SlideShare a Scribd company logo
1 of 8
Download to read offline
Bar Code Reader Series
BCL 20
A flexible reader for
a variety of applications




P R O D U C T I N F O R M AT I O N
The benchmark for flexibility.




Laser scanners of the BCL 20 series –
as variable as your requirements demand.


Whether as a single-line scanner for high-density codes, for example, in analysis
automation, with raster optics for reading trays in intra-logistics applications or
for inspecting industrial or printed products: the compact bar code readers of
the BCL 20 series convince with their high level of flexibility and handling reliabili-
ty in all areas.


The broad selection of optics also allows the scanners to be used in difficult
installation situations and in a wide range of applications, both in networks as
well as a standalone solution. Furthermore, the BCL 20 series convinces with its
outstanding reading performance through the automatic adaptation of the
receiver unit to the reading task on each scan. For an extended reading field,
such as that of a bar code reader with focusing function, the new BCL 20 S B is
availabe for higher resolution codes.


By means of simple online commands it is possible to set the reading task
without knowledge of the code. The PC-based BCL-Config tool, which is avail-
able for all Leuze bar code readers, is used to access the full function range.
Simple online commands make it possible to set the reading task without know-
ledge of codes. The BCL Config tool, which can be used for the entire function
range, is available for all bar code readers from Leuze electronic Connectivity.
Connection to industrial or Ethernet-based networks is now done directly via our
MA 200i modular interfacing units.
Universally usable – fast integration –
simple to operate.




The advantages of the bar code reader series BCL 20.


 Various optics models: Different models with front or lateral beam exit ena-
 ble optimum use of the installation space. Depending on the code alignment,
 single-line or raster scanners offer optimised reading capacity


 High, constant scanning rate up to 1000 scans/s: Considerable increase in
 the reading reliability through multiple decoding of the read codes, even during
 fast processes


 Large depth of field and wide opening angle: High reading capacity with codes
 having line thicknesses as narrow as 150 μm facilitates front or lateral reading
 on your goods


 Integrated multiNet: Up to 31 scanners can be networked in Leuze electronic's
 own scanner network with minimal installation effort and, if desired, integrated
 via gateways to the fieldbus level or directly to the host


 Simple operation: With the aid of online commands such as AutoConfig, the
 scanner can be set optimally, even without knowledge of the code


 Easy configuration: The PC-based BCL-Config operating software for all Leuze
 bar code readers simplifies adjustments and direct communication with the
 scanner through graphical configuration


 Blue laser diodes with extended reading field without focus adjustment for
 higher resolution codes and optimized optics for glossy and cylindrical objects.
Interface variants and
                                                                                                           connector units.




Light source
gew
hgagh                                              Fig.: BCL 21/22                                                                  Fig.: BCL 21/22
föjfäää                                            Front beam exit                                                                  Lateral beam exit




 BCL 21                                                                    BCL 22

                 multi Net



   Integrated RS 485 interface and                                               Integrated, freely configurable RS 232 interface
   RS 232 service interface
                                                                                 Standalone operation or daisy chain with up to four
   Freely configurable or direct connection to the                               BCL 22 devices
   Leuze electronic multiNet network
                                                                                 2 switching inputs and 2 switching outputs
   1 switching input and 1 switching output
                                                                                 Direct connenction to PROFIBUS or other networks via
   Connect up to 31 scanners to one master in the                                modular connector units as gateways
   Leuze electronic multiNet



 Both systems are available with a 15-pin Sub-D connector or with a system plug for directly connecting to a
 modular connector unit.

  Modular connector units                            BCL 21                                                 BCL 22
  MA 22 DC

  MA 2

  MA 4 (D) 1xx

  MA 4 (D)

  MA 42 IS/DP-k
                               PROFINET IO/RT, PROFIBUS DP, INTERBUS, Ethernet        PROFINET IO/RT, PROFIBUS DP, INTERBUS, Ethernet
  MA 200i
                               TCP/IP, UDP, IP, EtherCAT, DeviceNet, CANopen          TCP/IP, UDP, IP, EtherCAT, DeviceNet, CANopen
  Mounting devices

