Versico LiveRoof® System
                                                        Table of Contents
                                                                     January 2008

                                                                                                                                                   Page
Part I - General
    1.01     Description .............................................................................................................................3
    1.02     Extensive (Shallow) Green Roof Definition ..........................................................................3
    1.03     Design Guidelines ..................................................................................................................3
    1.04     Quality Assurance ..................................................................................................................4
    1.05     Submittals...............................................................................................................................4
    1.06     Warranty.................................................................................................................................5
    1.07     Job Conditions........................................................................................................................5

Part II - Products
    2.01     General ...................................................................................................................................5
    2.02     Versico LiveRoof Module Specifications ..............................................................................5
    2.03     Related Versico Materials ......................................................................................................6
    2.04     Growth Media Properties .......................................................................................................6
    2.05     Plants ......................................................................................................................................7
    2.06     Edge Elements........................................................................................................................7
    2.07     “Hardscape” Items (Optional) ................................................................................................7

Part III - Execution
    3.01     General ...................................................................................................................................7
    3.02     Installation of 40-Mil Geomembrane Slip Sheet....................................................................8
    3.03     Application of LiveRoof Modules .........................................................................................8
    3.04     Maintenance ...........................................................................................................................9


Details




603336 – Versico LiveRoof System - 1/2008
Versico LiveRoof® System
                                                   January 2008


PART 1            GENERAL

1.01     DESCRIPTION

The Versico LiveRoof® System incorporates pre-planted, pre-grown “module trays” in lieu of traditional
components used above an adhered roofing membrane (i.e., drainage boards, root barriers, moisture mats, and
growth media). The roofing membrane may consist of VersiGard® (black) non-reinforced or reinforced EPDM
membrane or VersiWeld® TPO membrane. The type of membrane is dependent upon the length of warranty
selected. Refer to Paragraph 1.03, Design Guidelines, for specific requirements.

The “module trays” are lightweight, composed of recycled plastics (100% post industrial recycled polypropylene),
with walls 100-mils thick, and arrive at the building site ready for installation. Standard tray size is 1' x 2' x 3-
1/4" with 4-1/4" soil depth.

For information about the LiveRoof modules, weights, planting types, and growth media, refer to Part 2, Products.

1.02     EXTENSIVE (SHALLOW) GREEN ROOF DEFINITION

A shallow planting system (using 3-1/4" tall LiveRoof tray modules) pre-planted and pre-grown to a height of
approximately 4-1/4" using an engineered blend of inorganic and organic components. The growing media types
are chosen for the specific climate zone and the anticipated weight above the membrane assembly is
approximately 27-29 pounds per square foot.

1.03     DESIGN GUIDELINES

A.       For 10 or 15-year warranties, the assembly requires the use of 60-mil EPDM or 60-mil TPO installed in
         an adhered fashion.

B.       For 20-year warranties, the assembly requires the use of 75-mil VersiGard Reinforced EPDM or 72-mil
         VersiWeld TPO installed in an adhered fashion.

C.       An EPDM or TPO membrane shall be fully adhered, typically to polyisocyanurate insulation, with layers
         of insulation set in adhesive. As an option, bottom layers of insulation can be mechanically fastened to
         the roof deck with the top layer set in adhesive.

D.       Refer to Versico’s specifications for specific requirements concerning membrane adhesion and splicing
         criteria, insulation type and securement methods, product delivery, storage and handling guidelines, and
         applicable installation of all materials and details.

E.       To facilitate drainage, a minimum roof slope of 1/4" in 12" must be provided at the waterproofing
         membrane level.
603336 – Versico LiveRoof System - 1/2008                                                                          3
F.       The Versico LiveRoof System shall not be installed on projects over 50' in height. Projects in excess of
         50' must be forwarded to Versico for review prior to bid and installation.

G.       Proper decking shall be provided by the building owner. The building owner or its designated
         representative must ensure the building structure is investigated by a registered engineer to ensure its
         ability to withstand the total weight of the specified roofing system, as well as construction loads and live
         loads, in accordance with all applicable codes. The specifier must also designate the maximum allowable
         weight and location for material loading and storage on the roof.

H.       The installation season for the LiveRoof system will vary based upon the local climate. LiveRoof
         modules may be installed when all of the following conditions are met:

         1.       The roof is frost- and ice-free
         2.       The plant material has been properly cold- or heat/sun- acclimatized at the LiveRoof nursery
         3.       The soil within the modules is unfrozen
         4.       The LiveRoof modules are vegetated with 95% coverage or greater.

I.       Prior to installing the LiveRoof modules, a black 40-mil GeoMembrane slip sheet shall be installed over
         the roofing membrane at all areas where the modules will be placed. When VersiWeld TPO membrane is
         used, Geomembrane sheets shall be field welded a minimum of 1-1/2" in width using a Heat Welder. As
         an option for VersiGard EPDM membranes, QA Seam Tape/V-150 or LV-600 Primer can be used to
         splice adjoining slip sheets.

J.       When trays are to be installed in high wind areas, Versico should be contacted regarding appropriate
         methods to prevent tray movement and/or soil media wind erosion.

1.04     QUALITY ASSURANCE

A.       A pre-installation meeting should be coordinated by the specifier and attended by the LiveRoof installer,
         the roofing applicator, membrane manufacturer’s representative and other trades working on the roof
         system both before and after membrane installation. The purpose of this meeting is to discuss the
         necessity of ensuring proper membrane protection during all phases of installation and to review other
         applicable requirements or unusual field conditions.

B.       Upon request by the Authorized Applicator, an inspection will be conducted by a Field Service
         Representative of Versico to ascertain that the membrane roofing system has been installed according to
         Versico's specifications and details. This inspection shall be coordinated prior to installing the
         LiveRoof components (40-mil GeoMembrane slip sheet and the LiveRoof modules) so access to the
         membrane is not impaired.

         Note:      The roofing applicator must notify Versico at least 3 weeks in advance of applicable inspection
                    dates for coordination purposes.

C.       A final inspection will be conducted after application of the LiveRoof modules to ensure proper
         installation.

D.       Flood testing, electronic testing, or other leak detection means are strongly advised to check the
         waterproof integrity of the membrane prior to installing the LiveRoof components (black 40-mil
         GeoMembrane slip sheet and the LiveRoof modules).

1.05     SUBMITTALS

A.       To ensure compliance with Versico's warranty requirements, all projects should be forwarded to
         Versico for review prior to installation.


603336 – Versico LiveRoof System - 1/2008                                                                           4
B.       A dimensioned layout of LiveRoof modules and all field splices shall be included along with the
         project submittals (shop drawing and Request for Warranty).

C.       For all projects, prior to project inspection by Versico, a final shop drawing must be approved by Versico.

1.06     WARRANTY

A.       A 10, 15 or 20-year System Warranty is available for a charge on commercial buildings and applies only
         to products manufactured or marketed by Versico Incorporated. The membrane system is defined as
         membrane, flashings, adhesives, sealants, and other Versico brand products utilized in this installation.
         For a complete description of these products, refer to the “Products Section” or the applicable
         “Attachment” in the Versico specifications.

B.       The formation or presence of mold or fungi in a building is dependent upon a broad range of factors
         including, but not limited to, the presence of spores and nutrient sources, moisture, temperatures, climatic
         conditions, relative humidity, and heating/ventilating systems and their maintenance and operating
         capabilities. These factors are beyond the control of Versico and Versico shall not be responsible for any
         claims, repairs, restoration or damages relating to the presence of any irritants, contaminants, vapors,
         fumes, molds, fungi, bacteria, spores, mycotoxins, or the like in any building or in the air, land, or water
         serving the building.

1.07     JOB CONDITIONS

A.       Coordination between various trades is essential to avoid unnecessary rooftop traffic over sections of the
         roof and to prevent damage to the membrane. Heavily traveled areas must be protected by placing
         temporary protection courses to prevent damage to the membrane.

B.       The use of a vapor retarder to protect insulation and reduce moisture accumulation within an insulated
         roofing assembly should be investigated by the specifier. Consult the latest publications by ASHRAE
         (American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.) and NRCA (National
         Roofing Contractors Association) for specific information.


PART 2            PRODUCTS

2.01     GENERAL

The components of this roofing system are to be products of Versico. The installation, performance, or integrity
of products by others is not the responsibility of Versico and is expressly disclaimed by the Versico Warranty.

