The document summarizes a study that investigated how the photoluminescence quantum yield of lead selenide quantum dots is affected by increasing excitation energy. Three samples of PbSe quantum dots were synthesized with different diameters and characterized. It was found that the quantum yield decreased as the excitation energy increased, likely due to the formation of multi-exciton states within single quantum dots that lead to non-radiative Auger processes. The quantum yield was measured using an integrating sphere method and by analyzing absorption and emission spectra of the samples excited at different wavelengths. The results supported the expectation that higher excitation energies reduce quantum yield.
2. 1
Table of Contents
Table of Contents 1
Abstract 2
Introduction 2
Experimental 6
Data Treatment 10
Results & Discussion 13
Conclusion 19
Bibliography 19
3. 2
Abstract:
Three samples of colloidal lead-selenide quantum dots (QDs) were synthesized and
characterized by transmission electron microscopy (TEM), absorption spectroscopy, and
photoluminescence spectroscopy. The values obtained from these characterized samples were
used to design a study to determine if the photoluminescence quantum yield of the synthesized
samples decreased as the excitation wavelength used to trigger emission from the sample
increased in energy on the high energy side of the absorbance exciton. It was determined that the
photoluminescence quantum yield decreased as the excitation energy increased in energy likely
due to the formation of multi-exciton states within single quantum dots resulting in non-radiative
Auger processes.
Introduction:
The field of nanotechnology is already widely applied within technology and current
scientific research, and has plenty of opportunity for further advancement as more is learned as
scientists delve deeper into the depths of the unseen. Semiconducting materials are a major area
of study within materials chemistry, one subtopic of this area in particular, has crossed paths
with the fast-evolving field of nanotechnology. Quantum dots are a fairly recent addition to the
field of semiconducting materials, and are named as such due to their physical properties being
well described by quantum mechanical theory. The requirements for a material to be classified as
a semiconductor are related to the band gap of the material. The band gap is the distance in
energy between the valence band, or highest occupied energy band of the material, and the
conduction band, or lowest unoccupied energy level of the material. A band gap occurs when
there is a gap of energies where there are no molecular orbitals. In other words, there are no
4. 3
quantum mechanical states allowed within the energy range of the band gap. Many physical
properties of materials are dependent upon the size of their band gap.1
The relative sizes of band
gaps for insulators, semiconductors, and metals is shown in figure 1 below.
Figure 1. Relative band gap energies (Eg) of insulators, semiconductors, and metals
Quantum dots are essentially tiny little particles of semiconducting material that exhibit
interesting and useful physical and optical properties due to their increased surface area to
volume ratio as compared to bulk semiconducting materials. They have several applications
within the realms of bio-imaging2
, quantum computing3
, spintronics4
, and photovoltaic devices.5
One of their more notable characteristics is their ability to emit light, or, in other words, their
photoluminescence. Their small volumes increase the efficiency in which they emit light relative
to bulk semiconductors because a bulk semiconductor has more volume to allow for faster
energy dispersal resulting in non-radiative processes.6
The high efficiency photoluminescence of
quantum dots is also in part due to their band gap structure in regards to the positioning of the
conduction and valence bands in momentum space. Increased efficiency is seen with a direct
5. 4
band gap, in which the conduction band and valence band are positioned at the same value of
momentum, given by the directional wave-vector k, in momentum space.7
Figure 2. Optical transition of direct and indirect band gaps in momentum (k)-space
Not only are quantum dots efficient light emitters, their optical properties are
customizable and highly dependent upon their diameter.2
The customizable optical properties of
quantum dots are best described by the quantum confinement effect which applies to pieces of
semiconducting material having a radius under 10nm. The equation of the band gap energy of a
quantum dot is derived using the particle-in-a-sphere model application of the quantum
confinement effect to give the equation8
:
(1)
Where Eg,0 is the band gap energy of the bulk semiconductor made of the same material as the
quantum dot, meh is the average effective mass of the electron and the electron hole(these
concepts will be described in a following paragraph), R is the radius of the quantum dot, and is
6. 5
the reduced form of Planck’s constant divided by 2 . The only non-constant parameter in the band
gap equation is the radius of the quantum dot, giving the proportionality:
(2)
This proportionality shows that as the radius of a quantum dot decreases, the band gap energy
increases. This concept will be used in combination with the mechanism of emission to explain
the radial size effects on the optical properties of quantum dots.
