2. Server specifications EN3702
Imaxel Lab SL 2
History
Date Doc version Description Author
31.01.2011 1.0 Created by MP
22.05.2013 1.1 Last update IT Team
TABLE OF CONTENTS
Overview 3
Internet servers 3
Local workstation 4
Communication ports 5
1.1 Internet servers communication ports ....................................................................................5
1.2 Local workstation communication ports..................................................................................5
3. Server specifications EN3702
Imaxel Lab SL 3
Overview
Imaxel Photo Solution (IPS) system relay on an infrastructure which has two main components:
1. Internet server(s) located in a datacenter that provide front-end service to consumers and
manage the configuration and ecommerce cycle.
2. Local workstation located in the production center, connected to the internet servers to
download orders as well as connected via internal local network to the print servers.
Local workstation is always procured and managed by the client. Internet servers are normally
procured and managed by Imaxel. In the specific case where this is procured by the client (so not using
imaxel servers but others), these need to meet some specifications prior to Imaxel being able to install
the system. These specifications are described below.
When the client opts to install the solution in their own server also assumes the roles and
responsibility of the maintenance of these servers. Tasks such as performance, reliability, backup and
recovery, redundancy etc are not handle by imaxel but directly by the client, who has to set up their IT
processes according to their business requirements.
In order to provide helpdesk support, Imaxel requires that some communications ports are open.
These are described below.
Internet servers
These server will host, among others:
iWEB frontend editor
Management backoffice: Remote Manager, which is a web application to configure the
frontend and the eCommerce developed in ASP.NET that uses a MySQL database in order to
store the information about the products, prices and orders details.
These service may be provided just by one server or by several depending on the expected volume.
Low production (below 100 orders/day requires only one server. High production volumes may require
2 or more servers.
The recommended hardware configurations are:
Low production volume. (up to 100 orders/day) High production volume
Front-end + mySql server Frontend server
CPU 4 cores x 2 GHz CPU 8 cores x 2 GHz
RAM 8 GB RAM 16 GB
HD 2 x 1,2 TB ( RAID 1 Software ) HD 2 x 3,2 TB ( RAID 1 Software )
Bandwidth 100 Mbps Bandwidth 100 Mbps
IP address Static public IP IP address Static public IP
DNS Name At least one domain name DNS Name At least one domain name
Mysql server
CPU 8 cores x 2 GHz
RAM 16 GB
HD 2 x 400 GB ( RAID 1 Software )
IP address Static internal IP
4. Server specifications EN3702
Imaxel Lab SL 4
Software requirements in any server
OS Windows Server 2008 R2 (but not 2012! )
OS Language English
IIS ( Internet Information Server ) Installed
ASP. NET web pages Supported
.NET Framework 1.1 & SP1 Installed
.NET Framework 2.0 Installed
MySQL database Supported
Supplemental language support for non ascii language countries
Install files for complex script and right-to-left
languages (including Thai)
Installed
Install files for East Asian languages Installed
Local workstation
In this server will be installed the application Order Lab Manager. This application is a production
workflow which among others print production orders (job tickets) converts the orders to PDF files and
impose and send them to the Print server.
This workstation must be located in the production center (where printers are located) and should
comply with these minimum requirements.
Core Features
CPU 2 cores x 2.6 GHz
RAM 4 GB
HD 2 x 1TB (raid 1)
Internet connection Bandwidth = 10 Mbps
IP address Static public IP address
The application was developed in C# .NET and requires:
Software requirements
OS Windows XP Pro SP2, windows 7
OS Language English
.NET Framework 1.1 & SP1 Installed
.NET Framework 2.0 Installed
.NET Framework 4.0 Installed
5. Server specifications EN3702
Imaxel Lab SL 5
Communication ports
These servers must be connected each other to share information and handle the workflow. The
connection is handled via some communication ports which must be properly configured by the client
in their LAN and WAN configuration.
1.1 Internet servers communication ports
Ports
80 HTTP
21 Active port FTP
20 Passive port FTP
3389 Remote Desktop Protocol ( RDP ) for Imaxel
helpdesk
1.2 Local workstation communication ports
Usually next ports are open for out coming connections but if your network has a firewall, check them,
please.
Ports
80 HTTP ( connection to web service )
21 Active port FTP ( Download orders )
20 Passive port FTP ( Download orders )
3389 Remote Desktop Protocol ( RDP ) for Imaxel
helpdesk