SlideShare ist ein Scribd-Unternehmen logo
1 von 52
Plate Heat
Exchanger
Group 18
Amit Yadav - 19CHE187
Yashvir Koul - 19CHE188
Sakshi Patil - 19CHE189
Prasanna Gangawane - 19CHE190
Kalyan Mali - 18CHE179
Siddhesh Borole - 18CHE151
Abhigyan Ray - 17CHE103
Plate Heat Exchanger
• A PHE consists of a pack of thin rectangular plates with portholes, through
which two fluid streams flow, where heat transfer takes place.
• Other components are a frame plate (fixed plate), a pressure plate (movable
plate), upper and lower bars and screws for compressing the pack of plates.
• An individual plate heat exchanger can hold up to 700 plates.
• When the package of plates is compressed, the holes in the corners of the
plates form continuous tunnels or manifolds through which fluids pass,
traversing the plate pack and exiting the equipment.
• The spaces between the thin heat exchanger plates form narrow channels
that are alternately traversed by hot and cold fluids, and provide little
resistance to heat transfer.
Block Diagram
PHEX
TI
TC TT
TI
TI
Thermic Fluid in
Process Fluid Out
Thermic Fluid Outlet
Process
Fluid
Inlet
FM
FM
• The total heat transfer rate between the fluids passing through a plate heat
exchanger can be expressed by the following equation:
• Where U, A, and ∆Tm are the overall heat transfer coefficient, total plate area,
and the effective mean temperature difference respectively.
• The total plate area can be calculated as follows:
• Np and Ap are the number of plates (except the end plates) and the area of each
plate.
• Also, the overall heat transfer coefficient is expressed as:
• where hhot and hcold are convective heat transfer coefficients of hot and cold
fluids, respectively. tp and kp are plate thickness and conductivity of platesand Rf,
hot and Rf, cold are fouling factors of hot and cold fluids.
Dynamic Modelling
Transfer Function Derivation
Where,
Now, converting time domain equations to Laplace domain
Eq 2
Plate Gap =δp = 0.005 m
Plate Length = Lp = 1m
Plate Width = bp =1m
Number of Plate =N= 100
Heat Transfer Area of 1 plate = A =1 m2
CPh =4184 J/kg ͦC
Cpc =4179 J/kg ͦC
KH = 0.6318 W/m ͦC
ρH = 984.4 kg/m3
DATA
Constants
R
d1 d2
Gc Gv
Gd1 Gd2
Gp
H
C(s)
Feedback Control System
Transfer function
(Consider P only controller)
Open loop transfer function
Phase lag
-300
-250
-200
-150
-100
-50
0
-4 -3 -2 -1 0 1 2
ϕ
log(w)
ϕ
-180
-160
-140
-120
-100
-80
-60
-40
-20
0
20
40
-5 -4 -3 -2 -1 0 1 2 3
dB
LOG(W)
dB
Bode Plot
To find cross over frequency
Now,
PID Design
Analysis
Analysis
Analysis
Flow Measurement
Voltage Amplifier
Temperature Measurement
Control Valves
Process Instrumentation
Flow Measurement
• Maintaining proper flow of fluids in a process system is
essential to maintain correct supply of raw materials to
reactors, correct supply of water or steam for cooling or
heating purpose etc.
• Flow meters sense the amount of flow passing through a
particular pipe and sends this information to process controller
which then applies process logic and sends control information
to control valves or pump control unit.
• A variety of flow meters are used in process industry
depending on type of fluid, operating temperatures and
pressures, required flow accuracy and economy.
• An orifice meter consists of an orifice plate, a holding
device, upstream downstream meter piping, and
pressure taps. By far the most critical part of the
meter is the orifice plate, particularly the widely used
square-edged concentric plate, whose construction
requirements are well documented in standards such
as AGA-3 and ISO 5167-1. These standards define the
plate’s edge, flatness, thickness—with bevel details, if
required—and bore limitations.
• The most common holding system is a pair of
orifice flanges. However, for more precise
measurement, various fittings are used. These
simplify plate installation/removal for changing flow
ranges and for easy inspection. In every case, the
orifice must be installed concentric with the pipe
within limits stated by the standard.
Orifice meter
Advantages of Orifice meter
• The Orifice is small plates and easy to install/remove.
• Offer very little pressure drop from which 60% to 65% is
recovered.
• The orifice meter can be easily maintained.
• Measures a wide range of flows.
• They have a simple construction.
• They have easily fitted between the flanges.
• They are the most suitable for most gases and liquids.
• They are cheap, The price does not increase dramatically
with size
Voltage Amplifier
• Voltage Amplifier put out a higher voltage than the input voltageand are commonly used
to increase the voltage and thus the amount of power coming out of a circuit.
• Analog Modules, Inc. (AMI) designs and manufactures a range of voltage amplifiers for
OEM, medical and research applications. AMI’s amplifiers combine low noise, high gain,
large dynamic range, and small package size.
• The 321A Series are ultra low noise voltage amplifiers designed for instrument and
transducer applications in which high gain and low noise are required. Both low and high
input impedances are available.
• The 351A Series are low noise voltage amplifiers designed for instrument and transducer
applications in which low drift and low noise are required. Both low and high input
impedances are available.
• The Model 353A is a low noise voltage amplifier designed for instrument and transducer
applications in which high bandwidth and low noise are required.
