Project Data Sheet
E-33591 Villanueva de Pría (Asturias) Project ID: 2413
Passive House Days Attendance:
Building type: detached single family house (Passive House new build)
Project description: This building is a single family house split over two floors, with one green roof connected with the land plot
Prefabricated wood, external Wall Cork board Insulation, cellular glass insulation, polypropylene pipes and electrical
wiring, with an electrical installation biocompatible, landscape roof, lime plaster, solar energy, reuse of rainwater,
treatment of wastewater ...
Minimum gray energy of materials. Adapted to the European guidelines for low consumption 2012-2020. Monitoring
runs to see results.
Location: E-33591 Villanueva de Pría (Asturias)
'12
23/04/13 Passive House Buildings
www.passivhausprojekte.de/projekte.php?detail=2413&tdp=&print=2 2/4
Number of apartments / units: 1
Treated Floor Area according to PHPP: 131 m²
Construction type: timber construction
Exterior wall: Cross-Laminated Timber + Cork board Insulation (160mm)
95 mm Cross-Laminated Timber KLH
16 cm Cork board Insulation WLS 038
ventilated facades with wood cladding, limestone or silicated-based finished facades.
U-value = 0,2 W/(m²K)
Basement floor / floor slab: Concrete Slab with cellular glass insulation (100mm)
10 cm cellular glass insulation WLS 050
25 cm Concrete Slab
6cm Cork board Insulation WLS 038
U-value = 0,24 W/(m²K)
Roof: Cross-Laminated Timber + Cork board Insulation (160mm)+ Roof sarking board (22mm)
18,2 cm Cross-Laminated Timber KLH
16 cm Cork board Insulation WLS 038
2,2cm Roof sarking board
U-value = 0,19 W/(m²K)
Frame: Benito-Sdc, Ebania Elite
Wood frame Uf-value 1,3 W/(m²K), 68mm
Editor's note: Uf-/ Uw- values consider the specific climate data.
Uw -value = 1,27 W/(m²K)
Glazing: double glazing - due to the climate, 4-16-4 / low e, argon 90%
23/04/13 Passive House Buildings
www.passivhausprojekte.de/projekte.php?detail=2413&tdp=&print=2 3/4
Editor's note: Values consider the specific climate data.
Ug-value = 1,1 W/(m²K)
g-value = 58 %
Entrance door: insulated wooden door
Cork board Insulation
Ud-value = 0,76 W/(m²K)
Ventilation: Zehnder System, Zehnder, Comfoair 350
VMC Zendher Comfoair 350 Heat recovery rate
(specific, incl. distribution): 75 %
- rendement de 84% (Passiv Haus Institute)
Heating installation: Wolf SEM-1 500 Litros Steel solar tank with two plain tube heat exchangers + solar collectors 6,92 m²
Heating with supply air (water/air battery) and towelrads heating system.
Woodburning stovevitra passive house.
Domestic hot water: SHAPE PREMIUM water heater for Domestic Hot Water + solar collectors 6,92 m² + Wolf SEM-1 500 Litros Steel
solar tank with two plain tube heat exchangers
Air tightness: n50 = 0,4/h (press. test value)
Ecological aspects: 6,92m² solar collectors, ecological construction materials, rain water harvesting to garden, whaser and wc, treatment
of wastewater, landscape roof.
Annual heating demand: 12 kWh/(m²a) calculated according to PHPP
Heating load: 11 W/(m²) calculated according to PHPP
23/04/13 Passive House Buildings
www.passivhausprojekte.de/projekte.php?detail=2413&tdp=&print=2 4/4
Primary energy requirement: 104 kWh/(m²a) total demand on heating installation, domestic hot water, household electricity and auxiliary
electricity calculated according to PHPP
Construction costs (gross):
Building structure costs (gross):
Year of construction: 2012
Architecture: DUQUEYZAMORA arquitectos
Building services: DUQUEYZAMORA arquitectos
Building physics: M.Wassouf – Energiehaus
Statics:
Craftsperson / parties involved: M.Wassouf – Energiehaus I Certificate: PHI
Miscellaneous:
Other parties involved: Passivhaus Institut | 64283 Darmstadt | Zertifikat
Project database www.passivehouse-buildings.org | Last change: 12:30

Weitere ähnliche Inhalte

Was ist angesagt?

