SlideShare a Scribd company logo
1 of 21
Electronic Pills
1
ACKNOWLEDGEMENT
Our special gratitude is owed to ALMIGHTY ALLAH,with whose blessings we have been able to
successfully accomplish our task.
We wish to express my sincere gratitude to my Ms. Faseeha for helping us in providing Project. She
was involved in every step of the study, help us throughout the project. And give and inordinate
time and energy to make us learn electronic pills project.
We are also grateful to the entire management of the Jinnah University, in particular to the
Chairperson Dr. Shahab siddiqui, Department of computer science and information technology for
facilitating our learning. Thanks are also extended to my group mates and class mates for his
encouragement and criticisms in bringing this study to completion. We are grateful for the assistance
of University’s Faculty and Staff to entrust us with the information to proceed with their search. We
wish to acknowledge the contributions of all those who assisted us in one way or another. Your
untiring guidance, hard work and encouragement were invaluable.
Electronic Pills
2
Table of contents
Chapter 1: Introduction-------------------------------------------------------------------------------Page No:4
1.1 Project overview------------------------------------------------------------------------------- Page No:5
1.2 Aims and objectives----------------------------------------------------------------------------Page No:5
1.3 Project scope------------------------------------------------------------------------------------ Page No:6
1.4 Project features--------------------------------------------------------------------------------- Page No:6
1.5 References--------------------------------------------------------------------------------------- Page No:7
Chapter 2:
2.1 components--------------------------------------------------------------------------------------- Page No:8
2.2 Description of Components--------------------------------------------------------------------- Page No:9
Chapter 3:
3.1 Working-------------------------------------------------------------------------------------------Page No:15
Electronic Pills
3
List of tables and description
Fig 1 block diagram---------------------------------------------------------------------------------------Page No:8
Figure 2: Sensors----------------------------------------------------------------------------------------- Page No:9
Figure 3: DT-670-SD------------------------------------------------------------------------------------ Page No:11
Figure 4: ISFET------------------------------------------------------------------------------------------ Page No:11
Fig.5: Application Specific integrated circuit control chip------------------------------------------Page No:13
Fig 6: A schematic of the architecture ---------------------------------------------------------------- Page No:13
Fig. 7: Illustrating the interface to externalComponents------------------------------------------- Page No:13
Figure 8: Capillary pore type oxygen sensor---------------------------------------------------------- Page No:17
Figure 9: Three electrode electrochemical sensor-------------------------------------------------- Page No:18
Fig. 10: pH sensor----------------------------------------------------------------------------------------- Page No:19
Fig. 11: Temperature sensor----------------------------------------------------------------------------- Page No:20
Electronic Pills
4
CHAPTER NO#1
INTRODUCTION:
Our body is a sensitive system. At some situations, doctors can’t easily detect diseases and hence it
becomes too late to cure it. Use of electronic pill helps us to easily detect the diseases and can take sudden
action against it.
Professor John Cooper and Dr. Eric Johannessen from Glasgow University, U.K has led to the
development of electronic pill. It is a medical monitoring system. Measurement parameters of electronic
pills include temperature analysis, pH measurements,conductivity and dissolved oxygen. And they can
also capture images and sent it into a system. Electronic pills are swallow able. It has a 16mm diameter, a
length of 55mm and 5gram weight. This pill is covered by chemically resistant polyether-terketone
(PEEK) coating.
Electronic Pills
5
1.1 Project Overview
A electronic pill is basically a multi channel sensor used for remote bio medical measurements using
micro technology this has been developed for the internal study and detection of diseases and
abnormalities in the gastro intestinal GI tract where restricted access prevents the use of traditional
endoscopy the measurement parameters for detection include real time remote recording of
temperature, pH, conductivity and dissolved oxygen in the GI tract This paper with the design of the
electronic pill which mainly consists of an outer biocompatible capsule encasing 4 channel micro
sensors a control chip, a discrete component radio transmitter and 2 silver oxide cells.
1.2 Aims and Objectives:
 In today’s world, it’s an exciting time for medical technology. And making smart use of modern
digital innovations is bringing revolutions in health care for the young and old.
 The ability to combine information and function from various devices to personalize treatment
based on individual conditions presents enormous opportunity to both improve health and reduce
costs. And these trends support the demands for individuals to assume greater control and
ownership of their own health state.
 One concept related to these trends is that of an electronic pill. And, although the idea of an
electronic pill has been around for decades,researchersnever quite brought this technology to
reality. That is, until now.
 Medimetrics, a Germany-based company developing electronic oral drug delivery, has brought
this idea to reality with its IntelliCap technology.
 “Our challenge was to construct and deploy a device using advanced, but available, components
and production techniques,” says Jeff Shimizu, CTO,Medimetrics in an interview with R&D
Magazine. Elements of drug, electronics, wireless communication and micromechanics had to be
combined in a way to preserve small size, reliable manufacturing and a safety profile fit for
medical use.
 “An electronic drug delivery pill presents an entirely new means of intelligent delivery and
monitoring,” says Shimizu. And this development opens the door to a wide range of applications
which are in the early stages of exploration.
Electronic Pills
6
1.3 Project Scope:
Digital devices and smart use of personalized data will bring about a revolution in health care. And while
there are many difficulties and barriers to their adoption, these excuses can longer cause us not to embrace
technologies that could have positive impacts on lives.
“The IntelliCap technology is already one important component in a future of connected
health care,”
Says Shimizu and with the push towards smart pharmaceuticals, the IntelliCap technology acts as a
bridge between the worlds of active drugs and mobile digital devices.
1.4 Project Features:
The IntelliCap system is an electronic drug delivery and monitoring device. The technology includes a
drug reservoir, delivery pump, electronic microcontroller, wireless communication and sensors.
The delivery device is constructed in a small pill-shaped capsule that is swallowed and passes through the
gastro-intestinal tract. While in the body, the capsule takes measurements of the local pH and
temperature. This data is reported by wireless RF communication to an externalunit and may be
monitored at a computer or mobile device.
Additionally, commands may be sent to the capsule while in the body. The measurements allow
localization of the IntelliCap capsule which, in turn, is used for accurate delivery of drug at specifically
targeted locations in the gastro-intestinal tract. Drug delivery is controlled by the on-board electronics
enabling both precise and adaptable delivery patterns that are not possible by other means.
Electronic Pills
7
1.5 REFERENCES
[1] R. S. Mackay,” Endpradiossonde,” Nature vol. 179, 1957
[2] G. Meron, “The development of the swallowable video capsule (M2A),” Gastrointestinal Endoscopy,
vol. 6, pp. 817-8199, 2000.
[3] M. Q. H. Meng, et al., “Wireless Robotic Capsule Endoscopy: State-of the Art and Challenges,” in the
5th World Congress on intelligent Control and Automation, 2004, vol. 6, pp. 5561-5565.
[4] http://www.givenimaging.com/ , 2009.
[5] P. Bradley, “An ultra low power, high performance medical implant communication system (MICS)
transceiver for implantable devices,” in the IEEE Biomed. Circuits and Systems Conference,pp. 158-16,
2006.
[6] J. Nagumo et al., “ Echo capsule for medical use,” IRE Transaction on Bio-medical Electronics, vol.
9., pp. 195-199, 1962.
[7] C. Mc Caffrey, et al. “ Swallowable-capsule technology,” Pervasive computing, January-March,
2008.
[8] V. K. Zworykin, “Radio pill,” Nature,vol. 179, p. 898, 1957.
[9] R. S. Mackay and B. Jacobson, “Radio telemetering from within the human body,” Science, vol. 134,
pp. 1196-1202, 1961.
[10] X. Chen et al. “A wireless capsule endoscope system with low-power controlling and processing
ASIC,” IEEE Transation on Biomedical Circuits and Systems, Vol. 3, February 2009.
[11] E. A. Johannessen, et al. “Biocompatibility of a lab-on-a-pill sensor in artificial gastrointestinal
environments,” IEEE Trans. Biomed. Eng., vol. 53, pp. 2333, Nov. 2006.
[12] P. Valdastri , A. Menciassi , A. Arena ,C. Caccamo and P. Dario “An implantable telemetry
platform system for in vivo monitoring of physiological parameters,” IEEE Trans. Inform. Technol.
Biomed., vol.8, pp. 271, Sep. 2004.
[13]www.google.nl/patents/US6632175
[14]http://www.techmezine.com/top-10-news/electronic-pills-collecting-data-inside-the-body/
[15]http://www.innovationessence.com/smart-collecting-inside/
[16]http://www.inventor-strategies.com/new-electronic-inventions.html
[17]http://muettech.com/news/electronic-pills-collecting-data-inside-the-body/
[18]https://en.wikipedia.org/wiki/Microelectronics
[19]Veendrick, H.J.M. (2011). Bits on Chips. p. 253. ISBN 978-1-61627-947-9.
https://openlibrary.org/works/OL15759799W/Bits_on_Chips/
Electronic Pills
8
CHAPTER NO#2
2.1 Components:
The design of the microelectronic pill is in the form of a capsule. The encasing it has is
biocompatible. Inside this are multi- channel (four channel) sensors and a control chip. It also comprises
of a radio transmitter and two silver oxide cells. The four sensors are mounted on the two silicon chips. In
addition to it, there are a control chip, one access channel and a radio transmitter.
The four sensors commonly used are a temperature sensor, pH ISFET sensor, a dual electrode
conductivity sensor and a three electrode electrochemical oxygen sensor. Among these the temperature
sensor, the pH ISFET sensor and the dual electrode conductivity sensor are fabricated on the first chip.
The three electrode electrochemical cell oxygen sensor will be on chip 2. The second chip also consists of
a NiCr resistance thermometer which is optional.
The basic Components of Electronic Pills are:
 Sensors
 Control Chip
 Radio Transmitters
 Silver Oxide Batteries
Fig 1 block diagram
*(1) access channel, (2) 4 sensors which are mounted on two silicon chips (Chip 1 & 2),
*(3) capsule,* (4) Rubber ring, * (5) a control chip *(6) PCB chip carrier
* (7) (9)(10) a radio transmitter (STD- type, type2-crystal)* (8) silver oxide batteries
Electronic Pills
9
2.2 Description of Components
1) Sensors
Figure 2: Sensors
There are basically 4 sensors mounted on two chips- Chip 1 & chip 2. On chip 1(shown in fig 2
a), c), e)), temperature sensor silicon diode (4), pH ISFET sensor (1) and dual electrode conductivity
sensor (3) are fabricated. Chip 2 comprises of three electrode electrochemical cell oxygen sensor (2) and
optional NiCr resistance thermometer.
Electronic Pills
10
a) Sensorchip1
An array consisting of both temperature sensor & pH sensor platforms were cut from the
wafer and attached onto 100-µm- thick glass cover slip cured on a hot plate. The plate acts as a
temporary carrier to assist handling of the device during level 1 of lithography when the electric
connection tracks, electrode bonding pads are defined. Bonding pads provide electrical contact to the
external electronic circuit.
Lithography was the first fundamentally new printing technology since the invention of relief
printing in the fifteenth century. It is a mechanical Plano graphic process in which the printing and
non-printing areas of the plate are all at the same level, as opposed to intaglio and relief processes in
which the design is cut into the printing block. Lithography is based on the chemical repellence of oil
and water. Designs are drawn or painted with greasy ink or crayons on specially prepared limestone.
The stone is moistened with water, which the stone accepts in areas not covered by the crayon. Oily
ink, applied with a roller, adheres only to the drawing and is repelled by the wet parts of the stone.
