SlideShare ist ein Scribd-Unternehmen logo
1 von 32
Downloaden Sie, um offline zu lesen
Hazardous Interim Cover.FH11 Sat Feb 07 11:04:56 2009 Page 2
Composite
C M Y CM MY CY CMY K
Engineering Solutions
Design to Manufacture
An A-Belco Group Company
L I G H T I N GF O R H A Z A R D O U S A R E A S
CABLE JOINTS, CABLE TERMINATIONS, CABLE GLANDS, CABLE CLEATS
FEEDER PILLARS, FUSE LINKS, ARC FLASH, CABLE ROLLERS, CUT-OUTS
11KV 33KV CABLE JOINTS & CABLE TERMINATIONS
FURSE EARTHING
www.cablejoints.co.uk
Thorne and Derrick UK
Tel 0044 191 490 1547 Fax 0044 191 477 5371
Tel 0044 117 977 4647 Fax 0044 117 9775582
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 1
Composite
C M Y CM MY CY CMY K
The Hadar Lighting Range
Designed and manufactured in the UK by A-Belco Hazardous
Area, the portfolio of products comprises:
Fluorescent
Recessed
Portable
Bulkhead
Wellglass
Floodlight
LED
Suitable for use in any environment where an explosive atmosphere
may exist, the range of luminaires within the Hadar Lighting portfolio
are certified to Zone 1, Ex e, Ex d, and Zone 2 Ex n.
Launched in 2005, a high degree of engineering expertise, project
knowledge, experience and investment in the Hadar Lighting range
is reflected through the high specification construction of the
luminaires.
The innovative, modular and low maintenance designs incorporate
the latest technologies, ensuring a comprehensive lighting product
offering. The Ex e products feature the "End of Life" (EoL) protection
circuit ballast according to DIN EN 61347-2-3 and IEC 60079-7
Ed.4.
Working alongside our network of UK and global distributors and
partners in Australia, Singapore and Malaysia, USA and UAE, we
offer competitive export bid packages for a wide range of projects.
From design to manufacture, we excel in quality, price, delivery
and after sales support.
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 2
Composite
C M Y CM MY CY CMY K
LIGHTING RANGE
Zone 1
HDL 100 Fluorescent 2
HDL 102 Recessed 4
HDL 103G Helideck Luminaire 6
HDL 103R Obstruction Luminaire 6
HDL 103W Bulkhead Luminaire 6
HDL 105 Portable 8
HDL 105T Transformer 10
CTB Junction Box 11
HDL 106 LED Floodlight 12
HDL 108 Bulkhead (metal) 14
HDL 109 Bulkhead (plastic) 16
HDL 113 Small Wellglass 18
HDL 114 Large Wellglass 18
HDL 133 Small QL Wellglass 18
HDL 134 Large QL Wellglass 18
HDL 117 Floodlight 20
Zone 2
HDL 220 Fluorescent 22
HDL 223 Small Wellglass 24
HDL 224 Large Wellglass 24
HDL 233 Small QL Wellglass 24
HDL 234 Large QL Wellglass 24
HDL 227 Floodlight 26
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 3
Composite
C M Y CM MY CY CMY K
Simple installation.
Straightforward maintenance.
Pole mount option.
Emergency version available.
Rugged construction.
Easily relamped with detachable lamp envelope.
Mains isolation not required when relamping.
Short gaskets for proven ingress protection.
Mounting in any attitude.
Features a reflector compatible with Unistrut channel support systems
and accessories.
Pole Mount available.
Continuous monitoring of fluorescent lamps ensures safe end of life
shutdown by electronic ballast in accordance with HSE safety notice 8/05.
Overvoltage protection 320V for 1 minute.
Electronic control gear for instant operation and reduced running costs.
High frequency electronic ballast suitable for operation at lower temperatures.
EMERGENCY VERSION
Standard emergency - one fluorescent lamp
remains at a reduced output.
Can be operated maintained or non maintained.
HADAR LIGHTING
Zone 1 Ex em FLUORESCENT LUMINAIRE - HDL 100
KEY FEATURES - Zone 1 Ex em Fluorescent Luminaire
2
SPECIFICATION
Enclosure Polycarbonate
Lamp Envelope Polycarbonate
Reflector Aluminium Powder Coated
Gaskets Silicone
External Fasteners A4 Stainless Steel
T Rating T4/T5 Gas and Dust
Surface Temp 100ºC
2 x 18W / 36W -30ºC to +55ºC T4
-30ºC to +32ºC T5
2 x 58W -30ºC to +53ºC T4
Emergency Range -15ºC
DIMENSIONS
PROTECTION II 2GD Ex emb II T4/T5 IP66/67
Ex tD A21 T100ºC
Incorporates the new “End of Life” (EoL) protection circuit ballast -
according to DIN EN 61347-2-3 and IEC 60079-7 Ed.4 Annex H
CERTIFICATION ATEX & IEC Ex CERTIFIED BY SIRA; ABS APPROVED FOR MARINE USE
Certification Ambient Certificate
HDL 100 II 2GD Ex emb II T4/T5 IP66/67 IEC Ex SIR 06.0026X
SIRA 06 ATEX 3079X
ABS 07-LD219463-PDA
Voltage Range
110V to 254V
2 x 18W
2 X 36W
2 X 58W
970mm
1580mm
1880mm
A Weight
4kg
5.8kg
6.8kg
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 4
Composite
C M Y CM MY CY CMY K
3
2 x 18W 32W circuit watts at 240V - 0.14A (120V - 0.28A) Better 220V - 254V, 47/63 Hz AC/DC
2 x 36W 62W circuit watts at 240V - 0.27A (120V - 0.54A) Than 110V - 130V, 47/63 Hz AC/DC (2 x 18W/2 x 36W only)
2 x 58W 92W circuit watts at 240V - 0.40A (120V - 0.80A) 0.95 Emergency version as above - AC only
ELECTRICAL SPECIFICATIONS
Lamp Options
Power consumption Power factor Power supply
Electrical Specification
HADAR LIGHTING
Zone 1 Ex em FLUORESCENT LUMINAIRE - HDL 100
Product HDL100
S - Non Emergency
E - Emergency
L - Loop In / Loop Out
P - Pole Mount
H - High Voltage (220V - 254V)
M - Medium Voltage (110V - 130V)
0 - M20 entries
5 - M25 entries
218 - 2 x 18W
Lamp Options 236 - 2 x 36W
258 - 2 x 58W
ORDERING MATRIX
Field Options
Fittings
Voltage
Cable Entries
Up to 6mm2 clamp terminals for live, live switched, neutral, earth and looping are provided. Internal and external earth as standard.
Screw terminals upon request.
Installation document AL10086 supplied.
2 x M20. Pole mount fittings supplied with 1 x M20 (other entries upon request).
INSTALLATION
Terminals
Cable Entries
The aluminium reflector incorporates a channel which is compatible with Unistrut (or equivalent) fixings and accessories and allows
the installer to select variable fixing centres. Technical Booklet with various mounting options available upon request.
Suspension
Installation
1) Final Product Code should be in the format: HDL100SPH0218
2) Bi-Pin as standard. Contact sales office for Single Pin.
3) For Photometric Data contact the sales office.
4) Brass earth continuity gland plates are available, contact sales office for more
information.
Notes
Version
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 5
Composite
C M Y CM MY CY CMY K
DIMENSIONS FOR NON MODULAR
RANGE OF RECESSIBLES
FOR MODULAR RANGE
DIMENSIONS CONTACT THE
SALES DEPT
Exposed ‘T’/Concealed ‘T’ Modular ceiling type.
Plasterboard Non-modular Ceiling type.
Plank Ceiling type 300mm wide.
Mild Steel painted as standard (Stainless steel also available).
2 x 18 W, 4 x 18W, 2 x 36W, 4 x 36W, 2 x 58W.
Emergency version available.
For 2 x 18W Compact Fluorescent Luminaire see - HDL 108.
Ease of maintenance and installation.
Wide range of lamp options.
High frequency electronic control gear.
Quick lamp start and flicker free operation control gear.
High ambient areas.
Can be installed in new or existing ceilings.
Lightweight and robust construction.
Cable entries can be positioned to suit customer requirements.
Overvoltage protection 320V for 1 minute.
Standard/Emergency gear trays interchangeable between luminaires.
Continuous monitoring of fluorescent lamps ensures safe end of life shutdown.
by electronic ballast in accordance with HSE safety notice 8/05.
Optional mains isolation/battery isolation microswitch available.
EMERGENCY VERSION
Emergency version as above - AC only.
HADAR LIGHTING
Zone 1 Ex em RECESSED LUMINAIRE - HDL 102
KEY FEATURES - Zone 1 Ex em Recessed Luminaire
4
SPECIFICATION
Enclosure Steel Powder Coated
Diffuser Frame or Stainless Steel
Diffuser Toughened Prismatic Glass
Gasket Silicone
External Fasteners A4 Stainless Steel
T Rating T4/T5 Gas and Dust
Surface Temp 75ºC
All ranges T4 -40ºC to +55ºC
All ranges T5 -40ºC to +40ºC
Emergency Range -15ºC
DIMENSIONS
PROTECTION II 2GD Ex emb II T4/T5 IP64
Ex tD A21 T75ºC
CERTIFICATION ATEX & IEC Ex CERTIFIED BY SIRA
Certification Ambient Certificate
HDL 102 II 2GD Ex emb II T4/T5 IP64 IEC Ex SIR 06.0027
SIRA 06 ATEX 3080
Voltage Range
110V - 254V
2 x 18W
2 x 36W
2 x 58W
4 x 18W
4 x 36W
A Weight
Incorporates the new “End of Life” (EoL) protection circuit ballast - according to
DIN EN 61347-2-3 and IEC 60079-7 Ed 4 Annex H
B
10kg
16kg
18kg
15kg
18kg
700mm
1310mm
1610mm
700mm
1310mm
299mm
299mm
299mm
599mm
599mm
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 6
Composite
C M Y CM MY CY CMY K
1) Final Product Code should be in the format: HDL102SCH0218
2) Bi-Pin as standard. Contact sales office for single pin.
3) Mild Steel as standard, contact sales office for stainless steel.
4) For Photometric data contact the sales office.
5
2 x 18W T8 32W circuit watts at 240V - 0.14A (120V - 0.28A)
2 x 36W T8 62W circuit watts at 240V - 0.27A (120V - 0.28A) Better 220V - 254V, 47/63 Hz AC/DC
2 x 58W T8 92W circuit watts at 240V - 0.40A (120V - 0.80A) Than 110V - 130V, 47/63 Hz AC/DC (18W/36W only)
4 x 18W T8 64W circuit watts at 240V - 0.28A (120V - 0.56A) 0.95 Emergency version as above - AC only
4 x 36W T8 124W circuit watts at 240V - 0.54A (120V - 1.08A)
ELECTRICAL SPECIFICATIONS
Lamp Options
Power consumption Power factor Power supply
Electrical Specification
HADAR LIGHTING
Zone 1 Ex em RECESSED LUMINAIRE - HDL 102
HDL102
S - Non Emergency
E - Emergency
A - Exposed ‘T’
B - Concealed ‘T’
C - Non Modular
D - Plank
H - High Voltage (220V - 254V)
M - Medium Voltage (110V - 130V)
0 - M20 Entries
5 - M25 Entries
218 - 2 x 18W
236 - 2 x 36W
258 - 2 x 58W
418 - 4 x 18W
436 - 4 x 36W
ORDERING MATRIX
Field Options
Fittings
Voltage
Cable Entries
Up to 6mm2 clamp terminals for live, live switched, neutral, earth and looping are provided. Internal and external earth as standard.
Screw terminals upon request.
Installation document AL10089 supplied.
To suit individual customer requirements.
INSTALLATION
Terminals
Cable Entries
To suit individual customer requirements.Suspension
Installation
Notes
Product
Version
Lamp Options
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 7
Composite
C M Y CM MY CY CMY K
HADAR LIGHTING
Zone 1 LED HELIDECK/OBSTRUCTION/BULKHEAD LUMINAIRE - HDL 103
6
Available in Green (Helidecks), Red (Obstruction) or White (general lighting).
Customer can select constant light output or flashing upon installation.
Conforms to ICAO annex 14 volume II and CAP437 for helideck perimeter lighting.
LED technology will give a predicted working life of 10 years +.
Utilises 6 off 1.2W LEDs.
Low power consumption.
Easy installation and low maintenance.
Rugged construction - resistant to vibration.
Instant light output.
360º coverage.
Independently photometrically tested.
All units supplied with 3 cable entries.
IP66 and IP67.
Optional wire guard available for extra protection.
KEY FEATURES - LED Helideck/Obstruction/Bulkhead Luminaire/Zone 1 Ex em
All variants -30ºC to +55ºC
DIMENSIONS
PROTECTION II 2GD Ex emb II T4/T5/T6 IP66/67, Ex tD A21 T100ºC
CERTIFICATION ATEX & IEC Ex PENDING BY SIRA
Certification Ambient Certificate
HDL103 II 2GD Ex emb II T4/T5/T6
IP66/67
ATEX and IEC Ex pending
Voltage Range
110V to 254V
SPECIFICATION
Main Body Marine Grade Aluminium
Clear Lens Polycarbonate
Gaskets Silicone/Rubber
External Fasteners A4 Stainless Steel
T Rating T4/T5/T6
Surface Temp 100ºC
Weight 3.0kg
124 CRS
124CRS
125
Ø200
4 FIXING
HOLES Ø11
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 8
Composite
C M Y CM MY CY CMY K
7
HADAR LIGHTING
Zone 1 LED HELIDECK/OBSTRUCTION/BULKHEAD LUMINAIRE - HDL 103
6 x 1.2W LED's
ELECTRICAL SPECIFICATIONS
Lamp Options
Power consumption Power factor Power supply
Electrical Specification
HDL103
G - Green LED's
R - Red LED's
W - White LED's
0 - No wire guard
1 - Wire guard fitted
0 - M20
5 - M25
00 - Standard
ORDERING MATRIX
Field Options
Up to 4mm 2 screwed terminals for live, neutral, earth and looping are provided. Internal and external earth as standard.
Installation document AL10319 supplied.
3 x M20, one fitted with approved stopper plug, other entries available on request.
INSTALLATION
Terminals
Cable Entries
Via 4 external mounting points.Suspension
Installation
1) Typical ordering reference HDL103G0000.
2) For Photometric Data contact the sales office.
Notes
Product
Version
Fittings
12W Max N/A 110V-254V 47/63Hz AC/DC
Cable Entries
Other Options
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 9
Composite
C M Y CM MY CY CMY K
2 x 18W, 2 x 36W, 2 x 58W, 4 x 18W, 4 x 36W and 4 x 58W Compact Fluorescent Lamp.
2 x 18W, 2 x 36W, 2 x 58W T8 Fluorescent Lamp, Bi Pin or Single Pin.
Wide Voltage range (24V to 254V).
Can be supplied with direct cable entries or fitted with plugs / sockets to allow luminaires
to be instantly linked in series (plug and play). Emergency versions available for T8 lamp
variant.
IP68 rated.
Aluminium or polycarbonate end caps.
Rugged construction.
Easily relamped - uses standard compact fluorescent lamp / T8 lamp.
Short gaskets for proven ingress protection.
Mounting in any attitude.
Features mounting points compatible with Unistrut support systems and accessories.
Can be supplied with pre-fitted cable, plug and mounted socket (eg. ATX, Stahl, Ceag).
Hanging / Carrying strap supplied as standard.
Continuous monitoring of fluorescent lamps ensures safe end of life shutdown by electronic
ballast in accordance with HSE safety notice 8/05 Overvoltage protection 320V for 1 minute
(110V and 240V only).
Electronic control gear for instant operation and reduced running costs.
High frequency electronic ballast suitable for operation at lower temperatures.
Portable versions are supplied with an anti static protective coating.
Industrial variant available.
Can be supplied with SY, HOFR or ships cable.
Available with a variety of accessories, mounting stands, tripods.
Replaceable, protective films available for use in paint shop applications.
KEY FEATURES - Zone 1 Ex em Portable Temporary Permanent Linkable Luminaire
EMERGENCY VERSION
Standard emergency - one fluorescent lamp remains
at a reduced output
Can be operated maintained or non maintained
(T8 110V or 240V ac variants only).
PROTECTION II 2GD Ex emb II T3/T4 IP66/67/68 (30 minutes at 3m depth)
EEx tD A21 T100ºC
SPECIFICATION
End caps Polycarbonate or Aluminium
Clear tube Polycarbonate
Gasket Silicone
External fasteners A4 Stainless steel
T Rating T3/T4 Gas and Dust
Surface Temperature 100ºC
Incorporates the new "End of Life" (EoL) protection circuit ballast -
according to DIN EN 61347-2-3 and IEC 60079-7 Ed.4 Annex H
CERTIFICATION ATEX & IEC Ex CERTIFIED BY SIRA
Certification Ambient Certificate
HDL105 Cable Gland option
II 2GD Ex emb II T3/T4 IP66/67/68
Plug and Socket option
II 2GD Ex embd IIC T3/T4 IP66
IEC Ex SIR 07.0020
SIRA 07 ATEX 3032
Voltage Range
4 x CFL -20ºC to +35ºC T3
2 x CFL -20ºC to +44ºC T3
2 x T8 -20ºC to +53ºC T4
Emergency Range -15ºC to +53ºC T4
24V - 28V AC/DC
42V - 54V AC/DC
110V - 130V AC/DC
220V - 254V AC/DC
8
Magnetic fixing brackets allow ease of installation / removal
to steel structures
Stand attachment allows vertical
orientation, ideal for maintenance
requirements
HADAR LIGHTING
Zone 1 Ex em PORTABLE TEMPORARY PERMANENT LINKABLE LUMINAIRE - HDL 105
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 10
Composite
C M Y CM MY CY CMY K
Up to 4mm2 screwed terminals for live, live switched, neutral, earth and looping are provided. Internal earth as standard.
Installation document AL10171.
Each aluminium or polycarbonate end cap incorporates 4 channels which are compatible with Unistrut (or equivalent) fixings and
accessories supplied with suitable suspension / carrying strap M6 clearance holes allow mounting plates to be attached to provide
free standing luminaires. Tri pod, floor stands and other various accessories are available.
INSTALLATION
Terminals
Suspension /
Mounting
Installation
2) For Photometric Data contact the sales office
3) Cable entries - over 5000 combinations (M20/M25 entries, plug, socket
and cable variants). Contact the technical department.
1) Typical ordering reference: HDL105SAL00218C
Notes
2 x 18W
2 x 36W
2 x 55/58W
4 x 18W
4 x 36W
4 x 55W
ELECTRICAL SPECIFICATIONS
Lamp Options
Typical power consumption Power factor Available power supplies
Electrical Specification
32W
62W
92W
64W
124W
184W
Better
than
0.95
220V - 254V 47/63 Hz AC/DC (all variants)
110V - 130V 47/63 Hz AC/DC (18W & 36W only)
24V - 28V AC/DC (36W only)
42V - 54V AC/DC (36W only)
HDL105
S - Standard
E - Emergency
A - Aluminium
P - Polycarbonate
H - High Voltage 220 - 254V
M - Medium Voltage 110V - 130V
L - Low Voltage 42V - 54V
E - Extra Low Voltage 24V - 28V
