2. 216.6.2016 2
System levels for separate analysis
Source: ADENE. 2013. Implementing the Energy Performance of the Buildings Directive
(EPBD). Featuring country reports 2012. Electronic version 2013. 368 p.
ISBN 978-972-8646-28-8. http://www.epbd-ca.org/Medias/Pdf/CA3-BOOK-2012-ebook-201310.pdf
3. 316.6.2016 3
Possible boundaries for integrating renewable energy
into NZEB calculations (NZEB = nearly zero-energy building)
Source: ADENE. 2013. Implementing the Energy Performance of the Buildings Directive
(EPBD). Featuring country reports 2012. Electronic version 2013. 368 p.
ISBN 978-972-8646-28-8. http://www.epbd-ca.org/Medias/Pdf/CA3-BOOK-2012-ebook-201310.pdf
4. 416.6.2016 4
Ekologisen kaupunkisuunnittelun periaatteita
Lähde: Nystedt, Å, Sepponen, M. & Virtanen, M. 2012. Ekotaajaman suunnitteluperiaatteet.
VTT Technology 24. 50 s. + liitt. 2 s. http://www.vtt.fi/inf/pdf/technology/2012/T24.pdf
5. 516.6.2016 5
Esimerkki Ruotsista
Lähde: Pandis Iveroth, S., Johansson S. & Brandt, N. 2013. The potential of the infrastructural system of Hammarby Sjöstad
in Stockholm, Sweden. Energy Policy 59 (2013) 716–726. http://dx.doi.org/10.1016/j.enpol.2013.04.027
6. 616.6.2016 6
Energiasuunnittelu osana aluesuunnittelua
Aurinkolämpö
Energiatehokkaat
rakennukset
Tuulienergia
Lämpöpumput
Kaukolämpö
Aurinkosähkö
Energiavarastot
Kaukojäähdytys
Kuva: VTT, www.vtt.fi/inf/pdf/tiedotteet/2010/T2565.pdf
11. 1116.6.2016 11
Heat demand of the building stock with two
scenarios (2012 & SunZED)
0
500
1000
1500
2000
2500
3000
1 2 3 4 5 6 7 8 9 10 11 12
MWh
Lämmöntarve (SunZED)
yht, MWh
Lämmöntarve (2012)
yht, MWh
SunZED: 43,4 kWh/br-m2,a
2012: 62,2 kWh/br-m2,a
12. 1216.6.2016 12
Cooling demand of the building stock with two
scenarios (2012 & SunZED)
0
200
400
600
800
1000
1200
1400
1600
1800
1 2 3 4 5 6 7 8 9 10 11 12
MWh
Kaukojäähdytys
(SunZED), MWh
Kaukojäähdytys (2012),
MWh
SunZED: 23,9 kWh/br-m2,a
2012: 15,9 kWh/br-m2,a
13. 131316.6.2016
Land area requirements
The share of solar collector area
of the total building floor area in
Vartiosaari (m2/m2)
The solar collector area (m2) The required land area of the
tank storage (m2)
0.05 16,250 230
0.1 32,500 460
0.15 48,750 637
0.2 65,000 790
0.25 81,250 814
0.3 – 0.45 97,500 – 146,250 929
> 0.5 162,500 1,057
District case Land area requirement (m2)
SunZED 15,260
2012 reference 21,900
Tank storage
Borehole storage
14. 141416.6.2016
Self-sufficiency in heat production
Ground source heat pump with borehole thermal
energy storage (BTES) and solar collectors Solar assisted district heating with
tank thermal energy storage (TTES)
15. 151516.6.2016
Emissions (CO2, SO2 & particulates): borehole
thermal energy storage (BTES)
All emissions are smaller in
SunZED concept than in
2012 reference
All emissions can be reduced
with BTES (even over 50%)
16. 161616.6.2016
Emissions (CO2, SO2 & particulates): tank
thermal energy storage (TTES)
CO2 and particulates are
smaller in SunZED than in
2012 reference
SO2 is bigger in SunZED
(system consumes more
electricity)
All emissions can be reduced
17. 1716.6.2016 17
Yhteenveto:
Aurinkoenergia osana alueen energiajärjestelmää
Tarkasteltava monelta kannalta
Kokonaisuuden hallinta ja tarkastelu
Aurinkosähkö ja –lämpö osana
laajempaa energiaratkaisua
Energiavarastot tukemassa
Tehokkaampaa isommassa
mittakaavassa
Vartiosaaren energiaselvitys:
www.vtt.fi/inf/pdf/technology/2015/T234.pdf