SlideShare ist ein Scribd-Unternehmen logo
1 von 28
Downloaden Sie, um offline zu lesen
saving you energy
Save 20-50% on heating
& cooling costs with
Airius Destratification
Visit us atwww.airius.co.uk
Recommended by The Carbon Trust*
SAVE ENERGY,
CUT COSTS,
REDUCE CARBON
EMISSIONS
saving you energy
Save 20-50% on heating
& cooling costs with
Airius Destratification
Recommended by The Carbon Trust*
SAVE ENERGY,
CUT COSTS,
REDUCE CARBON
EMISSIONS
Visit us atwww.airius.co.uk
©2015 AIRIUS Europe Ltd. USA and Foreign Patents Pending. AIRIUS®
*
Airius has helped thousands
of businesses, from SMEs to major
Blue Chip companies make real
reductions in their energy usage and
carbon emissions.
04.
06.
08.
10.
12.
14.
15.
16.
20.
22.
25.
Installation process
Patented Stator Technology
How does it work?
USPs
FAQs
Our product range
The Standard Series
All-inclusive features
The Designer Series
The discreet solution
System Speed Controls
Variable on/off speed controls
The Suspended Series
Suspended ceiling integration
Assured quality
Testimonials
Project gallery
Case studies
Contact information
Table of Contents
TRUST IN
AIRIUS
18.
Formed in 2004, we have revolutionised
the industry with our market leading
thermal destratification systems,
which have helped balance the internal
temperatures in public and commercial
buildings all across the world. As
testament to the efficiency of the Airius
system, we have quickly built up an
extensive and prestigious client base
including well-known brands like Boots,
British Airways, Mercedes, Morrisons and
many more.
4
Recommended by the Carbon Trust, Destratification systems
are one of the most effective energy reduction technologies
available on the market.[
Installation
process
installed into new or existing builds
and have been installed into Grade I, II*
and II listed buildings for numerous clients.
The installation process is very simple
and can be installed in a short space of
time. The difference will be instantly
noticeable and will improve the comfort
levels in your building.
Tphenomenon that affects all
buildings and results in a dramatic
phenomenon occurs when hot air rises
towards the ceiling or roof, as it is lighter
than the surrounding cool air. In contrast,
The main negative consequence of
Ventilation and Air Conditioning (HVAC)
systems in your building will be working in
overdrive to maintain set temperatures at
HVAC systems which are constantly
overdelivering will be costing your
in performance and lost energy. There
will also be a negative impact on your
company’s carbon footprint.
Wasted heat will inevitably rise and
accumulate at the ceiling of your building,
(0.5ºC – 2ºC per metre on average).
Conversely, heavier cooled air which is
by sinking to low points in a building or
circulate areas.
What will Airius do?
To combat the problem of thermal
will balance internal temperatures,
by recycling the heated or cooled air
supplied or accumulated from people,
processes or solar gain, and circulating
temperatures fully throughout your
entire building.
Our systems will also
reduce the operation time and workload
required of heating and cooling systems.
The difference will be instantly
noticeable, improving not just comfort
levels in your building but also the
therefore maximising savings.
Installation
process
Patented Stator
Technology
RECOMMENDED
BY THE CARBON
TRUST
• Reduces heating costs by 30% - 50%
• Reduces cooling costs by 20% - 40%
• Maintains optimum working / retail
environment
• Reduces CO2 emissions by 20% - 50%
• Rapid ROI - usually between 12 - 24
months
• 3 year warranty
• Customers include FTSE100
companies to SMEs
• Eligible for carbon reducing grants /
loans
• Established and proven technology
• Increases lighting lifespan
• Minimal maintenance required
• Minimal running costs (from £6/pa)
• Recycles heat from machinery,
lighting, solar gain etc
• Reduces condensation
• Reduces wear on existing HVAC
equipment
• Simple to install with no ducting
required
•
ESOS / CRC Solution
• Small, versatile, unobtrusive units
• Stand alone or BMS integrated
• Works alongside all types of HVAC
systems
55
With any fan, the spinning blades induce
a rotational component into the air
stream causing turbulence and reduced
throw distance.
Airius’ patented multi-vane stator
technology transfers this rotational
energy to create an invisible column of air
(columnar laminar flow), increasing throw
distance. This is a standard feature on all
Airius ranges.
With the Airius systems’ patented multi-
vane stator technology, temperatures are
balanced to within 1°C - 2°C.
How does it work?
Discover how Airius’ market leading features and benefits
compare to the competition, offering the most cost effective
destratification solution available.[
O
The Airius ceiling-mounted axial turbine fan
Pros 20 - 50% energy savings | 1ºC - 2ºC temperature variance | Low energy consumption (12W+) | Silent
operation | Lightweight, small and unobtrusive | Avoids draught disturbance | Simple installation | BSRIA
tested |
Cons Roof level installation.
Unit Cost Running Cost
Figures above are based upon equivalent systems: ¹Powrmatic CEC
3750, ²Ambirad/Benson DS10 & ³Airius Model 60.
£500
5,000kWh
15,000kWh
25,000kWh 35,000kWh
£1,500
£2,500
£3,500
Leading wall
Box Fan1
Leading ceiling
Box Fan2
Airius Range3
6
40m
12m
8.5m
These are installed at ceiling
height, sending air to the floor in
a slow-moving column. This uses
low levels of power, pushing air
through a very small space.
Once it reaches floor level, the airflow blankets out in all directions before rising and
being recirculated through the fan. Ultra quiet with minimal air movement, ideal for
noise-sensitive environments. Savings on average between 20 - 50%, although higher
levels have been recorded (see Lush Cosmetics Case Study, page 23).
77
The ‘blade’ or paddle fan
Pros 5 - 10% energy savings | Low energy consumption.
Cons Temperature variance 8ºC - 12ºC | Roof level Installation | spread disperses before
40m
12m
8.5m
The wall-mounted box fan
height and angled upwards. They
send air at high velocity upwards
to push warm air gathered at the ceiling
Pros 10 - 15% energy savings – Although this is offset against high running costs | Low Level Installation.
Cons Temperature variance 8ºC - 12ºC | Noisy | High energy usage – 450kWh+ | Large, heavy units –
Average 35kg to 95kg | Recommended installation at head height, which can cause accident and injury.
40m
12m
8.5m
The ceiling-mounted box fan
and send high velocity air directly
problems and can pick up and
circulate dust particles. They are also high energy consumers and not suitable for noise
sensitive environments.
Pros 5 - 10% energy savings – Although this is offset against high running costs.
Cons Temperature variance 5ºC - 10ºC | Noisy | High energy usage – 450kWh+ | Large, heavy units –
Average 35kg to 95kg | Roof level installation.
40m
12m
8.5m
Overhead ducted fans
Installed at ceiling height sending
required to overcome the friction of
to circulate and instead immediately rises back to the ceiling. Installation of the ducting
is also expensive and time-consuming, causing extended disruption to a building’s
normal operation.
Pros 5 - 10% energy savings.
Cons Localised temperature variance 4ºC - 8ºC near exhausts | | Poor
| Floor plans must be adapted placing work stations near duct exhausts | Ducting and its
installation is expensive and disruptive | Extensive high and low level ducting installation.
40m
12m
8.5m
The cheapest option, works by
‘churning’ the air. However, it is not
organised and the airflow disperses
before it can reach the floor (see
smoke test video at (www.airius.co.uk).
FAQs
[
W
hat is the typical rate of
to ceiling?
of 0.5 –2ºC per metre and temperature
differentials of up to 10°C are common
over a height of 10 metres. In extreme
cases, temperature differentials of
10°C have been found over a height of
3 metres.
a number of factors such as the building
materials, level of insulation, activity in the
building, heating/cooling set points and
the outside temperature.
It is wrong to assume that if the level of
scale there is not much to be gained.
This can be down to a number of reasons,
such as:
• Insulation levels are so low, heat
escapes before it can build up. Our
best case studies have been from
buildings like this
• Outside temperature is at or above
room temperature
• The heating is off
When do you start saving?
Immediately! The moment the units
building and HVAC system will start to
improve, reaching their full potential once
equalisation is achieved (within 48 hours
depending on the size of the building).
How much can I expect to save on
heating?
Savings range hugely from building to
building with average savings of 30 –
50%. With over 100,000 units sold, we
have had reported savings ranging from
20% to 76%. This is down to a number of
factors, such as:
• Ceiling Height
• Insulation
• Achieving Temperature
• Levels of Process / Ambient heat
How does the Airius system work
with cooling?
The way Airius units work to reduce
cooling costs is slightly different to
heating. Typically in cooled spaces, people
near the cooling outlet are too cold and
those no more than a few metres away
are too hot. People by windows can also
get too hot due to solar gain and so on.
The Airius units help by equalising the
temperature making sure that everyone
possible. It also helps the cool air reach
thermostat set points quicker.
The Airius system also ensures that
every cubic metre of air in the building
is moving very slowly. This gentle air
movement across the skin creates a lower
perceived temperature (evaporative
cooling), allowing you to turn your
thermostat up by between 2ºC and 4ºC,
yet maintain the same conditions or
better for occupants.
>
8
Discover the true potential and value of Destratification, as
we answer some of the key and frequently asked questions set
by our clients.
9
happily carry out a full site survey free of
Call: +44 (0)1202 554 200
Email:
FREE
SITE SURVEY
SUPPLIED
£11.56
£14.45
£29.87
£40.47
£120.45
£168.63
£115.63
£163.81
£375.80
£385.44
MODEL
NUMBER
Model 10
Model 15
Model 25
Model 45/PS-4
Model 45/PS-2
Model 45/EC
Model 60/PS-4
Model 60/EC
Model 100/EC
Model 125/EL
12 Watts
15 Watts
31 Watts
42 Watts
125 Watts
175 Watts
120 Watts
170 Watts
