SlideShare ist ein Scribd-Unternehmen logo
1 von 102
Why do we need Solar tracking systems
Let us compare a power generation curve for a fixed PV module
and a dual axis tracked SPV system. We observe there are
certain advantages when using dual axis tracked modules:
1. Higher energy generation during sunrise and sunset.
2. Uniform generation during peak collection hours
3. Higher energy generation over the course of day.
 A solar tracker is a devise that orients a
solar panel in the direction of incident
sunlight.
 Solar trackers minimize the angle of
incidence between the incoming sunlight and
a photovoltaic panel, and increase power
generation.
 Ideally the sun rays should fall at an angle
of 90˚ to the plane of the photovoltaic
panel.
 By sun angles.
 We split the movement of the sun along the
solar ecliptic into a horizontal component
and a vertical component.
 The measure of the horizontal angle from the
true north meridian is called the solar
azimuth angle and the measure of the
vertical angle with respect to the ground is
called the elevation angle.
 Peak collection time is taken as the time
between 9am and 3pm, when the sun is highest
in the sky.
 Shading due to distant objects is minimal
during this time.
 Collection(or generation) is highest during
these hours.
 Hence fixed SPVs are usually oriented
anticipating sun rays to be coming from that
direction.
 Firstly due to the nature of the shape of the
earth (spherical), the rotation about a central
axis, this axis being tilted(i.e. not
perpendicular with respect to the plane of
rotation) and finally due to revolution about
sun.
 The first two causes namely spherical shape and
rotation about a central axis cause most of the
daily variation.
 The last two namely a tilted axis and revolution
about the sun cause seasonal variation.
 In summer the sun remains in the sky for a
longer time. Thus, solar azimuth variation
is greater during summer.
 In winter the sun stays in the sky for a
shorter time hence, solar azimuth variation
is smaller during winter.
 Solar declination is the latitude at which
the direct rays of the sun fall for a
particular day of the year.
 Solar declination changes over the course of
the year.
 It is shown in a curve known as the
analemma. It shows the sun position at a
particular time of day from a specific place
throughout the year.
Cause for change in solar declination
The reason for change in solar declination is as that which causes change
in lengths of day and night over the year and seasons, namely change in
orientation of earth’s rotation axis with respect to the sun.
 Solar declination = α
 Latitude = γ
 Solar elevation = [90˚ -(γ - α)]
 For the month of June in Calcutta,
 α=23.5 ˚North, γ=23.5 ˚North
 Therefore, solar elevation = [90 ˚-(23.5-
23.5)]=90 ˚.
 The change in solar declination over the
year causes change in the elevation angle of
sun as observed from a particular point at a
particular time.
 Thus the path of the sun as observed from
the point shifts up or down by a total of 47˚
over the course of the year.
 This creates the concept of solar window.
Table showing variation in optimum tilt angle of fixed
SPV in Calcutta.The values given below can also be interpreted as the
maximum sun elevation observed in the given months.. The
total variation in sun elevation over the course of the
year is approximately 47 degrees for any place on earth.
 From the table we observe the optimum tilt
angle for fixed SPVs in winter,
spring/autumn and summer and calculate the
average value:
 (0+23+23+46)/4 = 23˚ tilt angle with
respect to the horizontal is optimum for
fixed SPVs in Calcutta.
 As the angle of incidence of the incident
sunlight on the PV panel increases, the
power generated by the PV panel decreases
drastically.
 Fixed SPVs face oblique sun rays during
sunrise and sunset.
 Fixed SPVs are incapable of adjusting
position with respect to change in sun path
over the year.
 Single tracked SPV modules have east to west
rotation capabilities, i.e. they track the
sun’s azimuth angle and are capable of
generating 25% more power than fixed SPVs if
the proper tilt angle is provided.
 Dual axis tracking SPV modules can track the
sun’s elevation because they have North-
South rotation capabilities. They generate
around 8.3% more power than single axis
tracked SPV systems.
 Single axis trackers have one degree of
freedom that acts as an axis of rotation.
 The axis of rotation of single axis
trackers is typically aligned along a true
North meridian.
 The different types of single axis trackers
are:
i. Horizontal Single Axis Tracker(HSAT)
ii. Horizontal Single Axis Tracker with Tilted
Module(HTSAT)
iii. Vertical Single Axis Tracker(VSAT)
iv. Tilted Single Axis Tracker(TSAT)
 The axis of rotation for horizontal single axis
tracker is horizontal with respect to the
ground. The posts at either end of the axis of
rotation of a horizontal single axis tracker can
be shared between trackers to lower the
installation cost.
 Horizontal trackers typically have the face of
the module oriented parallel to the axis of
rotation. As a module tracks, it sweeps a
cylinder that is rotationally symmetric around
the axis of rotation.
 The axis of the tube is on a north–south line.
 In HSAT, the modules are mounted flat at 0
degrees, while in HTSAT, the modules are
installed at a certain tilt.
 These trackers are suitable in high latitude
locations but does not take as much land
space as consumed by Vertical single axis
tracker (VSAT).
 The axis of rotation for vertical single
axis trackers is vertical with respect to
the ground.
 Such trackers are more effective at high
latitudes than are horizontal axis trackers.
 As a module tracks, it sweeps a cone that is
rotationally symmetric around the axis of
rotation.
 These trackers have an axis of rotation
between horizontal and vertical.
 The face of the module is oriented parallel
to the axis of rotation.
 Dual axis trackers have two degrees of
freedom that act as axes of rotation.
 These axes are typically normal to one
another.
 The axis that is fixed with respect to the
ground can be considered a primary axis.
 Dual axis trackers typically have modules
oriented parallel to the secondary axis of
rotation.
 Two common implementations are :
1. tip-tilt dual axis trackers (TTDAT)
2. azimuth-altitude dual axis trackers
(AADAT).
 A tip–tilt dual axis tracker (TTDAT) is so-
named because the panel array is mounted on
the top of a pole.
 East–west movement is driven by rotating
the array around the top of the pole.
 On top of the rotating bearing is a T- or H-
shaped mechanism that provides vertical
rotation of the panels and provides the main
mounting points for the array.
 An azimuth–altitude dual axis tracker (AADAT)
has its primary axis (the azimuth axis) vertical
to the ground. The secondary axis, often called
elevation axis, is then typically normal to the
primary axis.
 AADAT systems can use a large ring mounted on
the ground with the array mounted on a series of
rollers. The main advantage of this arrangement
is the weight of the array is distributed over a
portion of the ring, as opposed to the single
loading point of the pole in the TTDAT.
