SlideShare ist ein Scribd-Unternehmen logo
1 von 2
Downloaden Sie, um offline zu lesen
• Thermaloc profile ensures an airtight finish
• Thermaloc decreases installation time as it
locks easliy together
• Closed cell so that it will not absorb moisture or
degrade with time
• Made of high density PE foam
• Will not erode with pipe movement
• AS1530.3 compliant foil faced
• Made from recycled material and is recyclable
Youngbo Australia
15/853 Nudgee Road
Northgate QLD 4013
Tel: +61 7 3267 7100
Fax: +61 7 3267 7166
www.youngbo.com.au
CFC FREE
X-Linked
X-Linked
Polyolefin
ThermalocThermaloc
TM
Hot & Cold Pipe Supports
Thermobreak®
Thermoloc is a lightweight and extremely tough closed cell
polyethylene foam pipe support.
•	 Lock together profile decreases installation time and ensures airtight finish
•	 Closed cell will not absorb moisture or degrade over time
•	 Does not erode with pipe movement
•	 AS1530.3 compliant foil faced
HOT & COLD PIPE SUPPORTS
Thermaloc
PHYSICALLYC R O S S L I N K E D
S E K I S U I T E C H N O L O G Y
Product Features
Thermaloc is light weight and extremely tough. Just place the
two pieces over the pipe, squeeze together gently, and apply
AS1530.3 approved foil tape ensuring complete coverage
Compliance with BCA Fire Hazard Properties
Thermaloc complies with the Building Code of Australia (BCA)
specification C1.10 Fire hazard properties for materials used
in Class 2 - 9 buildings.
Quick, Easy & Safe Application
No more cutting. This ensures a flat surface to butt insulation
against, allowing a tight and secure joint. No fibers, no dust,
no mess to clean up afterwards. No special face masks or
gloves required.
Contact Youngbo or your local agent for more information.
Size Availability
Wall Thickness Available
20 mm, 25 mm, 38 mm, 50 mm walls and made to order
wall thickness and ID.
Length Along Pipe
The standard “on pipe” length is 50 mm. 75 mm is
available on request.
Technical Data
Material: 	 Crosslinked Closed Cell PE Foam
Density:	 300 kg /m2
Moisture Absorption	 <1%
(by weight, room temp, 5 hrs)
Tensile Strength	 26.4 kg/m2
Tear Testing 	 8.3 kg/m2
Thermal Conductivity	 0.065 W/mK
(ISO8302-1991)
Constant Working Temperature	 -40 ºC to 105 ºC
Compressive Strength	 3.4 kg/cm2
JIS 6767
©SekisuiPilonPtyLtd.DateofPublication:August2014.
HOT & COLD PIPE SUPPORTS
Softlon and Thermobreak – Registered trademarks of Sekisui Chemical Co. Ltd or its subsidiaries.
SiZE AvAiLABiLiTy
Other sizes available on request.
8-mm 50m X 1200 mm rolls
10-mm 20m X 1200 mm rolls
12-mm 20m X 1200 mm rolls
15-mm 20m X 1200 mm rolls
20-mm 20m X 1200 mm rolls
25~50-mm 2300mm X 1200mm sheets
Product Certification may be plant specific. Please consult with your local representative.
Technical Specifications
Distributed by
Thailand Plant
700/329 Moo 6, Amata Nakorn Industrial Estate,
Tumbol Donhua-Ioh, Amphur Muang Chonburi 20000
Tel: +66 38 213219-26
Email: info@thaisekisui.co.th
Web: www.thaisekisui.co.th
Australian Plant
1-5 Parraweena Rd, PO BOX 2898,
Taren Point NSW 2229 Australia
Tel: +61 2 9525 9880
Email: info@sekisuifoam.com.au
Web: www.sekisuifoam.com.au
PHySiCAL PRoPERTiES