  BT 20

  BT 21
Technical data




Optical data                       BCL 21                                    BCL 22                                    BCL 2x S B
Type                               line or raster scanner (10 lines)         line or raster scanner (10 lines)         line scanner
Light source                       laser diode, red, approx. 650 nm          laser diode, red, approx. 650 nm          laser diode, blue, approx. 405 nm
Beam exit                          front or lateral                          front or lateral                          front or lateral
                                   800 scans/s (N-/F-optics),                800 scans/s (N-/F-optics),                800 scans/s (B-optics)
Scanning rate
                                   1000 scans/s (M-optics)                   1000 scans/s (M-optics)
Max. usable opening angle          approx. 65°                               approx. 65°                               approx. 65°
Optics models / resolution         N-/M-/F-optics, see reading field curves   N-/M-/F-optics, see reading field curves   N-/M-/F-optics, see reading field curves
Read distance                      see reading field curves                   see reading field curves                   see reading field curves
                                   Class 2 acc. to EN 60825-1, CDRH          Class 2 acc. to EN 60825-1, CDRH          Class 2 acc. to EN 60825-1, CDRH
Laser safety class
                                   (U.S. 21 CFR 1040.10)                     (U.S. 21 CFR 1040.10)                     (U.S. 21 CFR 1040.10)
Bar code data
Code types                         2/5l, Code 39, Code 93, Code 128,         2/5l, Code 39, Code 93, Code 128,         2/5l, Code 39, Code 93, Code 128,
                                   EAN 128, EAN/UPC, EAN add-on,             EAN 128, EAN/UPC, EAN add-on,             EAN 128, EAN/UPC, EAN add-on,
                                   Codabar (monarch), Pharmacode             Codabar (monarch), Pharmacode             Codabar (monarch), Pharmacode
Number of codes per scan           6                                         6                                         6
Number of codes per reading gate   62                                        62                                        62
Electrical data
Interface                          RS 485                                    RS 232                                    RS 232
Protocols                          Leuze Standard, multiNet, Ack/Nak         Leuze Standard, multiNet, Ack/Nak,        Leuze Standard, multiNet, Ack/Nak,
                                                                             3964, DC                                  3964, DC
Baud rate                          110 ... 115200 baud                       110 ... 115200 baud                       110 ... 115200 baud
Data formats                       7, 8, 9 data bits                         7, 8, 9 data bits                         7, 8, 9 data bits
                                   none, even, odd parity                    none, even, odd parity                    none, even, odd parity
                                   1, 2 stop bit(s)                          1, 2 stop bit(s)                          1, 2 stop bit(s)
Service interface                  RS 232, 9600 baud, 8 data bits,           RS 232, 9600 baud, 8 data bits,           RS 232, 9600 baud, 8 data bits,
                                   no parity, 1 stop bit                     no parity, 1 stop bit                     no parity, 1 stop bit
Switching inputs/outputs           1 switching input, 1 switching output     2 switching inputs, 2 switching outputs   2 switching inputs, 2 switching outputs
Operating voltage                  10 … 30 V DC                              10 … 30 V DC                              10 … 30 V DC
Power consumption                  max. 3.2 VA                               max. 3.2 VA                               max. 3.2 VA
Operating and display elements
LEDs                               1 Pwr/Err LED, 1 Decode LED               1 Pwr/Err LED, 1 Decode LED               1 Pwr/Err LED, 1 Decode LED
Mechanical data
Protection class                   IP 54                                     IP 54                                     IP 54
Weight                             180 g (0.8 m)/260 g (3 m cable)           180 g (0.8 m)/260 g (3 m cable)           180 g (0.8 m)/260 g (3 m cable)
Dimensions (W × H × D)             82 × 68 × 28 mm3                          82 × 68 × 28 mm3                          82 × 68 × 28 mm3
Housing                            plastic ABS / PC                          plastic ABS / PC                          plastic ABS / PC
Environmental data
Operating temperature range        0 °C … +40 °C                             0 °C … +40 °C                             0 °C … +40 °C
Storage temperature range          -20 °C … +60 °C                           -20 °C … +60 °C                           -20 °C … +60 °C
Air humidity                       max. 80% rel. humidity, non-condensing    max. 80% rel. humidity, non-condensing    max. 80% rel. humidity, non-condensing
Vibration                          IEC 60068-2-6, FC test                    IEC 60068-2-6, FC test                    IEC 60068-2-6, FC test
Shock                              IEC 60068-2-27, Ea test                   IEC 60068-2-27, Ea test                   IEC 60068-2-27, Ea test
Electromag. compatibility          IEC 61000-6-2, -6-3                       IEC 61000-6-2, -6-3                       IEC 61000-6-2, -6-3
Certifications                               CDRH       C     US                       CDRH       C     US                      CDRH        C     US
Reading field curve, N-optics                                                                                                                                                              Reading field curve, SB-optics
                             60
                                                                                                                                                                               m = 0,15                               90
                             50
                                                                                                                                                                                                                      80                                                                                                   m = 0.165 mm
                                                                                                                                                                               m = 0,2
                                                                                                                                                                                                                      70
                             40
 Reading field width [mm]