Temperature Measurement
• A thermocouple converts thermal energy
into electrical energy and the amount of
electrical energy generated can be used to
measure temperature.
• Thermocouples are constructed from two
wire leads made from different metals. The
wire leads are welded together to create a
junction. As the temperature changes from
the junction to the ends of the wire leads, a
voltage develops across the junction.
All dissimilar metals used to construct a thermocouple display
a change in voltage from the Seebeck effect, but several
specific combinations are used to make thermocouples.
The thermocouples can be classified into two different
construction types: base metal thermocouples and noble metal
thermocouples.
Base metal thermocouples are the most common
thermocouples. Noble metal thermocouples are composed of
precious metals such as platinum and rhodium. Noble metal
thermocouples are more expensive, and are used in higher
temperature applications.
Regardless of metal lead, each thermocouple type is designated
a single letter to indicate the two metals used. For example, a J-
type thermocouple is constructed from iron and constantan.
With each type, the thermoelectric properties are standardized
so that temperature measurements are repeatable.
Thermocouple leads and connectors are standardized with color
plugs and jacks, indicating the type of thermocouple. Different
colors for insulation and lead wires also indicate the
thermocouple grade and extension grade.
The National Institute of Standards and Technology (NIST)
has analyzed the output voltage versus temperature for the
various types of thermocouples. Figure 2 illustrates the
typical responses for these same thermocouple types.
Tolerance Standards
• Temperature measurement accuracy and range depend on the type
of the thermocouple used and the standard followed by the
manufacturer.
• The International Electrotechnical Commission standard outlined in
IEC-EN 60584 contains the manufacturing tolerances for base metal
and noble metal thermocouples. A parallel standard used in the
United States from the American Society for Testing and Materials
is described by ASTM E230.
• The table shows the tolerance of different thermocouples based on
different standards and tolerance classes.
Control Valves
• A globe control valve is a type of valve used for regulating
flow in a pipeline, consisting of a movable plug or disc
element and a stationary ring seat in a generally spherical
body.
• Globe valves are named for their spherical body shape
with the two halves of the body being separated by an
internal baffle. It has an opening that forms a seat onto
which a movable plug can be screwed in to close (or shut)
the valve. The plug is also called a disc.
• In globe valves, the plug is connected to a stem which is
operated by screw action using a handwheel in manual
valves. The body is the main pressure containing structure
of the valve and the most easily identified as it forms the
mass of the valve. It contains all of the valve's internal
parts that will come in contact with the substance being
controlled by the valve.
Working `
• A globe valve is primarily designed to stop, start and
regulate flow. A globe valve consists of a movable disk
and a stationary ring seat in a spherical body.
• The seat of a globe valve is in the middle of and parallel
to the pipe, and the opening in the seat is closed off with
the disk.
• When the handwheel is rotated manually or by an
actuator, the disc movement is controlled (lowered or
raised) by means of the valve stem.
• When the globe valve disc seats over the seat ring, the
flow is completely stopped.
Advantages
• Good shutoff capability
• Moderate to good throttling capability
• Shorter stroke (compared to a gate valve)
• Available in tee, wye, and angle patterns, each offering unique
capabilities
• Easy to machine or resurface the seats
• With disc not attached to the stem, valve can be used as a stop-check
valve.
Disadvantages
• Higher pressure drop (compared to a gate valve)
• Requires greater force or a larger actuator to seat the valve (with
pressure under the seat)
• Throttling flow under the seat and shutoff flow over the seat.
References
• https://www.intechopen.com/chapters/48647
• https://www.linquip.com/blog/working-principle-plate-heat-exchanger
• Al-Dawery, S. K., Alrahawi, A. M., & Al-Zobai, K. M. (2012). Dynamic modeling and control of
plate heat exchanger. International Journal of Heat and Mass Transfer, 55(23-24), 6873-6880.
• Al-Dawery, S. K., Alrahawi, A. M., & Al-Zobai, K. M. (2012). Dynamic modeling and control of
plate heat exchanger. International Journal of Heat and Mass Transfer, 55(23-24), 6873-6880.
• Saranya, S. N., Sivakumar, V. M., Thirumarimurugan, M., & Sowparnika, G. C. (2017, January).
Modeling and control of plate type heat exchangers using PI and PID controllers. In 2017
11th International Conference on Intelligent Systems and Control (ISCO) (pp. 439-443). IEEE.
• Bastida, H., Ugalde-Loo, C. E., Abeysekera, M., & Qadrdan, M. (2017, November). Dynamic
modeling and control of a plate heat exchanger. In 2017 IEEE Conference on Energy Internet
and Energy System Integration (EI2) (pp. 1-6). IEEE
Thank you!
Plate Heat Exchanger-controller_design.pptx
Plate Heat Exchanger-controller_design.pptx
Plate Heat Exchanger-controller_design.pptx
Plate Heat Exchanger-controller_design.pptx