00 - Refer to Notes
218 - 2 x 18W
236 - 2 x 36W
258 - 2 x 55/58W
418 - 4 x 18W
436 - 4 x 36W
458 - 4 x 55W
C - Compact
B - Bi Pin T8
S - Single Pin T8
ORDERING MATRIX
Field 0ptions
Voltage
Cable Entries
Product
Version
Lamp Options
Lamp Type
9
HADAR LIGHTING
Zone 1 Ex em PORTABLE TEMPORARY - PERMANENT LINKABLE LUMINAIRE - HDL105
End Caps
DIMENSIONS
2 x 18W 399
2 x 36W 552
2 x 58W 676
4 x 18W 588
4 x 36W 782
4 x 58W 906
Lamp Typical length mm
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 11
Composite
C M Y CM MY CY CMY K
10
HADAR LIGHTING
Zone 1 Ex ed TRANSFORMER - HDL 105T
316L stainless steel enclosure and skid.
Feed through terminals.
Input and output fuse holder.
400VA, 110V or 230V input, 24V or 48V output.
Entry devices - 2 cable glands or input sockets / plugs.
Output devices - 2 to 4 cable glands or output sockets / plugs.
Comes mounted on a stainless steel skid.
Related Lighting Product: HDL 105 Ex em Portable.
KEY FEATURES - Ex ed Transformer
SPECIFICATION
Enclosure/Skid A4 Stainless Steel
Gasket One Piece Polyurethane
Operating Temperature
-80°C to 100°C
Door Fixings Hinged Removable Door with
Captive Fastening Screws
Earth Screws M10 Internal and External Brass Earth
Stud Assembly M6 Stud on the Door
DIMENSIONS
PROTECTION II 2GD Ex ed IIC T4 IP66
-20°C to +40°C
-20°C to +30°C
CERTIFICATION ATEX approved by SIRA
Certification Ambient Certificate
HDL 105T 350VA:
II 2GD Ex ed IIC T4
400VA:
II 2GD Ex ed IIC T4
SIRA 07 ATEX 3277X
Voltage Range
110V or 230V input
24V or 48V output
HDL105T
11V - 110V
23V - 230V
5 - 50Hz
6 - 60Hz
00 - 4 x 16A socket outlets
01 - 2 x 16A socket outlets
00 - 2 x M20 clearance holes
01 - 1 x M20 clearance holes
ORDERING MATRIX
Field Options
Frequency
Voltage
1) Final Product Code should be in one format:
HDL105T2350000.
2) For non-standard variations contact the sales office.
Notes
Product
Outlet Options
Inlet Options
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 12
Composite
C M Y CM MY CY CMY K
CSTB121208-SS
CSTB151509-SS
CSTB191910-SS
CTB221513
CTB262616
CTB262620
CTB303016
CTB303020
CTB382616
CTB382620
CTB453816
CTB453820
CTB484816
CTB484820
CTB503516
CTB503520
CTB624516
CTB624520
CTB745520
CTB765020
CTB866420
CTB916120
CTB987420
11
HADAR LIGHTING
Zone 1 EEx e CTB JUNCTION BOX
AISI 316L Stainless Steel.
Used as increased safety and / or intrinsic safety enclosures
in electrical systems. They can be supplied with or without
terminals; with multiple boxes, modular terminals and drilled
with holes according to customer specifications.
CSTB – small terminal box with no gland plate option.
Options include; Tag identification plates, Gland plates 1, 2,
3 and 4; Stopping plugs and Drain and breather valves.
KEY FEATURES - EEx e - CTB
-50°C to +40°C
-50°C to +55°C
-50°C to +55°C
-50°C to +40°C
-50°C to +55°C
-50°C to +55°C
-50°C to +40°C
-50°C to +55°C
-50°C to +55°C
-50°C to +40°C
-50°C to +55°C
-50°C to +55°C
CERTIFICATION ATEX approved by SIRA
Certification Ambient Certificate
Terminal Box SIRA 03 ATEX 3386
PROTECTION CE Ex II 2GD EEx e II EEx ia IIC T6/T5 IP66
Empty Box
EEx e II T6
EEx e II T6
EEx e II T5
EEx ai IIC T6
EEx ai IIC T6
EEx ai IIC T5
EEx e II T6
EEx e II T6
EEx e II T5
EEx ai IIC T6
EEx ai IIC T6
EEx ai IIC T5
SIRA 03 ATEX 3397U
SPECIFICATION
Material Highly corrosion resistant 1.5/2.0mm stainless steel 316L or mild
steel pregalvanised and painted RAL7015
1000 hours saltspray test
Surface treatment: ultrasonic degreased and passivated
Gasket One piece polyurethane gasket
Operating temperature -80°C to 100°C
Door Fixings Hinged removable door with captive fastening screws
Box Mounting 4 x external lugs, 11mm diameter holes
4 x direct fixing holes (M6) on rear of box (no lugs required)
Stud Assembly M6 Stud on the Door
Internal Mounting 4 x stand off 14mm dia. Pillars 25mm high tapped M6 for Din rail
or mounting plate installations
Earth Screws M10 internal and external brass earth stud assembly with an M6
stud on the door
Part Number
Size mm
L W H
120
150
190
229
260
260
300
306
380
380
458
458
480
480
500
500
620
620
740
762
860
914
980
120
150
190
150
260
260
300
306
260
260
382
382
480
480
350
350
450
450
550
508
640
610
740
80
90
100
130
160
205
160
205
160
205
160
205
160
205
160
205
160
205
205
205
205
205
205
DIMENSIONS
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 13
Composite
C M Y CM MY CY CMY K
12
HADAR LIGHTING
Zone 1 MODULAR LED LUMINAIRE/FLOODLIGHT - HDL 106
Modular construction allows the modules to be interlinked with each other
to provide greater light output.
Can be used as a single unit - small floodlight or bulkhead or be linked together
to replicate a large 250W/400W floodlight.
Each module utilises 48 off 1.2W LEDs.
Integrated power supply.
Low power consumption.
Rugged construction - resistant to vibration.
Independently photometrically tested.
All units supplied with 2 cable entries.
IP66 and IP67.
Optional wire guard available for extra protection.
Infra red variants available.
Wide, medium and narrow beam light output available.
In comparison to typical Ex d floodlights -
60% less weight.
50% less power consumption.
One man installation.
LED technology will give a predicted Lamp life of 10 years+.
No light pollution.
Instant restrike.
No light degradation at low temperatures.
Penetrating white light.
Photocell option available.
No flamepaths to maintain.
Low cost of installation, operation and maintenance.
KEY FEATURES - Modular LED Luminaire/Floodlight/ZONE 1 Ex em
-50ºC to +55ºC
DIMENSIONS
PROTECTION II 2GD Ex emb II T4/T5/T6 IP66/67, Ex tD A21 T100ºC
CERTIFICATION ATEX & IEC Ex PENDING BY SIRA
Certification Ambient Certificate
HDL106 II 2GD Ex emb II T4/T5/T6
IP66/67
ATEX and IEC Ex pending
Voltage Range
110V to 254V
SPECIFICATION
Main Body Marine Grade Aluminium
Diffuser Toughened Glass 5mm
Gaskets Silicone
External Fasteners A4 Stainless Steel
Stirrup Bracket Steel Painted or
316 Stainless Steel
T Rating T4/T5/T6
Surface Temp 100ºC
Weight 6.0kg per module
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 14
Composite
C M Y CM MY CY CMY K
13
HADAR LIGHTING
Zone 1 MODULAR LED LUMINAIRE/FLOODLIGHT - HDL 106
48 x 1.2W LED's
96 x 1.2W LED's
144 x 1.2W LED's
ELECTRICAL SPECIFICATIONS
Lamp Options
Power consumption Power factor Power supply
Electrical Specification
ORDERING MATRIX
Field Options
Up to 6mm 2 clamp terminals for live, neutral, earth and looping are provided. Internal and external earth as standard.
Screw terminals upon request.
Installation document AL10320 supplied.
2 x M20, one fitted with approved stopper plug, other entries available on request.
INSTALLATION
Terminals
Cable Entries
Via stirrup bracket, other mounting accessories available.Suspension
Installation
1) Typical ordering reference HDL1061W0000.
2) For Photometric Data contact the sales office.
Notes
Product
Version
Fittings
0.95 110V - 254V 47/63Hz AC/DC
Cable Entries
Other Options
80W Max
160W Max
240W Max
Beam Pattern
HDL106
1 - 48 LED's
2 - 96 LED's
3 - 144 LED's
W - Wide
M - Medium
N - Narrow
0 - Painted steel external brackets
1 - 316 SS external brackets
0 - M20
5 - M25
00 - Standard
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 15
Composite
C M Y CM MY CY CMY K
2 x 18W Compact fluorescent lamp for mains operation.
Ideal for exit signs - wall or ceiling mounted.
Visible Glass area 300mm x 150mm (standard size for fire exit signage).
Mild Steel painted as standard (Stainless steel also available).
Simple Installation.
Straightforward maintenance.
Recessed or surface mounting.
For Standard Ex em Recessed Luminaire see data sheet HDL 102.
Lightweight and robust construction.
Mounting in any attitude.
Low profile.
Continuous monitoring of fluorescent lamps ensures safe end of life shutdown.
by electronic ballast in accordance with HSE safety notice 8/05.
Overvoltage protection 320V for 1 minute.
Quick lamp start and flicker free operation control gear.
Cable entries in any face or rear.
Can be supplied with signage or facility for end user to fit own.
Other warning signage can be used.
EMERGENCY VERSION
Standard emergency - one fluorescent lamp
remains at a reduced output. Can be operated
maintained or non maintained.
HADAR LIGHTING
Zone 1 Ex em BULKHEAD FIRE EXIT RECESSED LUMINAIRE - HDL 108
KEY FEATURES - Zone 1 Ex em Bulkhead Fire Exit Recessed Luminaire
14
Standard Range -40ºC to +55ºC T3
-40ºC to +35ºC T4
Emergency range -15ºC to +55ºC T3
-15ºC to +35ºC T4
DIMENSIONS
PROTECTION II 2GD Ex emb II T3/T4 IP64
Ex tD A21 T90ºC
CERTIFICATION ATEX & IEC Ex CERTIFIED BY SIRA
Certification Ambient Certificate
HDL 108 II 2GD Ex emb II T3/T4 IP64 IEC Ex SIR 06.0027
SIRA 06 ATEX 3080
Voltage Range
110V - 254V
2 x 18W Std 3kg
2 x 18W Emergency 3.5kg
Weight
Incorporates the new ''End of Life'' (EoL) protection circuit ballast -
according to DIN EN 61347-2-3 and IEC 60079-7 Ed.4 Annex H
Lamp
FIRE EXIT SIGN
Visible glass area 300mm x 150mm (standard size
for fire exit signage) Wall or ceiling mounted.
Can be supplied with signage or facility for end
user to fit own.
Other warning signage can be used.
(Surface Mount Variant)
SPECIFICATION
Enclosure Steel Powder Coated
Diffuser Frame Or Stainless Steel
Diffuser Toughened Prismatic Glass
Gasket Silicone
External Fasteners A4 Stainless Steel
T Rating T3/T4 Gas and Dust
Surface Temp 90ºC
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 16
Composite
C M Y CM MY CY CMY K
15
Better 220V - 254V, 47/63 Hz AC/DC
Than 110V - 130V, 47/63 Hz AC/DC
0.95 Emergency version as above - AC only
ELECTRICAL SPECIFICATIONS
Lamp Options
Power consumption Power factor Power supply
Electrical Specification
HADAR LIGHTING
Zone 1 Ex em BULKHEAD FIRE EXIT - RECESSED LUMINAIRE - HDL 108
HDL108
S - Non Emergency
E - Emergency
R - Recessed
S - Surface Mount
H - High Voltage (220V - 254V)
M - Medium Voltage (110V - 130V)
0 - M20 Entries
5 - M25 Entries
218 - 2 x 18W
ORDERING MATRIX
Field 0ptions
Fittings
Voltage
Cable Entries
Up to 6mm2 clamp terminals for live, live switched, neutral, earth and looping are provided. Internal and external earth as standard.
Screw terminals upon request
Installation document AL10091 supplied
To suit individual customer requirements
INSTALLATION
Terminals
Cable Entries
Via internal mounting holesSuspension
Installation
1) Final Product Code should be in the format: HDL108SRH0218
2) Please specify any signage required at the point of ordering.
3) Mild steel as standard, contact the sales office for stainless steel.
4) For Photometric Data contact the sales office.
Notes
Product
Version
Lamp Options
2 x 18W CFL STD 32W circuit watts at 240V - 0.14A (120V - 0.28A)
2 x 18W CFL EM 36W circuit watts at 240V - 0.15A (120V - 0.3A)
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 17
Composite
C M Y CM MY CY CMY K
2 x 18W Compact fluorescent lamp for mains operation or emergency option.
Ideal for exit signs - wall or ceiling mounted.
Simple Installation.
Straightforward maintenance.
Emergency version available.
Various colour diffusers available - suitable for Helideck or obstruction type lighting.
Lightweight and robust construction.
Short gaskets for proven ingress protection.
Mounting in any attitude.
Features mounting points compatible with Unistrut support systems and accessories.
Low Profile.
Continuous monitoring of fluorescent lamps ensures safe end of life shutdown by
electronic ballast in accordance with HSE safety notice 8/05.
Overvoltage protection 320V for 1 minute.
Quick lamp start and flicker free operation control gear.
Supplied complete with lamps.
Uses standard compact fluorescent lamps.
Bulkhead fitting interchangeable with spares of Hadar Exe Fluorescent Luminaire.
EMERGENCY VERSION
Standard emergency - one fluorescent lamp
remains at a reduced output.
Can be operated maintained or non maintained.
HADAR LIGHTING
Zone 1 Ex em BULKHEAD FIRE EXIT LUMINAIRE - PLASTIC - HDL 109
KEY FEATURES - Zone 1 Ex em Bulkhead / Fire Exit Luminaire - Plastic
SPECIFICATION
Enclosure Polycarbonate
Mounting Bracket Aluminium or Steel
Powder Coated
Gasket Silicone
External Fasteners A4 Stainless Steel
T Rating T3 Gas and Dust
Surface Temp 100ºC
Standard Range -20ºC to +40ºC
Emergency Range -15ºC to +40ºC
DIMENSIONS
PROTECTION II 2GD Ex emb II T3 IP66/67
Ex tD A21 T100ºC
CERTIFICATION ATEX & IEC Ex CERTIFIED BY SIRA
Certification Ambient Certificate
HDL 109 II 2GD Ex emb II T3 IP66/67 IEC Ex SIR060026X
SIRA 06 ATEX 3079X
Voltage Range
110V - 254V
2 x 18W
Weight
Incorporates the new ''End of Life'' (EoL) protection circuit ballast - according
to DIN EN 61347-2-3 and IEC 60079-7 Ed.4 Annex H
Lamp
FIRE EXIT SIGN
Wall or ceiling mounted.
Can be supplied with signage or facility for end
user to fit own.
Other warning signage can be used.
2.5kg
16
2 x 18W Emergency 3kg
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 18
Composite
C M Y CM MY CY CMY K
17
HADAR LIGHTING
Zone 1 Ex em BULKHEAD FIRE EXIT LUMINAIRE - PLASTIC - HDL 109
Better 220V - 254V, 47/63 Hz AC/DC
Than 110V - 130V, 47/63 Hz AC/DC (2 x 18W/2 x 36W only)
0.95 Emergency version as above - AC Only
ELECTRICAL SPECIFICATIONS
Lamp Options
Power consumption Power factor Power supply
Electrical Specification
HDL109
S - Non Emergency
E - Emergency
U - Loop In/Out (Unistrut)
L - Loop In/Out (Bracket)
P - Pole Mount
H - High Voltage (220V - 254V)
M - Medium Voltage (110V - 130V)
0 - M20 Entries
5 - M25 Entries
218 - 2 x 18W
ORDERING MATRIX
Field Options
Fittings
Voltage
Cable Entries
Up to 6mm2 clamp terminals for live, live switched, neutral, earth and looping are provided. Internal and external earth as standard.
Screw terminals upon request.
Installation document AL10090 supplied.
2 x M20. Pole mount fittings supplied with 1 x M20 other entries available on request.
INSTALLATION
Terminals
Cable Entries
Via bracket supplied or Unistrut reflector.Suspension
Installation
1) Final Product Code should be in the format: HDL109SUH0218
2) For Photometric Data contact the sales office.
3) Brass earth continuity gland plates are available, contact sales office for
more information.
Notes
Product
Version
Lamp Options
2 x 18W CFL STD 32W circuit watts at 240V - 0.14A (120V - 0.28A)
2 x 18W CFL EM 36W circuit watts at 240V - 0.15A (120V - 0.3A)
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 19
Composite
C M Y CM MY CY CMY K
Simple installation.
Straightforward maintenance.
Integral control gear - easily removed.
Wide choice of voltage and lamp options.
Ex e terminal chamber.
Internal flamepaths eliminating risk of corrosion and costly damage.
Control gear and associated components housed in separate
easily removed assembly.
The unique innovative design allows luminaires to be easily converted.
from Zone 1 to Zone 2 and vice versa.
Lamp types and wattages can also be easily changed by new easily
removed control gear assembly.
Elliptical or tubular lamps.
Zone 2 variants available.
Optional external reflector - ideal for warehousing.
KEY FEATURES - Zone 1 Ex ed or Ex de Wellglass
SPECIFICATION
Main Body Marine Grade Aluminium
Lamp Glass Toughened Glass
External Fasteners A4 Stainless Steel
T Rating T3/T4/T5
Surface Temperature 195ºC
External Reflecter Aluminium
-20ºC to +50ºC
PROTECTION II 2GD Ex ed or de IIC T3 IP66/67
Ex tD A21 195ºC
CERTIFICATION ATEX & IEC Ex CERTIFIED BY SIRA
Certification Ambient Certificate
HDL 133
HDL 134
HDL 113
HDL 114
II 2GD Ex ed or de IIC T3 IP66/67 Certificate pending
Voltage Range
see table
below
DIMENSIONS
DescriptionType
55W & 85W QL LAMPS
165W QL LAMPS
50W to 150W
SON, MBI, MBF, GLS
150W to 400W
SON, MBI, MBF, GLS
110V to 130V
220V to 240V 50/60Hz AC/DC
220V to 240V 50/60Hz AC/DC
220V, 230V, 240V, 250V
50/60Hz
220V, 230V, 240V, 250V
50/60Hz
Voltage
HADAR LIGHTING
Zone 1 WELLGLASS - HDL 113 - HDL 114 - HDL 133 - HDL 134
18
Weight
10kg
15kg
13kg
18kg
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 20
Composite
C M Y CM MY CY CMY K
19
HADAR LIGHTING
Zone 1WELLGLASS - HDL 113 - HDL 114 - HDL 133 - HDL 134
HDL133S
HDL134S
HDL113S
HDL114S
11 – 110V
22 – 220V
23 – 230V
24 – 240V
25 – 250V
5 – 50Hz
6 – 60Hz
00 – 2 x M20
05 – 2 x M25
55 – 55W
85 – 85W
165 – 165W
50 – 50W
70 – 70W
80 – 80W
100 – 100W
125 – 125W
150 – 150W
250 – 250W
400 – 400W
Q – QL Lamp
M – MBF Mercury
H – MBI Metal Halide
E – SON High Pressure Sodium
G – GLS
ORDERING MATRIX
Field Options
Voltage
Product
Frequency
Cable Entries
Lamp Options
Options
Up to 6mm2 clamp terminals for live, live switched, neutral,
earth and looping are provided. Internal and external earth
