1. Converter For Electromagnetic Flowmeter
Model AMC2100 Series
GENERAL
AMC2100 series Converter can be used with
AMF series flow tubes in both compact or separate versions.
FEATURES
Three line LCD display Flow rate/Totalizer
Accuracy of +/-0.4% value of reading
Bi-directional flow measurement, current and pulse output
Large digital display
99 times flowrate records for power on/off
MODBUS/HART communication
STANDARD SPECIFICATION
Excitation : Square wave Keyboard : 3 keys from external for programming
Display : 3 lines LCD with illumination and display control.
Line 1 : 11 digit totalizer for forward flow Low Flow Cutoff : 0 to 9.9 %
11 digit totalizer for reverse flow Datalogger Function : 99times flowrate records for power on/off
11 digit totalizer for difference Record Data : Date/Time when Power on/off
Line 2 : 5 digit flowrate / Velocity / % / mA / HZ : Flow rate when Power on/off
Line 3 : Parameter / Query / Clr tot / Query LOG : Totalizer when Power on/off
Alarm, Guidance Damping : 0 to 99 Second
Unit : M3/H , L/H , Kg/H , T/H , L/min Density Setting : 0.1 to 9.99 g/cm2
M3/min , GPH , GPM Self Diagnosis : The following error message is
Measuring Range : Min. 0 to 0.15 m/s indicated during application
: Max. 0 to 15 m/s - Coil fail
Accuracy : +/-0.4% read-out values (Velocity >= 0.5 m/s) - Power fail
: +/-0.002 m/s (Velocity < 0.5 m/s) - Output overranged
Repeatability : +/-0.1% read-out values - Internal error
Current Output : 4-20 mA (Isolated) - Overflow
Load : Max. 600 Ω - Empty pipe
Pulse output : Open collector Cable Entry : PG11
Rating : 3 to 30 VDC, 20 mA Max. Protection Class : IP 65
Pulse Rate : 1)Scale pulse, (Pusle/M3, Pulse/L, Other) Ambient Temperature : -25 to +65 C
: 2)Frequency, 0-5000 Hz Material : Aluminum Alloy
Pulse Width : 50% of band width Power Supply : 90-260 VAC, 50/60 Hz
Alarms : High/Low with open collector output : 24VDC +/-10%(Option)
Rating : 3 to 30 VDC, 20 mA Max. Power Consumption : 3-17 W (depending on the sensor size)
Communication : RS 485(MODBUS Protocol) Weight : 1.4 Kg
: HART signal Mounting : Wall mounting
Data Storage : Operation parameters and totalization : Bracket on 2" pipe
figures are stored by EEPROM for more
than 10 years
ALIA GROUP INC. URL : www.alia-inc.com
113 Barksdale Professional Center, Newark, DE 19711, USA E-mail : alia@alia-inc.com
TEL : + 1 - 302 - 213 - 0106 FAX : + 1 - 302 - 213 - 0107 AMC2100V1.1.8en
ALIAMAG
ALIAMAG
®
2. ALIAMAG Electromagnetic Flowmeter Converter Model AMC2100 Series
DIMENSION
ELECTRICAL CONNECTION
ALIA GROUP INC. AMC2100V1.1.8en Page 2
Fuse
8 12111097654321 1413
F
U
S
E
1:4-20mA output +
2:4-20mA output -
3:Pulse output +
4:Pulse output -
5:RS485+
6:RS485-
Power Supply
90 ~ 260VAC
50/60 Hz
or
24VDC
Cable from sensor
150mm
150 mm
ENT
150 mm
150
mm
70 mm
150mm
70 mm
150
mm
3. ALIAMAG Electromagnetic Flowmeter Converter Model AMC2100 Series
AMC2100- XX- XX- XX Description
AC- 90-260 Vac, 50/60 Hz
DC- 24Vdc, +/-10%
CP- Compact with Sensor
SW- Separate, wall mounting
S2- Separate, 2" mounting bracket
NN RS 485(MODBUS Protocol)
HT HART signal
ALIA GROUP INC. AMC2100V1.1.8en
Communication
Page 3
ACCURACY
CABLE LENGTH BETWEEN SENSOR TO CONVERTER
Mounting
MODEL SELECTION GUIDE
AMC2100 Series
Example:AMC2100-AC-CP-HT
Power supply
0.5 1 2 4 8 10 12
0.0
+1.2
-0.4
-0.8
-1.2
-1.6
+1.6
+0.8
+0.4
Velocity (m/s)
E
R
R
O
R
%
150
100
200
300
60 100 2005 300
60
30
10
10 30
Fluid Conductivity (uS/cm)
M
E
T
E
R
4. COMPACT STRUCTURE
ALIA GROUP INC. AMC2100V1.1.8en
ALIAMAG Electromagnetic Flowmeter Converter Model AMC2100 Series