Type of tracker % gain in generation
Latitude tilt fixed 23%
Horizontal tracked 37%
Horizontal tracked with tilted axis 64%
Dual axis tracked 71%
 Solar trackers require actuators to move the
tracker around either a single or dual axis.
 In order to control and manage the movement
of these massive structures special slewing
drives are designed.
 Linear actuators control movement in single
axis solar tracker or control elevation of a
dual-axis solar tracker.
 Slew drives are
used for the
rotation of a dual
axis tracker about
the vertical axis.
 There are two methods commonly employed for the
control of solar trackers. One is to use an
optical sensing system, and the other is to use
a mathematical equation. Both types of systems
usually employ a microprocessor based
controller which directs a motor to operate one
way or the other.
 The optical sensing system works better in
clear skies.
 Sun sensor is a device to measure the
incident angle of the sun rays when they
go through a small window. This allows,
the sensor to measure the Sun position or
other light sources regarding to the
sensor position.
 The sun sensors are designed over MEMS
technology (Micro-Electro Mechanical
Systems).
 Solar PV trackers do not require a position
accuracy of much better than a few degrees.
In that case, the motor-move-frequency can
be reduced to a move per degree or two,
which equates to one start/stop per 5-10
minutes.
 Trackers include moving parts and sophisticated
hardware, hence come at an added cost relative
to fixed tilt systems.
 Tracking systems tend to use additional land
space because they must be spaced out in order
to avoid shading one another.
 Operational and maintenance costs tend to be
higher for this type of system.
 In order for a tracker to make economic sense,
the increased energy harvest must exceed the
added cost of installing and maintaining
trackers over the lifetime of the system.
 Land area required for fixed tilt array<
Land area required for single axis tracked
array< land area required for dual axis
tracked array.
 This happens because of the movement of
structure and alignment of PV array
perpendicular to the direction of sunlight,
which tends to cause longer shadows around
the structure.
 Most Solar power plant employing trackers
adopt the backtracking algorithm to avoid
the shading effects which happen during
morning and late afternoons when sun height
is low.
 Backtracking algorithms help arrays to
position themselves such that inter shading
between different arrays do not happen.
 No, while solar trackers do involve moving
parts and might hence require some
maintenance. Note that the tracker movements
are slow and gradual and hence are not
subject to the same wear and tear that a
fast moving motor would.
 CUF=(Actual output of the solar plant over
the year)/(maximum possible output from it
in one year).
 Solar power plants with fixed tilt arrays
have CUF in the range 16-18% and if single
axis tracking is installed then CUF may go
up to 21-23%.
 Trackers usually add an extra cost for setup
extra O&M cost per year.
 They also require larger land area to
because tracking PV panels tend to generate
longer shadows around them.
 But the extra generation that is achieved
due to tracker implementation can recover
all these cost overturn the fortunes of a
power company.
Parameters Without Trackers With Trackers
Capital Cost(Rs,lakh) 5.75 6.15
CUF 18% 21%(couldgo up to
23%)
Plant Output(kWh,000) 16 19(could go up to 21)
Land Area 2178 2613.6
O&M
costs(000/MW/year)
5 7
 Added capital cost if using trackers
= (6.15 – 5.75)lakh rupees
= 0.4lakh rupees = 40,000 rupees
 Increase in plant output = (19,000 – 16,000)kWh
= 3,000 kWh
 Assuming PPA Tariff of Rs. 7/kWh,
Extra revenue generated per year
= (3,000X7) rupees = 21,000 rupees.
 The additional expense of Rs 40,000 usually pays
back within 2 years owing to extra generation.
 The ROI (Return on Investment ) for a PV
plant of 10kW capacity is quite good, as the
plant that employs a tracker will be
generating 19000 rupees worth of extra
revenue each year.
 Considering the lifetime of the plant to be
25 years. And expecting initial capital
costs to be recovered by 5 years, total
extra revenue generated per 10kW comes out
to be around 4lakh rupees for the entire
lifetime of the plant.
 If a shadow is cast on even just part of one
solar panel in a solar array, it can
compromise the output of the whole system.
 Depending on the voltage requirements of the
system’s inverters, solar arrays are
divided into ‘strings’ of solar panels.
 You can think of a string of panels as
something like a piece of pipe, and the
solar power is like water flowing through
that pipe. In conventional solar panel
strings, shade is something that blocks that
flow.
 Site your solar panel array where there will
be no regular shading.
 Using a string inverter with MPPT tracking
capabilities.
 Get a system with micro inverters or power
optimizers.
 MPPT is based on the principle of maximizing
power output from solar panels by varying
the resistance in the circuit.
 Example: When a cloud covers only a few PV
panels, then those panels receive less solar
radiation and operate under different
circuit conditions — they have a different
MPP.
 An MPP Tracker helps to minimize losses in
output associated with partial shading and other
panel output mismatches.
 An inverter equipped with an MPP Tracker (or
several of them) is able squeeze the most usable
energy possible out of a string of solar panels
(even when shaded) by adjusting the voltage to
always suit the inverter’s preferred input
range
 Inverters without MPPT capability simply lose
the output from the weaker string once it passes
below the required output threshold.
 Micro Inverters perform panel level MPPT
tracking.
 There is one micro inverter per SPV panel.
 The output from several micro inverters is
combined and fed to the electrical grid.
 Each micro inverter performs MPPT tracking
for its connected module and hence, small
amount of shading , or even complete module
failure does not drastically reduce the
output of the entire array.
 Simple construction.
 Lower amperage wires.
 Higher initial equipment cost since each
inverter needs to be installed adjacent to a
panel (usually on a roof).
 This also makes them harder to maintain and
more costly to remove and replace (O&M).
 Power optimizer employs similar technology
as that of micro inverter but it does not
convert to AC per module.
 Power Optimizers are provided with a
simplified version of string inverter for DC
to AC conversion.
String Inverter Micro Inverter
 String inverter
converts power from
all modules from DC to
AC(shading problem).
 Good for ground mount
or large roof.
 Difficult to expand.
 Cheap.
 Easy to maintain.
 Micro inverters work
at the module level –
converts power from
each module.
 Good for roof made of
many small areas.
 Easy to expand.
 Costly .
 Difficult to maintain.
 http://solarelectricityhandbook.com/solar-
angle-calculator.html
 https://en.wikipedia.org/wiki/Solar_tracker
 https://www.solarchoice.net.au/blog/partial-
shading-is-bad-for-solar-panels-power-
systems
 https://www.youtube.com/
Solar tracking systems