Pressing paper against the inked drawing then makes the print.
Lithography was invented by Alois Senefelder in Germany in 1798 and, within twenty years,
appeared in England and the United States. Almost immediately, attempts were made to print pictures
in color. Multiple stones were used; one for each color, and the print went through the press as many
times as there were stones. The problem for the printers was keeping the image in register, making
sure that the print would be lined up exactly each time it went through the press so that each color
would be in the correct position and the overlaying colors would merge correctly.
Early colored lithographs used one or two colors to tint the entire plate and create a water
color-like tone to the image. This atmospheric effect was primarily used for landscape or
topographical illustrations. For more detailed coloration, artists continued to rely on hand coloring
over the lithograph. Once tinted lithographs were well established, it was only a small step to extend
the range of color by the use of multiple tint blocks printed in succession. Generally, these early
chromolithographs were simple prints with flat areas of color, printed side-by-side.
Increasingly ornate designs and dozens of bright, often gaudy, colors characterized
chromolithography in the second half of the nineteenth century. Overprinting and the use of silver and
gold inks widened the range of color and design. Still a relatively expensive process,
chromolithography was used for large-scale folio works and illuminated gift books that often
attempted to reproduce the handwork of manuscripts of the Middle Ages. The steam-driven printing
press and the wider availability of inexpensive paper stock lowered production costs and made
chromolithography more affordable. By the 1880s, the process was widely used for magazines and
advertising. At the same time, however, photographic processes were being developed that would
replace lithography by the beginning of the twentieth century.
Chip 1 is divided into two- LHS unit having the temperature sensor silicon diode, while RHS
unit comprises the pH ISFET sensor.
DT-670-SD Silicon Diode Features
Electronic Pills
11
Figure 3: DT-670-SD
 It measures the body core temperature.
 Also compensates with the temperature induced signal changes in other sensors.
 It also identifies local changes associated with tissue inflammation & ulcers.
ISFET
Figure 4: ISFET
Ion Selective Field Effect Transistor ISFET; this type of electrode contains a transistor
coated with a chemically sensitive material to measure pH in solution and moist surfaces. As the
potential at the chemically active surface changes with the pH, the current induced through the
transistor varies. A temperature diode simultaneously monitors the temperature at the sensing surface.
The pH meter to a temperature compensated pH reading correlates the change in current and
temperature.
This device has an affinity for hydrogen ions, which is the basis for the determination
of the pH. The surface of the sensitive area of the sensor contains hydroxyl groups that are bound to an
oxide layer. At low pH values hydrogen ions in the sample will bind to these hydroxyl groups resulting
in a positively charged surface. In alkaline environments hydrogen ions are abstracted from the
hydroxyl groups, leading to a negatively charged surface.
Thus, each pH change has a certain influence on the surface charge. On its turn, this
attracts or repulses the electrons flowing between two electrodes in the semiconductor device. The
electronics compensates the voltage in order to keep the current between the two electrodes at its set
point. In this way this potential change is related to the pH.
Attachment of a polymer membrane on the ISFET introduces the possibility to go
beyond the measurement of pH toward other ions. In this plastic layer certain chemicals (ionophores),
which can recognize and bind the desired ion, are put in. Now, complex formations of the ionophore
Electronic Pills
12
and the ion introduce a charge. The potential change is a measure for the ion concentration. Typically,
these sensors can be used in a concentration range between app. 10.5 up to 1 mol/l.
b) Sensor Chip 2:
The level 1pattern (electric tracks, bonding pads, and electrodes) was defined in 0.9µm UV3
resist (Shipley, U.K.) by electron beam lithography. A layer of200 nm gold (including an adhesion layer
of 15 nm titanium and 15 nm palladium) was deposited by thermal evaporation. The fabrication process
was repeated (Level 2) to define the5- m-wide and 11-mm-long NiCr resistance thermometer made from a
100-nm-thick layer of NiCr (30- resistance).Level 3 defined the 500-nm-thick layer of thermal evaporated
silver used to fabricate the reference electrode. An additional sacrificial layer of titanium (20 nm)
protected the silver from oxidation in subsequent fabrication levels. The surface area Fig. 2.
Photograph of the 4:75 2 4:75 mm application specific integrated circuit control chip (a),the
associated explanatory diagram (b), and a schematic of the reference electrode was 1.5*10^-2 mm ,
whereas the of the architecture (c) illustrating the interface to external components. MUX counter
electrode made of gold had an area of mm .(four-channel multiplexer), ADC, DAC , and OSC (32-kHz
oscillator).Level 4 defined the microelectrode array of the working electrode, comprising 57 circular gold
electrodes, each 10µm in diameter, with an inter electrode spacing of 25 m and a combined area of
4.5*10^-3 mm . Such an array promotes electrode polarization and reduces response time by enhancing
transport to the electrode surface [26]. The whole wafer was covered with500 nm plasma-enhanced
chemical vapour deposited (PECVD) Si3Ni4The pads, counter, reference,and the microelectrode array of
the working electrode was exposed using an etching mask of S1818 photo resist prior to dry etching with
C2F6 . The chips were then diced from the wafer and attached to separate100- m-thick cover slips by
epoxy resin to assist handling. The electrolyte chamber was defined in 50- m-thick polyimide at Level 5.
Residual polyimide was removed in an barrel a shear(2 min), prior to removal of the sacrificial
titanium layer at Level6 in a diluted HF solution (HF to RO water, 1:26) for 15 s. The short exposure to
HF prevented damage to the PECVD layer. Thermally evaporated silver was oxidized to Ag AgCl (50%of
film thickness) by chronopotentiometry (120 nA, 300 s) at Level 7 in the presence of KCl, prior to
injection of the internal reference electrolyte at Level 8.
2) Control Chip
The ASIC (Application Specific Integrated Circuit) is the control unit that connects together other
components of the micro system. It contains an analogue signal –conditioning module operating the
sensors, 10-bit analogue to digital (ADC) & digital to analogue (DAC) converters,& digital data
processing module. The temperature circuitry bias the diode at constant current so that change in
temperature reflects a corresponding change in in diode voltage. The pH ISFET sensor is biased as a
simple source at constant current with the source voltage changing with threshold voltage & pH. The
ASIC was a control unit that connected together the external components of the micro system It was
fabricated as a 22.5 mm silicon die using a 3-V, 2-poly, 3-metal 0.6µM The conductivity circuit operates
at D.C. It measures the resistance across the electrode pair as an inverse function of solution conductivity.
An incorporated potentiostat circuit operates the O2 sensor with a 10 bit DAC controlling the working
electrode potential w.r.t the reference. Analogue signals are sequenced through a multiplexer before
Electronic Pills
13
being digitized by ADC.ASIC & sensors consume 5.3 mW power corresponding to 1.7 mA of current.
Fig.5 , the associated explanatory
diagram of4:75 2 4:75 mm application
specific integrated circuit control chip
Fig 6 a schematic ofthe architecture Fig. 7.illustrating the interface to external
Components.
Is particularly effective when the measuring environment is acquiescent, a condition encountered
in many applications The entire design was constructed with a focus on low power consumption and
immunity from noise interference. The digital module was deliberately clocked at 32 kHz and employed a
sleep mode to conserve power from the analogue module. Separate on-chip power supply trees and pad-
ring segments were used for the analogue and digital electronics sections in order to discourage noise
propagation and interference.
Electronic Pills
14
3) Radio Transmitter
The radio transmitter was assembled prior to integration in the capsule using discrete surface
mount components on a single-sided printed circuit board (PCB). The footprint of the standard transmitter
measured 8*5*3mm including the integrated coil (magnetic) antenna. It was designed to operate at a
trans-mission frequency of 40.01 MHz at 20 C generating a signal of 10 kHz bandwidth. A second crystal
stabilized transmitter was also used. This second unit was similar to the free running standard transmitter,
apart from having a larger footprint of 10*5*3mm, and a transmission frequency limited to 20.08MHz at
20 C, due to the crystal used. Pills incorporating the standard transmitter were denoted Type I, whereas
the pills in-cooperating the crystal stabilized unit were denoted Type II. The transmission range was
measured as being 1 meter and the modulation scheme frequency shift keying (FSK), with a data rate
of1Kbs^-1
4) Capsule
The microelectronic pill consisted of a machined biocompatible (noncytotoxic), chemically
resistant polyetherterket one (PEEK) capsule (Victrex, U.K.) and a PCB chip carrier acting as a common
platform for attachment of the sensors, ASIC, transmitter and the batteries (Fig. 3). The fabricated sensors
were each attached by wire bonding to a custom made chip carrier made from a 10-pin, 0.5-mm pitch
polyimide ribbon connector. The ribbon connector was, in turn, connected to an industrial standard 10-pin
flat cable plug (FCP) socket (Radio Spares, U.K.) attached to the PCB chip carrier of the microelectronic
pill, to facilitate rapid replacement of the sensors when required. The PCB chip carrier was made from
two standard1.6-mm-thick fiber glass boards attached back to back by epoxy resin which maximized the
distance between the two sensor chips. The sensor chips were connected to both sides of the PCB by
separate FCP sockets, with sensor Chip 1 facing the top face, with Chip 2 facing down. Thus, the oxygen
sensor on Chip 2 had to be connected to the top face by three 200- m copper leads soldered on to the
board. The transmitter was integrated in the PCB which also incorporated the power supply rails, the
connection points to the sensors, as well as the transmitter and the ASIC and the supporting slots for the
capsule in which the chip carrier was located. The ASIC was attached with double-sided copper
conducting tape (Agar Scientific, U.K.) prior to wire bonding to the power supply rails, the sensor inputs,
and the transmitter (a process which entailed the connection of 64 bonding pads). The unit was powered
by two standard 1.55-V SR44 silver oxide cells with a capacity of 175 mAh. The batteries were serial
connected and attached to a custom made 3-pin, 1.27-mm pitch plug well as making it easy to maintain
(e.g., during sensor and battery replacement). The complete prototype was 16.55 mm and weighted 13.5 g
including the batteries. A smaller pill suitable for physiological in vivo trials (10 30 mm) is currently
being developed from the prototype.
Electronic Pills
15
CHAPTER NO#3
3.1 WORKING
1) GeneralSetup
All the devices were powered by batteries in order to demonstrate the concept of utilizing the
microelectronic pill in remote locations (extending the range of applications from in vivo sensing to
environmental or industrial monitoring). The pill was submerged in a 250-mL glass bottle located within
a 2000-mLbeaker to allow for a rapid change of pH and temperature of the solution. A scanning receiver
(Winradio Communications, Australia) captured the wireless radio transmitted signal from the
microelectronic pill by using a coil antenna wrapped around the 2000-polypropylene beaker in which the
pill was located. A portable Pentium III computer controlled the data acquisition unit (National
Instruments, Austin, TX) which digitally acquired analogue data from the scanning receiver prior to
recording it on the computer. The solution volume used in all experiments was 250 mL The beaker,pill,
glass bottle, and antenna were located within 25*25 cm container of polystyrene, reducing temperature
fluctuations from the ambient environment (as might be expected within the GI tract) and as required to
maintain a stable transmission frequency. The data was acquired using Lab View (National Instruments,
Austin, TX) and processed using a MATLAB (Math works, Natick, MA) routine.
2) Sensing