2.02     VERSICO LiveRoof® MODULE SPECIFICATIONS

LiveRoof modules are black in color and formed with 100-mil thick (sidewall) polypropylene. Modules are pre-
planted with growth media and plant species of the color and type desired by the building owner. LiveRoof
modules are pre-grown to maturity (95%+ soil coverage). Each tray also contains a Soil Elevator™, an insert
collar that allows soil to be packaged above the edge of the module. The Soil Elevator is removed after the
modules are installed to promote a continuous media appearance. Physical properties are as follows:




603336 – Versico LiveRoof System - 1/2008                                                                          5
Element                                                    Description
 Depth of Standard Modules                             3-1/4"
 Soil Depth                                            Approx. 4-1/4"
 Module Size                                           1' x 2'
 Weight of Planted Modules (fully saturated weights)   27 – 29 lb. per sq. ft., fully saturated
 Module Material                                       100% post industrial recycled polypropylene
 Module Clearance above Roofing Surface                0.5"
 Color of Modules                                      Black
 Growth Media                                          Engineered blend consisting of organic and inorganic components.
 Required underlayment for modules                     Black, 40-mil GeoMembrane slip sheet
                                                       Typically not required for LiveRoof Standard Modules, but
                                                       recommended for backup during prolonged, hot, dry, windy
 Irrigation System                                     weather patterns; an overhead irrigation type system is
                                                       recommended, when specified. An overhead system designed by
                                                       Spring Brook Supply is recommended.
 Plants                                                See individual grower recommendations for regional selections
                                                       Wood, recycled composite wood, aluminum, pavers or other
 Edge Treatment                                        specialty materials. Co-engineered Permaloc® non-fastened,
                                                       aluminum, L-shaped edging is recommended.

2.03      RELATED VERSICO MATERIALS

A.        For use with VersiGard EPDM membrane – G200SA Yellow Substrate Adhesive, VersiGard QA Seam
          Tape, Primer, Lap Sealant, Cured EPDM Flashing, Pressure-Sensitive Flashing, T-Joint Covers, Uncured
          Flashing, Fasteners/Plates, Water Cut-Off Mastic, Pourable Sealer, Pre-Molded Pipe Seals, Pressure-
          Sensitive Inside/Outside Corner, Pourable Sealer Pockets, and Termination Bars.

B.        For use with VersiWeld TPO membrane – VersiWeld Bonding Adhesive, Cut-Edge Sealant, reinforced
          and non-reinforced flashing, Water Cut-Off Mastic, PT 304 Sealant, Molded Pocket Sealant, Weathered
          Membrane Cleaner, Pre-Molded Pipe Seals, Split Pipe Boots, Curb Wrap Corners, and Termination Bars.

C.        40-mil GeoMembrane Slip Sheet (black) – a heat-weldable, non-reinforced, polypropylene sheet
          designed for liners in potable water and industrial containment applications. The membrane is
          specifically formulated for long-term use in buried or exposed geomembrane applications. Available in
          rolls 12' wide by 100' long.

D.        Other Versico products, such as insulation and edgings/copings, are also required when such
          components are to be included as part of the System Warranty.

2.04      GROWTH MEDIA PROPERTIES

The Growth Media mix provides stable soil structure, high porosity, and high moisture holding properties. The
growth media also provides excellent drainage while remaining lightweight. LiveRoof® media is an engineered
blend of inorganic and organic components based upon the fine side of German FLL guidelines modified so as to
contain ecologically sustainable levels of organic content. LiveRoof® specified engineered soil is 93+% (by dry
weight) inorganic content for minimal shrinkage/decomposition.




603336 – Versico LiveRoof System - 1/2008                                                                             6
2.05     PLANTS

LiveRoof recommended design mix of highly drought resistant ground covers that can thrive in an
extensive/shallow environment based on the project location. Local horticulturists should be consulted for
specific recommendations.

A.       Planting density: 95% coverage at the time of shipment.

B.       Special Order: Specific plantings that meet the climate zone and the desired look the roof garden is to
         achieve. Special patterns may be accomplished with various plant species to give a pattern look for color,
         plant height, etc. This is accomplished by coordinating a specific design with the owner/architect and
         LiveRoof grower.

2.06     EDGE ELEMENTS

Consisting of aluminum with perforations for drainage for placement at exposed edges of the modules. Edging is
4.5" x 3", with a minimum gauge of 210-mil. LiveRoof recommends co-engineered Permaloc® non-fastened,
perforated aluminum, L-shaped edging.

A.       Edging is required for use between modules and stone ballast.

B.       Edging is preferred, but not required, for use between modules and concrete, recycled glass, or rubber
         pavers.

C.       If walkway pads are used in place of pavers, use 10 x 16 x 1" wafer head self-tapping screws to affix
         edging to the modules to prevent slippage.

2.07     “HARDSCAPE” ITEMS (optional)

A.       Individual concrete plaza pavers – 2' x 2' x 2" thick precast concrete pavers weighing a minimum of 18
         psf with a minimum compressive strength of 6500 psi.

B.       Paver Pedestals – Rubber paver pedestals to elevate the surface of the pavers above the roof membrane
         and promote positive drainage and protection from freeze/thaw.

C.       Versico Rubber Paver – A 2' x 2' x 2" thick rubber paver weighing approximately 24 pounds per unit (6
         pounds per square foot) manufactured from recycled rubber, which provides a resilient, shock absorbing,
         weather resistant surface. Available in colors of terre cotta (red) and black. Optional sizes and colors are
         also available.

D.       Stone Ballast – Nominal 1-1/2" diameter rounded water worn gravel which conforms with ASTM D448,
         gradation size #4, applied at a minimum of 10 pounds per square foot. Used around roof drains and
         along walls as a transition from the modules and to promote drainage.


PART 3            EXECUTION

3.01     GENERAL

A.       Refer to Versico’s specifications for specific requirements concerning membrane adhesion and splicing
         criteria, insulation type and securement methods, product delivery, storage and handling guidelines, and
         applicable installation of all materials and details.




603336 – Versico LiveRoof System - 1/2008                                                                          7
Note: Overlayment of field membrane splices will not be required when splices are shingled to avoid
               bucking of water. If field splices will buck water or if they are located in areas of ponded water,
               they shall be overlaid. Use 6" wide VersiGard Pressure-Sensitive Cured Cover Strip for
               VersiGard EPDM and 6" wide VersiWeld Pressure-Sensitive Cover Strip for VersiWeld TPO
               membrane.

B.       Flashing/detailing at walls, curbs, skylights and all other penetrations through the membrane must be
         flashed in accordance with Versico’s published specifications/details for the applicable membrane
         specified.

3.02     INSTALLATION OF 40-MIL GEOMEMBRANE SLIP SHEET

Installed prior to installation of the LiveRoof modules and after Versico’s inspection of the membrane
system.

A.       Sweep all debris, foreign material, etc. from the membrane surface.

B.       Unroll 40-mil GeoMembrane Slip Sheet directly over the membrane and provide a minimum 2" side
         and end overlap. When VersiWeld TPO membrane is used, Geomembrane sheets shall be field welded a
         minimum of 1-1/2" in width using a Heat Welder. As an option for VersiGard EPDM membranes, QA
         Seam Tape/V-150 or LV-600 Primer can be used to splice adjoining slip sheets.

C.       Extend GeoMembrane up walls, curbs, etc. to the height of the top of the growth media layer.

D.       Under windy conditions, provide temporary ballast to prevent wind disturbance. It is recommended to
         install the additional LiveRoof modules over the GeoMembrane soon after its placement to prevent
         disturbance.

3.03     APPLICATION OF LiveRoof MODULES

Unless otherwise accepted by Versico, LiveRoof modules shall be installed between April 1st and October 15th,
but not when the temperature is below freezing temperatures.

A.       Remove all debris from the slip sheet surface.

B.       Remove any plastic wrap from the modules to prevent from overheating in the sun.

C.       Installation of the Versico LiveRoof modules shall follow the installation of any irrigation system, pavers,
         ballast, and edging.

D.       Versico LiveRoof module rows shall be straight, modules shall be tight against each other, arranged in
         proper directional orientation, and Soil Elevators™ removed only when individual modules are
         completely surrounded by edging or other LiveRoof modules, so as to prevent soil spillage.

         Note: If the biodegradable Soil Elevator is used, then the Soil Elevator™ should remain in place.

E.       The installation of the Versico LiveRoof modules shall be conducted in accordance with the applicable
         landscape design.

F.       Place LiveRoof modules over the slip sheet in the desired locations as indicated on the shop drawings.

         Note: Care must be exercised when placing modules to avoid damaging the slip sheet or underlying
               membrane. Do not drag modules into position. Modules must be lifted and gently positioned.
               Do not set LiveRoof modules on top of soil, dirt, or grit. Sweep protective membrane clean in
               advance of placing each LiveRoof module.
603336 – Versico LiveRoof System - 1/2008                                                                          8
G.       Do not install modules over saturated roof surfaces or under freezing conditions.

