DOE docket: EERE–2011–BT–NOA–004


              Sherwin Comments on DOE Commercial Building Asset Rating Program

           Suggestions from Elton Sherwin, venture capitalist and author of Addicted to Energy:
                   Innovative Advanced Energy Saving Features
                  As a venture capitalist, one of my major concerns with asset ratings is they ignore
           innovation. New products, technical breakthroughs and some design innovations are usually
           omitted from asset ratings.
                   Recommendation: Encourage architects to itemize advanced energy saving features in
           the rating report. They do not need to influence the asset rating score. This provides a register
           for innovative assets and will encouragement invention and experimentation.1


                                   Responses to Specific Questions in the RFI
           Rating Scale:
                   First choice: Match the ENERGY STAR score. A new scoring methodology will
           create confusion in the industry (even if it is better).
                  Second choice. A scaled, inverted BTU/sq. foot score. See recommendations in
            Energy Efficiency and Sustainable Design Standards for New Federal Buildings: pages 46-47.


           Source vs. Site:
                   Use the same methodology as ENERGY STAR (national source energy).
           Carbon footprint calculations:
                   Please avoid giving buildings extra points based on their utility’s energy mix.


           Quality Assurance and Third Party Validation:
                   As an investor my other major concern with asset ratings is their accuracy. The best
           quality assurance guarantee is to require disclose actual EUIs, Energy Star scores, and input
           worksheets.
                  Require all building owners who publically disclose their Asset Rating also disclose
           their EUI and Energy Star score. It should be a condition of use.
                          For buildings with Asset Scores below their Energy Star rating, do not require
                           additional validation. The high ENERGY STAR score validates the AR score.
                          For buildings with Asset Ratings above their Energy Star Rating, require outside
                           validation.
                          For new buildings: Require a commitment to disclose future EUI and Energy
                           Star rating as long as the Asset Rating is used publically.
                          For buildings with Asset Ratings in the top 25%, require complete
                           transparency of the input worksheet: Post it on the DOE website. Disclose the
                           buildings attributes that generated the high rating. This will discourage gaming.

                   1                      Comments on EERE–2011–BT–NOA–004
DOE docket: EERE–2011–BT–NOA–004


              Sherwin Comments on DOE Commercial Building Asset Rating Program

           Additional Recommendations:
                       During the pilot: Validate that the most predictive building attributes are
                        used. Statistically correlate the input worksheets with actual energy consumption.
                           o Collect the four additional data elements used by the Portfolio Manager and
                               automatically calculate the EUI and ENERGY STAR rating.
                       Require dual labeling. For existing buildings: Include the prior year’s ENERGY
                        STAR score on the Asset Rating label. (as build/as used)

           What Are the Assets That Should Be Rated?
                  Over a dozen asset rating methodologies have been tried in the US and all struggle to
           accurately predict energy use. Yet some building professionals can walk through an empty
           building and predict energy consumption. What are they looking for?
                   Having studied the input worksheets for several failed
           European rating systems, I observe that they omit many of these              Buildings with high
           assets that the professionals look for. Having interviewed hundreds           numbers of T12s,
           of building professionals, these are the building assets most               MR-16s, and Edison-
           predictive of energy consumption:                                            socket ceiling cans
                                                                                          are often poor
           Basic Assets
                                                                                            performers
           Total Building Energy Demand
                       Electrical interconnect size (1,000 amp service, 10,000 amp service, etc.) Buildings
                        with large master breaker boxes tend to use more power.
                       Total horsepower of all hardwired, fixed-speed motors, pumps, fans, and
                        compressors. (Fixed-speed pumps, fans and compressors can be responsible for
                        more than half the non-plug load electricity consumption in a building.)2

           Lighting Efficiency
                       Total number of hardwired lighting fixtures3
                       Total number of hardwired sockets supporting Edison, MR16, and GU16 bases4
                       Total number of T12 bulbs5
                       Number of occupancy sensors (more is better).
                       Number of light level sensors that control light output (daylight harvesting)6

           Basic HVAC
                       Total tons of A/C capacity (maximum)                           Oversized HVAC
                       Number of cooling towers                                      systems are usually
                       Number of A/C compressors                                    wasteful, regardless of
                       Maximum total BTU’s of heating from combustion                  rated efficiency
                       Total number of thermostats and temperature sensors
                       Total horsepower of all air-handling fans. (lower is better)
                       Percent of HVAC outside air goes through a heat exchanger (economizer)

                   2                       Comments on EERE–2011–BT–NOA–004
DOE docket: EERE–2011–BT–NOA–004


              Sherwin Comments on DOE Commercial Building Asset Rating Program
                         During normal operations, when air enters occupied space, how many different
                          velocity settings are there? 1, 2, 3 or more? (more is better)7

           Windows
                         Percent of exterior walls that are windows.
                         Estimated percent of south and west-facing glass exposed to the sun at 3pm in Aug.
                         Total sq. ft. of exterior window shades (excluding the north side of the building)
                         Percent of exterior rooms with operable windows8
                  Professionals pay attention to these items. Please ensure the new DOE system does not
               omit them.

           Additional Metrics
                   These more advanced metrics are in addition to those already mentioned. While there is
           some redundancy among these items, I would encourage you to test and correlate the following
           during the pilot. They may improve the accuracy of the asset rating. If they don’t, then the
           simpler metrics above should suffice.