The lifetime of the incorporated AgCl reference electrodes used in the pH and oxygen sensors
was measured with an applied current of 1 pA immersed in a 1.0 M KCl electrolyte solution. The current
reflects the bias input current of the operational amplifier in the analogue sensor control circuitry to which
the electrodes were connected The temperature sensor was calibrated with the pill submerged in reverse
osmosis (RO) water at different temperatures. The average temperature distribution over 10 min was
recorded for each measurement,represented as 9.1 C, 21.2 C, 33.5C, and 47.9 C
The system was allowed to temperature equilibrate for 5 min prior to data acquisition. The control
readings were performed with a thin wire K-type thermocouple(Radio Spares, U.K.). The signal from the
temperature sensor as investigated with respect to supply voltage potential, due to the temperature
circuitry being referenced to the negative supply rail. Temperature compensated readings (normalized
to23 C) were recorded at a supply voltage potential of 3.123,3.094, 3.071, and 2.983 mV using a direct
communication link. Bench testing of the temperature sensor from 0 C to 70 C was also performed to
investigate the linear response characteristics of the temperature sensor. The pH sensor of the
microelectronic pill was calibrated in standard pH buffers [28] of pH 2, 4, 7, 9, and 13, which reflected
the dynamic range of the sensor. The calibration was performed at room temperature (23 C) over a period
of 10 min, with the CMOS process by Austria Microsystems (AMS) via the Euro practice initiative It is a
novel mixed signal design that contains an analogue signal conditioning module operating the sensors,an
Electronic Pills
16
10-bit analogue-to-digital (ADC) and digital-to-analogue(DAC) converters, and a digital data processing
module. An RC relaxation oscillator (OSC) provides the clock signal. The analogue module was based on
the AMS OP05B operational amplifier, which offered a combination of both a power having scheme
(sleep mode) and a compact integrated circuit design.
The digital data processing module conditioned the digitized signals through the use of a serial bit
stream data compression algorithm, which decided when transmission was required by comparing the
most recent sample with the previous sampled data. This technique minimizes the transmission length,
and comprising the electronic pill. The prototype is 16 2 55 mm, weights 13.5 g.The Type I unit consist of
the microelectronic sensors at the front enclosed by the metal clamp and rubber seal(1) which provide a
3-mm-diameter access channelto the sensors (2). The front section of the capsule, physically machined
from solid PEEK,is illustrated (3) with the rear section removed to illustrate the internal design. The front
and rear section of the capsule is joined by a screw connection sealed of by a Viton-rubber o-ring (4).
The reduction potential of water was assessed in oxygen depleted PBS,to avoid interference from
oxygen, at the same time assessing the lower potential limit that could be used for maximizing the
efficiency of the sensor. The voltage was then fixed above this reduction potential to assess the dynamic
behavior of the sensor upon injection of saturated in oxygen saturated PBS.
3) Oxygen detection by Sensor.
Most portable or survey instruments used for workplace evaluation of oxygen
concentrations make use of "fuel cell" type oxygen sensors. "Fuel cell" oxygen sensors consist of a
diffusionbarrier,asensingelectrode (cathode) made of anoble metal suchasgold or platinum, and a
workingelectrode made of abase metal suchas leador zincimmersedinabasic electrolyte(suchasa
solution of potassium hydroxide).
Oxygen diffusing into the sensor is reduced to hydroxyl ions at the cathode:
O2 + 2H2O + 4e-
OH –
Hydroxyl ions in turn oxidize the lead (or zinc) anode:
2Pb + 4OH 2PbO + 2H2O + 4e –
This yields an overall cell reaction of:
2Pb + O2 2PbO
Fuel cell oxygen sensors are current generators. The amount of current generated is
proportional to the amount of oxygen consumed (Faraday's Law). Oxygen reading instruments simply
monitor the current output of the sensor.
An important consideration is that fuel cell oxygen sensors are used up over time. In
the cell reaction above, when all available surface area of the lead (Pb) anode has been converted to
lead oxide (PbO), electrochemical activity ceases, current output falls to zero, and the sensor must be
rebuilt or replaced. Fuel cell sensors are designed to last no more than one to two years. Even when
Electronic Pills
17
installed in an instrument which is never turned on, oxygen sensors which are exposed to atmosphere
which contains oxygen are generating current, and being used up.
Oxygen sensors are also influenced by the temperature of the atmosphere they are
being used to measure. The warmer the atmosphere, the faster the electrochemical reaction. For this
reason oxygen sensors usually include a temperature compensating load resistor to hold current output
steady in the case of fluctuating temperature. (Microprocessor based instrument designs usually
provide additional signal correction in software to further improve accuracy.) Another limiting factor is
cold. The freezing temperature of electrolyte mixtures commonly used in oxygen sensors tends to be
about 5o
F (-20o
C). Once the electrolyte has frozen solid, electrical output falls to zero, and readings
may no longer be obtained. There are two basic variations on the fuel cell oxygen sensor design. These
variations have to do with the mechanism by which oxygen is allowed to diffuse into the sensor.
Dalton's Law states that the total pressure exerted by a mixture of gases is equal to the sum of the
partial pressures of the various gases.
Figure 8: Capillary pore type oxygen sensor
Effects of contaminants on oxygen sensors
Oxygen sensors may be affected by prolonged exposure to "acid" gases such as carbon dioxide. Most
oxygen sensors are not recommended for continuous use in atmospheres which contain more than
25% CO 2.
Substance-specific electrochemical sensors
One of the most useful detection techniques for toxic contaminants is the use of substance-specific
electrochemical sensors installed in compact, field portable survey instruments. Substance-specific
electrochemical sensors consist of a diffusion barrier which is porous to gas but nonporous to liquid,
reservoir of acid electrolyte (usually sulphuric or phosphoric acid), sensing electrode, counter
electrode, and (in three electrode designs) a third reference electrode. Gas diffusing into the sensor
reacts at the surface of the sensing electrode. The sensing electrode is made to catalyze a specific
reaction. Dependent on the sensor and the gas being measured, gas diffusing into the sensor is either
oxidized or reduced at the surface of the sensing electrode. This reaction causes the potential of the
Electronic Pills
18
sensing electrode to rise or fall with respect to the counter electrode. The current generated is
proportional to the amount of reactant gas present.
This two electrode detection principle presupposes that the potential of the counter
electrode remains constant. In reality, the surface reactions at each electrode causes them to polarize,
and significantly limits the concentrations of reactant gas they can be used to measure. In three
electrode designs it is the difference between the sensing and reference electrode which is what is
actually measured. Since the reference electrode is shielded from any reaction, it maintains a constant
potential which provides a true point of comparison. With this arrangement the change in potential of
the sensing electrode is due solely to the concentration of the reactant gas.
Figure 9: Three electrode electrochemical sensor
4) Transmission
The pill’s transmission frequency was measured with respect to changes in temperature. The
Type I pill (without crystal) was submerged in RO water at temperatures of 1 C, 11 C, 23 C,and 49 C,
whereas the Type II pill (with crystal) was submerged in temperatures of 2 C, 25 C, and 45 C. The change
in frequency was measured with the scanning receiver, and the results used to assess the advantage of
crystals stabilized units at the cost of a larger physical size of the transmitter.
 Dynamic Measurements
Dynamic pH measurements were performed with the pill submerged in a PBS solution at 23 C.
The pH was changed from the initial value of 7.3 by the titration of 0.1 M Hand0.1 MNaOH,respectively.
Subsequently, the pH was changed from pH 7.3 to pH 5.5 (after 5 min), pH 3.4 (after 8 min) top 9.9 (after
14 min) and back to pH 7.7 (after 21 min). A standard (bench-top) pH electrode monitored the pH of the
solution. The solutions were sampled after the pH change, and measured outside the experimental system
to prevent electronic noise injection from the pH electrode. The temperature channel was recorded
Electronic Pills
19
simultaneously.
5) Sensorand Signal Drift
Long term static pH and temperature measurements were performed to assess signal drift and
sensor lifetime in physiological electrolyte (0.9% saline) solutions. A temperature of 36.5 Cwas achieved
using a water bath, with the assay solutions continuously stirred and re-circulated using a peristaltic
pump. The sensors were transferred from solutions of pH 4 to pH 7, within2 h of commencing the
experiment, and from pH 7 to pH 10.5.
Fig. 10.pH sensor: (a) pH recording in the range ofpH 2 to 13, represented by digital data
points; (b) dynamic recording oftemperature (1) and pH (2) using a direct communication link
illustrates the temperature sensitivity ofthe pH channel.
Electronic Pills
20
Fig. 11 Temperature sensor: (a) temperature recording over a range from 9.1 C to 47.9 C,
represented by digital data points; (b) high-resolution plot ofa temperature change from 49.8 C to
48.7 C.
The control measurement from the thermocouples is presented as solid points with error bars
representing the resolution of the thermometer. The resolution of the temperature channel was noise
limited to 0.4 C(16:8 mV C),whereas the temperature channel is insensitive to any pH is chanced use the
temperature channel to drift. Thus, bench test measurements conducted on the temperature sensor
revealed that the output signal changed by 1.45 mV per mV change in supply voltage ( (mV)-1.4Mv
expressed in mill volts, corresponding to a drift of -21mVin the pill from a supply voltage change of-
14.5Mv
Electronic Pills
21
6) RESULTS
The power consumption of the microelectronic pill with the transmitter, ASIC and the sensors
connected was calculated to12.1 mW, corresponding to the measured current consumption of 3.9 mA at
3.1-V supply voltage. The ASIC and sensors consumed 5.3 mW, corresponding to 1.7 mA of current,
whereas the free running radio transmitter (Type I) consumed 6.8 mW(-corresponding to 2.2 mA of
current) with the crystal stabilized unit (Type II) consuming 2.1 mA. Two SR44bat-teries used provided
an operating time of more than 40 h for the micro system.
7) DISCUSSION
Capsules as Actuators
Drug delivery system is an issue of optimization for many interests, immediate release
drug will be absorbed in the upper part of the small intestine after stomach, extended release drug is
desired to be absorbed in the lower level of the intestine. Achievement of the second by normal
coating tablets is difficult due to the complexity of the GI tract of human being, intubations is an
alternative solution, but it is uncomfortable for patients. Alternative solution will be of more interest,
and the idea of developing swallowed capsules devices was , over two decades engineers are trying
to develop different capsules with the capability to control the time and the location of the drug
release. The earlier capsules in this domain were HF,Indelicate, and Telemetric Capsules. They are
triggered by a radio frequency (RF) pulse from a generator outside body, the heat generated in
the circuit will melt a thread releasing a needle that pierces the container and spells out the drug.
State-of-the-art in this domain are the Enterion™ capsule and ChipRxThe patient must undergo several
gamma scans to identify the location. Telemetric capsule uses a cogwheel means for localization.
Enhancement in localization is of more interest and more work can be done in this domain to achieve a
practical solution for position determination
Capsules as Sensors
Monitoring the variation of temperature, pH, motility and other functions are getting easier and
comfortable for patients. The need to collect biomedical information within a specific location is of
high interest, most of the existing sensor capsules don’t provide location determination. Earlier
products in this field are the Radio Pill, BRAVO, Heidelberg and Temperature capsules. Almost all
of them use internal battery for power consumption. New capsules in this field are A newplatform
of an electronic pill with bidirectional communication system for miniaturized and low power
biomedical applications