H.       Any custom fitting and cutting against edgings or parapets must also include the underlayment of the
         LiveRoof module (40-mil GeoMembrane slip sheet) along with an appropriate drainage fabric/media
         filter. The drainage fabric must be placed under the altered module and tight across the face of the cut
         module (equal to the top of module) and placed tight against the surrounding parapet or edge treatment.

I.       After installing the modules, they should be watered immediately to thoroughly moisten the planting
         media from top to bottom.

         Note: Approximately 1 inch of water or 1-1/2 gallons of water is needed per module to moisten each
               module thoroughly.

3.04     MAINTENANCE

Maintenance is the responsibility of the building owner. There are maintenance services that can be arranged by
Versico, or the owner may choose to use an outside firm or their own staff. In all cases, the requirements outlined
below must be followed:

A.       Documentation

         Record all green roof maintenance events. Include name of person, date and activity.
         1.       If fertilizer, record type and amount applied per 1000sf
         2.       If soil test, record lab
         3.       If irrigation, duration and quantity

B.       Annual Maintenance

         1.       Soil Testing and Fertilization.

                  During April 1 to 15 of each year, administer an annual soil test for PH and fertility levels.

                  a.       Maintain pH in the range of 6.5 to 8.0. In the event that pH is outside of the 6.5 to 8.0
                           range, consult LiveRoof, LLC for the appropriate amendment.

                  b.       Maintain fertility in the normal range using a typical field soil fertility test as provided by
                           A&L labs. When indicated, apply a single springtime application of Nutricote 14 14 14,
                           Type 180 (180 day release period), at 20 lbs per 1000 sf. Follow the Nutricote labeled
                           directions for application rate, which take priority over any recommendations listed here.
                           Runoff potential does exist and should be evaluated by the applicator in accord with the
                           site specifics; the greater the runoff sensitivity, the lower the application rate. All
                           applications of fertilizer are the sole responsibility of the applicator.

C.       Irrigation

         1.       Watering

                  While in northern North America, successive watering may not be needed to keep your
                  LiveRoof® alive; however, protracted hot dry weather can result in plant thinning or death. In
                  warmer climates, depending upon rainfall and exposure, regular irrigation will probably be
                  required. Accordingly, LiveRoof® recommends irrigation, in a manner practical and efficient for
                  the scale of the installation, as a “temporary” management tool under the following conditions:


603336 – Versico LiveRoof System - 1/2008                                                                               9
a.       Prolonged hot dry weather, in the northern temperate zone, is generally defined as
                           periods of 75-degree weather, with less than 1" of rainfall persisting for 4 weeks or
                           longer. This time period will likely be less if the temperatures are hotter, the climate
                           warmer, on sloping rooftops, or roofs exposed to strong winds. Such conditions can dry
                           out the green roof substrate and cause the plants to go dormant or in extreme cases to dry
                           up and die. Dormant plants tend to shrink to a smaller size and expose soil, which can
                           predispose the system to weed encroachment.

                           When hot dry weather persists for greater than 4 weeks, irrigation is to be applied,
                           temporarily, to re-wet the soil to the point of runoff.

                           NOTE: There are no absolutes when it comes to irrigation. Check the plants for wilting
                           in the morning rather than midday. Irrigate if the plants show signs of wilting in the
                           morning.

                  b.       In areas of reflected light, such as next to south facing walls, more frequent irrigation
                           should be applied to keep the soil from becoming excessively dry.

D.       Inspections and Plant Care Protocol

         Conduct the following EVERY 2 WEEKS (twice per month) during the entire Spring through Fall
         Growing Season. Conduct year round in climatic regions where the LiveRoof does not freeze in winter.

         1.       Conduct hand weeding during the bimonthly inspection. Pull all weeds, never allow any weed to
                  flower, set seed and complete its life cycle.

                  a.       The interval may be adjusted in accord with seasonal variations in weed growth, but the
                           interval should never exceed 2 weeks or long enough to allow for weeds to flower and set
                           seed.

                  b.       Never allow a woody plant to establish in a green roof system as their root systems are
                           extensive and can damage roof membranes.

                  c.       Herbicides, whether pre-emergent or post-emergent, are not recommended as they are not
                           healthy for the environment and can contaminate runoff. A need for pre-emergent
                           herbicides is a sign of weeding too infrequently.

         2.       Displaced Soil

                  Any soil displaced, typically due to nesting birds, should be immediately replaced with LiveRoof
                  Engineered Green Roof Soil.

         3.       Drainage Inspection

                  Roof drains should be cleared of any debris, pebbles, leaves, etc. during the twice-monthly
                  inspection to keep drains flowing freely.

         4.       Debris / Trash Removal

                  Remove immediately debris or trash during bimonthly inspection. Especially during fall and
                  spring, rake LiveRoof® planting clean of any matted tree leaves to prevent smothering.




603336 – Versico LiveRoof System - 1/2008                                                                              10
5.        Pesticides

                   Pesticide use is discouraged and should always be considered secondary to cultural and biological
                   control measures, as pesticides can get into runoff water and cause environmental damage.
                   Pesticide use should only be conducted by qualified and licensed applicators, and on an “as
                   needed” basis. All applications of pesticides are the sole responsibility of the applicator.

          6.        Mowing

                    Once annually, around April 1, mow the green roof to a height of 2" or less. The clippings should
                    stay on the roof. Do not bag and remove. As an option, the owner may elect to forego the
                    mowing. USE PROTECTIVE EQUIPMENT.




                                                   Copyright 2008 Versico Incorporated

                                    VersiGard and VersiWeld are Trademarks of Versico Incorporated

                      LiveRoof and Soil Elevator are a Trademarks of LiveRoof, LLC, a subsidiary of Hortech, Inc.

                                       Permaloc is a Registered Trademark of Permaloc Corporation

This specification represents the applicable information available at the time of its publication. Owners, specifiers and Versico authorized
roofing contractors should consult Versico or their Versico Manufacturer’s Representative for any information that has subsequently been
made available.

Review the appropriate Versico warranty for specific warranty coverage, terms, conditions, and limitations.



603336 – Versico LiveRoof System - 1/2008                                                                                               11

Weitere ähnliche Inhalte

Ähnlich wie Versico Live Roof System

ENDUROFLOOR Installation Manual
ENDUROFLOOR Installation ManualENDUROFLOOR Installation Manual
ENDUROFLOOR Installation ManualFolk James
 
WPM 002 Australian version
WPM 002 Australian versionWPM 002 Australian version
WPM 002 Australian versionnandu_raga
 
Engineering & piping design
Engineering & piping designEngineering & piping design
Engineering & piping designjisothomas
 
Frp engineering piping design
Frp engineering piping designFrp engineering piping design
Frp engineering piping designDadan Yupi Andika
 
1.Enviro Span Installation Guide
1.Enviro Span Installation Guide1.Enviro Span Installation Guide
1.Enviro Span Installation GuideMike Rae
 
Legacy Shield General Product Information
Legacy Shield General Product InformationLegacy Shield General Product Information
Legacy Shield General Product InformationJason Wilke
 
Plastifloor Park Deck Waterproofing System_Flyer
Plastifloor Park Deck Waterproofing System_FlyerPlastifloor Park Deck Waterproofing System_Flyer
Plastifloor Park Deck Waterproofing System_FlyerPlasti-Chemie GmbH
 
Prefabricated Vertical Drains (PVD) method statement
Prefabricated Vertical Drains  (PVD) method statementPrefabricated Vertical Drains  (PVD) method statement
Prefabricated Vertical Drains (PVD) method statementKhaza Ahmed Palash
 
DualProof Brochure
DualProof BrochureDualProof Brochure
DualProof BrochureSURFASOLOGY
 
En au v_kassettendach nr.8112.260 02.17
En au v_kassettendach nr.8112.260 02.17En au v_kassettendach nr.8112.260 02.17
En au v_kassettendach nr.8112.260 02.17bert vanden eynde
 
Installation Instructions for CULTEC Stormwater Management Systems
Installation Instructions for CULTEC Stormwater Management SystemsInstallation Instructions for CULTEC Stormwater Management Systems
Installation Instructions for CULTEC Stormwater Management SystemsGina Carolan
 
Matrix Oil & Gas Profile
Matrix Oil & Gas ProfileMatrix Oil & Gas Profile
Matrix Oil & Gas Profilebencrouch
 
0-GG010-MZ711-00020 Scaffolding Procedure rev.1 .docx
0-GG010-MZ711-00020 Scaffolding Procedure rev.1 .docx0-GG010-MZ711-00020 Scaffolding Procedure rev.1 .docx
0-GG010-MZ711-00020 Scaffolding Procedure rev.1 .docxKaty A. Beitia G.
 