When a quantum dot is excited with a photon, an electron is promoted from the valence
band to the conduction band, but when the electron leaves its valence band, it leaves an open
“hole” in the quantum state that the electron previously existed in. The two states are often called
an “electron-hole pair.” When the electron and the electron hole are in close proximity to one
another in space, they form a bound state known as an exciton due to the Coulombic interactions
between their opposing charges. The recombination of the two states often results in the emission
of a single photon, similar to the emission of a photon by a single atom. A quantum dot has
energy states that are often described using spherical quantum numbers with a subscript that
denotes whether the energy state is a hole or an electron.8
Figure 3. The defined energy states, S, P, and D, of a quantum dot within the valence band,
containing electrons and conduction band, containing electron holes
7. 6
An absorption maximum is seen at the 1ShSe optically allowed transition, suggesting that
the most efficient conversion of absorbed light into emitted light may occur at this energy. The
correct term for this conversion is the quantum yield, given by the formula9
:
( ) (3)
It is expected that as the excitation source light increases in energy relative to the absorption
maximum, the quantum yield will decrease due to an increased likelihood of non-radiative decay
processes, such as Auger processes.10
The quantum dots synthesized and used to determine the validity of this expectation are
colloidal lead-selenide (PbSe) quantum dots with oleic acid as a surfactant ligand layer making
the semiconductor core of PbSe dispersible in several solvents including tetrachloroethylene,
hexanes, and chloroform. These quantum dots are termed “colloidal” because the inorganic
semiconducting core is surrounded by an organic surfactant layer, much like a colloid.11
Colloidal quantum dots are a very practical type of nanoparticle to use in regards to the cost of
their synthesis, their relatively high quantum yields, and their photostability at room
temperature.12
Experimental:
Synthesis of PbSe Quantum dots with an Oleate Surfactant Layer:
The synthesis to make colloidal PbSe quantum dots was first reported by Murray et al.
The synthesis used to make the PbSe quantum dots required for the research explained in this
thesis was adapted from the Murray synthesis.11
0.4M Selenium in trioctylphosphine (TOP-Se)
was first prepared by dissolving selenium in TOP with heat and stirring inside of a nitrogen
8. 7
atmosphere glove box. A solution of lead oleate in 1-octadecene was then prepared by adding
~0.45g of lead(II) oxide and 1.3mL of oleic acid into 30mL of 1-octadecene. The lead oleate
solution was heated to 130o
C under vacuum , and kept under vacuum for 1.5 hours while stirring
to dissolve the lead oleate and remove water from the reaction flask.
Figure 4. Reaction set up for synthesis of colloidal PbSe quantum dots
Subsequently, the vacuum was turned off and the reaction flask was flushed with argon. The
temperature was changed to the preferred setting (see table 1 for reaction temperatures used).
Once the temperature equilibrated, 5mL of TOP-Se was obtained from the glove box and
injected into the reaction mixture with vigorous stirring. After the preferred reaction time, the
reaction was quickly quenched in 130mL of cold ethanol (~0-4o
C) for 1.5 minutes. This
quenching step is also the precipitation step. The quantum dots were washed four times with
fresh ethanol each time. The wash method was centrifugation at 1717RCF for 5 minutes per
wash. After the final wash, the ethanol was removed and the quantum dots were dried using
9. 8
argon gas and dispersed in tetrachloroethylene for storage/characterization. The quantum dots are
also dispersible in hexanes and chloroform. The samples were stored in an inert atmosphere by
bubbling with argon and sealing the vials with Teflon tape.
Table 1. Reaction conditions of characterized samples
Sample Temperature
/o
C
Reaction Time
/min
Approximate*
Particle Size
/nm
Absorbance
Maximum /nm
A 130 2 3.0 1217
B 135 3 3.6 1334
C 140 3 5.0 1438
*Sizes are approximate due to the state of the transmission electron microscope (TEM) when the
images were taken. The images are not up to par with the normal standard of clarity.