Weitere ähnliche Inhalte

Ähnlich wie Plate Heat Exchanger-controller_design.pptx

Ähnlich wie Plate Heat Exchanger-controller_design.pptx (20)

CPD - PHE's Principles _ Applications(1) - High Res.pdf
CPD - PHE's Principles _ Applications(1) - High Res.pdfCPD - PHE's Principles _ Applications(1) - High Res.pdf
CPD - PHE's Principles _ Applications(1) - High Res.pdf
 
HEAT_EXCHANGER_Final.pptx
HEAT_EXCHANGER_Final.pptxHEAT_EXCHANGER_Final.pptx
HEAT_EXCHANGER_Final.pptx
 
HEAT_EXCHANGER_Final.ppt
HEAT_EXCHANGER_Final.pptHEAT_EXCHANGER_Final.ppt
HEAT_EXCHANGER_Final.ppt
 
PPT on Heat Exchanger.19.ppt
PPT on Heat Exchanger.19.pptPPT on Heat Exchanger.19.ppt
PPT on Heat Exchanger.19.ppt
 
Heat Exchanger pdf.pptx
Heat Exchanger pdf.pptxHeat Exchanger pdf.pptx
Heat Exchanger pdf.pptx
 
heat exchanger
heat exchangerheat exchanger
heat exchanger
 
Design And Fabrication of Turbulator for swirl motion flow study Setup
Design And Fabrication of Turbulator for swirl motion flow study SetupDesign And Fabrication of Turbulator for swirl motion flow study Setup
Design And Fabrication of Turbulator for swirl motion flow study Setup
 
Technical Module - PHE
Technical Module - PHETechnical Module - PHE
Technical Module - PHE
 
Mel709 39
Mel709 39Mel709 39
Mel709 39
 
selfstudy-5.pptx
selfstudy-5.pptxselfstudy-5.pptx
selfstudy-5.pptx
 
selfstudy-5.ppt
selfstudy-5.pptselfstudy-5.ppt
selfstudy-5.ppt
 
selfstudy-5.ppt
selfstudy-5.pptselfstudy-5.ppt
selfstudy-5.ppt
 
selfstudy-5.ppt
selfstudy-5.pptselfstudy-5.ppt
selfstudy-5.ppt
 
selfstudy-5.ppt
selfstudy-5.pptselfstudy-5.ppt
selfstudy-5.ppt
 
HE.ppt
HE.pptHE.ppt
HE.ppt
 
selfstudy-5.ppt
selfstudy-5.pptselfstudy-5.ppt
selfstudy-5.ppt
 
plate heate exchanger
plate heate exchanger plate heate exchanger
plate heate exchanger
 