                                                                                                                                                                                           Reading field width [mm]   60                                                                                                   m = 0.2 mm

                             30                                                                                                                                                                                       50
                                                                                                                                                                                                                                                                                                                           m = 0.3 mm
                                                                                                                                                                                                                      40
                             20
                                                                                                                                                                                                                      30
                                                                                                                                                                                                                      20
                             10




                                                                                                                                                                                                                                                                      m = 0.165 mm


                                                                                                                                                                                                                                                                                     m = 0.2 mm




                                                                                                                                                                                                                                                                                                        m = 0.3 mm
                                                                                                                                                                                                                      10
                                                                                                                                      m = 0,15




                                                                                                                                                               m = 0,2




                                                                                                                                                                                                                       0
                                                                                                                                                                                                                      -10
                             -10                                                                                                                                                                                      -20
                                                                                                                                                                                                                      -30
                             -20
                                                                                                                                                                                                                      -40

                             -30                                                                                                                                                                                      -50
                                                                                                                                                                                                                      -60
                             -40                                                                                                                                                                                      -70
                                                                                                                                                                                                                      -80
                             -50
                                                                                                                                                                                                                      -90
                                                                                                                                                                                                                            0   20   40   60   80   100   120   140      160            180       200     220        240
                             -60
                                0    10        20         30          40           50            60               70                        80            90             100

                                                     Read distance [mm]                                                                                                                                                                   Read distance [mm]


Reading field curve, M-optics
                            150
                                                                                                                                                                               m = 0,2


                                                                                                                                                                               m = 0,3
 Reading field width [mm]




                            100

                                                                                                                                                                               m = 0,5
                                                                                                                                                                               m = 0,8


                              50



                                                                                                                                                           m = 0,5
                                                                                                                                                           m = 0,8
                                                                                     m = 0,2




                                                                                                            m = 0,3




                             -50




                            -100




                            -150
                                0   20    40        60     80        100     120         140         160       180               200              220       240          260

                                                         Read distance [mm]


Reading field curve, F-optics
                            150
                                                                                                                                                                               m = 0,5


                                                                                                                                                                               m = 0,8
                            100                                                                                                                                                m = 1,0
 Reading field width [mm]




                             50
                                                                                                                      m = 0,5




                                                                                                                                                       m = 0,8
                                                                                                                                                       m = 1,0




                             -50




                            -100




                            -150
                                0   40    80        120        160     200         240         280         320                  360              400       440           480

                                                     Read distance [mm]
Optoelectronic Sensors
Cubic Series
Cylindrical Sensors, Mini Sensors, Fiber Optic Amplifiers
Measuring Sensors
Special Sensors
Light Curtains
Forked Sensors
Double Sheet Monitoring, Splice Detection
Inductive Switches
Accessories
Identification Systems
Data Transmission Systems
Distance Measurement
Bar Code Readers
RF-IDent-Systems
Modular Interfacing Units
Industrial Image Processing Systems
Optical Data Transmission Systems
Optical Distance Measurement/Positioning
Mobile Code Readers
Safety Sensors
Safety Systems
Safety Services
Safety Laser Scanners
Safety Light Curtains
Transceivers and Multiple Light Beam Safety Devices
Single Light Beam Safety Devices
AS-i-Safety Product Range
Safety Sensor Technology for PROFIBUS DP
Safety Switches, Safety Locking Devices and Safety Command Devices
Safety Relays
Sensor Accessories and Signal Devices
Safety Engineering Software
Machine Safety Services




