3. INTRODUCTION
⚫First introduced by Wheaton and Bauman in 1953.
⚫IEC is a technique used to separate ionic compounds
from non-ionic compounds and to separate mixtures
of acids.
3
4. PRINCIPLE
Ionic substances pass quickly through the column.
Non-ionic (molecular) or partially ionized substances are
held up and are eluted more slowly.
Functions by Donnan exclusion mechanism.
Mobile phase- liquid (water or aqueous acid or base)
Stationary phase- ion exchange resins
a) Cationic
b) Anionic
4
5. FEATURES CATIONIC
EXCHANGE RESIN
ANIONIC EXCHANGE
RESIN
Counter ion Positively charged Negatively charged
Fixed ion Negatively charged Positively charged
Examples CMC Diethyl
aminoethyl(DEAE),
Triethyl
aminoethyl(TEAE)
Figure
5
6. Chromatographic system consists of 3 phases.
1. Mobile phase
2. Resin phase
3. Occluded liquid phase
The mobile phase passes through the interstitial volume
existing between the beads of the ion-exchange resin.
The resin phase is the solid resin network and functionalized
groups, which can be considered to be a semipermeable ion-
exchange membrane separating the flowing mobile phase
from the stationary occluded liquid inside the resin.
6
7. An occluded liquid phase is formed by mobile phase that
becomes trapped within the pores of the resin phase.
This trapped liquid acts as the stationary phase of the
system.
When the column is filled with water, pumped through as a
mobile phase, the water molecules accumulate as
hydration spheres around the dissociated functional groups
of the support.
Water contained in the pores of the support and in the
hydration spheres is immobilized, thus forming the
stationary phase.
7
8. The commonly
8
accepted retention mechanism of IEC
involves the formation of a pseudo semi-permeable
membrane around the resin stationary phase.
The ion exclusion process relies on the establishment of an
electrical potential between a dil. MP and a stationary phase
of high ion exchange site concentration.
Ionic solutes of similar charge to the stationary phase
(generally sulfonated cation exchangers are used for weak
acid analytes), experience repulsion from the resin surface,
where as neutral species can penetrate the resins pores and
stationary occluded phase, thus experiencing retention.
10. Thus, analytes are
separated by :
i. Exclusion
10
or
repulsion if they are
ionized and have the
same charge as the
resin.
ii. Adsorption if they
are non-polar or
partially ionized.
11. ADVANTAGES
The eluent is water or aqueous acid or base with little or no
organic modifier, which offers environmental and economic
benefits in addition to compatibility with aqueous sample
matrices.
Difficult separations such as simple aliphatic carboxylic
acids (e.g., formate, acetate, propionate and butyrate) are
possible.
11
12. It is compatible with a wide range of detection methods.
The columns can be ion exchange columns, reversed-phase
or normal-phase columns, or dynamically modified reversed-
phase with an ion pairing agent.
It is stable for long-term analysis of complex samples such as
wine or mustard.
12
14. The typical ion chromatograph consists of an eluent generator
or an eluent reservoir with degassing facilities.
An eluent delivery system including an isocratic or a gradient
high-pressure pump, sample pretreatment and injection
system, which is either a manual valve or an autosampler.
A separation column.
Column packed with stationary phase material.
14
19. A data acquisition system, which is mainly based on personal
computers.
The main feature of typical IC instrumentation is the
suppression system allowing the decrease of background
conductivity of the effluent and providing better sensitivity
for conductimetric detection.
19
20. APPLICATIONS
⚫Technique is mainly used for the separation of weak
acids, particularly carboxylic acids, but has also been
applied to the separation of carbohydrates, phenols
and amino acids and can also be used for the
separation of weak bases.
20
27. REFERENCE
Skoog, Holler, Crouch; Instrumental Analysis.
Bronislaw Krzysztof Glod, Principles and appications
of ion exclusion chromatography, Acta
chromatographica, January 1997.
Haddad;
Encyclopedia
ACIDS/Liquid
Separation
K.L. Ng, P.R.
chromatography;
Science,2000.
27
28. Yal Yashin and A Ya Yashin, HF Walton; Ion exchange/Ion
chromatography instrumentation.
Bronislaw Krzysztof Glod, Marc Baumann; A theoretical
explanation for the retention mechanism of ion exclusion
chromatography; 12 May 2003.
Fotouh R. Mansour Christine L. Kirkpatrick Neil D.
Danielson; Ion Exclusion Chromatography of Aromatic Acids;
Journal of Chromatographic Science, Volume 51, Issue 7,
August 2013, Pages 655–665.
www.chrom-china.com
quimica.udea.edu.co
28
29. www.semanticscholar.org
K. Tanaka, P.R. Haddad, Ion exlcusion chromatography:
liquid chromatography;Encyclopedia of Separation Science,
2000.
B. Paull, P.N. Nesterenko, in Liquid Chromatography:
Fundamentals and Instrumentation, 2013
29