Measurement of Photoluminescence Quantum Yield using the Integrating Sphere Method:
An adapted method of measuring quantum yield using an integrating sphere was used to
produce the photoluminescence quantum yield values observed in this thesis.13
An integrating
sphere is a spherical sample chamber in which the sample is positioned in the center of the
sphere. The sphere’s interior walls are a reflective white surface, and there is an entrance hole for
the excitation source and an exit hole for light to hit the detector. A baffle was used to block
directly scattered light from entering the detector. First, a scan of pure solvent, in this case TCE,
was taken from 15nm on either side of the excitation wavelength. The scan was repeated 3 times
additively in order to achieve a high signal to noise ratio. The same scan was repeated with the
sample dispersed in TCE in order to calculate the difference in the amount of excitation light
absorbed by the sample from the amount of light absorbed by TCE. Subsequently, an emission
10. 9
scan of the sample was taken with at least 50nm on either side of the emission to give a decent
baseline reading. This scan was repeated additively depending on how strong the emission was
from the sample. Typically, emissions seen from the samples inside of the integration sphere
were weak due to lost intensity from the number of reflections made in the sphere before hitting
the detector. The method of quantum yield measurement was previously calibrated by another
member within the research group using quinine bisulfate.14
The excitation light source used was
an Edinburgh Instruments Xe900 xenon lamp paired with a TM300 monochromator of the same
brand. A UC900 sample chamber also made by Edinburgh Instruments was used and the detector
was a Hamamatsu R5509 PMT detector with a detection range of 700-1700nm. F900 software
made by Edinburgh Instruments was used to record the spectra obtained for quantum yield
measurements as well as emission spectra for each sample.
Figure 5. Schematic diagram of the integrating sphere used to measure the photoluminescence
quantum yield.
11. 10
Data Treatment:
In order to calculate the quantum yield for each sample, a number of steps were followed
to obtain an accurate quantum yield measurement. Since the number of photons absorbed or
emitted needs to be measured in energy, the wavelength axis of each spectrum was converted
into wavenumbers with the units m-1
.
Figure 6. Example conversion of emission spectrum of sample B to energy units. This
conversion was completed using the same method for all spectra used to calculate quantum yield.
The high peaks seen at the low energy side of the spectra are due to the Xe lamp correction file.
Once converted into energy units, the area under the curve in each spectra was obtained and used
as the amount of light absorbed or emitted respectively to the type of spectra being integrated.
In some of the spectra, higher order artifact signals of the excitation light, Xe lamp, from
the monochromator grating were seen in some of the signals (see figure 7). In this case, a line
was drawn across the artifact to connect either side of the emission curve, and the area under the
xenon artifact was calculated and subtracted from the total area under the curve. This does not
have a significant effect, if any at all, on the quantum yield as these artifacts were close to the
edges of the emission spectra where the emission curves approached the baseline.
12. 11
Figure 7. Example of artifacts seen in the emission spectrum of sample A excited at 756nm
The xenon lamp used as the excitation source for the quantum yield measurements and
the emission spectra of all of the samples has an intensity profile that decreases on either end of
the monochromator range due to the grating of the monochromator. A correction file is used to
correct for this profile, and the effects of the correction file are seen in the emission spectra
around 1600nm or 630000m-1
(see figure 5). For sample C, which emits at 1485nm, the low
energy side of the emission spectra is interfered with by the correction file. For all of the
absorption and emission spectra of sample A, B, and C, the curves are Gaussian in shape, and the
emission and absorption spectra are extremely similar in shape. Due to this extreme similarity,
the portion of the emission spectrum that was affected by the xenon lamp correction file was
drawn in to replicate the shape of the absorption spectra low energy side. The accuracy of the
quantum yield calculated from these corrected spectra was not significantly affected since the
correction file interference was on the edge of the emission spectra where the curve approached
the baseline.
13. 12
600000 650000 700000 750000 800000 850000
-2000
0
2000
4000
6000
8000
Intensity/a.u.
Wavenumber /m
-1
Figure 8. Example removal of correction file interference from 600000m-1
to 625000m-1
for
sample C emission curve with an 836nm excitation source
Once all of the spectra generated to calculate quantum yields were properly converted to
the energy scale and corrected by methods discussed above, the area’s under the curve were
taken and equilibrated by dividing by the number of additive scans completed for each sample
emission and source light spectra. The equilibrated values were then used to calculate the
quantum yield for each sample measurement. An example of the non-equilibrated and
equilibrated values is shown in table 2 below.
14. 13
Table 2. Example conversion of non-equilibrated peak areas to equilibrated values for sample B
excited at 1175nm
Spectrum Type: Pure TCE at
Excitation
Wavelength
PbSe Quantum Dots
in TCE at Excitation
Wavelength
Emission scan from
1000-1650nm
Number of Additive
Scans:
3 3 5
Area Under Non-
Equilibrated Curve:
/arbitrary units
2.82x109
2.66x109
1.03x108
Area Under
Equilibrated Curve:
/arbitrary units
9.40x108
8.88x108
2.06x107
Results & Discussion:
Three lead selenide colloidal quantum dot samples were synthesized with oleate used as
the surfactant for dispersal in various organic solvents. The aim was to make three PbSe quantum
dot samples evenly spaced in their absorption/emission peaks with relatively low dispersity.