Transformer Designing
Transformer Designing Transformer Designing
Transformer Designing
 
Design of fin plate heat exchanger
Design of fin plate heat exchangerDesign of fin plate heat exchanger
Design of fin plate heat exchanger
 
ALBA MANUFACTURING OF TRANSFORMERS.pptx
ALBA MANUFACTURING OF TRANSFORMERS.pptxALBA MANUFACTURING OF TRANSFORMERS.pptx
ALBA MANUFACTURING OF TRANSFORMERS.pptx
 

Kürzlich hochgeladen

Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak HamilCara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Kandungan 087776558899
 
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
9953056974 Low Rate Call Girls In Saket, Delhi NCR
 

Kürzlich hochgeladen (20)

Online electricity billing project report..pdf
Online electricity billing project report..pdfOnline electricity billing project report..pdf
Online electricity billing project report..pdf
 
Moment Distribution Method For Btech Civil
Moment Distribution Method For Btech CivilMoment Distribution Method For Btech Civil
Moment Distribution Method For Btech Civil
 
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptxOrlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
 
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak HamilCara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
 
DC MACHINE-Motoring and generation, Armature circuit equation
DC MACHINE-Motoring and generation, Armature circuit equationDC MACHINE-Motoring and generation, Armature circuit equation
DC MACHINE-Motoring and generation, Armature circuit equation
 
AIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech studentsAIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech students
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPT
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - V
 
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
 
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptxHOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
 
A CASE STUDY ON CERAMIC INDUSTRY OF BANGLADESH.pptx
A CASE STUDY ON CERAMIC INDUSTRY OF BANGLADESH.pptxA CASE STUDY ON CERAMIC INDUSTRY OF BANGLADESH.pptx
A CASE STUDY ON CERAMIC INDUSTRY OF BANGLADESH.pptx
 
kiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal loadkiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal load
 
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
COST-EFFETIVE  and Energy Efficient BUILDINGS ptxCOST-EFFETIVE  and Energy Efficient BUILDINGS ptx
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
 
Work-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptxWork-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptx
 
Computer Lecture 01.pptxIntroduction to Computers
Computer Lecture 01.pptxIntroduction to ComputersComputer Lecture 01.pptxIntroduction to Computers
Computer Lecture 01.pptxIntroduction to Computers
 
Block diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.pptBlock diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.ppt
 
Introduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaIntroduction to Serverless with AWS Lambda
Introduction to Serverless with AWS Lambda
 
PE 459 LECTURE 2- natural gas basic concepts and properties
PE 459 LECTURE 2- natural gas basic concepts and propertiesPE 459 LECTURE 2- natural gas basic concepts and properties
PE 459 LECTURE 2- natural gas basic concepts and properties
 
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
 
Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...
Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...
Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...
 