Passive Home Training Module for Architects and Planners
Passive Home Training Module for Architects and PlannersPassive Home Training Module for Architects and Planners
Passive Home Training Module for Architects and Planners
Leonardo ENERGY
 
Under Floor Heating Presentation
Under Floor Heating PresentationUnder Floor Heating Presentation
Under Floor Heating Presentation
Anil Kumar Tufchi
 
[Nordic GBC Conference 2013] Ville Reinikainen: Renewal of Meilahti Tower Hos...
[Nordic GBC Conference 2013] Ville Reinikainen: Renewal of Meilahti Tower Hos...[Nordic GBC Conference 2013] Ville Reinikainen: Renewal of Meilahti Tower Hos...
[Nordic GBC Conference 2013] Ville Reinikainen: Renewal of Meilahti Tower Hos...
GBC Finland
 
Presentation passive design strategies
Presentation passive design strategiesPresentation passive design strategies
Presentation passive design strategies
Cindy Lim
 
Options for energy_sustainability
Options for energy_sustainabilityOptions for energy_sustainability
Options for energy_sustainability
Julian Swindell
 

Was ist angesagt? (20)

Solar building design
Solar building designSolar building design
Solar building design
 
Solar.FIN®
Solar.FIN® Solar.FIN®
Solar.FIN®
 
Presentation
PresentationPresentation
Presentation
 
conservation of energy done by madagascar group
conservation of energy  done by madagascar groupconservation of energy  done by madagascar group
conservation of energy done by madagascar group
 
Passive Home Training Module for Architects and Planners
Passive Home Training Module for Architects and PlannersPassive Home Training Module for Architects and Planners
Passive Home Training Module for Architects and Planners
 
Renewable Heat/PassivHaus - Gary Wilburn, HPW
Renewable Heat/PassivHaus - Gary Wilburn, HPWRenewable Heat/PassivHaus - Gary Wilburn, HPW
Renewable Heat/PassivHaus - Gary Wilburn, HPW
 
Iaetsd sinter coolers
Iaetsd sinter coolersIaetsd sinter coolers
Iaetsd sinter coolers
 
Under Floor Heating Presentation
Under Floor Heating PresentationUnder Floor Heating Presentation
Under Floor Heating Presentation
 
[Nordic GBC Conference 2013] Ville Reinikainen: Renewal of Meilahti Tower Hos...
[Nordic GBC Conference 2013] Ville Reinikainen: Renewal of Meilahti Tower Hos...[Nordic GBC Conference 2013] Ville Reinikainen: Renewal of Meilahti Tower Hos...
[Nordic GBC Conference 2013] Ville Reinikainen: Renewal of Meilahti Tower Hos...
 
Technical challenges and solutions for the integration of low-grade heat sour...
Technical challenges and solutions for the integration of low-grade heat sour...Technical challenges and solutions for the integration of low-grade heat sour...
Technical challenges and solutions for the integration of low-grade heat sour...
 
Public space services - Temples
Public space services - TemplesPublic space services - Temples
Public space services - Temples
 
Natura realtyplus nomination
Natura realtyplus nominationNatura realtyplus nomination
Natura realtyplus nomination
 
Green Homes natura
Green Homes naturaGreen Homes natura
Green Homes natura
 
The eastgate centre, biomimicry architecture,
The eastgate centre, biomimicry architecture, The eastgate centre, biomimicry architecture,
The eastgate centre, biomimicry architecture,
 
GroupA_poster 2
GroupA_poster 2GroupA_poster 2
GroupA_poster 2
 
Presentation passive design strategies
Presentation passive design strategiesPresentation passive design strategies
Presentation passive design strategies
 