Crawford Tracey AIA Course: Glazing Design
Crawford Tracey AIA Course: Glazing DesignCrawford Tracey AIA Course: Glazing Design
Crawford Tracey AIA Course: Glazing DesignDonovan and Associates
 

Ähnlich wie Versico Live Roof System (20)

Spec u kon fsi 2021
Spec u kon fsi 2021Spec u kon fsi 2021
Spec u kon fsi 2021
 
ENDUROFLOOR Installation Manual
ENDUROFLOOR Installation ManualENDUROFLOOR Installation Manual
ENDUROFLOOR Installation Manual
 
Hdpe sealing sheet specification
Hdpe sealing sheet specificationHdpe sealing sheet specification
Hdpe sealing sheet specification
 
Fosroc waterproofing-brochure (1)
Fosroc waterproofing-brochure (1)Fosroc waterproofing-brochure (1)
Fosroc waterproofing-brochure (1)
 
WPM 002 Australian version
WPM 002 Australian versionWPM 002 Australian version
WPM 002 Australian version
 
Engineering & piping design
Engineering & piping designEngineering & piping design
Engineering & piping design
 
Frp engineering piping design
Frp engineering piping designFrp engineering piping design
Frp engineering piping design
 
1.Enviro Span Installation Guide
1.Enviro Span Installation Guide1.Enviro Span Installation Guide
1.Enviro Span Installation Guide
 
Legacy Shield General Product Information
Legacy Shield General Product InformationLegacy Shield General Product Information
Legacy Shield General Product Information
 
Dow filmtec-bw30-4040
Dow filmtec-bw30-4040Dow filmtec-bw30-4040
Dow filmtec-bw30-4040
 
Plastifloor Park Deck Waterproofing System_Flyer
Plastifloor Park Deck Waterproofing System_FlyerPlastifloor Park Deck Waterproofing System_Flyer
Plastifloor Park Deck Waterproofing System_Flyer
 
Prefabricated Vertical Drains (PVD) method statement
Prefabricated Vertical Drains  (PVD) method statementPrefabricated Vertical Drains  (PVD) method statement
Prefabricated Vertical Drains (PVD) method statement
 
DualProof Brochure
DualProof BrochureDualProof Brochure
DualProof Brochure
 
En au v_kassettendach nr.8112.260 02.17
En au v_kassettendach nr.8112.260 02.17En au v_kassettendach nr.8112.260 02.17
En au v_kassettendach nr.8112.260 02.17
 
Installation Instructions for CULTEC Stormwater Management Systems
Installation Instructions for CULTEC Stormwater Management SystemsInstallation Instructions for CULTEC Stormwater Management Systems
Installation Instructions for CULTEC Stormwater Management Systems
 
Matrix Oil & Gas Profile
Matrix Oil & Gas ProfileMatrix Oil & Gas Profile
Matrix Oil & Gas Profile
 
Practical Assessment 1 - Install horizontal weatherboards
Practical Assessment 1 - Install horizontal weatherboardsPractical Assessment 1 - Install horizontal weatherboards
Practical Assessment 1 - Install horizontal weatherboards
 
0-GG010-MZ711-00020 Scaffolding Procedure rev.1 .docx
0-GG010-MZ711-00020 Scaffolding Procedure rev.1 .docx0-GG010-MZ711-00020 Scaffolding Procedure rev.1 .docx
0-GG010-MZ711-00020 Scaffolding Procedure rev.1 .docx
 
Crawford Tracey AIA Course: Glazing Design
Crawford Tracey AIA Course: Glazing DesignCrawford Tracey AIA Course: Glazing Design
Crawford Tracey AIA Course: Glazing Design
 
5288PS2i1
5288PS2i15288PS2i1
5288PS2i1
 

Mehr von Flanna489y

Earth Pledge Installs Green Roof
Earth Pledge Installs Green RoofEarth Pledge Installs Green Roof
Earth Pledge Installs Green RoofFlanna489y
 
Eco Roofs Portland Oregon: Questions and Answers
Eco Roofs Portland Oregon: Questions and AnswersEco Roofs Portland Oregon: Questions and Answers
Eco Roofs Portland Oregon: Questions and AnswersFlanna489y
 
Eco Roof Resource List - City of Portland
Eco Roof Resource List - City of PortlandEco Roof Resource List - City of Portland
Eco Roof Resource List - City of PortlandFlanna489y
 
Evergreen Roof Gardens Brochure
Evergreen Roof Gardens BrochureEvergreen Roof Gardens Brochure
Evergreen Roof Gardens BrochureFlanna489y
 
Extensive Roof Garden
Extensive Roof GardenExtensive Roof Garden
Extensive Roof GardenFlanna489y
 
Feasibility Study for Green Roof - Queen’s University Campus
Feasibility Study for Green Roof - Queen’s University CampusFeasibility Study for Green Roof - Queen’s University Campus
Feasibility Study for Green Roof - Queen’s University CampusFlanna489y
 
Filtration Green Roof
Filtration Green RoofFiltration Green Roof
Filtration Green RoofFlanna489y
 
Gardening in the Sky - San Francisco CA
Gardening in the Sky - San Francisco CAGardening in the Sky - San Francisco CA
Gardening in the Sky - San Francisco CAFlanna489y
 
Green Building Resource Guide for Residential Construction - Build It Green
Green Building Resource Guide for Residential Construction - Build It GreenGreen Building Resource Guide for Residential Construction - Build It Green
Green Building Resource Guide for Residential Construction - Build It GreenFlanna489y
 
Green Building Sources - Rocky Mountain Institute
Green Building Sources - Rocky Mountain InstituteGreen Building Sources - Rocky Mountain Institute
Green Building Sources - Rocky Mountain InstituteFlanna489y
 
GREEN ROOF ADVISORY GROUP, Austin TX
GREEN ROOF ADVISORY GROUP, Austin TXGREEN ROOF ADVISORY GROUP, Austin TX
GREEN ROOF ADVISORY GROUP, Austin TXFlanna489y
 
Green Roof at Summit United Methodist Church - Service Learning Project
Green Roof at Summit United Methodist Church - Service Learning ProjectGreen Roof at Summit United Methodist Church - Service Learning Project
Green Roof at Summit United Methodist Church - Service Learning ProjectFlanna489y
 
Green Roof in the Desert
Green Roof in the DesertGreen Roof in the Desert
Green Roof in the DesertFlanna489y
 
Green Roof Proposal and Guide - Athens, GA
Green Roof Proposal and Guide - Athens, GAGreen Roof Proposal and Guide - Athens, GA
Green Roof Proposal and Guide - Athens, GAFlanna489y
 
Green Roof Resources - Seattle
Green Roof Resources - SeattleGreen Roof Resources - Seattle
Green Roof Resources - SeattleFlanna489y
 
Green Roof: The Next Urban Frontier - Bronx NY
Green Roof: The Next Urban Frontier - Bronx NYGreen Roof: The Next Urban Frontier - Bronx NY
Green Roof: The Next Urban Frontier - Bronx NYFlanna489y
 
Green Roofs for Indoor Climate Control
Green Roofs for Indoor Climate ControlGreen Roofs for Indoor Climate Control
Green Roofs for Indoor Climate ControlFlanna489y
 
Green Roofs in Washington, DC - The Green Build-out Model
Green Roofs in Washington, DC - The Green Build-out ModelGreen Roofs in Washington, DC - The Green Build-out Model
Green Roofs in Washington, DC - The Green Build-out ModelFlanna489y
 
Green Roofs: A Primer, by Heather Ellis
Green Roofs: A Primer, by Heather EllisGreen Roofs: A Primer, by Heather Ellis
Green Roofs: A Primer, by Heather EllisFlanna489y
 
Green Roofs: Imrpoving Stream Water Quality
Green Roofs: Imrpoving Stream Water QualityGreen Roofs: Imrpoving Stream Water Quality
Green Roofs: Imrpoving Stream Water QualityFlanna489y
 

Mehr von Flanna489y (20)

Earth Pledge Installs Green Roof
Earth Pledge Installs Green RoofEarth Pledge Installs Green Roof
Earth Pledge Installs Green Roof
 