Material: Physically (irradiation) crosslinked closed
cell polyolefin foam with factory applied
reinforced aluminium foil and acrylic
adhesive backing
Density: 25 kg/m3
(foam core only)
Thermal Conductivity: 0.032 W/m/°K (@ 23°C mean temp.)
(ASTM C518) 0.036 W/m/°K (@ 36°C mean temp.)
Water vapour Permeability: 8.19 x 10-15
kg/Pa.s.m
(ASTM E96) (0.029 mg.m/N.h)
Water vapour Permeance: 3.3 x 10-4
g/MN.s
Water absorption by volume: <0.1% v/v
(JIS K6767) (0.00038 g/cm2
)
Permeability Resistance Factor: μ > 20,000
Resistance to fungi: Zero Growth
(ASTM G21)
ozone Resistance: Excellent
Uv Resistance: Excellent
Noise Reduction Coefficient: 0.20 (12mm foam thickness)
(ISO 354) 0.30 (25mm foam thickness)
operating Temperature Range: -80 °C ~ +100 °C (no adhesive)
GreenStar Rating: Low VOC Emitting
(ASTM D5116)
Physical Property Requirements: COMPLIES (Type II - Sheet)
(ASTM C1427)
REACH Directives: COMPLIES
(1907/2006/EC)
FiRE AND SMoKE BEHAvioUR
BS476 Parts 6 & 7: CLASS 0
AS1530 Part 3 Ignitability Index: 0
Spread of Flame Index: 0
Heat Evolved Index: 0
Smoke Developed Index: 0-1
ASTM E84: COMPLIES (NFPA 90A & B)
Flame Spread Index: <25
Smoke Developed Index: <50
ASTM C411: COMPLIES (NFPA 90A & B)
FM 4924 Thermobreak Sheet APPROVED
Up to 25mm thickness
AS 3837 BCA Group Number: 1
Smoke Index: ≤250
BS 6853 Annex B Smoke Toxicity COMPLIES (R < 1.0)
iMo MSC 61(67) Part 2 Smoke Toxicity COMPLIES
iSo 5659 Part 2 Smoke Density COMPLIES (IMO MSC 61(67) Part 2)
Dm < 200
Satisfies max allowable
concentrations for the
following combustion gases:
CO, HCl, HBr, HF, HCN, NOx, SO2
UL 94 Horizontal Burn APPROVED (HF-1)
Benefits
Built in Loc
Once tightly taped, Thermaloc will prevent any air movement
through the join. This is especially important in cold line
applications to prevent potential air condensation
Tough & Durable
Thermaloc pipe supports are made of high density,
crosslinked, closed cell polyethylene foam. As they are closed
cell they absorb negligible moisture, and retain their insulation
properties throughout the life of the installation.
Non Erosion with Pipe Movement
Pipes move with contraction and expansion, eroding the
ferrule. The tough PE foam will resist movement and prevent
gap formation over time.
Health & Safety
As the blocks are preformed there is no need for cutting,
so there is no dust and no mess. They do not emit fibrous
particles during installation or over time.
Performance Life
Thermaloc is closed cell and unaffected by water and
humidity. This ensures continual performance over the life of
the installation.
Chemical Resistance
Thermaloc is resistant to detergents, diluted acids, alkalis,
alcohols, esters and fungi ensuring performance in even the
most demanding applications.
Sekisui Foam Australia
Head Office
1-5 Parraweena Rd, PO Box 2898,
Taren Point NSW 2229 Australia
Tel:	 +61 2 9525 9880
Fax:	 +61 2 9525 8004
Email:	info@sekisuifoam.com.au
Web:	www.sekisuifoam.com.au
Queensland Branch
15/853 Nudgee Rd, PO Box 448,
Northgate QLD 4013 Australia
Tel: 	 +61 7 3267 7100
Fax: 	 +61 7 3267 7166
Email: 	info@sekisuifoam.com.au
Web: 	 www.sekisuifoam.com.au
Thermaloc

