1. State-of-the-art R&D and Manufacturing facility Service centres across India
Features & Benefits
XX Double Conversion Online UPS
XX Intelligent Microprocessor Control
XX Wide Input Range
XX True Galvanic Isolation
XX Heavy Duty Charger
XX Cold Start on Battery
XX High Efficiency
XX Compact Size
XX True Sine Wave Output
XX SNMP compactable
XX Suitable for Inductive Load
Megaline ML11T series
(1 KVA to 10 KVA)
Online UPS
Online UPS Range
ML 11 Series 1 - 10 KVA
ML 11T Series 1 - 10 KVA
ML 31 Series 10 - 20 KVA
ML 31T Series 10 - 50 KVA
ML 33 Series 10 - 500 KVA
ML 33T Series 10 - 250 KVA
2. 4/329A, Old Mahabalipuram Road, Chennai – 600 041
Telephone: +91 44 3000 4100 / 10 / 20
E-mail: enquiry@consulindia.com
Website: www.consulindia.com
Consul Consolidated Pvt. Ltd.
Voltage Stabilizers Solar PCUSolar Power PacksIndustrial Inverters TransformersOnline UPS Custom Solutions
Technical Specifications – ML 11T Series
Capacity 1 KVA 2 KVA / 3 KVA 5 KVA 6 KVA 7.5 KVA 10 KVA
Input
Voltage Range 230 V + 20% - 30%
Frequency 50 Hz ± 10%
Input Power Factor* >0.98
Charging Time 8 - 10 Hours for 90% of full capacity
Phase Single Phase
DC Voltage 48 / 72 V 72 / 144 V 144 V 180 V
Inverter / Output
Technology IGBT / MOSFET Double Conversion
Output Voltage 230V AC Single Phase
Voltage Regulation ± 1% for DC I/P variation & O/P load variation
Frequency 50 Hz ± 0.5 Hz (free running mode)
Wave Form PWM Sine Wave
Harmonic Distortion Less than 3% (no load to full load)
Inverter Efficiency > 85 % for 48/72V , >90 % for 144/180V
Power Factor 0.8
Overload a) 105% continuously, b) 105% to 120% 5 mins, c) 150 % for 15 secs
Crest Factor 3:1
Transient Response ± 4% under full load change and corrected within 60 msec
Audible Noise Less than 45 dB at 1 Meter
Metering (Optional)
Microprocessor Based
Digital LCD Meter for
Output Voltage, Output Current & Frequency, DC Voltage & Current, Battery and Load Percentage
Protections
Output Overload & Short Circuit, Output Under & Overvoltage, DC Under & Overvoltage
Indications & Alarms
a) Mains On Indication
b) Inverter On Indication
c) DC Low Indication & Alarm
d) Fault Indication & Alarm
e) Output Overload Indication & Alarm
f) Mains Fail Indication & Alarm
Bypass Facility
Manual Bypass Available in 5 KVA
Static Bypass Optional for all Models
Computer Interface (Optional)
Interface Type Standard DB9 Connector (Dry Contact Type)
Software Compatibility For Windows 95/98, Windows NT, Windows 2000
General
Humidity Max 95%, Non-condensing
Operating Temperature 0°C to 50°C
Dimensions (L x W x H) in mm 650 x 250 x 500 700 x 280 x 750
* Optional Feature
„ Specifications are subject to change without prior notice due to constant improvement in design & technology „ Custom models available on request