390 Watts
400 Watts
POWER
CONSUMPTION
ANNUAL
RUNNING COST
How much do Airius units cost to run?
electrical load, using less than 5% of the power of
running costs, based on the units running 24 hours
a day, 365 days a year, at an electrical cost of 11
pence per kWh.
WE ARE VERY
IMPRESSED WITH THE
AIRIUS FANS IN OUR
BOWLING CENTRE AT
NANTGARW. WE’VE
NOW INCREASED OUR
THERMOSTATS FROM 19°C
TO 23.5°C RESULTING IN A
SAVING OF OVER 70% ON
OUR COOLING COSTS!
Bowlplex PLC
“
THE AIRIUS SYSTEM
WAS INSTALLED DURING
THE SUMMER WHILST THE
AC SYSTEM WAS CLOSED
DOWN FOR SERVICING AND
WE WERE HAPPY TO FIND
THE ENVIRONMENT NOW
COMFORTABLE WITHOUT
THE AC RUNNING.
Tiso Ltd
“
This along with the equalised
temperature has proven to
reduce cooling costs from 20%
up to 100%. This is due to the
low cooling requirement in the
UK. You only need to reduce
the cooling load slightly to make
huge savings.
9
4m - 6m
9m - 11m
60m² - 90m²
230
15
1230
406
690
0.06
0 - 21dB(A)
6.5m - 8m
11m - 13m
89m² - 133m²
230
31
1450
459
780
0.14
0 - 31dB(A)
8.5m - 14m
11m - 13m
89m² - 133m²
230
42
1450
595
1010
0.19
0 - 35dB(A)
2.5m - 3.5m
8m - 10m
48m² - 72m²
230
12
980
318
540
0.06
0 - 21dB(A)
Our product range
Explore the most versatile and efficient destratification fans
available, which ensure temperatures provided by heating and
cooling are maintained efficiently throughout internal spaces.[
Airius units are
available as free
hanging fans
applicable for
ceiling heights from
2.5m to 40m, or
can be installed into
suspended ceilings
up to 15m high
with our 600mm x
600mm Suspended
Series kit
(see page 14).”
Tech Specs Model 10 Model 15 Model 25
Ceiling Heights
Dia. Coverage
Floor Area Coverage
Volts¹
RPM @ 50 Hz¹
CFM @ 50 Hz¹
m³/hr¹
AMPS @ 50 Hz¹
Noise Level²
Model 10
Height: 444mm
Rim height: 311mm
Width: 325mm
Weight: 3.2kg
Model 15
Height: 546mm
Rim height: 413mm
Width: 325mm
Weight: 4.1kg
Model 25
Height: 546mm
Rim Height: 413mm
Width: 325mm
Weight: 4.1kg
Model 45
Height: 605mm
Rim height: 455mm
Width: 375mm
Weight: 6.3kg
Model 60
Height: 823mm
Rim height: 607mm
Width: 498mm
Weight: 9.9kg
Model 100
Height: 843mm
Width: 495mm
Weight: 20.4kg
Standard Series
¹Motor data provided by motor manufacturer and is subject to change at any
time. Data above is calculated at 50Hz.
Model 45/PS-4
10
15m - 20m
14m - 17m
148m² - 222m²
230
120
1390
1667
2832
0.57
0 - 38dB(A)
17m - 22m
14m - 17m
155m² - 232m²
230
170
1630
1770
3007
1.30
0 - 38dB(A)
20m - 33m
15m - 19m
186m² - 279m²
230
390
1690
3358
5705
2.50
0 - 34dB(A)
12m - 15m
11m - 14m
100m² - 150m²
230
125
2450
1072
1821
0.54
0 - 44dB(A)
13m - 16m
12m - 15m
111m² - 167m²
230
175
3050
1290
2192
1.40
0 - 49dB(A)
supplier to specify your system.
Model 45/PS-2 Model 45/EC Model 60/PS-4 Model 60/EC Model 100 Model 125
Model 125
Height: 938mm
Width: 690mm
Weight: 45.3kg
Model 60
Height: 838mm
Rim height: 610mm
Width: 492mm
Weight: 17.2kg
Model 45
Height: 610mm
Rim height: 452mm
Width: 373mm
Weight: 8.6kg
Model 25
Height: 538mm
Rim height: 400mm
Width: 333mm
Weight: 6.8kg
Model 15
Height: 538mm
Rim height: 400mm
Width: 333mm
Weight: 6.8kg
Designer Series
Series warranty
Warranty. Simply return defective units to Airius, carriage paid
and upon receipt Airius will dispatch a new unit by return carriage
fully paid.
To avoid refurbishment and
cleaning charges, all units
returned must adhere to the
returns criteria.
www.airius.co.uk/airius-warranty-
terms-conditions
1111
20m - 40m
17m - 21m
223m² - 334m²
200-277
400
1000
5200
8835
1.80
0 - 31dB(A)
Model 10
Height: 436mm
Rim height: 299mm
Width: 333mm
Weight: 5.4kg
Standard Series
F
irst released in 2004, The Airius Standard Series
throughout the world.
The Airius Standard Series is available in several
models with various motor and control options
available to accommodate your building’s unique
All models in the Standard Series range feature
motors, which are suspended just below ceiling height
in your building. This series is suitable for buildings
with a ceiling height of 2.5 metres, right up to
33 metres.
From the short Model 10 to the Model 100, the
Standard Series range is capable of equalising
per fan.
All products in the Standard Series are supplied
in an off-white colour. However, if requested
we have the facilities to custom paint your
code.
Call Airius today to receive a personalised
quotation for your company.
[
Since its first release in 2004, the Airius Standard Series
has been the go-to free hanging fan, used to combat
thermal stratification in buildings across the world.
Call Airius today to receive
a fully tailored quotation for
your building.
+44 (0)1202 554 200
O
12
Leash anchor
The leash anchor point
is another standard
feature on all Airius
when fully installed.
All-inclusive features
Adaptability
Adaptable bail and
eye bolts allow easy
be angled 90o
and 360o
horizontally
(see website for guides).
Cord length
1.5 metre cord length
as standard, which can
be wired onto a circuit
or powered standalone
plug (not supplied).
Ultra quiet
All Airius fans are
ultra-quiet and can
environments such as
and even libraries.
STANDARD
s e r i e s
1313
+44 (0)1202 554 200
Designer Series
[
T
he Airius Designer Series shares many similarities to our
Standard Series and will provide your building with all of
However, models from the Designer Series are enclosed in
a powder coated aluminium cylindrical housing and are
perfectly suited to architecturally sensitive installations.
All models in the Designer Series operate in exactly
the same manner as models from the Standard
Series. We can customise the Designer Series
with motor and control options to suit your
paint the units to match any RAL colour code.
The Designer Series is suitable for
installation in properties with ceiling
heights ranging from 2.5 metres, right
up to 40m high.
Contact our team today for a
personalised quotation.
The Airius Designer Series
provides you with a solution to
suit any building, blending in
with environments effortlessly
without taking on the
appearance of a typical fan.
The discreet solution
Save energy in style and specify the Airius Designer
Series, which is enclosed in an aluminium cylindrical
housing and can be tailored to any custom colour.
14
1 Amp Controller
The 1 Amp Controller suitable for:
• 16 x Airius Model 10’s
• 13 x Airius Model 15’s
• 6 x Airius Model 25’s
• 4 x Airius Model 45/PS-4’s
• 1 x Airius Model 45/PS-2
• 1 x Airius Model 60/PS-4
All Airius systems are designed to operate on a 24/7 basis for maximum
Our speed controllers feature a speed control dial that is easy to operate and install in
onto circuits of the same Airius model.
Airius supplies the following types of speed controllers:
System Speed Controls
5 Amp Controller
The 5 Amp Controller suitable for:
• 83 x Airius Model 10’s
• 66 x Airius Model 15’s
• 32 x Airius Model 25’s
• 23 x Airius Model 45/PS-4’s
• 8 x Airius Model 45/PS-2’s
• 8 x Airius Model 60/PS-4’s
EC Controller
The EC controller is suitable for Airius EC and EL models only.
DESIGNER
s e r i e s
Log on to the Airius website
and discover for
your business.
www.airius.co.uk
Or call: +44 (0)1202 554 200
1515
Suspended Series
[
T
he Airius Suspended Series is suitable for buildings
with dropped, false or suspended ceilings or where an
unobtrusive and discreet installation
is required. Thermal
many buildings, not
only in the UK but all
around the world and is a
leading contributor to high
energy costs and increased
carbon footprints.
The Airius Suspended Series will ensure
that there is a constant recirculation of
air and balance temperatures throughout
your building, saving you 20% to 50% on your
heating/cooling costs and reducing your carbon
footprint considerably.
The Airius Suspended Series is an additional piece
of equipment that houses an Airius Standard Series
from just below the ceiling before it escapes into the void
above. Suitable for buildings with a ceiling height of 2.5
metres up to 15 metres, the Suspended Series is simple to
install meeting standard European ceiling grid dimensions
(600mm x 600mm) and is easily adaptable to changing
All models in the Suspended Series are available in off-white
or can also be custom painted to match any RAL colour code.
For installations into suspended, dropped or false
ceilings Airius supply a suspended ceiling kit, which is
sized to fit standard European ceiling tile dimensions.
Email Airius today,
complete with your details &
site reference for a 24hr reply.
Or call: +44 (0)1202 554 200
16
17
Suspended ceiling integration
SUSPENDED
s e r i e s
Weight & dimensions
Note: Standard Series fan nozzles will
lengths depending upon the model.
See below:
Model 10 (Short) = 120mm
Model 10, 15 & 25 = 222mm
Model 45 = 219mm
Weight = 3.6kgs (*4kgs) | Ceiling Height = 2.5m - 15m |
| )
Min ceiling
void required
400mm
(*460mm)
267mm
(*335mm)
413mm
600mm
600mm
57mm
1717
DOME
FACE PLATE
*Applies to Model 45 (8.5m - 16m) Suspended Series Kit
To accommodate the Suspended Series and to allow working space for installation
we recommend a minimum ceiling void of 400mm (460mm for Model 45
Suspended Series), however customers have been able to install the
Suspended Series into a void as little as 300mm.
Assured quality
Airius Destratification fans have been installed into many
commercial, private, public and government buildings.
Discover who we work with and what they have to say.[
Customer testimonials
First winter savings of
£62,251 measured against a total
system spend of £21,268!
““We installed 34 Airius units into the
assembly plant at our manufacturing site
and I am very pleased with the results.
The heating system now comes on far less
and employees who work in this building
are much warmer. Overall savings
equaled 45.07%.
The full cost of the Airius units is
recouped within a matter of months -
against a total system spend of £21,268!
I will be looking at other buildings on
our site and recommending Airius to
companies within the group who operate
from many buildings throughout Europe.”
PaulMattin-EngineeringManager-ImpressManufacturingLtd
The Airius units have allowed
us to increase our thermostats
from 19°C to 23.5°C, resulting in
a saving of over 70% on our
cooling costs.“
“We are very impressed with the results
Airius fans have achieved in our ten pin
bowling centre at Nantgarw in South
