1. B.E Electrical & Electronics Engineering
SARAVANAN.V
#1/156 Mappedu village, Skype Id: saravanan.venu3
Thiruvallur district, Mobile: +966542872913
Tamil nadu– 631402 Email: saravananbeeee86@gmail.com
Objective:
To seek a position in a multicultural workforce by creating long term value for the
organization to the best of my ability and contributing to the process excellence.
Professional Experience:
Working as a Testing & Commissioning Engineer from MAR-2014 to till date in
Schneider Electric as a contractor, KSA
Worked as a protection Engineer from FEB-2013 to march-2014 at Modpro
technical solution. Chennai
Worked as a Testing and commissioning Engineer from 09.12.09 to 21.03.13 at
Inel power system engineers Pvt Ltd in Chennai
Worked as a Electrical Maintenance Engineer in daesung India pvt ltd from June
2008 to DEC 2009 at in Mannur.
Qualification:
Graduated B.E in Electrical & Electronics Engg. in DMI College Of Engineering,
chennai from Anna University 2008
H.sc in DON BOSCO Hr.Sec. School, PANNUR from State board of
Tamilnadu 2003
S.S.L.C in St.Joseph’s. High.Sec. School, kilachery from State board
Tamilnadu 2001
Specialized Skills:
Testing and Commissioning of Protection Relays in various Electrical Systems
Firmware and Software up gradation of the relays
Page 1 of 5
2. B.E Electrical & Electronics Engineering
Knowledge in designing of Control and Protection Schemes of various protection & Switch
gear testing
Commissioning of 132kv, 220kv, 400kv Control and Relay panels
Refurbishment of old electromechanical relays by new numerical relays
Conducting Customer Training Programs
Trouble shouting in Electrical protection systems and fault analyzing
Knowledge in relay setting tools like DIGSI, ,MICOM STUDIO, PCM600 and Cap 540
Knowledge in relay testing kit software’s like OMICRON, FREJA, SMART36.
Technical Experience:
Project details:
Worked in 1*1000MW Nuclear Power plant (kudankulam Tamil nadu) from Dec 2009’ to
July’ 10.
Client: NPCIL
EPC Contractor: NPCIL
Responsibilities
Testing & Commissioning of Power Transformer upto 40MVA
Testing & Commissioning of CT, VT, Power contactors & MCCBs
Worked in 132/33 kV voltage level Switch yard & control panels (Chhattisgarh) from
march’ 13 to July’ 13.
Client: Monnet Ispat
EPC Contractor: Alstom
Responsibilities
Testing & Commissioning of Power Transformer upto 40MVA
Testing & Commissioning of CTs, VTs, LAs, Insulators, Isolators, Breakers, Capacitors,
Inductors, and Control & Relay Panels.
Testing & Commissioning of Micom P143,P141,P142
Testing & Commissioning of ABB relay like Spaj140C
Worked in 66/11 kV voltage level Switchyard and control panels, 11 Kv DG set control
panels (Airport, New Delhi) from Jan’ 09 to May’ 09.
Client: DELHI INTERNATIONAL AIRPORT LIMITED
Customer: GMR
EPC Contractor: LARSON & TOUBRO LIMITED
Contractor: AREVA
Page 2 of 5
3. B.E Electrical & Electronics Engineering
Responsibilities
Testing & Commissioning of Power Transformer upto 40MVA
Testing & Commissioning of CTs, VTs, LAs, Insulators, Isolators, Breakers Control & Relay
Panels.
Worked as a Relay testing Engineer in 400/220/132/33/11kV voltage level control panels
consisting of Distance, Differential, Directional over current and Earth fault protection
relays from Dec’ 09 to Jan 13.
(i) Client: Kharama
EPC Contractor: SIEMENS
(ii) Client: MSETCL
EPC Contractor: SIEMENS
Working as a Relay testing Engineer in 400/220/132/33/11kV voltage level control
panels consisting of Distance, Transformer Differential, Line Differential ,Directional
over current and Earth fault protection relays from Dec’ 09 to Mar’12.
Responsibilities
Testing of Control & Relay Panels Upto 400KV
Testing of Siemens Relay like 7SD522, 7UT613, 7UT612, 7SJ64, 7SJ80, 7UM61, 7SS522.