Weitere ähnliche Inhalte

Was ist angesagt?

Automatic sun tracking system
Automatic sun tracking systemAutomatic sun tracking system
Automatic sun tracking system
Sreekanth Shastry
 
Solar tracking system
Solar tracking systemSolar tracking system
Solar tracking system
Parviz Bora
 
Solar tracking system by naidu
Solar tracking system by naiduSolar tracking system by naidu
Solar tracking system by naidu
Naidu Turpati
 
Abstract on solar energy tracking system
Abstract on solar energy tracking systemAbstract on solar energy tracking system
Abstract on solar energy tracking system
Sreekanth Shastry
 

Was ist angesagt? (20)

Dual axis solar tracking system using microcontroller
Dual axis solar tracking system using microcontrollerDual axis solar tracking system using microcontroller
Dual axis solar tracking system using microcontroller
 
Seminar on AUTOMATIC SOLAR TRACKING SYSTEM
Seminar on AUTOMATIC SOLAR TRACKING SYSTEMSeminar on AUTOMATIC SOLAR TRACKING SYSTEM
Seminar on AUTOMATIC SOLAR TRACKING SYSTEM
 
Automatic sun tracking system
Automatic sun tracking systemAutomatic sun tracking system
Automatic sun tracking system
 
Solar tracker
Solar trackerSolar tracker
Solar tracker
 
Project Report
Project ReportProject Report
Project Report
 
Solar tracking system
Solar tracking systemSolar tracking system
Solar tracking system
 
Solar tracking system
Solar tracking systemSolar tracking system
Solar tracking system
 
Solar tracker
Solar trackerSolar tracker
Solar tracker
 
Automatic sun tracking system. ppt
Automatic sun tracking system. pptAutomatic sun tracking system. ppt
Automatic sun tracking system. ppt
 
Universal solar tracker final report
Universal solar tracker final reportUniversal solar tracker final report
Universal solar tracker final report
 
solar tracker by kanav mansotra
solar tracker by kanav mansotrasolar tracker by kanav mansotra
solar tracker by kanav mansotra
 
