VMWARE NSX AND
OMNISWITCH 6900
INTEROPERABILITY SETUP
APPLICATION NOTE
VMWARE NSX AND OMNISWITCH 6900 INTEROPERABILITY SETUP
ALCATEL-LUCENT ENTERPRISE APPLICATION NOTE
2
TABLE OF CONTENTS
Overview / 3
	 VMware NSX / 3
	 OmniSwitch 6900 / 3
Topology / 5
Components / 6
Operation / 7
Configuration / 7
	 OmniSwitch 6900 / 7
	 VMware NSX / 9
VMWARE NSX AND OMNISWITCH 6900 INTEROPERABILITY SETUP
ALCATEL-LUCENT ENTERPRISE APPLICATION NOTE
3
OVERVIEW
This document describes how Alcatel-Lucent OmniSwitch® 6900 delivers network
virtualization services and provides configuration steps to show interoperability with
the VMware® NSX™ platform as an L2 hardware virtual extensible local area network
(VXLAN) tunnel end-point (VTEP). Figure 1 illustrates the OmniSwitch 6900 bridging
virtual network traffic to and from the physical external networks.
The integrated solution of these two platforms meets the technical requirements of
today’s enterprises using VMware’s Software-Defined Data Center (SDDC) principles.
This combined solution extends virtualization technologies across the data center and
campus infrastructure.
Figure 1: Physical–to-Virtual gateway example
Non-VXLAN
hypervisor
Physical
External
networks
Virtual
networks
Non-virtualized
server
Physical-to-virtual
VXLANs
L2 VTEP gateway
Management and
controller clusters
VMware NSX
VMware NSX is the network virtualization platform that creates, deletes and restores
software-based virtual networking and the security model from Layer 2 to Layer 7. The
NSX platform operates over existing IP networks.
VMware NSX is the “network hypervisor” for hosts virtualizing workloads over VXLANs.
Not all hypervisors virtualize over VXLAN and not all servers are virtualized. For this
reason it is necessary to allow the bridging and routing of traffic between virtual and
physical networks.
OmniSwitch 6900
The OmniSwitch 6900 family supports hardware VTEP, providing the ability to bridge
or route traffic to and from external networks or non-VXLAN hypervisors into the
VXLAN overlay.
The OmniSwitch 6900 is a key component of our Intelligent Fabric. Intelligent
Fabric is an automated network fabric that creates, deletes and restores VLANs and
network services. It operates in a programmatic and dynamic fashion enabling IP
networking of physical and virtual workloads, which simplifies the tasks of the data
center administrator.
The OmniSwitch 6900 offers programmable Shortest Path Bridging Mac-in-mac
VMWARE NSX AND OMNISWITCH 6900 INTEROPERABILITY SETUP
ALCATEL-LUCENT ENTERPRISE APPLICATION NOTE
4
(SPB-M) and VXLAN services that deliver departmental segmentation, business unit
isolation and transparent subnet extensions over existing enterprise data centers and
campus networks.
Figure 2 illustrates how the OmniSwitch extracts network objects to virtualize tenants
into containers that offer traffic and control isolation. These containers are administered
through the Alcatel-Lucent Operating System (AOS) service manager feature. The AOS
Service manager and the Alcatel-Lucent Enterprise Virtual Network Profiles (vNP)
technology are the AOS features that deliver network virtualization over SPB-M or
VXLAN protocols.
Figure 2: OmniSwitch 6900 network virtualization services
OS6900
AOS Service Manager
VXLAN 1000
VLAN
100
VLAN
200
VLAN
4000
VLAN
100
VLAN
200
VLAN
4094
VXLAN 2000
The OmniSwitch 6900 VXLAN services offer the NSX platform a dynamic infrastructure
that can be consumed and repurposed on demand using vNP and the OmniSwitch 6900
hybrid-mode hardware VTEP.
The underlying physical infrastructure works as an IP transport to physically interconnect
the compute, the management and the controller clusters. The physical infrastructure
enabled by Intelligent Fabric offers error-free zero-touch configuration for a flexible and
simple network deployment.
Once virtual machine (VM) traffic is encapsulated into VXLAN, the physical network
loses visibility to the VM-to-VM communication. To regain visibility and control of the
traffic inside the overlay, the VM snooping function must be enabled. VM snooping is
unique, and brings a detailed view of the contents of VXLANs and allows for control of
the overlay traffic inside the physical network. Vendors without VM snooping capabilities
are “blinded” to VXLAN payload information. Figure 3 illustrates VM snooping.
VMWARE NSX AND OMNISWITCH 6900 INTEROPERABILITY SETUP
ALCATEL-LUCENT ENTERPRISE APPLICATION NOTE
5
Figure 3: VM snooping
VM VMVM VM VMVM
VMwareESXi VMwareESX VMwareESXi
VM VMVM VM VMVM
VMwareESXi VMwareESX VMwareESXi
Cluster
Cluster
Network without VM snooping VM snooping enabled Intelligent Fabric
-> sh vm-snooping database
Total number of VM Flows: 6
Port VNI
VXLAN
PORT
VM
SRC MAC
1/1/1A 4789 2000 E8 : E7 : 32 : FA : 11 : B2 - 192.168.10.1
1/1/1A 4789 2000 E8 : E7 : 32 : FA : 11 : B2 - 192.168.10.2
1/1/1A 4789 2000 E8 : E7 : 32 : FA : 11 : B2 - 192.168.10.3
1/1/1A 4789 2000 E8 : E7 : 32 : FA : 11 : B2 - 192.168.10.150
1/1/1A 4789 2000 E8 : E7 : 32 : FA : 11 : B2 - 192.168.10.140
1/1/1A 4789 2000 E8 : E7 : 32 : FA : 11 : B2 - 192.168.10.140
App 1
App 2
App 3
App 4
App 5
App 6
App 7
App 8
App 15
App 16
App 17
App 14App 11
App 13
vMotion vMotion
vMotion vMotion
VM snooping allows for discovery of VXLANs and its contents. In addition to discovery,
VM snooping also offers dynamic or persistent activation of Access Control List (ACL)/