Wales. The atmosphere inside has
been greatly improved reducing staff &
customer comfort complaints by 90%.
They have also allowed us to increase our
thermostats from 19°C to 23.5°C resulting
in a saving of over 70% on our cooling
costs. The Airius system has far exceeded
our expectations & will be standard
equipment for all our 18 bowling centres
in the UK.”
Ben Carne – Energy Manager - Bowlplex Plc Ltd
Fans play a key role in recycling
warmer air at high level in the
building back down to lower levels.““All Souls Bolton is a fabulous restoration
of an 18th century gothic revival, grade
II* listed church in Bolton. As with any old
building keeping heating and maintenance
costs low is critically important to our
long term sustainability. The Airius
recycling warmer air at high level in the
building back down to lower levels, keeping
people warmer and at the same time
keeping our heating costs down.”
Andrew Suter - Director - All Souls Bolton
18
The Airius fans made an
immediate ... improvement even
before the heating/cooling system
upgrades had been completed.““Following severe temperature problems
in a British Airways maintenance hangar
at Heathrow, we (Gratte Brothers) were
awarded the contract to upgrade the
heating and ventilation system.
The temperature problems were severe
with staff threatening to walk out. After
exhaustive research it was decided to
install 12 x Airius Model 100 units and
15 x Airius Model 60 units to improve
internal air circulation and reduce the
extremely high heating and cooling costs.
The Airius fans made an immediate and
heating/cooling system upgrades had been
completed.
All complaints from staff ceased
immediately and they were now
comfortable enough to work in their
t-shirts. The team at Airius were really
helpful and a pleasure to work with.
We will be tendering for further British
Airways projects of this type and fully
expect to purchase more Airius units.”
Joe Forgie – Project Manager – Gratte Brothers Group
The Airius units have reduced
our heating costs by an impressive
25% in our sports hall.
““We installed the Airius system into 2
sports halls and the swimming pool area at
Sixmile Leisure Centre, Newtownabbey.
These have made a vast improvement
to the internal atmosphere within the
buildings and the public who use the
improved for sporting activities.
We have found the Airius units have
reduced our heating costs by an impressive
25% in our sports halls and swimming pool
area; the thermostat in the swimming pool
building has also been turned down 2°C!
The heating systems come on much less
often and the complaints from swimmers
about the warmth in the swimming pool
area has reduced by 90%.”
James Dunn – Facilities Manager - Sixmile Leisure Centre
1919
environment comfortable without
the AC running.
““Our Edinburgh Outdoor Experience
opening out into high roofed area with a
We originally controlled the temperature
with large AC units but the result was
never satisfactory at either level.
The Airius system was installed during the
summer whilst the AC system was closed
down for servicing and we were happy to
the AC running. This has now led to the
entire AC system being decommissioned
with a considerable reduction in
electricity consumption.”
Iain Calder – Property Director – Tiso Ltd
Discover more
See our full list of 65+ customer
testimonials on our website at
www.airius.co.uk/client-testimonials
STRATIFICATION IS THE
SINGLE BIGGEST WASTE OF
ENERGY IN BUILDINGS TODAY.
Dr. Byron Jones, phD, MS, BS, ASHRAE
“
DISCOVER OUR CASE STUDIES &
EXPLORE REAL-WORLD GAINS
FROM REAL-WORLD CLIENTS...
>>>>>
CASE STUDY
ImpressFactory Facility, Norfolk
THE FULL COST OF
THE AIRIUS UNITS IS
RECOUPED WITHIN A
MATTER OF MONTHS -
FIRST WINTER SAVINGS
OF £62,351 MEASURED
AGAINST A TOTAL SYSTEM
SPEND OF £21,268.
Paul Matten (Plant Engineer)
• 45.07% - overall savings
08/09
•
savings
• £21,268 - full system &
installation cost
•
• 5.7°C - mean temp. 07/08
• 3.4°C - mean temp. 08/09
• £793 - Airius running costs
per winter season
• Installed into can assembly
area
• System - 34 units
• Part of the Ardagh Group
Key points:
£138,337
£83,837
£54,500
£49,322
£63,144
£793.00
£62,351
Winter Saving Calculations
First Winter Savings
Winter 07/08(pre-fans) total
oil usage
Winter 08/09(post-fans)
total oil usage
Oil use reduction & savings,
winter 08/09
Restated savings, inc lower
Oil price 08/09
Restated Oil use & savings
(inc lower temp) 08/09
Airius System running costs
22
Impress installed 34 Airius fan units
into their factory to save on heating costs and their
investment was repaid 3 times over in the first
winter they were installed.
Oil prices dropped by an average of 9.5% in 08/09
compared to the previous winter period 07/08.
The mean temperature for East Anglia during winter
07/08 was 5.7°C. The mean temperature for East
Anglia during winter 08/09 was much cooler at 3.4°C.
The heating system thermostats are set to 16°C,
resulting in an increase in the requirement for heating
in East Anglia of 22%.
This analysis excludes the purchase and installation
costs of £21,268 in the first year.
Lush CosmeticsManufacturing Facility, Dorset
CASE STUDY
HEATING SPEND
PRE & POST
AIRIUS
Pre Airius
Post Airius
• ROI = 26 DAYS!!
• 61% saving on heating
cost
• Heating spend pre Airius
= £26,638.83
• Heating spend post
Airius = £7,333.38
• £2,967.50 - full system &
installation cost
• £68.75 - Airius system
annual running cost
• Now recirculates process
heat for free heating
Key points:
£10k
£9k
£8k
£7k
£6k
£5k
£4k
£3k
£2k
£1k
Dec ‘11 - ‘12 Feb ‘12 - ‘13Jan ‘12 - ‘13
Net Save post Airius = £19,302.45
2323
Lush Retail Ltd needed to improve internal
conditions at their Hatch Pond Road manufacturing
facility in Poole, Dorset. Temperatures at floor level
were uncomfortably cold as their heating system was
unable to reach acceptable conditions.
This also incurred high energy costs as the heating
system was running constantly in an attempt to reach
set parameters.
Lush Retail Ltd contacted Airius in 2012 in order to
address the uncomfortable low temperatures and
expensive costs for heating at each of their
manufacturing facilities.
The Hatch Pond Road manufacturing facility was
chosen as a trial site due to its high heating costs and
major comfort issues. Originally it was estimated that
this site would benefit from a minimum energy saving
of 35%. However a far greater saving was achieved of
over 60% following installation of the Airius system.
Gama AviationAircraft Hangar, Farnborough
CASE STUDY
Key Points:
• 48.22% saving on heating
costs
• 1,136m³ natural gas
reduction
• Savings account for worst
case scenario and weather
inconsistencies
• Now only one of the two
heating units required to
achieve desired conditions
In 2012 the
temperature was lower
by 0.5o
C in September
and 2.6o
C in October.
A temperature
change of 1o
C can
by between 6-11%,
depending upon
the building. In a
worst case scenario
in 2013 by 5.5% for
September and 28.6%
for October, this takes
and 1,220m³ in September/October 2013.
HEAT & GAS CONSUMPTION
BEFORE & AFTER SYSTEMS
00 500 1000 1500 2000 2500
Heat & Gas in m3
2356m3
1042.30m3
24
Gama Aviation Ltd have two large heating units
in their main engineering hangar at Farnborough
Airport, which would run continuously throughout
the day and never reach the thermostat set point of
14°C. Following installation of the Airius system their
HVAC system would achieve the thermostat set point
with only one of the two heating units running.
Once at the temperature set point, the Airius
system would then continue to maintain the desired
conditions with only the one remaining heating unit
running intermittently.
In September and October of 2012 (PRE AIRIUS) the
heating gas consumption was 2,356m³. In September
and October of 2013 (POST AIRIUS) the heating gas
consumption was 1,042.3m³.
• ROI = Under 18 months
•
saving
• £19,799 – full system
and installation cost
• 1,141, 113 – kWh usage
before Airius
• 709,956 – kWh usage
after Airius
• Installed into acton rail
maintenance shed
• System – 26 Airius
Model 45units
• 75 tonnes – Approx.
annual CO2 reduction
Siemens
CASE STUDY
Key points:
16:00
08:00
00:00
16:00
08:00
00:00
16:00
08:00
00:00
16:00
08:00
00:00
16:00
08:00
00:00
16:00
08:00
00:00
16:00
08:00
00:00
16:00
08:00
00:00
16:00
08:00
00:00
16:00
08:00
00:00
16:00
08:00
00:00
16:00
08:00
00:00
16:00
08:00
00:00
23o
C
22o
C
21o
C
20o
C
19o
C
18o
C
17o
C
16o
C
15o
C
14o
C
TEMPERATURE
READINGS
JAN - FEB ‘12
24|01|1225|01|1226|01|1227|01|1228|01|1229|01|1230|01|1231|01|1201|02|1202|02|1203|02|1204|02|1205|02|12
Ground level Cant Rail levelAirius on
Engineering Facility, Acton
2525
Siemens installed 26 Airius model 45 fan units into
their Acton rail maintenance shed facility to improve
comfort and save on energy costs resulting in an ROI
of less than 18 months.
The graph below shows the temperature differentials
in the Acton rail maintenance shed at both Ground
Level and Cant Rail Level with the Airius system off
during the week 30/01/12 - 05/02/12, and running
during the week 24/01/12 -29/01/12.
Get in touch!
CONTACT US
Airius Europe, Africa,
Middle-East & Asia
Ashley Heath Industrial Estate
Three Legged Cross
Dorset BH21 6UZ, UK
Tel: (00) 1 202 554200
Fax: (00) 1 202 554396
Email: airflow@airius.co.uk
Web: www.airius.co.uk
Airius Americas
811 South Sherman Street
Longmont, Colorado
80501, USA
Tel: (00) 1 888 247 7327
Fax: (00) 1 303 772 8276
Email: info@airiusfans.com
Web: www.airiusfans.com
Airius Oceania
PO Box 6282, Alexandria
NSW 2015
Australia
Tel: (00) 61 0 401 848 888
Email: info@airius.com.au
Web: www.airius.com.au
For more case studies, demonstration videos, client lists,
testimonials and product information visit us at:
www.airius.co.uk
USA and foreign Patents granted to AIRIUS LLC, USA, further patents pending. AIRIUS
& AIRIUS SYSTEMS is the copyright property of AIRIUS LLC, USA. All material issued by,
or emanating from, Airius Europe Ltd is the Copyright property of Airius Europe Ltd , UK.
V2.0
saving you energy
V2.0
saving you energy
USA and foreign Patents granted to AIRIUS LLC, USA, further patents pending. AIRIUS &
AIRIUS SYSTEMS is the copyright property of AIRIUS LLC, USA. All material issued by, or
emanating from, Airius Europe Ltd is the Copyright property of Airius Europe Ltd , UK.