Once synthesized, transmission electron microscope (TEM) images were taken using a JEOL
JEM-1400 TEM by a grad student within the research group.14
15. 14
(a) (b)
(c) (d)
(e) (f)
Figure 9. TEM images of: sample A at (a) 300K magnification and (b) 600K magnification,
Sample B at (c) 200K magnification and (d) 300K magnification, and Sample C at (e)300K
magnification and (f) 600K magnification.
16. 15
The TEM images obtained were not up to the usual standard quality due to the current working
state of the instrument. If the images were up to par, the edges of each quantum dot would be
more defined and the background of the images would not appear to be so spotted. Due to the
low quality of the images, the diameters of each sample characterized were deemed approximate,
and the dispersity of the samples was not reported. The approximate sizes were provided to
exemplify the effect of a decreasing radius on the absorption and emission maxima of a quantum
dot, but they were not relatively important to the purpose of the quantum yield study with varied
excitation energies. As discussed in the introduction, the absorbance and emission energies as the
radius of the samples decreased resulted in higher energy absorption and emission, following the
proportionality posed in equation (2).
Before determining the quantum yield of each sample, the absorption and emission
spectra were taken in preparation of the quantum yield measurements.
400 600 800 1000 1200 1400 1600
-0.2
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
Absorbance
Emission
Absorbance&Emission/a.u.
Wavelength /nm
(a) (b)
400 600 800 1000 1200 1400 1600
0.0
0.2
0.4
0.6
0.8
1.0
Absorbance
Emission
Absorbance&Emission/a.u.
Wavelength /nm
17. 16
400 600 800 1000 1200 1400 1600
-0.2
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
Absorbance
Emission
Absorbance&Emission/a.u.
Wavelength /nm
(c)
Figure 10. Absorbance and emission spectra of (a) sample A, (b) sample B, and (c) sample C
Once all of the absorption and emission maxima were determined, excitation wavelengths for
each sample were determined using equal energy values from each samples respective
absorbance maximum.
Table 3. Determined excitation wavelengths for quantum yield measurements at three different
energy values higher in energy than the absorption maximum of each sample.
Sample Absorption
Maximum
/nm
Emission
Maximum
/nm
Excitation
Wavelength
at
E1=79keV
/nm
Excitation
Wavelength
at
E2=158keV
/nm
Excitation
Wavelength
at
E3=390keV
/nm
A 1217 1270 1083 976 756
B 1334 1380 1175 1050 800
C 1438 1485 1255 1113 836
18. 17
The excitation energies determined for the quantum yield measurements were determined at
equal energy distances rather than equal wavelength distances because equal wavelength
distances at different positions on the electromagnetic spectrum are not equal in energy.
Excitation at exactly the absorption maximum for each sample was not taken due to the Gaussian
shape of emission spectra and interference that would have occurred with the emission curve and
excitation wavelength. The emissions observed occur at a slightly lower energy than the
absorption maxima due to the relaxation of the band structure via Coulombic interactions
between the electron and its paired electron hole.10
The photoluminescence quantum yield was determined for each sample at each energy
distance from the absorbance maximum using the quantum yield measurement method
previously discussed in the experimental section.
830000 835000 840000 845000 850000 855000 860000 865000 870000
0
200000
400000
600000
800000
PbSe QDs in TCE
Pure TCE
Intensity/a.u.
Wavenumber /m
-1
600000 650000 700000 750000 800000 850000
-2000
0
2000
4000
6000
8000
10000
12000
14000
16000
18000
Intensity/a.u.
Wavenumber /m
-1
(a) (b)
Figure 11. Sample plots of (a) 1175nm excitation light of sample B pure TCE measurement and
PbSe quantum dots in TCE and (b) emission spectrum of sample B excited at 1175nm. Both
plots have been converted into the wavenumber energy scale for quantum yield determination.
19. 18
Table 4.Determined photoluminescence quantum yields at E1, E2, and E3 for samples A, B,
and C
Sample Quantum Yield at
E1 /%
Quantum Yield at
E2 /%
Quantum Yield at
E3 /%
A 19 12 4.8
B 40 13 3.5
C (Trial 1) 20 11 1.5
C (Trial 2)* 14 9.6 1.4
C (Average) 17+/-4 10+/-1 1.4+/-0.1
*A second trial was conducted at a later date to see if the results were reproducible.