Plate Heat Exchanger-controller_design.pptx

  • 1. Plate Heat Exchanger Group 18 Amit Yadav - 19CHE187 Yashvir Koul - 19CHE188 Sakshi Patil - 19CHE189 Prasanna Gangawane - 19CHE190 Kalyan Mali - 18CHE179 Siddhesh Borole - 18CHE151 Abhigyan Ray - 17CHE103
  • 2. Plate Heat Exchanger • A PHE consists of a pack of thin rectangular plates with portholes, through which two fluid streams flow, where heat transfer takes place. • Other components are a frame plate (fixed plate), a pressure plate (movable plate), upper and lower bars and screws for compressing the pack of plates. • An individual plate heat exchanger can hold up to 700 plates. • When the package of plates is compressed, the holes in the corners of the plates form continuous tunnels or manifolds through which fluids pass, traversing the plate pack and exiting the equipment. • The spaces between the thin heat exchanger plates form narrow channels that are alternately traversed by hot and cold fluids, and provide little resistance to heat transfer.
  • 3. Block Diagram PHEX TI TC TT TI TI Thermic Fluid in Process Fluid Out Thermic Fluid Outlet Process Fluid Inlet FM FM
  • 4. • The total heat transfer rate between the fluids passing through a plate heat exchanger can be expressed by the following equation: • Where U, A, and ∆Tm are the overall heat transfer coefficient, total plate area, and the effective mean temperature difference respectively. • The total plate area can be calculated as follows: • Np and Ap are the number of plates (except the end plates) and the area of each plate. • Also, the overall heat transfer coefficient is expressed as: • where hhot and hcold are convective heat transfer coefficients of hot and cold fluids, respectively. tp and kp are plate thickness and conductivity of platesand Rf, hot and Rf, cold are fouling factors of hot and cold fluids. Dynamic Modelling
  • 6.
  • 7. Where, Now, converting time domain equations to Laplace domain Eq 2
  • 8.
  • 9.
  • 10. Plate Gap =δp = 0.005 m Plate Length = Lp = 1m Plate Width = bp =1m Number of Plate =N= 100 Heat Transfer Area of 1 plate = A =1 m2 CPh =4184 J/kg ͦC Cpc =4179 J/kg ͦC KH = 0.6318 W/m ͦC ρH = 984.4 kg/m3 DATA
  • 12. R d1 d2 Gc Gv Gd1 Gd2 Gp H C(s) Feedback Control System
  • 13. Transfer function (Consider P only controller)
  • 14.
  • 15.
  • 16.
  • 17. Open loop transfer function Phase lag
  • 18. -300 -250 -200 -150 -100 -50 0 -4 -3 -2 -1 0 1 2 ϕ log(w) ϕ -180 -160 -140 -120 -100 -80 -60 -40 -20 0 20 40 -5 -4 -3 -2 -1 0 1 2 3 dB LOG(W) dB Bode Plot
  • 19. To find cross over frequency Now,
  • 22.
  • 23.
  • 25.
  • 26.
  • 28.
  • 29.
  • 30. Flow Measurement Voltage Amplifier Temperature Measurement Control Valves Process Instrumentation
  • 31. Flow Measurement • Maintaining proper flow of fluids in a process system is essential to maintain correct supply of raw materials to reactors, correct supply of water or steam for cooling or heating purpose etc. • Flow meters sense the amount of flow passing through a particular pipe and sends this information to process controller which then applies process logic and sends control information to control valves or pump control unit. • A variety of flow meters are used in process industry depending on type of fluid, operating temperatures and pressures, required flow accuracy and economy.
  • 32. • An orifice meter consists of an orifice plate, a holding device, upstream downstream meter piping, and pressure taps. By far the most critical part of the meter is the orifice plate, particularly the widely used square-edged concentric plate, whose construction requirements are well documented in standards such as AGA-3 and ISO 5167-1. These standards define the plate’s edge, flatness, thickness—with bevel details, if required—and bore limitations. • The most common holding system is a pair of orifice flanges. However, for more precise measurement, various fittings are used. These simplify plate installation/removal for changing flow ranges and for easy inspection. In every case, the orifice must be installed concentric with the pipe within limits stated by the standard. Orifice meter
  • 33. Advantages of Orifice meter • The Orifice is small plates and easy to install/remove. • Offer very little pressure drop from which 60% to 65% is recovered. • The orifice meter can be easily maintained. • Measures a wide range of flows. • They have a simple construction. • They have easily fitted between the flanges. • They are the most suitable for most gases and liquids. • They are cheap, The price does not increase dramatically with size
  • 34. Voltage Amplifier • Voltage Amplifier put out a higher voltage than the input voltageand are commonly used to increase the voltage and thus the amount of power coming out of a circuit. • Analog Modules, Inc. (AMI) designs and manufactures a range of voltage amplifiers for OEM, medical and research applications. AMI’s amplifiers combine low noise, high gain, large dynamic range, and small package size. • The 321A Series are ultra low noise voltage amplifiers designed for instrument and transducer applications in which high gain and low noise are required. Both low and high input impedances are available. • The 351A Series are low noise voltage amplifiers designed for instrument and transducer applications in which low drift and low noise are required. Both low and high input impedances are available. • The Model 353A is a low noise voltage amplifier designed for instrument and transducer applications in which high bandwidth and low noise are required.