Options for energy_sustainability
Options for energy_sustainabilityOptions for energy_sustainability
Options for energy_sustainability
 
Passive cooling techniques in buildings
Passive cooling techniques in buildingsPassive cooling techniques in buildings
Passive cooling techniques in buildings
 
Nearly Zero Energy Exemplar Buildings
Nearly Zero Energy Exemplar BuildingsNearly Zero Energy Exemplar Buildings
Nearly Zero Energy Exemplar Buildings
 
Passive solar buildings.pptx arun
Passive solar buildings.pptx arunPassive solar buildings.pptx arun
Passive solar buildings.pptx arun
 

Andere mochten auch (10)

Śniadanie Daje Moc
Śniadanie Daje MocŚniadanie Daje Moc
Śniadanie Daje Moc
 
E-Learning Section-32
E-Learning Section-32E-Learning Section-32
E-Learning Section-32
 
Control contitucional
Control contitucionalControl contitucional
Control contitucional
 
E-Learning Section-24
E-Learning Section-24E-Learning Section-24
E-Learning Section-24
 
Sovak Resume 06.08.2016
Sovak Resume 06.08.2016Sovak Resume 06.08.2016
Sovak Resume 06.08.2016
 
Tea Time Training
Tea Time TrainingTea Time Training
Tea Time Training
 
ey Bermad Air Valves Brochure
ey Bermad Air Valves Brochureey Bermad Air Valves Brochure
ey Bermad Air Valves Brochure
 
E-Learning Section-4
E-Learning Section-4E-Learning Section-4
E-Learning Section-4
 
Results presentation q3 2016
Results presentation q3 2016Results presentation q3 2016
Results presentation q3 2016
 
Presentationzen cua cam thi thanh le
Presentationzen cua cam thi thanh lePresentationzen cua cam thi thanh le
Presentationzen cua cam thi thanh le
 

Ähnlich wie Passive house buildings

University guest house for visiting FINAL
University guest house for visiting FINALUniversity guest house for visiting FINAL
University guest house for visiting FINAL
Ilgar Manafsoy
 
BLDG 476 - HEAT TRANSFER
BLDG 476 - HEAT TRANSFERBLDG 476 - HEAT TRANSFER
BLDG 476 - HEAT TRANSFER
Rupali Patel
 
Energy saving in green building
Energy saving in green buildingEnergy saving in green building
Energy saving in green building
akshaykathalkar
 
Report about start-up of the Plant Sublidecor 700 double panel wall 1x10
Report about start-up of the Plant Sublidecor 700 double panel wall 1x10Report about start-up of the Plant Sublidecor 700 double panel wall 1x10
Report about start-up of the Plant Sublidecor 700 double panel wall 1x10
George Vamvakousis
 

Ähnlich wie Passive house buildings (20)

University guest house for visiting FINAL
University guest house for visiting FINALUniversity guest house for visiting FINAL
University guest house for visiting FINAL
 
Passive House: concept and application for dwellings
Passive House: concept and application for dwellingsPassive House: concept and application for dwellings
Passive House: concept and application for dwellings
 
Leisure Center. Part 2
Leisure Center. Part 2Leisure Center. Part 2
Leisure Center. Part 2
 
'CASE STUDY OF INDIRA PARYAVARAN BHAVAN DELHI ,
'CASE STUDY OF INDIRA PARYAVARAN BHAVAN DELHI ,'CASE STUDY OF INDIRA PARYAVARAN BHAVAN DELHI ,
'CASE STUDY OF INDIRA PARYAVARAN BHAVAN DELHI ,
 
case study enviroment
case study enviromentcase study enviroment
case study enviroment
 
04cB3 study PLEA2004.pdf
04cB3 study PLEA2004.pdf04cB3 study PLEA2004.pdf
04cB3 study PLEA2004.pdf
 
BLDG 476 - HEAT TRANSFER
BLDG 476 - HEAT TRANSFERBLDG 476 - HEAT TRANSFER
BLDG 476 - HEAT TRANSFER
 
Indira paryavaran bhawan
 Indira paryavaran bhawan Indira paryavaran bhawan
Indira paryavaran bhawan
 