Solar tracking system using 8051 microcontroller
Solar tracking system using 8051 microcontrollerSolar tracking system using 8051 microcontroller
Solar tracking system using 8051 microcontroller
 
Oro551 res - unit 1 - instruments for measuring solar radiation and sun shine
Oro551   res - unit 1 - instruments for measuring solar radiation and sun shineOro551   res - unit 1 - instruments for measuring solar radiation and sun shine
Oro551 res - unit 1 - instruments for measuring solar radiation and sun shine
 
Final ppt on automatic solar traking system
Final ppt on automatic solar traking systemFinal ppt on automatic solar traking system
Final ppt on automatic solar traking system
 
Solar tracking system by naidu
Solar tracking system by naiduSolar tracking system by naidu
Solar tracking system by naidu
 
DUAL AXIS SOLAR TRACKER USING LDR AS A SENSOR
DUAL AXIS SOLAR TRACKER USING LDR AS A SENSORDUAL AXIS SOLAR TRACKER USING LDR AS A SENSOR
DUAL AXIS SOLAR TRACKER USING LDR AS A SENSOR
 
Abstract on solar energy tracking system
Abstract on solar energy tracking systemAbstract on solar energy tracking system
Abstract on solar energy tracking system
 
Sun tracking solar panel
Sun tracking solar panelSun tracking solar panel
Sun tracking solar panel
 
Design and performance analysis of 500 KWp on-grid solar PV system
Design and performance analysis of 500 KWp on-grid solar PV systemDesign and performance analysis of 500 KWp on-grid solar PV system
Design and performance analysis of 500 KWp on-grid solar PV system
 
Solar tracker
Solar trackerSolar tracker
Solar tracker
 

Ähnlich wie Solar tracking systems

A5-SOLAR-TRACKING-SYSTEM
A5-SOLAR-TRACKING-SYSTEMA5-SOLAR-TRACKING-SYSTEM
A5-SOLAR-TRACKING-SYSTEM
TANMOY GHOSH
 
Dual Axis Solar Tracking System with Weather Sensor
Dual Axis Solar Tracking System with Weather SensorDual Axis Solar Tracking System with Weather Sensor
Dual Axis Solar Tracking System with Weather Sensor
ijtsrd
 

Ähnlich wie Solar tracking systems (20)

Sts
StsSts
Sts
 
IRJET- Dual Axis Solar Tracking System using LDR Sensors
IRJET- Dual Axis Solar Tracking System using LDR SensorsIRJET- Dual Axis Solar Tracking System using LDR Sensors
IRJET- Dual Axis Solar Tracking System using LDR Sensors
 
Ec6004 unit 2
Ec6004 unit 2Ec6004 unit 2
Ec6004 unit 2
 
Solar Trackers & Its Economic
Solar Trackers  & Its EconomicSolar Trackers  & Its Economic
Solar Trackers & Its Economic
 
Solartracking-review.pdf
Solartracking-review.pdfSolartracking-review.pdf
Solartracking-review.pdf
 
Solartracking review
Solartracking reviewSolartracking review
Solartracking review
 
Solar-Tracking-System-PPT.pptx
Solar-Tracking-System-PPT.pptxSolar-Tracking-System-PPT.pptx
Solar-Tracking-System-PPT.pptx
 
Solar-Tracking-System-PPT.pptx
Solar-Tracking-System-PPT.pptxSolar-Tracking-System-PPT.pptx
Solar-Tracking-System-PPT.pptx
 
Solar-Tracking-System-PPT.pptx
Solar-Tracking-System-PPT.pptxSolar-Tracking-System-PPT.pptx
Solar-Tracking-System-PPT.pptx
 
Solar-Tracking-System-PPT.pptx
Solar-Tracking-System-PPT.pptxSolar-Tracking-System-PPT.pptx
Solar-Tracking-System-PPT.pptx
 
Solar-Tracking-System-PPT.pptx
Solar-Tracking-System-PPT.pptxSolar-Tracking-System-PPT.pptx
Solar-Tracking-System-PPT.pptx
 
Solar tracking-system-ppt
Solar tracking-system-pptSolar tracking-system-ppt
Solar tracking-system-ppt
 
solar tracker.docx
solar tracker.docxsolar tracker.docx
solar tracker.docx
 
A5-SOLAR-TRACKING-SYSTEM
A5-SOLAR-TRACKING-SYSTEMA5-SOLAR-TRACKING-SYSTEM
A5-SOLAR-TRACKING-SYSTEM
 
MY ME PROJECT 2013-2015
MY ME PROJECT 2013-2015MY ME PROJECT 2013-2015
MY ME PROJECT 2013-2015
 
Dual Axis Solar Tracking System with Weather Sensor
Dual Axis Solar Tracking System with Weather SensorDual Axis Solar Tracking System with Weather Sensor
Dual Axis Solar Tracking System with Weather Sensor
 
IRJET - Study and Analysis of Arduino based Solar Tracking Panel
IRJET - Study and Analysis of Arduino based Solar Tracking PanelIRJET - Study and Analysis of Arduino based Solar Tracking Panel
IRJET - Study and Analysis of Arduino based Solar Tracking Panel
 
Solar control
Solar controlSolar control
Solar control
 
A Review On Solar Tracking System A Technique Of Solar Power Output Enhancement
A Review On Solar Tracking System  A Technique Of Solar Power Output EnhancementA Review On Solar Tracking System  A Technique Of Solar Power Output Enhancement
A Review On Solar Tracking System A Technique Of Solar Power Output Enhancement
 
Performance analysis of mono crystalline silicon technology with different or...
Performance analysis of mono crystalline silicon technology with different or...Performance analysis of mono crystalline silicon technology with different or...
Performance analysis of mono crystalline silicon technology with different or...
 