Quality of Service (QoS) policy list profiles to control VM traffic. The VM traffic can
either be discovered, controlled or both by visual network index (VNI), MAC, VLAN,
IP, transmission control protocol (TCP)/user datagram protocol (UDP) or a combination
of these options. ACL/QoS actions include allow, drop, bandwidth policing, redirection,
mirroring, among others. For more information, refer to OmniSwitch user guides.
Alcatel-Lucent OmniVista® 4.1.2.R02 network management software can be used to
build the underlying infrastructure and rollout the baseline configuration to prepare
the OmniSwitch network for NSX integration. OmniVista then acts as a VMware NSX
integration wizard to configure, for example, bidirectional protocol independent multicast
routing (PIM-BIDIR), and so on, while the NSX controller orchestrates and manages the
VXLANs. OmniVista orchestration is not in the scope of this document.
In this document we will focus on the interoperability of manually configured VXLAN
services with NSX software-based virtual networks.
TOPOLOGY
Figure 4 illustrates the following:
1.	Ability of the OmniSwitch family to provide the Layer 2 and Layer 3 infrastructure
for NSX virtualized networks.
2.	Ability of the OmniSwitch family to interoperate with NSX VTEPs to provide Layer 2
and Layer 3 extensions as hardware VTEP.
This topology represents a virtualized data center (DC) with three compute clusters (A,
B and C) networked using VMware® NSX Virtual Switches™. The NSX Virtual Switches
switch and tunnel data traffic between compute clusters and build the overlay network.
The compute clusters are controlled and managed by the NSX controller cluster.
VMWARE NSX AND OMNISWITCH 6900 INTEROPERABILITY SETUP
ALCATEL-LUCENT ENTERPRISE APPLICATION NOTE
6
Figure 4: Topology
Management
Controllers Compute cluster A Compute cluster B Compute cluster C
OmniSwitch
OS6900-Q32
Hardware
L2 VTEP
Hardware
L3 function
Physical networks
Intelligent Fabric
The NSX controller is the control plane of the NSX infrastructure. It manages the
distributed NSX Virtual Switches. The NSX Virtual Switches provide the network
forwarding functions to the compute clusters and switch and encapsulate VM traffic into
the overlay tunnels. The NSX manager is a web-based graphical user interface used to
interact with the NSX controller for configuration of logical switches, tenant networks
and VM connectivity. The NSX manager can be supplemented in other environments
by cloud orchestrators, such as OpenStack®, to allow workflow provisioning and
bulk configurations.
The Intelligent Fabric provides the physical infrastructure to interconnect VMware
compute, management and controller clusters. Intelligent Fabric extracts the different
components of the network as a single fabric and reduces the complexity of provisioning
the access, aggregation and core layers. Intelligent Fabric offers end-to-end connectivity
from the overlay network to the physical network end device.
The OmniSwitch 6900-Q32 in this topology operates as a Layer 2 gateway to bridge the
logical VXLANs and the physical VLANs in the network. The OmniSwitch 6900-Q32
runs VXLAN as a service to provide hardware-based switching and routing functions for
multi-tenant networks and directly attached devices.
COMPONENTS
•	 3x VMware vSphere® 6.0
•	 1x VMware NSX 6.1.4
•	 1x OmniSwitch OS6900-Q32 running AOS 7.3.4.450.R01
VMWARE NSX AND OMNISWITCH 6900 INTEROPERABILITY SETUP
ALCATEL-LUCENT ENTERPRISE APPLICATION NOTE
7
OPERATION
Once the physical infrastructure is prepared for VMware NSX, the NSX orchestration tool
discovers and displays the OmniSwitch 6900 as a third-party multicast-enabled VTEP.
The OmniSwitch 6900 is registered with NSX to be programmed with the appropriate
VXLANs and their associated ports and VLANs. With this setup, VM mobility, learning
and connectivity work dynamically without further configuration. OmniVista can also be
used to facilitate the preparation of the network.
CONFIGURATION
OmniSwitch 6900
The AOS service manager provides a framework to operate VXLAN or SPB-M
technologies as a service in a distributed, multi-tenant network. With service manager
VLANs, ports and devices are associated with a VXLAN through the configuration of
service objects. This approach defines the VXLAN service domain by configuring the
following service components:
Figure 5: Inside AOS service manager
OS6900
AOS Service Manager
VXLAN 1000
VLAN
100
VLAN
200
VLAN
4000
VLAN
100
VLAN
200
VLAN
4094
VXLAN 2000
SAP 100
SDP
SDP
SDP bind Logical Switch (Is0)
Logical Switch (Is1)
L3 Tunnel
End-point
(IP interface)
L3 Tunnel
(physical L2
Vlan)Service
VXLAN
VNI 1000
Service
VXLAN
VNI 2000
br0 Physical ports
SAP 200
SAP 4000
SAP 4094
SAP 200
SAP 100
Access
port
Access
port
Access
port
“Physical”switch - br0
Uplink
portIPInterface
Vlan
•	 VXLAN service: The OmniSwitch VTEP identifies each VXLAN segment that the
gateway participates in with a VXLAN service ID. A VXLAN service is associated
with a VXLAN Network Identifier (VNI) at the time the service is created. The service
represents a single virtual bridge or logical switch on the VTEP.
•	 Access port: An OmniSwitch port or link aggregate can be configured as a service
access port. The access port is connected to a host or physical network through which
the LAN traffic enters or leaves the VXLAN overlay network. The access port is also