Leuze electronic GmbH + Co. KG
                                                                     en 02-2012/06 50031292




In der Braike 1
D-73277 Owen / Germany
Phone +49 7021 573-0
Fax +49 7021 573-199
info@leuze.de
www.leuze.com

More Related Content

What's hot

product_data_sheet0900aecd806ee368
product_data_sheet0900aecd806ee368product_data_sheet0900aecd806ee368
product_data_sheet0900aecd806ee368
aniruddh Tyagi
 
Matrix eternity mex presentation
Matrix eternity mex presentationMatrix eternity mex presentation
Matrix eternity mex presentation
matrixtelesol
 
Id 12-datasheet
Id 12-datasheetId 12-datasheet
Id 12-datasheet
Atul Uttam
 
8051 serial communication
8051 serial communication8051 serial communication
8051 serial communication
asteriskbimal
 

What's hot (18)

Xu100
Xu100Xu100
Xu100
 
Embedded System Microcontroller Interactive Course using BASCOM-AVR - Lecture12
Embedded System Microcontroller Interactive Course using BASCOM-AVR - Lecture12Embedded System Microcontroller Interactive Course using BASCOM-AVR - Lecture12
Embedded System Microcontroller Interactive Course using BASCOM-AVR - Lecture12
 
Xb5 r batteryless wireless switch
Xb5 r batteryless wireless switchXb5 r batteryless wireless switch
Xb5 r batteryless wireless switch
 
bacnet
bacnetbacnet
bacnet
 
Datacomm 100G QSFP28 CLR4 Optical Transceivers
Datacomm 100G QSFP28 CLR4 Optical TransceiversDatacomm 100G QSFP28 CLR4 Optical Transceivers
Datacomm 100G QSFP28 CLR4 Optical Transceivers
 
DS25CP102 (English)
DS25CP102 (English)DS25CP102 (English)
DS25CP102 (English)
 
R fmodem data_sheet_337
R fmodem data_sheet_337R fmodem data_sheet_337
R fmodem data_sheet_337
 
product_data_sheet0900aecd806ee368
product_data_sheet0900aecd806ee368product_data_sheet0900aecd806ee368
product_data_sheet0900aecd806ee368
 
Sonifex New Product Updates sept 2011
Sonifex New Product Updates sept 2011Sonifex New Product Updates sept 2011
Sonifex New Product Updates sept 2011
 
Matrix eternity mex presentation
Matrix eternity mex presentationMatrix eternity mex presentation
Matrix eternity mex presentation
 
Essential Guide Interfaces I/O 2010
Essential Guide Interfaces I/O 2010Essential Guide Interfaces I/O 2010
Essential Guide Interfaces I/O 2010
 
Bo75j33210d 10gbase-bx-d x2 transceiver tx1330nm-rx1270 10 kilometer singlemo...
Bo75j33210d 10gbase-bx-d x2 transceiver tx1330nm-rx1270 10 kilometer singlemo...Bo75j33210d 10gbase-bx-d x2 transceiver tx1330nm-rx1270 10 kilometer singlemo...
Bo75j33210d 10gbase-bx-d x2 transceiver tx1330nm-rx1270 10 kilometer singlemo...
 
Ap psbias-1 p2-afr
Ap psbias-1 p2-afrAp psbias-1 p2-afr
Ap psbias-1 p2-afr
 
Bo75j33240d 10gbase-bx-d x2 transceiver tx1330nm-rx1270 40_kilometer singlemo...
Bo75j33240d 10gbase-bx-d x2 transceiver tx1330nm-rx1270 40_kilometer singlemo...Bo75j33240d 10gbase-bx-d x2 transceiver tx1330nm-rx1270 40_kilometer singlemo...
Bo75j33240d 10gbase-bx-d x2 transceiver tx1330nm-rx1270 40_kilometer singlemo...
 
Id 12-datasheet
Id 12-datasheetId 12-datasheet
Id 12-datasheet
 
Bo32j13210d 10gbase-lr x2 transceiver 1310nm 10 kilometer singlemode sc-duple...
Bo32j13210d 10gbase-lr x2 transceiver 1310nm 10 kilometer singlemode sc-duple...Bo32j13210d 10gbase-lr x2 transceiver 1310nm 10 kilometer singlemode sc-duple...
Bo32j13210d 10gbase-lr x2 transceiver 1310nm 10 kilometer singlemode sc-duple...
 