           HVAC                                                                             Fixed-speed fans are
                         Maximum total air handling capacity (cubic feet/min.)9             the telltale asset of
                         Number of occupancy sensors on the HVAC system                        an inefficient
                         Percent of A/C units that are variable output or multi-stage         HVAC system
                         Are furnaces and boilers modulating?
                         Maximum energy required to drive all air handlers and fans10
                         Minimum airflow average. In conditioned space, when the HVAC system is moving
                          air, what is the minimum amount of air it can move in a typical room?
                         Make, model and specifications of compressors, boilers and furnaces.
                         What percentage of rooms with exterior walls have individual zones?
                         Submeters installed on compressors, boilers and cooling towers.11

           Total Building Energy Demand
                         Submeters installed for each floor?12
                         Monitors installed capable of user feedback of energy consumption per room?13

           Lighting
                         Percent of ceiling fixtures controlled by occupancy or daylight sensors14
                         Percent of rooms with individual occupancy sensors
                         Percent of the lighting fixtures in areas with access to daylight automatically dim
                          when daylight is present.

           Windows                                                                     Solar heat gain in one
                                                                                           room usually
                         Accurate solar heat gain calculations.
                                                                                         increases energy
                         Make, model and specifications of the windows
                                                                                        consumption many
                                                                                              rooms
                      3                      Comments on EERE–2011–BT–NOA–004
DOE docket: EERE–2011–BT–NOA–004


              Sherwin Comments on DOE Commercial Building Asset Rating Program

                    1
                      Innovative Advanced Energy Saving Features might include: Thermoelectric windows, white roofs, solar
           cooling, energy monitoring systems, feedback devices, humidity monitors, CO2 monitors, user-control of ceiling
           fixtures, advance building control systems. I would to help develop a starter list. This could include both a
           predefined list and a freeform “other” field.
                    2
                      A Grunfos Alpha is a good example of an adaptive pump that reduces energy consumption by 60 to 80%.
           Also, see Addicted to Energy pages 49 and footnotes 41 to 44.
                    3
                       If a lighting fixture is installed, it will be used. The more lighting fixtures a building has, the more
           electricity it uses.
                    4
                      Alternatively: Total number of incandescent bulbs in permanent fixtures (non-fluorescent, non-LED light
           fixtures hardwired including halogen fixtures, MR 16s, ceiling cans, etc.) Also, see the next footnote
                    5
                     Why not count LEDs, T5s and T8s? This number can be inferred: Once the total number of fixtures is
           counted, subtract the fixtures that need to be replaced: T12, Edison bases, the other incandescent bases.
                    This is how the many energy pros do it. Look to see how many fixtures are on the ceiling and how many of
           them are candidates for replacement (T12s and incandescent fixtures).
                    6
                      This is a proxy for best-in-class digital ballasts. Buildings with great lighting systems have digital ballasts
           that adjust to light levels.
                    7
                      Audit pros, when they walk through a building, look for spots where they can feel air moving. This is a
           one of the key telltale attributes of an overactive, inefficient HVAC system. This “candle flicker” test is hard to
           write into a spec, but, in general, buildings that have large fans and blow air at one speed are much less efficient than
           buildings with smaller multispeed fans. Total HVAC energy consumption can decline dramatically as air movement
           is reduced.
                    8
                    In some climates and for some building types exterior windows are a predictor of building energy
           consumption.
                    9
                    This is the total ACH including fresh and stale air. This metric usually gives an advantage to
           displacement air systems.
                    10
                        The previous section had “the total horsepower of all air-handling fans” (nameplate). This metric is
           similar, but different and harder number to come by. This is total kilowatts used by all air handlers when they are
           on. It is a better measure of efficiency, but it may not be worth the extra effort. It might be worth allowing the
           nameplate number to be entered as the default and optionally allowing building owners to enter actuals, which
           would make sense for high efficiency fans. It is possible that simply identifying which motors are variable speed
           will be predictive enough. That is why the second item on in Total Building Energy Demand is Total Horsepower of
           all fixed-speed motors.
                    11
                      These do not need to be utility submeters. Another way to say this: Is the hardware installed to monitor
           the energy consumption of the building’s major subsystems. Buildings with these “submeters” use less energy.
                    Also, see next note:
                    12
                       Some would argue that the existence of submeters is part of an operational rating. They are not. The
           installation of submeters not scored in Energy Star or any other operational rating. The installation of submeters is a
           key attribute (asset) of a building. If the architect specifies submeters, the building will, on average, use less
           energy.
                    13
                         See previous note.
                    14
                      These are sensors activated by people or photons. This includes manual timers that require users to turn
           on with each use (countdown timers) which are a form of occupancy sensors. This does not include time-of-day
           clocks without occupancy or light level sensors. This does not include building control systems that rely solely on
           time of day.