Weitere ähnliche Inhalte

Was ist angesagt?

Sealco Portfolio 2016 Web
Sealco Portfolio 2016 WebSealco Portfolio 2016 Web
Sealco Portfolio 2016 Web
Jeff Fitness
 
WPM 002 Australian version
WPM 002 Australian versionWPM 002 Australian version
WPM 002 Australian version
nandu_raga
 
(Pds) nitoproof rs_(green_label)
(Pds) nitoproof rs_(green_label)(Pds) nitoproof rs_(green_label)
(Pds) nitoproof rs_(green_label)
HendraWahyu6
 
Terrace Water Proofing
Terrace Water ProofingTerrace Water Proofing
Terrace Water Proofing
D K Associates
 
Bsk global kay-tex customer presentation
Bsk global kay-tex customer presentationBsk global kay-tex customer presentation
Bsk global kay-tex customer presentation
Ertunc Ekin
 

Was ist angesagt? (20)

DONIT Tesnit Guide to AsbestosFree
DONIT Tesnit Guide to AsbestosFreeDONIT Tesnit Guide to AsbestosFree
DONIT Tesnit Guide to AsbestosFree
 
Sealco Portfolio 2016 Web
Sealco Portfolio 2016 WebSealco Portfolio 2016 Web
Sealco Portfolio 2016 Web
 
Barrier Bac Primer for Design Pros
Barrier Bac Primer for Design ProsBarrier Bac Primer for Design Pros
Barrier Bac Primer for Design Pros
 
WPM 002 Australian version
WPM 002 Australian versionWPM 002 Australian version
WPM 002 Australian version
 
Rubber
RubberRubber
Rubber
 
Easy Seal Neu
Easy Seal NeuEasy Seal Neu
Easy Seal Neu
 
FDA O-Rings
FDA O-RingsFDA O-Rings
FDA O-Rings
 
Encap systems7192010
Encap systems7192010Encap systems7192010
Encap systems7192010
 
(Pds) nitoproof rs_(green_label)
(Pds) nitoproof rs_(green_label)(Pds) nitoproof rs_(green_label)
(Pds) nitoproof rs_(green_label)
 
Neogard Product Presentation N6
Neogard Product Presentation   N6Neogard Product Presentation   N6
Neogard Product Presentation N6
 
Terrace Water Proofing
Terrace Water ProofingTerrace Water Proofing
Terrace Water Proofing
 
Types of gasket materials
Types of gasket materialsTypes of gasket materials
Types of gasket materials
 
High Voltage Silicone Rubber Overhead Line Covers for Bare Conductor
High Voltage Silicone Rubber Overhead Line Covers for Bare ConductorHigh Voltage Silicone Rubber Overhead Line Covers for Bare Conductor
High Voltage Silicone Rubber Overhead Line Covers for Bare Conductor
 
Filter Fabric Nomex (Aramid) Felt From Zukun Filtration
Filter Fabric Nomex (Aramid) Felt From Zukun FiltrationFilter Fabric Nomex (Aramid) Felt From Zukun Filtration
Filter Fabric Nomex (Aramid) Felt From Zukun Filtration
 
Bsk global kay-tex customer presentation
Bsk global kay-tex customer presentationBsk global kay-tex customer presentation
Bsk global kay-tex customer presentation
 
Issue 05
Issue 05Issue 05
Issue 05
 
Non metallic cladding
Non metallic claddingNon metallic cladding
Non metallic cladding
 
Sustainable Solutions for Thermal, Fire & Sound Control – Roxul
Sustainable Solutions for Thermal, Fire & Sound Control – RoxulSustainable Solutions for Thermal, Fire & Sound Control – Roxul
Sustainable Solutions for Thermal, Fire & Sound Control – Roxul
 
Osmosis - The Bane of Liquid Applied Waterproofing Membranes
Osmosis - The Bane of Liquid Applied Waterproofing MembranesOsmosis - The Bane of Liquid Applied Waterproofing Membranes
Osmosis - The Bane of Liquid Applied Waterproofing Membranes
 
N1 never seez brochure 2011
N1 never seez brochure 2011N1 never seez brochure 2011
N1 never seez brochure 2011
 

Andere mochten auch

RJBINFO de tudo um pouco
RJBINFO de tudo um poucoRJBINFO de tudo um pouco
RJBINFO de tudo um pouco
VisualBee.com
 
Acs event calendar january 2013
Acs event calendar january 2013Acs event calendar january 2013
Acs event calendar january 2013
SCARROLL16
 