A common trend of decreased quantum yield was observed as the excitation wavelength
increased in energy and energy distance from the absorbance maximum. To give reason to the
decreasing quantum yield trend, one must consider what effects a higher energy excitation would
have on an excited quantum dot. Firstly, excitation by energies greater than twice the band gap
can result in bi- or multi-exciton formation.6
Multi-exciton formation is an occurrence when
more than one electron-hole pair is formed on a single quantum dot.12
In the case when a multi-
exciton is formed, the likelihood of non-radiative decay via the Auger process is increased. The
Auger process is when an electron is ejected from an outer energy level of a semiconducting
material. In atom-like systems of semiconductors such as quantum dots, electron-electron
coupling is larger than electron-photon coupling, which results in an increased rate for Auger
processes. The mechanism of the Auger process is believed to be a 4 particle process with the
involvement of a phonon.10
The Auger process has been proved to occur at a faster rate in atom-
like semiconducting materials, suggesting that the rate of Auger processes is size dependent.10
This may also give reasoning to varying quantum yield values for quantum dots excited at the
same energy distances from their absorption maxima. The main reasoning for varied quantum
20. 19
yields at the same excitation energy distances from their respective absorption maxima in this
thesis is likely to be the varying quality of PbSe quantum dots synthesized. The loss of energy
due to reduced quality of nanoparticles would most likely occur via defects in the crystal
structure or surface defects producing energy states that are higher in energy than the conduction
band edge, but lower in energy than Pe and De state energies (see figure 3). In multi-exciton
formation, the Auger process rate is higher than the rate of radiative decay, resulting in a reduced
quantum yield as the excitation energy increases in distance from the absorption maximum and
in energy. The loss of an electron via the Auger process leaves an electron hole in the valence
band of the quantum dot that was excited. In order to neutralize the quantum dot, the ejected
electron must come back in a redox mechanism that is unknown.
Conclusion:
Three lead-selenide colloidal quantum dot samples were synthesized and their
photoluminescence quantum yields were determined at three different energy distances on the
high energy side of their respective absorption excitons, and it was concluded that the quantum
yield decreases as the excitation energy distance from the absorption exciton energy increases.
This effect is due to an increased likelihood of multi-exciton formation resulting in an increased
rate of non-radiative Auger processes.
Bibliography:
(1) Engel, T. Quantum Chemistry & Spectroscopy; Third ed.; Pearson Higher Education:
Glenview, 2013.
(2) Singhal, S.; Nie, S.; Wang, M. D. Annual Review of Medicine 2010, 61, 359.
(3) Ladd, T. D.; Jelezko, F.; Laflamme, R.; Nakamura, Y.; Monroe, C.; O/'Brien, J. L.
Nature 2010, 464, 45.
21. 20
(4) Petta, J. R.; Johnson, A. C.; Taylor, J. M.; Laird, E. A.; Yacoby, A.; Lukin, M. D.;
Marcus, C. M.; Hanson, M. P.; Gossard, A. C. Science 2005, 309, 2180.
(5) Tang, J.; Sargent, E. H. Advanced Materials 2011, 23, 12.
(6) Ellingson, R. J.; Beard, M. C.; Johnson, J. C.; Yu, P.; Micic, O. I.; Nozik, A. J.; Shabaev,
A.; Efros, A. L. Nano Letters 2005, 5, 865.
(7) Zeghbroek, B. V.; University of Colorado: Boulder, Colorado, 2011.
(8) Klimov, V. I. Nanocrystal quantum dots; CRC Press Boca Raton, FL, 2010.
(9) Lakowicz, J. R. Principles of Fluorescence Spectroscopy; Springer: New York, 2006.
(10) Klimov, V. I.; Mikhailovsky, A. A.; McBranch, D. W.; Leatherdale, C. A.; Bawendi, M.
G. Science 2000, 287, 1011.
(11) Murray, C. B.; Sun, S.; Gaschler, W.; Doyle, H.; Betley, T. A.; Kagan, C. R. IBM
Journal of Research and Development 2001, 45, 47.
(12) Vittorio, M.; Pisanello, F.; Martiradonna, L.; Qualtieri, A.; Stomeo, T.; Bramati, A.;
Cingolani, R. Opto-Electron. Rev. 2010, 18, 1.
(13) Eaton, D. F. Pure and applied chemistry 1988, 60, 1107.
(14) Cao, J., Masters Graduate Student.