as standard.
Installation document AL10173 supplied.
2 x M20. Other entries available on request
INSTALLATION
Terminals
Cable Entries
Via stirrup bracket supplied. See drawings opposite.Suspension
Installation
Notes
1) Final Product Code should be in the format: HDL113S24500400E
2) For Photometric Data contact the sales office.
3) External reflector item no. ALA90056.
0.95
0.85
ELECTRICAL SPECIFICATIONS
Lamp Options
Lamp holder Power factor Power consumption
Electrical Specification
55W QL
85W QL
165W QL
50W MBF
80W MBF
125W MBF
250W MBF
400W MBF
50W SON
70W SON
150W SON
250W SON
400W SON
70W MBI
100W MBI
150W MBI
250W MBI
400W MBI
500W (Max) GLS
N/A
N/A
N/A
E27
E27
E27
E40
E40
E27
E27
E40
E40
E40
E27
E27
E27
E40
E40
E40
60W
95W
182W
55W
90W
140W
280W
440W
55W
80W
170W
275W
440W
80W
115W
170W
280W
440W
500W
Ex de
Ex ed
CERTIFICATION
Type
Ex ed
Certification
Ex de
HDL 113
HDL 133
HDL 134
HDL 114
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 21
Composite
C M Y CM MY CY CMY K
150W, 250W and 400W discharge lamps.
500W max tungsten halogen lamp.
Simple installation.
Straightforward maintenance.
Integral control gear.
wide choice of voltage options.
Marine grade aluminium.
Lightweight.
Robust.
Ex e junction box.
Suitable for use with twin arc lamps.
Wide beam reflector.
KEY FEATURES - Zone 1 Ex de Floodlight
SPECIFICATION
Main Body Marine Grade Aluminium
Lamp Glass Toughened Soda Lime
External Fasteners A4 Stainless Steel
T Rating T2 and T3
150W -20ºC to +40ºC T3
250W -20ºC to +40ºC T3
400W -20ºC to +40ºC T3 (110V, 120V, 220V)
400W -20ºC to +40ºC T2 (230V / 240V)
500W -20ºC to +40ºC T2
DIMENSIONS
PROTECTION II 2G Ex de IIB T2/T3 IP56
CERTIFICATION ATEX & IEC Ex CERTIFIED BY SIRA
Certification Ambient Certificate
HDL 117 II 2G Ex de IIB T2/T3 IP56 IEC Ex SIR 07.0023
SIRA 07 ATEX 1059
Voltage Range
110V to 240V
Discharge 20 kg
GLS / TH 15 kg
WeightLamp
HADAR LIGHTING
Zone 1 FLOODLIGHT - HDL 117
20
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 22
Composite
C M Y CM MY CY CMY K
Exe terminal chamber with terminal block suitable for looping 6mm2 cable.
2 x M20 (other entries available on request).
INSTALLATION
Terminals
Cable Entries
Steel mounting bracket. See dimensions above for fixing.Suspension
ELECTRICAL SPECIFICATIONS
150W
250W
400W
500W
Lamp Options
Power consumption Power factor Power supply
Electrical Specification
170W
280W
435W
500W
0.85
110V, 120V, 220V, 230V
240V, 50/60 Hz
21
HADAR LIGHTING
Zone 1 FLOODLIGHT - HDL 117
Installation Installation document AL10204 supplied.
HDL 117S
11 – 110V
12 – 120V
22 – 220V
23 – 230V
24 – 240V
5 – 50Hz
6 – 60Hz
0 – 2 x M20
5 – 2 x M25
150 - 150W
250 – 250W
400 – 400W
500 – 500W
H – MBI Metal Halide
E – SON High Pressure Sodium
T – Tungsten Halogen
ORDERING MATRIX
Field Options
Voltage
Product
Frequency
Cable Entries
Lamp Options
Options
1) Final Product Code should be in the format: HDL117S2450400E
2) For Photometric Data contact the sales office.
Notes
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 23
Composite
C M Y CM MY CY CMY K
The Zone 2 EEx nA Fluorescent Luminaire is designed from a high specification of
corrosion resistant glass reinforced polyester body and high impact polycarbonate diffuser
to give the highest protection to ATEX standards for EEx nA applications.
The luminaire features stainless steel diffuser retaining clips and zinc steel gear tray for
rapid installation and easy maintenance.
18W, 36W, 58W Single or Twin.
High specification.
SIRA certified.
Rapid installation.
Ease of maintenance.
Certified components.
High Frequency Electronic Ballast.
High Impact GRP Base.
High Impact Polycarbonate Diffuser.
Stainless Steel Diffuser Clips As Standard.
Loop-in/Loop-Out as standard.
Through wired versions available.
Low Smoke Zero Halogen Option.
IP65
EMERGENCY VERSION
Twin Unit
3 Hour Battery duration
HADAR LIGHTING
Zone 2 EEx nA FLUORESCENT LUMINAIRE - EMERGENCY FLUORESCENT - HDL 220
KEY FEATURES - Zone 2 EEx nA Fluorescent Luminaire / Emergency Fluorescent
22
SPECIFICATION
Enclosure Corrosion resistant
Glass reinforced polyester
Diffuser High Impact Polycarbonate
Retaining Clips Stainless Steel
Gear Tray Zinc Steel Painted
Control Gear High Frequency Electronic
T Rating T4 Gas and Dust
58W also available in T3
Surface Temp 140ºC
Standard Range
18W -20ºC to +40ºC T4
36W -20ºC to +40ºC T4
58W -20ºC to +50ºC T3
-20ºC to +40ºC T4
Emergency Range
18W -15ºC to +40ºC T4
36W -15ºC to +40ºC T4
58W -15ºC to +40ºC T4
DIMENSIONS
PROTECTION Ex II 3GD EEx nA II T3/T4 IP65 T140ºC
CERTIFICATION ATEX CERTIFIED BY SIRA
Certification Ambient Certificate
HDL 220 Standard
Ex II 3GD EEx nA II T3/T4 IP65
Emergency
Ex II 3GD EEx nC T4 IP65
SIRA 03ATEX 4566X
Voltage Range
220V - 240V
1 x 18W Luminaires
1 x 36W Luminaires
1 x 58W Luminaires
2 x 18W Luminaires
2 x 36W Luminaires
2 x 58W Luminaires
L CFW H
702
1312
1612
702
1312
1612
116
116
116
186
186
186
114
114
114
114
114
114
500
800
1100
500
800
1100
480 x 2 clips per side
400 x 4 clips per side
380 x 5 clips per side
Weight
Contact Sales Office
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 24
Composite
C M Y CM MY CY CMY K
23
1 x 18W (600mm Luminaire) 20W
1 x 36W (1200mm Luminaire) 38W
1 x 58W (1500mm Luminaire) 60W 220V - 240V, 47/63 Hz AC/DC
2 x 18W (600mm Luminaire) 39W (Emergency - 49W) Emergency version AC only
2 x 36W (1200mm Luminaire) 73W (Emergency - 83W)
2 x 58W (1500mm Luminaire) 113W (Emergency - 132W)
ELECTRICAL SPECIFICATIONS
Lamp Options
Power consumption Power factor Power supply
Electrical Specification
HADAR LIGHTING
Zone 2 EEx nA FLUORESCENT LUMINAIRE - EMERGENCY FLUORESCENT - HDL 220
HDL220
S - Non Emergency
E - Emergency
L - Loop In/Loop Out
T - Through Wired
118 - 1 x 18W
136 - 1 x 36W
158 - 1 x 58W
218 - 2 x 18W
236 - 2 x 36W
258 - 2 x 58W
ORDERING MATRIX
Field 0ptions
Fittings
Suitable for up to 4.00mm2 cable. 6.00mm2 on request.
Through Wiring available (Loop In/Loop Out as standard) Low smoke zero halogen available.
20mm clearance holes.
INSTALLATION
Terminals
Cable Entries
To suit individual customer requirements.Suspension
Options
1) Final Product code should be in the format: HDL220SL118
2) For Photometric data contact the sales office.
Notes
Product
Version
Lamp Options
Better
Than
0.95
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 25
Composite
C M Y CM MY CY CMY K
55W & 85W QL LAMPS
165W QL LAMPS
50W to 150W
SON, MBI, MBF, GLS
150W to 400W
SON, MBI, MBF, GLS
Simple installation.
Straightforward maintenance.
Integral control gear - easily removed.
Wide choice of voltage and lamp options.
Ex e terminal chamber.
Internal flamepaths eliminating risk of corrosion and costly damage.
Control gear and associated components housed in separate
easily removed assembly.
The unique innovative design allows luminaires to be easily converted.
from Zone 1 to Zone 2 and vice versa.
Lamp types and wattages can also be easily changed by new easily
removed control gear assembly.
Elliptical or tubular lamps.
Zone 1 variants available.
Optional external reflector - ideal for warehousing.
KEY FEATURES - Zone 2 Ex nR Wellglass
SPECIFICATION
Main Body Marine Grade Aluminium
Lamp Glass Toughened Glass
External Fasteners A4 Stainless Steel
T Rating T3/T4/T5
Surface Temperature 195ºC
External Reflecter Aluminium
-20ºC to +50ºC
PROTECTION II 2GD Ex nR II T3 IP66/67
CERTIFICATION ATEX & IEC Ex CERTIFIED BY SIRA; ABS APPROVED FOR MARINE USE
Certification Ambient Certificate
HDL 233
HDL 234
HDL 213
HDL 214
II 2GD Ex nR or de IIC T3 IP66/67 Certificate pending
Voltage Range
see table
below
DIMENSIONS
DescriptionType
110V to 130V
220V to 240V 50/60Hz AC/DC
220V to 240V 50/60Hz AC/DC
220V, 230V, 240V, 250V
50/60Hz
220V, 230V, 240V, 250V
50/60Hz
Voltage
HADAR LIGHTING
Zone 2 Ex nR WELLGLASS - HDL - 223- 224 - 233 - 234
24
Weight
10kg
15kg
13kg
18kg
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 26
Composite
C M Y CM MY CY CMY K
25
HADAR LIGHTING
Zone 2 Ex nR WELLGLASS - HDL - 223- 224 - 233 - 234
HDL233S
HDL234S
HDL223S
HDL224S
11 – 110V
22 – 220V
23 – 230V
24 – 240V
25 – 250V
5 – 50Hz
6 – 60Hz
00 – 2 x M20
05 – 2 x M25
55 – 55W
85 – 85W
165 – 165W
50 – 50W
70 – 70W
80 – 80W
100 – 100W
125 – 125W
150 – 150W
250 – 250W
400 – 400W
Q – QL Lamp
M – MBF Mercury
H – MBI Metal Halide
E – SON High Pressure Sodium
G – GLS
ORDERING MATRIX
Field Options
Voltage
Product
Frequency
Cable Entries
Lamp Options
Options
Up to 6mm2 clamp terminals for live, live switched, neutral,
earth and looping are provided. Internal and external earth
as standard.
Installation document AL10173 supplied.
2 x M20. Other entries available on request
INSTALLATION
Terminals
Cable Entries
Via stirrup bracket supplied. See drawings opposite.Suspension
Installation
1) Final Product Code should be in the format: HDL223S24500400E
2) For Photometric Data contact the sales office.
3) External reflector item no. ALA90056.
Notes
0.95
0.85
ELECTRICAL SPECIFICATIONS
Lamp Options
Lamp holder Power factor Power consumption
Electrical Specification
55W QL
85W QL
165W QL
50W MBF
80W MBF
125W MBF
250W MBF
400W MBF
50W SON
70W SON
150W SON
250W SON
400W SON
70W MBI
100W MBI
150W MBI
250W MBI
400W MBI
500W (Max) GLS
N/A
N/A
N/A
E27
E27
E27
E40
E40
E27
E27
E40
E40
E40
E27
E27
E27
E40
E40
E40
60W
95W
182W
55W
90W
140W
280W
440W
55W
80W
170W
275W
440W
80W
115W
170W
280W
440W
500W
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 27
Composite
C M Y CM MY CY CMY K
The HDL 227 marine grade aluminium alloy floodlight with high performance
photometrics is designed to withstand highly corrosive and Zone 2 hazardous area
environments.
The EEx nR restricted breathing floodlight is constructed from a compact and
lightweight design and is available in 150W, 250W and 400W high pressure
sodium or metal halide.
150W, 250W, 400W.
High performance photometrics.
Restricted breathing.
SIRA certified.
Lightweight design.
High pressure sodium/metal halide.
Marine Grade Alloy Body.
Hinged Front Cover.
Toughened Glass.
Compact & Lightweight Design.
Loop-in, Loop-out as standard.
Stirrup Bracket, Galvanised Steel.
Stainless Steel Cover & Bracket Screws.
IP65.
HADAR LIGHTING
Zone 2 EEx nR FLOODLIGHT - HDL 227
KEY FEATURES - Zone 2 EEx nR Floodlight
26
-40ºC to +56ºC
PROTECTION Ex II 3GD EEx nR II T3/T2 IP65
CERTIFICATION ATEX CERTIFIED BY SIRA
Certification Ambient Certificate
HDL 227 Ex II 3GD EEx nR II T3/T2 IP65 SIRA 03ATEX 4061
Voltage Range
220V - 240V
SPECIFICATION
Body Marine Grade Aluminium Alloy LM6
Front Hinged Front Cover
Diffuser Toughened Glass 4mm
Reflector Symmetrical Dimpled
Control Gear Anodised Polished Aluminium
Stirrup Bracket Galvanised Steel
Cover Stainless Steel
Bracket Screws Stainless Steel
DIMENSIONS
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 28
Composite
C M Y CM MY CY CMY K
1) Final Product Code should be in the format: HDL227400SON.
2) For Photometric and Weight Data contact the sales office.
0º -40ºC to +40ºC -40ºC to +56ºC
30º -40ºC to +38ºC -40ºC to +56ºC
45º -40ºC to +37ºC -40ºC to +56ºC
60º -40ºC to +35ºC -40ºC to +56ºC
90º -40ºC to +31ºC -40ºC to +45ºC
0º -40ºC to +40ºC -40ºC to +56ºC
30º -40ºC to +38ºC -40ºC to +56ºC
45º -40ºC to +37ºC -40ºC to +56ºC
60º -40ºC to +35ºC -40ºC to +56ºC
90º -40ºC to +31ºC -40ºC to +45ºC
0º -40ºC to +35ºC -40ºC to +35ºC
30º -40ºC to +35ºC -40ºC to +35ºC
45º -40ºC to +30ºC -40ºC to +35ºC
60º -40ºC to +25ºC -40ºC to +25ºC
90º -40ºC to +25ºC -40ºC to +25ºC
AMBIENTS / MOUNTING ATTITUDES
W Attitude Point
150W
T3
PFC NO PFC
250W
T3
400W
T2
27
HADAR LIGHTING
Zone 2 EEx nR FLOODLIGHT - HDL 227
HDL227
150W - 150W
250W - 250W
400W - 400W
SON - High Pressure Sodium
MBI - Metal Halide
ORDERING MATRIX
Field Options
Options
Notes
Product
Lamp Options
150W 168W Better
250W 280W Than
400W 433W 0.85
ELECTRICAL SPECIFICATIONS
Lamp Options
Power consumption Power factor Power supply
Electrical Specification
Suitable for up to 4.00mm cable.
2 x M20 (other cable entries available upon request).
INSTALLATION
Terminals
Cable Entries
See dimensional diagram.Suspension
220V - 240V 50 Hz AC
Other voltages and frequencies available upon request.
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 29
Composite
C M Y CM MY CY CMY K
A-Belco Hazardous Area
A-Belco Hazardous Area
A-Belco Hazardous Area is a specialist manufacturer of hazardous area products for the
oil, gas, petro-chemical, pharmaceutical and marine industries worldwide. A division of
the A-Belco Group, A-Belco Hazardous Area is an independent UK based manufacturer
providing standard and bespoke offerings in the design and assembly of products for
Zone Classification Areas 1, 2, 21 & 22, Gas and Dust.
The portfolio of products includes Junction Boxes, Control Panels, Control Stations,
Lighting, Receptacles, Switches, Circuit Breakers, Cable Glands - all within Ex d, Ex e,
Ex ia, Ex nA and Ex nR protection concepts. All products are built in conformance with
the ATEX Directive to ensure complete safety. The equipment is independently certified
by SIRA, CESI, GOST-R, GOST-K and AUS.
Junction Boxes
Manufactured from a range of materials including Aluminium Alloy, Stainless Steel and
GRP the A-Belco range of explosion-proof Junction Boxes are suitable for use in Zone
Classification Areas 1, 2, 21 & 22. The extensive range of enclosures can be used as
Junction Boxes with or without terminals and to install electrical equipment such as
switches, indicators, ammeters, voltmeters, section switches, remote control switches
and transformers.
Drilled and threaded to individual customer requirements, optional upgrades include;
internal mounting frames, air and drain valves, internal anti-condensate coating, tempered
glass windows and IP kits. These robust boxes are suitable for use in any industrial
processing plant where the presence of gas, vapours and flammable powders could
potentially create an explosive atmosphere.
Cable Glands
Our innovative range of explosion-proof and weather-proof cable glands are used to
provide a connection with electrical equipment that is housed within a flame-proof
enclosure; providing a seal that will maintain the specific level of protection that is required.
Suitable for use in Zone 1, 2, 21 & 22 Hazardous Areas with all types of armoured cable,
the cable glands provide a compound barrier seal around the cable conductors and an
environmental seal around on the cable outer sheath. In addition the gas tight seal has
been tested to prove compatible with Restricted Breathing equipment.
The cable glands allow mechanical cable retention and earth continuity via the cable
armour termination. Manufactured in a range of sizes and configurations to suit individual
requirements, the cable glands are available off-the-shelf at competitive prices within
short lead times.
A-Belco Group
The A-Belco Group is a diverse group of companies offering electrical and mechanical
engineering excellence to a wide range of industries and markets worldwide. Through an
extensive range of skills and experience, the A-Belco Group has significant engineering
and design capabilities to provide a complete and bespoke first class engineered solution
from design to manufacture.
The Group incorporates A-Belco Hazardous Area, A-Belco Electrical Engineering, A-Belco
Industrial Connectors and MEP Solutions.The extensive product portfolio includes
switchgear, electrical distribution panels, electrical accessories and innovative modular
building service solutions. Formerly Reyrolle Industrial Accessories and later BALS
Engineering, the Group is an established supplier to the UK energy, rail and construction
markets. With over 25 years experience in the energy sector, A-Belco excels in quality,
price, delivery and after sales support.
28
HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 30
Composite
C M Y CM MY CY CMY K
We reserve the right to amend technical data in accordance with continuous improvement of product specifications and standards.
Please refer to the website www.a-belco.co.uk/hazardous or contact the sales office for the latest literature revision.
NOTES
Hazardous Interim Cover.FH11 Sat Feb 07 11:04:56 2009 Page 1
Composite
C M Y CM MY CY CMY K
H A Z A R D O U S A R E A
A-BELCO
CABLE JOINTS, CABLE TERMINATIONS, CABLE GLANDS, CABLE CLEATS
FEEDER PILLARS, FUSE LINKS, ARC FLASH, CABLE ROLLERS, CUT-OUTS
11KV 33KV CABLE JOINTS & CABLE TERMINATIONS
FURSE EARTHING
www.cablejoints.co.uk
Thorne and Derrick UK
Tel 0044 191 490 1547 Fax 0044 191 477 5371
Tel 0044 117 977 4647 Fax 0044 117 9775582