A2_Boonstra
A2_BoonstraA2_Boonstra
A2_Boonstra
 
Questioni di facciata 2015 | Roberto Lollini (EURAC)
Questioni di facciata 2015 | Roberto Lollini (EURAC)Questioni di facciata 2015 | Roberto Lollini (EURAC)
Questioni di facciata 2015 | Roberto Lollini (EURAC)
 
Energy saving in green building
Energy saving in green buildingEnergy saving in green building
Energy saving in green building
 
Coatleven en
Coatleven   enCoatleven   en
Coatleven en
 
Energy saving in green building
Energy saving in green buildingEnergy saving in green building
Energy saving in green building
 
Energy Modelling comparison project
Energy Modelling comparison projectEnergy Modelling comparison project
Energy Modelling comparison project
 
Building an even better Passivhaus School
Building an even better Passivhaus SchoolBuilding an even better Passivhaus School
Building an even better Passivhaus School
 
Installations Brochure Ecoforest Heat Pumps
Installations Brochure Ecoforest Heat PumpsInstallations Brochure Ecoforest Heat Pumps
Installations Brochure Ecoforest Heat Pumps
 
Energy Efficiency Awards - Brussels April 12th
Energy Efficiency Awards - Brussels April 12thEnergy Efficiency Awards - Brussels April 12th
Energy Efficiency Awards - Brussels April 12th
 
Report about start-up of the Plant Sublidecor 700 double panel wall 1x10
Report about start-up of the Plant Sublidecor 700 double panel wall 1x10Report about start-up of the Plant Sublidecor 700 double panel wall 1x10
Report about start-up of the Plant Sublidecor 700 double panel wall 1x10
 
Presentation energy and comfort
Presentation  energy and comfort Presentation  energy and comfort
Presentation energy and comfort
 
Green house
Green houseGreen house
Green house
 

Mehr von Carmen Delgado Martin

Ecología y arquitura_Estilos de Vida_La Vanguardia 7 junio-14
Ecología y arquitura_Estilos de Vida_La Vanguardia 7 junio-14Ecología y arquitura_Estilos de Vida_La Vanguardia 7 junio-14
Ecología y arquitura_Estilos de Vida_La Vanguardia 7 junio-14
Carmen Delgado Martin
 
Impactos, vulnerabilidad y adaptación al cambio climático. el caso del litora...
Impactos, vulnerabilidad y adaptación al cambio climático. el caso del litora...Impactos, vulnerabilidad y adaptación al cambio climático. el caso del litora...
Impactos, vulnerabilidad y adaptación al cambio climático. el caso del litora...
Carmen Delgado Martin
 
Municipal climate protection_position_paper_phi (1)
Municipal climate protection_position_paper_phi (1)Municipal climate protection_position_paper_phi (1)
Municipal climate protection_position_paper_phi (1)
Carmen Delgado Martin
 
Lvg 15 12-13-_llega la ventilacion inteligente
Lvg 15 12-13-_llega la ventilacion inteligenteLvg 15 12-13-_llega la ventilacion inteligente
Lvg 15 12-13-_llega la ventilacion inteligente
Carmen Delgado Martin
 

Mehr von Carmen Delgado Martin (20)

FICHA RECOGIDA DE DATOS Y GRATIFICA CO2
FICHA RECOGIDA DE DATOS Y GRATIFICA CO2 FICHA RECOGIDA DE DATOS Y GRATIFICA CO2
FICHA RECOGIDA DE DATOS Y GRATIFICA CO2
 
Desayuno tecnológico 14 noviembre
Desayuno tecnológico 14 noviembreDesayuno tecnológico 14 noviembre
Desayuno tecnológico 14 noviembre
 
11th Passivhaus Days 2014_casa entre_encinas
11th Passivhaus Days 2014_casa entre_encinas11th Passivhaus Days 2014_casa entre_encinas
11th Passivhaus Days 2014_casa entre_encinas
 
