1. 23/04/13 Passive House Buildings
www.passivhausprojekte.de/projekte.php?detail=2413&tdp=&print=2 1/4
Project Data Sheet
E-33591 Villanueva de Pría (Asturias) Project ID: 2413
Passive House Days Attendance:
Building type: detached single family house (Passive House new build)
Project description: This building is a single family house split over two floors, with one green roof connected with the land plot
Prefabricated wood, external Wall Cork board Insulation, cellular glass insulation, polypropylene pipes and electrical
wiring, with an electrical installation biocompatible, landscape roof, lime plaster, solar energy, reuse of rainwater,
treatment of wastewater ...
Minimum gray energy of materials. Adapted to the European guidelines for low consumption 2012-2020. Monitoring
runs to see results.
Location: E-33591 Villanueva de Pría (Asturias)
'12
2. 23/04/13 Passive House Buildings
www.passivhausprojekte.de/projekte.php?detail=2413&tdp=&print=2 2/4
Number of apartments / units: 1
Treated Floor Area according to PHPP: 131 m²
Construction type: timber construction
Exterior wall: Cross-Laminated Timber + Cork board Insulation (160mm)
95 mm Cross-Laminated Timber KLH
16 cm Cork board Insulation WLS 038
ventilated facades with wood cladding, limestone or silicated-based finished facades.
U-value = 0,2 W/(m²K)
Basement floor / floor slab: Concrete Slab with cellular glass insulation (100mm)
10 cm cellular glass insulation WLS 050
25 cm Concrete Slab
6cm Cork board Insulation WLS 038
U-value = 0,24 W/(m²K)
Roof: Cross-Laminated Timber + Cork board Insulation (160mm)+ Roof sarking board (22mm)
18,2 cm Cross-Laminated Timber KLH
16 cm Cork board Insulation WLS 038
2,2cm Roof sarking board
U-value = 0,19 W/(m²K)
Frame: Benito-Sdc, Ebania Elite
Wood frame Uf-value 1,3 W/(m²K), 68mm
Editor's note: Uf-/ Uw- values consider the specific climate data.
Uw -value = 1,27 W/(m²K)
Glazing: double glazing - due to the climate, 4-16-4 / low e, argon 90%
3. 23/04/13 Passive House Buildings
www.passivhausprojekte.de/projekte.php?detail=2413&tdp=&print=2 3/4
Editor's note: Values consider the specific climate data.
Ug-value = 1,1 W/(m²K)
g-value = 58 %
Entrance door: insulated wooden door
Cork board Insulation
Ud-value = 0,76 W/(m²K)
Ventilation: Zehnder System, Zehnder, Comfoair 350
VMC Zendher Comfoair 350 Heat recovery rate
(specific, incl. distribution): 75 %
- rendement de 84% (Passiv Haus Institute)
Heating installation: Wolf SEM-1 500 Litros Steel solar tank with two plain tube heat exchangers + solar collectors 6,92 m²
Heating with supply air (water/air battery) and towelrads heating system.
Woodburning stovevitra passive house.
Domestic hot water: SHAPE PREMIUM water heater for Domestic Hot Water + solar collectors 6,92 m² + Wolf SEM-1 500 Litros Steel
solar tank with two plain tube heat exchangers
Air tightness: n50 = 0,4/h (press. test value)
Ecological aspects: 6,92m² solar collectors, ecological construction materials, rain water harvesting to garden, whaser and wc, treatment
of wastewater, landscape roof.
Annual heating demand: 12 kWh/(m²a) calculated according to PHPP
Heating load: 11 W/(m²) calculated according to PHPP
4. 23/04/13 Passive House Buildings
www.passivhausprojekte.de/projekte.php?detail=2413&tdp=&print=2 4/4
Primary energy requirement: 104 kWh/(m²a) total demand on heating installation, domestic hot water, household electricity and auxiliary
electricity calculated according to PHPP
Construction costs (gross):
Building structure costs (gross):
Year of construction: 2012
Architecture: DUQUEYZAMORA arquitectos
Building services: DUQUEYZAMORA arquitectos
Building physics: M.Wassouf – Energiehaus
Statics:
Craftsperson / parties involved: M.Wassouf – Energiehaus I Certificate: PHI
Miscellaneous:
Other parties involved: Passivhaus Institut | 64283 Darmstadt | Zertifikat
Project database www.passivehouse-buildings.org | Last change: 12:30