More Related Content

What's hot

IRJET - Real Time Dementia Prediction System using Internet of Thing
IRJET - Real Time Dementia Prediction System using Internet of ThingIRJET - Real Time Dementia Prediction System using Internet of Thing
IRJET - Real Time Dementia Prediction System using Internet of ThingIRJET Journal
 
Ece 375-wcomp-introduction-to-wearable-computing-dr. rajiv ranajn singh (1)
Ece 375-wcomp-introduction-to-wearable-computing-dr. rajiv ranajn singh (1)Ece 375-wcomp-introduction-to-wearable-computing-dr. rajiv ranajn singh (1)
Ece 375-wcomp-introduction-to-wearable-computing-dr. rajiv ranajn singh (1)PresidencyUniversity
 
Automatic and low cost saline level monitoring system using wireless bluetoot...
Automatic and low cost saline level monitoring system using wireless bluetoot...Automatic and low cost saline level monitoring system using wireless bluetoot...
Automatic and low cost saline level monitoring system using wireless bluetoot...eSAT Journals
 
A Biomedical Smart Sensor for Visually impaired
A Biomedical Smart Sensor for Visually impairedA Biomedical Smart Sensor for Visually impaired
A Biomedical Smart Sensor for Visually impairedDinesh Mv
 
A wearable device for machine learning based elderly's activity tracking and ...
A wearable device for machine learning based elderly's activity tracking and ...A wearable device for machine learning based elderly's activity tracking and ...
A wearable device for machine learning based elderly's activity tracking and ...journalBEEI
 
IRJET- Health Monitoring system using IoT
IRJET- Health Monitoring system using IoTIRJET- Health Monitoring system using IoT
IRJET- Health Monitoring system using IoTIRJET Journal
 
Wave_Consulting_Proposal_FINAL
Wave_Consulting_Proposal_FINALWave_Consulting_Proposal_FINAL
Wave_Consulting_Proposal_FINALMykalah Sundquist
 
Real Time ECG and Saline Level Monitoring System Using Arduino UNO Processor
Real Time ECG and Saline Level Monitoring System Using Arduino UNO ProcessorReal Time ECG and Saline Level Monitoring System Using Arduino UNO Processor
Real Time ECG and Saline Level Monitoring System Using Arduino UNO ProcessorAssociate Professor in VSB Coimbatore
 
Implementation of electronic stethoscope for online remote monitoring with mo...
Implementation of electronic stethoscope for online remote monitoring with mo...Implementation of electronic stethoscope for online remote monitoring with mo...
Implementation of electronic stethoscope for online remote monitoring with mo...journalBEEI
 
IRJET- Wireless Healthcare Monitoring using Android Phones
IRJET- Wireless Healthcare Monitoring using Android PhonesIRJET- Wireless Healthcare Monitoring using Android Phones
IRJET- Wireless Healthcare Monitoring using Android PhonesIRJET Journal
 
Life Technologies' Journey to the Cloud (ENT208) | AWS re:Invent 2013
Life Technologies' Journey to the Cloud (ENT208) | AWS re:Invent 2013Life Technologies' Journey to the Cloud (ENT208) | AWS re:Invent 2013
Life Technologies' Journey to the Cloud (ENT208) | AWS re:Invent 2013Amazon Web Services
 
A Low Power Wearable Physiological Parameter Monitoring System
A Low Power Wearable Physiological Parameter Monitoring SystemA Low Power Wearable Physiological Parameter Monitoring System
A Low Power Wearable Physiological Parameter Monitoring Systemijsrd.com
 
IRJET- An Efficient Health Care System for Human Anatomy using IoT
IRJET- An Efficient Health Care System for Human Anatomy using IoTIRJET- An Efficient Health Care System for Human Anatomy using IoT
IRJET- An Efficient Health Care System for Human Anatomy using IoTIRJET Journal
 
RECENT ADVANCES IN WEARABLE SENSORS
RECENT ADVANCES IN WEARABLE SENSORSRECENT ADVANCES IN WEARABLE SENSORS
RECENT ADVANCES IN WEARABLE SENSORSjibinknm
 
Body sensor networks: challenges & applications
Body sensor networks: challenges & applicationsBody sensor networks: challenges & applications
Body sensor networks: challenges & applicationsVasily Ryzhonkov
 
Startups Step Up - how healthcare ai startups are taking action during covid-...
Startups Step Up - how healthcare ai startups are taking action during covid-...Startups Step Up - how healthcare ai startups are taking action during covid-...
Startups Step Up - how healthcare ai startups are taking action during covid-...Renee Yao
 

What's hot (20)

CNC upgradation
CNC upgradationCNC upgradation
CNC upgradation
 
IRJET - Real Time Dementia Prediction System using Internet of Thing
IRJET - Real Time Dementia Prediction System using Internet of ThingIRJET - Real Time Dementia Prediction System using Internet of Thing
IRJET - Real Time Dementia Prediction System using Internet of Thing
 
Ece 375-wcomp-introduction-to-wearable-computing-dr. rajiv ranajn singh (1)
Ece 375-wcomp-introduction-to-wearable-computing-dr. rajiv ranajn singh (1)Ece 375-wcomp-introduction-to-wearable-computing-dr. rajiv ranajn singh (1)
Ece 375-wcomp-introduction-to-wearable-computing-dr. rajiv ranajn singh (1)
 
Automatic and low cost saline level monitoring system using wireless bluetoot...
Automatic and low cost saline level monitoring system using wireless bluetoot...Automatic and low cost saline level monitoring system using wireless bluetoot...
Automatic and low cost saline level monitoring system using wireless bluetoot...
 
A Biomedical Smart Sensor for Visually impaired
A Biomedical Smart Sensor for Visually impairedA Biomedical Smart Sensor for Visually impaired
A Biomedical Smart Sensor for Visually impaired
 
A wearable device for machine learning based elderly's activity tracking and ...
A wearable device for machine learning based elderly's activity tracking and ...A wearable device for machine learning based elderly's activity tracking and ...
A wearable device for machine learning based elderly's activity tracking and ...
 
IRJET- Health Monitoring system using IoT
IRJET- Health Monitoring system using IoTIRJET- Health Monitoring system using IoT
IRJET- Health Monitoring system using IoT
 
Wave_Consulting_Proposal_FINAL
Wave_Consulting_Proposal_FINALWave_Consulting_Proposal_FINAL
Wave_Consulting_Proposal_FINAL
 
Real Time ECG and Saline Level Monitoring System Using Arduino UNO Processor
Real Time ECG and Saline Level Monitoring System Using Arduino UNO ProcessorReal Time ECG and Saline Level Monitoring System Using Arduino UNO Processor
Real Time ECG and Saline Level Monitoring System Using Arduino UNO Processor
 
Implementation of electronic stethoscope for online remote monitoring with mo...
Implementation of electronic stethoscope for online remote monitoring with mo...Implementation of electronic stethoscope for online remote monitoring with mo...
Implementation of electronic stethoscope for online remote monitoring with mo...
 
IRJET- Wireless Healthcare Monitoring using Android Phones
IRJET- Wireless Healthcare Monitoring using Android PhonesIRJET- Wireless Healthcare Monitoring using Android Phones
IRJET- Wireless Healthcare Monitoring using Android Phones
 
Life Technologies' Journey to the Cloud (ENT208) | AWS re:Invent 2013
Life Technologies' Journey to the Cloud (ENT208) | AWS re:Invent 2013Life Technologies' Journey to the Cloud (ENT208) | AWS re:Invent 2013
Life Technologies' Journey to the Cloud (ENT208) | AWS re:Invent 2013
 
Cs35531534
Cs35531534Cs35531534
Cs35531534
 
A Low Power Wearable Physiological Parameter Monitoring System
A Low Power Wearable Physiological Parameter Monitoring SystemA Low Power Wearable Physiological Parameter Monitoring System
A Low Power Wearable Physiological Parameter Monitoring System
 
IRJET- An Efficient Health Care System for Human Anatomy using IoT
IRJET- An Efficient Health Care System for Human Anatomy using IoTIRJET- An Efficient Health Care System for Human Anatomy using IoT
IRJET- An Efficient Health Care System for Human Anatomy using IoT
 
Smart sensor technology in healthcare & protection
Smart sensor technology in healthcare & protectionSmart sensor technology in healthcare & protection
Smart sensor technology in healthcare & protection
 
RECENT ADVANCES IN WEARABLE SENSORS
RECENT ADVANCES IN WEARABLE SENSORSRECENT ADVANCES IN WEARABLE SENSORS
RECENT ADVANCES IN WEARABLE SENSORS
 
New ppt
New pptNew ppt
New ppt
 
Body sensor networks: challenges & applications
Body sensor networks: challenges & applicationsBody sensor networks: challenges & applications
Body sensor networks: challenges & applications
 
Startups Step Up - how healthcare ai startups are taking action during covid-...
Startups Step Up - how healthcare ai startups are taking action during covid-...Startups Step Up - how healthcare ai startups are taking action during covid-...
Startups Step Up - how healthcare ai startups are taking action during covid-...
 