Kürzlich hochgeladen

Making and Justifying Mathematical Decisions.pdf
Making and Justifying Mathematical Decisions.pdfMaking and Justifying Mathematical Decisions.pdf
Making and Justifying Mathematical Decisions.pdf
Chris Hunter
 
Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in DelhiRussian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
kauryashika82
 
Beyond the EU: DORA and NIS 2 Directive's Global Impact
Beyond the EU: DORA and NIS 2 Directive's Global ImpactBeyond the EU: DORA and NIS 2 Directive's Global Impact
Beyond the EU: DORA and NIS 2 Directive's Global Impact
PECB
 
Seal of Good Local Governance (SGLG) 2024Final.pptx
Seal of Good Local Governance (SGLG) 2024Final.pptxSeal of Good Local Governance (SGLG) 2024Final.pptx
Seal of Good Local Governance (SGLG) 2024Final.pptx
negromaestrong
 
The basics of sentences session 3pptx.pptx
The basics of sentences session 3pptx.pptxThe basics of sentences session 3pptx.pptx
The basics of sentences session 3pptx.pptx
heathfieldcps1
 

Kürzlich hochgeladen (20)

PROCESS RECORDING FORMAT.docx
PROCESS      RECORDING        FORMAT.docxPROCESS      RECORDING        FORMAT.docx
PROCESS RECORDING FORMAT.docx
 
Making and Justifying Mathematical Decisions.pdf
Making and Justifying Mathematical Decisions.pdfMaking and Justifying Mathematical Decisions.pdf
Making and Justifying Mathematical Decisions.pdf
 
Asian American Pacific Islander Month DDSD 2024.pptx
Asian American Pacific Islander Month DDSD 2024.pptxAsian American Pacific Islander Month DDSD 2024.pptx
Asian American Pacific Islander Month DDSD 2024.pptx
 
Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in DelhiRussian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
 
Unit-IV- Pharma. Marketing Channels.pptx
Unit-IV- Pharma. Marketing Channels.pptxUnit-IV- Pharma. Marketing Channels.pptx
Unit-IV- Pharma. Marketing Channels.pptx
 
Nutritional Needs Presentation - HLTH 104
Nutritional Needs Presentation - HLTH 104Nutritional Needs Presentation - HLTH 104
Nutritional Needs Presentation - HLTH 104
 
Explore beautiful and ugly buildings. Mathematics helps us create beautiful d...
Explore beautiful and ugly buildings. Mathematics helps us create beautiful d...Explore beautiful and ugly buildings. Mathematics helps us create beautiful d...
Explore beautiful and ugly buildings. Mathematics helps us create beautiful d...
 
ComPTIA Overview | Comptia Security+ Book SY0-701
ComPTIA Overview | Comptia Security+ Book SY0-701ComPTIA Overview | Comptia Security+ Book SY0-701
ComPTIA Overview | Comptia Security+ Book SY0-701
 
Beyond the EU: DORA and NIS 2 Directive's Global Impact
Beyond the EU: DORA and NIS 2 Directive's Global ImpactBeyond the EU: DORA and NIS 2 Directive's Global Impact
Beyond the EU: DORA and NIS 2 Directive's Global Impact
 
Basic Civil Engineering first year Notes- Chapter 4 Building.pptx
Basic Civil Engineering first year Notes- Chapter 4 Building.pptxBasic Civil Engineering first year Notes- Chapter 4 Building.pptx
Basic Civil Engineering first year Notes- Chapter 4 Building.pptx
 
Measures of Dispersion and Variability: Range, QD, AD and SD
Measures of Dispersion and Variability: Range, QD, AD and SDMeasures of Dispersion and Variability: Range, QD, AD and SD
Measures of Dispersion and Variability: Range, QD, AD and SD
 
microwave assisted reaction. General introduction
microwave assisted reaction. General introductionmicrowave assisted reaction. General introduction
microwave assisted reaction. General introduction
 
Seal of Good Local Governance (SGLG) 2024Final.pptx
Seal of Good Local Governance (SGLG) 2024Final.pptxSeal of Good Local Governance (SGLG) 2024Final.pptx
Seal of Good Local Governance (SGLG) 2024Final.pptx
 
ICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptxICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptx
 
The basics of sentences session 3pptx.pptx
The basics of sentences session 3pptx.pptxThe basics of sentences session 3pptx.pptx
The basics of sentences session 3pptx.pptx
 