Eco Roofs Portland Oregon: Questions and Answers
Eco Roofs Portland Oregon: Questions and AnswersEco Roofs Portland Oregon: Questions and Answers
Eco Roofs Portland Oregon: Questions and Answers
 
Eco Roof Resource List - City of Portland
Eco Roof Resource List - City of PortlandEco Roof Resource List - City of Portland
Eco Roof Resource List - City of Portland
 
Evergreen Roof Gardens Brochure
Evergreen Roof Gardens BrochureEvergreen Roof Gardens Brochure
Evergreen Roof Gardens Brochure
 
Extensive Roof Garden
Extensive Roof GardenExtensive Roof Garden
Extensive Roof Garden
 
Feasibility Study for Green Roof - Queen’s University Campus
Feasibility Study for Green Roof - Queen’s University CampusFeasibility Study for Green Roof - Queen’s University Campus
Feasibility Study for Green Roof - Queen’s University Campus
 
Filtration Green Roof
Filtration Green RoofFiltration Green Roof
Filtration Green Roof
 
Gardening in the Sky - San Francisco CA
Gardening in the Sky - San Francisco CAGardening in the Sky - San Francisco CA
Gardening in the Sky - San Francisco CA
 
Green Building Resource Guide for Residential Construction - Build It Green
Green Building Resource Guide for Residential Construction - Build It GreenGreen Building Resource Guide for Residential Construction - Build It Green
Green Building Resource Guide for Residential Construction - Build It Green
 
Green Building Sources - Rocky Mountain Institute
Green Building Sources - Rocky Mountain InstituteGreen Building Sources - Rocky Mountain Institute
Green Building Sources - Rocky Mountain Institute
 
GREEN ROOF ADVISORY GROUP, Austin TX
GREEN ROOF ADVISORY GROUP, Austin TXGREEN ROOF ADVISORY GROUP, Austin TX
GREEN ROOF ADVISORY GROUP, Austin TX
 
Green Roof at Summit United Methodist Church - Service Learning Project
Green Roof at Summit United Methodist Church - Service Learning ProjectGreen Roof at Summit United Methodist Church - Service Learning Project
Green Roof at Summit United Methodist Church - Service Learning Project
 
Green Roof in the Desert
Green Roof in the DesertGreen Roof in the Desert
Green Roof in the Desert
 
Green Roof Proposal and Guide - Athens, GA
Green Roof Proposal and Guide - Athens, GAGreen Roof Proposal and Guide - Athens, GA
Green Roof Proposal and Guide - Athens, GA
 
Green Roof Resources - Seattle
Green Roof Resources - SeattleGreen Roof Resources - Seattle
Green Roof Resources - Seattle
 
Green Roof: The Next Urban Frontier - Bronx NY
Green Roof: The Next Urban Frontier - Bronx NYGreen Roof: The Next Urban Frontier - Bronx NY
Green Roof: The Next Urban Frontier - Bronx NY
 
Green Roofs for Indoor Climate Control
Green Roofs for Indoor Climate ControlGreen Roofs for Indoor Climate Control
Green Roofs for Indoor Climate Control
 
Green Roofs in Washington, DC - The Green Build-out Model
Green Roofs in Washington, DC - The Green Build-out ModelGreen Roofs in Washington, DC - The Green Build-out Model
Green Roofs in Washington, DC - The Green Build-out Model
 
Green Roofs: A Primer, by Heather Ellis
Green Roofs: A Primer, by Heather EllisGreen Roofs: A Primer, by Heather Ellis
Green Roofs: A Primer, by Heather Ellis
 
Green Roofs: Imrpoving Stream Water Quality
Green Roofs: Imrpoving Stream Water QualityGreen Roofs: Imrpoving Stream Water Quality
Green Roofs: Imrpoving Stream Water Quality
 

Kürzlich hochgeladen

Employee wellbeing at the workplace.pptx
Employee wellbeing at the workplace.pptxEmployee wellbeing at the workplace.pptx
Employee wellbeing at the workplace.pptxNirmalaLoungPoorunde1
 
Concept of Vouching. B.Com(Hons) /B.Compdf
Concept of Vouching. B.Com(Hons) /B.CompdfConcept of Vouching. B.Com(Hons) /B.Compdf
Concept of Vouching. B.Com(Hons) /B.CompdfUmakantAnnand
 
Science 7 - LAND and SEA BREEZE and its Characteristics
Science 7 - LAND and SEA BREEZE and its CharacteristicsScience 7 - LAND and SEA BREEZE and its Characteristics
Science 7 - LAND and SEA BREEZE and its CharacteristicsKarinaGenton
 
Paris 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activityParis 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activityGeoBlogs
 
MENTAL STATUS EXAMINATION format.docx
MENTAL     STATUS EXAMINATION format.docxMENTAL     STATUS EXAMINATION format.docx
MENTAL STATUS EXAMINATION format.docxPoojaSen20
 
PSYCHIATRIC History collection FORMAT.pptx
PSYCHIATRIC   History collection FORMAT.pptxPSYCHIATRIC   History collection FORMAT.pptx
PSYCHIATRIC History collection FORMAT.pptxPoojaSen20
 
Q4-W6-Restating Informational Text Grade 3
Q4-W6-Restating Informational Text Grade 3Q4-W6-Restating Informational Text Grade 3
Q4-W6-Restating Informational Text Grade 3JemimahLaneBuaron
 
microwave assisted reaction. General introduction
microwave assisted reaction. General introductionmicrowave assisted reaction. General introduction
microwave assisted reaction. General introductionMaksud Ahmed
 
Accessible design: Minimum effort, maximum impact
Accessible design: Minimum effort, maximum impactAccessible design: Minimum effort, maximum impact
Accessible design: Minimum effort, maximum impactdawncurless
 
Presiding Officer Training module 2024 lok sabha elections
Presiding Officer Training module 2024 lok sabha electionsPresiding Officer Training module 2024 lok sabha elections
Presiding Officer Training module 2024 lok sabha electionsanshu789521
 
Industrial Policy - 1948, 1956, 1973, 1977, 1980, 1991
Industrial Policy - 1948, 1956, 1973, 1977, 1980, 1991Industrial Policy - 1948, 1956, 1973, 1977, 1980, 1991
Industrial Policy - 1948, 1956, 1973, 1977, 1980, 1991RKavithamani
 
Sanyam Choudhary Chemistry practical.pdf
Sanyam Choudhary Chemistry practical.pdfSanyam Choudhary Chemistry practical.pdf
Sanyam Choudhary Chemistry practical.pdfsanyamsingh5019
 
Micromeritics - Fundamental and Derived Properties of Powders
Micromeritics - Fundamental and Derived Properties of PowdersMicromeritics - Fundamental and Derived Properties of Powders
Micromeritics - Fundamental and Derived Properties of PowdersChitralekhaTherkar
 
Introduction to ArtificiaI Intelligence in Higher Education
Introduction to ArtificiaI Intelligence in Higher EducationIntroduction to ArtificiaI Intelligence in Higher Education
Introduction to ArtificiaI Intelligence in Higher Educationpboyjonauth
 
_Math 4-Q4 Week 5.pptx Steps in Collecting Data
_Math 4-Q4 Week 5.pptx Steps in Collecting Data_Math 4-Q4 Week 5.pptx Steps in Collecting Data
_Math 4-Q4 Week 5.pptx Steps in Collecting DataJhengPantaleon
 
How to Make a Pirate ship Primary Education.pptx
How to Make a Pirate ship Primary Education.pptxHow to Make a Pirate ship Primary Education.pptx
How to Make a Pirate ship Primary Education.pptxmanuelaromero2013
 
Measures of Central Tendency: Mean, Median and Mode
Measures of Central Tendency: Mean, Median and ModeMeasures of Central Tendency: Mean, Median and Mode
Measures of Central Tendency: Mean, Median and ModeThiyagu K
 

Kürzlich hochgeladen (20)

Employee wellbeing at the workplace.pptx
Employee wellbeing at the workplace.pptxEmployee wellbeing at the workplace.pptx
Employee wellbeing at the workplace.pptx
 
Concept of Vouching. B.Com(Hons) /B.Compdf
Concept of Vouching. B.Com(Hons) /B.CompdfConcept of Vouching. B.Com(Hons) /B.Compdf
Concept of Vouching. B.Com(Hons) /B.Compdf
 
Science 7 - LAND and SEA BREEZE and its Characteristics
Science 7 - LAND and SEA BREEZE and its CharacteristicsScience 7 - LAND and SEA BREEZE and its Characteristics
Science 7 - LAND and SEA BREEZE and its Characteristics
 