                    4                             Comments on EERE–2011–BT–NOA–004

Weitere ähnliche Inhalte

Mehr von Elton Sherwin

The Bible and Homosexuality, Part 1: Sodom and Gomorrah and the Old Testament...
The Bible and Homosexuality, Part 1: Sodom and Gomorrah and the Old Testament...The Bible and Homosexuality, Part 1: Sodom and Gomorrah and the Old Testament...
The Bible and Homosexuality, Part 1: Sodom and Gomorrah and the Old Testament...Elton Sherwin
 
The Bible and Homosexuality, Part 2: The 7 Scriptures Blessing Sexual Minorities
The Bible and Homosexuality, Part 2: The 7 Scriptures Blessing Sexual MinoritiesThe Bible and Homosexuality, Part 2: The 7 Scriptures Blessing Sexual Minorities
The Bible and Homosexuality, Part 2: The 7 Scriptures Blessing Sexual MinoritiesElton Sherwin
 
LGBTQ in Scripture Part 3: New Testament Clobber Verses
LGBTQ in Scripture Part 3: New Testament Clobber VersesLGBTQ in Scripture Part 3: New Testament Clobber Verses
LGBTQ in Scripture Part 3: New Testament Clobber VersesElton Sherwin
 
10 Ways to Lower Your Carbon Footprint
10 Ways to Lower Your Carbon Footprint10 Ways to Lower Your Carbon Footprint
10 Ways to Lower Your Carbon FootprintElton Sherwin
 
Earth Day 2014 - a Christian Perspective
Earth Day 2014 - a Christian PerspectiveEarth Day 2014 - a Christian Perspective
Earth Day 2014 - a Christian PerspectiveElton Sherwin
 
Climate Change in 7 slides
Climate Change in 7 slides Climate Change in 7 slides
Climate Change in 7 slides Elton Sherwin
 
SHOULD YOU TAKE YOUR CHILD SOMEPLACE DANGEROUS?
SHOULD YOU TAKE YOUR CHILD SOMEPLACE DANGEROUS?SHOULD YOU TAKE YOUR CHILD SOMEPLACE DANGEROUS?
SHOULD YOU TAKE YOUR CHILD SOMEPLACE DANGEROUS?Elton Sherwin
 
Solutions to Climate Change Rotary Holiday
Solutions to Climate Change Rotary HolidaySolutions to Climate Change Rotary Holiday
Solutions to Climate Change Rotary HolidayElton Sherwin
 
Haiti Deforestation - A Short Update
Haiti Deforestation - A Short UpdateHaiti Deforestation - A Short Update
Haiti Deforestation - A Short UpdateElton Sherwin
 
Why Methane Matters: The Need for World-wide Monitoring of Methane
Why Methane Matters: The Need for World-wide Monitoring of MethaneWhy Methane Matters: The Need for World-wide Monitoring of Methane
Why Methane Matters: The Need for World-wide Monitoring of MethaneElton Sherwin
 
Reducing Large Electric Bills
Reducing Large Electric BillsReducing Large Electric Bills
Reducing Large Electric BillsElton Sherwin
 
Job Creation: Three Things Government Can Do
Job Creation: Three Things Government Can DoJob Creation: Three Things Government Can Do
Job Creation: Three Things Government Can DoElton Sherwin
 
Twelve Secrets of Silicon Valley
Twelve Secrets of Silicon ValleyTwelve Secrets of Silicon Valley
Twelve Secrets of Silicon ValleyElton Sherwin
 
Creating Green Jobs - The Sherwin Plan
Creating Green Jobs - The Sherwin PlanCreating Green Jobs - The Sherwin Plan
Creating Green Jobs - The Sherwin PlanElton Sherwin
 
Building Ratings - London vs. New York
Building Ratings - London vs. New YorkBuilding Ratings - London vs. New York
Building Ratings - London vs. New YorkElton Sherwin
 
How Thermal Storage Can Save the Grid
How Thermal Storage Can Save the GridHow Thermal Storage Can Save the Grid
How Thermal Storage Can Save the GridElton Sherwin
 
Building Ratings: Do the Europeans or Americans Have It Right?
Building Ratings: Do the Europeans or Americans Have It Right?Building Ratings: Do the Europeans or Americans Have It Right?
Building Ratings: Do the Europeans or Americans Have It Right?Elton Sherwin
 
Australian Crops, Flooding and Locusts in 2010
Australian Crops, Flooding and Locusts in 2010Australian Crops, Flooding and Locusts in 2010
Australian Crops, Flooding and Locusts in 2010Elton Sherwin
 
Uncle Sam Wants You – In the War Against Climate Change
Uncle Sam Wants You – In the War Against Climate ChangeUncle Sam Wants You – In the War Against Climate Change
Uncle Sam Wants You – In the War Against Climate ChangeElton Sherwin
 
WHAT SHOULD THE GOVERNOR DO ABOUT JOBS Sherwin keynote at 2010 Game Changers ...
WHAT SHOULD THE GOVERNOR DO ABOUT JOBS Sherwin keynote at 2010 Game Changers ...WHAT SHOULD THE GOVERNOR DO ABOUT JOBS Sherwin keynote at 2010 Game Changers ...
WHAT SHOULD THE GOVERNOR DO ABOUT JOBS Sherwin keynote at 2010 Game Changers ...Elton Sherwin
 

Mehr von Elton Sherwin (20)

The Bible and Homosexuality, Part 1: Sodom and Gomorrah and the Old Testament...
The Bible and Homosexuality, Part 1: Sodom and Gomorrah and the Old Testament...The Bible and Homosexuality, Part 1: Sodom and Gomorrah and the Old Testament...
The Bible and Homosexuality, Part 1: Sodom and Gomorrah and the Old Testament...
 