Weitere ähnliche Inhalte

Was ist angesagt?

Thermon Industrial Hazardous Area Trace Heating - General Information
Thermon Industrial Hazardous Area Trace Heating - General InformationThermon Industrial Hazardous Area Trace Heating - General Information
Thermon Industrial Hazardous Area Trace Heating - General Information
Thorne & Derrick UK
 
Thermodynamics 1st law - presentation
Thermodynamics  1st law - presentationThermodynamics  1st law - presentation
Thermodynamics 1st law - presentation
Scholenberg international
 
AHS-SS-Product-Brochure-Single-Web-V3
AHS-SS-Product-Brochure-Single-Web-V3AHS-SS-Product-Brochure-Single-Web-V3
AHS-SS-Product-Brochure-Single-Web-V3
Peter Adams
 
General Sales Brochure 2016
General Sales Brochure 2016General Sales Brochure 2016
General Sales Brochure 2016
Alan Beresford
 
EcoCooling IT Sales Manual
EcoCooling IT Sales ManualEcoCooling IT Sales Manual
EcoCooling IT Sales Manual
Alan Beresford
 
Project Zephyr Final Presentation (Low Res)
Project Zephyr Final Presentation (Low Res)Project Zephyr Final Presentation (Low Res)
Project Zephyr Final Presentation (Low Res)
Tyson Rose
 

Was ist angesagt? (20)

Winterisation - Arctic Offshore & Maritime Heating Solutions - Thermon Heat T...
Winterisation - Arctic Offshore & Maritime Heating Solutions - Thermon Heat T...Winterisation - Arctic Offshore & Maritime Heating Solutions - Thermon Heat T...
Winterisation - Arctic Offshore & Maritime Heating Solutions - Thermon Heat T...
 
Fire, Pressure & Ice – Oh My! Motion Control in Hostile Environments
Fire, Pressure & Ice – Oh My! Motion Control in Hostile EnvironmentsFire, Pressure & Ice – Oh My! Motion Control in Hostile Environments
Fire, Pressure & Ice – Oh My! Motion Control in Hostile Environments
 
Thermon Industrial Hazardous Area Trace Heating - General Information
Thermon Industrial Hazardous Area Trace Heating - General InformationThermon Industrial Hazardous Area Trace Heating - General Information
Thermon Industrial Hazardous Area Trace Heating - General Information
 
A facilities managers guide to achieving adaptive thermal comfort for occupants
A facilities managers guide to achieving adaptive thermal comfort for occupantsA facilities managers guide to achieving adaptive thermal comfort for occupants
A facilities managers guide to achieving adaptive thermal comfort for occupants
 
Residential hvac system
Residential hvac systemResidential hvac system
Residential hvac system
 
Thermodynamics 1st law - presentation
Thermodynamics  1st law - presentationThermodynamics  1st law - presentation
Thermodynamics 1st law - presentation
 
Latest trends in hvac system
Latest trends in hvac systemLatest trends in hvac system
Latest trends in hvac system
 
The Internet Of Things (IoT) Enabled by Resourceful Data Centre Thermal Mana...
The Internet Of Things (IoT) Enabled by Resourceful Data Centre Thermal Mana...The Internet Of Things (IoT) Enabled by Resourceful Data Centre Thermal Mana...
The Internet Of Things (IoT) Enabled by Resourceful Data Centre Thermal Mana...
 
The Money-Saving Survival Guide: AC, Heating, and Air Quality
The Money-Saving Survival Guide: AC, Heating, and Air QualityThe Money-Saving Survival Guide: AC, Heating, and Air Quality
The Money-Saving Survival Guide: AC, Heating, and Air Quality
 
Air conditioning if its not clean - its not green - ACT smart 4th sept 2014
Air conditioning   if its not clean - its not green - ACT smart 4th sept 2014Air conditioning   if its not clean - its not green - ACT smart 4th sept 2014
Air conditioning if its not clean - its not green - ACT smart 4th sept 2014
 
AHS-SS-Product-Brochure-Single-Web-V3
AHS-SS-Product-Brochure-Single-Web-V3AHS-SS-Product-Brochure-Single-Web-V3
AHS-SS-Product-Brochure-Single-Web-V3
 
HVAC Control Systems— Get it Right the First Time! (Part 3)
HVAC Control Systems— Get it Right the First Time! (Part 3)HVAC Control Systems— Get it Right the First Time! (Part 3)
HVAC Control Systems— Get it Right the First Time! (Part 3)
 
General Sales Brochure 2016
General Sales Brochure 2016General Sales Brochure 2016
General Sales Brochure 2016
 
Hvac systems presentation_slides
Hvac systems presentation_slidesHvac systems presentation_slides
Hvac systems presentation_slides
 
Airius Poultry Shed Destratification System Brochure
Airius Poultry Shed Destratification System BrochureAirius Poultry Shed Destratification System Brochure
Airius Poultry Shed Destratification System Brochure
 
Hvac Ppt
Hvac PptHvac Ppt
Hvac Ppt
 
Ian tuena (2) natural refrigerants presentation april 2016
Ian tuena (2) natural refrigerants presentation april 2016Ian tuena (2) natural refrigerants presentation april 2016
Ian tuena (2) natural refrigerants presentation april 2016
 
CAREL Hecu Sistema - The REAL capacity modulation for C-Stores
CAREL Hecu Sistema - The REAL capacity modulation for C-StoresCAREL Hecu Sistema - The REAL capacity modulation for C-Stores
CAREL Hecu Sistema - The REAL capacity modulation for C-Stores
 
EcoCooling IT Sales Manual
EcoCooling IT Sales ManualEcoCooling IT Sales Manual
EcoCooling IT Sales Manual
 
Project Zephyr Final Presentation (Low Res)
Project Zephyr Final Presentation (Low Res)Project Zephyr Final Presentation (Low Res)
Project Zephyr Final Presentation (Low Res)
 

Andere mochten auch

Andere mochten auch (6)

Should Your Clients Be Podcasting?
Should Your Clients Be Podcasting?Should Your Clients Be Podcasting?
Should Your Clients Be Podcasting?
 