associated with a Layer 2 profile that specifies how to process protocol control frames
received through the port.
•	 Service Access Point (SAP): A SAP is a virtual port that binds an access port VLAN(s)
to a VXLAN service. It is a virtual port in the logical switch. SAPs can be statically
setup through CLI/API or dynamically provisioned through Virtual Network Profiles
(vNP). vNP can provide device authentication and classification before the device is
accepted into a VXLAN service. vNP can be controlled by a user or device policies
administered from a directory manager. Classification rules can include VLANs, MAC
addresses, IP addresses or a combination of these. Authentication is executed through
IEEE 802.1x providing the most secure multi-tenant cloud data center fabric.
VMWARE NSX AND OMNISWITCH 6900 INTEROPERABILITY SETUP
ALCATEL-LUCENT ENTERPRISE APPLICATION NOTE
8
•	 Service Distribution Point (SDP): An SDP is a logical port that serves as the VXLAN
Tunnel Interface (VTI) on a VTEP to extend services to other remote VTEPs. The SDP
multiplexes traffic from all associated VXLANs destined to a remote VTEP. An SDP can
be configured to transport one or many VXLANs.
•	 SDP bind: SDP bind represents the binding of a VXLAN service instance to an SDP.
Here is a code configuration snippet that configures an AOS VXLAN service to connect it
with NSX Virtual Switches based on manually defined configuration:
! SVCMGR:
service vxlan udp-port 8472 « You must change the VXLAN UDP port
from its default value (4789, the IANA standard) to 8472 in order to
interoperate with NSX.
service access port 1/1/3A « This command defines an access port.
service sdp 10 vxlan multicast-group 239.1.1.1 « This command sets
up the tunnel to the remote end points. It accepts unicast or multicast
destinations as remote end points.
service 1000 vxlan vnid 1000 « This command creates the VXLAN
service instance that corresponds to the logical switch associated with a
given VNI.
service 1000 sap port 1/1/3A:100
service 1000 sap port 1/1/3A:200
service 1000 sap port 1/1/3A:4000 « This command creates the
service access port association of the virtual port to the logical switch. :x
represents a VLAN, all VLANs or untagged VLANs existing in the access
port c/s/p.
service 1000 bind-sdp 10 « This command binds the service to a
VXLAN tunnel.
The above configuration assumes that the Intelligent Fabric provides IP connectivity
to all components in the topology shown in Figure 3, including management clusters,
controller clusters, compute clusters as well as the designated OmniSwitch VTEP.
To run ‘operate in multicast replication’ mode, the infrastructure must be running PIM
BI-DIR. This document does not provide information on this topic.
The OmniSwitch VTEP can operate in unicast replication mode, multicast replication
mode or in hybrid mode. Multicast replication is the default operation and allows for
automatic and dynamic discovery of VTEPs. In unicast mode, all remote VTEPs must be
explicitly defined. This is an example of a head-end replication configuration:
service 2000 vxlan vnid 2000 head-end
service sdp 200 vxlan far-end 10.2.2.2
service 2000 bind-sdp 200
VMWARE NSX AND OMNISWITCH 6900 INTEROPERABILITY SETUP
ALCATEL-LUCENT ENTERPRISE APPLICATION NOTE
9
SAPs can be created in dynamic fashion using Virtual Network Profiles. This topic is not
covered in this document.
VMware NSX
The OmniSwitch must be added to the NSX controller as a logical switch. The steps to
include the OmniSwitch in the logical switch list are:
1.	 Create the OmniSwitch VTEP as a logical switch with replication mode set to
multicast (Figure 6).
Enable IP discovery to allow the VTEP to connect to other VTEPs in the same
multicast group.
Enable MAC learning to use learning functionality in the switch.
Figure 6: Add OmniSwitch as logical switch
2.	 Define the multicast group to which the OmniSwitch VTEP should connect to
discover other VTEPs.
Configure the VNI range to define the VXLANs available for that VTEP in the
specified multicast group. (Figure 7 as a simple test.)
enterprise.alcatel-lucent.com Alcatel-Lucent and the Alcatel-Lucent Enterprise logo are trademarks of Alcatel-Lucent. To view
other trademarks used by affiliated companies of ALE Holding, visit: enterprise.alcatel-lucent.com/trademarks. All other trademarks
are the property of their respective owners. The information presented is subject to change without notice. Neither ALE Holding nor
any of its affiliates assumes any responsibility for inaccuracies contained herein. (September 2015)
Figure 7: Define VNI range and Multicast group to which the VTEP connects
3.	 When the configuration is completed and the VTEP is in contact, the OmniSwitch
VTEP should be listed as Normal in the Status column. (Figure 8)
Figure 8: Logical switches list
Disclaimer
This document was created using the official VMware icon and diagram library. Copyright© 2012 VMware, Inc. All rights
reserved. This product is protected by U.S. and international copyright and intellectual property laws. VMware products are
covered by one or more patents listed at http://www.vmware.com/go/patents.
VMware does not endorse or make any representations about third party information included in this document, nor does the
inclusion of any VMware icon or diagram in this document imply such an endorsement.