The Bible and Homosexuality, Part 2: The 7 Scriptures Blessing Sexual Minorities
The Bible and Homosexuality, Part 2: The 7 Scriptures Blessing Sexual MinoritiesThe Bible and Homosexuality, Part 2: The 7 Scriptures Blessing Sexual Minorities
The Bible and Homosexuality, Part 2: The 7 Scriptures Blessing Sexual Minorities
 
LGBTQ in Scripture Part 3: New Testament Clobber Verses
LGBTQ in Scripture Part 3: New Testament Clobber VersesLGBTQ in Scripture Part 3: New Testament Clobber Verses
LGBTQ in Scripture Part 3: New Testament Clobber Verses
 
10 Ways to Lower Your Carbon Footprint
10 Ways to Lower Your Carbon Footprint10 Ways to Lower Your Carbon Footprint
10 Ways to Lower Your Carbon Footprint
 
Earth Day 2014 - a Christian Perspective
Earth Day 2014 - a Christian PerspectiveEarth Day 2014 - a Christian Perspective
Earth Day 2014 - a Christian Perspective
 
Climate Change in 7 slides
Climate Change in 7 slides Climate Change in 7 slides
Climate Change in 7 slides
 
SHOULD YOU TAKE YOUR CHILD SOMEPLACE DANGEROUS?
SHOULD YOU TAKE YOUR CHILD SOMEPLACE DANGEROUS?SHOULD YOU TAKE YOUR CHILD SOMEPLACE DANGEROUS?
SHOULD YOU TAKE YOUR CHILD SOMEPLACE DANGEROUS?
 
Solutions to Climate Change Rotary Holiday
Solutions to Climate Change Rotary HolidaySolutions to Climate Change Rotary Holiday
Solutions to Climate Change Rotary Holiday
 
Haiti Deforestation - A Short Update
Haiti Deforestation - A Short UpdateHaiti Deforestation - A Short Update
Haiti Deforestation - A Short Update
 
Why Methane Matters: The Need for World-wide Monitoring of Methane
Why Methane Matters: The Need for World-wide Monitoring of MethaneWhy Methane Matters: The Need for World-wide Monitoring of Methane
Why Methane Matters: The Need for World-wide Monitoring of Methane
 
Reducing Large Electric Bills
Reducing Large Electric BillsReducing Large Electric Bills
Reducing Large Electric Bills
 
Job Creation: Three Things Government Can Do
Job Creation: Three Things Government Can DoJob Creation: Three Things Government Can Do
Job Creation: Three Things Government Can Do
 
Twelve Secrets of Silicon Valley
Twelve Secrets of Silicon ValleyTwelve Secrets of Silicon Valley
Twelve Secrets of Silicon Valley
 
Creating Green Jobs - The Sherwin Plan
Creating Green Jobs - The Sherwin PlanCreating Green Jobs - The Sherwin Plan
Creating Green Jobs - The Sherwin Plan
 
Building Ratings - London vs. New York
Building Ratings - London vs. New YorkBuilding Ratings - London vs. New York
Building Ratings - London vs. New York
 
How Thermal Storage Can Save the Grid
How Thermal Storage Can Save the GridHow Thermal Storage Can Save the Grid
How Thermal Storage Can Save the Grid
 
Building Ratings: Do the Europeans or Americans Have It Right?
Building Ratings: Do the Europeans or Americans Have It Right?Building Ratings: Do the Europeans or Americans Have It Right?
Building Ratings: Do the Europeans or Americans Have It Right?
 
Australian Crops, Flooding and Locusts in 2010
Australian Crops, Flooding and Locusts in 2010Australian Crops, Flooding and Locusts in 2010
Australian Crops, Flooding and Locusts in 2010
 
Uncle Sam Wants You – In the War Against Climate Change
Uncle Sam Wants You – In the War Against Climate ChangeUncle Sam Wants You – In the War Against Climate Change
Uncle Sam Wants You – In the War Against Climate Change
 
WHAT SHOULD THE GOVERNOR DO ABOUT JOBS Sherwin keynote at 2010 Game Changers ...
WHAT SHOULD THE GOVERNOR DO ABOUT JOBS Sherwin keynote at 2010 Game Changers ...WHAT SHOULD THE GOVERNOR DO ABOUT JOBS Sherwin keynote at 2010 Game Changers ...
WHAT SHOULD THE GOVERNOR DO ABOUT JOBS Sherwin keynote at 2010 Game Changers ...
 