8051 serial communication
8051 serial communication8051 serial communication
8051 serial communication
 
Bo32j15280d 10gbase-zr x2 transceiver 1550nm 80 kilometer singlemode sc-duple...
Bo32j15280d 10gbase-zr x2 transceiver 1550nm 80 kilometer singlemode sc-duple...Bo32j15280d 10gbase-zr x2 transceiver 1550nm 80 kilometer singlemode sc-duple...
Bo32j15280d 10gbase-zr x2 transceiver 1550nm 80 kilometer singlemode sc-duple...
 

Similar to Folheto BCL 21 e 22

Technical s7889
Technical s7889Technical s7889
Technical s7889
huslen_du
 
Elm323 ds
Elm323 dsElm323 ds
Elm323 ds
sergio
 
Portal Plus Access Control
Portal Plus Access ControlPortal Plus Access Control
Portal Plus Access Control
nimthomas
 
Tracking police man using rf proximity card
Tracking police man using rf proximity cardTracking police man using rf proximity card
Tracking police man using rf proximity card
Albert Jose
 
A zigbee wireless sensor network and multiple way bus communication meduim ca...
A zigbee wireless sensor network and multiple way bus communication meduim ca...A zigbee wireless sensor network and multiple way bus communication meduim ca...
A zigbee wireless sensor network and multiple way bus communication meduim ca...
ranjitha mudhiraj
 

Similar to Folheto BCL 21 e 22 (20)

Technical s7889
Technical s7889Technical s7889
Technical s7889
 
esp32_datasheet_en.pdf
esp32_datasheet_en.pdfesp32_datasheet_en.pdf
esp32_datasheet_en.pdf
 
AD9122 - Dual, 16-Bit, 1200 MSPS, TxDAC
AD9122 - Dual, 16-Bit, 1200 MSPS, TxDACAD9122 - Dual, 16-Bit, 1200 MSPS, TxDAC
AD9122 - Dual, 16-Bit, 1200 MSPS, TxDAC
 
American Fibertek RT-946C-SL Data Sheet
American Fibertek RT-946C-SL Data SheetAmerican Fibertek RT-946C-SL Data Sheet
American Fibertek RT-946C-SL Data Sheet
 
Essential Guide Automation
Essential Guide AutomationEssential Guide Automation
Essential Guide Automation
 
Elm323 ds
Elm323 dsElm323 ds
Elm323 ds
 
Portal Plus Access Control
Portal Plus Access ControlPortal Plus Access Control
Portal Plus Access Control
 
Lam cnv30 brochure
Lam cnv30 brochureLam cnv30 brochure
Lam cnv30 brochure
 
Batch 25(a)
Batch 25(a)Batch 25(a)
Batch 25(a)
 
Project_intership
Project_intershipProject_intership
Project_intership
 
Project_intership
Project_intershipProject_intership
Project_intership
 
Ds xbeeadapters
Ds xbeeadaptersDs xbeeadapters
Ds xbeeadapters
 
S7 200 cable
S7 200 cableS7 200 cable
S7 200 cable
 
RS232 to RS485 converter | GIC India
RS232 to RS485 converter | GIC IndiaRS232 to RS485 converter | GIC India
RS232 to RS485 converter | GIC India
 
Rs232 to rs485 converter
Rs232 to rs485 converterRs232 to rs485 converter
Rs232 to rs485 converter
 
QuickSilver Controls QCI-DS018 QCI-D2-IG8
QuickSilver Controls QCI-DS018 QCI-D2-IG8QuickSilver Controls QCI-DS018 QCI-D2-IG8
QuickSilver Controls QCI-DS018 QCI-D2-IG8
 
Tracking police man using rf proximity card
Tracking police man using rf proximity cardTracking police man using rf proximity card
Tracking police man using rf proximity card
 
American Fibertek RR944C User Manual
American Fibertek RR944C User ManualAmerican Fibertek RR944C User Manual
American Fibertek RR944C User Manual
 
A zigbee wireless sensor network and multiple way bus communication meduim ca...
A zigbee wireless sensor network and multiple way bus communication meduim ca...A zigbee wireless sensor network and multiple way bus communication meduim ca...
A zigbee wireless sensor network and multiple way bus communication meduim ca...
 