Programa definitivo jORNADA ASEM FIDMA_14
Programa definitivo jORNADA ASEM FIDMA_14Programa definitivo jORNADA ASEM FIDMA_14
Programa definitivo jORNADA ASEM FIDMA_14
 
Belleza ecológica_Es La Vanguardia_7_junio_14
Belleza ecológica_Es La Vanguardia_7_junio_14Belleza ecológica_Es La Vanguardia_7_junio_14
Belleza ecológica_Es La Vanguardia_7_junio_14
 
Ecología y arquitura_Estilos de Vida_La Vanguardia 7 junio-14
Ecología y arquitura_Estilos de Vida_La Vanguardia 7 junio-14Ecología y arquitura_Estilos de Vida_La Vanguardia 7 junio-14
Ecología y arquitura_Estilos de Vida_La Vanguardia 7 junio-14
 
Impactos, vulnerabilidad y adaptación al cambio climático. el caso del litora...
Impactos, vulnerabilidad y adaptación al cambio climático. el caso del litora...Impactos, vulnerabilidad y adaptación al cambio climático. el caso del litora...
Impactos, vulnerabilidad y adaptación al cambio climático. el caso del litora...
 
Biohaus entreencinas en nueva york
Biohaus entreencinas en nueva yorkBiohaus entreencinas en nueva york
Biohaus entreencinas en nueva york
 
Pagina 17 ph brochure_2014
Pagina 17 ph brochure_2014Pagina 17 ph brochure_2014
Pagina 17 ph brochure_2014
 
Reglamento ue mercurio abril14
Reglamento ue mercurio abril14Reglamento ue mercurio abril14
Reglamento ue mercurio abril14
 
Municipal climate protection_position_paper_phi (1)
Municipal climate protection_position_paper_phi (1)Municipal climate protection_position_paper_phi (1)
Municipal climate protection_position_paper_phi (1)
 
Notainformativa sgae-mfom
Notainformativa sgae-mfomNotainformativa sgae-mfom
Notainformativa sgae-mfom
 
2014 03 03_new_passive_house_categories_press_release
2014 03 03_new_passive_house_categories_press_release2014 03 03_new_passive_house_categories_press_release
2014 03 03_new_passive_house_categories_press_release
 
Perfora chico perfora_ J. David Hughes
Perfora chico perfora_  J. David Hughes Perfora chico perfora_  J. David Hughes
Perfora chico perfora_ J. David Hughes
 
Lvg 15 12-13-_llega la ventilacion inteligente
Lvg 15 12-13-_llega la ventilacion inteligenteLvg 15 12-13-_llega la ventilacion inteligente
Lvg 15 12-13-_llega la ventilacion inteligente
 
Conclusiones workshosp-eecn-2013
Conclusiones workshosp-eecn-2013Conclusiones workshosp-eecn-2013
Conclusiones workshosp-eecn-2013
 
Jornada pep valladolid enero
Jornada pep valladolid eneroJornada pep valladolid enero
Jornada pep valladolid enero
 
2013 12 17_passive_house_conference_programme_press_release
2013 12 17_passive_house_conference_programme_press_release2013 12 17_passive_house_conference_programme_press_release
2013 12 17_passive_house_conference_programme_press_release
 
International passive house_conference_2014_aachen_flyer
International passive house_conference_2014_aachen_flyerInternational passive house_conference_2014_aachen_flyer
International passive house_conference_2014_aachen_flyer
 
20131213 indice-global-energy-architecture
20131213 indice-global-energy-architecture20131213 indice-global-energy-architecture
20131213 indice-global-energy-architecture
 