Letter - Homes On TV
Letter - Homes On TVLetter - Homes On TV
Letter - Homes On TV
Robert Eckert
 
CERTIFICATE FOR REVIT ARCHITECTURE 2014 COMPLETION
CERTIFICATE FOR REVIT ARCHITECTURE 2014 COMPLETIONCERTIFICATE FOR REVIT ARCHITECTURE 2014 COMPLETION
CERTIFICATE FOR REVIT ARCHITECTURE 2014 COMPLETION
Carlos Zapanta
 

Andere mochten auch (13)

שירביט חברה לביטוח לקוחות ממליצים מאי 2014
שירביט חברה לביטוח לקוחות ממליצים מאי 2014שירביט חברה לביטוח לקוחות ממליצים מאי 2014
שירביט חברה לביטוח לקוחות ממליצים מאי 2014
 
RJBINFO de tudo um pouco
RJBINFO de tudo um poucoRJBINFO de tudo um pouco
RJBINFO de tudo um pouco
 
Acs event calendar january 2013
Acs event calendar january 2013Acs event calendar january 2013
Acs event calendar january 2013
 
Capa
CapaCapa
Capa
 
Volantino Brico Casa Agosto 2014
 Volantino Brico Casa Agosto 2014 Volantino Brico Casa Agosto 2014
Volantino Brico Casa Agosto 2014
 
ASAFUKU(麻福)の特徴
ASAFUKU(麻福)の特徴ASAFUKU(麻福)の特徴
ASAFUKU(麻福)の特徴
 
Documento índice a
Documento índice aDocumento índice a
Documento índice a
 
Arvinoor siregar sh menegaskan salah satu fungsi copy (18)
Arvinoor siregar sh menegaskan salah satu fungsi   copy (18)Arvinoor siregar sh menegaskan salah satu fungsi   copy (18)
Arvinoor siregar sh menegaskan salah satu fungsi copy (18)
 
Alfabetização sem traumas
Alfabetização sem traumasAlfabetização sem traumas
Alfabetização sem traumas
 
Students want parties to return to talks
Students want parties to return to talksStudents want parties to return to talks
Students want parties to return to talks
 
Rotor.mueblesderecepciongk is-170
Rotor.mueblesderecepciongk is-170Rotor.mueblesderecepciongk is-170
Rotor.mueblesderecepciongk is-170
 
Letter - Homes On TV
Letter - Homes On TVLetter - Homes On TV
Letter - Homes On TV
 
CERTIFICATE FOR REVIT ARCHITECTURE 2014 COMPLETION
CERTIFICATE FOR REVIT ARCHITECTURE 2014 COMPLETIONCERTIFICATE FOR REVIT ARCHITECTURE 2014 COMPLETION
CERTIFICATE FOR REVIT ARCHITECTURE 2014 COMPLETION
 

Ähnlich wie Thermobreak Thermaloc - Brochure 270814 D

Thermobreak Thermacoil - Brochure 270814 D
Thermobreak Thermacoil - Brochure 270814 DThermobreak Thermacoil - Brochure 270814 D
Thermobreak Thermacoil - Brochure 270814 D
Gary Haydon
 
Thermobreak Solar - Brochure 230914 D
Thermobreak Solar - Brochure 230914 DThermobreak Solar - Brochure 230914 D
Thermobreak Solar - Brochure 230914 D
Gary Haydon
 
Thermobreak Tube - Brochure 230914 D
Thermobreak Tube - Brochure 230914 DThermobreak Tube - Brochure 230914 D
Thermobreak Tube - Brochure 230914 D
Gary Haydon
 
8443-6.5 3M Silicone Rubber Cold Shrink Insulators
8443-6.5 3M Silicone Rubber Cold Shrink Insulators 8443-6.5 3M Silicone Rubber Cold Shrink Insulators
8443-6.5 3M Silicone Rubber Cold Shrink Insulators
Thorne & Derrick International
 
8443-2 3M Silicone Rubber Cold Shrink Insulators
8443-2 3M Silicone Rubber Cold Shrink Insulators 8443-2 3M Silicone Rubber Cold Shrink Insulators
8443-2 3M Silicone Rubber Cold Shrink Insulators
Thorne & Derrick International
 