Testing of MICOM Relay like P441, P443, P543, P546.
Testing of ABB Relay like RET670, RED670.
Alstom PROJECTS HANDLED FROM June’ 13 TO TILL DATE
(1) GENERATOR PROTECTION RELAYS IN HINDALCO MSETCL
SUBSTATIONS(ODISA)
Responsibilities
Testing & Commissioning of Transformer upto 120MVA.
Testing & Commissioning MICOM Relay like P633, P643, P632, P343.
Testing & Commissioning of L&T Switchgear upto 11KV
(2)COMMISSIONING OF LINE DIFFERENTIAL PROTECTION RELAYS
IN NUMALIGARGH REFINARY LIMITED (ASSAM)
RESPONSIBILITIES:
Analyzing the scheme, testing 4 no’s of RED 670 with transformer in between the line
and 2 no’s of REF 543 IED with remote operation from the IED.
DURATION:-MAY-2010
ACHIEVEMENT:-Commissioned all the IED’s with customer’s satisfaction.
Page 3 of 5
4. B.E Electrical & Electronics Engineering
(3)TESTING OF LINE, TRANSFORMER, BUSBAR PROTECTION RELAYS
IN220/132/33 KV SUBSTATION OF BIHAR STATE ELECTRICITY
BOARD (BIHAR)
RESPONSIBILITIES:
Analyzing the scheme, testing of RET 670(TRANFORMER), REL 670(LINE) and RADHA
(BUSBAR) protection IED’s.
Preparing the cable schedule for Event Logger panel, Time synchronization panel and
Bus bar protection panel.
DURATION:-JUNE-2010
ACHIEVEMENT: - Completed the target within the short duration of time.
(4)TESTING OF LINE DIFFERENTIAL, TRANSFORMER DIFFERENTIAL
& FEEDER PROTECTION RELAYS IN 2*130 MW POWER PLANT OF
BPSL, JHARSUGUDA
DURATION:-JULY-2010
(5)RETROFITTING OF GENERATOR, LINE, TRANSFORMER
PROTECTION PANELS & RELAYS IN 6*50 MW GENERATING STATION
OF Rihand Power House UPJVNL, PIPRI (UTTAR PRADESH)
RESPONSIBILITIES:
Replacing of old Electro Magnetic Protection Relays & Panels with Numerical ABB
Protection IED Panels. Testing & commissioning of all the IED’s Like RET 670, REL 670
and REF 615.
DURATION:-August-2010 to February-2011
(6)RETROFITTING OF GENERATOR, LINE, TRANSFORMER
PROTECTION PANELS & RELAYS IN 3*33 MW GENERATING STATION
OF OBRA HYDEL Power House UPJVNL, OBRA (UTTAR PRADESH)
RESPONSIBILITIES:
Replacing old Electro Magnetic Protection Relays & Panels with Numerical ABB Protection
IED Panels. Testing & commissioning of all the IED’s Like RET 670, REL 670 and REF
615.
DURATION:-MARCH-2011 to FEB 2012
Page 4 of 5
5. B.E Electrical & Electronics Engineering
(7)RETROFITTING OF LINE, TRANSFORMER PROTECTION PANELS
& RELAYS IN 1550 MW GENERATING STATION OF OBRA THERMAL
POWER PLANT UPRVUNL, OBRA (UTTAR PRADESH)
RESPONSIBILITIES:
Replacing old Electro Magnetic Protection Relays & Panels with Numerical ABB Protection
IED Panels. Testing & commissioning of all the IED’s Like RET 670, REL 670
OVERSEAS PROJECT:-
DURATION:-March 2014
Responsibilities
Testing and Commissioning various type of Sepam ,Micom, Sel, Siemens Protection Relays,
Testing and commissioning various type of Switchgears Like MCset, Blokset, SM6, RMU.
Preparations of Relay setting calculations,
Retrofitting of new relays with old Electro Mechanical relays schemes
Disturbance analysis, and conducting customer Training.