Similar to R eport final

Bioelectronics The Revolutionary Concept
Bioelectronics The Revolutionary ConceptBioelectronics The Revolutionary Concept
Bioelectronics The Revolutionary Conceptijtsrd
 
IRJET - Digital Pill Box using Arduino
IRJET - Digital Pill Box using ArduinoIRJET - Digital Pill Box using Arduino
IRJET - Digital Pill Box using ArduinoIRJET Journal
 
Smart Pill Reminder and Monitoring System
Smart Pill Reminder and Monitoring SystemSmart Pill Reminder and Monitoring System
Smart Pill Reminder and Monitoring SystemIRJET Journal
 
A Review On Micro Electronic Pill
A Review On Micro Electronic PillA Review On Micro Electronic Pill
A Review On Micro Electronic PillHeather Strinden
 
IOT_BASED_PATIENT_MONITORING_SYSTEM_Anan.docx
IOT_BASED_PATIENT_MONITORING_SYSTEM_Anan.docxIOT_BASED_PATIENT_MONITORING_SYSTEM_Anan.docx
IOT_BASED_PATIENT_MONITORING_SYSTEM_Anan.docxhashelectrolabs
 
seminar report iot based health monitoring system 2023.pdf
seminar report  iot based health monitoring system 2023.pdfseminar report  iot based health monitoring system 2023.pdf
seminar report iot based health monitoring system 2023.pdfriddheshbore97
 
Iot based intelligent medicine box 1
Iot based intelligent medicine box 1Iot based intelligent medicine box 1
Iot based intelligent medicine box 1sidsingh680
 
Survey of IOT based Patient Health Monitoring System
Survey of IOT based Patient Health Monitoring SystemSurvey of IOT based Patient Health Monitoring System
Survey of IOT based Patient Health Monitoring Systemdbpublications
 
Automated Medicine Dispenser using IoT Technology
Automated Medicine Dispenser using IoT TechnologyAutomated Medicine Dispenser using IoT Technology
Automated Medicine Dispenser using IoT TechnologyIRJET Journal
 
Interenet of Things Based Cloud for Healthcare Network
Interenet of Things Based Cloud for Healthcare NetworkInterenet of Things Based Cloud for Healthcare Network
Interenet of Things Based Cloud for Healthcare NetworkIstabraq M. Al-Joboury
 
Telemedicine in Clinical Research
Telemedicine in Clinical ResearchTelemedicine in Clinical Research
Telemedicine in Clinical ResearchClinosolIndia
 
The Future of mHealth - Jay Srini - March 2011
The Future of mHealth - Jay Srini - March 2011The Future of mHealth - Jay Srini - March 2011
The Future of mHealth - Jay Srini - March 2011LifeWIRE Corp
 
Smart health monitoring system using IoT based smart fitness mirror
Smart health monitoring system using IoT based smart fitness mirrorSmart health monitoring system using IoT based smart fitness mirror
Smart health monitoring system using IoT based smart fitness mirrorTELKOMNIKA JOURNAL
 
IRJET- Review Paper on IoT Driven Smart Pill Box
IRJET-  	  Review Paper on IoT Driven Smart Pill BoxIRJET-  	  Review Paper on IoT Driven Smart Pill Box
IRJET- Review Paper on IoT Driven Smart Pill BoxIRJET Journal
 
IOT-Based Medicine Reminder and Monitoring System for Safe Health
IOT-Based Medicine Reminder and Monitoring System for Safe HealthIOT-Based Medicine Reminder and Monitoring System for Safe Health
IOT-Based Medicine Reminder and Monitoring System for Safe HealthIRJET Journal
 
Biochips seminar report
Biochips seminar reportBiochips seminar report
Biochips seminar reportGolam Murshid
 
Solar energy based blockchain enabled health care monitoring using IoT
Solar energy based blockchain enabled health care monitoring using IoTSolar energy based blockchain enabled health care monitoring using IoT
Solar energy based blockchain enabled health care monitoring using IoTIRJET Journal
 
February_2024 Top 10 Read Articles in Computer Networks & Communications.pdf
February_2024 Top 10 Read Articles in Computer Networks & Communications.pdfFebruary_2024 Top 10 Read Articles in Computer Networks & Communications.pdf
February_2024 Top 10 Read Articles in Computer Networks & Communications.pdfIJCNCJournal
 
“Detection of Diseases using Machine Learning”
“Detection of Diseases using Machine Learning”“Detection of Diseases using Machine Learning”
“Detection of Diseases using Machine Learning”IRJET Journal
 

Similar to R eport final (20)

Bioelectronics The Revolutionary Concept
Bioelectronics The Revolutionary ConceptBioelectronics The Revolutionary Concept
Bioelectronics The Revolutionary Concept
 
IRJET - Digital Pill Box using Arduino
IRJET - Digital Pill Box using ArduinoIRJET - Digital Pill Box using Arduino
IRJET - Digital Pill Box using Arduino
 
Smart Pill Reminder and Monitoring System
Smart Pill Reminder and Monitoring SystemSmart Pill Reminder and Monitoring System
Smart Pill Reminder and Monitoring System
 
A Review On Micro Electronic Pill
A Review On Micro Electronic PillA Review On Micro Electronic Pill
A Review On Micro Electronic Pill
 
IOT_BASED_PATIENT_MONITORING_SYSTEM_Anan.docx
IOT_BASED_PATIENT_MONITORING_SYSTEM_Anan.docxIOT_BASED_PATIENT_MONITORING_SYSTEM_Anan.docx
IOT_BASED_PATIENT_MONITORING_SYSTEM_Anan.docx
 
seminar report iot based health monitoring system 2023.pdf
seminar report  iot based health monitoring system 2023.pdfseminar report  iot based health monitoring system 2023.pdf
seminar report iot based health monitoring system 2023.pdf
 
Iot based intelligent medicine box 1
Iot based intelligent medicine box 1Iot based intelligent medicine box 1
Iot based intelligent medicine box 1
 
Survey of IOT based Patient Health Monitoring System
Survey of IOT based Patient Health Monitoring SystemSurvey of IOT based Patient Health Monitoring System
Survey of IOT based Patient Health Monitoring System
 
Automated Medicine Dispenser using IoT Technology
Automated Medicine Dispenser using IoT TechnologyAutomated Medicine Dispenser using IoT Technology
Automated Medicine Dispenser using IoT Technology
 
Interenet of Things Based Cloud for Healthcare Network
Interenet of Things Based Cloud for Healthcare NetworkInterenet of Things Based Cloud for Healthcare Network
Interenet of Things Based Cloud for Healthcare Network
 
Telemedicine in Clinical Research
Telemedicine in Clinical ResearchTelemedicine in Clinical Research
Telemedicine in Clinical Research
 
The Future of mHealth - Jay Srini - March 2011
The Future of mHealth - Jay Srini - March 2011The Future of mHealth - Jay Srini - March 2011
The Future of mHealth - Jay Srini - March 2011
 
Smart health monitoring system using IoT based smart fitness mirror
Smart health monitoring system using IoT based smart fitness mirrorSmart health monitoring system using IoT based smart fitness mirror
Smart health monitoring system using IoT based smart fitness mirror
 
IRJET- Review Paper on IoT Driven Smart Pill Box
IRJET-  	  Review Paper on IoT Driven Smart Pill BoxIRJET-  	  Review Paper on IoT Driven Smart Pill Box
IRJET- Review Paper on IoT Driven Smart Pill Box
 
IOT-Based Medicine Reminder and Monitoring System for Safe Health
IOT-Based Medicine Reminder and Monitoring System for Safe HealthIOT-Based Medicine Reminder and Monitoring System for Safe Health
IOT-Based Medicine Reminder and Monitoring System for Safe Health
 
Open Labs brief
Open Labs briefOpen Labs brief
Open Labs brief
 
Biochips seminar report
Biochips seminar reportBiochips seminar report
Biochips seminar report
 
Solar energy based blockchain enabled health care monitoring using IoT
Solar energy based blockchain enabled health care monitoring using IoTSolar energy based blockchain enabled health care monitoring using IoT
Solar energy based blockchain enabled health care monitoring using IoT
 
February_2024 Top 10 Read Articles in Computer Networks & Communications.pdf
February_2024 Top 10 Read Articles in Computer Networks & Communications.pdfFebruary_2024 Top 10 Read Articles in Computer Networks & Communications.pdf
February_2024 Top 10 Read Articles in Computer Networks & Communications.pdf
 
“Detection of Diseases using Machine Learning”
“Detection of Diseases using Machine Learning”“Detection of Diseases using Machine Learning”
“Detection of Diseases using Machine Learning”
 

Recently uploaded

Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptxOrlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptxMuhammadAsimMuhammad6
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptDineshKumar4165
 
Moment Distribution Method For Btech Civil
Moment Distribution Method For Btech CivilMoment Distribution Method For Btech Civil
Moment Distribution Method For Btech CivilVinayVitekari
 
kiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal loadkiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal loadhamedmustafa094
 
Introduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaIntroduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaOmar Fathy
 
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
COST-EFFETIVE  and Energy Efficient BUILDINGS ptxCOST-EFFETIVE  and Energy Efficient BUILDINGS ptx
COST-EFFETIVE and Energy Efficient BUILDINGS ptxJIT KUMAR GUPTA
 
Unleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leapUnleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leapRishantSharmaFr
 
PE 459 LECTURE 2- natural gas basic concepts and properties
PE 459 LECTURE 2- natural gas basic concepts and propertiesPE 459 LECTURE 2- natural gas basic concepts and properties
PE 459 LECTURE 2- natural gas basic concepts and propertiessarkmank1
 
Online electricity billing project report..pdf
Online electricity billing project report..pdfOnline electricity billing project report..pdf
Online electricity billing project report..pdfKamal Acharya
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXssuser89054b
 
Engineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planesEngineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planesRAJNEESHKUMAR341697
 
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdfAldoGarca30
 
data_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfdata_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfJiananWang21
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VDineshKumar4165
 
AIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech studentsAIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech studentsvanyagupta248
 
"Lesotho Leaps Forward: A Chronicle of Transformative Developments"
"Lesotho Leaps Forward: A Chronicle of Transformative Developments""Lesotho Leaps Forward: A Chronicle of Transformative Developments"
"Lesotho Leaps Forward: A Chronicle of Transformative Developments"mphochane1998
 
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best ServiceTamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Servicemeghakumariji156
 

Recently uploaded (20)

Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptxOrlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.ppt
 
Moment Distribution Method For Btech Civil
Moment Distribution Method For Btech CivilMoment Distribution Method For Btech Civil
Moment Distribution Method For Btech Civil
 
kiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal loadkiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal load
 
Introduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaIntroduction to Serverless with AWS Lambda
Introduction to Serverless with AWS Lambda
 
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
COST-EFFETIVE  and Energy Efficient BUILDINGS ptxCOST-EFFETIVE  and Energy Efficient BUILDINGS ptx
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
 
Unleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leapUnleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leap
 
PE 459 LECTURE 2- natural gas basic concepts and properties
PE 459 LECTURE 2- natural gas basic concepts and propertiesPE 459 LECTURE 2- natural gas basic concepts and properties
PE 459 LECTURE 2- natural gas basic concepts and properties
 
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced LoadsFEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
 
Online electricity billing project report..pdf
Online electricity billing project report..pdfOnline electricity billing project report..pdf
Online electricity billing project report..pdf
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
 
Engineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planesEngineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planes
 
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
 
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
 
data_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfdata_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdf
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - V
 
Integrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - NeometrixIntegrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - Neometrix
 
AIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech studentsAIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech students
 
"Lesotho Leaps Forward: A Chronicle of Transformative Developments"
"Lesotho Leaps Forward: A Chronicle of Transformative Developments""Lesotho Leaps Forward: A Chronicle of Transformative Developments"
"Lesotho Leaps Forward: A Chronicle of Transformative Developments"
 
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best ServiceTamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
 

