3. NN
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
COVER PAGE
0001
HARBOUR QUEEN
P1
12/02/14
Author
Checker
A000
No. Description Date
SHEET LIST
Sheet Number Sheet Name
A200 SitePlan
A310 PENTHOUSE FLOOR PLAN
A307 LEVEL 4 FLOOR PLAN
A304 AMENITIES FLOOR
A305 AMENITIES FLOOR A
A401 NORHT & SOUTH ELEVATION
A403 EAST ELEVATION
A402 WEST ELEVATION
A309 LEVEL 4 PLAN B
A308 LEVEL 4 PLAN A
A306 AMENITIES FLOOR B
A301 GROUND FLOOR PLAN
A302 GROUND FLOOR PLAN A
A303 GROUND FLOOR PLAN B
A312 PENTHOUSE FLOOR PLAN B
A501 CROSS SECTION
A201 SITE PLAN
A601 WALL SECTIONS
A801 PLAN DETAILS
A802 SECTION DETAILS
A311 PENTHOUSE FLOOR PLAN A
A602 WALL SECTIONS
A000 COVER PAGE
4. A111
2
-
-
-
-
-
BONNYCASTLE
TORONTOSHORELINE
LAKEFRONT
SQUARE
QUEENSQUAYST.
SHERBOURNE COMMON
PROPOSED 9 STOREY
BUILDING
1404
61050
1404
6000
6000
1404
30003000
9000
9000
7854
12671
61050
OVRHANG @ 5m FROM
THE GRADE
4098
9671
7000
PROPOSED FLOWER
BED
PROPOSED
PLANING
22925
78850
1671
11068 6932
3172
3172
13913596
3000
4475
4479
4260
1404
1404
3000
596
596
596
3071
7000
12671
PROPOSED PLANTING
139900
37000
5000
PROPERTY LINE
SETBACK
PROPERTY LINE
PROPERTYLINE
19000
NN
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
1 : 300
SITE PLAN
0001
Harbor Queen
P1
12/02/14
Author
Checker
A201
1 : 300A201
SITE & ROOF PLAN1
NOTES:
1) CURB HEIGHT IS 150MM ABOV ASHPALT.
2) LIGHTS ILLUMINATING PARKING LOT SHALL NOT DISPERSE LIGHT
BEYOND PROPEY LINES, AND WILL HAVE CUT-OFFS.
No. Description Date
1 Revision 1 Date 1
5. UP
UPUP
D D
C C
B B
H
H
J J
K K
E E
F F
G G
A A
2
2
1
1
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
6000 6000 6000 6000 5695 6305 6000 6000 6000 6000 6000 6000 6000
78000
1600342225783538862513834221514
22075
1
A302
1
A303
54 m²
RETAIL SPACE
54 m²
RETAIL SPACE
54 m²
RETAIL SPACE
143 m²
RETAIL SPACE 21 m²
MAIL ROOM
21 m²
MANAG.
OFFICE
121 m²
LOADING BAY
Not Enclosed
RETAIL SPACE
23 m²
RETAIL
STORAGE
19 m²
LOADING
AREA
11 m²
GARBG.
ROOM
9 m²
RECYC.
(RES)
14 m²
SERVC.
ELV.
LOAD.
35 m²
SECURED ENTRANCE
51 m²
SERVICE AREA
113 m²
BYCICLE STORAGE147 m²
RETAIL SPACE
54 m²
RETAIL SPACE
FIRE RATED WALLS
BASIC MATERIALS TYPE % SOLID FIRE RATING ADDED MATERIALS STC FINAL FIRE
RATING
W1
W2
W4
W5
POURED CONCRETE
150 mm MIN.
140 CONCRETE BLOCK
WITH PRECAST PANEL
140mm CONCRETE
BLOCK
W6
123mm METAL STUD
WALL
W7
SHAFT ENCLOSURE
SHAFT ENCLOSURE
N
N
N
N
N
ULC W 407
OR
ULS W 415
2 LAYER 12.7 TYPW X GYPSUM
WALLBOARD BOTH SIDES
38mm SOUND BLANKETS (BY C.G.C)
55+ 2 HRS.
100%
STD
ULC W 507
U OF C 2-
8-72
4.0 HRS.
12.7mm DRYWALL LAMINATED TO
BLOCK IN FINISHED AREAS
NOTES:
N = NORMAL WEIGHT
L = LIGHT WIRGHT
STC = SOUND TRANSMISSION CLASS
USE "WONDER BOARD" OR EQUAL AT ALL SHOWER AND TUB LOCATION
ALL MECHANICALLY FASTENED GYPSUM WALLBOARDS TO BE IN ACCORDANCE WITH
CSA. A82.31-2012 "GYPSUM WALLBOARD APPLICATION"
ABBREVIATIONS:
AD. AREA DRAIN
C.J. CONTROL JOINT
E.J. EXPANSION JOINT
E.P. ELECTRICAL PANEL
F.F.E. FINISH FLOOR ELEVATION
F.H.C. FIRE HOSE CABINET
L.W. LOW WALL
P.S PIPE SPACE
RD. ROOF DRAIN
S.P. SECURITY PANEL
T.O.C. TOOP OF CURB
T.O.W. TOP OF WALL
U.P. UNIT PANEL
W.I.C. WALK-IN CLOSET
PRECAST PANELS
ALL DESIGN, MANUFACTURE AND INSTALLATION TO CONFORM TO N.B.C. AND C.S.A. 3 – A23. 4-94. LATEST
EDITION
PRECAST SUPPLIES IS RESPONSIBLE FOR DESIGN OF ALL PRECAST PANELS AND THEIR CONNECTIONS. THESE
CONNECTIONS TO INCLUDE THE REQUIRED INSERTS. ANCHORS AND BRACES TO BE EMBEDDED IN, OR
CONNECTED TO THE BUILDING STRUCTURE.
ALL PRECAST CONCRETE DESIGN AND SHOP DRAWINGS TO BE SUBMITTED FOR REVIEW. CARRYING THE STAMP OF
A REGISTERED PROFESSIONAL ENGINEER.
ALL CONNECTION TO BE DESIGNED IN SUCH A MANNER AS NOT TO CAUSE LOCAL OVERSTRESSING OF THE
SURROUNDING CONCRETE OR STRUCTURAL STEEL AND TO BE WHOLLY SUFFICIENT BY THEMSELVES, WITHOUT ANY
FURTHER REINFORCING, UNLESS SO STATED BY THE MANUFACTURER.
123 mm INTERIOR PARTITION
STEEL STUD WALL 1-HRS. RATING
150 mm POUR CONCRETE
PRECAST PANEL WALL
CONCRETE BLOCK WITH PRECAST PANEL
W2
W1
W3
W4
W5
W6
CONCRETE WALL WITH GYPSUM ON
INTERIOR
150mm POUR CONCRETE
ELEVATOR SHAFT
150mm POUR CONCRETEW7
WALL SCHEDULE
WALL TYPEWALL # ILUSTRATION
DBL LAYER OF 12.7mm GYPSUM WALL BOARD
150mm MIN POURED CONCRETE
DBL LAYER 12.7mm SYPSUM WALLBOARD
12.7mm GYPSUM BOARD
METAL STUD @ 600mm o/c
12.7mm SYPSUM BOARD
115mm PRECAST CONC. PANEL
50mm RIGID INSL.
92mm METAL STUD @ 600o/c WITH 89mm BATT INSL.
12.7mm GYSPUM WALBOARD
115mm PRECAST CONC. PANEL
50mm RIGID INSL.
140mm CONC. BLOCK
92mm STEEL STUD @600o/c WITH 89mm BATT INSL
12.7mm GYPSUM WALLBOARD
150mm MIN. POURED CONCRETE
92mm STEEL STUD @ 600mm o/c
89mm BATT INSL.
12.7mm GYPSUM WALLBOARD GLUED
150mm MIN. POURED CONCRETE
12.7mm GYPSUM WALLBOARD GLUED
150mm MIN POURED CONCRETE
NN
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
As indicated
GROUND FLOOR
PLAN
0001
HARBOUR QUEEN
P1
12/02/14
Author
Checker
A301
1 : 200A301
GROUND FLOOR LEVEL1
No. Description Date
6. UP
UP
D D
C C
B B
H H
J J
K K
E E
F
F
G
G
A A
1
A501
2
2
1
1
3
3
4
4
5
5
6
6
7
7
8
8
143 m²
RETAIL SPACE
54 m²
RETAIL SPACE
74 m²
SERVICE CORRIDOR
147 m²
RETAIL SPACE
54 m²
RETAIL SPACE
54 m²
RETAIL SPACE
15 m²
JANITORS
ROOM
35 m²
SECURED ENTRANCE
21 m²
MAIL ROOM
21 m²
MANAG.
OFFICE
54 m²
RETAIL SPACE
120 m²
MAIN LOBBY
12 m²
MALE WASHROOM
19 m²
FEMALE WASHROOM
W1
W1 W1 W1
W1
W1
W1
W1
W1
W6
W1
W1
W1
W1
W3 W1
W3
W3
4535 915 6349
3650
5962
174823712236
2200
1625
1499
750
750
21801587
1641625
2125
D-02
D-02
6000
6000 5800 200 58005900 2005860
5760 200 5800 200 1275 200 4425 6000 5900 200 1912
335
1263 2625 1263
275 275
1288 2675 1288
275 275
1238 1313 1238 723 1291 2682 1291 6275
3420
1002 5675 1600 1425
236
9938
1298 1325 1375 502 2022 3156
4300 200 5178
7865
1912 200
13372004950
9678
12883
3789 5890
OPEN TO ABOVE
750
2123
439813757
1885
W2
2123
750
439813726
750
2123
813726439
750
2123
439813726
2123
439813746
750
W2
W2W2W2
D-02
D-02
D-02
D-02
D-02
D-02
D-02
D-02
D-01 D-01
D-01D-01D-01
D-02
D-01D-01
R @27
185.2 mm
R @26
192.3 mm
700
FIRE RATED WALLS
BASIC MATERIALS TYPE % SOLID FIRE RATING ADDED MATERIALS STC FINAL FIRE
RATING
W1
W2
W4
W5
POURED CONCRETE
150 mm MIN.
140 CONCRETE BLOCK
WITH PRECAST PANEL
140mm CONCRETE
BLOCK
W6
123mm METAL STUD
WALL
W7
SHAFT ENCLOSURE
SHAFT ENCLOSURE
N
N
N
N
N
ULC W 407
OR
ULS W 415
2 LAYER 12.7 TYPW X GYPSUM
WALLBOARD BOTH SIDES
38mm SOUND BLANKETS (BY C.G.C)
55+ 2 HRS.
100%
STD
ULC W 507
U OF C 2-
8-72
4.0 HRS.
12.7mm DRYWALL LAMINATED TO
BLOCK IN FINISHED AREAS
NOTES:
N = NORMAL WEIGHT
L = LIGHT WIRGHT
STC = SOUND TRANSMISSION CLASS
USE "WONDER BOARD" OR EQUAL AT ALL SHOWER AND TUB LOCATION
ALL MECHANICALLY FASTENED GYPSUM WALLBOARDS TO BE IN ACCORDANCE WITH
CSA. A82.31-2012 "GYPSUM WALLBOARD APPLICATION"
ABBREVIATIONS:
AD. AREA DRAIN
C.J. CONTROL JOINT
E.J. EXPANSION JOINT
E.P. ELECTRICAL PANEL
F.F.E. FINISH FLOOR ELEVATION
F.H.C. FIRE HOSE CABINET
L.W. LOW WALL
P.S PIPE SPACE
RD. ROOF DRAIN
S.P. SECURITY PANEL
T.O.C. TOOP OF CURB
T.O.W. TOP OF WALL
U.P. UNIT PANEL
W.I.C. WALK-IN CLOSET
PRECAST PANELS
ALL DESIGN, MANUFACTURE AND INSTALLATION TO CONFORM TO N.B.C. AND C.S.A. 3 – A23. 4-94. LATEST
EDITION
PRECAST SUPPLIES IS RESPONSIBLE FOR DESIGN OF ALL PRECAST PANELS AND THEIR CONNECTIONS. THESE
CONNECTIONS TO INCLUDE THE REQUIRED INSERTS. ANCHORS AND BRACES TO BE EMBEDDED IN, OR
CONNECTED TO THE BUILDING STRUCTURE.