8447-3.2 3M Silicone Rubber Cold Shrink Insulators
8447-3.2 3M Silicone Rubber Cold Shrink Insulators8447-3.2 3M Silicone Rubber Cold Shrink Insulators
8447-3.2 3M Silicone Rubber Cold Shrink Insulators
Thorne & Derrick International
 
8445-2.5 3M Silicone Rubber Cold Shrink Insulators
8445-2.5 3M Silicone Rubber Cold Shrink Insulators8445-2.5 3M Silicone Rubber Cold Shrink Insulators
8445-2.5 3M Silicone Rubber Cold Shrink Insulators
Thorne & Derrick International
 
8447-8 3M Silicone Rubber Cold Shrink Insulators
8447-8 3M Silicone Rubber Cold Shrink Insulators8447-8 3M Silicone Rubber Cold Shrink Insulators
8447-8 3M Silicone Rubber Cold Shrink Insulators
Thorne & Derrick International
 

Ähnlich wie Thermobreak Thermaloc - Brochure 270814 D (20)

Thermobreak Thermacoil - Brochure 270814 D
Thermobreak Thermacoil - Brochure 270814 DThermobreak Thermacoil - Brochure 270814 D
Thermobreak Thermacoil - Brochure 270814 D
 
Thermobreak Solar - Brochure 230914 D
Thermobreak Solar - Brochure 230914 DThermobreak Solar - Brochure 230914 D
Thermobreak Solar - Brochure 230914 D
 
Centroid adhesives, sealants, butyl tapes, silicone
Centroid adhesives, sealants, butyl tapes, silicone Centroid adhesives, sealants, butyl tapes, silicone
Centroid adhesives, sealants, butyl tapes, silicone
 
Butyl mastic tapes and sealants for automotive vaccum bagging cable jointing
Butyl mastic tapes and sealants for automotive vaccum bagging cable jointingButyl mastic tapes and sealants for automotive vaccum bagging cable jointing
Butyl mastic tapes and sealants for automotive vaccum bagging cable jointing
 
Protection of piles
Protection of pilesProtection of piles
Protection of piles
 
Waterguard pu membrane
Waterguard pu membraneWaterguard pu membrane
Waterguard pu membrane
 
Multifoam
MultifoamMultifoam
Multifoam
 
Thermobreak Tube - Brochure 230914 D
Thermobreak Tube - Brochure 230914 DThermobreak Tube - Brochure 230914 D
Thermobreak Tube - Brochure 230914 D
 
FiloSeal+ Telstra Approved Duct Sealing System
FiloSeal+ Telstra Approved Duct Sealing SystemFiloSeal+ Telstra Approved Duct Sealing System
FiloSeal+ Telstra Approved Duct Sealing System
 
What is PFA Tubing?
What is PFA Tubing?What is PFA Tubing?
What is PFA Tubing?
 
Reinforced EPDM Membranes
Reinforced EPDM MembranesReinforced EPDM Membranes
Reinforced EPDM Membranes
 
8443-6.5 3M Silicone Rubber Cold Shrink Insulators
8443-6.5 3M Silicone Rubber Cold Shrink Insulators 8443-6.5 3M Silicone Rubber Cold Shrink Insulators
8443-6.5 3M Silicone Rubber Cold Shrink Insulators
 
8445-7.5 3M Silicone Rubber Cold Shrink Insulators
8445-7.5 3M Silicone Rubber Cold Shrink Insulators8445-7.5 3M Silicone Rubber Cold Shrink Insulators
8445-7.5 3M Silicone Rubber Cold Shrink Insulators
 
8443-2 3M Silicone Rubber Cold Shrink Insulators
8443-2 3M Silicone Rubber Cold Shrink Insulators 8443-2 3M Silicone Rubber Cold Shrink Insulators
8443-2 3M Silicone Rubber Cold Shrink Insulators
 
8447-3.2 3M Silicone Rubber Cold Shrink Insulators
8447-3.2 3M Silicone Rubber Cold Shrink Insulators8447-3.2 3M Silicone Rubber Cold Shrink Insulators
8447-3.2 3M Silicone Rubber Cold Shrink Insulators
 