Weitere ähnliche Inhalte

Was ist angesagt?

Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT150 - 150W ...
Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT150 - 150W ...Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT150 - 150W ...
Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT150 - 150W ...Thorne & Derrick International
 
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood Light
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood LightZone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood Light
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood LightThorne & Derrick International
 
Zone 1 (ATEX) Recessed Luminaires Hadar HDL102 - (Twin 18 Watts)
Zone 1 (ATEX) Recessed Luminaires Hadar HDL102 - (Twin 18 Watts)Zone 1 (ATEX) Recessed Luminaires Hadar HDL102 - (Twin 18 Watts)
Zone 1 (ATEX) Recessed Luminaires Hadar HDL102 - (Twin 18 Watts)Thorne & Derrick International
 
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108, (32 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108, (32 Watts)Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108, (32 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108, (32 Watts)Thorne & Derrick International
 
Wolf - Hazardous Area Portable & Temporary Lighting - Brochure
Wolf - Hazardous Area Portable & Temporary Lighting - BrochureWolf - Hazardous Area Portable & Temporary Lighting - Brochure
Wolf - Hazardous Area Portable & Temporary Lighting - BrochureThorne & Derrick UK
 
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL109 (32 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL109 (32 Watts)Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL109 (32 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL109 (32 Watts)Thorne & Derrick International
 
ABB ATEX Industrial Plugs & Sockets - Hazardous Area Plugs & Sockets
ABB ATEX Industrial Plugs & Sockets - Hazardous Area Plugs & SocketsABB ATEX Industrial Plugs & Sockets - Hazardous Area Plugs & Sockets
ABB ATEX Industrial Plugs & Sockets - Hazardous Area Plugs & SocketsThorne & Derrick International
 
Marechal SPeX ATEX Plug & Socket Power Connector - Zones 1, 2 21, 22
Marechal SPeX ATEX Plug & Socket Power Connector - Zones 1, 2 21, 22Marechal SPeX ATEX Plug & Socket Power Connector - Zones 1, 2 21, 22
Marechal SPeX ATEX Plug & Socket Power Connector - Zones 1, 2 21, 22Thorne & Derrick International
 
Thermon KSR-2 Heat Tracing Cable - Spec Sheet
Thermon KSR-2 Heat Tracing Cable - Spec SheetThermon KSR-2 Heat Tracing Cable - Spec Sheet
Thermon KSR-2 Heat Tracing Cable - Spec SheetThorne & Derrick UK
 
Wolf Portable Lighting Catalogue - Torches, Head & Hand Lamps
Wolf Portable Lighting Catalogue - Torches, Head & Hand LampsWolf Portable Lighting Catalogue - Torches, Head & Hand Lamps
Wolf Portable Lighting Catalogue - Torches, Head & Hand LampsThorne & Derrick International
 
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting Thorne & Derrick International
 
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous AreaStahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous AreaThorne & Derrick International
 
Explosion Proof Lights in Stock
Explosion Proof Lights in StockExplosion Proof Lights in Stock
Explosion Proof Lights in StockProject Sales Corp
 
Stahl TEF 2430 Green Perimeter Light - ATEX Zone 1 Zone 2 Hazardous Area
Stahl TEF 2430 Green Perimeter Light - ATEX Zone 1 Zone 2 Hazardous AreaStahl TEF 2430 Green Perimeter Light - ATEX Zone 1 Zone 2 Hazardous Area
Stahl TEF 2430 Green Perimeter Light - ATEX Zone 1 Zone 2 Hazardous AreaThorne & Derrick International
 
Hadar - Hadar Lighting For Hazardous Areas (Zone 1 & Zone 2 - ATEX Certified)
Hadar - Hadar Lighting For Hazardous Areas (Zone 1 & Zone 2 - ATEX Certified)Hadar - Hadar Lighting For Hazardous Areas (Zone 1 & Zone 2 - ATEX Certified)
Hadar - Hadar Lighting For Hazardous Areas (Zone 1 & Zone 2 - ATEX Certified)Thorne & Derrick International
 
Marechal DXN ATEX Plug & Socket Outlets (Decontactors) for Hazardous Areas Zo...
Marechal DXN ATEX Plug & Socket Outlets (Decontactors) for Hazardous Areas Zo...Marechal DXN ATEX Plug & Socket Outlets (Decontactors) for Hazardous Areas Zo...
Marechal DXN ATEX Plug & Socket Outlets (Decontactors) for Hazardous Areas Zo...Thorne & Derrick International
 

Was ist angesagt? (17)

Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT150 - 150W ...
Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT150 - 150W ...Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT150 - 150W ...
Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT150 - 150W ...
 
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood Light
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood LightZone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood Light
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood Light
 
Zone 1 (ATEX) Recessed Luminaires Hadar HDL102 - (Twin 18 Watts)
Zone 1 (ATEX) Recessed Luminaires Hadar HDL102 - (Twin 18 Watts)Zone 1 (ATEX) Recessed Luminaires Hadar HDL102 - (Twin 18 Watts)
Zone 1 (ATEX) Recessed Luminaires Hadar HDL102 - (Twin 18 Watts)
 
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108, (32 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108, (32 Watts)Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108, (32 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108, (32 Watts)
 
Wolf - Hazardous Area Portable & Temporary Lighting - Brochure
Wolf - Hazardous Area Portable & Temporary Lighting - BrochureWolf - Hazardous Area Portable & Temporary Lighting - Brochure
Wolf - Hazardous Area Portable & Temporary Lighting - Brochure
 
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL109 (32 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL109 (32 Watts)Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL109 (32 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL109 (32 Watts)
 
ABB ATEX Industrial Plugs & Sockets - Hazardous Area Plugs & Sockets
ABB ATEX Industrial Plugs & Sockets - Hazardous Area Plugs & SocketsABB ATEX Industrial Plugs & Sockets - Hazardous Area Plugs & Sockets
ABB ATEX Industrial Plugs & Sockets - Hazardous Area Plugs & Sockets
 
Marechal SPeX ATEX Plug & Socket Power Connector - Zones 1, 2 21, 22
Marechal SPeX ATEX Plug & Socket Power Connector - Zones 1, 2 21, 22Marechal SPeX ATEX Plug & Socket Power Connector - Zones 1, 2 21, 22
Marechal SPeX ATEX Plug & Socket Power Connector - Zones 1, 2 21, 22
 
Thermon KSR-2 Heat Tracing Cable - Spec Sheet
Thermon KSR-2 Heat Tracing Cable - Spec SheetThermon KSR-2 Heat Tracing Cable - Spec Sheet
Thermon KSR-2 Heat Tracing Cable - Spec Sheet
 
Wolf Portable Lighting Catalogue - Torches, Head & Hand Lamps
Wolf Portable Lighting Catalogue - Torches, Head & Hand LampsWolf Portable Lighting Catalogue - Torches, Head & Hand Lamps
Wolf Portable Lighting Catalogue - Torches, Head & Hand Lamps
 
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting FEAM Lighting - Hazardous Area & Explosion Proof Lighting
FEAM Lighting - Hazardous Area & Explosion Proof Lighting
 
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous AreaStahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area
 
Explosion Proof Lights in Stock
Explosion Proof Lights in StockExplosion Proof Lights in Stock
Explosion Proof Lights in Stock
 
Stahl TEF 2430 Green Perimeter Light - ATEX Zone 1 Zone 2 Hazardous Area
Stahl TEF 2430 Green Perimeter Light - ATEX Zone 1 Zone 2 Hazardous AreaStahl TEF 2430 Green Perimeter Light - ATEX Zone 1 Zone 2 Hazardous Area
Stahl TEF 2430 Green Perimeter Light - ATEX Zone 1 Zone 2 Hazardous Area
 
Hadar - Hadar Lighting For Hazardous Areas (Zone 1 & Zone 2 - ATEX Certified)
Hadar - Hadar Lighting For Hazardous Areas (Zone 1 & Zone 2 - ATEX Certified)Hadar - Hadar Lighting For Hazardous Areas (Zone 1 & Zone 2 - ATEX Certified)
Hadar - Hadar Lighting For Hazardous Areas (Zone 1 & Zone 2 - ATEX Certified)
 
Marechal DXN ATEX Plug & Socket Outlets (Decontactors) for Hazardous Areas Zo...
Marechal DXN ATEX Plug & Socket Outlets (Decontactors) for Hazardous Areas Zo...Marechal DXN ATEX Plug & Socket Outlets (Decontactors) for Hazardous Areas Zo...
Marechal DXN ATEX Plug & Socket Outlets (Decontactors) for Hazardous Areas Zo...
 
Lucy Lighting Street Lighting Electrical Catalogue
Lucy Lighting Street Lighting Electrical CatalogueLucy Lighting Street Lighting Electrical Catalogue
Lucy Lighting Street Lighting Electrical Catalogue
 

Ähnlich wie Floodlights Zone 1 & Zone 2 (ATEX) - Hadar Hazardous Area Lighting

Wolf Safety Lamp - Zone 1 Hazardous Area Tank Lighting Kit (ATEX Certified)
Wolf Safety Lamp - Zone 1 Hazardous Area Tank Lighting Kit (ATEX Certified)Wolf Safety Lamp - Zone 1 Hazardous Area Tank Lighting Kit (ATEX Certified)
Wolf Safety Lamp - Zone 1 Hazardous Area Tank Lighting Kit (ATEX Certified)Thorne & Derrick International
 
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108 (36 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108 (36 Watts)Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108 (36 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108 (36 Watts)Thorne & Derrick International
 
Hadar HDL220 Zone 1 & Zone 21 Fluorescent Luminaire - Ex emb Fluorescent Li...
Hadar HDL220  Zone 1 & Zone 21 Fluorescent Luminaire  - Ex emb Fluorescent Li...Hadar HDL220  Zone 1 & Zone 21 Fluorescent Luminaire  - Ex emb Fluorescent Li...
Hadar HDL220 Zone 1 & Zone 21 Fluorescent Luminaire - Ex emb Fluorescent Li...Thorne & Derrick International
 
Nexans Euromold 675LR Dead Break Connectors 1250A 11kV 50-800sqmm
Nexans Euromold 675LR Dead Break Connectors 1250A 11kV 50-800sqmmNexans Euromold 675LR Dead Break Connectors 1250A 11kV 50-800sqmm
Nexans Euromold 675LR Dead Break Connectors 1250A 11kV 50-800sqmmThorne & Derrick International
 
Nexans Euromold K650LR Dead Break Connectors 800A 24kV 35-630sqmm
Nexans Euromold K650LR Dead Break Connectors 800A 24kV 35-630sqmmNexans Euromold K650LR Dead Break Connectors 800A 24kV 35-630sqmm
Nexans Euromold K650LR Dead Break Connectors 800A 24kV 35-630sqmmThorne & Derrick International
 
Nexans Euromold Connectors - 650LR 675LR Dead Break Tee Connectors (Interface D)
Nexans Euromold Connectors - 650LR 675LR Dead Break Tee Connectors (Interface D)Nexans Euromold Connectors - 650LR 675LR Dead Break Tee Connectors (Interface D)
Nexans Euromold Connectors - 650LR 675LR Dead Break Tee Connectors (Interface D)Thorne & Derrick International
 
Nexans Euromold 650LR Dead Break Connectors 800A 11kV 35-630sqmm
Nexans Euromold 650LR Dead Break Connectors 800A 11kV 35-630sqmmNexans Euromold 650LR Dead Break Connectors 800A 11kV 35-630sqmm
Nexans Euromold 650LR Dead Break Connectors 800A 11kV 35-630sqmmThorne & Derrick International
 
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingStahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingThorne & Derrick International
 
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingStahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingThorne & Derrick International
 
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingStahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingThorne & Derrick International
 
Hadar HDL133 Zone 1 ATEX Wellglass (55W - 85W) Hazardous Area Lighting
Hadar HDL133 Zone 1 ATEX Wellglass (55W - 85W) Hazardous Area LightingHadar HDL133 Zone 1 ATEX Wellglass (55W - 85W) Hazardous Area Lighting
Hadar HDL133 Zone 1 ATEX Wellglass (55W - 85W) Hazardous Area LightingThorne & Derrick International
 
Wellglass Lighting Zone 1 (ATEX) Ex ed or Ex de - Hadar Hazardous Area Lighting
Wellglass Lighting Zone 1 (ATEX) Ex ed or Ex de - Hadar Hazardous Area LightingWellglass Lighting Zone 1 (ATEX) Ex ed or Ex de - Hadar Hazardous Area Lighting
Wellglass Lighting Zone 1 (ATEX) Ex ed or Ex de - Hadar Hazardous Area LightingThorne & Derrick International
 
Hadar HDL134 Zone 1 ATEX Wellglass (165W) Hazardous Area Lighting
Hadar HDL134 Zone 1 ATEX Wellglass (165W) Hazardous Area LightingHadar HDL134 Zone 1 ATEX Wellglass (165W) Hazardous Area Lighting
Hadar HDL134 Zone 1 ATEX Wellglass (165W) Hazardous Area LightingThorne & Derrick International
 
Hadar HDL114 Zone 1 ATEX Wellglass (150W - 400W) Hazardous Area Lighting
Hadar HDL114 Zone 1 ATEX Wellglass (150W - 400W) Hazardous Area LightingHadar HDL114 Zone 1 ATEX Wellglass (150W - 400W) Hazardous Area Lighting
Hadar HDL114 Zone 1 ATEX Wellglass (150W - 400W) Hazardous Area LightingThorne & Derrick International
 
Walsall - Hazardous Area ATEX Manual Call Points & Breakglass Units Zone 1 & ...
Walsall - Hazardous Area ATEX Manual Call Points & Breakglass Units Zone 1 & ...Walsall - Hazardous Area ATEX Manual Call Points & Breakglass Units Zone 1 & ...
Walsall - Hazardous Area ATEX Manual Call Points & Breakglass Units Zone 1 & ...Thorne & Derrick International
 
Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT500 - 500W...
Zone 2  Flood Lights Atex Certified for Hazardous Areas - Petrel ZT500 - 500W...Zone 2  Flood Lights Atex Certified for Hazardous Areas - Petrel ZT500 - 500W...
Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT500 - 500W...Thorne & Derrick International
 
Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT400 - 400W ...
Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT400 - 400W ...Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT400 - 400W ...
Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT400 - 400W ...Thorne & Derrick International
 
Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT250 - 250W ...
Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT250 - 250W ...Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT250 - 250W ...
Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT250 - 250W ...Thorne & Derrick International
 
Hadar HDL233 Zone 2 ATEX Wellglass (55W - 85W) Hazardous Area Lighting
Hadar HDL233 Zone 2 ATEX Wellglass (55W - 85W) Hazardous Area LightingHadar HDL233 Zone 2 ATEX Wellglass (55W - 85W) Hazardous Area Lighting
Hadar HDL233 Zone 2 ATEX Wellglass (55W - 85W) Hazardous Area LightingThorne & Derrick International
 

Ähnlich wie Floodlights Zone 1 & Zone 2 (ATEX) - Hadar Hazardous Area Lighting (20)

Wolf Safety Lamp - Zone 1 Hazardous Area Tank Lighting Kit (ATEX Certified)
Wolf Safety Lamp - Zone 1 Hazardous Area Tank Lighting Kit (ATEX Certified)Wolf Safety Lamp - Zone 1 Hazardous Area Tank Lighting Kit (ATEX Certified)
Wolf Safety Lamp - Zone 1 Hazardous Area Tank Lighting Kit (ATEX Certified)
 
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108 (36 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108 (36 Watts)Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108 (36 Watts)
Zone 1 (ATEX) Bulkhead Fluorescent Fire Exit Luminaire - HDL108 (36 Watts)
 
Hadar HDL220 Zone 1 & Zone 21 Fluorescent Luminaire - Ex emb Fluorescent Li...
Hadar HDL220  Zone 1 & Zone 21 Fluorescent Luminaire  - Ex emb Fluorescent Li...Hadar HDL220  Zone 1 & Zone 21 Fluorescent Luminaire  - Ex emb Fluorescent Li...
Hadar HDL220 Zone 1 & Zone 21 Fluorescent Luminaire - Ex emb Fluorescent Li...
 