ALL PRECAST CONCRETE DESIGN AND SHOP DRAWINGS TO BE SUBMITTED FOR REVIEW. CARRYING THE STAMP OF
A REGISTERED PROFESSIONAL ENGINEER.
ALL CONNECTION TO BE DESIGNED IN SUCH A MANNER AS NOT TO CAUSE LOCAL OVERSTRESSING OF THE
SURROUNDING CONCRETE OR STRUCTURAL STEEL AND TO BE WHOLLY SUFFICIENT BY THEMSELVES, WITHOUT ANY
FURTHER REINFORCING, UNLESS SO STATED BY THE MANUFACTURER.
123 mm INTERIOR PARTITION
STEEL STUD WALL 1-HRS. RATING
150 mm POUR CONCRETE
PRECAST PANEL WALL
CONCRETE BLOCK WITH PRECAST PANEL
W2
W1
W3
W4
W5
W6
CONCRETE WALL WITH GYPSUM ON
INTERIOR
150mm POUR CONCRETE
ELEVATOR SHAFT
150mm POUR CONCRETEW7
WALL LEGEND
WALL TYPEWALL # ILUSTRATION
NN
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
1 : 100
GROUND FLOOR
PLAN A
0001
HARBOUR QUEEN
P1
12/02/14
Author
Checker
A302
1 : 100A302
GROUND FLOOR LEVEL A1
No. Description Date
7. UP
D D
C C
B B
H H
J J
K K
E E
F F
I I
G G
A A
1
A501
8
8
9
9
10
10
11
11
12
12
13
13
14
14
-
---
W1
W3
W4
W5
W5
W6
W1
W1
W1
W2
W6
W2
W3 W4
W6
W6
W6
W1
W1
W3
A. S.
113 m²
BYCICLE STORAGE
Not Enclosed
RETAIL SPACE
121 m²
LOADING BAY
19 m²
LOADING
AREA
51 m²
SERVICE AREA
11 m²
GARBG.
ROOM
9 m²
RECYC.
(RES)
14 m²
SERVC.
ELV.
LOAD.
11 m²
GARBAGE/RACYCLING
(RETAIL)
23 m²
RETAIL
STORAGE
D-02
D-02
D-02
D-02 D-02
D-04 D-05
D-05
D-02
D-02
D-02
D-06
D-07
D-07
135091525653035
1840
530 1730 2051 915
98
2544 123 2534 200 3725
3457
6142
915
137
900 4000 7099
221657095445
1144
W2
2587 123
1550
10033 915 976
1419
1865
5057
3597
5900 6000 6000 5860
13743422600035382097
D-05
7391
949
3458
5362
5792 1730 5368 1175
350 11150 260
8624281614832841
317350
5900
6000 6000 6000 6000 6000 6000
36000
45011503422257835388625138342215141163
22075
1135 1320 2031
7 m²
ELEVATOR
# 1
6 m²
ELEVATOR
# 2
6 m²
ELEVATOR
# 3
800
1500 2080 1500 1597
1602
R @26
192.3 mm
FIRE RATED WALLS
BASIC MATERIALS TYPE % SOLID FIRE RATING ADDED MATERIALS STC FINAL FIRE
RATING
W1
W2
W4
W5
POURED CONCRETE
150 mm MIN.
140 CONCRETE BLOCK
WITH PRECAST PANEL
140mm CONCRETE
BLOCK
W6
123mm METAL STUD
WALL
W7
SHAFT ENCLOSURE
SHAFT ENCLOSURE
N
N
N
N
N
ULC W 407
OR
ULS W 415
2 LAYER 12.7 TYPW X GYPSUM
WALLBOARD BOTH SIDES
38mm SOUND BLANKETS (BY C.G.C)
55+ 2 HRS.
100%
STD
ULC W 507
U OF C 2-
8-72
4.0 HRS.
12.7mm DRYWALL LAMINATED TO
BLOCK IN FINISHED AREAS
NOTES:
N = NORMAL WEIGHT
L = LIGHT WIRGHT
STC = SOUND TRANSMISSION CLASS
USE "WONDER BOARD" OR EQUAL AT ALL SHOWER AND TUB LOCATION
ALL MECHANICALLY FASTENED GYPSUM WALLBOARDS TO BE IN ACCORDANCE WITH
CSA. A82.31-2012 "GYPSUM WALLBOARD APPLICATION"
ABBREVIATIONS:
AD. AREA DRAIN
C.J. CONTROL JOINT
E.J. EXPANSION JOINT
E.P. ELECTRICAL PANEL
F.F.E. FINISH FLOOR ELEVATION
F.H.C. FIRE HOSE CABINET
L.W. LOW WALL
P.S PIPE SPACE
RD. ROOF DRAIN
S.P. SECURITY PANEL
T.O.C. TOOP OF CURB
T.O.W. TOP OF WALL
U.P. UNIT PANEL
W.I.C. WALK-IN CLOSET
PRECAST PANELS
ALL DESIGN, MANUFACTURE AND INSTALLATION TO CONFORM TO N.B.C. AND C.S.A. 3 – A23. 4-94. LATEST
EDITION
PRECAST SUPPLIES IS RESPONSIBLE FOR DESIGN OF ALL PRECAST PANELS AND THEIR CONNECTIONS. THESE
CONNECTIONS TO INCLUDE THE REQUIRED INSERTS. ANCHORS AND BRACES TO BE EMBEDDED IN, OR
CONNECTED TO THE BUILDING STRUCTURE.
ALL PRECAST CONCRETE DESIGN AND SHOP DRAWINGS TO BE SUBMITTED FOR REVIEW. CARRYING THE STAMP OF
A REGISTERED PROFESSIONAL ENGINEER.
ALL CONNECTION TO BE DESIGNED IN SUCH A MANNER AS NOT TO CAUSE LOCAL OVERSTRESSING OF THE
SURROUNDING CONCRETE OR STRUCTURAL STEEL AND TO BE WHOLLY SUFFICIENT BY THEMSELVES, WITHOUT ANY
FURTHER REINFORCING, UNLESS SO STATED BY THE MANUFACTURER.
123 mm INTERIOR PARTITION
STEEL STUD WALL 1-HRS. RATING
150 mm POUR CONCRETE
PRECAST PANEL WALL
CONCRETE BLOCK WITH PRECAST PANEL
W2
W1
W3
W4
W5
W6
CONCRETE WALL WITH GYPSUM ON
INTERIOR
150mm POUR CONCRETE
ELEVATOR SHAFT
150mm POUR CONCRETEW7
WALL LEGEND
WALL TYPEWALL # ILUSTRATION
NN
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
1 : 100
GROUND FLOOR
PLAN B
0001
HARBOUR QUEEN
P1
12/02/14
Author
Checker
A303
1 : 100A303
GROUND FLOOR LEVEL B1
No. Description Date
8. DN
DN
UP
DN
UP
D D
C
C
B
B
H H
J J
K K
E
E
F
F
I I
G G
A
A
2
2
1
1
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
11790
6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000
78000
45011503422257835388625138342215141163
22075
1
A305
1
A306
FIRE RATED WALLS
BASIC MATERIALS TYPE % SOLID FIRE RATING ADDED MATERIALS STC FINAL FIRE
RATING
W1
W2
W4
W5
POURED CONCRETE
150 mm MIN.
140 CONCRETE BLOCK
WITH PRECAST PANEL
140mm CONCRETE
BLOCK
W6
123mm METAL STUD
WALL
W7
SHAFT ENCLOSURE
SHAFT ENCLOSURE
N
N
N
N
N
ULC W 407
OR
ULS W 415
2 LAYER 12.7 TYPW X GYPSUM
WALLBOARD BOTH SIDES
38mm SOUND BLANKETS (BY C.G.C)
55+ 2 HRS.
100%
STD
ULC W 507
U OF C 2-
8-72
4.0 HRS.
12.7mm DRYWALL LAMINATED TO
BLOCK IN FINISHED AREAS
NOTES:
N = NORMAL WEIGHT
L = LIGHT WIRGHT
STC = SOUND TRANSMISSION CLASS
USE "WONDER BOARD" OR EQUAL AT ALL SHOWER AND TUB LOCATION
ALL MECHANICALLY FASTENED GYPSUM WALLBOARDS TO BE IN ACCORDANCE WITH
CSA. A82.31-2012 "GYPSUM WALLBOARD APPLICATION"
ABBREVIATIONS:
AD. AREA DRAIN
C.J. CONTROL JOINT
E.J. EXPANSION JOINT
E.P. ELECTRICAL PANEL
F.F.E. FINISH FLOOR ELEVATION
F.H.C. FIRE HOSE CABINET
L.W. LOW WALL
P.S PIPE SPACE
RD. ROOF DRAIN
S.P. SECURITY PANEL
T.O.C. TOOP OF CURB
T.O.W. TOP OF WALL
U.P. UNIT PANEL
W.I.C. WALK-IN CLOSET
PRECAST PANELS
ALL DESIGN, MANUFACTURE AND INSTALLATION TO CONFORM TO N.B.C. AND C.S.A. 3 – A23. 4-94. LATEST
EDITION
PRECAST SUPPLIES IS RESPONSIBLE FOR DESIGN OF ALL PRECAST PANELS AND THEIR CONNECTIONS. THESE
CONNECTIONS TO INCLUDE THE REQUIRED INSERTS. ANCHORS AND BRACES TO BE EMBEDDED IN, OR
CONNECTED TO THE BUILDING STRUCTURE.
ALL PRECAST CONCRETE DESIGN AND SHOP DRAWINGS TO BE SUBMITTED FOR REVIEW. CARRYING THE STAMP OF
A REGISTERED PROFESSIONAL ENGINEER.
ALL CONNECTION TO BE DESIGNED IN SUCH A MANNER AS NOT TO CAUSE LOCAL OVERSTRESSING OF THE
SURROUNDING CONCRETE OR STRUCTURAL STEEL AND TO BE WHOLLY SUFFICIENT BY THEMSELVES, WITHOUT ANY
FURTHER REINFORCING, UNLESS SO STATED BY THE MANUFACTURER.
123 mm INTERIOR PARTITION
STEEL STUD WALL 1-HRS. RATING
150 mm POUR CONCRETE
PRECAST PANEL WALL
CONCRETE BLOCK WITH PRECAST PANEL
W2
W1
W3
W4
W5
W6
CONCRETE WALL WITH GYPSUM ON
INTERIOR
150mm POUR CONCRETE
ELEVATOR SHAFT
150mm POUR CONCRETEW7
WALL LEGEND
WALL TYPEWALL # ILUSTRATION
NN
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
As indicated
AMENITIES FLOOR
0001
HARBOUR QUEEN
P1
12/02/14
Author
Checker
A304
1 : 200A304
LEVEL 2 AMENITIES1
No. Description Date
9. UP
D D
C C
B B
H H
J J
K K
E E
F F
I I
G G
A A
2
2
1
1
3
3
4
4
5
5
6
6
7
7
8
8
6000 6000 6000 6000 6000
22075
17925
87 915 11411 813
864 696 5204 398
2680
6150 5850
23785 200 1641
1011515015002570659
3566 12522
4607
6000
58501693 150
10005
1350
11631514342251384400257834221150450
22075
222 m²
GYM
194 m²
SWIMMING POOL
22 m²
MALE
CHANGE ROOM
49 m²
CORRIDOR
58 m²
YOGA STUDIO
W3
W1
W1
W1
W1
W1
W2
W1
W2
-
---
-
---
-
---
79 m²
PARTY ROOM
RECEPTION/LOUNGE
17 m²
MALE
CHANGEROOM
14 m²
FEMALE
CHANGEROOM
19 m²
FEMALE
CHANGEROOM
OPEN TO BELOW
2068
176134221460
5219
6000 6000
R @26
192.3 mm
700
FIRE RATED WALLS
BASIC MATERIALS TYPE % SOLID FIRE RATING ADDED MATERIALS STC FINAL FIRE
RATING
W1
W2
W4
W5
POURED CONCRETE
150 mm MIN.