Kürzlich hochgeladen

9990771857 Call Girls in Dwarka Sector 08 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 08 Delhi (Call Girls) Delhi9990771857 Call Girls in Dwarka Sector 08 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 08 Delhi (Call Girls) Delhidelhimodel235
 
9990771857 Call Girls in Dwarka Sector 137 Noida (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 137 Noida (Call Girls) Delhi9990771857 Call Girls in Dwarka Sector 137 Noida (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 137 Noida (Call Girls) Delhidelhimodel235
 
Greater Vancouver Realtors Statistics Package April 2024
Greater Vancouver Realtors Statistics Package April 2024Greater Vancouver Realtors Statistics Package April 2024
Greater Vancouver Realtors Statistics Package April 2024VickyAulakh1
 
BPTP THE AMAARIO Luxury Project Invest Like Royalty in Sector 37D Gurgaon Dwa...
BPTP THE AMAARIO Luxury Project Invest Like Royalty in Sector 37D Gurgaon Dwa...BPTP THE AMAARIO Luxury Project Invest Like Royalty in Sector 37D Gurgaon Dwa...
BPTP THE AMAARIO Luxury Project Invest Like Royalty in Sector 37D Gurgaon Dwa...ApartmentWala1
 
M3M The Line Brochure - Premium Investment Opportunity for Commercial Ventures
M3M The Line Brochure - Premium Investment Opportunity for Commercial VenturesM3M The Line Brochure - Premium Investment Opportunity for Commercial Ventures
M3M The Line Brochure - Premium Investment Opportunity for Commercial Venturessheltercareglobal
 
BPTP THE AMAARIO For The Royals Of Tomorrow in Sector 37D Gurgaon Dwarka Expr...
BPTP THE AMAARIO For The Royals Of Tomorrow in Sector 37D Gurgaon Dwarka Expr...BPTP THE AMAARIO For The Royals Of Tomorrow in Sector 37D Gurgaon Dwarka Expr...
BPTP THE AMAARIO For The Royals Of Tomorrow in Sector 37D Gurgaon Dwarka Expr...ApartmentWala1
 
9990771857 Call Girls Dwarka Sector 8 Delhi (Call Girls ) Delhi
9990771857 Call Girls  Dwarka Sector 8 Delhi (Call Girls ) Delhi9990771857 Call Girls  Dwarka Sector 8 Delhi (Call Girls ) Delhi
9990771857 Call Girls Dwarka Sector 8 Delhi (Call Girls ) Delhidelhimodel235
 
Kohinoor Hinjewadi Phase 2 Pune E-Brochure.pdf
Kohinoor Hinjewadi Phase 2 Pune  E-Brochure.pdfKohinoor Hinjewadi Phase 2 Pune  E-Brochure.pdf
Kohinoor Hinjewadi Phase 2 Pune E-Brochure.pdfManishSaxena95
 
9990771857 Call Girls in Dwarka Sector 3 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 3 Delhi (Call Girls) Delhi9990771857 Call Girls in Dwarka Sector 3 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 3 Delhi (Call Girls) Delhidelhimodel235
 
2k Shots ≽ 9205541914 ≼ Call Girls In Sainik Farm (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Sainik Farm (Delhi)2k Shots ≽ 9205541914 ≼ Call Girls In Sainik Farm (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Sainik Farm (Delhi)Delhi Call girls
 
9990771857 Call Girls in Dwarka Sector 1 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 1 Delhi (Call Girls) Delhi9990771857 Call Girls in Dwarka Sector 1 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 1 Delhi (Call Girls) Delhidelhimodel235
 
BDSM⚡Call Girls in Sector 55 Noida Escorts >༒8448380779 Escort Service
BDSM⚡Call Girls in Sector 55 Noida Escorts >༒8448380779 Escort ServiceBDSM⚡Call Girls in Sector 55 Noida Escorts >༒8448380779 Escort Service
BDSM⚡Call Girls in Sector 55 Noida Escorts >༒8448380779 Escort ServiceDelhi Call girls
 
SVN Live 5.6.24 Weekly Property Broadcast
SVN Live 5.6.24 Weekly Property BroadcastSVN Live 5.6.24 Weekly Property Broadcast
SVN Live 5.6.24 Weekly Property BroadcastSVN International Corp.
 
Parksville 96 Surrey Floor Plans May 2024
Parksville 96 Surrey Floor Plans May 2024Parksville 96 Surrey Floor Plans May 2024
Parksville 96 Surrey Floor Plans May 2024VickyAulakh1
 
Enjoy Night ≽ 8448380779 ≼ Call Girls In Huda City Centre (Gurgaon)
Enjoy Night ≽ 8448380779 ≼ Call Girls In Huda City Centre (Gurgaon)Enjoy Night ≽ 8448380779 ≼ Call Girls In Huda City Centre (Gurgaon)
Enjoy Night ≽ 8448380779 ≼ Call Girls In Huda City Centre (Gurgaon)Delhi Call girls
 
Enjoy Night ≽ 8448380779 ≼ Call Girls In Iffco Chowk (Gurgaon)
Enjoy Night ≽ 8448380779 ≼ Call Girls In Iffco Chowk (Gurgaon)Enjoy Night ≽ 8448380779 ≼ Call Girls In Iffco Chowk (Gurgaon)
Enjoy Night ≽ 8448380779 ≼ Call Girls In Iffco Chowk (Gurgaon)Delhi Call girls
 
9990771857 Call Girls Dwarka Sector 9 Delhi (Call Girls ) Delhi
9990771857 Call Girls Dwarka Sector 9 Delhi (Call Girls ) Delhi9990771857 Call Girls Dwarka Sector 9 Delhi (Call Girls ) Delhi
9990771857 Call Girls Dwarka Sector 9 Delhi (Call Girls ) Delhidelhimodel235
 
ACE Terra Yamuna Expressway | 8929888700
ACE Terra Yamuna Expressway | 8929888700ACE Terra Yamuna Expressway | 8929888700
ACE Terra Yamuna Expressway | 8929888700Truhomes
 