Nexans Euromold 675LR Dead Break Connectors 1250A 11kV 50-800sqmm
Nexans Euromold 675LR Dead Break Connectors 1250A 11kV 50-800sqmmNexans Euromold 675LR Dead Break Connectors 1250A 11kV 50-800sqmm
Nexans Euromold 675LR Dead Break Connectors 1250A 11kV 50-800sqmm
 
Nexans Euromold K650LR Dead Break Connectors 800A 24kV 35-630sqmm
Nexans Euromold K650LR Dead Break Connectors 800A 24kV 35-630sqmmNexans Euromold K650LR Dead Break Connectors 800A 24kV 35-630sqmm
Nexans Euromold K650LR Dead Break Connectors 800A 24kV 35-630sqmm
 
Nexans Euromold Connectors - 650LR 675LR Dead Break Tee Connectors (Interface D)
Nexans Euromold Connectors - 650LR 675LR Dead Break Tee Connectors (Interface D)Nexans Euromold Connectors - 650LR 675LR Dead Break Tee Connectors (Interface D)
Nexans Euromold Connectors - 650LR 675LR Dead Break Tee Connectors (Interface D)
 
Nexans Euromold 650LR Dead Break Connectors 800A 11kV 35-630sqmm
Nexans Euromold 650LR Dead Break Connectors 800A 11kV 35-630sqmmNexans Euromold 650LR Dead Break Connectors 800A 11kV 35-630sqmm
Nexans Euromold 650LR Dead Break Connectors 800A 11kV 35-630sqmm
 
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingStahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
 
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingStahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
 
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingStahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
 
JAREL EXPORT
JAREL EXPORTJAREL EXPORT
JAREL EXPORT
 
Hadar HDL133 Zone 1 ATEX Wellglass (55W - 85W) Hazardous Area Lighting
Hadar HDL133 Zone 1 ATEX Wellglass (55W - 85W) Hazardous Area LightingHadar HDL133 Zone 1 ATEX Wellglass (55W - 85W) Hazardous Area Lighting
Hadar HDL133 Zone 1 ATEX Wellglass (55W - 85W) Hazardous Area Lighting
 
Wellglass Lighting Zone 1 (ATEX) Ex ed or Ex de - Hadar Hazardous Area Lighting
Wellglass Lighting Zone 1 (ATEX) Ex ed or Ex de - Hadar Hazardous Area LightingWellglass Lighting Zone 1 (ATEX) Ex ed or Ex de - Hadar Hazardous Area Lighting
Wellglass Lighting Zone 1 (ATEX) Ex ed or Ex de - Hadar Hazardous Area Lighting
 
Hadar HDL134 Zone 1 ATEX Wellglass (165W) Hazardous Area Lighting
Hadar HDL134 Zone 1 ATEX Wellglass (165W) Hazardous Area LightingHadar HDL134 Zone 1 ATEX Wellglass (165W) Hazardous Area Lighting
Hadar HDL134 Zone 1 ATEX Wellglass (165W) Hazardous Area Lighting
 
Hadar HDL114 Zone 1 ATEX Wellglass (150W - 400W) Hazardous Area Lighting
Hadar HDL114 Zone 1 ATEX Wellglass (150W - 400W) Hazardous Area LightingHadar HDL114 Zone 1 ATEX Wellglass (150W - 400W) Hazardous Area Lighting
Hadar HDL114 Zone 1 ATEX Wellglass (150W - 400W) Hazardous Area Lighting
 
Walsall - Hazardous Area ATEX Manual Call Points & Breakglass Units Zone 1 & ...
Walsall - Hazardous Area ATEX Manual Call Points & Breakglass Units Zone 1 & ...Walsall - Hazardous Area ATEX Manual Call Points & Breakglass Units Zone 1 & ...
Walsall - Hazardous Area ATEX Manual Call Points & Breakglass Units Zone 1 & ...
 
Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT500 - 500W...
Zone 2  Flood Lights Atex Certified for Hazardous Areas - Petrel ZT500 - 500W...Zone 2  Flood Lights Atex Certified for Hazardous Areas - Petrel ZT500 - 500W...
Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT500 - 500W...
 
Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT400 - 400W ...
Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT400 - 400W ...Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT400 - 400W ...
Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT400 - 400W ...
 
Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT250 - 250W ...
Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT250 - 250W ...Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT250 - 250W ...
Zone 2 Flood Lights Atex Certified for Hazardous Areas - Petrel ZT250 - 250W ...
 
Hadar HDL233 Zone 2 ATEX Wellglass (55W - 85W) Hazardous Area Lighting
Hadar HDL233 Zone 2 ATEX Wellglass (55W - 85W) Hazardous Area LightingHadar HDL233 Zone 2 ATEX Wellglass (55W - 85W) Hazardous Area Lighting
Hadar HDL233 Zone 2 ATEX Wellglass (55W - 85W) Hazardous Area Lighting
 

Mehr von Thorne & Derrick International

Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Thorne & Derrick International
 
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptTHORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptThorne & Derrick International
 
The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018Thorne & Derrick International
 
3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick InternationalThorne & Derrick International
 
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-AThorne & Derrick International
 
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...Thorne & Derrick International
 
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Thorne & Derrick International
 
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RowePepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RoweThorne & Derrick International
 
Ultrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandUltrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandThorne & Derrick International
 
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DSIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DThorne & Derrick International
 
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...Thorne & Derrick International
 
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetFiloform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetThorne & Derrick International
 

Mehr von Thorne & Derrick International (20)

Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...
 
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptTHORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
 
The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018
 
3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International
 
CATU Electrical Safety Catalogue
CATU Electrical Safety CatalogueCATU Electrical Safety Catalogue
CATU Electrical Safety Catalogue
 
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
 
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
 
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
 
Roxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional DrawingRoxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional Drawing
 
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RowePepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
 
T&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive AtmospheresT&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive Atmospheres
 
Ultrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandUltrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification Demand
 
Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016
 
Thorne & Derrick Process Heating Brochure 2016
Thorne & Derrick Process Heating Brochure 2016Thorne & Derrick Process Heating Brochure 2016
Thorne & Derrick Process Heating Brochure 2016
 
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DSIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
 
Ripley Utility Tool Cable Preparation Tools
Ripley Utility Tool Cable Preparation ToolsRipley Utility Tool Cable Preparation Tools
Ripley Utility Tool Cable Preparation Tools
 
RIDGID micro CD100 Combustible Gas Detector
RIDGID micro CD100 Combustible Gas DetectorRIDGID micro CD100 Combustible Gas Detector
RIDGID micro CD100 Combustible Gas Detector
 
Itron Fact Sheet
Itron Fact SheetItron Fact Sheet
Itron Fact Sheet
 
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
 
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetFiloform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
 

Kürzlich hochgeladen

The State of Passkeys with FIDO Alliance.pptx
The State of Passkeys with FIDO Alliance.pptxThe State of Passkeys with FIDO Alliance.pptx
The State of Passkeys with FIDO Alliance.pptxLoriGlavin3
 
React Native vs Ionic - The Best Mobile App Framework
React Native vs Ionic - The Best Mobile App FrameworkReact Native vs Ionic - The Best Mobile App Framework
React Native vs Ionic - The Best Mobile App FrameworkPixlogix Infotech
 
The Future Roadmap for the Composable Data Stack - Wes McKinney - Data Counci...
The Future Roadmap for the Composable Data Stack - Wes McKinney - Data Counci...The Future Roadmap for the Composable Data Stack - Wes McKinney - Data Counci...
The Future Roadmap for the Composable Data Stack - Wes McKinney - Data Counci...Wes McKinney
 
Data governance with Unity Catalog Presentation
Data governance with Unity Catalog PresentationData governance with Unity Catalog Presentation
Data governance with Unity Catalog PresentationKnoldus Inc.
 
Moving Beyond Passwords: FIDO Paris Seminar.pdf
Moving Beyond Passwords: FIDO Paris Seminar.pdfMoving Beyond Passwords: FIDO Paris Seminar.pdf
Moving Beyond Passwords: FIDO Paris Seminar.pdfLoriGlavin3
 
Time Series Foundation Models - current state and future directions
Time Series Foundation Models - current state and future directionsTime Series Foundation Models - current state and future directions
Time Series Foundation Models - current state and future directionsNathaniel Shimoni
 
Testing tools and AI - ideas what to try with some tool examples
Testing tools and AI - ideas what to try with some tool examplesTesting tools and AI - ideas what to try with some tool examples
Testing tools and AI - ideas what to try with some tool examplesKari Kakkonen
 
Modern Roaming for Notes and Nomad – Cheaper Faster Better Stronger
Modern Roaming for Notes and Nomad – Cheaper Faster Better StrongerModern Roaming for Notes and Nomad – Cheaper Faster Better Stronger
Modern Roaming for Notes and Nomad – Cheaper Faster Better Strongerpanagenda
 
Transcript: New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024Transcript: New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024BookNet Canada
 
2024 April Patch Tuesday
2024 April Patch Tuesday2024 April Patch Tuesday
2024 April Patch TuesdayIvanti
 
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptxThe Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptxLoriGlavin3
 
Top 10 Hubspot Development Companies in 2024
Top 10 Hubspot Development Companies in 2024Top 10 Hubspot Development Companies in 2024
Top 10 Hubspot Development Companies in 2024TopCSSGallery
 
Genislab builds better products and faster go-to-market with Lean project man...
Genislab builds better products and faster go-to-market with Lean project man...Genislab builds better products and faster go-to-market with Lean project man...
Genislab builds better products and faster go-to-market with Lean project man...Farhan Tariq
 
Arizona Broadband Policy Past, Present, and Future Presentation 3/25/24
Arizona Broadband Policy Past, Present, and Future Presentation 3/25/24Arizona Broadband Policy Past, Present, and Future Presentation 3/25/24
Arizona Broadband Policy Past, Present, and Future Presentation 3/25/24Mark Goldstein
 
Bridging Between CAD & GIS: 6 Ways to Automate Your Data Integration
Bridging Between CAD & GIS:  6 Ways to Automate Your Data IntegrationBridging Between CAD & GIS:  6 Ways to Automate Your Data Integration
Bridging Between CAD & GIS: 6 Ways to Automate Your Data Integrationmarketing932765
 
How AI, OpenAI, and ChatGPT impact business and software.
How AI, OpenAI, and ChatGPT impact business and software.How AI, OpenAI, and ChatGPT impact business and software.
How AI, OpenAI, and ChatGPT impact business and software.Curtis Poe
 
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptx
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptxMerck Moving Beyond Passwords: FIDO Paris Seminar.pptx
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptxLoriGlavin3
 
TrustArc Webinar - How to Build Consumer Trust Through Data Privacy
TrustArc Webinar - How to Build Consumer Trust Through Data PrivacyTrustArc Webinar - How to Build Consumer Trust Through Data Privacy
TrustArc Webinar - How to Build Consumer Trust Through Data PrivacyTrustArc
 
A Framework for Development in the AI Age
A Framework for Development in the AI AgeA Framework for Development in the AI Age
A Framework for Development in the AI AgeCprime
 
Emixa Mendix Meetup 11 April 2024 about Mendix Native development
Emixa Mendix Meetup 11 April 2024 about Mendix Native developmentEmixa Mendix Meetup 11 April 2024 about Mendix Native development
Emixa Mendix Meetup 11 April 2024 about Mendix Native developmentPim van der Noll
 

Kürzlich hochgeladen (20)

The State of Passkeys with FIDO Alliance.pptx
The State of Passkeys with FIDO Alliance.pptxThe State of Passkeys with FIDO Alliance.pptx
The State of Passkeys with FIDO Alliance.pptx
 
React Native vs Ionic - The Best Mobile App Framework
React Native vs Ionic - The Best Mobile App FrameworkReact Native vs Ionic - The Best Mobile App Framework
React Native vs Ionic - The Best Mobile App Framework
 
The Future Roadmap for the Composable Data Stack - Wes McKinney - Data Counci...
The Future Roadmap for the Composable Data Stack - Wes McKinney - Data Counci...The Future Roadmap for the Composable Data Stack - Wes McKinney - Data Counci...
The Future Roadmap for the Composable Data Stack - Wes McKinney - Data Counci...
 
Data governance with Unity Catalog Presentation
Data governance with Unity Catalog PresentationData governance with Unity Catalog Presentation
Data governance with Unity Catalog Presentation
 
Moving Beyond Passwords: FIDO Paris Seminar.pdf
Moving Beyond Passwords: FIDO Paris Seminar.pdfMoving Beyond Passwords: FIDO Paris Seminar.pdf
Moving Beyond Passwords: FIDO Paris Seminar.pdf
 
Time Series Foundation Models - current state and future directions
Time Series Foundation Models - current state and future directionsTime Series Foundation Models - current state and future directions
Time Series Foundation Models - current state and future directions
 
Testing tools and AI - ideas what to try with some tool examples
Testing tools and AI - ideas what to try with some tool examplesTesting tools and AI - ideas what to try with some tool examples
Testing tools and AI - ideas what to try with some tool examples
 
Modern Roaming for Notes and Nomad – Cheaper Faster Better Stronger
Modern Roaming for Notes and Nomad – Cheaper Faster Better StrongerModern Roaming for Notes and Nomad – Cheaper Faster Better Stronger
Modern Roaming for Notes and Nomad – Cheaper Faster Better Stronger
 
Transcript: New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024Transcript: New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
 
2024 April Patch Tuesday
2024 April Patch Tuesday2024 April Patch Tuesday
2024 April Patch Tuesday
 
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptxThe Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
 
Top 10 Hubspot Development Companies in 2024
Top 10 Hubspot Development Companies in 2024Top 10 Hubspot Development Companies in 2024
Top 10 Hubspot Development Companies in 2024
 
Genislab builds better products and faster go-to-market with Lean project man...
Genislab builds better products and faster go-to-market with Lean project man...Genislab builds better products and faster go-to-market with Lean project man...
Genislab builds better products and faster go-to-market with Lean project man...
 
Arizona Broadband Policy Past, Present, and Future Presentation 3/25/24
Arizona Broadband Policy Past, Present, and Future Presentation 3/25/24Arizona Broadband Policy Past, Present, and Future Presentation 3/25/24
Arizona Broadband Policy Past, Present, and Future Presentation 3/25/24
 
Bridging Between CAD & GIS: 6 Ways to Automate Your Data Integration
Bridging Between CAD & GIS:  6 Ways to Automate Your Data IntegrationBridging Between CAD & GIS:  6 Ways to Automate Your Data Integration
Bridging Between CAD & GIS: 6 Ways to Automate Your Data Integration
 
How AI, OpenAI, and ChatGPT impact business and software.
How AI, OpenAI, and ChatGPT impact business and software.How AI, OpenAI, and ChatGPT impact business and software.
How AI, OpenAI, and ChatGPT impact business and software.
 