140 CONCRETE BLOCK
WITH PRECAST PANEL
140mm CONCRETE
BLOCK
W6
123mm METAL STUD
WALL
W7
SHAFT ENCLOSURE
SHAFT ENCLOSURE
N
N
N
N
N
ULC W 407
OR
ULS W 415
2 LAYER 12.7 TYPW X GYPSUM
WALLBOARD BOTH SIDES
38mm SOUND BLANKETS (BY C.G.C)
55+ 2 HRS.
100%
STD
ULC W 507
U OF C 2-
8-72
4.0 HRS.
12.7mm DRYWALL LAMINATED TO
BLOCK IN FINISHED AREAS
NOTES:
N = NORMAL WEIGHT
L = LIGHT WIRGHT
STC = SOUND TRANSMISSION CLASS
USE "WONDER BOARD" OR EQUAL AT ALL SHOWER AND TUB LOCATION
ALL MECHANICALLY FASTENED GYPSUM WALLBOARDS TO BE IN ACCORDANCE WITH
CSA. A82.31-2012 "GYPSUM WALLBOARD APPLICATION"
ABBREVIATIONS:
AD. AREA DRAIN
C.J. CONTROL JOINT
E.J. EXPANSION JOINT
E.P. ELECTRICAL PANEL
F.F.E. FINISH FLOOR ELEVATION
F.H.C. FIRE HOSE CABINET
L.W. LOW WALL
P.S PIPE SPACE
RD. ROOF DRAIN
S.P. SECURITY PANEL
T.O.C. TOOP OF CURB
T.O.W. TOP OF WALL
U.P. UNIT PANEL
W.I.C. WALK-IN CLOSET
PRECAST PANELS
ALL DESIGN, MANUFACTURE AND INSTALLATION TO CONFORM TO N.B.C. AND C.S.A. 3 – A23. 4-94. LATEST
EDITION
PRECAST SUPPLIES IS RESPONSIBLE FOR DESIGN OF ALL PRECAST PANELS AND THEIR CONNECTIONS. THESE
CONNECTIONS TO INCLUDE THE REQUIRED INSERTS. ANCHORS AND BRACES TO BE EMBEDDED IN, OR
CONNECTED TO THE BUILDING STRUCTURE.
ALL PRECAST CONCRETE DESIGN AND SHOP DRAWINGS TO BE SUBMITTED FOR REVIEW. CARRYING THE STAMP OF
A REGISTERED PROFESSIONAL ENGINEER.
ALL CONNECTION TO BE DESIGNED IN SUCH A MANNER AS NOT TO CAUSE LOCAL OVERSTRESSING OF THE
SURROUNDING CONCRETE OR STRUCTURAL STEEL AND TO BE WHOLLY SUFFICIENT BY THEMSELVES, WITHOUT ANY
FURTHER REINFORCING, UNLESS SO STATED BY THE MANUFACTURER.
123 mm INTERIOR PARTITION
STEEL STUD WALL 1-HRS. RATING
150 mm POUR CONCRETE
PRECAST PANEL WALL
CONCRETE BLOCK WITH PRECAST PANEL
W2
W1
W3
W4
W5
W6
CONCRETE WALL WITH GYPSUM ON
INTERIOR
150mm POUR CONCRETE
ELEVATOR SHAFT
150mm POUR CONCRETEW7
WALL LEGEND
WALL TYPEWALL # ILUSTRATION
NN
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
1 : 100
AMENITIES FLOOR
A
0001
HARBOUR QUEEN
P1
12/02/14
Author
Checker
A305
1 : 100A305
LEVEL 2 AMENITIES A1
No. Description Date
10. UP
D D
C C
B B
H H
J J
K K
E E
F F
I I
G G
A A
L L
8
8
9
9
10
10
11
11
12
12
13
13
14
14
335
1473 4000 8277
10005
6000
1600
3010
1600
52411137
963 1321 2002
3798 4000 4302
335 5127 796 5204 398
5936 6000
15013221501322
1410
W1
-
---
-
---
-
---
R @26
192.3 mm
700
FIRE RATED WALLS
BASIC MATERIALS TYPE % SOLID FIRE RATING ADDED MATERIALS STC FINAL FIRE
RATING
W1
W2
W4
W5
POURED CONCRETE
150 mm MIN.
140 CONCRETE BLOCK
WITH PRECAST PANEL
140mm CONCRETE
BLOCK
W6
123mm METAL STUD
WALL
W7
SHAFT ENCLOSURE
SHAFT ENCLOSURE
N
N
N
N
N
ULC W 407
OR
ULS W 415
2 LAYER 12.7 TYPW X GYPSUM
WALLBOARD BOTH SIDES
38mm SOUND BLANKETS (BY C.G.C)
55+ 2 HRS.
100%
STD
ULC W 507
U OF C 2-
8-72
4.0 HRS.
12.7mm DRYWALL LAMINATED TO
BLOCK IN FINISHED AREAS
NOTES:
N = NORMAL WEIGHT
L = LIGHT WIRGHT
STC = SOUND TRANSMISSION CLASS
USE "WONDER BOARD" OR EQUAL AT ALL SHOWER AND TUB LOCATION
ALL MECHANICALLY FASTENED GYPSUM WALLBOARDS TO BE IN ACCORDANCE WITH
CSA. A82.31-2012 "GYPSUM WALLBOARD APPLICATION"
ABBREVIATIONS:
AD. AREA DRAIN
C.J. CONTROL JOINT
E.J. EXPANSION JOINT
E.P. ELECTRICAL PANEL
F.F.E. FINISH FLOOR ELEVATION
F.H.C. FIRE HOSE CABINET
L.W. LOW WALL
P.S PIPE SPACE
RD. ROOF DRAIN
S.P. SECURITY PANEL
T.O.C. TOOP OF CURB
T.O.W. TOP OF WALL
U.P. UNIT PANEL
W.I.C. WALK-IN CLOSET
PRECAST PANELS
ALL DESIGN, MANUFACTURE AND INSTALLATION TO CONFORM TO N.B.C. AND C.S.A. 3 – A23. 4-94. LATEST
EDITION
PRECAST SUPPLIES IS RESPONSIBLE FOR DESIGN OF ALL PRECAST PANELS AND THEIR CONNECTIONS. THESE
CONNECTIONS TO INCLUDE THE REQUIRED INSERTS. ANCHORS AND BRACES TO BE EMBEDDED IN, OR
CONNECTED TO THE BUILDING STRUCTURE.
ALL PRECAST CONCRETE DESIGN AND SHOP DRAWINGS TO BE SUBMITTED FOR REVIEW. CARRYING THE STAMP OF
A REGISTERED PROFESSIONAL ENGINEER.
ALL CONNECTION TO BE DESIGNED IN SUCH A MANNER AS NOT TO CAUSE LOCAL OVERSTRESSING OF THE
SURROUNDING CONCRETE OR STRUCTURAL STEEL AND TO BE WHOLLY SUFFICIENT BY THEMSELVES, WITHOUT ANY
FURTHER REINFORCING, UNLESS SO STATED BY THE MANUFACTURER.
123 mm INTERIOR PARTITION
STEEL STUD WALL 1-HRS. RATING
150 mm POUR CONCRETE
PRECAST PANEL WALL
CONCRETE BLOCK WITH PRECAST PANEL
W2
W1
W3
W4
W5
W6
CONCRETE WALL WITH GYPSUM ON
INTERIOR
150mm POUR CONCRETE
ELEVATOR SHAFT
150mm POUR CONCRETEW7
WALL LEGEND
WALL TYPEWALL # ILUSTRATION
NN
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
1 : 100
AMENITIES FLOOR
B
0001
HARBOUR QUEEN
P1
12/02/14
Author
Checker
A306
1 : 100A306
LEVEL 2 AMENITIES B1
No. Description Date
11. DN
UPUP
MECH
D D
C C
H H
J J
K K
E E
F F
G G
A A
2
2
1
1
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000
78000
342225783538862513834221514
22075
1
A308
2
A309
FIRE RATED WALLS
BASIC MATERIALS TYPE % SOLID FIRE RATING ADDED MATERIALS STC FINAL FIRE
RATING
W1
W2
W4
W5
POURED CONCRETE
150 mm MIN.
140 CONCRETE BLOCK
WITH PRECAST PANEL
140mm CONCRETE
BLOCK
W6
123mm METAL STUD
WALL
W7
SHAFT ENCLOSURE
SHAFT ENCLOSURE
N
N
N
N
N
ULC W 407
OR
ULS W 415
2 LAYER 12.7 TYPW X GYPSUM
WALLBOARD BOTH SIDES
38mm SOUND BLANKETS (BY C.G.C)
55+ 2 HRS.
100%
STD
ULC W 507
U OF C 2-
8-72
4.0 HRS.
12.7mm DRYWALL LAMINATED TO
BLOCK IN FINISHED AREAS
NOTES:
N = NORMAL WEIGHT
L = LIGHT WIRGHT
STC = SOUND TRANSMISSION CLASS
USE "WONDER BOARD" OR EQUAL AT ALL SHOWER AND TUB LOCATION
ALL MECHANICALLY FASTENED GYPSUM WALLBOARDS TO BE IN ACCORDANCE WITH
CSA. A82.31-2012 "GYPSUM WALLBOARD APPLICATION"
ABBREVIATIONS:
AD. AREA DRAIN
C.J. CONTROL JOINT
E.J. EXPANSION JOINT
E.P. ELECTRICAL PANEL
F.F.E. FINISH FLOOR ELEVATION
F.H.C. FIRE HOSE CABINET
L.W. LOW WALL
P.S PIPE SPACE
RD. ROOF DRAIN
S.P. SECURITY PANEL
T.O.C. TOOP OF CURB
T.O.W. TOP OF WALL
U.P. UNIT PANEL
W.I.C. WALK-IN CLOSET
PRECAST PANELS
ALL DESIGN, MANUFACTURE AND INSTALLATION TO CONFORM TO N.B.C. AND C.S.A. 3 – A23. 4-94. LATEST
EDITION
PRECAST SUPPLIES IS RESPONSIBLE FOR DESIGN OF ALL PRECAST PANELS AND THEIR CONNECTIONS. THESE
CONNECTIONS TO INCLUDE THE REQUIRED INSERTS. ANCHORS AND BRACES TO BE EMBEDDED IN, OR
CONNECTED TO THE BUILDING STRUCTURE.
ALL PRECAST CONCRETE DESIGN AND SHOP DRAWINGS TO BE SUBMITTED FOR REVIEW. CARRYING THE STAMP OF
A REGISTERED PROFESSIONAL ENGINEER.
ALL CONNECTION TO BE DESIGNED IN SUCH A MANNER AS NOT TO CAUSE LOCAL OVERSTRESSING OF THE
SURROUNDING CONCRETE OR STRUCTURAL STEEL AND TO BE WHOLLY SUFFICIENT BY THEMSELVES, WITHOUT ANY
FURTHER REINFORCING, UNLESS SO STATED BY THE MANUFACTURER.