Passive house buildings

  • 1. 23/04/13 Passive House Buildings www.passivhausprojekte.de/projekte.php?detail=2413&tdp=&print=2 1/4 Project Data Sheet E-33591 Villanueva de Pría (Asturias) Project ID: 2413 Passive House Days Attendance: Building type: detached single family house (Passive House new build) Project description: This building is a single family house split over two floors, with one green roof connected with the land plot Prefabricated wood, external Wall Cork board Insulation, cellular glass insulation, polypropylene pipes and electrical wiring, with an electrical installation biocompatible, landscape roof, lime plaster, solar energy, reuse of rainwater, treatment of wastewater ... Minimum gray energy of materials. Adapted to the European guidelines for low consumption 2012-2020. Monitoring runs to see results. Location: E-33591 Villanueva de Pría (Asturias) '12
  • 2. 23/04/13 Passive House Buildings www.passivhausprojekte.de/projekte.php?detail=2413&tdp=&print=2 2/4 Number of apartments / units: 1 Treated Floor Area according to PHPP: 131 m² Construction type: timber construction Exterior wall: Cross-Laminated Timber + Cork board Insulation (160mm) 95 mm Cross-Laminated Timber KLH 16 cm Cork board Insulation WLS 038 ventilated facades with wood cladding, limestone or silicated-based finished facades. U-value = 0,2 W/(m²K) Basement floor / floor slab: Concrete Slab with cellular glass insulation (100mm) 10 cm cellular glass insulation WLS 050 25 cm Concrete Slab 6cm Cork board Insulation WLS 038 U-value = 0,24 W/(m²K) Roof: Cross-Laminated Timber + Cork board Insulation (160mm)+ Roof sarking board (22mm) 18,2 cm Cross-Laminated Timber KLH 16 cm Cork board Insulation WLS 038 2,2cm Roof sarking board U-value = 0,19 W/(m²K) Frame: Benito-Sdc, Ebania Elite Wood frame Uf-value 1,3 W/(m²K), 68mm Editor's note: Uf-/ Uw- values consider the specific climate data. Uw -value = 1,27 W/(m²K) Glazing: double glazing - due to the climate, 4-16-4 / low e, argon 90%
  • 3. 23/04/13 Passive House Buildings www.passivhausprojekte.de/projekte.php?detail=2413&tdp=&print=2 3/4 Editor's note: Values consider the specific climate data. Ug-value = 1,1 W/(m²K) g-value = 58 % Entrance door: insulated wooden door Cork board Insulation Ud-value = 0,76 W/(m²K) Ventilation: Zehnder System, Zehnder, Comfoair 350 VMC Zendher Comfoair 350 Heat recovery rate (specific, incl. distribution): 75 % - rendement de 84% (Passiv Haus Institute) Heating installation: Wolf SEM-1 500 Litros Steel solar tank with two plain tube heat exchangers + solar collectors 6,92 m² Heating with supply air (water/air battery) and towelrads heating system. Woodburning stovevitra passive house. Domestic hot water: SHAPE PREMIUM water heater for Domestic Hot Water + solar collectors 6,92 m² + Wolf SEM-1 500 Litros Steel solar tank with two plain tube heat exchangers Air tightness: n50 = 0,4/h (press. test value) Ecological aspects: 6,92m² solar collectors, ecological construction materials, rain water harvesting to garden, whaser and wc, treatment of wastewater, landscape roof. Annual heating demand: 12 kWh/(m²a) calculated according to PHPP Heating load: 11 W/(m²) calculated according to PHPP
  • 4. 23/04/13 Passive House Buildings www.passivhausprojekte.de/projekte.php?detail=2413&tdp=&print=2 4/4 Primary energy requirement: 104 kWh/(m²a) total demand on heating installation, domestic hot water, household electricity and auxiliary electricity calculated according to PHPP Construction costs (gross): Building structure costs (gross): Year of construction: 2012 Architecture: DUQUEYZAMORA arquitectos Building services: DUQUEYZAMORA arquitectos Building physics: M.Wassouf – Energiehaus Statics: Craftsperson / parties involved: M.Wassouf – Energiehaus I Certificate: PHI Miscellaneous: Other parties involved: Passivhaus Institut | 64283 Darmstadt | Zertifikat Project database www.passivehouse-buildings.org | Last change: 12:30