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptx
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptxMerck Moving Beyond Passwords: FIDO Paris Seminar.pptx
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptx
 
TrustArc Webinar - How to Build Consumer Trust Through Data Privacy
TrustArc Webinar - How to Build Consumer Trust Through Data PrivacyTrustArc Webinar - How to Build Consumer Trust Through Data Privacy
TrustArc Webinar - How to Build Consumer Trust Through Data Privacy
 
A Framework for Development in the AI Age
A Framework for Development in the AI AgeA Framework for Development in the AI Age
A Framework for Development in the AI Age
 
Emixa Mendix Meetup 11 April 2024 about Mendix Native development
Emixa Mendix Meetup 11 April 2024 about Mendix Native developmentEmixa Mendix Meetup 11 April 2024 about Mendix Native development
Emixa Mendix Meetup 11 April 2024 about Mendix Native development
 

Floodlights Zone 1 & Zone 2 (ATEX) - Hadar Hazardous Area Lighting

  • 1. Hazardous Interim Cover.FH11 Sat Feb 07 11:04:56 2009 Page 2 Composite C M Y CM MY CY CMY K Engineering Solutions Design to Manufacture An A-Belco Group Company L I G H T I N GF O R H A Z A R D O U S A R E A S CABLE JOINTS, CABLE TERMINATIONS, CABLE GLANDS, CABLE CLEATS FEEDER PILLARS, FUSE LINKS, ARC FLASH, CABLE ROLLERS, CUT-OUTS 11KV 33KV CABLE JOINTS & CABLE TERMINATIONS FURSE EARTHING www.cablejoints.co.uk Thorne and Derrick UK Tel 0044 191 490 1547 Fax 0044 191 477 5371 Tel 0044 117 977 4647 Fax 0044 117 9775582
  • 2. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 1 Composite C M Y CM MY CY CMY K The Hadar Lighting Range Designed and manufactured in the UK by A-Belco Hazardous Area, the portfolio of products comprises: Fluorescent Recessed Portable Bulkhead Wellglass Floodlight LED Suitable for use in any environment where an explosive atmosphere may exist, the range of luminaires within the Hadar Lighting portfolio are certified to Zone 1, Ex e, Ex d, and Zone 2 Ex n. Launched in 2005, a high degree of engineering expertise, project knowledge, experience and investment in the Hadar Lighting range is reflected through the high specification construction of the luminaires. The innovative, modular and low maintenance designs incorporate the latest technologies, ensuring a comprehensive lighting product offering. The Ex e products feature the "End of Life" (EoL) protection circuit ballast according to DIN EN 61347-2-3 and IEC 60079-7 Ed.4. Working alongside our network of UK and global distributors and partners in Australia, Singapore and Malaysia, USA and UAE, we offer competitive export bid packages for a wide range of projects. From design to manufacture, we excel in quality, price, delivery and after sales support.
  • 3. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 2 Composite C M Y CM MY CY CMY K LIGHTING RANGE Zone 1 HDL 100 Fluorescent 2 HDL 102 Recessed 4 HDL 103G Helideck Luminaire 6 HDL 103R Obstruction Luminaire 6 HDL 103W Bulkhead Luminaire 6 HDL 105 Portable 8 HDL 105T Transformer 10 CTB Junction Box 11 HDL 106 LED Floodlight 12 HDL 108 Bulkhead (metal) 14 HDL 109 Bulkhead (plastic) 16 HDL 113 Small Wellglass 18 HDL 114 Large Wellglass 18 HDL 133 Small QL Wellglass 18 HDL 134 Large QL Wellglass 18 HDL 117 Floodlight 20 Zone 2 HDL 220 Fluorescent 22 HDL 223 Small Wellglass 24 HDL 224 Large Wellglass 24 HDL 233 Small QL Wellglass 24 HDL 234 Large QL Wellglass 24 HDL 227 Floodlight 26
  • 4. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 3 Composite C M Y CM MY CY CMY K Simple installation. Straightforward maintenance. Pole mount option. Emergency version available. Rugged construction. Easily relamped with detachable lamp envelope. Mains isolation not required when relamping. Short gaskets for proven ingress protection. Mounting in any attitude. Features a reflector compatible with Unistrut channel support systems and accessories. Pole Mount available. Continuous monitoring of fluorescent lamps ensures safe end of life shutdown by electronic ballast in accordance with HSE safety notice 8/05. Overvoltage protection 320V for 1 minute. Electronic control gear for instant operation and reduced running costs. High frequency electronic ballast suitable for operation at lower temperatures. EMERGENCY VERSION Standard emergency - one fluorescent lamp remains at a reduced output. Can be operated maintained or non maintained. HADAR LIGHTING Zone 1 Ex em FLUORESCENT LUMINAIRE - HDL 100 KEY FEATURES - Zone 1 Ex em Fluorescent Luminaire 2 SPECIFICATION Enclosure Polycarbonate Lamp Envelope Polycarbonate Reflector Aluminium Powder Coated Gaskets Silicone External Fasteners A4 Stainless Steel T Rating T4/T5 Gas and Dust Surface Temp 100ºC 2 x 18W / 36W -30ºC to +55ºC T4 -30ºC to +32ºC T5 2 x 58W -30ºC to +53ºC T4 Emergency Range -15ºC DIMENSIONS PROTECTION II 2GD Ex emb II T4/T5 IP66/67 Ex tD A21 T100ºC Incorporates the new “End of Life” (EoL) protection circuit ballast - according to DIN EN 61347-2-3 and IEC 60079-7 Ed.4 Annex H CERTIFICATION ATEX & IEC Ex CERTIFIED BY SIRA; ABS APPROVED FOR MARINE USE Certification Ambient Certificate HDL 100 II 2GD Ex emb II T4/T5 IP66/67 IEC Ex SIR 06.0026X SIRA 06 ATEX 3079X ABS 07-LD219463-PDA Voltage Range 110V to 254V 2 x 18W 2 X 36W 2 X 58W 970mm 1580mm 1880mm A Weight 4kg 5.8kg 6.8kg
  • 5. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 4 Composite C M Y CM MY CY CMY K 3 2 x 18W 32W circuit watts at 240V - 0.14A (120V - 0.28A) Better 220V - 254V, 47/63 Hz AC/DC 2 x 36W 62W circuit watts at 240V - 0.27A (120V - 0.54A) Than 110V - 130V, 47/63 Hz AC/DC (2 x 18W/2 x 36W only) 2 x 58W 92W circuit watts at 240V - 0.40A (120V - 0.80A) 0.95 Emergency version as above - AC only ELECTRICAL SPECIFICATIONS Lamp Options Power consumption Power factor Power supply Electrical Specification HADAR LIGHTING Zone 1 Ex em FLUORESCENT LUMINAIRE - HDL 100 Product HDL100 S - Non Emergency E - Emergency L - Loop In / Loop Out P - Pole Mount H - High Voltage (220V - 254V) M - Medium Voltage (110V - 130V) 0 - M20 entries 5 - M25 entries 218 - 2 x 18W Lamp Options 236 - 2 x 36W 258 - 2 x 58W ORDERING MATRIX Field Options Fittings Voltage Cable Entries Up to 6mm2 clamp terminals for live, live switched, neutral, earth and looping are provided. Internal and external earth as standard. Screw terminals upon request. Installation document AL10086 supplied. 2 x M20. Pole mount fittings supplied with 1 x M20 (other entries upon request). INSTALLATION Terminals Cable Entries The aluminium reflector incorporates a channel which is compatible with Unistrut (or equivalent) fixings and accessories and allows the installer to select variable fixing centres. Technical Booklet with various mounting options available upon request. Suspension Installation 1) Final Product Code should be in the format: HDL100SPH0218 2) Bi-Pin as standard. Contact sales office for Single Pin. 3) For Photometric Data contact the sales office. 4) Brass earth continuity gland plates are available, contact sales office for more information. Notes Version
  • 6. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 5 Composite C M Y CM MY CY CMY K DIMENSIONS FOR NON MODULAR RANGE OF RECESSIBLES FOR MODULAR RANGE DIMENSIONS CONTACT THE SALES DEPT Exposed ‘T’/Concealed ‘T’ Modular ceiling type. Plasterboard Non-modular Ceiling type. Plank Ceiling type 300mm wide. Mild Steel painted as standard (Stainless steel also available). 2 x 18 W, 4 x 18W, 2 x 36W, 4 x 36W, 2 x 58W. Emergency version available. For 2 x 18W Compact Fluorescent Luminaire see - HDL 108. Ease of maintenance and installation. Wide range of lamp options. High frequency electronic control gear. Quick lamp start and flicker free operation control gear. High ambient areas. Can be installed in new or existing ceilings. Lightweight and robust construction. Cable entries can be positioned to suit customer requirements. Overvoltage protection 320V for 1 minute. Standard/Emergency gear trays interchangeable between luminaires. Continuous monitoring of fluorescent lamps ensures safe end of life shutdown. by electronic ballast in accordance with HSE safety notice 8/05. Optional mains isolation/battery isolation microswitch available. EMERGENCY VERSION Emergency version as above - AC only. HADAR LIGHTING Zone 1 Ex em RECESSED LUMINAIRE - HDL 102 KEY FEATURES - Zone 1 Ex em Recessed Luminaire 4 SPECIFICATION Enclosure Steel Powder Coated Diffuser Frame or Stainless Steel Diffuser Toughened Prismatic Glass Gasket Silicone External Fasteners A4 Stainless Steel T Rating T4/T5 Gas and Dust Surface Temp 75ºC All ranges T4 -40ºC to +55ºC All ranges T5 -40ºC to +40ºC Emergency Range -15ºC DIMENSIONS PROTECTION II 2GD Ex emb II T4/T5 IP64 Ex tD A21 T75ºC CERTIFICATION ATEX & IEC Ex CERTIFIED BY SIRA Certification Ambient Certificate HDL 102 II 2GD Ex emb II T4/T5 IP64 IEC Ex SIR 06.0027 SIRA 06 ATEX 3080 Voltage Range 110V - 254V 2 x 18W 2 x 36W 2 x 58W 4 x 18W 4 x 36W A Weight Incorporates the new “End of Life” (EoL) protection circuit ballast - according to DIN EN 61347-2-3 and IEC 60079-7 Ed 4 Annex H B 10kg 16kg 18kg 15kg 18kg 700mm 1310mm 1610mm 700mm 1310mm 299mm 299mm 299mm 599mm 599mm
  • 7. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 6 Composite C M Y CM MY CY CMY K 1) Final Product Code should be in the format: HDL102SCH0218 2) Bi-Pin as standard. Contact sales office for single pin. 3) Mild Steel as standard, contact sales office for stainless steel. 4) For Photometric data contact the sales office. 5 2 x 18W T8 32W circuit watts at 240V - 0.14A (120V - 0.28A) 2 x 36W T8 62W circuit watts at 240V - 0.27A (120V - 0.28A) Better 220V - 254V, 47/63 Hz AC/DC 2 x 58W T8 92W circuit watts at 240V - 0.40A (120V - 0.80A) Than 110V - 130V, 47/63 Hz AC/DC (18W/36W only) 4 x 18W T8 64W circuit watts at 240V - 0.28A (120V - 0.56A) 0.95 Emergency version as above - AC only 4 x 36W T8 124W circuit watts at 240V - 0.54A (120V - 1.08A) ELECTRICAL SPECIFICATIONS Lamp Options Power consumption Power factor Power supply Electrical Specification HADAR LIGHTING Zone 1 Ex em RECESSED LUMINAIRE - HDL 102 HDL102 S - Non Emergency E - Emergency A - Exposed ‘T’ B - Concealed ‘T’ C - Non Modular D - Plank H - High Voltage (220V - 254V) M - Medium Voltage (110V - 130V) 0 - M20 Entries 5 - M25 Entries 218 - 2 x 18W 236 - 2 x 36W 258 - 2 x 58W 418 - 4 x 18W 436 - 4 x 36W ORDERING MATRIX Field Options Fittings Voltage Cable Entries Up to 6mm2 clamp terminals for live, live switched, neutral, earth and looping are provided. Internal and external earth as standard. Screw terminals upon request. Installation document AL10089 supplied. To suit individual customer requirements. INSTALLATION Terminals Cable Entries To suit individual customer requirements.Suspension Installation Notes Product Version Lamp Options
  • 8. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 7 Composite C M Y CM MY CY CMY K HADAR LIGHTING Zone 1 LED HELIDECK/OBSTRUCTION/BULKHEAD LUMINAIRE - HDL 103 6 Available in Green (Helidecks), Red (Obstruction) or White (general lighting). Customer can select constant light output or flashing upon installation. Conforms to ICAO annex 14 volume II and CAP437 for helideck perimeter lighting. LED technology will give a predicted working life of 10 years +. Utilises 6 off 1.2W LEDs. Low power consumption. Easy installation and low maintenance. Rugged construction - resistant to vibration. Instant light output. 360º coverage. Independently photometrically tested. All units supplied with 3 cable entries. IP66 and IP67. Optional wire guard available for extra protection. KEY FEATURES - LED Helideck/Obstruction/Bulkhead Luminaire/Zone 1 Ex em All variants -30ºC to +55ºC DIMENSIONS PROTECTION II 2GD Ex emb II T4/T5/T6 IP66/67, Ex tD A21 T100ºC CERTIFICATION ATEX & IEC Ex PENDING BY SIRA Certification Ambient Certificate HDL103 II 2GD Ex emb II T4/T5/T6 IP66/67 ATEX and IEC Ex pending Voltage Range 110V to 254V SPECIFICATION Main Body Marine Grade Aluminium Clear Lens Polycarbonate Gaskets Silicone/Rubber External Fasteners A4 Stainless Steel T Rating T4/T5/T6 Surface Temp 100ºC Weight 3.0kg 124 CRS 124CRS 125 Ø200 4 FIXING HOLES Ø11
  • 9. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 8 Composite C M Y CM MY CY CMY K 7 HADAR LIGHTING Zone 1 LED HELIDECK/OBSTRUCTION/BULKHEAD LUMINAIRE - HDL 103 6 x 1.2W LED's ELECTRICAL SPECIFICATIONS Lamp Options Power consumption Power factor Power supply Electrical Specification HDL103 G - Green LED's R - Red LED's W - White LED's 0 - No wire guard 1 - Wire guard fitted 0 - M20 5 - M25 00 - Standard ORDERING MATRIX Field Options Up to 4mm 2 screwed terminals for live, neutral, earth and looping are provided. Internal and external earth as standard. Installation document AL10319 supplied. 3 x M20, one fitted with approved stopper plug, other entries available on request. INSTALLATION Terminals Cable Entries Via 4 external mounting points.Suspension Installation 1) Typical ordering reference HDL103G0000. 2) For Photometric Data contact the sales office. Notes Product Version Fittings 12W Max N/A 110V-254V 47/63Hz AC/DC Cable Entries Other Options
  • 10. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 9 Composite C M Y CM MY CY CMY K 2 x 18W, 2 x 36W, 2 x 58W, 4 x 18W, 4 x 36W and 4 x 58W Compact Fluorescent Lamp. 2 x 18W, 2 x 36W, 2 x 58W T8 Fluorescent Lamp, Bi Pin or Single Pin. Wide Voltage range (24V to 254V). Can be supplied with direct cable entries or fitted with plugs / sockets to allow luminaires to be instantly linked in series (plug and play). Emergency versions available for T8 lamp variant. IP68 rated. Aluminium or polycarbonate end caps. Rugged construction. Easily relamped - uses standard compact fluorescent lamp / T8 lamp. Short gaskets for proven ingress protection. Mounting in any attitude. Features mounting points compatible with Unistrut support systems and accessories. Can be supplied with pre-fitted cable, plug and mounted socket (eg. ATX, Stahl, Ceag). Hanging / Carrying strap supplied as standard. Continuous monitoring of fluorescent lamps ensures safe end of life shutdown by electronic ballast in accordance with HSE safety notice 8/05 Overvoltage protection 320V for 1 minute (110V and 240V only). Electronic control gear for instant operation and reduced running costs. High frequency electronic ballast suitable for operation at lower temperatures. Portable versions are supplied with an anti static protective coating. Industrial variant available. Can be supplied with SY, HOFR or ships cable. Available with a variety of accessories, mounting stands, tripods. Replaceable, protective films available for use in paint shop applications. KEY FEATURES - Zone 1 Ex em Portable Temporary Permanent Linkable Luminaire EMERGENCY VERSION Standard emergency - one fluorescent lamp remains at a reduced output Can be operated maintained or non maintained (T8 110V or 240V ac variants only). PROTECTION II 2GD Ex emb II T3/T4 IP66/67/68 (30 minutes at 3m depth) EEx tD A21 T100ºC SPECIFICATION End caps Polycarbonate or Aluminium Clear tube Polycarbonate Gasket Silicone External fasteners A4 Stainless steel T Rating T3/T4 Gas and Dust Surface Temperature 100ºC Incorporates the new "End of Life" (EoL) protection circuit ballast - according to DIN EN 61347-2-3 and IEC 60079-7 Ed.4 Annex H CERTIFICATION ATEX & IEC Ex CERTIFIED BY SIRA Certification Ambient Certificate HDL105 Cable Gland option II 2GD Ex emb II T3/T4 IP66/67/68 Plug and Socket option II 2GD Ex embd IIC T3/T4 IP66 IEC Ex SIR 07.0020 SIRA 07 ATEX 3032 Voltage Range 4 x CFL -20ºC to +35ºC T3 2 x CFL -20ºC to +44ºC T3 2 x T8 -20ºC to +53ºC T4 Emergency Range -15ºC to +53ºC T4 24V - 28V AC/DC 42V - 54V AC/DC 110V - 130V AC/DC 220V - 254V AC/DC 8 Magnetic fixing brackets allow ease of installation / removal to steel structures Stand attachment allows vertical orientation, ideal for maintenance requirements HADAR LIGHTING Zone 1 Ex em PORTABLE TEMPORARY PERMANENT LINKABLE LUMINAIRE - HDL 105