Paris 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activityParis 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activity
 
Código Creativo y Arte de Software | Unidad 1
Código Creativo y Arte de Software | Unidad 1Código Creativo y Arte de Software | Unidad 1
Código Creativo y Arte de Software | Unidad 1
 
Staff of Color (SOC) Retention Efforts DDSD
Staff of Color (SOC) Retention Efforts DDSDStaff of Color (SOC) Retention Efforts DDSD
Staff of Color (SOC) Retention Efforts DDSD
 
MENTAL STATUS EXAMINATION format.docx
MENTAL     STATUS EXAMINATION format.docxMENTAL     STATUS EXAMINATION format.docx
MENTAL STATUS EXAMINATION format.docx
 
PSYCHIATRIC History collection FORMAT.pptx
PSYCHIATRIC   History collection FORMAT.pptxPSYCHIATRIC   History collection FORMAT.pptx
PSYCHIATRIC History collection FORMAT.pptx
 
Q4-W6-Restating Informational Text Grade 3
Q4-W6-Restating Informational Text Grade 3Q4-W6-Restating Informational Text Grade 3
Q4-W6-Restating Informational Text Grade 3
 
microwave assisted reaction. General introduction
microwave assisted reaction. General introductionmicrowave assisted reaction. General introduction
microwave assisted reaction. General introduction
 
Accessible design: Minimum effort, maximum impact
Accessible design: Minimum effort, maximum impactAccessible design: Minimum effort, maximum impact
Accessible design: Minimum effort, maximum impact
 
Model Call Girl in Bikash Puri Delhi reach out to us at 🔝9953056974🔝
Model Call Girl in Bikash Puri  Delhi reach out to us at 🔝9953056974🔝Model Call Girl in Bikash Puri  Delhi reach out to us at 🔝9953056974🔝
Model Call Girl in Bikash Puri Delhi reach out to us at 🔝9953056974🔝
 
Presiding Officer Training module 2024 lok sabha elections
Presiding Officer Training module 2024 lok sabha electionsPresiding Officer Training module 2024 lok sabha elections
Presiding Officer Training module 2024 lok sabha elections
 
Industrial Policy - 1948, 1956, 1973, 1977, 1980, 1991
Industrial Policy - 1948, 1956, 1973, 1977, 1980, 1991Industrial Policy - 1948, 1956, 1973, 1977, 1980, 1991
Industrial Policy - 1948, 1956, 1973, 1977, 1980, 1991
 
Sanyam Choudhary Chemistry practical.pdf
Sanyam Choudhary Chemistry practical.pdfSanyam Choudhary Chemistry practical.pdf
Sanyam Choudhary Chemistry practical.pdf
 
Micromeritics - Fundamental and Derived Properties of Powders
Micromeritics - Fundamental and Derived Properties of PowdersMicromeritics - Fundamental and Derived Properties of Powders
Micromeritics - Fundamental and Derived Properties of Powders
 
Introduction to ArtificiaI Intelligence in Higher Education
Introduction to ArtificiaI Intelligence in Higher EducationIntroduction to ArtificiaI Intelligence in Higher Education
Introduction to ArtificiaI Intelligence in Higher Education
 
_Math 4-Q4 Week 5.pptx Steps in Collecting Data
_Math 4-Q4 Week 5.pptx Steps in Collecting Data_Math 4-Q4 Week 5.pptx Steps in Collecting Data
_Math 4-Q4 Week 5.pptx Steps in Collecting Data
 
How to Make a Pirate ship Primary Education.pptx
How to Make a Pirate ship Primary Education.pptxHow to Make a Pirate ship Primary Education.pptx
How to Make a Pirate ship Primary Education.pptx
 
Measures of Central Tendency: Mean, Median and Mode
Measures of Central Tendency: Mean, Median and ModeMeasures of Central Tendency: Mean, Median and Mode
Measures of Central Tendency: Mean, Median and Mode
 