More Related Content

Viewers also liked

Samuel padilla renteria
Samuel padilla renteriaSamuel padilla renteria
Samuel padilla renteria
Samuel Padilla
 
2011 sanchez et al bj and nitrogen fixation
2011 sanchez et al bj and nitrogen fixation2011 sanchez et al bj and nitrogen fixation
2011 sanchez et al bj and nitrogen fixation
Germán Tortosa
 
1340461550 72d6729a10905a0ac4aac4bfc2c0100e
1340461550 72d6729a10905a0ac4aac4bfc2c0100e1340461550 72d6729a10905a0ac4aac4bfc2c0100e
1340461550 72d6729a10905a0ac4aac4bfc2c0100e
ivan0821
 
Xv ftf el_internet_de_las_cosas
Xv ftf el_internet_de_las_cosasXv ftf el_internet_de_las_cosas
Xv ftf el_internet_de_las_cosas
Sodepal
 
Tejas plásticas sunrise con sistema antigoteras (1)
Tejas plásticas sunrise con sistema antigoteras (1)Tejas plásticas sunrise con sistema antigoteras (1)
Tejas plásticas sunrise con sistema antigoteras (1)
Apoyo A Pymes
 

Viewers also liked (15)

Cancer cervicouterino
Cancer cervicouterinoCancer cervicouterino
Cancer cervicouterino
 
Bacalah!
Bacalah!Bacalah!
Bacalah!
 
Samuel padilla renteria
Samuel padilla renteriaSamuel padilla renteria
Samuel padilla renteria
 
2011 sanchez et al bj and nitrogen fixation
2011 sanchez et al bj and nitrogen fixation2011 sanchez et al bj and nitrogen fixation
2011 sanchez et al bj and nitrogen fixation
 
Conactor estate agent -makler german
Conactor   estate agent -makler  germanConactor   estate agent -makler  german
Conactor estate agent -makler german
 
1340461550 72d6729a10905a0ac4aac4bfc2c0100e
1340461550 72d6729a10905a0ac4aac4bfc2c0100e1340461550 72d6729a10905a0ac4aac4bfc2c0100e
1340461550 72d6729a10905a0ac4aac4bfc2c0100e
 
Encuentro Toledo_Plataforma Voluntariado Albacete
Encuentro Toledo_Plataforma Voluntariado AlbaceteEncuentro Toledo_Plataforma Voluntariado Albacete
Encuentro Toledo_Plataforma Voluntariado Albacete
 
Vtesse Cirrus Brochure
Vtesse Cirrus BrochureVtesse Cirrus Brochure
Vtesse Cirrus Brochure
 
Xv ftf el_internet_de_las_cosas
Xv ftf el_internet_de_las_cosasXv ftf el_internet_de_las_cosas
Xv ftf el_internet_de_las_cosas
 
Company Data by SmartPhone mobile.infobroker.de 1.2
Company Data by SmartPhone mobile.infobroker.de 1.2Company Data by SmartPhone mobile.infobroker.de 1.2
Company Data by SmartPhone mobile.infobroker.de 1.2
 
Masificacion del gas natural
Masificacion del gas naturalMasificacion del gas natural
Masificacion del gas natural
 