Sociology 101 Demonstration of Learning Exhibit
Sociology 101 Demonstration of Learning ExhibitSociology 101 Demonstration of Learning Exhibit
Sociology 101 Demonstration of Learning Exhibit
 
INDIA QUIZ 2024 RLAC DELHI UNIVERSITY.pptx
INDIA QUIZ 2024 RLAC DELHI UNIVERSITY.pptxINDIA QUIZ 2024 RLAC DELHI UNIVERSITY.pptx
INDIA QUIZ 2024 RLAC DELHI UNIVERSITY.pptx
 
Measures of Central Tendency: Mean, Median and Mode
Measures of Central Tendency: Mean, Median and ModeMeasures of Central Tendency: Mean, Median and Mode
Measures of Central Tendency: Mean, Median and Mode
 
Mehran University Newsletter Vol-X, Issue-I, 2024
Mehran University Newsletter Vol-X, Issue-I, 2024Mehran University Newsletter Vol-X, Issue-I, 2024
Mehran University Newsletter Vol-X, Issue-I, 2024
 
Ecological Succession. ( ECOSYSTEM, B. Pharmacy, 1st Year, Sem-II, Environmen...
Ecological Succession. ( ECOSYSTEM, B. Pharmacy, 1st Year, Sem-II, Environmen...Ecological Succession. ( ECOSYSTEM, B. Pharmacy, 1st Year, Sem-II, Environmen...
Ecological Succession. ( ECOSYSTEM, B. Pharmacy, 1st Year, Sem-II, Environmen...
 