  • 11. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 10 Composite C M Y CM MY CY CMY K Up to 4mm2 screwed terminals for live, live switched, neutral, earth and looping are provided. Internal earth as standard. Installation document AL10171. Each aluminium or polycarbonate end cap incorporates 4 channels which are compatible with Unistrut (or equivalent) fixings and accessories supplied with suitable suspension / carrying strap M6 clearance holes allow mounting plates to be attached to provide free standing luminaires. Tri pod, floor stands and other various accessories are available. INSTALLATION Terminals Suspension / Mounting Installation 2) For Photometric Data contact the sales office 3) Cable entries - over 5000 combinations (M20/M25 entries, plug, socket and cable variants). Contact the technical department. 1) Typical ordering reference: HDL105SAL00218C Notes 2 x 18W 2 x 36W 2 x 55/58W 4 x 18W 4 x 36W 4 x 55W ELECTRICAL SPECIFICATIONS Lamp Options Typical power consumption Power factor Available power supplies Electrical Specification 32W 62W 92W 64W 124W 184W Better than 0.95 220V - 254V 47/63 Hz AC/DC (all variants) 110V - 130V 47/63 Hz AC/DC (18W & 36W only) 24V - 28V AC/DC (36W only) 42V - 54V AC/DC (36W only) HDL105 S - Standard E - Emergency A - Aluminium P - Polycarbonate H - High Voltage 220 - 254V M - Medium Voltage 110V - 130V L - Low Voltage 42V - 54V E - Extra Low Voltage 24V - 28V 00 - Refer to Notes 218 - 2 x 18W 236 - 2 x 36W 258 - 2 x 55/58W 418 - 4 x 18W 436 - 4 x 36W 458 - 4 x 55W C - Compact B - Bi Pin T8 S - Single Pin T8 ORDERING MATRIX Field 0ptions Voltage Cable Entries Product Version Lamp Options Lamp Type 9 HADAR LIGHTING Zone 1 Ex em PORTABLE TEMPORARY - PERMANENT LINKABLE LUMINAIRE - HDL105 End Caps DIMENSIONS 2 x 18W 399 2 x 36W 552 2 x 58W 676 4 x 18W 588 4 x 36W 782 4 x 58W 906 Lamp Typical length mm
  • 12. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 11 Composite C M Y CM MY CY CMY K 10 HADAR LIGHTING Zone 1 Ex ed TRANSFORMER - HDL 105T 316L stainless steel enclosure and skid. Feed through terminals. Input and output fuse holder. 400VA, 110V or 230V input, 24V or 48V output. Entry devices - 2 cable glands or input sockets / plugs. Output devices - 2 to 4 cable glands or output sockets / plugs. Comes mounted on a stainless steel skid. Related Lighting Product: HDL 105 Ex em Portable. KEY FEATURES - Ex ed Transformer SPECIFICATION Enclosure/Skid A4 Stainless Steel Gasket One Piece Polyurethane Operating Temperature -80°C to 100°C Door Fixings Hinged Removable Door with Captive Fastening Screws Earth Screws M10 Internal and External Brass Earth Stud Assembly M6 Stud on the Door DIMENSIONS PROTECTION II 2GD Ex ed IIC T4 IP66 -20°C to +40°C -20°C to +30°C CERTIFICATION ATEX approved by SIRA Certification Ambient Certificate HDL 105T 350VA: II 2GD Ex ed IIC T4 400VA: II 2GD Ex ed IIC T4 SIRA 07 ATEX 3277X Voltage Range 110V or 230V input 24V or 48V output HDL105T 11V - 110V 23V - 230V 5 - 50Hz 6 - 60Hz 00 - 4 x 16A socket outlets 01 - 2 x 16A socket outlets 00 - 2 x M20 clearance holes 01 - 1 x M20 clearance holes ORDERING MATRIX Field Options Frequency Voltage 1) Final Product Code should be in one format: HDL105T2350000. 2) For non-standard variations contact the sales office. Notes Product Outlet Options Inlet Options
  • 13. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 12 Composite C M Y CM MY CY CMY K CSTB121208-SS CSTB151509-SS CSTB191910-SS CTB221513 CTB262616 CTB262620 CTB303016 CTB303020 CTB382616 CTB382620 CTB453816 CTB453820 CTB484816 CTB484820 CTB503516 CTB503520 CTB624516 CTB624520 CTB745520 CTB765020 CTB866420 CTB916120 CTB987420 11 HADAR LIGHTING Zone 1 EEx e CTB JUNCTION BOX AISI 316L Stainless Steel. Used as increased safety and / or intrinsic safety enclosures in electrical systems. They can be supplied with or without terminals; with multiple boxes, modular terminals and drilled with holes according to customer specifications. CSTB – small terminal box with no gland plate option. Options include; Tag identification plates, Gland plates 1, 2, 3 and 4; Stopping plugs and Drain and breather valves. KEY FEATURES - EEx e - CTB -50°C to +40°C -50°C to +55°C -50°C to +55°C -50°C to +40°C -50°C to +55°C -50°C to +55°C -50°C to +40°C -50°C to +55°C -50°C to +55°C -50°C to +40°C -50°C to +55°C -50°C to +55°C CERTIFICATION ATEX approved by SIRA Certification Ambient Certificate Terminal Box SIRA 03 ATEX 3386 PROTECTION CE Ex II 2GD EEx e II EEx ia IIC T6/T5 IP66 Empty Box EEx e II T6 EEx e II T6 EEx e II T5 EEx ai IIC T6 EEx ai IIC T6 EEx ai IIC T5 EEx e II T6 EEx e II T6 EEx e II T5 EEx ai IIC T6 EEx ai IIC T6 EEx ai IIC T5 SIRA 03 ATEX 3397U SPECIFICATION Material Highly corrosion resistant 1.5/2.0mm stainless steel 316L or mild steel pregalvanised and painted RAL7015 1000 hours saltspray test Surface treatment: ultrasonic degreased and passivated Gasket One piece polyurethane gasket Operating temperature -80°C to 100°C Door Fixings Hinged removable door with captive fastening screws Box Mounting 4 x external lugs, 11mm diameter holes 4 x direct fixing holes (M6) on rear of box (no lugs required) Stud Assembly M6 Stud on the Door Internal Mounting 4 x stand off 14mm dia. Pillars 25mm high tapped M6 for Din rail or mounting plate installations Earth Screws M10 internal and external brass earth stud assembly with an M6 stud on the door Part Number Size mm L W H 120 150 190 229 260 260 300 306 380 380 458 458 480 480 500 500 620 620 740 762 860 914 980 120 150 190 150 260 260 300 306 260 260 382 382 480 480 350 350 450 450 550 508 640 610 740 80 90 100 130 160 205 160 205 160 205 160 205 160 205 160 205 160 205 205 205 205 205 205 DIMENSIONS
  • 14. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 13 Composite C M Y CM MY CY CMY K 12 HADAR LIGHTING Zone 1 MODULAR LED LUMINAIRE/FLOODLIGHT - HDL 106 Modular construction allows the modules to be interlinked with each other to provide greater light output. Can be used as a single unit - small floodlight or bulkhead or be linked together to replicate a large 250W/400W floodlight. Each module utilises 48 off 1.2W LEDs. Integrated power supply. Low power consumption. Rugged construction - resistant to vibration. Independently photometrically tested. All units supplied with 2 cable entries. IP66 and IP67. Optional wire guard available for extra protection. Infra red variants available. Wide, medium and narrow beam light output available. In comparison to typical Ex d floodlights - 60% less weight. 50% less power consumption. One man installation. LED technology will give a predicted Lamp life of 10 years+. No light pollution. Instant restrike. No light degradation at low temperatures. Penetrating white light. Photocell option available. No flamepaths to maintain. Low cost of installation, operation and maintenance. KEY FEATURES - Modular LED Luminaire/Floodlight/ZONE 1 Ex em -50ºC to +55ºC DIMENSIONS PROTECTION II 2GD Ex emb II T4/T5/T6 IP66/67, Ex tD A21 T100ºC CERTIFICATION ATEX & IEC Ex PENDING BY SIRA Certification Ambient Certificate HDL106 II 2GD Ex emb II T4/T5/T6 IP66/67 ATEX and IEC Ex pending Voltage Range 110V to 254V SPECIFICATION Main Body Marine Grade Aluminium Diffuser Toughened Glass 5mm Gaskets Silicone External Fasteners A4 Stainless Steel Stirrup Bracket Steel Painted or 316 Stainless Steel T Rating T4/T5/T6 Surface Temp 100ºC Weight 6.0kg per module
  • 15. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 14 Composite C M Y CM MY CY CMY K 13 HADAR LIGHTING Zone 1 MODULAR LED LUMINAIRE/FLOODLIGHT - HDL 106 48 x 1.2W LED's 96 x 1.2W LED's 144 x 1.2W LED's ELECTRICAL SPECIFICATIONS Lamp Options Power consumption Power factor Power supply Electrical Specification ORDERING MATRIX Field Options Up to 6mm 2 clamp terminals for live, neutral, earth and looping are provided. Internal and external earth as standard. Screw terminals upon request. Installation document AL10320 supplied. 2 x M20, one fitted with approved stopper plug, other entries available on request. INSTALLATION Terminals Cable Entries Via stirrup bracket, other mounting accessories available.Suspension Installation 1) Typical ordering reference HDL1061W0000. 2) For Photometric Data contact the sales office. Notes Product Version Fittings 0.95 110V - 254V 47/63Hz AC/DC Cable Entries Other Options 80W Max 160W Max 240W Max Beam Pattern HDL106 1 - 48 LED's 2 - 96 LED's 3 - 144 LED's W - Wide M - Medium N - Narrow 0 - Painted steel external brackets 1 - 316 SS external brackets 0 - M20 5 - M25 00 - Standard
  • 16. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 15 Composite C M Y CM MY CY CMY K 2 x 18W Compact fluorescent lamp for mains operation. Ideal for exit signs - wall or ceiling mounted. Visible Glass area 300mm x 150mm (standard size for fire exit signage). Mild Steel painted as standard (Stainless steel also available). Simple Installation. Straightforward maintenance. Recessed or surface mounting. For Standard Ex em Recessed Luminaire see data sheet HDL 102. Lightweight and robust construction. Mounting in any attitude. Low profile. Continuous monitoring of fluorescent lamps ensures safe end of life shutdown. by electronic ballast in accordance with HSE safety notice 8/05. Overvoltage protection 320V for 1 minute. Quick lamp start and flicker free operation control gear. Cable entries in any face or rear. Can be supplied with signage or facility for end user to fit own. Other warning signage can be used. EMERGENCY VERSION Standard emergency - one fluorescent lamp remains at a reduced output. Can be operated maintained or non maintained. HADAR LIGHTING Zone 1 Ex em BULKHEAD FIRE EXIT RECESSED LUMINAIRE - HDL 108 KEY FEATURES - Zone 1 Ex em Bulkhead Fire Exit Recessed Luminaire 14 Standard Range -40ºC to +55ºC T3 -40ºC to +35ºC T4 Emergency range -15ºC to +55ºC T3 -15ºC to +35ºC T4 DIMENSIONS PROTECTION II 2GD Ex emb II T3/T4 IP64 Ex tD A21 T90ºC CERTIFICATION ATEX & IEC Ex CERTIFIED BY SIRA Certification Ambient Certificate HDL 108 II 2GD Ex emb II T3/T4 IP64 IEC Ex SIR 06.0027 SIRA 06 ATEX 3080 Voltage Range 110V - 254V 2 x 18W Std 3kg 2 x 18W Emergency 3.5kg Weight Incorporates the new ''End of Life'' (EoL) protection circuit ballast - according to DIN EN 61347-2-3 and IEC 60079-7 Ed.4 Annex H Lamp FIRE EXIT SIGN Visible glass area 300mm x 150mm (standard size for fire exit signage) Wall or ceiling mounted. Can be supplied with signage or facility for end user to fit own. Other warning signage can be used. (Surface Mount Variant) SPECIFICATION Enclosure Steel Powder Coated Diffuser Frame Or Stainless Steel Diffuser Toughened Prismatic Glass Gasket Silicone External Fasteners A4 Stainless Steel T Rating T3/T4 Gas and Dust Surface Temp 90ºC
  • 17. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 16 Composite C M Y CM MY CY CMY K 15 Better 220V - 254V, 47/63 Hz AC/DC Than 110V - 130V, 47/63 Hz AC/DC 0.95 Emergency version as above - AC only ELECTRICAL SPECIFICATIONS Lamp Options Power consumption Power factor Power supply Electrical Specification HADAR LIGHTING Zone 1 Ex em BULKHEAD FIRE EXIT - RECESSED LUMINAIRE - HDL 108 HDL108 S - Non Emergency E - Emergency R - Recessed S - Surface Mount H - High Voltage (220V - 254V) M - Medium Voltage (110V - 130V) 0 - M20 Entries 5 - M25 Entries 218 - 2 x 18W ORDERING MATRIX Field 0ptions Fittings Voltage Cable Entries Up to 6mm2 clamp terminals for live, live switched, neutral, earth and looping are provided. Internal and external earth as standard. Screw terminals upon request Installation document AL10091 supplied To suit individual customer requirements INSTALLATION Terminals Cable Entries Via internal mounting holesSuspension Installation 1) Final Product Code should be in the format: HDL108SRH0218 2) Please specify any signage required at the point of ordering. 3) Mild steel as standard, contact the sales office for stainless steel. 4) For Photometric Data contact the sales office. Notes Product Version Lamp Options 2 x 18W CFL STD 32W circuit watts at 240V - 0.14A (120V - 0.28A) 2 x 18W CFL EM 36W circuit watts at 240V - 0.15A (120V - 0.3A)
  • 18. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 17 Composite C M Y CM MY CY CMY K 2 x 18W Compact fluorescent lamp for mains operation or emergency option. Ideal for exit signs - wall or ceiling mounted. Simple Installation. Straightforward maintenance. Emergency version available. Various colour diffusers available - suitable for Helideck or obstruction type lighting. Lightweight and robust construction. Short gaskets for proven ingress protection. Mounting in any attitude. Features mounting points compatible with Unistrut support systems and accessories. Low Profile. Continuous monitoring of fluorescent lamps ensures safe end of life shutdown by electronic ballast in accordance with HSE safety notice 8/05. Overvoltage protection 320V for 1 minute. Quick lamp start and flicker free operation control gear. Supplied complete with lamps. Uses standard compact fluorescent lamps. Bulkhead fitting interchangeable with spares of Hadar Exe Fluorescent Luminaire. EMERGENCY VERSION Standard emergency - one fluorescent lamp remains at a reduced output. Can be operated maintained or non maintained. HADAR LIGHTING Zone 1 Ex em BULKHEAD FIRE EXIT LUMINAIRE - PLASTIC - HDL 109 KEY FEATURES - Zone 1 Ex em Bulkhead / Fire Exit Luminaire - Plastic SPECIFICATION Enclosure Polycarbonate Mounting Bracket Aluminium or Steel Powder Coated Gasket Silicone External Fasteners A4 Stainless Steel T Rating T3 Gas and Dust Surface Temp 100ºC Standard Range -20ºC to +40ºC Emergency Range -15ºC to +40ºC DIMENSIONS PROTECTION II 2GD Ex emb II T3 IP66/67 Ex tD A21 T100ºC CERTIFICATION ATEX & IEC Ex CERTIFIED BY SIRA Certification Ambient Certificate HDL 109 II 2GD Ex emb II T3 IP66/67 IEC Ex SIR060026X SIRA 06 ATEX 3079X Voltage Range 110V - 254V 2 x 18W Weight Incorporates the new ''End of Life'' (EoL) protection circuit ballast - according to DIN EN 61347-2-3 and IEC 60079-7 Ed.4 Annex H Lamp FIRE EXIT SIGN Wall or ceiling mounted. Can be supplied with signage or facility for end user to fit own. Other warning signage can be used. 2.5kg 16 2 x 18W Emergency 3kg
  • 19. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 18 Composite C M Y CM MY CY CMY K 17 HADAR LIGHTING Zone 1 Ex em BULKHEAD FIRE EXIT LUMINAIRE - PLASTIC - HDL 109 Better 220V - 254V, 47/63 Hz AC/DC Than 110V - 130V, 47/63 Hz AC/DC (2 x 18W/2 x 36W only) 0.95 Emergency version as above - AC Only ELECTRICAL SPECIFICATIONS Lamp Options Power consumption Power factor Power supply Electrical Specification HDL109 S - Non Emergency E - Emergency U - Loop In/Out (Unistrut) L - Loop In/Out (Bracket) P - Pole Mount H - High Voltage (220V - 254V) M - Medium Voltage (110V - 130V) 0 - M20 Entries 5 - M25 Entries 218 - 2 x 18W ORDERING MATRIX Field Options Fittings Voltage Cable Entries Up to 6mm2 clamp terminals for live, live switched, neutral, earth and looping are provided. Internal and external earth as standard. Screw terminals upon request. Installation document AL10090 supplied. 2 x M20. Pole mount fittings supplied with 1 x M20 other entries available on request. INSTALLATION Terminals Cable Entries Via bracket supplied or Unistrut reflector.Suspension Installation 1) Final Product Code should be in the format: HDL109SUH0218 2) For Photometric Data contact the sales office. 3) Brass earth continuity gland plates are available, contact sales office for more information. Notes Product Version Lamp Options 2 x 18W CFL STD 32W circuit watts at 240V - 0.14A (120V - 0.28A) 2 x 18W CFL EM 36W circuit watts at 240V - 0.15A (120V - 0.3A)
  • 20. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 19 Composite C M Y CM MY CY CMY K Simple installation. Straightforward maintenance. Integral control gear - easily removed. Wide choice of voltage and lamp options. Ex e terminal chamber. Internal flamepaths eliminating risk of corrosion and costly damage. Control gear and associated components housed in separate easily removed assembly. The unique innovative design allows luminaires to be easily converted. from Zone 1 to Zone 2 and vice versa. Lamp types and wattages can also be easily changed by new easily removed control gear assembly. Elliptical or tubular lamps. Zone 2 variants available. Optional external reflector - ideal for warehousing. KEY FEATURES - Zone 1 Ex ed or Ex de Wellglass SPECIFICATION Main Body Marine Grade Aluminium Lamp Glass Toughened Glass External Fasteners A4 Stainless Steel T Rating T3/T4/T5 Surface Temperature 195ºC External Reflecter Aluminium -20ºC to +50ºC PROTECTION II 2GD Ex ed or de IIC T3 IP66/67 Ex tD A21 195ºC CERTIFICATION ATEX & IEC Ex CERTIFIED BY SIRA Certification Ambient Certificate HDL 133 HDL 134 HDL 113 HDL 114 II 2GD Ex ed or de IIC T3 IP66/67 Certificate pending Voltage Range see table below DIMENSIONS DescriptionType 55W & 85W QL LAMPS 165W QL LAMPS 50W to 150W SON, MBI, MBF, GLS 150W to 400W SON, MBI, MBF, GLS 110V to 130V 220V to 240V 50/60Hz AC/DC 220V to 240V 50/60Hz AC/DC 220V, 230V, 240V, 250V 50/60Hz 220V, 230V, 240V, 250V 50/60Hz Voltage HADAR LIGHTING Zone 1 WELLGLASS - HDL 113 - HDL 114 - HDL 133 - HDL 134 18 Weight 10kg 15kg 13kg 18kg