Versico Live Roof System

  • 1. Versico LiveRoof® System Table of Contents January 2008 Page Part I - General 1.01 Description .............................................................................................................................3 1.02 Extensive (Shallow) Green Roof Definition ..........................................................................3 1.03 Design Guidelines ..................................................................................................................3 1.04 Quality Assurance ..................................................................................................................4 1.05 Submittals...............................................................................................................................4 1.06 Warranty.................................................................................................................................5 1.07 Job Conditions........................................................................................................................5 Part II - Products 2.01 General ...................................................................................................................................5 2.02 Versico LiveRoof Module Specifications ..............................................................................5 2.03 Related Versico Materials ......................................................................................................6 2.04 Growth Media Properties .......................................................................................................6 2.05 Plants ......................................................................................................................................7 2.06 Edge Elements........................................................................................................................7 2.07 “Hardscape” Items (Optional) ................................................................................................7 Part III - Execution 3.01 General ...................................................................................................................................7 3.02 Installation of 40-Mil Geomembrane Slip Sheet....................................................................8 3.03 Application of LiveRoof Modules .........................................................................................8 3.04 Maintenance ...........................................................................................................................9 Details 603336 – Versico LiveRoof System - 1/2008
  • 2. Versico LiveRoof® System January 2008 PART 1 GENERAL 1.01 DESCRIPTION The Versico LiveRoof® System incorporates pre-planted, pre-grown “module trays” in lieu of traditional components used above an adhered roofing membrane (i.e., drainage boards, root barriers, moisture mats, and growth media). The roofing membrane may consist of VersiGard® (black) non-reinforced or reinforced EPDM membrane or VersiWeld® TPO membrane. The type of membrane is dependent upon the length of warranty selected. Refer to Paragraph 1.03, Design Guidelines, for specific requirements. The “module trays” are lightweight, composed of recycled plastics (100% post industrial recycled polypropylene), with walls 100-mils thick, and arrive at the building site ready for installation. Standard tray size is 1' x 2' x 3- 1/4" with 4-1/4" soil depth. For information about the LiveRoof modules, weights, planting types, and growth media, refer to Part 2, Products. 1.02 EXTENSIVE (SHALLOW) GREEN ROOF DEFINITION A shallow planting system (using 3-1/4" tall LiveRoof tray modules) pre-planted and pre-grown to a height of approximately 4-1/4" using an engineered blend of inorganic and organic components. The growing media types are chosen for the specific climate zone and the anticipated weight above the membrane assembly is approximately 27-29 pounds per square foot. 1.03 DESIGN GUIDELINES A. For 10 or 15-year warranties, the assembly requires the use of 60-mil EPDM or 60-mil TPO installed in an adhered fashion. B. For 20-year warranties, the assembly requires the use of 75-mil VersiGard Reinforced EPDM or 72-mil VersiWeld TPO installed in an adhered fashion. C. An EPDM or TPO membrane shall be fully adhered, typically to polyisocyanurate insulation, with layers of insulation set in adhesive. As an option, bottom layers of insulation can be mechanically fastened to the roof deck with the top layer set in adhesive. D. Refer to Versico’s specifications for specific requirements concerning membrane adhesion and splicing criteria, insulation type and securement methods, product delivery, storage and handling guidelines, and applicable installation of all materials and details. E. To facilitate drainage, a minimum roof slope of 1/4" in 12" must be provided at the waterproofing membrane level. 603336 – Versico LiveRoof System - 1/2008 3
  • 3. F. The Versico LiveRoof System shall not be installed on projects over 50' in height. Projects in excess of 50' must be forwarded to Versico for review prior to bid and installation. G. Proper decking shall be provided by the building owner. The building owner or its designated representative must ensure the building structure is investigated by a registered engineer to ensure its ability to withstand the total weight of the specified roofing system, as well as construction loads and live loads, in accordance with all applicable codes. The specifier must also designate the maximum allowable weight and location for material loading and storage on the roof. H. The installation season for the LiveRoof system will vary based upon the local climate. LiveRoof modules may be installed when all of the following conditions are met: 1. The roof is frost- and ice-free 2. The plant material has been properly cold- or heat/sun- acclimatized at the LiveRoof nursery 3. The soil within the modules is unfrozen 4. The LiveRoof modules are vegetated with 95% coverage or greater. I. Prior to installing the LiveRoof modules, a black 40-mil GeoMembrane slip sheet shall be installed over the roofing membrane at all areas where the modules will be placed. When VersiWeld TPO membrane is used, Geomembrane sheets shall be field welded a minimum of 1-1/2" in width using a Heat Welder. As an option for VersiGard EPDM membranes, QA Seam Tape/V-150 or LV-600 Primer can be used to splice adjoining slip sheets. J. When trays are to be installed in high wind areas, Versico should be contacted regarding appropriate methods to prevent tray movement and/or soil media wind erosion. 1.04 QUALITY ASSURANCE A. A pre-installation meeting should be coordinated by the specifier and attended by the LiveRoof installer, the roofing applicator, membrane manufacturer’s representative and other trades working on the roof system both before and after membrane installation. The purpose of this meeting is to discuss the necessity of ensuring proper membrane protection during all phases of installation and to review other applicable requirements or unusual field conditions. B. Upon request by the Authorized Applicator, an inspection will be conducted by a Field Service Representative of Versico to ascertain that the membrane roofing system has been installed according to Versico's specifications and details. This inspection shall be coordinated prior to installing the LiveRoof components (40-mil GeoMembrane slip sheet and the LiveRoof modules) so access to the membrane is not impaired. Note: The roofing applicator must notify Versico at least 3 weeks in advance of applicable inspection dates for coordination purposes. C. A final inspection will be conducted after application of the LiveRoof modules to ensure proper installation. D. Flood testing, electronic testing, or other leak detection means are strongly advised to check the waterproof integrity of the membrane prior to installing the LiveRoof components (black 40-mil GeoMembrane slip sheet and the LiveRoof modules). 1.05 SUBMITTALS A. To ensure compliance with Versico's warranty requirements, all projects should be forwarded to Versico for review prior to installation. 603336 – Versico LiveRoof System - 1/2008 4
  • 4. B. A dimensioned layout of LiveRoof modules and all field splices shall be included along with the project submittals (shop drawing and Request for Warranty). C. For all projects, prior to project inspection by Versico, a final shop drawing must be approved by Versico. 1.06 WARRANTY A. A 10, 15 or 20-year System Warranty is available for a charge on commercial buildings and applies only to products manufactured or marketed by Versico Incorporated. The membrane system is defined as membrane, flashings, adhesives, sealants, and other Versico brand products utilized in this installation. For a complete description of these products, refer to the “Products Section” or the applicable “Attachment” in the Versico specifications. B. The formation or presence of mold or fungi in a building is dependent upon a broad range of factors including, but not limited to, the presence of spores and nutrient sources, moisture, temperatures, climatic conditions, relative humidity, and heating/ventilating systems and their maintenance and operating capabilities. These factors are beyond the control of Versico and Versico shall not be responsible for any claims, repairs, restoration or damages relating to the presence of any irritants, contaminants, vapors, fumes, molds, fungi, bacteria, spores, mycotoxins, or the like in any building or in the air, land, or water serving the building. 1.07 JOB CONDITIONS A. Coordination between various trades is essential to avoid unnecessary rooftop traffic over sections of the roof and to prevent damage to the membrane. Heavily traveled areas must be protected by placing temporary protection courses to prevent damage to the membrane. B. The use of a vapor retarder to protect insulation and reduce moisture accumulation within an insulated roofing assembly should be investigated by the specifier. Consult the latest publications by ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.) and NRCA (National Roofing Contractors Association) for specific information. PART 2 PRODUCTS 2.01 GENERAL The components of this roofing system are to be products of Versico. The installation, performance, or integrity of products by others is not the responsibility of Versico and is expressly disclaimed by the Versico Warranty. 2.02 VERSICO LiveRoof® MODULE SPECIFICATIONS LiveRoof modules are black in color and formed with 100-mil thick (sidewall) polypropylene. Modules are pre- planted with growth media and plant species of the color and type desired by the building owner. LiveRoof modules are pre-grown to maturity (95%+ soil coverage). Each tray also contains a Soil Elevator™, an insert collar that allows soil to be packaged above the edge of the module. The Soil Elevator is removed after the modules are installed to promote a continuous media appearance. Physical properties are as follows: 603336 – Versico LiveRoof System - 1/2008 5
  • 5. Element Description Depth of Standard Modules 3-1/4" Soil Depth Approx. 4-1/4" Module Size 1' x 2' Weight of Planted Modules (fully saturated weights) 27 – 29 lb. per sq. ft., fully saturated Module Material 100% post industrial recycled polypropylene Module Clearance above Roofing Surface 0.5" Color of Modules Black Growth Media Engineered blend consisting of organic and inorganic components. Required underlayment for modules Black, 40-mil GeoMembrane slip sheet Typically not required for LiveRoof Standard Modules, but recommended for backup during prolonged, hot, dry, windy Irrigation System weather patterns; an overhead irrigation type system is recommended, when specified. An overhead system designed by Spring Brook Supply is recommended. Plants See individual grower recommendations for regional selections Wood, recycled composite wood, aluminum, pavers or other Edge Treatment specialty materials. Co-engineered Permaloc® non-fastened, aluminum, L-shaped edging is recommended. 2.03 RELATED VERSICO MATERIALS A. For use with VersiGard EPDM membrane – G200SA Yellow Substrate Adhesive, VersiGard QA Seam Tape, Primer, Lap Sealant, Cured EPDM Flashing, Pressure-Sensitive Flashing, T-Joint Covers, Uncured Flashing, Fasteners/Plates, Water Cut-Off Mastic, Pourable Sealer, Pre-Molded Pipe Seals, Pressure- Sensitive Inside/Outside Corner, Pourable Sealer Pockets, and Termination Bars. B. For use with VersiWeld TPO membrane – VersiWeld Bonding Adhesive, Cut-Edge Sealant, reinforced and non-reinforced flashing, Water Cut-Off Mastic, PT 304 Sealant, Molded Pocket Sealant, Weathered Membrane Cleaner, Pre-Molded Pipe Seals, Split Pipe Boots, Curb Wrap Corners, and Termination Bars. C. 40-mil GeoMembrane Slip Sheet (black) – a heat-weldable, non-reinforced, polypropylene sheet designed for liners in potable water and industrial containment applications. The membrane is specifically formulated for long-term use in buried or exposed geomembrane applications. Available in rolls 12' wide by 100' long. D. Other Versico products, such as insulation and edgings/copings, are also required when such components are to be included as part of the System Warranty. 2.04 GROWTH MEDIA PROPERTIES The Growth Media mix provides stable soil structure, high porosity, and high moisture holding properties. The growth media also provides excellent drainage while remaining lightweight. LiveRoof® media is an engineered blend of inorganic and organic components based upon the fine side of German FLL guidelines modified so as to contain ecologically sustainable levels of organic content. LiveRoof® specified engineered soil is 93+% (by dry weight) inorganic content for minimal shrinkage/decomposition. 603336 – Versico LiveRoof System - 1/2008 6
