-167
3. Primary Voltage:2400-19920
4. HV BIL:60,75,95,125,150KV
5. Secondary Voltage:120-600V
6. ONAN,60HZ
7. Average temperature rise should not exceed 65℃
++++Overall size and weight
5. Table 1: About YD10 Series
Dimension(mm)kVA
W D H
Approx
Weight
(kgs)
10.0 900 840 610 335
15.0 900 840 610 347
25.0 900 840 610 358
37.5 900 840 610 369
50.0 900 840 610 423
75.0 900 940 610 488
100.0 900 990 610 554
167.0 970 1020 760 795
Note: *The above overall size and weight is for reference only, not for construction,
contact Farady technical dept for exact detail
Table 3:single phase pad mounted transformer from 3-333kVA,for rating
voltage below 25kV, low voltage below 1.2kV,refer to 85℃
Nominal
kVA
Io
(% de In)
Po
(W)
Pc
(W)
Pt
(W)
3 2.5 21 70 91
5 2.5 31 91 122
10 2.5 52 142 194
15 2.4 68 192 260
25 2.0 98 289 387
37.5 2.0 130 403 533
50 1.9 160 512 672
75 1.7 214 713 927
100 1.6 263 897 1160
167 1.5 379 1360 1739
Table 4:single phase pad mounted transformer from 15-333kVA,for rating
voltage above 25kV,below 34.5kV,low voltage below 1.2kV,refer to 85℃
Nominal
kVA
Io
(% de In)
Po
(W)
Pc
(W)
Pt
(W)
15 2.4 141 246 387
25 2.4 185 360 545
37.5 2.0 229 488 717
50 2.0 267 606 873
75 1.9 331 821 1152
100 1.7 386 1019 1405
167 1.6 507 1497 2004
250 1.6 628 2025 2653
333 1.6 732 2510 3242
6. Copyright 2014 Farady Electric
Zhejiang Farady Electric Co.,Ltd
TEL:0086-577-61722510/61777258
Fax:0086-577-61777257
Http://www.farady.cn
Email:info@farady.cn
Add:Su’ao,Liushi,Yueqing,Zhejiang,P.R.China, 325604