9990771857 Call Girls in Dwarka Sector 2 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 2 Delhi (Call Girls) Delhi9990771857 Call Girls in Dwarka Sector 2 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 2 Delhi (Call Girls) Delhidelhimodel235
 

Kürzlich hochgeladen (20)

9990771857 Call Girls in Dwarka Sector 08 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 08 Delhi (Call Girls) Delhi9990771857 Call Girls in Dwarka Sector 08 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 08 Delhi (Call Girls) Delhi
 
9990771857 Call Girls in Dwarka Sector 137 Noida (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 137 Noida (Call Girls) Delhi9990771857 Call Girls in Dwarka Sector 137 Noida (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 137 Noida (Call Girls) Delhi
 
Greater Vancouver Realtors Statistics Package April 2024
Greater Vancouver Realtors Statistics Package April 2024Greater Vancouver Realtors Statistics Package April 2024
Greater Vancouver Realtors Statistics Package April 2024
 
BPTP THE AMAARIO Luxury Project Invest Like Royalty in Sector 37D Gurgaon Dwa...
BPTP THE AMAARIO Luxury Project Invest Like Royalty in Sector 37D Gurgaon Dwa...BPTP THE AMAARIO Luxury Project Invest Like Royalty in Sector 37D Gurgaon Dwa...
BPTP THE AMAARIO Luxury Project Invest Like Royalty in Sector 37D Gurgaon Dwa...
 
M3M The Line Brochure - Premium Investment Opportunity for Commercial Ventures
M3M The Line Brochure - Premium Investment Opportunity for Commercial VenturesM3M The Line Brochure - Premium Investment Opportunity for Commercial Ventures
M3M The Line Brochure - Premium Investment Opportunity for Commercial Ventures
 
BPTP THE AMAARIO For The Royals Of Tomorrow in Sector 37D Gurgaon Dwarka Expr...
BPTP THE AMAARIO For The Royals Of Tomorrow in Sector 37D Gurgaon Dwarka Expr...BPTP THE AMAARIO For The Royals Of Tomorrow in Sector 37D Gurgaon Dwarka Expr...
BPTP THE AMAARIO For The Royals Of Tomorrow in Sector 37D Gurgaon Dwarka Expr...
 
Retail Center For Sale - 1019 River St., Belleville, WI
Retail Center For Sale - 1019 River St., Belleville, WIRetail Center For Sale - 1019 River St., Belleville, WI
Retail Center For Sale - 1019 River St., Belleville, WI
 
9990771857 Call Girls Dwarka Sector 8 Delhi (Call Girls ) Delhi
9990771857 Call Girls  Dwarka Sector 8 Delhi (Call Girls ) Delhi9990771857 Call Girls  Dwarka Sector 8 Delhi (Call Girls ) Delhi
9990771857 Call Girls Dwarka Sector 8 Delhi (Call Girls ) Delhi
 
Kohinoor Hinjewadi Phase 2 Pune E-Brochure.pdf
Kohinoor Hinjewadi Phase 2 Pune  E-Brochure.pdfKohinoor Hinjewadi Phase 2 Pune  E-Brochure.pdf
Kohinoor Hinjewadi Phase 2 Pune E-Brochure.pdf
 
9990771857 Call Girls in Dwarka Sector 3 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 3 Delhi (Call Girls) Delhi9990771857 Call Girls in Dwarka Sector 3 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 3 Delhi (Call Girls) Delhi
 
2k Shots ≽ 9205541914 ≼ Call Girls In Sainik Farm (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Sainik Farm (Delhi)2k Shots ≽ 9205541914 ≼ Call Girls In Sainik Farm (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Sainik Farm (Delhi)
 
9990771857 Call Girls in Dwarka Sector 1 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 1 Delhi (Call Girls) Delhi9990771857 Call Girls in Dwarka Sector 1 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 1 Delhi (Call Girls) Delhi
 
BDSM⚡Call Girls in Sector 55 Noida Escorts >༒8448380779 Escort Service
BDSM⚡Call Girls in Sector 55 Noida Escorts >༒8448380779 Escort ServiceBDSM⚡Call Girls in Sector 55 Noida Escorts >༒8448380779 Escort Service
BDSM⚡Call Girls in Sector 55 Noida Escorts >༒8448380779 Escort Service
 
SVN Live 5.6.24 Weekly Property Broadcast
SVN Live 5.6.24 Weekly Property BroadcastSVN Live 5.6.24 Weekly Property Broadcast
SVN Live 5.6.24 Weekly Property Broadcast
 
Parksville 96 Surrey Floor Plans May 2024
Parksville 96 Surrey Floor Plans May 2024Parksville 96 Surrey Floor Plans May 2024
Parksville 96 Surrey Floor Plans May 2024
 
Enjoy Night ≽ 8448380779 ≼ Call Girls In Huda City Centre (Gurgaon)
Enjoy Night ≽ 8448380779 ≼ Call Girls In Huda City Centre (Gurgaon)Enjoy Night ≽ 8448380779 ≼ Call Girls In Huda City Centre (Gurgaon)
Enjoy Night ≽ 8448380779 ≼ Call Girls In Huda City Centre (Gurgaon)
 