  • 6. 2.05 PLANTS LiveRoof recommended design mix of highly drought resistant ground covers that can thrive in an extensive/shallow environment based on the project location. Local horticulturists should be consulted for specific recommendations. A. Planting density: 95% coverage at the time of shipment. B. Special Order: Specific plantings that meet the climate zone and the desired look the roof garden is to achieve. Special patterns may be accomplished with various plant species to give a pattern look for color, plant height, etc. This is accomplished by coordinating a specific design with the owner/architect and LiveRoof grower. 2.06 EDGE ELEMENTS Consisting of aluminum with perforations for drainage for placement at exposed edges of the modules. Edging is 4.5" x 3", with a minimum gauge of 210-mil. LiveRoof recommends co-engineered Permaloc® non-fastened, perforated aluminum, L-shaped edging. A. Edging is required for use between modules and stone ballast. B. Edging is preferred, but not required, for use between modules and concrete, recycled glass, or rubber pavers. C. If walkway pads are used in place of pavers, use 10 x 16 x 1" wafer head self-tapping screws to affix edging to the modules to prevent slippage. 2.07 “HARDSCAPE” ITEMS (optional) A. Individual concrete plaza pavers – 2' x 2' x 2" thick precast concrete pavers weighing a minimum of 18 psf with a minimum compressive strength of 6500 psi. B. Paver Pedestals – Rubber paver pedestals to elevate the surface of the pavers above the roof membrane and promote positive drainage and protection from freeze/thaw. C. Versico Rubber Paver – A 2' x 2' x 2" thick rubber paver weighing approximately 24 pounds per unit (6 pounds per square foot) manufactured from recycled rubber, which provides a resilient, shock absorbing, weather resistant surface. Available in colors of terre cotta (red) and black. Optional sizes and colors are also available. D. Stone Ballast – Nominal 1-1/2" diameter rounded water worn gravel which conforms with ASTM D448, gradation size #4, applied at a minimum of 10 pounds per square foot. Used around roof drains and along walls as a transition from the modules and to promote drainage. PART 3 EXECUTION 3.01 GENERAL A. Refer to Versico’s specifications for specific requirements concerning membrane adhesion and splicing criteria, insulation type and securement methods, product delivery, storage and handling guidelines, and applicable installation of all materials and details. 603336 – Versico LiveRoof System - 1/2008 7
  • 7. Note: Overlayment of field membrane splices will not be required when splices are shingled to avoid bucking of water. If field splices will buck water or if they are located in areas of ponded water, they shall be overlaid. Use 6" wide VersiGard Pressure-Sensitive Cured Cover Strip for VersiGard EPDM and 6" wide VersiWeld Pressure-Sensitive Cover Strip for VersiWeld TPO membrane. B. Flashing/detailing at walls, curbs, skylights and all other penetrations through the membrane must be flashed in accordance with Versico’s published specifications/details for the applicable membrane specified. 3.02 INSTALLATION OF 40-MIL GEOMEMBRANE SLIP SHEET Installed prior to installation of the LiveRoof modules and after Versico’s inspection of the membrane system. A. Sweep all debris, foreign material, etc. from the membrane surface. B. Unroll 40-mil GeoMembrane Slip Sheet directly over the membrane and provide a minimum 2" side and end overlap. When VersiWeld TPO membrane is used, Geomembrane sheets shall be field welded a minimum of 1-1/2" in width using a Heat Welder. As an option for VersiGard EPDM membranes, QA Seam Tape/V-150 or LV-600 Primer can be used to splice adjoining slip sheets. C. Extend GeoMembrane up walls, curbs, etc. to the height of the top of the growth media layer. D. Under windy conditions, provide temporary ballast to prevent wind disturbance. It is recommended to install the additional LiveRoof modules over the GeoMembrane soon after its placement to prevent disturbance. 3.03 APPLICATION OF LiveRoof MODULES Unless otherwise accepted by Versico, LiveRoof modules shall be installed between April 1st and October 15th, but not when the temperature is below freezing temperatures. A. Remove all debris from the slip sheet surface. B. Remove any plastic wrap from the modules to prevent from overheating in the sun. C. Installation of the Versico LiveRoof modules shall follow the installation of any irrigation system, pavers, ballast, and edging. D. Versico LiveRoof module rows shall be straight, modules shall be tight against each other, arranged in proper directional orientation, and Soil Elevators™ removed only when individual modules are completely surrounded by edging or other LiveRoof modules, so as to prevent soil spillage. Note: If the biodegradable Soil Elevator is used, then the Soil Elevator™ should remain in place. E. The installation of the Versico LiveRoof modules shall be conducted in accordance with the applicable landscape design. F. Place LiveRoof modules over the slip sheet in the desired locations as indicated on the shop drawings. Note: Care must be exercised when placing modules to avoid damaging the slip sheet or underlying membrane. Do not drag modules into position. Modules must be lifted and gently positioned. Do not set LiveRoof modules on top of soil, dirt, or grit. Sweep protective membrane clean in advance of placing each LiveRoof module. 603336 – Versico LiveRoof System - 1/2008 8
  • 8. G. Do not install modules over saturated roof surfaces or under freezing conditions. H. Any custom fitting and cutting against edgings or parapets must also include the underlayment of the LiveRoof module (40-mil GeoMembrane slip sheet) along with an appropriate drainage fabric/media filter. The drainage fabric must be placed under the altered module and tight across the face of the cut module (equal to the top of module) and placed tight against the surrounding parapet or edge treatment. I. After installing the modules, they should be watered immediately to thoroughly moisten the planting media from top to bottom. Note: Approximately 1 inch of water or 1-1/2 gallons of water is needed per module to moisten each module thoroughly. 3.04 MAINTENANCE Maintenance is the responsibility of the building owner. There are maintenance services that can be arranged by Versico, or the owner may choose to use an outside firm or their own staff. In all cases, the requirements outlined below must be followed: A. Documentation Record all green roof maintenance events. Include name of person, date and activity. 1. If fertilizer, record type and amount applied per 1000sf 2. If soil test, record lab 3. If irrigation, duration and quantity B. Annual Maintenance 1. Soil Testing and Fertilization. During April 1 to 15 of each year, administer an annual soil test for PH and fertility levels. a. Maintain pH in the range of 6.5 to 8.0. In the event that pH is outside of the 6.5 to 8.0 range, consult LiveRoof, LLC for the appropriate amendment. b. Maintain fertility in the normal range using a typical field soil fertility test as provided by A&L labs. When indicated, apply a single springtime application of Nutricote 14 14 14, Type 180 (180 day release period), at 20 lbs per 1000 sf. Follow the Nutricote labeled directions for application rate, which take priority over any recommendations listed here. Runoff potential does exist and should be evaluated by the applicator in accord with the site specifics; the greater the runoff sensitivity, the lower the application rate. All applications of fertilizer are the sole responsibility of the applicator. C. Irrigation 1. Watering While in northern North America, successive watering may not be needed to keep your LiveRoof® alive; however, protracted hot dry weather can result in plant thinning or death. In warmer climates, depending upon rainfall and exposure, regular irrigation will probably be required. Accordingly, LiveRoof® recommends irrigation, in a manner practical and efficient for the scale of the installation, as a “temporary” management tool under the following conditions: 603336 – Versico LiveRoof System - 1/2008 9
  • 9. a. Prolonged hot dry weather, in the northern temperate zone, is generally defined as periods of 75-degree weather, with less than 1" of rainfall persisting for 4 weeks or longer. This time period will likely be less if the temperatures are hotter, the climate warmer, on sloping rooftops, or roofs exposed to strong winds. Such conditions can dry out the green roof substrate and cause the plants to go dormant or in extreme cases to dry up and die. Dormant plants tend to shrink to a smaller size and expose soil, which can predispose the system to weed encroachment. When hot dry weather persists for greater than 4 weeks, irrigation is to be applied, temporarily, to re-wet the soil to the point of runoff. NOTE: There are no absolutes when it comes to irrigation. Check the plants for wilting in the morning rather than midday. Irrigate if the plants show signs of wilting in the morning. b. In areas of reflected light, such as next to south facing walls, more frequent irrigation should be applied to keep the soil from becoming excessively dry. D. Inspections and Plant Care Protocol Conduct the following EVERY 2 WEEKS (twice per month) during the entire Spring through Fall Growing Season. Conduct year round in climatic regions where the LiveRoof does not freeze in winter. 1. Conduct hand weeding during the bimonthly inspection. Pull all weeds, never allow any weed to flower, set seed and complete its life cycle. a. The interval may be adjusted in accord with seasonal variations in weed growth, but the interval should never exceed 2 weeks or long enough to allow for weeds to flower and set seed. b. Never allow a woody plant to establish in a green roof system as their root systems are extensive and can damage roof membranes. c. Herbicides, whether pre-emergent or post-emergent, are not recommended as they are not healthy for the environment and can contaminate runoff. A need for pre-emergent herbicides is a sign of weeding too infrequently. 2. Displaced Soil Any soil displaced, typically due to nesting birds, should be immediately replaced with LiveRoof Engineered Green Roof Soil. 3. Drainage Inspection Roof drains should be cleared of any debris, pebbles, leaves, etc. during the twice-monthly inspection to keep drains flowing freely. 4. Debris / Trash Removal Remove immediately debris or trash during bimonthly inspection. Especially during fall and spring, rake LiveRoof® planting clean of any matted tree leaves to prevent smothering. 603336 – Versico LiveRoof System - 1/2008 10
  • 10. 5. Pesticides Pesticide use is discouraged and should always be considered secondary to cultural and biological control measures, as pesticides can get into runoff water and cause environmental damage. Pesticide use should only be conducted by qualified and licensed applicators, and on an “as needed” basis. All applications of pesticides are the sole responsibility of the applicator. 6. Mowing Once annually, around April 1, mow the green roof to a height of 2" or less. The clippings should stay on the roof. Do not bag and remove. As an option, the owner may elect to forego the mowing. USE PROTECTIVE EQUIPMENT. Copyright 2008 Versico Incorporated VersiGard and VersiWeld are Trademarks of Versico Incorporated LiveRoof and Soil Elevator are a Trademarks of LiveRoof, LLC, a subsidiary of Hortech, Inc. Permaloc is a Registered Trademark of Permaloc Corporation This specification represents the applicable information available at the time of its publication. Owners, specifiers and Versico authorized roofing contractors should consult Versico or their Versico Manufacturer’s Representative for any information that has subsequently been made available. Review the appropriate Versico warranty for specific warranty coverage, terms, conditions, and limitations. 603336 – Versico LiveRoof System - 1/2008 11