R eport final

  • 1. Electronic Pills 1 ACKNOWLEDGEMENT Our special gratitude is owed to ALMIGHTY ALLAH,with whose blessings we have been able to successfully accomplish our task. We wish to express my sincere gratitude to my Ms. Faseeha for helping us in providing Project. She was involved in every step of the study, help us throughout the project. And give and inordinate time and energy to make us learn electronic pills project. We are also grateful to the entire management of the Jinnah University, in particular to the Chairperson Dr. Shahab siddiqui, Department of computer science and information technology for facilitating our learning. Thanks are also extended to my group mates and class mates for his encouragement and criticisms in bringing this study to completion. We are grateful for the assistance of University’s Faculty and Staff to entrust us with the information to proceed with their search. We wish to acknowledge the contributions of all those who assisted us in one way or another. Your untiring guidance, hard work and encouragement were invaluable.
  • 2. Electronic Pills 2 Table of contents Chapter 1: Introduction-------------------------------------------------------------------------------Page No:4 1.1 Project overview------------------------------------------------------------------------------- Page No:5 1.2 Aims and objectives----------------------------------------------------------------------------Page No:5 1.3 Project scope------------------------------------------------------------------------------------ Page No:6 1.4 Project features--------------------------------------------------------------------------------- Page No:6 1.5 References--------------------------------------------------------------------------------------- Page No:7 Chapter 2: 2.1 components--------------------------------------------------------------------------------------- Page No:8 2.2 Description of Components--------------------------------------------------------------------- Page No:9 Chapter 3: 3.1 Working-------------------------------------------------------------------------------------------Page No:15
  • 3. Electronic Pills 3 List of tables and description Fig 1 block diagram---------------------------------------------------------------------------------------Page No:8 Figure 2: Sensors----------------------------------------------------------------------------------------- Page No:9 Figure 3: DT-670-SD------------------------------------------------------------------------------------ Page No:11 Figure 4: ISFET------------------------------------------------------------------------------------------ Page No:11 Fig.5: Application Specific integrated circuit control chip------------------------------------------Page No:13 Fig 6: A schematic of the architecture ---------------------------------------------------------------- Page No:13 Fig. 7: Illustrating the interface to externalComponents------------------------------------------- Page No:13 Figure 8: Capillary pore type oxygen sensor---------------------------------------------------------- Page No:17 Figure 9: Three electrode electrochemical sensor-------------------------------------------------- Page No:18 Fig. 10: pH sensor----------------------------------------------------------------------------------------- Page No:19 Fig. 11: Temperature sensor----------------------------------------------------------------------------- Page No:20
  • 4. Electronic Pills 4 CHAPTER NO#1 INTRODUCTION: Our body is a sensitive system. At some situations, doctors can’t easily detect diseases and hence it becomes too late to cure it. Use of electronic pill helps us to easily detect the diseases and can take sudden action against it. Professor John Cooper and Dr. Eric Johannessen from Glasgow University, U.K has led to the development of electronic pill. It is a medical monitoring system. Measurement parameters of electronic pills include temperature analysis, pH measurements,conductivity and dissolved oxygen. And they can also capture images and sent it into a system. Electronic pills are swallow able. It has a 16mm diameter, a length of 55mm and 5gram weight. This pill is covered by chemically resistant polyether-terketone (PEEK) coating.
  • 5. Electronic Pills 5 1.1 Project Overview A electronic pill is basically a multi channel sensor used for remote bio medical measurements using micro technology this has been developed for the internal study and detection of diseases and abnormalities in the gastro intestinal GI tract where restricted access prevents the use of traditional endoscopy the measurement parameters for detection include real time remote recording of temperature, pH, conductivity and dissolved oxygen in the GI tract This paper with the design of the electronic pill which mainly consists of an outer biocompatible capsule encasing 4 channel micro sensors a control chip, a discrete component radio transmitter and 2 silver oxide cells. 1.2 Aims and Objectives:  In today’s world, it’s an exciting time for medical technology. And making smart use of modern digital innovations is bringing revolutions in health care for the young and old.  The ability to combine information and function from various devices to personalize treatment based on individual conditions presents enormous opportunity to both improve health and reduce costs. And these trends support the demands for individuals to assume greater control and ownership of their own health state.  One concept related to these trends is that of an electronic pill. And, although the idea of an electronic pill has been around for decades,researchersnever quite brought this technology to reality. That is, until now.  Medimetrics, a Germany-based company developing electronic oral drug delivery, has brought this idea to reality with its IntelliCap technology.  “Our challenge was to construct and deploy a device using advanced, but available, components and production techniques,” says Jeff Shimizu, CTO,Medimetrics in an interview with R&D Magazine. Elements of drug, electronics, wireless communication and micromechanics had to be combined in a way to preserve small size, reliable manufacturing and a safety profile fit for medical use.  “An electronic drug delivery pill presents an entirely new means of intelligent delivery and monitoring,” says Shimizu. And this development opens the door to a wide range of applications which are in the early stages of exploration.
  • 6. Electronic Pills 6 1.3 Project Scope: Digital devices and smart use of personalized data will bring about a revolution in health care. And while there are many difficulties and barriers to their adoption, these excuses can longer cause us not to embrace technologies that could have positive impacts on lives. “The IntelliCap technology is already one important component in a future of connected health care,” Says Shimizu and with the push towards smart pharmaceuticals, the IntelliCap technology acts as a bridge between the worlds of active drugs and mobile digital devices. 1.4 Project Features: The IntelliCap system is an electronic drug delivery and monitoring device. The technology includes a drug reservoir, delivery pump, electronic microcontroller, wireless communication and sensors. The delivery device is constructed in a small pill-shaped capsule that is swallowed and passes through the gastro-intestinal tract. While in the body, the capsule takes measurements of the local pH and temperature. This data is reported by wireless RF communication to an externalunit and may be monitored at a computer or mobile device. Additionally, commands may be sent to the capsule while in the body. The measurements allow localization of the IntelliCap capsule which, in turn, is used for accurate delivery of drug at specifically targeted locations in the gastro-intestinal tract. Drug delivery is controlled by the on-board electronics enabling both precise and adaptable delivery patterns that are not possible by other means.
  • 7. Electronic Pills 7 1.5 REFERENCES [1] R. S. Mackay,” Endpradiossonde,” Nature vol. 179, 1957 [2] G. Meron, “The development of the swallowable video capsule (M2A),” Gastrointestinal Endoscopy, vol. 6, pp. 817-8199, 2000. [3] M. Q. H. Meng, et al., “Wireless Robotic Capsule Endoscopy: State-of the Art and Challenges,” in the 5th World Congress on intelligent Control and Automation, 2004, vol. 6, pp. 5561-5565. [4] http://www.givenimaging.com/ , 2009. [5] P. Bradley, “An ultra low power, high performance medical implant communication system (MICS) transceiver for implantable devices,” in the IEEE Biomed. Circuits and Systems Conference,pp. 158-16, 2006. [6] J. Nagumo et al., “ Echo capsule for medical use,” IRE Transaction on Bio-medical Electronics, vol. 9., pp. 195-199, 1962. [7] C. Mc Caffrey, et al. “ Swallowable-capsule technology,” Pervasive computing, January-March, 2008. [8] V. K. Zworykin, “Radio pill,” Nature,vol. 179, p. 898, 1957. [9] R. S. Mackay and B. Jacobson, “Radio telemetering from within the human body,” Science, vol. 134, pp. 1196-1202, 1961. [10] X. Chen et al. “A wireless capsule endoscope system with low-power controlling and processing ASIC,” IEEE Transation on Biomedical Circuits and Systems, Vol. 3, February 2009. [11] E. A. Johannessen, et al. “Biocompatibility of a lab-on-a-pill sensor in artificial gastrointestinal environments,” IEEE Trans. Biomed. Eng., vol. 53, pp. 2333, Nov. 2006. [12] P. Valdastri , A. Menciassi , A. Arena ,C. Caccamo and P. Dario “An implantable telemetry platform system for in vivo monitoring of physiological parameters,” IEEE Trans. Inform. Technol. Biomed., vol.8, pp. 271, Sep. 2004. [13]www.google.nl/patents/US6632175 [14]http://www.techmezine.com/top-10-news/electronic-pills-collecting-data-inside-the-body/ [15]http://www.innovationessence.com/smart-collecting-inside/ [16]http://www.inventor-strategies.com/new-electronic-inventions.html [17]http://muettech.com/news/electronic-pills-collecting-data-inside-the-body/ [18]https://en.wikipedia.org/wiki/Microelectronics [19]Veendrick, H.J.M. (2011). Bits on Chips. p. 253. ISBN 978-1-61627-947-9. https://openlibrary.org/works/OL15759799W/Bits_on_Chips/
  • 8. Electronic Pills 8 CHAPTER NO#2 2.1 Components: The design of the microelectronic pill is in the form of a capsule. The encasing it has is biocompatible. Inside this are multi- channel (four channel) sensors and a control chip. It also comprises of a radio transmitter and two silver oxide cells. The four sensors are mounted on the two silicon chips. In addition to it, there are a control chip, one access channel and a radio transmitter. The four sensors commonly used are a temperature sensor, pH ISFET sensor, a dual electrode conductivity sensor and a three electrode electrochemical oxygen sensor. Among these the temperature sensor, the pH ISFET sensor and the dual electrode conductivity sensor are fabricated on the first chip. The three electrode electrochemical cell oxygen sensor will be on chip 2. The second chip also consists of a NiCr resistance thermometer which is optional. The basic Components of Electronic Pills are:  Sensors  Control Chip  Radio Transmitters  Silver Oxide Batteries Fig 1 block diagram *(1) access channel, (2) 4 sensors which are mounted on two silicon chips (Chip 1 & 2), *(3) capsule,* (4) Rubber ring, * (5) a control chip *(6) PCB chip carrier * (7) (9)(10) a radio transmitter (STD- type, type2-crystal)* (8) silver oxide batteries
  • 9. Electronic Pills 9 2.2 Description of Components 1) Sensors Figure 2: Sensors There are basically 4 sensors mounted on two chips- Chip 1 & chip 2. On chip 1(shown in fig 2 a), c), e)), temperature sensor silicon diode (4), pH ISFET sensor (1) and dual electrode conductivity sensor (3) are fabricated. Chip 2 comprises of three electrode electrochemical cell oxygen sensor (2) and optional NiCr resistance thermometer.