123 mm INTERIOR PARTITION
STEEL STUD WALL 1-HRS. RATING
150 mm POUR CONCRETE
PRECAST PANEL WALL
CONCRETE BLOCK WITH PRECAST PANEL
W2
W1
W3
W4
W5
W6
CONCRETE WALL WITH GYPSUM ON
INTERIOR
150mm POUR CONCRETE
ELEVATOR SHAFT
150mm POUR CONCRETEW7
WALL LEGEND
WALL TYPEWALL # ILUSTRATION
NN
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
As indicated
LEVEL 4 FLOOR
PLAN
0001
HARBOUR QUEEN
P1
12/02/14
Author
Checker
A307
1 : 200A307
Level 4 WD Floor Plan1
No. Description Date
12. UP
D
D
C
C
B B
H H
J
J
K
K
E E
F F
I I
G G
A A
1
A501
2
2
1
1
3
3
4
4
5
5
6
6
7
7
8
8
43 m²
LIVING ROOM
12 m²
FAMILY ROOM
6 m²
BATHROOM
9 m²
LAUNDRY
8 m²
BATH.
21 m²
MASTER BED.
22 m²
KITCHEN
21 m²
DINING ROOM
14 m²
FOYER
7 m²
BALCONY
5 m²
POWD.
10 m²
KITCHEN
5 m²
LAUNDRY
5 m²
BATH
7 m²
FOYER
5 m²
WIC
8 m²
HALLW.
4 m²
BATH
12 m²
DEN
4 m²
POWD.
6 m²
LAUNDRY
8 m²
KITCHEN
100100
6000 6000 6000 6000 6000 6000 6000
22075
18 m²
BEDROOM
19 m²
BALCONY
16 m²
BALCONY
2 m²
MECH
19 m²
1 BEDROOM
21 m²
BALCONY
11 m²
BEDROOM
5 m²
WIC
7 m²
BATHROOM
6 m²
WIC
7 m²
KITCHEN
19 m²
LIVING ROOM
5 m²
BATHROOM
9 m²
BEDROOM
2 m²
FOYER
9 m²
KITCHEN
18 m²
LIVING ROOM
9 m²
KITCHEN
2 m²
FOYER
3 m²
DINING
14 m²
LIVING ROOM
13 m²
BEDROOM
5 m²
BATH.
14 m²
DEN
8 m²
MASTER
BATH.
17 m²
1 BEDROOM
15 m²
KITCHEN & DINING
28 m²
LIVING ROOM
3 m²
PWDR.
2 m²
FOYER
49 m²
CORRIDOR
8 m²
BALCONY
Unit 308
624
45011503422257844005138342215141163
22075
42000
6000 6000 6000 6000 6000 6000 6000
42000
4148
5725
18131208
1813
1989
951
1489
56591515089153125915227527449151030
1787
1815762
4014
1725 937
3978845
1000
18321876
1136
15242473
2564
762
1869
2539
7498
5760
6513
5070
18651650
1689
1477
913508
1539 2212
3159
3462
927 2289
3339
2250
13002187
2697
5800
3084
4282
6089
1395
1175 2852 911
5800
1785
2866
1625
3536
3819
2542
1507
1237
1191
1027
2902
2866
2431
972
874
821
2975
3330
2677
19238131200
2013
2431
1203 1105
2431
2197
4461
4977 848
943
2747
1559
2950
2334
2338
2157
2023915
2822
29012660
2822
2215
600
2664 999 948
152310261487
2689 1946
3048
2589 1775
19061750
1564
701
1012
848
5800
21 m²
BED. LIV
ROOM
1222 1105
2451
2451
2013972
2451
848
757
2994
4001
2683
1189
2038
4461
18737621329
3 m²
DINING
15 m²
LIVING
ROOM
9 m²
KIT.
2 m²
FOYR.
9 m²
BEDROOM
5 m²
BATH.
2431
20139723267
787
874
18768131303
2431
1203 1105
761
849
27 m²
BEDROOM
2246 1300 2254
858
849
568 1442 910 913
5805
20502446
1100 996 1576
1705
2572
5805
2010
1062
923
1849
800
5803
5423915
1705
2123
3003
2131
712
9001048
2050
W2
W2
W2
W2
W2
W2
W1
W2
W3
W1 W2
W1
W2
W2
W2
W2
W1
W1
W2
W2
W1
W1
W2
W1
W2
W1
W2
W2
W1
W1
W2
W1
W1
W2
W2
W2
W2
W1
W2
W1
W2
W2 W1
W1
W1
W2
W2
W1
W1 W1
W2W1
W2
W3
W1
W2
W1
W2
W2
W1
W1
W1
W2
W2
W1
W2
W1W2
D-01
D-01
D-08
D-08
D-01
D-01
D-09 D-09
D-01
D-01
D-08
D-08
D-01
D-08
D-01
D-09
D-01
D-01
D-01
D-08
D-09
D-01
D-09
D-09
D-10
D-10
D-10
D-09
D-08
D-01
D-01
D-01
D-01
D-08
D-01
D-01
D-08
D-09D-09D-09
D-09
1
A801
2
A801
R @17
194.1 mm
700
FIRE RATED WALLS
BASIC MATERIALS TYPE % SOLID FIRE RATING ADDED MATERIALS STC FINAL FIRE
RATING
W1
W2
W4
W5
POURED CONCRETE
150 mm MIN.
140 CONCRETE BLOCK
WITH PRECAST PANEL
140mm CONCRETE
BLOCK
W6
123mm METAL STUD
WALL
W7
SHAFT ENCLOSURE
SHAFT ENCLOSURE
N
N
N
N
N
ULC W 407
OR
ULS W 415
2 LAYER 12.7 TYPW X GYPSUM
WALLBOARD BOTH SIDES
38mm SOUND BLANKETS (BY C.G.C)
55+ 2 HRS.
100%
STD
ULC W 507
U OF C 2-
8-72
4.0 HRS.
12.7mm DRYWALL LAMINATED TO
BLOCK IN FINISHED AREAS
NOTES:
N = NORMAL WEIGHT
L = LIGHT WIRGHT
STC = SOUND TRANSMISSION CLASS
USE "WONDER BOARD" OR EQUAL AT ALL SHOWER AND TUB LOCATION
ALL MECHANICALLY FASTENED GYPSUM WALLBOARDS TO BE IN ACCORDANCE WITH
CSA. A82.31-2012 "GYPSUM WALLBOARD APPLICATION"
ABBREVIATIONS:
AD. AREA DRAIN
C.J. CONTROL JOINT
E.J. EXPANSION JOINT
E.P. ELECTRICAL PANEL
F.F.E. FINISH FLOOR ELEVATION
F.H.C. FIRE HOSE CABINET
L.W. LOW WALL
P.S PIPE SPACE
RD. ROOF DRAIN
S.P. SECURITY PANEL
T.O.C. TOOP OF CURB
T.O.W. TOP OF WALL
U.P. UNIT PANEL
W.I.C. WALK-IN CLOSET
PRECAST PANELS
ALL DESIGN, MANUFACTURE AND INSTALLATION TO CONFORM TO N.B.C. AND C.S.A. 3 – A23. 4-94. LATEST
EDITION
PRECAST SUPPLIES IS RESPONSIBLE FOR DESIGN OF ALL PRECAST PANELS AND THEIR CONNECTIONS. THESE
CONNECTIONS TO INCLUDE THE REQUIRED INSERTS. ANCHORS AND BRACES TO BE EMBEDDED IN, OR
CONNECTED TO THE BUILDING STRUCTURE.
ALL PRECAST CONCRETE DESIGN AND SHOP DRAWINGS TO BE SUBMITTED FOR REVIEW. CARRYING THE STAMP OF
A REGISTERED PROFESSIONAL ENGINEER.
ALL CONNECTION TO BE DESIGNED IN SUCH A MANNER AS NOT TO CAUSE LOCAL OVERSTRESSING OF THE
SURROUNDING CONCRETE OR STRUCTURAL STEEL AND TO BE WHOLLY SUFFICIENT BY THEMSELVES, WITHOUT ANY
FURTHER REINFORCING, UNLESS SO STATED BY THE MANUFACTURER.
123 mm INTERIOR PARTITION
STEEL STUD WALL 1-HRS. RATING
150 mm POUR CONCRETE
PRECAST PANEL WALL
CONCRETE BLOCK WITH PRECAST PANEL
W2
W1
W3
W4
W5
W6
CONCRETE WALL WITH GYPSUM ON
INTERIOR
150mm POUR CONCRETE
ELEVATOR SHAFT
150mm POUR CONCRETEW7
WALL LEGEND
WALL TYPEWALL # ILUSTRATION
NN
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
1 : 100
LEVEL 4 PLAN A
0001
HARBOUR QUEEN
P1
12/02/14
Author
Checker
A308
1 : 100A308
Level 4 Final WD 100 A1
No. Description Date
13. UP
D
D
C C
B B
H H
J
J
K
K
E E
G G
A A
8
8
9
9
10
10
11
11
12
12
13
13
14
14
10 m²
KITCHEN
5 m²
LAUNDRY
5 m²
BATH
9 m²
BED.
# 3
6 m²
BATH.
5 m²
WIC
4 m²
POWDER 6 m²
DINING
15 m²
LIVING11 m²
FOYER
8 m²
2 BEDROOM4 m²
LAUNDRY
3 m²
WIC
6 m²
BATH.
14 m²
MASTER BED.
6 m²
KITCHEN
1 m²
MECH
2 m²
MECH
25 m²
BEDROOM
5 m²
WIC
6 m²
HALLW.
4 m²
BATH
14 m²
DEN
4 m²
POWDER
6 m²
LAUNDRY
25 m²
LIV/BEDROOM8 m²
DINING
8 m²
KITCHEN
Not Enclosed
BALCONY
6000 6000 6000 6000 6000 6000
22075
450115034222578513834221514
2 m²
FOYER
10 m²
BALCONY
21 m²
LIV/BEDROOM
16 m²
BALCONY
17 m²
BALCONY
9 m²
LIVING
6 m²
KITCHEN 4 m²
DEN
5 m²
BATH.
4 m²
LAUNDRY
5 m²
DINING
3 m²
FOYER
3 m²
WIC
4 m²
FOYER
8 m²
DEN9 m²
KITCHEN
10 m²
LIVING
7 m²
BEDROOM
6 m²
BATHROOM
4 m²
FOYER
3 m²
PWDR
5 m²
LAUNDRY
6 m²
DINING
9 m²
KITCHEN
21 m²
LIVING
10 m²
1 BEDROOM10 m²
2 BEDROOM
5 m²
WIC
5 m²
BATHROOM
17 m²
1 BEDROOM
10 m²
2 BEDROOM
7 m²
BATHROOM
3 m²
FOYER
19 m²
LIVING ROOM
13 m²
DINING
13 m²
KITCHEN
42 m²
CORRIDOR
16 m²
BALCONY
15 m²
BALCONY
8 m²
BALCONY
300 2289 335
518 1830
2714
2169
1539
9131264
439 813
100
6772301
139
813
223
2952
319 1830 540
D-01
D-01
D-01
D-01
D-01
D-01
D-01
600
841
3027622670
2976
2689
2500
278
1220 439
877
1814
2409
358 1220 359
2407813
323
7622013877
33971234628813
2689
44081525851
3438
8021814
250
2652
1814
2197877
9151306
5800
346 1461 2846
908
848
3600 2200
6301
2500
1508
5281730357
1070 813
323
813 1273
1984 1340 600
234
813 2174
2238131141
1568
3077
D-08
D-01
D-01
D-01
D-01 D-01
D-09
D-09
D-09
2839
2839
214
1300 337
75
706 762 457
1524
677
1487
2032
2867
6 m²
BEDROOM
934
873
1767
2032
1568
255
1657 762
1899675
2599
1634
1390520
47815682046
D-01
D-01
D-09
5191730348
575
D-09
D-01
3564
1551800
2251 1190
1786
851
957
2689
2084
803
787
2756
D-01
2471
9131770
1769
9131072
1302
122318301170
4000
2471
7624191220260
1071
1769
1289
1032 860
D-08
848
823
5789
3988
D-01
D-01
D-08
3201
2068
1130
5692
2873
1523 1293
2912584
1623 813
2143
795
1483
123817302463
1956
9621038
1754
12461064
1480
8391225
4197
5800
D-01
D-08
D-09
D-01
D-01
D-01
D-01
D-01
1972 740 1067 696 762 563
9231059
848
2918717
1800
1100
5800
2050
2569
2005
2449
1705
735
2131 2131
2254 1292
3003
1300
2246
2241
9361016
5236915485
5800
D-09
D-01
D-01
D-01
D-01
D-08
A.S.