Tejas plásticas sunrise con sistema antigoteras (1)
Tejas plásticas sunrise con sistema antigoteras (1)Tejas plásticas sunrise con sistema antigoteras (1)
Tejas plásticas sunrise con sistema antigoteras (1)
 
ENERTRAG Präsentation 2012
ENERTRAG Präsentation 2012ENERTRAG Präsentation 2012
ENERTRAG Präsentation 2012
 
My Brain Hurts by Y&R
My Brain Hurts by Y&RMy Brain Hurts by Y&R
My Brain Hurts by Y&R
 
MainBoard o Tarjeta Madre
MainBoard o Tarjeta MadreMainBoard o Tarjeta Madre
MainBoard o Tarjeta Madre
 

More from Benjamin Eggerstedt

Delivering Application Analytics for an Application Fluent Network
Delivering Application Analytics for an Application Fluent NetworkDelivering Application Analytics for an Application Fluent Network
Delivering Application Analytics for an Application Fluent Network
Benjamin Eggerstedt
 

More from Benjamin Eggerstedt (7)

Alcatel-Lucent Enterprise Produktportfolio H2-2016
Alcatel-Lucent Enterprise Produktportfolio H2-2016Alcatel-Lucent Enterprise Produktportfolio H2-2016
Alcatel-Lucent Enterprise Produktportfolio H2-2016
 
Delivering Application Analytics for an Application Fluent Network
Delivering Application Analytics for an Application Fluent NetworkDelivering Application Analytics for an Application Fluent Network
Delivering Application Analytics for an Application Fluent Network
 
802.11ac Gigabit Wi-Fi Infographic
802.11ac Gigabit Wi-Fi Infographic802.11ac Gigabit Wi-Fi Infographic
802.11ac Gigabit Wi-Fi Infographic
 
Openstack Neutron plug-in for Alcatel-Lucent Enterprise OmniSwitch
Openstack Neutron plug-in for Alcatel-Lucent Enterprise OmniSwitchOpenstack Neutron plug-in for Alcatel-Lucent Enterprise OmniSwitch
Openstack Neutron plug-in for Alcatel-Lucent Enterprise OmniSwitch
 
SDN Enablement for Microsoft Hyper-V powered Data Centers
SDN Enablement for Microsoft Hyper-V powered Data CentersSDN Enablement for Microsoft Hyper-V powered Data Centers
SDN Enablement for Microsoft Hyper-V powered Data Centers
 
Alcatel-Lucent OmniSwitch 6860/E AOS 8.1.1 Access Guardian and BYOD configura...
Alcatel-Lucent OmniSwitch 6860/E AOS 8.1.1 Access Guardian and BYOD configura...Alcatel-Lucent OmniSwitch 6860/E AOS 8.1.1 Access Guardian and BYOD configura...
Alcatel-Lucent OmniSwitch 6860/E AOS 8.1.1 Access Guardian and BYOD configura...
 
Alcatel-Lucent Webinar Pod & Mesh für Data Center mit OmniSwitch
Alcatel-Lucent Webinar Pod & Mesh für Data Center mit OmniSwitchAlcatel-Lucent Webinar Pod & Mesh für Data Center mit OmniSwitch
Alcatel-Lucent Webinar Pod & Mesh für Data Center mit OmniSwitch
 

Recently uploaded

Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and Myths
Joaquim Jorge
 
Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slide
vu2urc
 

Recently uploaded (20)

Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...
 
Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and Myths
 
🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
 
Tech Trends Report 2024 Future Today Institute.pdf
Tech Trends Report 2024 Future Today Institute.pdfTech Trends Report 2024 Future Today Institute.pdf
Tech Trends Report 2024 Future Today Institute.pdf
 
Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected Worker
 
Advantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your BusinessAdvantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your Business
 
Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)
 
GenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationGenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day Presentation
 
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law DevelopmentsTrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processors
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected Worker
 
Boost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfBoost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdf
 
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data DiscoveryTrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
 
Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slide
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed texts
 
