Vasthi Instruments is the manufacturer and supplier of state-of-the-art ambient ozone gas analyzers throughout India. The monitors use the ultraviolet spectrophotometry principle to accurately measure ozone levels.
1. Air Quality Monitoring System
Innovation Leader of Green Technology
Ozone
Analyzer
410
Ranges 0-0.1 / 0.5 / 1 ppm, user selectable.
7inch TFT LCD & touch screen interface.
Ethernet, RS-232, RS-485 & USB ports.
USB interface utilizes for System Program Update.
Temperature & pressure compensation
Internal zero(optional)
Stored data can be retrieved RS-232, USB Interface
and TCP/IP network
In built Data Logger Utilizes NAND-Flash to Store up
to 5min/1year averaged data
C 5bU`mnYf :YUhifYg
.&;640ⳁ
OBMZ[FSJTUIFBOBMZ[FSUIBUNFBTVSFTNJOJNVN
BNPVOUPG0ⳁ
JOBJSDPSSFDUMZVTJOHUIF67BCTPSQUJPONFUIPE
5IFBOBMZ[FSJTFRVJQQFEXJUIIJHIQFSGPSNBODFBOEIJHIFGGJDJFODZ
0ⳁ
4DSVCCFSBOEVTFEUIFTQFDJNFOUVCFPGTQFDJBMDPBUJOHBOE
NBUFSJBMTUPSFNPWFUIFPCTUBDMFDPNQPOFOUTBOEQSFWFOUUIF
BEIFTJPOPGTQFDJNFOGPSUIFNFBTVSFNFOUPGNJOJNVNBNPVOU
PGP[POF
MMHBTBOBMZ[FSTPG.;64TFSJFTXFSFFRVJQQFEXJUITDSFFO
JOUFSGBDFEFTJHOVTJOH5'5-$%5PVDITDSFFOTPUIBUVTFSDBO
PQFSBUFUIFBOBMZ[FSBOENBYJNJ[FUIFWJTVBMJNBHF BOE.$6
BQQMJFEUPUIFBOBMZ[FSJT3.CJUQSPDFTTPSBOEPQFSBUFT
CBTFEPO-JOVY,FSOFMXIJDINBYJNJ[FTUIFTZTUFNTUBCJMJUZ
EVFUPNVUJQSPDFTTJOH
*OBEEJUJPO UIFBOBMZ[FSJTFRVJQQFEXJUIBVUPNBUJD[FSPDPSSFDUJPO
TZTUFN VUP;FSP GPSTNPPUINFBTVSFNFOUBOEWBSJPVTJOUFSGBDFT
UIFSOFU 34 34 64# %*0 OBMPHPVU TPUIBUVTFSDBO
VTFJUNPSFDPOWFOJFOUMZBOEVTFGVMMZ
1year(5min averaged data)
US EPA Reference Method: EQOA-0219-251
2. Air Quality Monitoring System
Innovation Leader of Green Technology www.kentek.co.kr
3N)BOTJO4.$ 5FDIOPSP :VTFPVOHHV
%BFKFPO,PSFB5- '9
Your Order Code : MEZUS 410
1. Range
0
1
0 - 0.5 ppm (Standard), 0 - 1 ppm
0 - 1 ppm, 0 - 2 ppm
3. Internal Zero
0
Z
Sample/ Cal valve (standard)
Internal Zero Scrubber
2. Power
0
A
220VAC/60Hz (standard)
230VAC/50Hz
B 110VAC/50Hz
4. Mountion Hardware
0
H
Bench mounting (standard)
Ears handles
5. Teflon Particulate filter
0 Not Include (standard)
Measuring items
Measuring method
Ranges
Lower Detectable Limit
Repeatability
Zero drift
Span drift
Response time(95%)
Linearity
Precision
Ambient temperature
Analog output
Sample flow rate
Particulate filter
Display
Comport
Internal data memory
Power requirement
Ozone(O3) in ambient air
UV Photometry (UV absorption method)
0-0.1 / 0-0.5 / 0-1 ppm (selectable)
Less than 0.5ppb
within ±1% of span gas concentration
Less than 1ppb
within ±1%/full scale (1 day)
Less than 50 seconds (T95)
within ±1%/full scale
0.5% of reading or 1ppb
5 - 40˚
C
0-1V / 0-5V or 4-20mA (option)
Stabilized flow control by 800cc/min Critical Orifice
47mm Teflon filter
7 inch Graphic LCD
Ethernet, USB1.1, RS-232
Measuring data (5min /1year), Operation history, Messages, Alert
220VAC/60Hz or 230VAC/50Hz
GdYW]Z]WUh]cbg
8]aYbg]cbg-case type
Front Back Top
540mm
426mm
590mm
CfXYf]b[=bZcfaUh]cb
220mm
479mm
p 1pkg
US EPA
Authorised Partner for India
Contact : +91 7382708685, Email:- info@vasthi.com
Manjeera Trinity Corporate, Survey No:1050,
Plot No-112, JNTU - Hitech City Road,
Kukatpally Housing Board Colony, Kukatpally,
Hyderabad, Telangana 500034