  • 21. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 20 Composite C M Y CM MY CY CMY K 19 HADAR LIGHTING Zone 1WELLGLASS - HDL 113 - HDL 114 - HDL 133 - HDL 134 HDL133S HDL134S HDL113S HDL114S 11 – 110V 22 – 220V 23 – 230V 24 – 240V 25 – 250V 5 – 50Hz 6 – 60Hz 00 – 2 x M20 05 – 2 x M25 55 – 55W 85 – 85W 165 – 165W 50 – 50W 70 – 70W 80 – 80W 100 – 100W 125 – 125W 150 – 150W 250 – 250W 400 – 400W Q – QL Lamp M – MBF Mercury H – MBI Metal Halide E – SON High Pressure Sodium G – GLS ORDERING MATRIX Field Options Voltage Product Frequency Cable Entries Lamp Options Options Up to 6mm2 clamp terminals for live, live switched, neutral, earth and looping are provided. Internal and external earth as standard. Installation document AL10173 supplied. 2 x M20. Other entries available on request INSTALLATION Terminals Cable Entries Via stirrup bracket supplied. See drawings opposite.Suspension Installation Notes 1) Final Product Code should be in the format: HDL113S24500400E 2) For Photometric Data contact the sales office. 3) External reflector item no. ALA90056. 0.95 0.85 ELECTRICAL SPECIFICATIONS Lamp Options Lamp holder Power factor Power consumption Electrical Specification 55W QL 85W QL 165W QL 50W MBF 80W MBF 125W MBF 250W MBF 400W MBF 50W SON 70W SON 150W SON 250W SON 400W SON 70W MBI 100W MBI 150W MBI 250W MBI 400W MBI 500W (Max) GLS N/A N/A N/A E27 E27 E27 E40 E40 E27 E27 E40 E40 E40 E27 E27 E27 E40 E40 E40 60W 95W 182W 55W 90W 140W 280W 440W 55W 80W 170W 275W 440W 80W 115W 170W 280W 440W 500W Ex de Ex ed CERTIFICATION Type Ex ed Certification Ex de HDL 113 HDL 133 HDL 134 HDL 114
  • 22. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 21 Composite C M Y CM MY CY CMY K 150W, 250W and 400W discharge lamps. 500W max tungsten halogen lamp. Simple installation. Straightforward maintenance. Integral control gear. wide choice of voltage options. Marine grade aluminium. Lightweight. Robust. Ex e junction box. Suitable for use with twin arc lamps. Wide beam reflector. KEY FEATURES - Zone 1 Ex de Floodlight SPECIFICATION Main Body Marine Grade Aluminium Lamp Glass Toughened Soda Lime External Fasteners A4 Stainless Steel T Rating T2 and T3 150W -20ºC to +40ºC T3 250W -20ºC to +40ºC T3 400W -20ºC to +40ºC T3 (110V, 120V, 220V) 400W -20ºC to +40ºC T2 (230V / 240V) 500W -20ºC to +40ºC T2 DIMENSIONS PROTECTION II 2G Ex de IIB T2/T3 IP56 CERTIFICATION ATEX & IEC Ex CERTIFIED BY SIRA Certification Ambient Certificate HDL 117 II 2G Ex de IIB T2/T3 IP56 IEC Ex SIR 07.0023 SIRA 07 ATEX 1059 Voltage Range 110V to 240V Discharge 20 kg GLS / TH 15 kg WeightLamp HADAR LIGHTING Zone 1 FLOODLIGHT - HDL 117 20
  • 23. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 22 Composite C M Y CM MY CY CMY K Exe terminal chamber with terminal block suitable for looping 6mm2 cable. 2 x M20 (other entries available on request). INSTALLATION Terminals Cable Entries Steel mounting bracket. See dimensions above for fixing.Suspension ELECTRICAL SPECIFICATIONS 150W 250W 400W 500W Lamp Options Power consumption Power factor Power supply Electrical Specification 170W 280W 435W 500W 0.85 110V, 120V, 220V, 230V 240V, 50/60 Hz 21 HADAR LIGHTING Zone 1 FLOODLIGHT - HDL 117 Installation Installation document AL10204 supplied. HDL 117S 11 – 110V 12 – 120V 22 – 220V 23 – 230V 24 – 240V 5 – 50Hz 6 – 60Hz 0 – 2 x M20 5 – 2 x M25 150 - 150W 250 – 250W 400 – 400W 500 – 500W H – MBI Metal Halide E – SON High Pressure Sodium T – Tungsten Halogen ORDERING MATRIX Field Options Voltage Product Frequency Cable Entries Lamp Options Options 1) Final Product Code should be in the format: HDL117S2450400E 2) For Photometric Data contact the sales office. Notes
  • 24. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 23 Composite C M Y CM MY CY CMY K The Zone 2 EEx nA Fluorescent Luminaire is designed from a high specification of corrosion resistant glass reinforced polyester body and high impact polycarbonate diffuser to give the highest protection to ATEX standards for EEx nA applications. The luminaire features stainless steel diffuser retaining clips and zinc steel gear tray for rapid installation and easy maintenance. 18W, 36W, 58W Single or Twin. High specification. SIRA certified. Rapid installation. Ease of maintenance. Certified components. High Frequency Electronic Ballast. High Impact GRP Base. High Impact Polycarbonate Diffuser. Stainless Steel Diffuser Clips As Standard. Loop-in/Loop-Out as standard. Through wired versions available. Low Smoke Zero Halogen Option. IP65 EMERGENCY VERSION Twin Unit 3 Hour Battery duration HADAR LIGHTING Zone 2 EEx nA FLUORESCENT LUMINAIRE - EMERGENCY FLUORESCENT - HDL 220 KEY FEATURES - Zone 2 EEx nA Fluorescent Luminaire / Emergency Fluorescent 22 SPECIFICATION Enclosure Corrosion resistant Glass reinforced polyester Diffuser High Impact Polycarbonate Retaining Clips Stainless Steel Gear Tray Zinc Steel Painted Control Gear High Frequency Electronic T Rating T4 Gas and Dust 58W also available in T3 Surface Temp 140ºC Standard Range 18W -20ºC to +40ºC T4 36W -20ºC to +40ºC T4 58W -20ºC to +50ºC T3 -20ºC to +40ºC T4 Emergency Range 18W -15ºC to +40ºC T4 36W -15ºC to +40ºC T4 58W -15ºC to +40ºC T4 DIMENSIONS PROTECTION Ex II 3GD EEx nA II T3/T4 IP65 T140ºC CERTIFICATION ATEX CERTIFIED BY SIRA Certification Ambient Certificate HDL 220 Standard Ex II 3GD EEx nA II T3/T4 IP65 Emergency Ex II 3GD EEx nC T4 IP65 SIRA 03ATEX 4566X Voltage Range 220V - 240V 1 x 18W Luminaires 1 x 36W Luminaires 1 x 58W Luminaires 2 x 18W Luminaires 2 x 36W Luminaires 2 x 58W Luminaires L CFW H 702 1312 1612 702 1312 1612 116 116 116 186 186 186 114 114 114 114 114 114 500 800 1100 500 800 1100 480 x 2 clips per side 400 x 4 clips per side 380 x 5 clips per side Weight Contact Sales Office
  • 25. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 24 Composite C M Y CM MY CY CMY K 23 1 x 18W (600mm Luminaire) 20W 1 x 36W (1200mm Luminaire) 38W 1 x 58W (1500mm Luminaire) 60W 220V - 240V, 47/63 Hz AC/DC 2 x 18W (600mm Luminaire) 39W (Emergency - 49W) Emergency version AC only 2 x 36W (1200mm Luminaire) 73W (Emergency - 83W) 2 x 58W (1500mm Luminaire) 113W (Emergency - 132W) ELECTRICAL SPECIFICATIONS Lamp Options Power consumption Power factor Power supply Electrical Specification HADAR LIGHTING Zone 2 EEx nA FLUORESCENT LUMINAIRE - EMERGENCY FLUORESCENT - HDL 220 HDL220 S - Non Emergency E - Emergency L - Loop In/Loop Out T - Through Wired 118 - 1 x 18W 136 - 1 x 36W 158 - 1 x 58W 218 - 2 x 18W 236 - 2 x 36W 258 - 2 x 58W ORDERING MATRIX Field 0ptions Fittings Suitable for up to 4.00mm2 cable. 6.00mm2 on request. Through Wiring available (Loop In/Loop Out as standard) Low smoke zero halogen available. 20mm clearance holes. INSTALLATION Terminals Cable Entries To suit individual customer requirements.Suspension Options 1) Final Product code should be in the format: HDL220SL118 2) For Photometric data contact the sales office. Notes Product Version Lamp Options Better Than 0.95
  • 26. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 25 Composite C M Y CM MY CY CMY K 55W & 85W QL LAMPS 165W QL LAMPS 50W to 150W SON, MBI, MBF, GLS 150W to 400W SON, MBI, MBF, GLS Simple installation. Straightforward maintenance. Integral control gear - easily removed. Wide choice of voltage and lamp options. Ex e terminal chamber. Internal flamepaths eliminating risk of corrosion and costly damage. Control gear and associated components housed in separate easily removed assembly. The unique innovative design allows luminaires to be easily converted. from Zone 1 to Zone 2 and vice versa. Lamp types and wattages can also be easily changed by new easily removed control gear assembly. Elliptical or tubular lamps. Zone 1 variants available. Optional external reflector - ideal for warehousing. KEY FEATURES - Zone 2 Ex nR Wellglass SPECIFICATION Main Body Marine Grade Aluminium Lamp Glass Toughened Glass External Fasteners A4 Stainless Steel T Rating T3/T4/T5 Surface Temperature 195ºC External Reflecter Aluminium -20ºC to +50ºC PROTECTION II 2GD Ex nR II T3 IP66/67 CERTIFICATION ATEX & IEC Ex CERTIFIED BY SIRA; ABS APPROVED FOR MARINE USE Certification Ambient Certificate HDL 233 HDL 234 HDL 213 HDL 214 II 2GD Ex nR or de IIC T3 IP66/67 Certificate pending Voltage Range see table below DIMENSIONS DescriptionType 110V to 130V 220V to 240V 50/60Hz AC/DC 220V to 240V 50/60Hz AC/DC 220V, 230V, 240V, 250V 50/60Hz 220V, 230V, 240V, 250V 50/60Hz Voltage HADAR LIGHTING Zone 2 Ex nR WELLGLASS - HDL - 223- 224 - 233 - 234 24 Weight 10kg 15kg 13kg 18kg
  • 27. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 26 Composite C M Y CM MY CY CMY K 25 HADAR LIGHTING Zone 2 Ex nR WELLGLASS - HDL - 223- 224 - 233 - 234 HDL233S HDL234S HDL223S HDL224S 11 – 110V 22 – 220V 23 – 230V 24 – 240V 25 – 250V 5 – 50Hz 6 – 60Hz 00 – 2 x M20 05 – 2 x M25 55 – 55W 85 – 85W 165 – 165W 50 – 50W 70 – 70W 80 – 80W 100 – 100W 125 – 125W 150 – 150W 250 – 250W 400 – 400W Q – QL Lamp M – MBF Mercury H – MBI Metal Halide E – SON High Pressure Sodium G – GLS ORDERING MATRIX Field Options Voltage Product Frequency Cable Entries Lamp Options Options Up to 6mm2 clamp terminals for live, live switched, neutral, earth and looping are provided. Internal and external earth as standard. Installation document AL10173 supplied. 2 x M20. Other entries available on request INSTALLATION Terminals Cable Entries Via stirrup bracket supplied. See drawings opposite.Suspension Installation 1) Final Product Code should be in the format: HDL223S24500400E 2) For Photometric Data contact the sales office. 3) External reflector item no. ALA90056. Notes 0.95 0.85 ELECTRICAL SPECIFICATIONS Lamp Options Lamp holder Power factor Power consumption Electrical Specification 55W QL 85W QL 165W QL 50W MBF 80W MBF 125W MBF 250W MBF 400W MBF 50W SON 70W SON 150W SON 250W SON 400W SON 70W MBI 100W MBI 150W MBI 250W MBI 400W MBI 500W (Max) GLS N/A N/A N/A E27 E27 E27 E40 E40 E27 E27 E40 E40 E40 E27 E27 E27 E40 E40 E40 60W 95W 182W 55W 90W 140W 280W 440W 55W 80W 170W 275W 440W 80W 115W 170W 280W 440W 500W
  • 28. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 27 Composite C M Y CM MY CY CMY K The HDL 227 marine grade aluminium alloy floodlight with high performance photometrics is designed to withstand highly corrosive and Zone 2 hazardous area environments. The EEx nR restricted breathing floodlight is constructed from a compact and lightweight design and is available in 150W, 250W and 400W high pressure sodium or metal halide. 150W, 250W, 400W. High performance photometrics. Restricted breathing. SIRA certified. Lightweight design. High pressure sodium/metal halide. Marine Grade Alloy Body. Hinged Front Cover. Toughened Glass. Compact & Lightweight Design. Loop-in, Loop-out as standard. Stirrup Bracket, Galvanised Steel. Stainless Steel Cover & Bracket Screws. IP65. HADAR LIGHTING Zone 2 EEx nR FLOODLIGHT - HDL 227 KEY FEATURES - Zone 2 EEx nR Floodlight 26 -40ºC to +56ºC PROTECTION Ex II 3GD EEx nR II T3/T2 IP65 CERTIFICATION ATEX CERTIFIED BY SIRA Certification Ambient Certificate HDL 227 Ex II 3GD EEx nR II T3/T2 IP65 SIRA 03ATEX 4061 Voltage Range 220V - 240V SPECIFICATION Body Marine Grade Aluminium Alloy LM6 Front Hinged Front Cover Diffuser Toughened Glass 4mm Reflector Symmetrical Dimpled Control Gear Anodised Polished Aluminium Stirrup Bracket Galvanised Steel Cover Stainless Steel Bracket Screws Stainless Steel DIMENSIONS
  • 29. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 28 Composite C M Y CM MY CY CMY K 1) Final Product Code should be in the format: HDL227400SON. 2) For Photometric and Weight Data contact the sales office. 0º -40ºC to +40ºC -40ºC to +56ºC 30º -40ºC to +38ºC -40ºC to +56ºC 45º -40ºC to +37ºC -40ºC to +56ºC 60º -40ºC to +35ºC -40ºC to +56ºC 90º -40ºC to +31ºC -40ºC to +45ºC 0º -40ºC to +40ºC -40ºC to +56ºC 30º -40ºC to +38ºC -40ºC to +56ºC 45º -40ºC to +37ºC -40ºC to +56ºC 60º -40ºC to +35ºC -40ºC to +56ºC 90º -40ºC to +31ºC -40ºC to +45ºC 0º -40ºC to +35ºC -40ºC to +35ºC 30º -40ºC to +35ºC -40ºC to +35ºC 45º -40ºC to +30ºC -40ºC to +35ºC 60º -40ºC to +25ºC -40ºC to +25ºC 90º -40ºC to +25ºC -40ºC to +25ºC AMBIENTS / MOUNTING ATTITUDES W Attitude Point 150W T3 PFC NO PFC 250W T3 400W T2 27 HADAR LIGHTING Zone 2 EEx nR FLOODLIGHT - HDL 227 HDL227 150W - 150W 250W - 250W 400W - 400W SON - High Pressure Sodium MBI - Metal Halide ORDERING MATRIX Field Options Options Notes Product Lamp Options 150W 168W Better 250W 280W Than 400W 433W 0.85 ELECTRICAL SPECIFICATIONS Lamp Options Power consumption Power factor Power supply Electrical Specification Suitable for up to 4.00mm cable. 2 x M20 (other cable entries available upon request). INSTALLATION Terminals Cable Entries See dimensional diagram.Suspension 220V - 240V 50 Hz AC Other voltages and frequencies available upon request.
  • 30. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 29 Composite C M Y CM MY CY CMY K A-Belco Hazardous Area A-Belco Hazardous Area A-Belco Hazardous Area is a specialist manufacturer of hazardous area products for the oil, gas, petro-chemical, pharmaceutical and marine industries worldwide. A division of the A-Belco Group, A-Belco Hazardous Area is an independent UK based manufacturer providing standard and bespoke offerings in the design and assembly of products for Zone Classification Areas 1, 2, 21 & 22, Gas and Dust. The portfolio of products includes Junction Boxes, Control Panels, Control Stations, Lighting, Receptacles, Switches, Circuit Breakers, Cable Glands - all within Ex d, Ex e, Ex ia, Ex nA and Ex nR protection concepts. All products are built in conformance with the ATEX Directive to ensure complete safety. The equipment is independently certified by SIRA, CESI, GOST-R, GOST-K and AUS. Junction Boxes Manufactured from a range of materials including Aluminium Alloy, Stainless Steel and GRP the A-Belco range of explosion-proof Junction Boxes are suitable for use in Zone Classification Areas 1, 2, 21 & 22. The extensive range of enclosures can be used as Junction Boxes with or without terminals and to install electrical equipment such as switches, indicators, ammeters, voltmeters, section switches, remote control switches and transformers. Drilled and threaded to individual customer requirements, optional upgrades include; internal mounting frames, air and drain valves, internal anti-condensate coating, tempered glass windows and IP kits. These robust boxes are suitable for use in any industrial processing plant where the presence of gas, vapours and flammable powders could potentially create an explosive atmosphere. Cable Glands Our innovative range of explosion-proof and weather-proof cable glands are used to provide a connection with electrical equipment that is housed within a flame-proof enclosure; providing a seal that will maintain the specific level of protection that is required. Suitable for use in Zone 1, 2, 21 & 22 Hazardous Areas with all types of armoured cable, the cable glands provide a compound barrier seal around the cable conductors and an environmental seal around on the cable outer sheath. In addition the gas tight seal has been tested to prove compatible with Restricted Breathing equipment. The cable glands allow mechanical cable retention and earth continuity via the cable armour termination. Manufactured in a range of sizes and configurations to suit individual requirements, the cable glands are available off-the-shelf at competitive prices within short lead times. A-Belco Group The A-Belco Group is a diverse group of companies offering electrical and mechanical engineering excellence to a wide range of industries and markets worldwide. Through an extensive range of skills and experience, the A-Belco Group has significant engineering and design capabilities to provide a complete and bespoke first class engineered solution from design to manufacture. The Group incorporates A-Belco Hazardous Area, A-Belco Electrical Engineering, A-Belco Industrial Connectors and MEP Solutions.The extensive product portfolio includes switchgear, electrical distribution panels, electrical accessories and innovative modular building service solutions. Formerly Reyrolle Industrial Accessories and later BALS Engineering, the Group is an established supplier to the UK energy, rail and construction markets. With over 25 years experience in the energy sector, A-Belco excels in quality, price, delivery and after sales support. 28
  • 31. HadarInterimBooklet.FH11 Sat Feb 07 09:33:17 2009 Page 30 Composite C M Y CM MY CY CMY K We reserve the right to amend technical data in accordance with continuous improvement of product specifications and standards. Please refer to the website www.a-belco.co.uk/hazardous or contact the sales office for the latest literature revision. NOTES
  • 32. Hazardous Interim Cover.FH11 Sat Feb 07 11:04:56 2009 Page 1 Composite C M Y CM MY CY CMY K H A Z A R D O U S A R E A A-BELCO CABLE JOINTS, CABLE TERMINATIONS, CABLE GLANDS, CABLE CLEATS FEEDER PILLARS, FUSE LINKS, ARC FLASH, CABLE ROLLERS, CUT-OUTS 11KV 33KV CABLE JOINTS & CABLE TERMINATIONS FURSE EARTHING www.cablejoints.co.uk Thorne and Derrick UK Tel 0044 191 490 1547 Fax 0044 191 477 5371 Tel 0044 117 977 4647 Fax 0044 117 9775582