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
 

VMware NSX and Alcatel-Lucent Enterprise OmniSwitch 6900 Application Note

  • 1. VMWARE NSX AND OMNISWITCH 6900 INTEROPERABILITY SETUP APPLICATION NOTE
  • 2. VMWARE NSX AND OMNISWITCH 6900 INTEROPERABILITY SETUP ALCATEL-LUCENT ENTERPRISE APPLICATION NOTE 2 TABLE OF CONTENTS Overview / 3 VMware NSX / 3 OmniSwitch 6900 / 3 Topology / 5 Components / 6 Operation / 7 Configuration / 7 OmniSwitch 6900 / 7 VMware NSX / 9
  • 3. VMWARE NSX AND OMNISWITCH 6900 INTEROPERABILITY SETUP ALCATEL-LUCENT ENTERPRISE APPLICATION NOTE 3 OVERVIEW This document describes how Alcatel-Lucent OmniSwitch® 6900 delivers network virtualization services and provides configuration steps to show interoperability with the VMware® NSX™ platform as an L2 hardware virtual extensible local area network (VXLAN) tunnel end-point (VTEP). Figure 1 illustrates the OmniSwitch 6900 bridging virtual network traffic to and from the physical external networks. The integrated solution of these two platforms meets the technical requirements of today’s enterprises using VMware’s Software-Defined Data Center (SDDC) principles. This combined solution extends virtualization technologies across the data center and campus infrastructure. Figure 1: Physical–to-Virtual gateway example Non-VXLAN hypervisor Physical External networks Virtual networks Non-virtualized server Physical-to-virtual VXLANs L2 VTEP gateway Management and controller clusters VMware NSX VMware NSX is the network virtualization platform that creates, deletes and restores software-based virtual networking and the security model from Layer 2 to Layer 7. The NSX platform operates over existing IP networks. VMware NSX is the “network hypervisor” for hosts virtualizing workloads over VXLANs. Not all hypervisors virtualize over VXLAN and not all servers are virtualized. For this reason it is necessary to allow the bridging and routing of traffic between virtual and physical networks. OmniSwitch 6900 The OmniSwitch 6900 family supports hardware VTEP, providing the ability to bridge or route traffic to and from external networks or non-VXLAN hypervisors into the VXLAN overlay. The OmniSwitch 6900 is a key component of our Intelligent Fabric. Intelligent Fabric is an automated network fabric that creates, deletes and restores VLANs and network services. It operates in a programmatic and dynamic fashion enabling IP networking of physical and virtual workloads, which simplifies the tasks of the data center administrator. The OmniSwitch 6900 offers programmable Shortest Path Bridging Mac-in-mac
  • 4. VMWARE NSX AND OMNISWITCH 6900 INTEROPERABILITY SETUP ALCATEL-LUCENT ENTERPRISE APPLICATION NOTE 4 (SPB-M) and VXLAN services that deliver departmental segmentation, business unit isolation and transparent subnet extensions over existing enterprise data centers and campus networks. Figure 2 illustrates how the OmniSwitch extracts network objects to virtualize tenants into containers that offer traffic and control isolation. These containers are administered through the Alcatel-Lucent Operating System (AOS) service manager feature. The AOS Service manager and the Alcatel-Lucent Enterprise Virtual Network Profiles (vNP) technology are the AOS features that deliver network virtualization over SPB-M or VXLAN protocols. Figure 2: OmniSwitch 6900 network virtualization services OS6900 AOS Service Manager VXLAN 1000 VLAN 100 VLAN 200 VLAN 4000 VLAN 100 VLAN 200 VLAN 4094 VXLAN 2000 The OmniSwitch 6900 VXLAN services offer the NSX platform a dynamic infrastructure that can be consumed and repurposed on demand using vNP and the OmniSwitch 6900 hybrid-mode hardware VTEP. The underlying physical infrastructure works as an IP transport to physically interconnect the compute, the management and the controller clusters. The physical infrastructure enabled by Intelligent Fabric offers error-free zero-touch configuration for a flexible and simple network deployment. Once virtual machine (VM) traffic is encapsulated into VXLAN, the physical network loses visibility to the VM-to-VM communication. To regain visibility and control of the traffic inside the overlay, the VM snooping function must be enabled. VM snooping is unique, and brings a detailed view of the contents of VXLANs and allows for control of the overlay traffic inside the physical network. Vendors without VM snooping capabilities are “blinded” to VXLAN payload information. Figure 3 illustrates VM snooping.
  • 5. VMWARE NSX AND OMNISWITCH 6900 INTEROPERABILITY SETUP ALCATEL-LUCENT ENTERPRISE APPLICATION NOTE 5 Figure 3: VM snooping VM VMVM VM VMVM VMwareESXi VMwareESX VMwareESXi VM VMVM VM VMVM VMwareESXi VMwareESX VMwareESXi Cluster Cluster Network without VM snooping VM snooping enabled Intelligent Fabric -> sh vm-snooping database Total number of VM Flows: 6 Port VNI VXLAN PORT VM SRC MAC 1/1/1A 4789 2000 E8 : E7 : 32 : FA : 11 : B2 - 192.168.10.1 1/1/1A 4789 2000 E8 : E7 : 32 : FA : 11 : B2 - 192.168.10.2 1/1/1A 4789 2000 E8 : E7 : 32 : FA : 11 : B2 - 192.168.10.3 1/1/1A 4789 2000 E8 : E7 : 32 : FA : 11 : B2 - 192.168.10.150 1/1/1A 4789 2000 E8 : E7 : 32 : FA : 11 : B2 - 192.168.10.140 1/1/1A 4789 2000 E8 : E7 : 32 : FA : 11 : B2 - 192.168.10.140 App 1 App 2 App 3 App 4 App 5 App 6 App 7 App 8 App 15 App 16 App 17 App 14App 11 App 13 vMotion vMotion vMotion vMotion VM snooping allows for discovery of VXLANs