Olon ulsiin huviin erh zuin barimt bichigiin emhetgel 2004
Olon ulsiin huviin erh zuin barimt bichigiin emhetgel 2004Olon ulsiin huviin erh zuin barimt bichigiin emhetgel 2004
Olon ulsiin huviin erh zuin barimt bichigiin emhetgel 2004
 
Presentation
PresentationPresentation
Presentation
 
Precision Iceblast Corporation-Dry Ice (CO2) Blasting
Precision Iceblast Corporation-Dry Ice (CO2) Blasting Precision Iceblast Corporation-Dry Ice (CO2) Blasting
Precision Iceblast Corporation-Dry Ice (CO2) Blasting
 
Investor Group Brochure
Investor  Group  BrochureInvestor  Group  Brochure
Investor Group Brochure
 
TV Comedy: US Sitcoms
TV Comedy: US SitcomsTV Comedy: US Sitcoms
TV Comedy: US Sitcoms
 

Ähnlich wie Airius Brochure - V2.0 - Low Res

Afcom air control solution presentation
Afcom air control solution presentation Afcom air control solution presentation
Afcom air control solution presentation
stacygriggs
 
Dimplex Air Curtain, Air Heaters, Radiant Heaters & Fan Heaters - Brochure
Dimplex Air Curtain, Air Heaters, Radiant Heaters & Fan Heaters - BrochureDimplex Air Curtain, Air Heaters, Radiant Heaters & Fan Heaters - Brochure
Dimplex Air Curtain, Air Heaters, Radiant Heaters & Fan Heaters - Brochure
Thorne & Derrick UK
 
General Sales Brochure 2016
General Sales Brochure 2016General Sales Brochure 2016
General Sales Brochure 2016
Emma Beresford
 
ClimateWizard_ReferenceBook_AUS_CW042_REVE_0615_proof
ClimateWizard_ReferenceBook_AUS_CW042_REVE_0615_proofClimateWizard_ReferenceBook_AUS_CW042_REVE_0615_proof
ClimateWizard_ReferenceBook_AUS_CW042_REVE_0615_proof
Hennie Verster
 
ClimateWizard_Brochure_AUS_CW005_REVE_0515 NEW
ClimateWizard_Brochure_AUS_CW005_REVE_0515 NEWClimateWizard_Brochure_AUS_CW005_REVE_0515 NEW
ClimateWizard_Brochure_AUS_CW005_REVE_0515 NEW
Hennie Verster
 
Airius Sales Training Presentation
Airius Sales Training PresentationAirius Sales Training Presentation
Airius Sales Training Presentation
airius
 
building services
building servicesbuilding services
building services
szelun
 

Ähnlich wie Airius Brochure - V2.0 - Low Res (20)

Tawada CleanTech - Solution for Better Indoor Air Quality
Tawada CleanTech - Solution for Better Indoor Air QualityTawada CleanTech - Solution for Better Indoor Air Quality
Tawada CleanTech - Solution for Better Indoor Air Quality
 
Types of air conditioning for HVAC application
Types of air conditioning for HVAC applicationTypes of air conditioning for HVAC application
Types of air conditioning for HVAC application
 
Aviation application-brochure
Aviation application-brochureAviation application-brochure
Aviation application-brochure
 
Afcom air control solution presentation
Afcom air control solution presentation Afcom air control solution presentation
Afcom air control solution presentation
 
alturascontractors.com-Ways to Extend the Life of an HVAC System.pdf
alturascontractors.com-Ways to Extend the Life of an HVAC System.pdfalturascontractors.com-Ways to Extend the Life of an HVAC System.pdf
alturascontractors.com-Ways to Extend the Life of an HVAC System.pdf
 
Dimplex Air Curtain, Air Heaters, Radiant Heaters & Fan Heaters - Brochure
Dimplex Air Curtain, Air Heaters, Radiant Heaters & Fan Heaters - BrochureDimplex Air Curtain, Air Heaters, Radiant Heaters & Fan Heaters - Brochure
Dimplex Air Curtain, Air Heaters, Radiant Heaters & Fan Heaters - Brochure
 
General Sales Brochure 2016
General Sales Brochure 2016General Sales Brochure 2016
General Sales Brochure 2016
 
ClimateWizard_ReferenceBook_AUS_CW042_REVE_0615_proof
ClimateWizard_ReferenceBook_AUS_CW042_REVE_0615_proofClimateWizard_ReferenceBook_AUS_CW042_REVE_0615_proof
ClimateWizard_ReferenceBook_AUS_CW042_REVE_0615_proof
 
ClimateWizard_Brochure_AUS_CW005_REVE_0515 NEW
ClimateWizard_Brochure_AUS_CW005_REVE_0515 NEWClimateWizard_Brochure_AUS_CW005_REVE_0515 NEW
ClimateWizard_Brochure_AUS_CW005_REVE_0515 NEW
 
Datacentre Uk
Datacentre UkDatacentre Uk
Datacentre Uk
 
Airius Sales Training Presentation
Airius Sales Training PresentationAirius Sales Training Presentation
Airius Sales Training Presentation
 
Techfest
TechfestTechfest
Techfest
 
Daikin applied vrv brochure
Daikin applied vrv brochureDaikin applied vrv brochure
Daikin applied vrv brochure
 
building services
building servicesbuilding services
building services
 
Building Services - Efficient Energy Ventilation System
Building Services - Efficient Energy Ventilation SystemBuilding Services - Efficient Energy Ventilation System
Building Services - Efficient Energy Ventilation System
 
Tim edwards (2) the hvacr supply chain 3
Tim edwards (2) the hvacr supply chain 3Tim edwards (2) the hvacr supply chain 3
Tim edwards (2) the hvacr supply chain 3
 
Tim edwards (2) the hvacr supply chain 3
Tim edwards (2) the hvacr supply chain 3Tim edwards (2) the hvacr supply chain 3
Tim edwards (2) the hvacr supply chain 3
 
Retail Application-Airius
Retail Application-AiriusRetail Application-Airius
Retail Application-Airius
 
Airius and Local Authorities
Airius and Local AuthoritiesAirius and Local Authorities
Airius and Local Authorities
 