Solar tracking systems

  • 1.
  • 2.
  • 3.
  • 4. Why do we need Solar tracking systems Let us compare a power generation curve for a fixed PV module and a dual axis tracked SPV system. We observe there are certain advantages when using dual axis tracked modules: 1. Higher energy generation during sunrise and sunset. 2. Uniform generation during peak collection hours 3. Higher energy generation over the course of day.
  • 5.  A solar tracker is a devise that orients a solar panel in the direction of incident sunlight.
  • 6.  Solar trackers minimize the angle of incidence between the incoming sunlight and a photovoltaic panel, and increase power generation.  Ideally the sun rays should fall at an angle of 90˚ to the plane of the photovoltaic panel.
  • 7.
  • 8.
  • 9.  By sun angles.  We split the movement of the sun along the solar ecliptic into a horizontal component and a vertical component.  The measure of the horizontal angle from the true north meridian is called the solar azimuth angle and the measure of the vertical angle with respect to the ground is called the elevation angle.
  • 10.
  • 11.
  • 12.  Peak collection time is taken as the time between 9am and 3pm, when the sun is highest in the sky.  Shading due to distant objects is minimal during this time.  Collection(or generation) is highest during these hours.  Hence fixed SPVs are usually oriented anticipating sun rays to be coming from that direction.
  • 13.  Firstly due to the nature of the shape of the earth (spherical), the rotation about a central axis, this axis being tilted(i.e. not perpendicular with respect to the plane of rotation) and finally due to revolution about sun.  The first two causes namely spherical shape and rotation about a central axis cause most of the daily variation.  The last two namely a tilted axis and revolution about the sun cause seasonal variation.
  • 14.
  • 15.
  • 16.  In summer the sun remains in the sky for a longer time. Thus, solar azimuth variation is greater during summer.  In winter the sun stays in the sky for a shorter time hence, solar azimuth variation is smaller during winter.
  • 17.
  • 18.
  • 19.
  • 20.
  • 21.
  • 22.
  • 23.
  • 24.  Solar declination is the latitude at which the direct rays of the sun fall for a particular day of the year.  Solar declination changes over the course of the year.  It is shown in a curve known as the analemma. It shows the sun position at a particular time of day from a specific place throughout the year.
  • 25. Cause for change in solar declination The reason for change in solar declination is as that which causes change in lengths of day and night over the year and seasons, namely change in orientation of earth’s rotation axis with respect to the sun.
  • 26.  Solar declination = α  Latitude = γ  Solar elevation = [90˚ -(γ - α)]
  • 27.  For the month of June in Calcutta,  α=23.5 ˚North, γ=23.5 ˚North  Therefore, solar elevation = [90 ˚-(23.5- 23.5)]=90 ˚.
  • 28.
  • 29.  The change in solar declination over the year causes change in the elevation angle of sun as observed from a particular point at a particular time.  Thus the path of the sun as observed from the point shifts up or down by a total of 47˚ over the course of the year.  This creates the concept of solar window.
  • 30. Table showing variation in optimum tilt angle of fixed SPV in Calcutta.The values given below can also be interpreted as the maximum sun elevation observed in the given months.. The total variation in sun elevation over the course of the year is approximately 47 degrees for any place on earth.
  • 31.  From the table we observe the optimum tilt angle for fixed SPVs in winter, spring/autumn and summer and calculate the average value:  (0+23+23+46)/4 = 23˚ tilt angle with respect to the horizontal is optimum for fixed SPVs in Calcutta.
  • 32.
  • 33.
  • 34.  As the angle of incidence of the incident sunlight on the PV panel increases, the power generated by the PV panel decreases drastically.  Fixed SPVs face oblique sun rays during sunrise and sunset.  Fixed SPVs are incapable of adjusting position with respect to change in sun path over the year.
  • 35.  Single tracked SPV modules have east to west rotation capabilities, i.e. they track the sun’s azimuth angle and are capable of generating 25% more power than fixed SPVs if the proper tilt angle is provided.
  • 36.
  • 37.
  • 38.  Dual axis tracking SPV modules can track the sun’s elevation because they have North- South rotation capabilities. They generate around 8.3% more power than single axis tracked SPV systems.
  • 39.
  • 40.
  • 41.
  • 42.
  • 43.
  • 44.  Single axis trackers have one degree of freedom that acts as an axis of rotation.  The axis of rotation of single axis trackers is typically aligned along a true North meridian.
  • 45.  The different types of single axis trackers are: i. Horizontal Single Axis Tracker(HSAT) ii. Horizontal Single Axis Tracker with Tilted Module(HTSAT) iii. Vertical Single Axis Tracker(VSAT) iv. Tilted Single Axis Tracker(TSAT)
  • 46.  The axis of rotation for horizontal single axis tracker is horizontal with respect to the ground. The posts at either end of the axis of rotation of a horizontal single axis tracker can be shared between trackers to lower the installation cost.  Horizontal trackers typically have the face of the module oriented parallel to the axis of rotation. As a module tracks, it sweeps a cylinder that is rotationally symmetric around the axis of rotation.  The axis of the tube is on a north–south line.
  • 47.
  • 48.  In HSAT, the modules are mounted flat at 0 degrees, while in HTSAT, the modules are installed at a certain tilt.  These trackers are suitable in high latitude locations but does not take as much land space as consumed by Vertical single axis tracker (VSAT).
  • 49.
  • 50.  The axis of rotation for vertical single axis trackers is vertical with respect to the ground.  Such trackers are more effective at high latitudes than are horizontal axis trackers.  As a module tracks, it sweeps a cone that is rotationally symmetric around the axis of rotation.
  • 51.
  • 52.  These trackers have an axis of rotation between horizontal and vertical.  The face of the module is oriented parallel to the axis of rotation.
  • 53.
  • 54.  Dual axis trackers have two degrees of freedom that act as axes of rotation.  These axes are typically normal to one another.  The axis that is fixed with respect to the ground can be considered a primary axis.  Dual axis trackers typically have modules oriented parallel to the secondary axis of rotation.
  • 55.
  • 56.
  • 57.
  • 58.  Two common implementations are : 1. tip-tilt dual axis trackers (TTDAT) 2. azimuth-altitude dual axis trackers (AADAT).
  • 59.  A tip–tilt dual axis tracker (TTDAT) is so- named because the panel array is mounted on the top of a pole.  East–west movement is driven by rotating the array around the top of the pole.  On top of the rotating bearing is a T- or H- shaped mechanism that provides vertical rotation of the panels and provides the main mounting points for the array.
  • 60.
  • 61.  An azimuth–altitude dual axis tracker (AADAT) has its primary axis (the azimuth axis) vertical to the ground. The secondary axis, often called elevation axis, is then typically normal to the primary axis.  AADAT systems can use a large ring mounted on the ground with the array mounted on a series of rollers. The main advantage of this arrangement is the weight of the array is distributed over a portion of the ring, as opposed to the single loading point of the pole in the TTDAT.