Enjoy Night ≽ 8448380779 ≼ Call Girls In Iffco Chowk (Gurgaon)
Enjoy Night ≽ 8448380779 ≼ Call Girls In Iffco Chowk (Gurgaon)Enjoy Night ≽ 8448380779 ≼ Call Girls In Iffco Chowk (Gurgaon)
Enjoy Night ≽ 8448380779 ≼ Call Girls In Iffco Chowk (Gurgaon)
 
9990771857 Call Girls Dwarka Sector 9 Delhi (Call Girls ) Delhi
9990771857 Call Girls Dwarka Sector 9 Delhi (Call Girls ) Delhi9990771857 Call Girls Dwarka Sector 9 Delhi (Call Girls ) Delhi
9990771857 Call Girls Dwarka Sector 9 Delhi (Call Girls ) Delhi
 
ACE Terra Yamuna Expressway | 8929888700
ACE Terra Yamuna Expressway | 8929888700ACE Terra Yamuna Expressway | 8929888700
ACE Terra Yamuna Expressway | 8929888700
 
9990771857 Call Girls in Dwarka Sector 2 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 2 Delhi (Call Girls) Delhi9990771857 Call Girls in Dwarka Sector 2 Delhi (Call Girls) Delhi
9990771857 Call Girls in Dwarka Sector 2 Delhi (Call Girls) Delhi
 