8445-2.5 3M Silicone Rubber Cold Shrink Insulators
8445-2.5 3M Silicone Rubber Cold Shrink Insulators8445-2.5 3M Silicone Rubber Cold Shrink Insulators
8445-2.5 3M Silicone Rubber Cold Shrink Insulators
 
8447-8 3M Silicone Rubber Cold Shrink Insulators
8447-8 3M Silicone Rubber Cold Shrink Insulators8447-8 3M Silicone Rubber Cold Shrink Insulators
8447-8 3M Silicone Rubber Cold Shrink Insulators
 
No.51 e
No.51 eNo.51 e
No.51 e
 
Water proofing
Water proofingWater proofing
Water proofing
 
FiloSeal+HD datasheet
FiloSeal+HD datasheetFiloSeal+HD datasheet
FiloSeal+HD datasheet
 

Thermobreak Thermaloc - Brochure 270814 D

  • 1. • Thermaloc profile ensures an airtight finish • Thermaloc decreases installation time as it locks easliy together • Closed cell so that it will not absorb moisture or degrade with time • Made of high density PE foam • Will not erode with pipe movement • AS1530.3 compliant foil faced • Made from recycled material and is recyclable Youngbo Australia 15/853 Nudgee Road Northgate QLD 4013 Tel: +61 7 3267 7100 Fax: +61 7 3267 7166 www.youngbo.com.au CFC FREE X-Linked X-Linked Polyolefin ThermalocThermaloc TM Hot & Cold Pipe Supports Thermobreak® Thermoloc is a lightweight and extremely tough closed cell polyethylene foam pipe support. • Lock together profile decreases installation time and ensures airtight finish • Closed cell will not absorb moisture or degrade over time • Does not erode with pipe movement • AS1530.3 compliant foil faced HOT & COLD PIPE SUPPORTS Thermaloc PHYSICALLYC R O S S L I N K E D S E K I S U I T E C H N O L O G Y
  • 2. Product Features Thermaloc is light weight and extremely tough. Just place the two pieces over the pipe, squeeze together gently, and apply AS1530.3 approved foil tape ensuring complete coverage Compliance with BCA Fire Hazard Properties Thermaloc complies with the Building Code of Australia (BCA) specification C1.10 Fire hazard properties for materials used in Class 2 - 9 buildings. Quick, Easy & Safe Application No more cutting. This ensures a flat surface to butt insulation against, allowing a tight and secure joint. No fibers, no dust, no mess to clean up afterwards. No special face masks or gloves required. Contact Youngbo or your local agent for more information. Size Availability Wall Thickness Available 20 mm, 25 mm, 38 mm, 50 mm walls and made to order wall thickness and ID. Length Along Pipe The standard “on pipe” length is 50 mm. 75 mm is available on request. Technical Data Material: Crosslinked Closed Cell PE Foam Density: 300 kg /m2 Moisture Absorption <1% (by weight, room temp, 5 hrs) Tensile Strength 26.4 kg/m2 Tear Testing 8.3 kg/m2 Thermal Conductivity 0.065 W/mK (ISO8302-1991) Constant Working Temperature -40 ºC to 105 ºC Compressive Strength 3.4 kg/cm2 JIS 6767 ©SekisuiPilonPtyLtd.DateofPublication:August2014. HOT & COLD PIPE SUPPORTS Softlon and Thermobreak – Registered trademarks of Sekisui Chemical Co. Ltd or its subsidiaries. SiZE AvAiLABiLiTy Other sizes available on request. 