  • 62.
  • 63.
  • 64. Type of tracker % gain in generation Latitude tilt fixed 23% Horizontal tracked 37% Horizontal tracked with tilted axis 64% Dual axis tracked 71%
  • 65.
  • 66.
  • 67.  Solar trackers require actuators to move the tracker around either a single or dual axis.  In order to control and manage the movement of these massive structures special slewing drives are designed.  Linear actuators control movement in single axis solar tracker or control elevation of a dual-axis solar tracker.
  • 68.
  • 69.  Slew drives are used for the rotation of a dual axis tracker about the vertical axis.
  • 70.  There are two methods commonly employed for the control of solar trackers. One is to use an optical sensing system, and the other is to use a mathematical equation. Both types of systems usually employ a microprocessor based controller which directs a motor to operate one way or the other.  The optical sensing system works better in clear skies.
  • 71.  Sun sensor is a device to measure the incident angle of the sun rays when they go through a small window. This allows, the sensor to measure the Sun position or other light sources regarding to the sensor position.  The sun sensors are designed over MEMS technology (Micro-Electro Mechanical Systems).
  • 72.
  • 73.  Solar PV trackers do not require a position accuracy of much better than a few degrees. In that case, the motor-move-frequency can be reduced to a move per degree or two, which equates to one start/stop per 5-10 minutes.
  • 74.
  • 75.  Trackers include moving parts and sophisticated hardware, hence come at an added cost relative to fixed tilt systems.  Tracking systems tend to use additional land space because they must be spaced out in order to avoid shading one another.  Operational and maintenance costs tend to be higher for this type of system.  In order for a tracker to make economic sense, the increased energy harvest must exceed the added cost of installing and maintaining trackers over the lifetime of the system.
  • 76.  Land area required for fixed tilt array< Land area required for single axis tracked array< land area required for dual axis tracked array.  This happens because of the movement of structure and alignment of PV array perpendicular to the direction of sunlight, which tends to cause longer shadows around the structure.
  • 77.  Most Solar power plant employing trackers adopt the backtracking algorithm to avoid the shading effects which happen during morning and late afternoons when sun height is low.  Backtracking algorithms help arrays to position themselves such that inter shading between different arrays do not happen.
  • 78.  No, while solar trackers do involve moving parts and might hence require some maintenance. Note that the tracker movements are slow and gradual and hence are not subject to the same wear and tear that a fast moving motor would.
  • 79.  CUF=(Actual output of the solar plant over the year)/(maximum possible output from it in one year).  Solar power plants with fixed tilt arrays have CUF in the range 16-18% and if single axis tracking is installed then CUF may go up to 21-23%.
  • 80.  Trackers usually add an extra cost for setup extra O&M cost per year.  They also require larger land area to because tracking PV panels tend to generate longer shadows around them.  But the extra generation that is achieved due to tracker implementation can recover all these cost overturn the fortunes of a power company.
  • 81. Parameters Without Trackers With Trackers Capital Cost(Rs,lakh) 5.75 6.15 CUF 18% 21%(couldgo up to 23%) Plant Output(kWh,000) 16 19(could go up to 21) Land Area 2178 2613.6 O&M costs(000/MW/year) 5 7
  • 82.  Added capital cost if using trackers = (6.15 – 5.75)lakh rupees = 0.4lakh rupees = 40,000 rupees  Increase in plant output = (19,000 – 16,000)kWh = 3,000 kWh  Assuming PPA Tariff of Rs. 7/kWh, Extra revenue generated per year = (3,000X7) rupees = 21,000 rupees.  The additional expense of Rs 40,000 usually pays back within 2 years owing to extra generation.
  • 83.  The ROI (Return on Investment ) for a PV plant of 10kW capacity is quite good, as the plant that employs a tracker will be generating 19000 rupees worth of extra revenue each year.  Considering the lifetime of the plant to be 25 years. And expecting initial capital costs to be recovered by 5 years, total extra revenue generated per 10kW comes out to be around 4lakh rupees for the entire lifetime of the plant.
  • 84.
  • 85.  If a shadow is cast on even just part of one solar panel in a solar array, it can compromise the output of the whole system.
  • 86.  Depending on the voltage requirements of the system’s inverters, solar arrays are divided into ‘strings’ of solar panels.
  • 87.  You can think of a string of panels as something like a piece of pipe, and the solar power is like water flowing through that pipe. In conventional solar panel strings, shade is something that blocks that flow.
  • 88.  Site your solar panel array where there will be no regular shading.  Using a string inverter with MPPT tracking capabilities.  Get a system with micro inverters or power optimizers.
  • 89.  MPPT is based on the principle of maximizing power output from solar panels by varying the resistance in the circuit.  Example: When a cloud covers only a few PV panels, then those panels receive less solar radiation and operate under different circuit conditions — they have a different MPP.
  • 90.
  • 91.  An MPP Tracker helps to minimize losses in output associated with partial shading and other panel output mismatches.  An inverter equipped with an MPP Tracker (or several of them) is able squeeze the most usable energy possible out of a string of solar panels (even when shaded) by adjusting the voltage to always suit the inverter’s preferred input range  Inverters without MPPT capability simply lose the output from the weaker string once it passes below the required output threshold.
  • 92.
  • 93.  Micro Inverters perform panel level MPPT tracking.  There is one micro inverter per SPV panel.  The output from several micro inverters is combined and fed to the electrical grid.
  • 94.  Each micro inverter performs MPPT tracking for its connected module and hence, small amount of shading , or even complete module failure does not drastically reduce the output of the entire array.  Simple construction.  Lower amperage wires.
  • 95.
  • 96.  Higher initial equipment cost since each inverter needs to be installed adjacent to a panel (usually on a roof).  This also makes them harder to maintain and more costly to remove and replace (O&M).
  • 97.
  • 98.  Power optimizer employs similar technology as that of micro inverter but it does not convert to AC per module.  Power Optimizers are provided with a simplified version of string inverter for DC to AC conversion.
  • 99.
  • 100. String Inverter Micro Inverter  String inverter converts power from all modules from DC to AC(shading problem).  Good for ground mount or large roof.  Difficult to expand.  Cheap.  Easy to maintain.  Micro inverters work at the module level – converts power from each module.  Good for roof made of many small areas.  Easy to expand.  Costly .  Difficult to maintain.
  • 101.  http://solarelectricityhandbook.com/solar- angle-calculator.html  https://en.wikipedia.org/wiki/Solar_tracker  https://www.solarchoice.net.au/blog/partial- shading-is-bad-for-solar-panels-power- systems  https://www.youtube.com/