6 m²
ELEVATOR
# 2
6 m²
ELEVATOR
# 3
7 m²
ELEVATOR
# 1
1500 2080 1500 1597
1099 1320 2031 1550
13759151240915791915193
W1
W2 W2
W1
W1
W2
W2
W2
W1
W2 W2
W1
W1
W2
W2
W6
W1
D-01
W2
W1
W2
W2
W2
W1
W2
W2
W1
W2
W2
W2
W2
W3
W2
W2
W1
W2
W2
W1
W2
W2
W2
W2
W2
W1
W1W1
W2
W2W1
W2
W1
W1
W6
W6
W1
W6
W7
D-11
D-12
D-11
4024 915 3885 915 7323 813 5036 915
915 12583 915 7462 915 2200
174
3
A801
4
A801
R @17
194.1 mm
700
FIRE RATED WALLS
BASIC MATERIALS TYPE % SOLID FIRE RATING ADDED MATERIALS STC FINAL FIRE
RATING
W1
W2
W4
W5
POURED CONCRETE
150 mm MIN.
140 CONCRETE BLOCK
WITH PRECAST PANEL
140mm CONCRETE
BLOCK
W6
123mm METAL STUD
WALL
W7
SHAFT ENCLOSURE
SHAFT ENCLOSURE
N
N
N
N
N
ULC W 407
OR
ULS W 415
2 LAYER 12.7 TYPW X GYPSUM
WALLBOARD BOTH SIDES
38mm SOUND BLANKETS (BY C.G.C)
55+ 2 HRS.
100%
STD
ULC W 507
U OF C 2-
8-72
4.0 HRS.
12.7mm DRYWALL LAMINATED TO
BLOCK IN FINISHED AREAS
NOTES:
N = NORMAL WEIGHT
L = LIGHT WIRGHT
STC = SOUND TRANSMISSION CLASS
USE "WONDER BOARD" OR EQUAL AT ALL SHOWER AND TUB LOCATION
ALL MECHANICALLY FASTENED GYPSUM WALLBOARDS TO BE IN ACCORDANCE WITH
CSA. A82.31-2012 "GYPSUM WALLBOARD APPLICATION"
ABBREVIATIONS:
AD. AREA DRAIN
C.J. CONTROL JOINT
E.J. EXPANSION JOINT
E.P. ELECTRICAL PANEL
F.F.E. FINISH FLOOR ELEVATION
F.H.C. FIRE HOSE CABINET
L.W. LOW WALL
P.S PIPE SPACE
RD. ROOF DRAIN
S.P. SECURITY PANEL
T.O.C. TOOP OF CURB
T.O.W. TOP OF WALL
U.P. UNIT PANEL
W.I.C. WALK-IN CLOSET
PRECAST PANELS
ALL DESIGN, MANUFACTURE AND INSTALLATION TO CONFORM TO N.B.C. AND C.S.A. 3 – A23. 4-94. LATEST
EDITION
PRECAST SUPPLIES IS RESPONSIBLE FOR DESIGN OF ALL PRECAST PANELS AND THEIR CONNECTIONS. THESE
CONNECTIONS TO INCLUDE THE REQUIRED INSERTS. ANCHORS AND BRACES TO BE EMBEDDED IN, OR
CONNECTED TO THE BUILDING STRUCTURE.
ALL PRECAST CONCRETE DESIGN AND SHOP DRAWINGS TO BE SUBMITTED FOR REVIEW. CARRYING THE STAMP OF
A REGISTERED PROFESSIONAL ENGINEER.
ALL CONNECTION TO BE DESIGNED IN SUCH A MANNER AS NOT TO CAUSE LOCAL OVERSTRESSING OF THE
SURROUNDING CONCRETE OR STRUCTURAL STEEL AND TO BE WHOLLY SUFFICIENT BY THEMSELVES, WITHOUT ANY
FURTHER REINFORCING, UNLESS SO STATED BY THE MANUFACTURER.
123 mm INTERIOR PARTITION
STEEL STUD WALL 1-HRS. RATING
150 mm POUR CONCRETE
PRECAST PANEL WALL
CONCRETE BLOCK WITH PRECAST PANEL
W2
W1
W3
W4
W5
W6
CONCRETE WALL WITH GYPSUM ON
INTERIOR
150mm POUR CONCRETE
ELEVATOR SHAFT
150mm POUR CONCRETEW7
WALL LEGEND
WALL TYPEWALL # ILUSTRATION
NN
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
1 : 100
LEVEL 4 PLAN B
0001
HARBOUR QUEEN
P1
12/02/14
Author
Checker
A309
1 : 100A309
Level 4 Final WD 100 B2
No. Description Date
14. .. ..
. .. .
UP UP
D D
C C
B B
H H
J J
K K
E E
F F
G G
A A
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
6000 6000 6000 6000 6000 6000 6000 6000 6000 6000
60000
4501150342225783538862513834221514
22075
2
A311
1
A312
FIRE RATED WALLS
BASIC MATERIALS TYPE % SOLID FIRE RATING ADDED MATERIALS STC FINAL FIRE
RATING
W1
W2
W4
W5
POURED CONCRETE
150 mm MIN.
140 CONCRETE BLOCK
WITH PRECAST PANEL
140mm CONCRETE
BLOCK
W6
123mm METAL STUD
WALL
W7
SHAFT ENCLOSURE
SHAFT ENCLOSURE
N
N
N
N
N
ULC W 407
OR
ULS W 415
2 LAYER 12.7 TYPW X GYPSUM
WALLBOARD BOTH SIDES
38mm SOUND BLANKETS (BY C.G.C)
55+ 2 HRS.
100%
STD
ULC W 507
U OF C 2-
8-72
4.0 HRS.
12.7mm DRYWALL LAMINATED TO
BLOCK IN FINISHED AREAS
NOTES:
N = NORMAL WEIGHT
L = LIGHT WIRGHT
STC = SOUND TRANSMISSION CLASS
USE "WONDER BOARD" OR EQUAL AT ALL SHOWER AND TUB LOCATION
ALL MECHANICALLY FASTENED GYPSUM WALLBOARDS TO BE IN ACCORDANCE WITH
CSA. A82.31-2012 "GYPSUM WALLBOARD APPLICATION"
ABBREVIATIONS:
AD. AREA DRAIN
C.J. CONTROL JOINT
E.J. EXPANSION JOINT
E.P. ELECTRICAL PANEL
F.F.E. FINISH FLOOR ELEVATION
F.H.C. FIRE HOSE CABINET
L.W. LOW WALL
P.S PIPE SPACE
RD. ROOF DRAIN
S.P. SECURITY PANEL
T.O.C. TOOP OF CURB
T.O.W. TOP OF WALL
U.P. UNIT PANEL
W.I.C. WALK-IN CLOSET
PRECAST PANELS
ALL DESIGN, MANUFACTURE AND INSTALLATION TO CONFORM TO N.B.C. AND C.S.A. 3 – A23. 4-94. LATEST
EDITION
PRECAST SUPPLIES IS RESPONSIBLE FOR DESIGN OF ALL PRECAST PANELS AND THEIR CONNECTIONS. THESE
CONNECTIONS TO INCLUDE THE REQUIRED INSERTS. ANCHORS AND BRACES TO BE EMBEDDED IN, OR
CONNECTED TO THE BUILDING STRUCTURE.
ALL PRECAST CONCRETE DESIGN AND SHOP DRAWINGS TO BE SUBMITTED FOR REVIEW. CARRYING THE STAMP OF
A REGISTERED PROFESSIONAL ENGINEER.
ALL CONNECTION TO BE DESIGNED IN SUCH A MANNER AS NOT TO CAUSE LOCAL OVERSTRESSING OF THE
SURROUNDING CONCRETE OR STRUCTURAL STEEL AND TO BE WHOLLY SUFFICIENT BY THEMSELVES, WITHOUT ANY
FURTHER REINFORCING, UNLESS SO STATED BY THE MANUFACTURER.
123 mm INTERIOR PARTITION
STEEL STUD WALL 1-HRS. RATING
150 mm POUR CONCRETE
PRECAST PANEL WALL
CONCRETE BLOCK WITH PRECAST PANEL
W2
W1
W3
W4
W5
W6
CONCRETE WALL WITH GYPSUM ON
INTERIOR
150mm POUR CONCRETE
ELEVATOR SHAFT
150mm POUR CONCRETEW7
WALL LEGEND
WALL TYPEWALL # ILUSTRATION
NN
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
As indicated
PENTHOUSE
FLOOR PLAN
0001
HARBOUR QUEEN
P1
12/02/14
Author
Checker
A310
1 : 200A310
PENTHOUSE LEVEL 81
No. Description Date
15. . .DN
H H
J J
K K
F F
G G
1
A501
3
3
4
4
5
5
6
6
7
7
34 m²
MASTER
BED.
28 m²
MASTER
BATH.
30 m²
BED.
#2
32 m²
BED.
# 1
OPEN TO BELOW
R @18
183.3 mm
1575 3079
5798
2079
5798
3789
674 4520 1500
4801
3399
3477
4801
1300
4910
4801
1549
2989
1186
1123
W2
W2
W2
W3
W2
W2
W2
W2
W1
W3
GLASS RAILING
6000 6000 6000 6000
862513834221514
6000 6000 6000 6000
24000
24000
862513834221514
H H
J J
K K
F F
G G
1
A501
3
3
4
4
5
5
6
6
7
7
6000 6000 6000 6000
27250
W1
46 m²
LIVING ROOM
27 m²
DEN
28 m²
DINING ROOM
27 m²
KITCHEN
11 m²
LAUNDRY
28 m²
FAMILY ROOM
14 m²
LIBRARY
8 m²
BATHROOM
16 m²
FOYER
5762
63349375152098
950 528 1830 417 1830
723
1166 4500
1830
5877
4543
18001350
6000
1000
1186
3237
3150
1048 813
4715
1676
3150
D-08 D-01
D-15
W1 W2
W2
W1
W2
W2
W3
W3
W2
W1
5127
862513834221514
R @17
194.1 mm
700
NN
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
1 : 100
PENTHOUSE
FLOOR PLAN A
0001
HARBOUR QUEEN
P1
12/02/14
Author
Checker
A311
1 : 100A311
PENTHOUSE PLAN A UPPER LEVEL1
1 : 100A311
PENTHOUSE PLAN A LOWER LEVEL2
No. Description Date
16. . . DN
DN
H H
J J
K K
F F
I I
G G
L L
1
A501
8
8
9
9
10
10
11
11
12
12
13
13
-
---
23 m²
1 BEDROOM 24 m²
DINING ROOM
39 m²
LIVING ROOM
9 m²
FOYER
21 m²
KITCHEN
10 m²
BATH.
A.S. 1533 813
4294 813
5316
3409
2471
3991
4083 1756
3413
1158
1123
1158
902
3409
2741
5960
723
582
6000
4012
1500
1662
D-01
D-01
D-15
OPEN TO ABOVE
D-09
D-09
D-09
7 m²
ELEV.
# 1
1500 2080 1500 1597
1099 1320 2031 1550
13129151092915
9716 1829 5365 915
6000 6000 6000 6000 6000
30000
8625138342215141163762
8625138342215141163762
12862
12862
6000 6000 6000 6000 6000
30000
R @17
194.1 mm
W6
W2
W2
W2
W1
W6
W6
W3
W2
W2
W6
1149
700
H H
J J
K K
F F
I I
G G
L L
1
A501
9
9
10
10
11
11
12
12
-
---
30 m²
MASTER
BED.
28 m²
MASTER
BATH.
15 m²
BED.
# 1
15 m²
BED.