  • 10. Electronic Pills 10 a) Sensorchip1 An array consisting of both temperature sensor & pH sensor platforms were cut from the wafer and attached onto 100-µm- thick glass cover slip cured on a hot plate. The plate acts as a temporary carrier to assist handling of the device during level 1 of lithography when the electric connection tracks, electrode bonding pads are defined. Bonding pads provide electrical contact to the external electronic circuit. Lithography was the first fundamentally new printing technology since the invention of relief printing in the fifteenth century. It is a mechanical Plano graphic process in which the printing and non-printing areas of the plate are all at the same level, as opposed to intaglio and relief processes in which the design is cut into the printing block. Lithography is based on the chemical repellence of oil and water. Designs are drawn or painted with greasy ink or crayons on specially prepared limestone. The stone is moistened with water, which the stone accepts in areas not covered by the crayon. Oily ink, applied with a roller, adheres only to the drawing and is repelled by the wet parts of the stone. Pressing paper against the inked drawing then makes the print. Lithography was invented by Alois Senefelder in Germany in 1798 and, within twenty years, appeared in England and the United States. Almost immediately, attempts were made to print pictures in color. Multiple stones were used; one for each color, and the print went through the press as many times as there were stones. The problem for the printers was keeping the image in register, making sure that the print would be lined up exactly each time it went through the press so that each color would be in the correct position and the overlaying colors would merge correctly. Early colored lithographs used one or two colors to tint the entire plate and create a water color-like tone to the image. This atmospheric effect was primarily used for landscape or topographical illustrations. For more detailed coloration, artists continued to rely on hand coloring over the lithograph. Once tinted lithographs were well established, it was only a small step to extend the range of color by the use of multiple tint blocks printed in succession. Generally, these early chromolithographs were simple prints with flat areas of color, printed side-by-side. Increasingly ornate designs and dozens of bright, often gaudy, colors characterized chromolithography in the second half of the nineteenth century. Overprinting and the use of silver and gold inks widened the range of color and design. Still a relatively expensive process, chromolithography was used for large-scale folio works and illuminated gift books that often attempted to reproduce the handwork of manuscripts of the Middle Ages. The steam-driven printing press and the wider availability of inexpensive paper stock lowered production costs and made chromolithography more affordable. By the 1880s, the process was widely used for magazines and advertising. At the same time, however, photographic processes were being developed that would replace lithography by the beginning of the twentieth century. Chip 1 is divided into two- LHS unit having the temperature sensor silicon diode, while RHS unit comprises the pH ISFET sensor. DT-670-SD Silicon Diode Features
  • 11. Electronic Pills 11 Figure 3: DT-670-SD  It measures the body core temperature.  Also compensates with the temperature induced signal changes in other sensors.  It also identifies local changes associated with tissue inflammation & ulcers. ISFET Figure 4: ISFET Ion Selective Field Effect Transistor ISFET; this type of electrode contains a transistor coated with a chemically sensitive material to measure pH in solution and moist surfaces. As the potential at the chemically active surface changes with the pH, the current induced through the transistor varies. A temperature diode simultaneously monitors the temperature at the sensing surface. The pH meter to a temperature compensated pH reading correlates the change in current and temperature. This device has an affinity for hydrogen ions, which is the basis for the determination of the pH. The surface of the sensitive area of the sensor contains hydroxyl groups that are bound to an oxide layer. At low pH values hydrogen ions in the sample will bind to these hydroxyl groups resulting in a positively charged surface. In alkaline environments hydrogen ions are abstracted from the hydroxyl groups, leading to a negatively charged surface. Thus, each pH change has a certain influence on the surface charge. On its turn, this attracts or repulses the electrons flowing between two electrodes in the semiconductor device. The electronics compensates the voltage in order to keep the current between the two electrodes at its set point. In this way this potential change is related to the pH. Attachment of a polymer membrane on the ISFET introduces the possibility to go beyond the measurement of pH toward other ions. In this plastic layer certain chemicals (ionophores), which can recognize and bind the desired ion, are put in. Now, complex formations of the ionophore
  • 12. Electronic Pills 12 and the ion introduce a charge. The potential change is a measure for the ion concentration. Typically, these sensors can be used in a concentration range between app. 10.5 up to 1 mol/l. b) Sensor Chip 2: The level 1pattern (electric tracks, bonding pads, and electrodes) was defined in 0.9µm UV3 resist (Shipley, U.K.) by electron beam lithography. A layer of200 nm gold (including an adhesion layer of 15 nm titanium and 15 nm palladium) was deposited by thermal evaporation. The fabrication process was repeated (Level 2) to define the5- m-wide and 11-mm-long NiCr resistance thermometer made from a 100-nm-thick layer of NiCr (30- resistance).Level 3 defined the 500-nm-thick layer of thermal evaporated silver used to fabricate the reference electrode. An additional sacrificial layer of titanium (20 nm) protected the silver from oxidation in subsequent fabrication levels. The surface area Fig. 2. Photograph of the 4:75 2 4:75 mm application specific integrated circuit control chip (a),the associated explanatory diagram (b), and a schematic of the reference electrode was 1.5*10^-2 mm , whereas the of the architecture (c) illustrating the interface to external components. MUX counter electrode made of gold had an area of mm .(four-channel multiplexer), ADC, DAC , and OSC (32-kHz oscillator).Level 4 defined the microelectrode array of the working electrode, comprising 57 circular gold electrodes, each 10µm in diameter, with an inter electrode spacing of 25 m and a combined area of 4.5*10^-3 mm . Such an array promotes electrode polarization and reduces response time by enhancing transport to the electrode surface [26]. The whole wafer was covered with500 nm plasma-enhanced chemical vapour deposited (PECVD) Si3Ni4The pads, counter, reference,and the microelectrode array of the working electrode was exposed using an etching mask of S1818 photo resist prior to dry etching with C2F6 . The chips were then diced from the wafer and attached to separate100- m-thick cover slips by epoxy resin to assist handling. The electrolyte chamber was defined in 50- m-thick polyimide at Level 5. Residual polyimide was removed in an barrel a shear(2 min), prior to removal of the sacrificial titanium layer at Level6 in a diluted HF solution (HF to RO water, 1:26) for 15 s. The short exposure to HF prevented damage to the PECVD layer. Thermally evaporated silver was oxidized to Ag AgCl (50%of film thickness) by chronopotentiometry (120 nA, 300 s) at Level 7 in the presence of KCl, prior to injection of the internal reference electrolyte at Level 8. 2) Control Chip The ASIC (Application Specific Integrated Circuit) is the control unit that connects together other components of the micro system. It contains an analogue signal –conditioning module operating the sensors, 10-bit analogue to digital (ADC) & digital to analogue (DAC) converters,& digital data processing module. The temperature circuitry bias the diode at constant current so that change in temperature reflects a corresponding change in in diode voltage. The pH ISFET sensor is biased as a simple source at constant current with the source voltage changing with threshold voltage & pH. The ASIC was a control unit that connected together the external components of the micro system It was fabricated as a 22.5 mm silicon die using a 3-V, 2-poly, 3-metal 0.6µM The conductivity circuit operates at D.C. It measures the resistance across the electrode pair as an inverse function of solution conductivity. An incorporated potentiostat circuit operates the O2 sensor with a 10 bit DAC controlling the working electrode potential w.r.t the reference. Analogue signals are sequenced through a multiplexer before
  • 13. Electronic Pills 13 being digitized by ADC.ASIC & sensors consume 5.3 mW power corresponding to 1.7 mA of current. Fig.5 , the associated explanatory diagram of4:75 2 4:75 mm application specific integrated circuit control chip Fig 6 a schematic ofthe architecture Fig. 7.illustrating the interface to external Components. Is particularly effective when the measuring environment is acquiescent, a condition encountered in many applications The entire design was constructed with a focus on low power consumption and immunity from noise interference. The digital module was deliberately clocked at 32 kHz and employed a sleep mode to conserve power from the analogue module. Separate on-chip power supply trees and pad- ring segments were used for the analogue and digital electronics sections in order to discourage noise propagation and interference.
  • 14. Electronic Pills 14 3) Radio Transmitter The radio transmitter was assembled prior to integration in the capsule using discrete surface mount components on a single-sided printed circuit board (PCB). The footprint of the standard transmitter measured 8*5*3mm including the integrated coil (magnetic) antenna. It was designed to operate at a trans-mission frequency of 40.01 MHz at 20 C generating a signal of 10 kHz bandwidth. A second crystal stabilized transmitter was also used. This second unit was similar to the free running standard transmitter, apart from having a larger footprint of 10*5*3mm, and a transmission frequency limited to 20.08MHz at 20 C, due to the crystal used. Pills incorporating the standard transmitter were denoted Type I, whereas the pills in-cooperating the crystal stabilized unit were denoted Type II. The transmission range was measured as being 1 meter and the modulation scheme frequency shift keying (FSK), with a data rate of1Kbs^-1 4) Capsule The microelectronic pill consisted of a machined biocompatible (noncytotoxic), chemically resistant polyetherterket one (PEEK) capsule (Victrex, U.K.) and a PCB chip carrier acting as a common platform for attachment of the sensors, ASIC, transmitter and the batteries (Fig. 3). The fabricated sensors were each attached by wire bonding to a custom made chip carrier made from a 10-pin, 0.5-mm pitch polyimide ribbon connector. The ribbon connector was, in turn, connected to an industrial standard 10-pin flat cable plug (FCP) socket (Radio Spares, U.K.) attached to the PCB chip carrier of the microelectronic pill, to facilitate rapid replacement of the sensors when required. The PCB chip carrier was made from two standard1.6-mm-thick fiber glass boards attached back to back by epoxy resin which maximized the distance between the two sensor chips. The sensor chips were connected to both sides of the PCB by separate FCP sockets, with sensor Chip 1 facing the top face, with Chip 2 facing down. Thus, the oxygen sensor on Chip 2 had to be connected to the top face by three 200- m copper leads soldered on to the board. The transmitter was integrated in the PCB which also incorporated the power supply rails, the connection points to the sensors, as well as the transmitter and the ASIC and the supporting slots for the capsule in which the chip carrier was located. The ASIC was attached with double-sided copper conducting tape (Agar Scientific, U.K.) prior to wire bonding to the power supply rails, the sensor inputs, and the transmitter (a process which entailed the connection of 64 bonding pads). The unit was powered by two standard 1.55-V SR44 silver oxide cells with a capacity of 175 mAh. The batteries were serial connected and attached to a custom made 3-pin, 1.27-mm pitch plug well as making it easy to maintain (e.g., during sensor and battery replacement). The complete prototype was 16.55 mm and weighted 13.5 g including the batteries. A smaller pill suitable for physiological in vivo trials (10 30 mm) is currently being developed from the prototype.