Mechanical systems
Mechanical systemsMechanical systems
Mechanical systems
 

Airius Brochure - V2.0 - Low Res

  • 1. saving you energy Save 20-50% on heating & cooling costs with Airius Destratification Visit us atwww.airius.co.uk Recommended by The Carbon Trust* SAVE ENERGY, CUT COSTS, REDUCE CARBON EMISSIONS saving you energy Save 20-50% on heating & cooling costs with Airius Destratification Recommended by The Carbon Trust* SAVE ENERGY, CUT COSTS, REDUCE CARBON EMISSIONS Visit us atwww.airius.co.uk
  • 2. ©2015 AIRIUS Europe Ltd. USA and Foreign Patents Pending. AIRIUS® * Airius has helped thousands of businesses, from SMEs to major Blue Chip companies make real reductions in their energy usage and carbon emissions.
  • 3. 04. 06. 08. 10. 12. 14. 15. 16. 20. 22. 25. Installation process Patented Stator Technology How does it work? USPs FAQs Our product range The Standard Series All-inclusive features The Designer Series The discreet solution System Speed Controls Variable on/off speed controls The Suspended Series Suspended ceiling integration Assured quality Testimonials Project gallery Case studies Contact information Table of Contents TRUST IN AIRIUS 18. Formed in 2004, we have revolutionised the industry with our market leading thermal destratification systems, which have helped balance the internal temperatures in public and commercial buildings all across the world. As testament to the efficiency of the Airius system, we have quickly built up an extensive and prestigious client base including well-known brands like Boots, British Airways, Mercedes, Morrisons and many more.
  • 4. 4 Recommended by the Carbon Trust, Destratification systems are one of the most effective energy reduction technologies available on the market.[ Installation process installed into new or existing builds and have been installed into Grade I, II* and II listed buildings for numerous clients. The installation process is very simple and can be installed in a short space of time. The difference will be instantly noticeable and will improve the comfort levels in your building. Tphenomenon that affects all buildings and results in a dramatic phenomenon occurs when hot air rises towards the ceiling or roof, as it is lighter than the surrounding cool air. In contrast, The main negative consequence of Ventilation and Air Conditioning (HVAC) systems in your building will be working in overdrive to maintain set temperatures at HVAC systems which are constantly overdelivering will be costing your in performance and lost energy. There will also be a negative impact on your company’s carbon footprint. Wasted heat will inevitably rise and accumulate at the ceiling of your building, (0.5ºC – 2ºC per metre on average). Conversely, heavier cooled air which is by sinking to low points in a building or circulate areas. What will Airius do? To combat the problem of thermal will balance internal temperatures, by recycling the heated or cooled air supplied or accumulated from people, processes or solar gain, and circulating temperatures fully throughout your entire building. Our systems will also reduce the operation time and workload required of heating and cooling systems. The difference will be instantly noticeable, improving not just comfort levels in your building but also the therefore maximising savings. Installation process
  • 5. Patented Stator Technology RECOMMENDED BY THE CARBON TRUST • Reduces heating costs by 30% - 50% • Reduces cooling costs by 20% - 40% • Maintains optimum working / retail environment • Reduces CO2 emissions by 20% - 50% • Rapid ROI - usually between 12 - 24 months • 3 year warranty • Customers include FTSE100 companies to SMEs • Eligible for carbon reducing grants / loans • Established and proven technology • Increases lighting lifespan • Minimal maintenance required • Minimal running costs (from £6/pa) • Recycles heat from machinery, lighting, solar gain etc • Reduces condensation • Reduces wear on existing HVAC equipment • Simple to install with no ducting required • ESOS / CRC Solution • Small, versatile, unobtrusive units • Stand alone or BMS integrated • Works alongside all types of HVAC systems 55 With any fan, the spinning blades induce a rotational component into the air stream causing turbulence and reduced throw distance. Airius’ patented multi-vane stator technology transfers this rotational energy to create an invisible column of air (columnar laminar flow), increasing throw distance. This is a standard feature on all Airius ranges. With the Airius systems’ patented multi- vane stator technology, temperatures are balanced to within 1°C - 2°C.
  • 6. How does it work? Discover how Airius’ market leading features and benefits compare to the competition, offering the most cost effective destratification solution available.[ O The Airius ceiling-mounted axial turbine fan Pros 20 - 50% energy savings | 1ºC - 2ºC temperature variance | Low energy consumption (12W+) | Silent operation | Lightweight, small and unobtrusive | Avoids draught disturbance | Simple installation | BSRIA tested | Cons Roof level installation. Unit Cost Running Cost Figures above are based upon equivalent systems: ¹Powrmatic CEC 3750, ²Ambirad/Benson DS10 & ³Airius Model 60. £500 5,000kWh 15,000kWh 25,000kWh 35,000kWh £1,500 £2,500 £3,500 Leading wall Box Fan1 Leading ceiling Box Fan2 Airius Range3 6 40m 12m 8.5m These are installed at ceiling height, sending air to the floor in a slow-moving column. This uses low levels of power, pushing air through a very small space. Once it reaches floor level, the airflow blankets out in all directions before rising and being recirculated through the fan. Ultra quiet with minimal air movement, ideal for noise-sensitive environments. Savings on average between 20 - 50%, although higher levels have been recorded (see Lush Cosmetics Case Study, page 23).
  • 7. 77 The ‘blade’ or paddle fan Pros 5 - 10% energy savings | Low energy consumption. Cons Temperature variance 8ºC - 12ºC | Roof level Installation | spread disperses before 40m 12m 8.5m The wall-mounted box fan height and angled upwards. They send air at high velocity upwards to push warm air gathered at the ceiling Pros 10 - 15% energy savings – Although this is offset against high running costs | Low Level Installation. Cons Temperature variance 8ºC - 12ºC | Noisy | High energy usage – 450kWh+ | Large, heavy units – Average 35kg to 95kg | Recommended installation at head height, which can cause accident and injury. 40m 12m 8.5m The ceiling-mounted box fan and send high velocity air directly problems and can pick up and circulate dust particles. They are also high energy consumers and not suitable for noise sensitive environments. Pros 5 - 10% energy savings – Although this is offset against high running costs. Cons Temperature variance 5ºC - 10ºC | Noisy | High energy usage – 450kWh+ | Large, heavy units – Average 35kg to 95kg | Roof level installation. 40m 12m 8.5m Overhead ducted fans Installed at ceiling height sending required to overcome the friction of to circulate and instead immediately rises back to the ceiling. Installation of the ducting is also expensive and time-consuming, causing extended disruption to a building’s normal operation. Pros 5 - 10% energy savings. Cons Localised temperature variance 4ºC - 8ºC near exhausts | | Poor | Floor plans must be adapted placing work stations near duct exhausts | Ducting and its installation is expensive and disruptive | Extensive high and low level ducting installation. 40m 12m 8.5m The cheapest option, works by ‘churning’ the air. However, it is not organised and the airflow disperses before it can reach the floor (see smoke test video at (www.airius.co.uk).
  • 8. FAQs [ W hat is the typical rate of to ceiling? of 0.5 –2ºC per metre and temperature differentials of up to 10°C are common over a height of 10 metres. In extreme cases, temperature differentials of 10°C have been found over a height of 3 metres. a number of factors such as the building materials, level of insulation, activity in the building, heating/cooling set points and the outside temperature. It is wrong to assume that if the level of scale there is not much to be gained. This can be down to a number of reasons, such as: • Insulation levels are so low, heat escapes before it can build up. Our best case studies have been from buildings like this • Outside temperature is at or above room temperature • The heating is off When do you start saving? Immediately! The moment the units building and HVAC system will start to improve, reaching their full potential once equalisation is achieved (within 48 hours depending on the size of the building). How much can I expect to save on heating? Savings range hugely from building to building with average savings of 30 – 50%. With over 100,000 units sold, we have had reported savings ranging from 20% to 76%. This is down to a number of factors, such as: • Ceiling Height • Insulation • Achieving Temperature • Levels of Process / Ambient heat How does the Airius system work with cooling? The way Airius units work to reduce cooling costs is slightly different to heating. Typically in cooled spaces, people near the cooling outlet are too cold and those no more than a few metres away are too hot. People by windows can also get too hot due to solar gain and so on. The Airius units help by equalising the temperature making sure that everyone possible. It also helps the cool air reach thermostat set points quicker. The Airius system also ensures that every cubic metre of air in the building is moving very slowly. This gentle air movement across the skin creates a lower perceived temperature (evaporative cooling), allowing you to turn your thermostat up by between 2ºC and 4ºC, yet maintain the same conditions or better for occupants. > 8 Discover the true potential and value of Destratification, as we answer some of the key and frequently asked questions set by our clients.