Rsf ms 2x_series_catalog
Rsf ms 2x_series_catalogRsf ms 2x_series_catalog
Rsf ms 2x_series_catalog
 

More from Leuze electronic Ltda

More from Leuze electronic Ltda (20)

Cortina de medição CML 700
Cortina de medição CML 700Cortina de medição CML 700
Cortina de medição CML 700
 
Chave Magnética 2 contatos NA
Chave Magnética 2 contatos NAChave Magnética 2 contatos NA
Chave Magnética 2 contatos NA
 
Sistema de Fixação Btx
Sistema de Fixação BtxSistema de Fixação Btx
Sistema de Fixação Btx
 
Folheto nova LSIS 220
Folheto nova LSIS 220Folheto nova LSIS 220
Folheto nova LSIS 220
 
Dados técnicos GS 754
Dados técnicos GS 754Dados técnicos GS 754
Dados técnicos GS 754
 
Folheto BCL 300i
Folheto BCL 300iFolheto BCL 300i
Folheto BCL 300i
 
Folheto BCL 500 i
Folheto BCL 500 iFolheto BCL 500 i
Folheto BCL 500 i
 
Folheto LxS
Folheto LxSFolheto LxS
Folheto LxS
 
Novos produtos para fibra óptica
Novos produtos para fibra ópticaNovos produtos para fibra óptica
Novos produtos para fibra óptica
 
Catálogo - Produtos para Fibra Óptica
Catálogo - Produtos para Fibra ÓpticaCatálogo - Produtos para Fibra Óptica
Catálogo - Produtos para Fibra Óptica
 
LSIS 400i novidades jul 2012
LSIS 400i novidades jul 2012LSIS 400i novidades jul 2012
LSIS 400i novidades jul 2012
 
Cálculo da distância de seguranca
Cálculo da distância de segurancaCálculo da distância de seguranca
Cálculo da distância de seguranca
 
Nova NR 12
Nova NR 12Nova NR 12
Nova NR 12
 
Sensor globalBEAM série 28
Sensor globalBEAM série 28Sensor globalBEAM série 28
Sensor globalBEAM série 28
 
Leitor BCL 300i
Leitor BCL 300iLeitor BCL 300i
Leitor BCL 300i
 
ODSL 30
ODSL 30 ODSL 30
ODSL 30
 
Produtos para NR 12 - segurança no trabalho
Produtos para NR 12 - segurança no trabalhoProdutos para NR 12 - segurança no trabalho
Produtos para NR 12 - segurança no trabalho
 
Chaves magnéticas codificadas
Chaves magnéticas codificadasChaves magnéticas codificadas
Chaves magnéticas codificadas
 
ODSL9
ODSL9 ODSL9
ODSL9
 
Série 318
Série 318Série 318
Série 318
 

Recently uploaded

Easier, Faster, and More Powerful – Alles Neu macht der Mai -Wir durchleuchte...
Easier, Faster, and More Powerful – Alles Neu macht der Mai -Wir durchleuchte...Easier, Faster, and More Powerful – Alles Neu macht der Mai -Wir durchleuchte...
Easier, Faster, and More Powerful – Alles Neu macht der Mai -Wir durchleuchte...
panagenda
 

Recently uploaded (20)

The Value of Certifying Products for FDO _ Paul at FIDO Alliance.pdf
The Value of Certifying Products for FDO _ Paul at FIDO Alliance.pdfThe Value of Certifying Products for FDO _ Paul at FIDO Alliance.pdf
The Value of Certifying Products for FDO _ Paul at FIDO Alliance.pdf
 
AI revolution and Salesforce, Jiří Karpíšek
AI revolution and Salesforce, Jiří KarpíšekAI revolution and Salesforce, Jiří Karpíšek
AI revolution and Salesforce, Jiří Karpíšek
 
WSO2CONMay2024OpenSourceConferenceDebrief.pptx
WSO2CONMay2024OpenSourceConferenceDebrief.pptxWSO2CONMay2024OpenSourceConferenceDebrief.pptx
WSO2CONMay2024OpenSourceConferenceDebrief.pptx
 