# 2
10 m²
BATHROOM
5839
5269
978 3200
1038 679 1721 679 1721
3729
2055
1289
4876
388 1500 1247
23791300
1844
1956
3228
1500 1635
1563
1123
1158
OPEN TO BELOW
R @18
183.3 mmGLASS RAILING
W1
W2
W2
W2
W3
W2
W3
W2
6000 6000 6000
18000
W3
NN
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
1 : 100
PENTHOUSE
FLOOR PLAN B
0001
HARBOUR QUEEN
P1
12/02/14
Author
Checker
A312
1 : 100A312
PENTHOUSE PLAN B LOWER LEVEL1
1 : 100A312
PENTHOUSE PLAN B UPPER LEVEL2
No. Description Date
17. Level 1
0
Level 2
5000
Level 3
10000
Level 4
13300
Level 5
16600
Level 6
19900
Level 7
23200
Level 8
26500
Level 9
29800
Level 10
33100
TOP
36600
Level 1
0
Level 2
5000
Level 3
10000
Level 4
13300
Level 5
16600
Level 6
19900
Level 7
23200
Level 8
26500
Level 9
29800
Level 10
33100
TOP
36600
NN
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
1 : 200
NORHT & SOUTH
ELEVATION
0001
HARBOUR QUEEN
P1
12/02/14
Author
Checker
A401
1 : 200A401
NORTH ELEVATION WD1
1 : 200A401
SOUTH ELEVATION WD2
1
2
3
4
5
6
7
8
9
PRE-CAST PANEL COLOUR A
PRE-CAST PANEL COLOUR B
PRE-CAST PANEL COLOUR C
CLEAR GLASS
TITANIUM FINISH
TINTED GLASS
1
1
1
2
22
2
2
2 2
2
2
2
3
3
3
3
44
4
4
5
5
5
5
5
5
5
5
1
11
1
2
2
2
2
2
2
2
2
2
2
4
4
4
4
4
4
4
4
4 5
5
5
5
5
5
No. Description Date
18. Level 1
0
Level 2
5000
Level 3
10000
Level 4
13300
Level 5
16600
Level 6
19900
Level 7
23200
Level 8
26500
Level 9
29800
Level 10
33100
TOP
36600
NN
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
1 : 200
WEST ELEVATION
0001
HARBOUR QUEEN
P1
12/02/14
Author
Checker
A402
1 : 200A402
WEST ELEVATION WD1
1
2
3
4
5
6
7
8
9
PRE-CAST PANEL COLOUR A
PRE-CAST PANEL COLOUR B
PRE-CAST PANEL COLOUR C
CLEAR GLASS
TITANIUM FINISH
TINTED GLASS
1
1
1
2
2
2
2
2
2
2
2
2
2
3
5 5
5
55
5
5
5
4
4
4
4
No. Description Date
19. Level 1
0
Level 2
5000
Level 3
10000
Level 4
13300
Level 5
16600
Level 6
19900
Level 7
23200
Level 8
26500
Level 9
29800
Level 10
33100
TOP
36600
NN
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
1 : 200
EAST ELEVATION
0001
HARBOUR QUEEN
P1
12/02/14
Author
Checker
A403
1 : 200A403
EAST ELEVATION WD1
1
2
3
4
5
6
7
8
9
PRE-CAST PANEL COLOUR A
PRE-CAST PANEL COLOUR B
PRE-CAST PANEL COLOUR C
CLEAR GLASS
TITANIUM FINISH
TINTED GLASS
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
3
3 3
3
3
3
3
33
3
4
4
4
4
4
4 4
4
4
5
5
5
5
5
5
6
6
6
6
6
6
6
6
6
No. Description Date
20. Level 1
0
Level 2
5000
Level 3
10000
Level 4
13300
Level 5
16600
Level 6
19900
Level 7
23200
Level 8
26500
Level 9
29800
Level 10
33100
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16
LIFT LIFT
6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000
330033003300330033003300330050005000
33100
29800
26500
23200
19900
16600
13300
10000
5000
0
TOP
36600
3500
1
A802
2
A802
NN
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
1 : 200
CROSS SECTION
0001
HARBOUR QUEEN
P1
12/02/14
Author
Checker
A501
1 : 200A501
BUILDING SECTION1
No. Description Date
21. 1
10000
5000
PRE-FIN. ALUM. RAILING
WITH SAFETY GLASS
ALUMINIUM CASTING SHOE
(REFER TO APPROVED SHOP
DRAWINGS FOR CONNECTION
DETAILS)
455455250300
PRE-FIN.
ALUM. FRAME
WITH SEALED
DOUBLE
GLAZED
PRE-FIN.
ALUM. FRAME
WITH SEALED
DOUBLE
GLAZED
BACK PAINTED GLASS
25mm AIR SPACE
45mm ROXUL FLEXIBLE BATT INSU.
92mm STEEL STUD @ 400mm O/C
FURRING, 89mm BATT INSULATION
6 MIL VAPOUR BARRIER
13mm GYPSUM WALL BOARD
13mm GYPSUM BOARD (STAGGERED)
FURRING CHANELS @ 600 O/C
SUSPENSION CHANNELS @ 1200 O/C
50mm RIGID INSUL. OR MINERAL WOOL
SUSPENSION WIRES
POURED CONC. SLAB 250mm
CONCRETE FOOTING
600x300x300mm
STUCCO FINISH
10mm CEMENT WALL BOARD, MECH. FAST.
25mm METAL HAT CHANNEL
50mm RIGID INSUL.
150mm SHEAR CONCRETE WALL
89mm BATT INSUL. (RSI-2.11)
92mm STEEL STUD @ 400 mm O/C
6 MIL VAPOUR BARRIER
13mm GYPSUM WALL BOARD
FINISH
FLOOR
SLAB
250250
PRE-FIN.
ALUM. FRAME
WITH SEALED
DOUBLE
GLAZED
630
PARKING
P1
PARKING
P4
LEVEL 1
LEVEL 2
0
GROUND
LEVEL
-13450
P4
EXPANSION
JOINT
CONC.SLAB
350 mm FOUNDATION WALL
POLYMER-MODIFIED
ASPHALT
50mm RIGID INSUL.
FINISH
FLOOR
SLAB
BACK PAINTED GLASS
25mm AIR SPACE
45mm ROXUL FLEXIBLE BATT INSU.
92mm STEEL STUD @ 400mm O/C
FURRING, 89mm BATT INSULATION
6 MIL VAPOUR BARRIER
13mm GYPSUM WALL BOARD
STUCCO FINISH
10mm CEMENT WALL BOARD, MECH. FAST.
25mm METAL HAT CHANNEL
50mm RIGID INSUL.
150mm SHEAR CONCRETE WALL
89mm BATT INSUL. (RSI-2.11)
92mm STEEL STUD @ 400 mm O/C
6 MIL VAPOUR BARRIER
13mm GYPSUM WALL BOARD
FINISH
FLOOR
SLAB
13mm GYPSUM BOARD (STAGGERED)
FURRING CHANELS @ 600 O/C
SUSPENSION CHANNELS @ 1200 O/C
50mm RIGID INSUL. OR MINERAL WOOL
SUSPENSION WIRES
POURED CONC. SLAB 250mm
4270275
457x457MM CONCRETE
COLUMN
1
A802
14
SUITE
SUITE
SUITE
23200
19900
16600
STUCCO FINISH
10mm CEMENT WALL BOARD,MECH.FASTENED
25mm METAL HAT CHANNEL
@405 O/C SPACING
50mm RIGID INSULATION
150mm CONCRETE WALL
89mm BATT INSUL. (RSI-2.11)
92mm STEEL STUD @ 400 mm O/C FURRING
6 MIL VAPOUR BARRIER
13mm GYPSUM WALL BOARD
BACK PAINTED GLASS
25mm AIR SPACE
45mm ROXUL FLEXIBLE BATT INSUL.
(RSI-1.15)
92mm STEEL STUD @ 400mm O/C FURRING
89mm BATT INSULATION (RSI- 2.11)
6 MIL VAPOUR BARRIER
13mm GYPSUM WALL BOARD
BACK PAINTED GLASS
25mm AIR SPACE
45mm ROXUL FLEXIBLE BATT INSUL.
(RSI-1.15)
92mm STEEL STUD @ 400mm O/C FURRING
89mm BATT INSULATION (RSI- 2.11)
6 MIL VAPOUR BARRIER
13mm GYPSUM WALL BOARD
BACK PAINTED GLASS
25mm AIR SPACE
45mm ROXUL FLEXIBLE BATT INSUL.
(RSI-1.15)
92mm STEEL STUD @ 400mm O/C FURRING
89mm BATT INSULATION (RSI- 2.11)
6 MIL VAPOUR BARRIER
13mm GYPSUM WALL BOARD
ALUMINIUM CASTING SHOE
(REFER TO APPROVED SHOP
DRAWINGS FOR CONNECTION
DETAILS)
ALUMINIUM CASTING SHOE
(REFER TO APPROVED SHOP
DRAWINGS FOR CONNECTION
DETAILS)
ALUMINIUM CASTING SHOE
(REFER TO APPROVED SHOP
DRAWINGS FOR CONNECTION
DETAILS)
FINISH
FLOOR
SLAB
FINISH
FLOOR
SLAB
FINISH
FLOOR
SLAB
PRE-FIN.
ALUM. FRAME
WITH SEALED
DOUBLE
GLAZED
PRE-FIN.
ALUM. FRAME
WITH SEALED
DOUBLE
GLAZED
PRE-FIN. ALUM. RAILING
WITH SAFETY GLASS
PRE-FIN. ALUM. RAILING
WITH SAFETY GLASS
LEVEL 7
LEVEL 6
LEVEL 5
0
GROUND
LEVEL
BACK PAINTED GLASS
25mm AIR SPACE
45mm ROXUL FLEXIBLE BATT INSUL.
(RSI-1.15)
92mm STEEL STUD @ 400mm O/C FURRING
89mm BATT INSULATION (RSI- 2.11)
6 MIL VAPOUR BARRIER
13mm GYPSUM WALL BOARD
13mm GYPSUM BOARD (STAGGERED)
FURRING CHANELS @ 600 O/C
SUSPENSION CHANNELS @ 1200 O/C
50mm RIGID INSUL. OR MINERAL WOOL
SUSPENSION WIRES
POURED CONC. SLAB 250mm
PRE-FIN.
ALUM. FRAME
WITH SEALED
DOUBLE
GLAZED
2
A802
25055025002500250550
1030
250
634
634
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
1 : 25
WALL SECTIONS
0001
Harbour Queen
P1
12/02/14
Author
Checker
A6011 : 25A601
SOUTH WALL SECTION2
1 : 25A601
NORTH WALL SECTION1
No. Description Date
22. 3
BYCICLE STORAGE
AMENITIES
GAMES ROO M
PRE FARBRICATED PANEL
INSTALLED FIRST.
64mm RIGID INSULATION.
92mm METAL STUD SPACED
@ 400mm O/C.
89mm BATT INSUL.
13mm GYPSUM WALL
BOARD
PRE-FIN. ALUM. RAILING
WITH SAFTEY GLASS
ALUMINIUM CASTING SHOE
(REFER TO APPROVED SHOP
DRAWINGS FOR
CONNECTION
DETAILS)
PENTHOUSE
UNIT. 804
METAL CAP FLASHING
115mm PRECAST PANEL
50mm RIGID INSUL.
FIBE RBOARD
ASPHALT FELT FLASHING
ALUMINIUM CASTING SHOE
(REFER TO APPROVED
SHOP
DRAWINGS FOR
CONNECTION
DETAILS)
PRE-FIN. ALUM.
RAILING
WITH SAFTEY GLASS
GRADEFIN. FL. SLAB
FIN. FL. SLAB
FIN. FL. SLAB
BACK PAINTED GLASS
25mm AIR SPACE
45mm ROXUL FLEXIBLE. BATT INSULATION (RSI-
1.15)
92mm STEEL STUD @ 400mm
0/C FURRING
89mm BATT INSUL. (RSI-2.11)
6MIL VAPOUR BARRIER
13mm GYPSUM WALL BOARD
250 CONCRETE SLAB
50mm RIGID INSUL.