and its contents. In addition to discovery, VM snooping also offers dynamic or persistent activation of Access Control List (ACL)/ Quality of Service (QoS) policy list profiles to control VM traffic. The VM traffic can either be discovered, controlled or both by visual network index (VNI), MAC, VLAN, IP, transmission control protocol (TCP)/user datagram protocol (UDP) or a combination of these options. ACL/QoS actions include allow, drop, bandwidth policing, redirection, mirroring, among others. For more information, refer to OmniSwitch user guides. Alcatel-Lucent OmniVista® 4.1.2.R02 network management software can be used to build the underlying infrastructure and rollout the baseline configuration to prepare the OmniSwitch network for NSX integration. OmniVista then acts as a VMware NSX integration wizard to configure, for example, bidirectional protocol independent multicast routing (PIM-BIDIR), and so on, while the NSX controller orchestrates and manages the VXLANs. OmniVista orchestration is not in the scope of this document. In this document we will focus on the interoperability of manually configured VXLAN services with NSX software-based virtual networks. TOPOLOGY Figure 4 illustrates the following: 1. Ability of the OmniSwitch family to provide the Layer 2 and Layer 3 infrastructure for NSX virtualized networks. 2. Ability of the OmniSwitch family to interoperate with NSX VTEPs to provide Layer 2 and Layer 3 extensions as hardware VTEP. This topology represents a virtualized data center (DC) with three compute clusters (A, B and C) networked using VMware® NSX Virtual Switches™. The NSX Virtual Switches switch and tunnel data traffic between compute clusters and build the overlay network. The compute clusters are controlled and managed by the NSX controller cluster.
  • 6. VMWARE NSX AND OMNISWITCH 6900 INTEROPERABILITY SETUP ALCATEL-LUCENT ENTERPRISE APPLICATION NOTE 6 Figure 4: Topology Management Controllers Compute cluster A Compute cluster B Compute cluster C OmniSwitch OS6900-Q32 Hardware L2 VTEP Hardware L3 function Physical networks Intelligent Fabric The NSX controller is the control plane of the NSX infrastructure. It manages the distributed NSX Virtual Switches. The NSX Virtual Switches provide the network forwarding functions to the compute clusters and switch and encapsulate VM traffic into the overlay tunnels. The NSX manager is a web-based graphical user interface used to interact with the NSX controller for configuration of logical switches, tenant networks and VM connectivity. The NSX manager can be supplemented in other environments by cloud orchestrators, such as OpenStack®, to allow workflow provisioning and bulk configurations. The Intelligent Fabric provides the physical infrastructure to interconnect VMware compute, management and controller clusters. Intelligent Fabric extracts the different components of the network as a single fabric and reduces the complexity of provisioning the access, aggregation and core layers. Intelligent Fabric offers end-to-end connectivity from the overlay network to the physical network end device. The OmniSwitch 6900-Q32 in this topology operates as a Layer 2 gateway to bridge the logical VXLANs and the physical VLANs in the network. The OmniSwitch 6900-Q32 runs VXLAN as a service to provide hardware-based switching and routing functions for multi-tenant networks and directly attached devices. COMPONENTS • 3x VMware vSphere® 6.0 • 1x VMware NSX 6.1.4 • 1x OmniSwitch OS6900-Q32 running AOS 7.3.4.450.R01
  • 7. VMWARE NSX AND OMNISWITCH 6900 INTEROPERABILITY SETUP ALCATEL-LUCENT ENTERPRISE APPLICATION NOTE 7 OPERATION Once the physical infrastructure is prepared for VMware NSX, the NSX orchestration tool discovers and displays the OmniSwitch 6900 as a third-party multicast-enabled VTEP. The OmniSwitch 6900 is registered with NSX to be programmed with the appropriate VXLANs and their associated ports and VLANs. With this setup, VM mobility, learning and connectivity work dynamically without further configuration. OmniVista can also be used to facilitate the preparation of the network. CONFIGURATION OmniSwitch 6900 The AOS service manager provides a framework to operate VXLAN or SPB-M technologies as a service in a distributed, multi-tenant network. With service manager VLANs, ports and devices are associated with a VXLAN through the configuration of service objects. This approach defines the VXLAN service domain by configuring the following service components: Figure 5: Inside AOS service manager OS6900 AOS Service Manager VXLAN 1000 VLAN 100 VLAN 200 VLAN 4000 VLAN 100 VLAN 200 VLAN 4094 VXLAN 2000 SAP 100 SDP SDP SDP bind Logical Switch (Is0) Logical Switch (Is1) L3 Tunnel End-point (IP interface) L3 Tunnel (physical L2 Vlan)Service VXLAN VNI 1000 Service VXLAN VNI 2000 br0 Physical ports SAP 200 SAP 4000 SAP 4094 SAP 200 SAP 100 Access port Access port Access port “Physical”switch - br0 Uplink portIPInterface Vlan • VXLAN service: The OmniSwitch VTEP identifies each VXLAN segment that the gateway participates in with a VXLAN service ID. A VXLAN service is associated with a VXLAN Network Identifier (VNI) at the time the service is created. The service represents a single virtual bridge or logical switch on the VTEP. • Access port: An OmniSwitch port or link aggregate can be configured as a service access port. The access port is connected to a host or physical