  • 9. 9 happily carry out a full site survey free of Call: +44 (0)1202 554 200 Email: FREE SITE SURVEY SUPPLIED £11.56 £14.45 £29.87 £40.47 £120.45 £168.63 £115.63 £163.81 £375.80 £385.44 MODEL NUMBER Model 10 Model 15 Model 25 Model 45/PS-4 Model 45/PS-2 Model 45/EC Model 60/PS-4 Model 60/EC Model 100/EC Model 125/EL 12 Watts 15 Watts 31 Watts 42 Watts 125 Watts 175 Watts 120 Watts 170 Watts 390 Watts 400 Watts POWER CONSUMPTION ANNUAL RUNNING COST How much do Airius units cost to run? electrical load, using less than 5% of the power of running costs, based on the units running 24 hours a day, 365 days a year, at an electrical cost of 11 pence per kWh. WE ARE VERY IMPRESSED WITH THE AIRIUS FANS IN OUR BOWLING CENTRE AT NANTGARW. WE’VE NOW INCREASED OUR THERMOSTATS FROM 19°C TO 23.5°C RESULTING IN A SAVING OF OVER 70% ON OUR COOLING COSTS! Bowlplex PLC “ THE AIRIUS SYSTEM WAS INSTALLED DURING THE SUMMER WHILST THE AC SYSTEM WAS CLOSED DOWN FOR SERVICING AND WE WERE HAPPY TO FIND THE ENVIRONMENT NOW COMFORTABLE WITHOUT THE AC RUNNING. Tiso Ltd “ This along with the equalised temperature has proven to reduce cooling costs from 20% up to 100%. This is due to the low cooling requirement in the UK. You only need to reduce the cooling load slightly to make huge savings. 9
  • 10. 4m - 6m 9m - 11m 60m² - 90m² 230 15 1230 406 690 0.06 0 - 21dB(A) 6.5m - 8m 11m - 13m 89m² - 133m² 230 31 1450 459 780 0.14 0 - 31dB(A) 8.5m - 14m 11m - 13m 89m² - 133m² 230 42 1450 595 1010 0.19 0 - 35dB(A) 2.5m - 3.5m 8m - 10m 48m² - 72m² 230 12 980 318 540 0.06 0 - 21dB(A) Our product range Explore the most versatile and efficient destratification fans available, which ensure temperatures provided by heating and cooling are maintained efficiently throughout internal spaces.[ Airius units are available as free hanging fans applicable for ceiling heights from 2.5m to 40m, or can be installed into suspended ceilings up to 15m high with our 600mm x 600mm Suspended Series kit (see page 14).” Tech Specs Model 10 Model 15 Model 25 Ceiling Heights Dia. Coverage Floor Area Coverage Volts¹ RPM @ 50 Hz¹ CFM @ 50 Hz¹ m³/hr¹ AMPS @ 50 Hz¹ Noise Level² Model 10 Height: 444mm Rim height: 311mm Width: 325mm Weight: 3.2kg Model 15 Height: 546mm Rim height: 413mm Width: 325mm Weight: 4.1kg Model 25 Height: 546mm Rim Height: 413mm Width: 325mm Weight: 4.1kg Model 45 Height: 605mm Rim height: 455mm Width: 375mm Weight: 6.3kg Model 60 Height: 823mm Rim height: 607mm Width: 498mm Weight: 9.9kg Model 100 Height: 843mm Width: 495mm Weight: 20.4kg Standard Series ¹Motor data provided by motor manufacturer and is subject to change at any time. Data above is calculated at 50Hz. Model 45/PS-4 10
  • 11. 15m - 20m 14m - 17m 148m² - 222m² 230 120 1390 1667 2832 0.57 0 - 38dB(A) 17m - 22m 14m - 17m 155m² - 232m² 230 170 1630 1770 3007 1.30 0 - 38dB(A) 20m - 33m 15m - 19m 186m² - 279m² 230 390 1690 3358 5705 2.50 0 - 34dB(A) 12m - 15m 11m - 14m 100m² - 150m² 230 125 2450 1072 1821 0.54 0 - 44dB(A) 13m - 16m 12m - 15m 111m² - 167m² 230 175 3050 1290 2192 1.40 0 - 49dB(A) supplier to specify your system. Model 45/PS-2 Model 45/EC Model 60/PS-4 Model 60/EC Model 100 Model 125 Model 125 Height: 938mm Width: 690mm Weight: 45.3kg Model 60 Height: 838mm Rim height: 610mm Width: 492mm Weight: 17.2kg Model 45 Height: 610mm Rim height: 452mm Width: 373mm Weight: 8.6kg Model 25 Height: 538mm Rim height: 400mm Width: 333mm Weight: 6.8kg Model 15 Height: 538mm Rim height: 400mm Width: 333mm Weight: 6.8kg Designer Series Series warranty Warranty. Simply return defective units to Airius, carriage paid and upon receipt Airius will dispatch a new unit by return carriage fully paid. To avoid refurbishment and cleaning charges, all units returned must adhere to the returns criteria. www.airius.co.uk/airius-warranty- terms-conditions 1111 20m - 40m 17m - 21m 223m² - 334m² 200-277 400 1000 5200 8835 1.80 0 - 31dB(A) Model 10 Height: 436mm Rim height: 299mm Width: 333mm Weight: 5.4kg
  • 12. Standard Series F irst released in 2004, The Airius Standard Series throughout the world. The Airius Standard Series is available in several models with various motor and control options available to accommodate your building’s unique All models in the Standard Series range feature motors, which are suspended just below ceiling height in your building. This series is suitable for buildings with a ceiling height of 2.5 metres, right up to 33 metres. From the short Model 10 to the Model 100, the Standard Series range is capable of equalising per fan. All products in the Standard Series are supplied in an off-white colour. However, if requested we have the facilities to custom paint your code. Call Airius today to receive a personalised quotation for your company. [ Since its first release in 2004, the Airius Standard Series has been the go-to free hanging fan, used to combat thermal stratification in buildings across the world. Call Airius today to receive a fully tailored quotation for your building. +44 (0)1202 554 200 O 12
  • 13. Leash anchor The leash anchor point is another standard feature on all Airius when fully installed. All-inclusive features Adaptability Adaptable bail and eye bolts allow easy be angled 90o and 360o horizontally (see website for guides). Cord length 1.5 metre cord length as standard, which can be wired onto a circuit or powered standalone plug (not supplied). Ultra quiet All Airius fans are ultra-quiet and can environments such as and even libraries. STANDARD s e r i e s 1313
  • 14. +44 (0)1202 554 200 Designer Series [ T he Airius Designer Series shares many similarities to our Standard Series and will provide your building with all of However, models from the Designer Series are enclosed in a powder coated aluminium cylindrical housing and are perfectly suited to architecturally sensitive installations. All models in the Designer Series operate in exactly the same manner as models from the Standard Series. We can customise the Designer Series with motor and control options to suit your paint the units to match any RAL colour code. The Designer Series is suitable for installation in properties with ceiling heights ranging from 2.5 metres, right up to 40m high. Contact our team today for a personalised quotation. The Airius Designer Series provides you with a solution to suit any building, blending in with environments effortlessly without taking on the appearance of a typical fan. The discreet solution Save energy in style and specify the Airius Designer Series, which is enclosed in an aluminium cylindrical housing and can be tailored to any custom colour. 14
  • 15. 1 Amp Controller The 1 Amp Controller suitable for: • 16 x Airius Model 10’s • 13 x Airius Model 15’s • 6 x Airius Model 25’s • 4 x Airius Model 45/PS-4’s • 1 x Airius Model 45/PS-2 • 1 x Airius Model 60/PS-4 All Airius systems are designed to operate on a 24/7 basis for maximum Our speed controllers feature a speed control dial that is easy to operate and install in onto circuits of the same Airius model. Airius supplies the following types of speed controllers: System Speed Controls 5 Amp Controller The 5 Amp Controller suitable for: • 83 x Airius Model 10’s • 66 x Airius Model 15’s • 32 x Airius Model 25’s • 23 x Airius Model 45/PS-4’s • 8 x Airius Model 45/PS-2’s • 8 x Airius Model 60/PS-4’s EC Controller The EC controller is suitable for Airius EC and EL models only. DESIGNER s e r i e s Log on to the Airius website and discover for your business. www.airius.co.uk Or call: +44 (0)1202 554 200 1515
  • 16. Suspended Series [ T he Airius Suspended Series is suitable for buildings with dropped, false or suspended ceilings or where an unobtrusive and discreet installation is required. Thermal many buildings, not only in the UK but all around the world and is a leading contributor to high energy costs and increased carbon footprints. The Airius Suspended Series will ensure that there is a constant recirculation of air and balance temperatures throughout your building, saving you 20% to 50% on your heating/cooling costs and reducing your carbon footprint considerably. The Airius Suspended Series is an additional piece of equipment that houses an Airius Standard Series from just below the ceiling before it escapes into the void above. Suitable for buildings with a ceiling height of 2.5 metres up to 15 metres, the Suspended Series is simple to install meeting standard European ceiling grid dimensions (600mm x 600mm) and is easily adaptable to changing All models in the Suspended Series are available in off-white or can also be custom painted to match any RAL colour code. For installations into suspended, dropped or false ceilings Airius supply a suspended ceiling kit, which is sized to fit standard European ceiling tile dimensions. Email Airius today, complete with your details & site reference for a 24hr reply. Or call: +44 (0)1202 554 200 16
  • 17. 17 Suspended ceiling integration SUSPENDED s e r i e s Weight & dimensions Note: Standard Series fan nozzles will lengths depending upon the model. See below: Model 10 (Short) = 120mm Model 10, 15 & 25 = 222mm Model 45 = 219mm Weight = 3.6kgs (*4kgs) | Ceiling Height = 2.5m - 15m | | ) Min ceiling void required 400mm (*460mm) 267mm (*335mm) 413mm 600mm 600mm 57mm 1717 DOME FACE PLATE *Applies to Model 45 (8.5m - 16m) Suspended Series Kit To accommodate the Suspended Series and to allow working space for installation we recommend a minimum ceiling void of 400mm (460mm for Model 45 Suspended Series), however customers have been able to install the Suspended Series into a void as little as 300mm.
  • 18. Assured quality Airius Destratification fans have been installed into many commercial, private, public and government buildings. Discover who we work with and what they have to say.[ Customer testimonials First winter savings of £62,251 measured against a total system spend of £21,268! ““We installed 34 Airius units into the assembly plant at our manufacturing site and I am very pleased with the results. The heating system now comes on far less and employees who work in this building are much warmer. Overall savings equaled 45.07%. The full cost of the Airius units is recouped within a matter of months - against a total system spend of £21,268! I will be looking at other buildings on our site and recommending Airius to companies within the group who operate from many buildings throughout Europe.” PaulMattin-EngineeringManager-ImpressManufacturingLtd The Airius units have allowed us to increase our thermostats from 19°C to 23.5°C, resulting in a saving of over 70% on our cooling costs.“ “We are very impressed with the results Airius fans have achieved in our ten pin bowling centre at Nantgarw in South Wales. The atmosphere inside has been greatly improved reducing staff & customer comfort complaints by 90%. They have also allowed us to increase our thermostats from 19°C to 23.5°C resulting in a saving of over 70% on our cooling costs. The Airius system has far exceeded our expectations & will be standard equipment for all our 18 bowling centres in the UK.” Ben Carne – Energy Manager - Bowlplex Plc Ltd Fans play a key role in recycling warmer air at high level in the building back down to lower levels.““All Souls Bolton is a fabulous restoration of an 18th century gothic revival, grade II* listed church in Bolton. As with any old building keeping heating and maintenance costs low is critically important to our long term sustainability. The Airius recycling warmer air at high level in the building back down to lower levels, keeping people warmer and at the same time keeping our heating costs down.” Andrew Suter - Director - All Souls Bolton 18