SUSPENSION WIRES
89mm SOUND
INSULATION
13mm GYPSUM BOARD
250mm CONCRETE SLAB
550350250
493250
930
930
A802
G H
GROUND LEVEL
0
Level 3
10000
Level 8
26500
Level 10
33100
151
FIN. FL. SLAB
WATERPROOF PAINT
PRE-FIN. ALUM. FRAME WITH SEALED
DOUBLE GLAZED
STUCCO FINISH
10mm CEMENT WALL BOARD
50mm RIGID INSUL.
350 mm CONCRETE SHEAR WALL
92 mm STELL STUD @ 400mmO.C FURRING
89 BATT INSUL. (RSI - 2.11)
6 MIL VAPOUR BARRIER
13mm GYPSUM BOARD
PRE-FIN. ALUM. RAILING
WITH SAFETY GLASS
ALUMINIUM CASTING SHOE
(REFER TO APPROVED SHOP
DRAWINGS FOR CONNECTION
DETAILS)
BACK PAINTED GLASS
25mm AIR SPACE
45mm ROXUL FLEXIBLE BATT INSUL.
92 mm STELL STUD @ 400mmO.C
FURRING
89 BATT INSUL. (RSI - 2.11)
6 MIL VAPOUR BARRIER
13mm GYPSUM BOARD
PRE-FIN. ALUM. FRAME WITH
SEALED
DOUBLE GLAZED
FINISH FLOOR SLAB
SUITE
PRE-FIN. ALUM. RAILING
WITH SAFETY GLASS
ALUMINIUM CASTING SHOE
(REFER TO APPROVED SHOP
DRAWINGS FOR CONNECTION
DETAILS)
BACK PAINTED GLASS
25mm AIR SPACE
45mm ROXUL FLEXIBLE BATT INSUL.
(RSI - 1.15)
AIR BARRIER
92 mm STELL STUD @ 400mmO.C
FURRING
89 BATT INSUL. (RSI - 2.11)
6 MIL VAPOUR BARRIER
13mm GYPSUM BOARD
FINISH FLOOR SLAB
SUITE
PRE-FIN. ALUM. FRAME WITH
SEALED
DOUBLE GLAZED
PRE-FIN. ALUM. RAILING
WITH SAFETY GLASS
ALUMINIUM CASTING SHOE
(REFER TO APPROVED SHOP
DRAWINGS FOR CONNECTION
DETAILS)
FINISH FLOOR SLAB
SUITE
SUITE
STUCCO FINISH
10mm CEMENT WALL BOARD
50mm RIGID INSUL.
150 mm CONCRETE WALL
92 mm STELL STUD @ 400mmO.C
FURRING
89 BATT INSUL. (RSI - 2.11)
6 MIL VAPOUR BARRIER
13mm GYPSUM BOARD
FINISH FLOOR SLAB
600 X 600mm
CONCRETE COLUMN
BITUMINOUS MEMBRANE
50mm RIGID INSULATION
13 mm GYPSUM BOARD (STAGGERED)
FURRING CHANELS @ 600 O/C
SUSPENSION CHANNELS @ 1200 O/C
50 mm RIGID INSUL. OR MINERAL
WOOL
SUSPENSION WIRES
POURED CONC. SLAB 250mm
13 mm GYPSUM BOARD (STAGGERED)
FURRING CHANELS @ 600 O/C
SUSPENSION CHANNELS @ 1200 O/C
50 mm RIGID INSUL. OR MINERAL
WOOL
SUSPENSION WIRES
POURED CONC. SLAB 250mm
13 mm GYPSUM BOARD (STAGGERED)
FURRING CHANELS @ 600 O/C
SUSPENSION CHANNELS @ 1200 O/C
50 mm RIGID INSUL. OR MINERAL
WOOL
SUSPENSION WIRES
POURED CONC. SLAB 250mm
P1
LEVEL 9
LEVEL 5
LEVEL 3
GROUND
LEVEL
WATERPROOF PAINT
STUCCO FINISH
10mm CEMENT WALL BOARD W/ WIRE
MESH
50mm RIGID INSUL.
150 mm CONCRETE WALL
92 mm STELL STUD @ 400mmO.C
FURRING
89 BATT INSUL. (RSI - 2.11)
6 MIL VAPOUR BARRIER
13mm GYPSUM BOARD
RETAIL
250mm CONCRETE SLAB
930250550
550250
250490
250
250
29800
16600
10000
0
4
A802
B A
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
1 : 25
WALL SECTIONS
0001
Harbour Queen
P1
12/02/14
A6021 : 25A602
EAST WALL SECTION1
1 : 25A602
WEST WALL SECTION2
No. Description Date
23. A A
A5 A5
1
1
60100252660
DOUBLE GLAZED THERMALLY BROKEN
ALUM. WINDOWS
(SHOP DWGS REQUIRED)
BALCONY
UNIT
415
115mm PECAST PANEL TYP.
25mm AIR SPACE
50mm RIGID INSUL.
STRUCTURAL CONC. SHEAR WALL
13mm GYPSUM WALL BOARD
STOREFRONT
SINGLE PANEL
GLASS DOOR
1900x1200mm
FOAM IN PLACE
INSUL.
FIRE STOP MAT.
COMPRESSED
NON-COMBUSTIBLE
SEIRIGID MINERAL
FIBRE MATERIAL
2HR RATED
115mm PRECAST PANEL TYP.
50mm RIGID INSUL.
92mm STEEL STUD
89mm BATT INSUL.
6MIL VAPOUR BARRIER
13mm GYPSUM WALL BOARD
W3
A A
A5 A5
7
7
BALCONY115mm PRECAST PANEL TYP.
25 mm AIR SPACE
50.8mm RIGID INSULATION
STRUCT. CONC. SHEARWALL
13mm GYPSUM BOARD
150 MM
SHEAR WALL
w/ 13mm GYPSUM BOARD ON BOTH
SIDES
SEAL VAPOUR BARRIER
AND AIR BARRIER TO SHEAR WALL WITH
SPECIFIED SEALANT
FIRESTOPING MATERIAL
COMPRESSED
NON-COMBUSTIBLE
SEMIRIGID MINERAL FIBRE
MATERIAL SMOKE SEAL
SPRAY ON BOTH SIDES
SUITE
408
SUITE
408
MECHANICAL
ROOM
92mm STEEL STUD
w/ 13mm GYPSUM
BOARD
89mm SOUND.
INSUL.
PRE-FIN. ALUM. FRAME
WITH SEALED DOUBLE
GLAZED
PRE-FIN. ALUM.
FRAME WITH
SEALED DOUBLE
GLAZED
FOAM IN PLACE INSUL.
FOAM IN PLACE
INSUL.
W1
W2
W3
11
11
STAIR SHAFT
UNIT 403
UNIT 405
92mm STEEL STUD
89mm SOUND INSUL.
W/13mm GYPSUM
BOARD ON BOTH
SIDES
(1HR FIRE RATING)
150mm SHEAR WALL
92mm STEEL STUD
89mm SOUND INSUL.
13mm GYPSUM BOAD
450mm RADIUS
STAIR RAILING
150mm ELEVATOR
SHAFT WALL
13mm GYPSUM BOARD
W1
W2
W6
20 20
21 21
22
22
BALCONY
SUITE
350 mm STRUCTURAL CONCRETE
SHEAR WALL
89mm BATT INSULATION
92mm STEEL STUDS & 400mm O.C FURR.
6 mil POLYETHYLENE VAPOUR BARRIER
13mm GYPSUM BOARD FINISH
150 mm SHEAR WALL WITH 1hr FIRE SEPARETION.
6 mm STUCCO
10 mm CEMENT BOARD + WIRE MESH
2" (50.8mm) EXTERIOR RIGID INSULATION
350 mm STRUCTURAL CONCRETE SHEAR
WAL
CLOSET
MASTER BEDROOM PRE-FIN. ALUM. FRAME WITH SEALED
DOUBLE GLAZED
SEAL VAPOR BARRIER AND AIR
BARRIER
TO SLAB WITH SPECIFIED SEALANT
PRE-FIN. ALUM. RAILING
WITH SAFETY GLASS
FIRESTOPING MATERIAL
60mm COMPRESSED
NON-COMBUSTIBLE SEMIRIGID
MINERAL FIBRE MATERIAL
SMOKE SEAL SPRAY ON BOTH
SIDES
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
1 : 10
PLAN DETAILS
0001
Harbour Queen
P1
12/02/14
Author
Checker
A801
1 : 10A801
EXTERIOR WINDOW PLAN DETAIL1
1 : 10A801
PLAN DETAIL - 4th FLOOR2
1 : 10A801
STAIR SHAFT PLAN DETAIL4
1 : 10A801
BALCONY DETAIL AT 3rd-6th FL.3
No. Description Date
24. 3
SUITEBALCONY 6 mm STUCCO
10mm CEMENT BOARD + WIRE MESH
50mm EXTERIOR RIGID INSULATION
350 mm STRUCTURAL CONCRETE SHEAR WALL
92mm STEEL STUD WITH FIBERGLASS 89mm BATT
INSULATION
6MIL VAPOUR BARRIER
13mm GYPSUM WALL BOARD
20mm RAISED SLAB FROM
250mm CONCRETE SLAB
SLOPE TO EDGE
SEAL VAPOR BARRIER AND AIR BARRIER TO SLAB WITH
SPECIFIED SEALANT
BASEBOARD
ACCOUSTICALLY SUSPENDED CEILING
WATERPROOFING
PAINT
RAILING POST
24X40mm THICK
ALUMINIUM
PROFILE
TOP RAIL
TYPE: ELIPTICAL
30X40mm
SUSPENSION
WIRE
STEELSTUD
92mm
NON-COMBUSTIBLE
ROXUL SOUND INSUL.
2" (50.8mm) THICK
12mm GYPSUM
BOARD ON THE
CEILING
FINISHED FLOOR SLAB
250mm CONC.
SLAB
12 13
SUITE BALCONY
1030
EXTERIOR CURTAIN
WALL WITH GLAZING
ON THE OUTSIDE
150mm THICK
ALUMINIUM PROFILES
ALUMINIUM CASTING SHOE
(REFER TO APPROVED SHOP
DRAWINGS FOR CONNECTION
DETAILS)
WATERPROOF PAINT
5mm THICK GLASS PANEL
TOP RAIL
TYPE: ELIPTICAL
30X40mm
50mm ALUMINIUM PROFILE
OF THE RAILING
MAIN RAILING POST
24X40mm ALUMINIUM
PROFILE
10mm CEMENT BOARD W/ WIRE MESH
50mm RIGID INSUL.
350mm THICK EXTERIOR SHEAR WALL
92mm STEELS STUD W/ 89mm BATT INSUL.
6MIL VAPOUR BARRIER
13mm GYPSUM WALL BOARD
ACCOUSTICALLY SUSPENDED CLG
250MM CONCRETE SLAB
NON COMBUSTIBLE
ROXUL SOUND INSULATION
2" (50.8mm) THICK
12mm GYPSUM
BOARD
92mm STEEL STUD
1030
20mm RAISED SLAB
STOREFRONT
DOOR HANDLE
75mm GRAVEL BALLAST
GEOTEXTILE FILTER FABRIC
2 LAYERS 50mm RIGID
INUSLATION
ROOFING MEMBRANE
250 mm CONCRETE SLAB
SLOPE TO DRAIN MIN 2%
CAST IN PLACE
ANCHOR
BITUMINOUS
MEMBRANE
TAPERED WOOD
BLOCKING
METAL CAP FLASHING
115mm PRECAST PANEL
50mm RIGID INSUL.