  • 15. Electronic Pills 15 CHAPTER NO#3 3.1 WORKING 1) GeneralSetup All the devices were powered by batteries in order to demonstrate the concept of utilizing the microelectronic pill in remote locations (extending the range of applications from in vivo sensing to environmental or industrial monitoring). The pill was submerged in a 250-mL glass bottle located within a 2000-mLbeaker to allow for a rapid change of pH and temperature of the solution. A scanning receiver (Winradio Communications, Australia) captured the wireless radio transmitted signal from the microelectronic pill by using a coil antenna wrapped around the 2000-polypropylene beaker in which the pill was located. A portable Pentium III computer controlled the data acquisition unit (National Instruments, Austin, TX) which digitally acquired analogue data from the scanning receiver prior to recording it on the computer. The solution volume used in all experiments was 250 mL The beaker,pill, glass bottle, and antenna were located within 25*25 cm container of polystyrene, reducing temperature fluctuations from the ambient environment (as might be expected within the GI tract) and as required to maintain a stable transmission frequency. The data was acquired using Lab View (National Instruments, Austin, TX) and processed using a MATLAB (Math works, Natick, MA) routine. 2) Sensing The lifetime of the incorporated AgCl reference electrodes used in the pH and oxygen sensors was measured with an applied current of 1 pA immersed in a 1.0 M KCl electrolyte solution. The current reflects the bias input current of the operational amplifier in the analogue sensor control circuitry to which the electrodes were connected The temperature sensor was calibrated with the pill submerged in reverse osmosis (RO) water at different temperatures. The average temperature distribution over 10 min was recorded for each measurement,represented as 9.1 C, 21.2 C, 33.5C, and 47.9 C The system was allowed to temperature equilibrate for 5 min prior to data acquisition. The control readings were performed with a thin wire K-type thermocouple(Radio Spares, U.K.). The signal from the temperature sensor as investigated with respect to supply voltage potential, due to the temperature circuitry being referenced to the negative supply rail. Temperature compensated readings (normalized to23 C) were recorded at a supply voltage potential of 3.123,3.094, 3.071, and 2.983 mV using a direct communication link. Bench testing of the temperature sensor from 0 C to 70 C was also performed to investigate the linear response characteristics of the temperature sensor. The pH sensor of the microelectronic pill was calibrated in standard pH buffers [28] of pH 2, 4, 7, 9, and 13, which reflected the dynamic range of the sensor. The calibration was performed at room temperature (23 C) over a period of 10 min, with the CMOS process by Austria Microsystems (AMS) via the Euro practice initiative It is a novel mixed signal design that contains an analogue signal conditioning module operating the sensors,an
  • 16. Electronic Pills 16 10-bit analogue-to-digital (ADC) and digital-to-analogue(DAC) converters, and a digital data processing module. An RC relaxation oscillator (OSC) provides the clock signal. The analogue module was based on the AMS OP05B operational amplifier, which offered a combination of both a power having scheme (sleep mode) and a compact integrated circuit design. The digital data processing module conditioned the digitized signals through the use of a serial bit stream data compression algorithm, which decided when transmission was required by comparing the most recent sample with the previous sampled data. This technique minimizes the transmission length, and comprising the electronic pill. The prototype is 16 2 55 mm, weights 13.5 g.The Type I unit consist of the microelectronic sensors at the front enclosed by the metal clamp and rubber seal(1) which provide a 3-mm-diameter access channelto the sensors (2). The front section of the capsule, physically machined from solid PEEK,is illustrated (3) with the rear section removed to illustrate the internal design. The front and rear section of the capsule is joined by a screw connection sealed of by a Viton-rubber o-ring (4). The reduction potential of water was assessed in oxygen depleted PBS,to avoid interference from oxygen, at the same time assessing the lower potential limit that could be used for maximizing the efficiency of the sensor. The voltage was then fixed above this reduction potential to assess the dynamic behavior of the sensor upon injection of saturated in oxygen saturated PBS. 3) Oxygen detection by Sensor. Most portable or survey instruments used for workplace evaluation of oxygen concentrations make use of "fuel cell" type oxygen sensors. "Fuel cell" oxygen sensors consist of a diffusionbarrier,asensingelectrode (cathode) made of anoble metal suchasgold or platinum, and a workingelectrode made of abase metal suchas leador zincimmersedinabasic electrolyte(suchasa solution of potassium hydroxide). Oxygen diffusing into the sensor is reduced to hydroxyl ions at the cathode: O2 + 2H2O + 4e- OH – Hydroxyl ions in turn oxidize the lead (or zinc) anode: 2Pb + 4OH 2PbO + 2H2O + 4e – This yields an overall cell reaction of: 2Pb + O2 2PbO Fuel cell oxygen sensors are current generators. The amount of current generated is proportional to the amount of oxygen consumed (Faraday's Law). Oxygen reading instruments simply monitor the current output of the sensor. An important consideration is that fuel cell oxygen sensors are used up over time. In the cell reaction above, when all available surface area of the lead (Pb) anode has been converted to lead oxide (PbO), electrochemical activity ceases, current output falls to zero, and the sensor must be rebuilt or replaced. Fuel cell sensors are designed to last no more than one to two years. Even when
  • 17. Electronic Pills 17 installed in an instrument which is never turned on, oxygen sensors which are exposed to atmosphere which contains oxygen are generating current, and being used up. Oxygen sensors are also influenced by the temperature of the atmosphere they are being used to measure. The warmer the atmosphere, the faster the electrochemical reaction. For this reason oxygen sensors usually include a temperature compensating load resistor to hold current output steady in the case of fluctuating temperature. (Microprocessor based instrument designs usually provide additional signal correction in software to further improve accuracy.) Another limiting factor is cold. The freezing temperature of electrolyte mixtures commonly used in oxygen sensors tends to be about 5o F (-20o C). Once the electrolyte has frozen solid, electrical output falls to zero, and readings may no longer be obtained. There are two basic variations on the fuel cell oxygen sensor design. These variations have to do with the mechanism by which oxygen is allowed to diffuse into the sensor. Dalton's Law states that the total pressure exerted by a mixture of gases is equal to the sum of the partial pressures of the various gases. Figure 8: Capillary pore type oxygen sensor Effects of contaminants on oxygen sensors Oxygen sensors may be affected by prolonged exposure to "acid" gases such as carbon dioxide. Most oxygen sensors are not recommended for continuous use in atmospheres which contain more than 25% CO 2. Substance-specific electrochemical sensors One of the most useful detection techniques for toxic contaminants is the use of substance-specific electrochemical sensors installed in compact, field portable survey instruments. Substance-specific electrochemical sensors consist of a diffusion barrier which is porous to gas but nonporous to liquid, reservoir of acid electrolyte (usually sulphuric or phosphoric acid), sensing electrode, counter electrode, and (in three electrode designs) a third reference electrode. Gas diffusing into the sensor reacts at the surface of the sensing electrode. The sensing electrode is made to catalyze a specific reaction. Dependent on the sensor and the gas being measured, gas diffusing into the sensor is either oxidized or reduced at the surface of the sensing electrode. This reaction causes the potential of the
  • 18. Electronic Pills 18 sensing electrode to rise or fall with respect to the counter electrode. The current generated is proportional to the amount of reactant gas present. This two electrode detection principle presupposes that the potential of the counter electrode remains constant. In reality, the surface reactions at each electrode causes them to polarize, and significantly limits the concentrations of reactant gas they can be used to measure. In three electrode designs it is the difference between the sensing and reference electrode which is what is actually measured. Since the reference electrode is shielded from any reaction, it maintains a constant potential which provides a true point of comparison. With this arrangement the change in potential of the sensing electrode is due solely to the concentration of the reactant gas. Figure 9: Three electrode electrochemical sensor 4) Transmission The pill’s transmission frequency was measured with respect to changes in temperature. The Type I pill (without crystal) was submerged in RO water at temperatures of 1 C, 11 C, 23 C,and 49 C, whereas the Type II pill (with crystal) was submerged in temperatures of 2 C, 25 C, and 45 C. The change in frequency was measured with the scanning receiver, and the results used to assess the advantage of crystals stabilized units at the cost of a larger physical size of the transmitter.  Dynamic Measurements Dynamic pH measurements were performed with the pill submerged in a PBS solution at 23 C. The pH was changed from the initial value of 7.3 by the titration of 0.1 M Hand0.1 MNaOH,respectively. Subsequently, the pH was changed from pH 7.3 to pH 5.5 (after 5 min), pH 3.4 (after 8 min) top 9.9 (after 14 min) and back to pH 7.7 (after 21 min). A standard (bench-top) pH electrode monitored the pH of the solution. The solutions were sampled after the pH change, and measured outside the experimental system to prevent electronic noise injection from the pH electrode. The temperature channel was recorded
  • 19. Electronic Pills 19 simultaneously. 5) Sensorand Signal Drift Long term static pH and temperature measurements were performed to assess signal drift and sensor lifetime in physiological electrolyte (0.9% saline) solutions. A temperature of 36.5 Cwas achieved using a water bath, with the assay solutions continuously stirred and re-circulated using a peristaltic pump. The sensors were transferred from solutions of pH 4 to pH 7, within2 h of commencing the experiment, and from pH 7 to pH 10.5. Fig. 10.pH sensor: (a) pH recording in the range ofpH 2 to 13, represented by digital data points; (b) dynamic recording oftemperature (1) and pH (2) using a direct communication link illustrates the temperature sensitivity ofthe pH channel.
  • 20. Electronic Pills 20 Fig. 11 Temperature sensor: (a) temperature recording over a range from 9.1 C to 47.9 C, represented by digital data points; (b) high-resolution plot ofa temperature change from 49.8 C to 48.7 C. The control measurement from the thermocouples is presented as solid points with error bars representing the resolution of the thermometer. The resolution of the temperature channel was noise limited to 0.4 C(16:8 mV C),whereas the temperature channel is insensitive to any pH is chanced use the temperature channel to drift. Thus, bench test measurements conducted on the temperature sensor revealed that the output signal changed by 1.45 mV per mV change in supply voltage ( (mV)-1.4Mv expressed in mill volts, corresponding to a drift of -21mVin the pill from a supply voltage change of- 14.5Mv
  • 21. Electronic Pills 21 6) RESULTS The power consumption of the microelectronic pill with the transmitter, ASIC and the sensors connected was calculated to12.1 mW, corresponding to the measured current consumption of 3.9 mA at 3.1-V supply voltage. The ASIC and sensors consumed 5.3 mW, corresponding to 1.7 mA of current, whereas the free running radio transmitter (Type I) consumed 6.8 mW(-corresponding to 2.2 mA of current) with the crystal stabilized unit (Type II) consuming 2.1 mA. Two SR44bat-teries used provided an operating time of more than 40 h for the micro system. 7) DISCUSSION Capsules as Actuators Drug delivery system is an issue of optimization for many interests, immediate release drug will be absorbed in the upper part of the small intestine after stomach, extended release drug is desired to be absorbed in the lower level of the intestine. Achievement of the second by normal coating tablets is difficult due to the complexity of the GI tract of human being, intubations is an alternative solution, but it is uncomfortable for patients. Alternative solution will be of more interest, and the idea of developing swallowed capsules devices was , over two decades engineers are trying to develop different capsules with the capability to control the time and the location of the drug release. The earlier capsules in this domain were HF,Indelicate, and Telemetric Capsules. They are triggered by a radio frequency (RF) pulse from a generator outside body, the heat generated in the circuit will melt a thread releasing a needle that pierces the container and spells out the drug. State-of-the-art in this domain are the Enterion™ capsule and ChipRxThe patient must undergo several gamma scans to identify the location. Telemetric capsule uses a cogwheel means for localization. Enhancement in localization is of more interest and more work can be done in this domain to achieve a practical solution for position determination Capsules as Sensors Monitoring the variation of temperature, pH, motility and other functions are getting easier and comfortable for patients. The need to collect biomedical information within a specific location is of high interest, most of the existing sensor capsules don’t provide location determination. Earlier products in this field are the Radio Pill, BRAVO, Heidelberg and Temperature capsules. Almost all of them use internal battery for power consumption. New capsules in this field are A newplatform of an electronic pill with bidirectional communication system for miniaturized and low power biomedical applications