  • 19. The Airius fans made an immediate ... improvement even before the heating/cooling system upgrades had been completed.““Following severe temperature problems in a British Airways maintenance hangar at Heathrow, we (Gratte Brothers) were awarded the contract to upgrade the heating and ventilation system. The temperature problems were severe with staff threatening to walk out. After exhaustive research it was decided to install 12 x Airius Model 100 units and 15 x Airius Model 60 units to improve internal air circulation and reduce the extremely high heating and cooling costs. The Airius fans made an immediate and heating/cooling system upgrades had been completed. All complaints from staff ceased immediately and they were now comfortable enough to work in their t-shirts. The team at Airius were really helpful and a pleasure to work with. We will be tendering for further British Airways projects of this type and fully expect to purchase more Airius units.” Joe Forgie – Project Manager – Gratte Brothers Group The Airius units have reduced our heating costs by an impressive 25% in our sports hall. ““We installed the Airius system into 2 sports halls and the swimming pool area at Sixmile Leisure Centre, Newtownabbey. These have made a vast improvement to the internal atmosphere within the buildings and the public who use the improved for sporting activities. We have found the Airius units have reduced our heating costs by an impressive 25% in our sports halls and swimming pool area; the thermostat in the swimming pool building has also been turned down 2°C! The heating systems come on much less often and the complaints from swimmers about the warmth in the swimming pool area has reduced by 90%.” James Dunn – Facilities Manager - Sixmile Leisure Centre 1919 environment comfortable without the AC running. ““Our Edinburgh Outdoor Experience opening out into high roofed area with a We originally controlled the temperature with large AC units but the result was never satisfactory at either level. The Airius system was installed during the summer whilst the AC system was closed down for servicing and we were happy to the AC running. This has now led to the entire AC system being decommissioned with a considerable reduction in electricity consumption.” Iain Calder – Property Director – Tiso Ltd Discover more See our full list of 65+ customer testimonials on our website at www.airius.co.uk/client-testimonials
  • 20. STRATIFICATION IS THE SINGLE BIGGEST WASTE OF ENERGY IN BUILDINGS TODAY. Dr. Byron Jones, phD, MS, BS, ASHRAE “
  • 21. DISCOVER OUR CASE STUDIES & EXPLORE REAL-WORLD GAINS FROM REAL-WORLD CLIENTS... >>>>>
  • 22. CASE STUDY ImpressFactory Facility, Norfolk THE FULL COST OF THE AIRIUS UNITS IS RECOUPED WITHIN A MATTER OF MONTHS - FIRST WINTER SAVINGS OF £62,351 MEASURED AGAINST A TOTAL SYSTEM SPEND OF £21,268. Paul Matten (Plant Engineer) • 45.07% - overall savings 08/09 • savings • £21,268 - full system & installation cost • • 5.7°C - mean temp. 07/08 • 3.4°C - mean temp. 08/09 • £793 - Airius running costs per winter season • Installed into can assembly area • System - 34 units • Part of the Ardagh Group Key points: £138,337 £83,837 £54,500 £49,322 £63,144 £793.00 £62,351 Winter Saving Calculations First Winter Savings Winter 07/08(pre-fans) total oil usage Winter 08/09(post-fans) total oil usage Oil use reduction & savings, winter 08/09 Restated savings, inc lower Oil price 08/09 Restated Oil use & savings (inc lower temp) 08/09 Airius System running costs 22 Impress installed 34 Airius fan units into their factory to save on heating costs and their investment was repaid 3 times over in the first winter they were installed. Oil prices dropped by an average of 9.5% in 08/09 compared to the previous winter period 07/08. The mean temperature for East Anglia during winter 07/08 was 5.7°C. The mean temperature for East Anglia during winter 08/09 was much cooler at 3.4°C. The heating system thermostats are set to 16°C, resulting in an increase in the requirement for heating in East Anglia of 22%. This analysis excludes the purchase and installation costs of £21,268 in the first year.
  • 23. Lush CosmeticsManufacturing Facility, Dorset CASE STUDY HEATING SPEND PRE & POST AIRIUS Pre Airius Post Airius • ROI = 26 DAYS!! • 61% saving on heating cost • Heating spend pre Airius = £26,638.83 • Heating spend post Airius = £7,333.38 • £2,967.50 - full system & installation cost • £68.75 - Airius system annual running cost • Now recirculates process heat for free heating Key points: £10k £9k £8k £7k £6k £5k £4k £3k £2k £1k Dec ‘11 - ‘12 Feb ‘12 - ‘13Jan ‘12 - ‘13 Net Save post Airius = £19,302.45 2323 Lush Retail Ltd needed to improve internal conditions at their Hatch Pond Road manufacturing facility in Poole, Dorset. Temperatures at floor level were uncomfortably cold as their heating system was unable to reach acceptable conditions. This also incurred high energy costs as the heating system was running constantly in an attempt to reach set parameters. Lush Retail Ltd contacted Airius in 2012 in order to address the uncomfortable low temperatures and expensive costs for heating at each of their manufacturing facilities. The Hatch Pond Road manufacturing facility was chosen as a trial site due to its high heating costs and major comfort issues. Originally it was estimated that this site would benefit from a minimum energy saving of 35%. However a far greater saving was achieved of over 60% following installation of the Airius system.
  • 24. Gama AviationAircraft Hangar, Farnborough CASE STUDY Key Points: • 48.22% saving on heating costs • 1,136m³ natural gas reduction • Savings account for worst case scenario and weather inconsistencies • Now only one of the two heating units required to achieve desired conditions In 2012 the temperature was lower by 0.5o C in September and 2.6o C in October. A temperature change of 1o C can by between 6-11%, depending upon the building. In a worst case scenario in 2013 by 5.5% for September and 28.6% for October, this takes and 1,220m³ in September/October 2013. HEAT & GAS CONSUMPTION BEFORE & AFTER SYSTEMS 00 500 1000 1500 2000 2500 Heat & Gas in m3 2356m3 1042.30m3 24 Gama Aviation Ltd have two large heating units in their main engineering hangar at Farnborough Airport, which would run continuously throughout the day and never reach the thermostat set point of 14°C. Following installation of the Airius system their HVAC system would achieve the thermostat set point with only one of the two heating units running. Once at the temperature set point, the Airius system would then continue to maintain the desired conditions with only the one remaining heating unit running intermittently. In September and October of 2012 (PRE AIRIUS) the heating gas consumption was 2,356m³. In September and October of 2013 (POST AIRIUS) the heating gas consumption was 1,042.3m³.
  • 25. • ROI = Under 18 months • saving • £19,799 – full system and installation cost • 1,141, 113 – kWh usage before Airius • 709,956 – kWh usage after Airius • Installed into acton rail maintenance shed • System – 26 Airius Model 45units • 75 tonnes – Approx. annual CO2 reduction Siemens CASE STUDY Key points: 16:00 08:00 00:00 16:00 08:00 00:00 16:00 08:00 00:00 16:00 08:00 00:00 16:00 08:00 00:00 16:00 08:00 00:00 16:00 08:00 00:00 16:00 08:00 00:00 16:00 08:00 00:00 16:00 08:00 00:00 16:00 08:00 00:00 16:00 08:00 00:00 16:00 08:00 00:00 23o C 22o C 21o C 20o C 19o C 18o C 17o C 16o C 15o C 14o C TEMPERATURE READINGS JAN - FEB ‘12 24|01|1225|01|1226|01|1227|01|1228|01|1229|01|1230|01|1231|01|1201|02|1202|02|1203|02|1204|02|1205|02|12 Ground level Cant Rail levelAirius on Engineering Facility, Acton 2525 Siemens installed 26 Airius model 45 fan units into their Acton rail maintenance shed facility to improve comfort and save on energy costs resulting in an ROI of less than 18 months. The graph below shows the temperature differentials in the Acton rail maintenance shed at both Ground Level and Cant Rail Level with the Airius system off during the week 30/01/12 - 05/02/12, and running during the week 24/01/12 -29/01/12.
  • 26. Get in touch! CONTACT US Airius Europe, Africa, Middle-East & Asia Ashley Heath Industrial Estate Three Legged Cross Dorset BH21 6UZ, UK Tel: (00) 1 202 554200 Fax: (00) 1 202 554396 Email: airflow@airius.co.uk Web: www.airius.co.uk Airius Americas 811 South Sherman Street Longmont, Colorado 80501, USA Tel: (00) 1 888 247 7327 Fax: (00) 1 303 772 8276 Email: info@airiusfans.com Web: www.airiusfans.com Airius Oceania PO Box 6282, Alexandria NSW 2015 Australia Tel: (00) 61 0 401 848 888 Email: info@airius.com.au Web: www.airius.com.au
  • 27. For more case studies, demonstration videos, client lists, testimonials and product information visit us at: www.airius.co.uk
  • 28. USA and foreign Patents granted to AIRIUS LLC, USA, further patents pending. AIRIUS & AIRIUS SYSTEMS is the copyright property of AIRIUS LLC, USA. All material issued by, or emanating from, Airius Europe Ltd is the Copyright property of Airius Europe Ltd , UK. V2.0 saving you energy V2.0 saving you energy USA and foreign Patents granted to AIRIUS LLC, USA, further patents pending. AIRIUS & AIRIUS SYSTEMS is the copyright property of AIRIUS LLC, USA. All material issued by, or emanating from, Airius Europe Ltd is the Copyright property of Airius Europe Ltd , UK.