FIBE RBOARD
ASPHALT FELT FLASHING
SHEAR CONNECTION
CAST INTO PANEL C/W LEVELING
BOLT FILL WITH URETHANE FOAM
6mm STUCCO FINISH
10 mm CEMENT BOARD + WIRE MESH
2" (50.8) mm EXTERIOR RIGID iNSUL.
350mm STRUCTURAL CONCRETE
SHER WALL
89mm BATT INSUL. (RSI - 2.11)
92mm STEEL STUD @ 400mm O/C
FURRING
6mil VAPOUR BARRIER
13mm GYPSUM WALL BOARD
FINISH FLOOR
SLAB
ACCOUSTICALLY SUSPENDED CEILING
13 mm GYPSUM BOARD (STAGGERED)
FURRING CHANELS @ 600 O/C
SUSPENSION CHANNELS @ 1200 O/C
50 mm RIGID INSUL. OR MINERAL
WOOL
SUSPENSION WIRES
POURED CONC. SLAB 250mm
PRE-FIN. ALUM. FRAME
WITH SEALED
DOUBLE GLAZED GLASS
A A5
Scale
Checked by
Drawn by
Date
Project number
THE CONTRACTOR MUST VERIFY
AND ACCEPT RESPONSIBILITY FOR
ALL DIMENSIONS AND CONDITIONS
ON SITE AND MUST NOTIFY
ARCHITECTURAL FIRM OF ANY
VARIOTIONS FROM THE SUPPLIED
INFORMATION. FIRM IS NOT
RESPONSIBLE FOR THE ACCURACY
OF THE SURVEY, STRUCTURAL,
MECHANICAL, ETC., ENGINEERING
INFORMATION SHOWN ON THESE
DRAWINGS.
REFER TO THE APPROPRIATE
ENGINEEING DRAWINGS BEFORE
PROCEEDING WITH THE WORK.
CONSTRUCTION MUST CONFORM TO
ALL APPLICABLE CODES AND
REQUIREMENTS OF AUTHORITIES,
DRAWINGS ARE NOT TO BE SCALED,
ARCHITECTURAL SYMBOLS ARE
GRAPHIC PRESENTATIONS ONLY.
HQDesign
1 : 10
SECTION DETAILS
0001
Harbour Queen
P1
12/02/14
P1
Checker
A802
1 : 10A802
EXTERIOR & INTERIOR WALL1
1 : 10A802
GLASS BALCONY RAILING2
1 : 10A802
ROOF PARAPET CONNECTION3
1 : 10A802
EXTERIOR WALL SECTION DETAIL4
No. Description Date
25. SHEET NUMBER:
DATE:
SCALE:
ARCHITECTURAL TECHNOLOGY AND SUSTAINABLE DESIGN
ARCH 3008
SANDRA SEBANEK 100859424
ANASTASIIA SKOROBOHACH 100857317
DILLON CLARKE 100766647
BOJAN KARANOVIC 100347529
SHEET NAME:
MARLENE SLOPACK
COVER PAGE
02/12/15
A100
Sheet List
Sheet Name Sheet Number
COVER PAGE A100
SITE PLAN A101
UNIT A A102
UNIT B A103
UNIT C A104
UNIT D A105
FRONT
ELEVATION
A106
SOUTH SIDE
ELEVATION
A107
FRONT
ELEVATION UNIT
A
A108
FRONT
ELEVATION UNIT
B
A109
FRONT
ELEVATION UNIT
C
A110
FRONT
ELEVATION UNIT
D
A111
27. 750
18 m²
RECEPION
5 m²
FEMALE
WASHROOM
5 m²
MALE
WASHROOM
7 m²
EXAM ROOM #1
8 m²
EXAM ROOM #2
7 m²
NURSES STATION
4 m²
FILE ROOM
5 m²
OFFICE
4 m²
RESIDENTIAL
GARBAGE RM.
4 m²
COMERCIAL
GARBAGE RM.
11 m²
BEDROOM 1
11 m²
BEDROOM 2 6 m²
BATHROOM
2 m²
W/D
9 m²
DINING ROOM
8 m²
KITCHEN
18 m²
LIVING ROOM
10 m²
HALLWAY
7 m²
FOYER
NN
SHEET NUMBER:
DATE:
SCALE:
ARCHITECTURAL TECHNOLOGY AND SUSTAINABLE DESIGN
ARCH 3008
SANDRA SEBANEK 100859424
ANASTASIIA SKOROBOHACH 100857317
DILLON CLARKE 100766647
BOJAN KARANOVIC 100347529
SHEET NAME:
MARLENE SLOPACK
1 : 75
UNIT A
02/12/15
A102
1 : 75A102
GROUND FLOOR UNIT A - MEDICAL CENTER1
1 : 75A102
SECOND FLOOR UNIT A - 2 BEDROOM RESIDENTIAL2
28. 12 m²
BOARDROOM
6 m²
MALE
6 m²
FEMALE
8 m²
LUNCH ROOM
59 m²
LAW OFFICE
GARBAGE
ROOM
ELECTR.
1
A108
14 m²
LIVING
5 m²
FOYER
11 m²
KITCHEN
11 m²
DNING
5 m²
BATH
1 m²
WIC
11 m²
BEDROOM
6 m²
BATH
2 m²
WIC
12 m²
MASTER BED
4 m²
DENCLOSET
NN
SHEET NUMBER:
DATE:
SCALE:
ARCHITECTURAL TECHNOLOGY AND SUSTAINABLE DESIGN
ARCH 3008
SANDRA SEBANEK 100859424
ANASTASIIA SKOROBOHACH 100857317
DILLON CLARKE 100766647
BOJAN KARANOVIC 100347529
SHEET NAME:
MARLENE SLOPACK
1 : 75
UNIT B
02/12/15
A103
1 : 75A103
GROUND FLOOR UNIT B - LAW OFFICE1
1 : 75A103
SECOND FLOOR UNIT B - 2 BEDROOM RESIDENTIAL2
29. GARBAGE
ROOM
GARBAGE
CHUTE
750
FRIDGES
CASHIER
SHELVING
7 m²
STORAGE
71 m²
VARIETY STORE
GARBAGE
CHUTE
4 m²
W/D
8 m²
KITCHEN
18 m²
LIVING ROOM
12 m²
BEDROOM
11 m²
SUN ROOM
DEN
6 m²
DINING
10 m²
BATHROOM
6 m²
FOYER
NN
SHEET NUMBER:
DATE:
SCALE:
ARCHITECTURAL TECHNOLOGY AND SUSTAINABLE DESIGN
ARCH 3008
SANDRA SEBANEK 100859424
ANASTASIIA SKOROBOHACH 100857317
DILLON CLARKE 100766647
BOJAN KARANOVIC 100347529
SHEET NAME:
MARLENE SLOPACK
1 : 75
UNIT C
02/12/15
A104
1 : 75A104
GROUND FLOOR UNIT C - VARIETY STORE1
1 : 75A104
SECOND FLOOR UNIT C - 1 + DEN RESIDENTIAL2
30. 750 GARBAGE
CHUTE
ELECTR.
44 m²
COFFEE STORE
4 m²
VESTIBULE
10 m²
HALLWAY
10 m²
KITCHEN
6 m²
STORAGE
6 m²
GARBAGE ROOM
7 m²
FOYER
6 m²
MALE
WASHROOM
5 m²
FEMALE
WASHROOM
GARBAGE
CHUTE
WIC
STORAGE
11 m²
BALCONY
18 m²
LIV. ROOM
12 m²
HALLWAY
9 m²
KITCHEN
11 m²
BEDROOM
8 m²
BATHR.
8 m²
DEN
3 m²
LAUNDRY
4 m²
FOYER
NN
SHEET NUMBER:
DATE:
SCALE:
ARCHITECTURAL TECHNOLOGY AND SUSTAINABLE DESIGN
ARCH 3008
SANDRA SEBANEK 100859424
ANASTASIIA SKOROBOHACH 100857317
DILLON CLARKE 100766647
BOJAN KARANOVIC 100347529
SHEET NAME:
MARLENE SLOPACK
1 : 75
UNIT D
02/12/15
A105
1 : 75A105
GROUND FLOOR UNIT D1
1 : 75A105
SECOND FLOOR UNIT D - 1 + DEN RESIDENTIAL2
31. GROUND FLOOR
0
SECOND FLOOR
3000
ROOF
5500
TOP OF ROOF
8000
SHEET NUMBER:
DATE:
SCALE:
ARCHITECTURAL TECHNOLOGY AND SUSTAINABLE DESIGN
ARCH 3008
SANDRA SEBANEK 100859424
ANASTASIIA SKOROBOHACH 100857317
DILLON CLARKE 100766647
BOJAN KARANOVIC 100347529
SHEET NAME:
MARLENE SLOPACK
1 : 75
FRONT ELEVATION
02/12/15
A106
1 : 75A106
FRONT ELEVATION1
32. GROUND FLOOR
0
SECOND FLOOR
3000
ROOF
5500
TOP OF ROOF
8000
SHEET NUMBER:
DATE:
SCALE:
ARCHITECTURAL TECHNOLOGY AND SUSTAINABLE DESIGN
ARCH 3008
SANDRA SEBANEK 100859424
ANASTASIIA SKOROBOHACH 100857317
DILLON CLARKE 100766647
BOJAN KARANOVIC 100347529
SHEET NAME:
MARLENE SLOPACK
1 : 100
SOUTH SIDE ELEVATION
02/12/15
A107
1 : 100A107
EAST ELEVATION1
33. GROUND FLOOR
0
SECOND FLOOR
3000
ROOF
5500
TOP OF ROOF
8000
SHEET NUMBER:
DATE:
SCALE:
ARCHITECTURAL TECHNOLOGY AND SUSTAINABLE DESIGN
ARCH 3008
SANDRA SEBANEK 100859424
ANASTASIIA SKOROBOHACH 100857317
DILLON CLARKE 100766647
BOJAN KARANOVIC 100347529
SHEET NAME:
MARLENE SLOPACK
1 : 50
FRONT ELEVATION UNIT A
02/12/15
A108
1 : 50A108
FRONT ELEVATION UNIT A1
34. GROUND FLOOR
0
SECOND FLOOR
3000
ROOF
5500
TOP OF ROOF
8000
SHEET NUMBER:
DATE:
SCALE:
ARCHITECTURAL TECHNOLOGY AND SUSTAINABLE DESIGN
ARCH 3008
SANDRA SEBANEK 100859424
ANASTASIIA SKOROBOHACH 100857317
DILLON CLARKE 100766647
BOJAN KARANOVIC 100347529
SHEET NAME:
MARLENE SLOPACK
1 : 50
FRONT ELEVATION UNIT B
02/12/15
A109
1 : 50A109
FRONT ELEVATION UNIT B1
35. GROUND FLOOR
0
SECOND FLOOR
3000
ROOF
5500
TOP OF ROOF
8000
SHEET NUMBER:
DATE:
SCALE:
ARCHITECTURAL TECHNOLOGY AND SUSTAINABLE DESIGN
ARCH 3008
SANDRA SEBANEK 100859424
ANASTASIIA SKOROBOHACH 100857317
DILLON CLARKE 100766647
BOJAN KARANOVIC 100347529
SHEET NAME:
MARLENE SLOPACK
1 : 50
FRONT ELEVATION UNIT C
02/12/15
A110
1 : 50A110
FRONT ELEVATION UNIT C1
36. GROUND FLOOR
0
SECOND FLOOR
3000
ROOF
5500
TOP OF ROOF
8000
SHEET NUMBER:
DATE:
SCALE:
ARCHITECTURAL TECHNOLOGY AND SUSTAINABLE DESIGN
ARCH 3008
SANDRA SEBANEK 100859424
ANASTASIIA SKOROBOHACH 100857317
DILLON CLARKE 100766647
BOJAN KARANOVIC 100347529
SHEET NAME:
MARLENE SLOPACK
1 : 50
FRONT ELEVATION UNIT D
02/12/15
A111
1 : 50A111
FRONT ELEVATION UNIT D1