8-mm 50m X 1200 mm rolls 10-mm 20m X 1200 mm rolls 12-mm 20m X 1200 mm rolls 15-mm 20m X 1200 mm rolls 20-mm 20m X 1200 mm rolls 25~50-mm 2300mm X 1200mm sheets Product Certification may be plant specific. Please consult with your local representative. Technical Specifications Distributed by Thailand Plant 700/329 Moo 6, Amata Nakorn Industrial Estate, Tumbol Donhua-Ioh, Amphur Muang Chonburi 20000 Tel: +66 38 213219-26 Email: info@thaisekisui.co.th Web: www.thaisekisui.co.th Australian Plant 1-5 Parraweena Rd, PO BOX 2898, Taren Point NSW 2229 Australia Tel: +61 2 9525 9880 Email: info@sekisuifoam.com.au Web: www.sekisuifoam.com.au PHySiCAL PRoPERTiES Material: Physically (irradiation) crosslinked closed cell polyolefin foam with factory applied reinforced aluminium foil and acrylic adhesive backing Density: 25 kg/m3 (foam core only) Thermal Conductivity: 0.032 W/m/°K (@ 23°C mean temp.) (ASTM C518) 0.036 W/m/°K (@ 36°C mean temp.) Water vapour Permeability: 8.19 x 10-15 kg/Pa.s.m (ASTM E96) (0.029 mg.m/N.h) Water vapour Permeance: 3.3 x 10-4 g/MN.s Water absorption by volume: <0.1% v/v (JIS K6767) (0.00038 g/cm2 ) Permeability Resistance Factor: μ > 20,000 Resistance to fungi: Zero Growth (ASTM G21) ozone Resistance: Excellent Uv Resistance: Excellent Noise Reduction Coefficient: 0.20 (12mm foam thickness) (ISO 354) 0.30 (25mm foam thickness) operating Temperature Range: -80 °C ~ +100 °C (no adhesive) GreenStar Rating: Low VOC Emitting (ASTM D5116) Physical Property Requirements: COMPLIES (Type II - Sheet) (ASTM C1427) REACH Directives: COMPLIES (1907/2006/EC) FiRE AND SMoKE BEHAvioUR BS476 Parts 6 & 7: CLASS 0 AS1530 Part 3 Ignitability Index: 0 Spread of Flame Index: 0 Heat Evolved Index: 0 Smoke Developed Index: 0-1 ASTM E84: COMPLIES (NFPA 90A & B) Flame Spread Index: <25 Smoke Developed Index: <50 ASTM C411: COMPLIES (NFPA 90A & B) FM 4924 Thermobreak Sheet APPROVED Up to 25mm thickness AS 3837 BCA Group Number: 1 Smoke Index: ≤250 BS 6853 Annex B Smoke Toxicity COMPLIES (R < 1.0) iMo MSC 61(67) Part 2 Smoke Toxicity COMPLIES iSo 5659 Part 2 Smoke Density COMPLIES (IMO MSC 61(67) Part 2) Dm < 200 Satisfies max allowable concentrations for the following combustion gases: CO, HCl, HBr, HF, HCN, NOx, SO2 UL 94 Horizontal Burn APPROVED (HF-1) Benefits Built in Loc Once tightly taped, Thermaloc will prevent any air movement through the join. This is especially important in cold line applications to prevent potential air condensation Tough & Durable Thermaloc pipe supports are made of high density, crosslinked, closed cell polyethylene foam. As they are closed cell they absorb negligible moisture, and retain their insulation properties throughout the life of the installation. Non Erosion with Pipe Movement Pipes move with contraction and expansion, eroding the ferrule. The tough PE foam will resist movement and prevent gap formation over time. Health & Safety As the blocks are preformed there is no need for cutting, so there is no dust and no mess. They do not emit fibrous particles during installation or over time. Performance Life Thermaloc is closed cell and unaffected by water and humidity. This ensures continual performance over the life of the installation. Chemical Resistance Thermaloc is resistant to detergents, diluted acids, alkalis, alcohols, esters and fungi ensuring performance in even the most demanding applications. Sekisui Foam Australia Head Office 1-5 Parraweena Rd, PO Box 2898, Taren Point NSW 2229 Australia Tel: +61 2 9525 9880 Fax: +61 2 9525 8004 Email: info@sekisuifoam.com.au Web: www.sekisuifoam.com.au Queensland Branch 15/853 Nudgee Rd, PO Box 448, Northgate QLD 4013 Australia Tel: +61 7 3267 7100 Fax: +61 7 3267 7166 Email: info@sekisuifoam.com.au Web: www.sekisuifoam.com.au Thermaloc