Diese Präsentation wurde erfolgreich gemeldet.
Wir verwenden Ihre LinkedIn Profilangaben und Informationen zu Ihren Aktivitäten, um Anzeigen zu personalisieren und Ihnen relevantere Inhalte anzuzeigen. Sie können Ihre Anzeigeneinstellungen jederzeit ändern.
Vedard Security Alarm Technology
https://www.vedard.com https://www.vedardalarm.com sales@vedard.com
Addressable fire alar...
Addressable
Input&Output Module
FW19110
Loop Voltage Rangege: 15 to 28VDC Volts
Non-polarized
External power supply: 15 to...
Nächste SlideShare
Wird geladen in …5
×
Nächste SlideShare
What to Upload to SlideShare
Weiter
Herunterladen, um offline zu lesen und im Vollbildmodus anzuzeigen.

0

Teilen

Herunterladen, um offline zu lesen

Addressable fire system pricelist(fw) vedard

Herunterladen, um offline zu lesen

Complete addressable fire alarm and fire components for designing fire security project. Easy fire security solution with all fire security materials alarm panel, smoke alarm, siren strobe, manual call point, heat detector.

Ähnliche Bücher

Kostenlos mit einer 30-tägigen Testversion von Scribd

Alle anzeigen

Ähnliche Hörbücher

Kostenlos mit einer 30-tägigen Testversion von Scribd

Alle anzeigen
  • Gehören Sie zu den Ersten, denen das gefällt!

Addressable fire system pricelist(fw) vedard

  1. 1. Vedard Security Alarm Technology https://www.vedard.com https://www.vedardalarm.com sales@vedard.com Addressable fire alarm system price Picture Name Model specification Unit Price Addressable Smoke Detector with base JTY-GM- FW19010 Operating voltage: 15 to 28VDC Volts Non-polarized Operating current: Standby Current ≤0 .5mA@28VDC Alarm current: ≤≤2 .8mA@28VDC Smoke sensitivity:0.12 to 0. 25dB/m Size:101.5*46mm piece $8.00 Addressable Heat Detector with base JTW-ZDM- FW19020 Operating voltage: 15 to 28VDC Volts Non-polarized Operating current: Standby current: ≤0 .5mA@28VDC Alarm current: ≤ 3mA@28VDC Temperature Class: A2R Size: 101.5*46mm piece $8.00 Addressable Manual Call Point/Button J-SAP-M- FW19030 Operating voltage 15 to 28VDC Volts Non-polarized Operating current Standby current: ≤0 .5mA@28VDC Alarm current: ≤2 .3mA@28VDC Alarm: Push the button manual Alarm Resettable: Specific key Size:90mm*90mm*33mm piece $9.00 Addressable Sound and Light Siren FW19950B Operating Voltage: 15 to 28VDC Volts Non- polarized External power supply: 20 to 28VDC Volts standby current ≤5mA@24VDC Alarm Current: ≤5mA@24VDC Maximum External Power Alarm Current:≤ 50mA@24VDC Sound level: 75dB~115dB Strobe signal strength: >75cd Size:145mm*115mm*60mm piece $10.00 input module FW19050 Working voltage: linkage 15-28V Impulse voltage Working current:Standby current:≤ 0.55mA action current:≤5.5mA Type:Addressable, 2 wire(nonpolarity) Encoding: Electronic code Dimensions :56mm×56mm×21.5mm (transparent cover not included) Weight: about 53g(transparent cover included) piece $8.00 Short Isolator Module FW19090 Operating Voltage Range: 15 to 28VDC Volts Non-polarized Standby Current: ≤50.uA@28VDC Maximum Alarm Current(LED on): ≤2 .0mA@28VDC Load Capacity 1: Loop 24V@100mA Load Capacity 2(Short “K“Terminal): Loop 24V@200mA Size: 56mm*56mm*21.5mm piece $8.00
  2. 2. Addressable Input&Output Module FW19110 Loop Voltage Rangege: 15 to 28VDC Volts Non-polarized External power supply: 15 to 28VDC Volts Standby Current: ≤ 0..65mA@28VDC Maximum Alarm Current(LED on): ≤ 2mA@28VDC Relay contacts capacity: 2Amp@24VDC Power output capability: 2Amp@24VDC Size: 65mm*65mm*23mm piece $9.00 Addressable Fire Repeater Panel FW19080 LCD displays in English. Sound and light alarm can be signaled together with alarm controller. Four function keys of Mute, Check Up, Check Down and Search. Using loop bus for connecting. piece $65.00 Addressable Programmer FW19062 write address for detector and module,etc. piece $65.00 1 Loop Addressable Fire Alarm Control Panel FW6000 1 Loop : 200 points optional Primary AC: 220VAC 50/60 Hz Main supply output voltage(VDC): 27VDC&32VDC Main supply output current: 2.5A &27VDC and 0.3A &32VDC Minimum Battery Size 2 x 12VRequired: 4Ah Battery charging voltage(VDC): 27VDC Battery charging current: 700mA Size: 330mm*120mm*400mm Net Weight: 7.8KG Set $430.00(200P) 1 and 2 Loops Addressable Fire Alarm Control Panel FW9000 1 Loop : 242points 2 Loop: 484 Points Primary AC: 220VAC 50/60 Hz Main supply output voltage(VDC): 27VDC&32VDC Main supply output current: 2.5A &27VDC and 0.3A &32VDC Minimum Battery Size 2 x 12VRequired: DC12V /7Ah Battery charging voltage(VDC): 27VDC Battery charging current: 700mA Size: 470mm*130mm*420mm Net Weight: 16.8KG Set $510.00(242P) $630.00(484P)

Complete addressable fire alarm and fire components for designing fire security project. Easy fire security solution with all fire security materials alarm panel, smoke alarm, siren strobe, manual call point, heat detector.

Aufrufe

Aufrufe insgesamt

7

Auf Slideshare

0

Aus Einbettungen

0

Anzahl der Einbettungen

0

Befehle

Downloads

0

Geteilt

0

Kommentare

0

Likes

0

×