Schneider Electric Projects
PROJECT: PREVENTIVE AND ANNUAL MAINTENANCE
Client: Zharan, RIYADH
CONSULTANT: DAR
Responsibilities
Testing and Commissioning SM6 type breakers
Testing of CT,VT,Power Transformers , Meters
Testing of SEPAM Relays
PROJECT: REVAMPING OF LV SWITCH GEAR
Page 5 of 5
6. B.E Electrical & Electronics Engineering
Client: Saudi Oger, JEDDAH
Responsibilities
Retrofitting of Master pact up to 4000A
ACHIEVEMENT:-Arranged shutdown continuously by convincing the customer and in
most of the substation all the retrofitting work was done in live condition.
PROJECT: PREVENTIVE AND ANNUAL MAINTENANCE
Client: Hilton Hotel, JEDDAH
Responsibilities
Preventive Maintenance of MCSET ,F400 type breakers
Testing of CT,VT,Power Transformers ,Meters
Testing of SEPAM Relays,
ACHIEVEMENT:-Arranged shutdown continuously by convincing the customer and in
most of the substation all the retrofitting work was done in live condition.
PROJECT: 13.8 Kv switchgear Extension
Client: South Star
Responsibilities
Testing and Commissioning LF2 ,LF1 type breakers
Testing of CT,VT , Meters
Testing of SEPAM 40 & 80 series Relays
PROJECT: 380kv GIS CONTROL & RELAY PANELS
Client: YASREF,YANBU
Responsibilities
Testing of protection Relays like MICOM P543 P546,P643,P143
Testing of Sell 411L
Testing of Siemens like 7UT613,7SD522,7SJ80 Relays
PROJECT: 115KV, 34.5KV, 13.8KV, 4.16KV PROTECTION UPGRADE
Client: SABIC, JUBAIL
Responsibilities
Testing of protection Relays like MICOM P141 P142,P143,P123,P127,P723,P927
Testing of Sepam Relays like M41,S80,T87,M87,S40,MCS025,T40
ACHIEVEMENT:-Arranged shutdown continuously by convincing the customer and in
most of the substation all the retrofitting work was done in live condition.
Page 6 of 5
7. B.E Electrical & Electronics Engineering
PROJECT: 33KV F400 SWICHGEAR
Client: ALMARAI, HAIL
Responsibilities
Testing of Siemens protection Relays like 7SD522 LINE Differential & Distance
Testing of Sepam Relays like S80,T87,S40,T40
Testing of Sell Relays like 411L
PROJECT: REVAMPING OF MV & LV BREAKERS
Client: SWCC JUBAIL
Responsibilities
Testing of MV & LV Breakers like blokset, LF2,LF1,EVOLIS
Testing of ATS Schneider Twido Suite PLC
Testing of 13.8KV MCset Switch gear
ACHIEVEMENT:-Arranged shutdown continuously by convincing the customer and in
most of the substation all the retrofitting work was done in live condition.
PROJECT: 13.8KV PROTECTIION UPGRADE
Client: RIYADH SCHOOL
Responsibilities
Testing of MV & LV Breakers like blokset, LF2 Breaker
Testing of ATS Schneider Twido Suite PLC
Testing of 13.8KV SM6 Switch gear
ACHIEVEMENT:-Arranged shutdown continuously by convincing the customer and in
most of the substation all the retrofitting work was done in live condition and
completed the target within the short duration of time.
PROJECT: 13.8KV PROTECTION UPGRADE
Client: SEC, RIYADH
Responsibilities
Testing of MICOM P543 Line differential Relay
Page 7 of 5
8. B.E Electrical & Electronics Engineering
PROJECT: REVAMPING OF 13.8KV RMU
Client: ARAMCO, MADINAH
Responsibilities
Testing & Commissioning of RMU & VIP 300 Relay
Personal Profile:
• Father’s name: Mr.k.Venu
• Gender: Male
• Marital Status: Single
• D.O.B: July-17th-1986,
• Nationality: Indian
• Languages Known: Tamil, English, Hindi
• Passport No L4322838
• Current CTC: 10000SAR per month
• Notice Period: 2 Month
Permanent Address:
1/156 Mappedu village (post)
Thiruvallur (District) Tamil Nadu- 631 402
South India
Residence: 09965655452
Current contact No: 0542872913
Declaration:
I, hereby declare that the information furnished above is true to the best
of my knowledge and belief.
Date: (V.SARAVANAN)
Page 8 of 5