Comments on DOE Commercial Building Asset Rating Program

  • 1. DOE docket: EERE–2011–BT–NOA–004 Sherwin Comments on DOE Commercial Building Asset Rating Program Suggestions from Elton Sherwin, venture capitalist and author of Addicted to Energy: Innovative Advanced Energy Saving Features As a venture capitalist, one of my major concerns with asset ratings is they ignore innovation. New products, technical breakthroughs and some design innovations are usually omitted from asset ratings. Recommendation: Encourage architects to itemize advanced energy saving features in the rating report. They do not need to influence the asset rating score. This provides a register for innovative assets and will encouragement invention and experimentation.1 Responses to Specific Questions in the RFI Rating Scale: First choice: Match the ENERGY STAR score. A new scoring methodology will create confusion in the industry (even if it is better). Second choice. A scaled, inverted BTU/sq. foot score. See recommendations in Energy Efficiency and Sustainable Design Standards for New Federal Buildings: pages 46-47. Source vs. Site: Use the same methodology as ENERGY STAR (national source energy). Carbon footprint calculations: Please avoid giving buildings extra points based on their utility’s energy mix. Quality Assurance and Third Party Validation: As an investor my other major concern with asset ratings is their accuracy. The best quality assurance guarantee is to require disclose actual EUIs, Energy Star scores, and input worksheets. Require all building owners who publically disclose their Asset Rating also disclose their EUI and Energy Star score. It should be a condition of use.  For buildings with Asset Scores below their Energy Star rating, do not require additional validation. The high ENERGY STAR score validates the AR score.  For buildings with Asset Ratings above their Energy Star Rating, require outside validation.  For new buildings: Require a commitment to disclose future EUI and Energy Star rating as long as the Asset Rating is used publically.  For buildings with Asset Ratings in the top 25%, require complete transparency of the input worksheet: Post it on the DOE website. Disclose the buildings attributes that generated the high rating. This will discourage gaming. 1 Comments on EERE–2011–BT–NOA–004
  • 2. DOE docket: EERE–2011–BT–NOA–004 Sherwin Comments on DOE Commercial Building Asset Rating Program Additional Recommendations:  During the pilot: Validate that the most predictive building attributes are used. Statistically correlate the input worksheets with actual energy consumption. o Collect the four additional data elements used by the Portfolio Manager and automatically calculate the EUI and ENERGY STAR rating.  Require dual labeling. For existing buildings: Include the prior year’s ENERGY STAR score on the Asset Rating label. (as build/as used) What Are the Assets That Should Be Rated? Over a dozen asset rating methodologies have been tried in the US and all struggle to accurately predict energy use. Yet some building professionals can walk through an empty building and predict energy consumption. What are they looking for? Having studied the input worksheets for several failed European rating systems, I observe that they omit many of these Buildings with high assets that the professionals look for. Having interviewed hundreds numbers of T12s, of building professionals, these are the building assets most MR-16s, and Edison- predictive of energy consumption: socket ceiling cans are often poor Basic Assets performers Total Building Energy Demand  Electrical interconnect size (1,000 amp service, 10,000 amp service, etc.) Buildings with large master breaker boxes tend to use more power.  Total horsepower of all hardwired, fixed-speed motors, pumps, fans, and compressors. (Fixed-speed pumps, fans and compressors can be responsible for more than half the non-plug load electricity consumption in a building.)2 Lighting Efficiency  Total number of hardwired lighting fixtures3  Total number of hardwired sockets supporting Edison, MR16, and GU16 bases4  Total number of T12 bulbs5  Number of occupancy sensors (more is better).  Number of light level sensors that control light output (daylight harvesting)6 Basic HVAC  Total tons of A/C capacity (maximum) Oversized HVAC  Number of cooling towers systems are usually  Number of A/C compressors wasteful, regardless of  Maximum total BTU’s of heating from combustion rated efficiency  Total number of thermostats and temperature sensors  Total horsepower of all air-handling fans. (lower is better)  Percent of HVAC outside air goes through a heat exchanger (economizer) 2 Comments on EERE–2011–BT–NOA–004
  • 3. DOE docket: EERE–2011–BT–NOA–004 Sherwin Comments on DOE Commercial Building Asset Rating Program  During normal operations, when air enters occupied space, how many different velocity settings are there? 1, 2, 3 or more? (more is better)7 Windows  Percent of exterior walls that are windows.  Estimated percent of south and west-facing glass exposed to the sun at 3pm in Aug.  Total sq. ft. of exterior window shades (excluding the north side of the building)  Percent of exterior rooms with operable windows8 Professionals pay attention to these items. Please ensure the new DOE system does not omit them. Additional Metrics These more advanced metrics are in addition to those already mentioned. While there is some redundancy among these items, I would encourage you to test and correlate the following during the pilot. They may improve the accuracy of the asset rating. If they don’t, then the simpler metrics above should suffice. HVAC Fixed-speed fans are  Maximum total air handling capacity (cubic feet/min.)9 the telltale asset of  Number of occupancy sensors on the HVAC system an inefficient  Percent of A/C units that are variable output or multi-stage HVAC system  Are furnaces and boilers modulating?  Maximum energy required to drive all air handlers and fans10  Minimum airflow average. In conditioned space, when the HVAC system is moving air, what is the minimum amount of air it can move in a typical room?  Make, model and specifications of compressors, boilers and furnaces.  What percentage of rooms with exterior walls have individual zones?  Submeters installed on compressors, boilers and cooling towers.11 Total Building Energy Demand  Submeters installed for each floor?12  Monitors installed capable of user feedback of energy consumption per room?13 Lighting  Percent of ceiling fixtures controlled by occupancy or daylight sensors14  Percent of rooms with individual occupancy sensors  Percent of the lighting fixtures in areas with access to daylight automatically dim when daylight is present. Windows Solar heat gain in one room usually  Accurate solar heat gain calculations. increases energy  Make, model and specifications of the windows consumption many rooms 3 Comments on EERE–2011–BT–NOA–004
  • 4. DOE docket: EERE–2011–BT–NOA–004 Sherwin Comments on DOE Commercial Building Asset Rating Program 1 Innovative Advanced Energy Saving Features might include: Thermoelectric windows, white roofs, solar cooling, energy monitoring systems, feedback devices, humidity monitors, CO2 monitors, user-control of ceiling fixtures, advance building control systems. I would to help develop a starter list. This could include both a predefined list and a freeform “other” field. 2 A Grunfos Alpha is a good example of an adaptive pump that reduces energy consumption by 60 to 80%. Also, see Addicted to Energy pages 49 and footnotes 41 to 44. 3 If a lighting fixture is installed, it will be used. The more lighting fixtures a building has, the more electricity it uses. 4 Alternatively: Total number of incandescent bulbs in permanent fixtures (non-fluorescent, non-LED light fixtures hardwired including halogen fixtures, MR 16s, ceiling cans, etc.) Also, see the next footnote 5 Why not count LEDs, T5s and T8s? This number can be inferred: Once the total number of fixtures is counted, subtract the fixtures that need to be replaced: T12, Edison bases, the other incandescent bases. This is how the many energy pros do it. Look to see how many fixtures are on the ceiling and how many of them are candidates for replacement (T12s and incandescent fixtures). 6 This is a proxy for best-in-class digital ballasts. Buildings with great lighting systems have digital ballasts that adjust to light levels. 7 Audit pros, when they walk through a building, look for spots where they can feel air moving. This is a one of the key telltale attributes of an overactive, inefficient HVAC system. This “candle flicker” test is hard to write into a spec, but, in general, buildings that have large fans and blow air at one speed are much less efficient than buildings with smaller multispeed fans. Total HVAC energy consumption can decline dramatically as air movement is reduced. 8 In some climates and for some building types exterior windows are a predictor of building energy consumption. 9 This is the total ACH including fresh and stale air. This metric usually gives an advantage to displacement air systems. 10 The previous section had “the total horsepower of all air-handling fans” (nameplate). This metric is similar, but different and harder number to come by. This is total kilowatts used by all air handlers when they are on. It is a better measure of efficiency, but it may not be worth the extra effort. It might be worth allowing the nameplate number to be entered as the default and optionally allowing building owners to enter actuals, which would make sense for high efficiency fans. It is possible that simply identifying which motors are variable speed will be predictive enough. That is why the second item on in Total Building Energy Demand is Total Horsepower of all fixed-speed motors. 11 These do not need to be utility submeters. Another way to say this: Is the hardware installed to monitor the energy consumption of the building’s major subsystems. Buildings with these “submeters” use less energy. Also, see next note: 12 Some would argue that the existence of submeters is part of an operational rating. They are not. The installation of submeters not scored in Energy Star or any other operational rating. The installation of submeters is a key attribute (asset) of a building. If the architect specifies submeters, the building will, on average, use less energy. 13 See previous note. 14 These are sensors activated by people or photons. This includes manual timers that require users to turn on with each use (countdown timers) which are a form of occupancy sensors. This does not include time-of-day clocks without occupancy or light level sensors. This does not include building control systems that rely solely on time of day. 4 Comments on EERE–2011–BT–NOA–004