network through which the LAN traffic enters or leaves the VXLAN overlay network. The access port is also associated with a Layer 2 profile that specifies how to process protocol control frames received through the port. • Service Access Point (SAP): A SAP is a virtual port that binds an access port VLAN(s) to a VXLAN service. It is a virtual port in the logical switch. SAPs can be statically setup through CLI/API or dynamically provisioned through Virtual Network Profiles (vNP). vNP can provide device authentication and classification before the device is accepted into a VXLAN service. vNP can be controlled by a user or device policies administered from a directory manager. Classification rules can include VLANs, MAC addresses, IP addresses or a combination of these. Authentication is executed through IEEE 802.1x providing the most secure multi-tenant cloud data center fabric.
  • 8. VMWARE NSX AND OMNISWITCH 6900 INTEROPERABILITY SETUP ALCATEL-LUCENT ENTERPRISE APPLICATION NOTE 8 • Service Distribution Point (SDP): An SDP is a logical port that serves as the VXLAN Tunnel Interface (VTI) on a VTEP to extend services to other remote VTEPs. The SDP multiplexes traffic from all associated VXLANs destined to a remote VTEP. An SDP can be configured to transport one or many VXLANs. • SDP bind: SDP bind represents the binding of a VXLAN service instance to an SDP. Here is a code configuration snippet that configures an AOS VXLAN service to connect it with NSX Virtual Switches based on manually defined configuration: ! SVCMGR: service vxlan udp-port 8472 « You must change the VXLAN UDP port from its default value (4789, the IANA standard) to 8472 in order to interoperate with NSX. service access port 1/1/3A « This command defines an access port. service sdp 10 vxlan multicast-group 239.1.1.1 « This command sets up the tunnel to the remote end points. It accepts unicast or multicast destinations as remote end points. service 1000 vxlan vnid 1000 « This command creates the VXLAN service instance that corresponds to the logical switch associated with a given VNI. service 1000 sap port 1/1/3A:100 service 1000 sap port 1/1/3A:200 service 1000 sap port 1/1/3A:4000 « This command creates the service access port association of the virtual port to the logical switch. :x represents a VLAN, all VLANs or untagged VLANs existing in the access port c/s/p. service 1000 bind-sdp 10 « This command binds the service to a VXLAN tunnel. The above configuration assumes that the Intelligent Fabric provides IP connectivity to all components in the topology shown in Figure 3, including management clusters, controller clusters, compute clusters as well as the designated OmniSwitch VTEP. To run ‘operate in multicast replication’ mode, the infrastructure must be running PIM BI-DIR. This document does not provide information on this topic. The OmniSwitch VTEP can operate in unicast replication mode, multicast replication mode or in hybrid mode. Multicast replication is the default operation and allows for automatic and dynamic discovery of VTEPs. In unicast mode, all remote VTEPs must be explicitly defined. This is an example of a head-end replication configuration: service 2000 vxlan vnid 2000 head-end service sdp 200 vxlan far-end 10.2.2.2 service 2000 bind-sdp 200
  • 9. VMWARE NSX AND OMNISWITCH 6900 INTEROPERABILITY SETUP ALCATEL-LUCENT ENTERPRISE APPLICATION NOTE 9 SAPs can be created in dynamic fashion using Virtual Network Profiles. This topic is not covered in this document. VMware NSX The OmniSwitch must be added to the NSX controller as a logical switch. The steps to include the OmniSwitch in the logical switch list are: 1. Create the OmniSwitch VTEP as a logical switch with replication mode set to multicast (Figure 6). Enable IP discovery to allow the VTEP to connect to other VTEPs in the same multicast group. Enable MAC learning to use learning functionality in the switch. Figure 6: Add OmniSwitch as logical switch 2. Define the multicast group to which the OmniSwitch VTEP should connect to discover other VTEPs. Configure the VNI range to define the VXLANs available for that VTEP in the specified multicast group. (Figure 7 as a simple test.)
  • 10. enterprise.alcatel-lucent.com Alcatel-Lucent and the Alcatel-Lucent Enterprise logo are trademarks of Alcatel-Lucent. To view other trademarks used by affiliated companies of ALE Holding, visit: enterprise.alcatel-lucent.com/trademarks. All other trademarks are the property of their respective owners. The information presented is subject to change without notice. Neither ALE Holding nor any of its affiliates assumes any responsibility for inaccuracies contained herein. (September 2015) Figure 7: Define VNI range and Multicast group to which the VTEP connects 3. When the configuration is completed and the VTEP is in contact, the OmniSwitch VTEP should be listed as Normal in the Status column. (Figure 8) Figure 8: Logical switches list Disclaimer This document was created using the official VMware icon and diagram library. Copyright© 2012 VMware, Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. VMware products are covered by one or more patents listed at http://www.vmware.com/go/patents. VMware does not endorse or make any representations about third party information included in this document, nor does the inclusion of any VMware icon or diagram in this document imply such an endorsement.