Anzeige
Anzeige

Más contenido relacionado

Anzeige

DMR40323 CS CHAPTER 1 JJ2023.pdf

  1. 6.53 CONTROL SYSTEM DMR40323 Muhammad Fairuz Bin Muhammad Nasir BEng Aerospace (UPM) MEng Mechanical Industry (UMP) CHAPTER 1: INTRODUCTION TO CONTROL SYSTEM
  2. TOPICS 1.1 General Terms of Control System 1.2 Element of Control System 1. 3 Control System Configuration JJ2023 DMR40323 2 1.4 Advantages of Control System
  3. LEARNING OUTCOMES Define the general terms in control system Recognize the elements of control system Describe the differences of open loop and closed control system JJ2023 DMR40323 3 At the end of this chapter, student should be able to: List the advantages of control system Describe some examples of control system
  4. ENGINEERING AND NON-ENGINEERING FIELDS Use : To achieve the increase of productivity and improved performance of production system Control Engineer : Responsible to plan and design an entire automatic or process control system 2023 DMR40323 4 Electrical Aeronautical Chemical Mechanical Nuclear Economics Management biomedical Biological others
  5. CLASSIFICATION CONTROL SYSTEM Nature Control System Created by Almighty God (human body immunization) Automatic Control System Created by human (auto pilot flight operation, satellite system, space shuttle, robotic system Combination Between Nature and Automatic Control System (car driven by human) JJ2023 DMR40323 5
  6. 1.1 GENERAL TERMS OF CONTROL SYSTEM Control System A system that consist of subsystems and processes assembled for purposes of control the output of process Interconnection of components forming a system configuration that will provide a desired response Automatic Control System A control system that is self regulating or self control without human intervention Process Control System An automatic regulating system in which the output is a variable such as temperature, pressure, flow, liquid level or ph is called process control system Feedback control system A system that maintains a prescribed relationship between the output and input by comparing them and using the difference JJ2023 DMR40323 6 Disturbance a signal that tends to adversely affect the value of the output of the system
  7. Controlled Variable The quantity or condition that is measured and controlled. Normally controlled variable is the output of the system Manipulated Variable The quantity or condition that is varied by the controller so as affect the value of the controlled variable Plants A piece of equipment/set of a machine functioning together, which perform a particular operation Process Progressively continuously operation that consists of a series of controlled action to achieve a particular result JJ2023 DMR40323 7 Systems A combination of components that act together and perform a certain objective Servo Systems Is a feedback control system in which the output is some mechanical position, velocity or acceleration
  8. 1.2 ELEMENTS OF CONTROL SYSTEM OBJECTIVES OF CONTROL SYSTEM INPUT / STIMULUS / ACTUATING SIGNAL CONTROL SYSTEM COMPONENTS PROCESS OUTPUT OF CONTROL SYSTEM output / controlled variable THE PURPOSE • to get the output of the system as per desired input • to control the outputs in some prescribed manner by the inputs through the elements of the control system. JJ2023 DMR40323 8
  9. 1.3 CONTROL SYSTEM CONFIGURATION OPEN LOOP ▪ Control system in which the control or regulating action is independent of the output where output has no effect on the control action. ▪ A system operates without feedback and directly generates the output in response to an input signal. ▪ The output of open loop control system is not compared with the reference input JJ2023 DMR40323 9 Process / Plant Input reference / set point Output controlled variable Controller Function to drives the process or plant.
  10. OPEN LOOP ADVANTAGES • Simple construction • Easy maintenance • No stability problem • Convenient when output is hard to measured & not economy to produced DISADVANTAGES • The output may different from desired input if there is calibration error causes by disturbance/changes • Re-calibration is required from time to time to maintain the required output JJ2023 DMR40323 10
  11. CONTROL SYSTEM CONFIGURATION CLOSED LOOP • A control system in which the control action is influence by the output where the actual output is feedback to the desired input or reference for comparison. • A system that uses a measurement of the output and compares it with desired input JJ2023 DMR40323 11 Process / Plant Desired Input Actual Output Controller Output Transducer / Sensor measurement device to measure the controlled variable/ actual output response feedback path Summing Junction Error / actuating signal Make corrective action and drive the process to desired output
  12. CLOSED LOOP ADVANTAGES • greater accuracy • less sensitive to noise and disturbances • convenient control of transient response and steady state error DISADVANTAGES • more complex and expensive • stability problem • higher cost JJ2023 DMR40323 12