  • 35.
  • 36. Temperature Measurement • A thermocouple converts thermal energy into electrical energy and the amount of electrical energy generated can be used to measure temperature. • Thermocouples are constructed from two wire leads made from different metals. The wire leads are welded together to create a junction. As the temperature changes from the junction to the ends of the wire leads, a voltage develops across the junction.
  • 37.
  • 38.
  • 39.
  • 40. All dissimilar metals used to construct a thermocouple display a change in voltage from the Seebeck effect, but several specific combinations are used to make thermocouples. The thermocouples can be classified into two different construction types: base metal thermocouples and noble metal thermocouples. Base metal thermocouples are the most common thermocouples. Noble metal thermocouples are composed of precious metals such as platinum and rhodium. Noble metal thermocouples are more expensive, and are used in higher temperature applications. Regardless of metal lead, each thermocouple type is designated a single letter to indicate the two metals used. For example, a J- type thermocouple is constructed from iron and constantan. With each type, the thermoelectric properties are standardized so that temperature measurements are repeatable. Thermocouple leads and connectors are standardized with color plugs and jacks, indicating the type of thermocouple. Different colors for insulation and lead wires also indicate the thermocouple grade and extension grade.
  • 41. The National Institute of Standards and Technology (NIST) has analyzed the output voltage versus temperature for the various types of thermocouples. Figure 2 illustrates the typical responses for these same thermocouple types.
  • 42. Tolerance Standards • Temperature measurement accuracy and range depend on the type of the thermocouple used and the standard followed by the manufacturer. • The International Electrotechnical Commission standard outlined in IEC-EN 60584 contains the manufacturing tolerances for base metal and noble metal thermocouples. A parallel standard used in the United States from the American Society for Testing and Materials is described by ASTM E230. • The table shows the tolerance of different thermocouples based on different standards and tolerance classes.
  • 43.
  • 44. Control Valves • A globe control valve is a type of valve used for regulating flow in a pipeline, consisting of a movable plug or disc element and a stationary ring seat in a generally spherical body. • Globe valves are named for their spherical body shape with the two halves of the body being separated by an internal baffle. It has an opening that forms a seat onto which a movable plug can be screwed in to close (or shut) the valve. The plug is also called a disc. • In globe valves, the plug is connected to a stem which is operated by screw action using a handwheel in manual valves. The body is the main pressure containing structure of the valve and the most easily identified as it forms the mass of the valve. It contains all of the valve's internal parts that will come in contact with the substance being controlled by the valve.
  • 45. Working ` • A globe valve is primarily designed to stop, start and regulate flow. A globe valve consists of a movable disk and a stationary ring seat in a spherical body. • The seat of a globe valve is in the middle of and parallel to the pipe, and the opening in the seat is closed off with the disk. • When the handwheel is rotated manually or by an actuator, the disc movement is controlled (lowered or raised) by means of the valve stem. • When the globe valve disc seats over the seat ring, the flow is completely stopped.
  • 46. Advantages • Good shutoff capability • Moderate to good throttling capability • Shorter stroke (compared to a gate valve) • Available in tee, wye, and angle patterns, each offering unique capabilities • Easy to machine or resurface the seats • With disc not attached to the stem, valve can be used as a stop-check valve. Disadvantages • Higher pressure drop (compared to a gate valve) • Requires greater force or a larger actuator to seat the valve (with pressure under the seat) • Throttling flow under the seat and shutoff flow over the seat.
  • 47. References • https://www.intechopen.com/chapters/48647 • https://www.linquip.com/blog/working-principle-plate-heat-exchanger • Al-Dawery, S. K., Alrahawi, A. M., & Al-Zobai, K. M. (2012). Dynamic modeling and control of plate heat exchanger. International Journal of Heat and Mass Transfer, 55(23-24), 6873-6880. • Al-Dawery, S. K., Alrahawi, A. M., & Al-Zobai, K. M. (2012). Dynamic modeling and control of plate heat exchanger. International Journal of Heat and Mass Transfer, 55(23-24), 6873-6880. • Saranya, S. N., Sivakumar, V. M., Thirumarimurugan, M., & Sowparnika, G. C. (2017, January). Modeling and control of plate type heat exchangers using PI and PID controllers. In 2017 11th International Conference on Intelligent Systems and Control (ISCO) (pp. 439-443). IEEE. • Bastida, H., Ugalde-Loo, C. E., Abeysekera, M., & Qadrdan, M. (2017, November). Dynamic modeling and control of a plate heat exchanger. In 2017 IEEE Conference on Energy Internet and Energy System Integration (EI2) (pp. 1-6). IEEE