  13. THE DIFFERENCE between closed loop control system and open loop control system Open Loop Control System • Does not have the feedback path • Low accuracy • Sensitive to noise, disturbances and changes in the environment • The system cannot compensate and correct disturbance • Simple and inexpensive Closed Control System • Have the feedback path • Greater accuracy • Less sensitive to noise, disturbances and changes in the environment • The system can compare the output response with the input and make a correction if there is any difference • Complex and expensive JJ2023 DMR40323 13 VS
  14. ADVANTAGES OF CONTROL SYSTEM ❑ Power Amplification – Control system can produce the needed power for amplification called as power gain such as huge radar antenna is positioned by low-power rotation of small knob ❑ Remote Control – Control system useful in remote or dangerous location such as remote-controlled robot used to handle radioactive material ❑ Convenience of Input Form – Control system used to provide convenience by changing the form of input ❑ Compensation For Disturbances – Control System Able To Compensate Disturbances In Order To Achieve The Correct Output
  15. EXAMPLES OF CONTROL SYSTEM JJ2023 DMR40323 15 CAR SPEED CONTROL SYSTEM LIQUID LEVEL CONTROL SYSTEM ROBOTIC ARM CONTROL SYSTEM TEMPERATURE CONTROL SYSTEM
  16. THE DESIGN PROCESS TRANSFORM REQUIREMENTS INTO A PHYSICAL SYSTEM DRAW A FUNCTIONAL BLOCK DIAGRAM TRANSFORM THE PHYSICAL SYSTEM INTO A SCHEMATIC STEP 1 CHAPTER 1, 3 ANALYZE, DESIGN AND TEST TO SEE THAT REQUIREMENTS AND SPECIFICATIONS ARE MET IF MULTIPLE BLOCKS, REDUCE THE BLOCK DIAGRAM TO A SINGLE BLOCK OR CLOSED LOOP SYSTEM USE THE SCHEMATIC TO OBTAIN A BLOCK DIAGRAM, SIGNAL FLOW DIAGRAM, OR STATE SPACE REPRESENTATION JJ2023 DMR40323 16 STEP 2 CHAPTER 1, 2 STEP 3 CHAPTER 1,3 STEP 4 CHAPTER 2 STEP 5 CHAPTER 2 STEP 6 CHAPTER 4,5,6,7
  17. CAR SPEED CONTROL SYSTEM JJ2023 DMR2023 17 The car speed is controlled by pressed or depressed the accelerator pedal, which is, controls the fuel quantity to car engine Desired Speed Transducer Plant Actual Speed Controller (human driver) (car engine) (speedometer) Set point Output Actuator (pedal)
  18. IDENTIFIED JJ2023 DMR40323 18 Process/plant : Controller : Sensor/ Transducer: Input reference : Controlled Variable : Manipulated Variable : ▪ The controller(driver) measures the car speed through speedometer. ▪ When the speed of the car exceed than desire speed, the driver will depress the accelerator pedal to slow down the car. ▪ The car speed control is classified as closed loop or feedback control system. Car engine Driver Speedometer Desired Speed ( Exp : 110 km/h) Actual speed Fuel quantity
  19. LIQUID LEVEL CONTROL SYSTEM JJ2023 DMR2023 19 The objective of this control system is to maintain/control the liquid level in the tank at desire value Plant Desired Level Actual Level Controller Transducer (liquid tank) (level sensor) Set point Output Actuator (control valve) error signal
  20. IDENTIFIED JJ2023 DMR40323 20 Process/plant : Sensor/ Transducer: Input reference : Controlled Variable : Manipulated Variable : Liquid Tank Lever sensor Desired level ( Exp : 5 m high) Liquid level Liquid flow ▪ The fluid level in the tank can be controlled by changing /manipulating the water flow into the tank ▪ The differences between input reference & output signal will generate an error signal. ▪ If the actual level is lower than desired level, the controller will open the control valve to allow a higher flow rate into the tank. ▪ If the actual level is higher than desired level, the control valve turn close to reduce the inflow rate
  21. ROBOTIC ARM CONTROL SYSTEM JJ2023 DMR2023 21 The industrial robot task is pick, move and place parts from one station to another station by pattern recognition process Plant Desired pattern Work Station Controller Transducer (robotic arm) (vision sensor) Set point Output Actuator (computerized)
  22. IDENTIFIED JJ2023 DMR40323 22 Process/plant : Sensor/ Transducer: Input reference : Controlled Variable : Manipulated Variable : ▪ The vision sensor act as a feedback element. ▪ It recognizes the pattern and determines the presence and orientation of the part or object. ▪ The vision signal then is feedback into computerized controller to actuate the robotic arm. ▪ Bar code reading is one of an example of the pattern recognition process. ▪ Then the robot will pick up the part and place it at the work station for work process. Robotic arm Vision sensor Desired pattern Pattern/bar code Part Recognition /line/ barcode
  23. TEMPERATURE CONTROL SYSTEM JJ2023 DMR2023 23 Plant Furnace Desired Temperature Heat Controller Transducer (Thermocouple) Set point Output Actuator (computerized)
  24. IDENTIFIED JJ2023 DMR40323 24 Process/plant : Sensor/ Transducer: Input reference : Controlled Variable : Manipulated Variable : ▪ Thermometer(sensor) to measure the temperature in electric furnace. ▪ The analog signal from thermometer than converted into digital signal by A/D converter and fed into digital controller in computer through interface module. ▪ The actual temperature then compare with input temperature. ▪ If any error occurs, the digital controller sends a signal to the heater through an interface module, amplifier, and relay to bring the temperature of electric furnace to desired value. Furnace Thermocouple Desired Temperature Temperature Current / Heating element
  25. THANK YOU Muhammad Fairuz Bin Muhammad Nasir 019 6600 013 fairuz.nasir@kuantan.kktm.edu.my JJ2023 DMR40323 25