How Red Hat Uses FDO in Device Lifecycle _ Costin and Vitaliy at Red Hat.pdf
How Red Hat Uses FDO in Device Lifecycle _ Costin and Vitaliy at Red Hat.pdfHow Red Hat Uses FDO in Device Lifecycle _ Costin and Vitaliy at Red Hat.pdf
How Red Hat Uses FDO in Device Lifecycle _ Costin and Vitaliy at Red Hat.pdf
 
Linux Foundation Edge _ Overview of FDO Software Components _ Randy at Intel.pdf
Linux Foundation Edge _ Overview of FDO Software Components _ Randy at Intel.pdfLinux Foundation Edge _ Overview of FDO Software Components _ Randy at Intel.pdf
Linux Foundation Edge _ Overview of FDO Software Components _ Randy at Intel.pdf
 
WebAssembly is Key to Better LLM Performance
WebAssembly is Key to Better LLM PerformanceWebAssembly is Key to Better LLM Performance
WebAssembly is Key to Better LLM Performance
 
Syngulon - Selection technology May 2024.pdf
Syngulon - Selection technology May 2024.pdfSyngulon - Selection technology May 2024.pdf
Syngulon - Selection technology May 2024.pdf
 
Easier, Faster, and More Powerful – Alles Neu macht der Mai -Wir durchleuchte...
Easier, Faster, and More Powerful – Alles Neu macht der Mai -Wir durchleuchte...Easier, Faster, and More Powerful – Alles Neu macht der Mai -Wir durchleuchte...
Easier, Faster, and More Powerful – Alles Neu macht der Mai -Wir durchleuchte...
 
1111 ChatGPT Prompts PDF Free Download - Prompts for ChatGPT
1111 ChatGPT Prompts PDF Free Download - Prompts for ChatGPT1111 ChatGPT Prompts PDF Free Download - Prompts for ChatGPT
1111 ChatGPT Prompts PDF Free Download - Prompts for ChatGPT
 
Behind the Scenes From the Manager's Chair: Decoding the Secrets of Successfu...
Behind the Scenes From the Manager's Chair: Decoding the Secrets of Successfu...Behind the Scenes From the Manager's Chair: Decoding the Secrets of Successfu...
Behind the Scenes From the Manager's Chair: Decoding the Secrets of Successfu...
 
Using IESVE for Room Loads Analysis - UK & Ireland
Using IESVE for Room Loads Analysis - UK & IrelandUsing IESVE for Room Loads Analysis - UK & Ireland
Using IESVE for Room Loads Analysis - UK & Ireland
 
Intro in Product Management - Коротко про професію продакт менеджера
Intro in Product Management - Коротко про професію продакт менеджераIntro in Product Management - Коротко про професію продакт менеджера
Intro in Product Management - Коротко про професію продакт менеджера
 
Microsoft CSP Briefing Pre-Engagement - Questionnaire
Microsoft CSP Briefing Pre-Engagement - QuestionnaireMicrosoft CSP Briefing Pre-Engagement - Questionnaire
Microsoft CSP Briefing Pre-Engagement - Questionnaire
 
The Metaverse: Are We There Yet?
The  Metaverse:    Are   We  There  Yet?The  Metaverse:    Are   We  There  Yet?
The Metaverse: Are We There Yet?
 
Overview of Hyperledger Foundation
Overview of Hyperledger FoundationOverview of Hyperledger Foundation
Overview of Hyperledger Foundation
 
Speed Wins: From Kafka to APIs in Minutes
Speed Wins: From Kafka to APIs in MinutesSpeed Wins: From Kafka to APIs in Minutes
Speed Wins: From Kafka to APIs in Minutes
 
Simplified FDO Manufacturing Flow with TPMs _ Liam at Infineon.pdf
Simplified FDO Manufacturing Flow with TPMs _ Liam at Infineon.pdfSimplified FDO Manufacturing Flow with TPMs _ Liam at Infineon.pdf
Simplified FDO Manufacturing Flow with TPMs _ Liam at Infineon.pdf
 
IESVE for Early Stage Design and Planning
IESVE for Early Stage Design and PlanningIESVE for Early Stage Design and Planning
IESVE for Early Stage Design and Planning
 
ASRock Industrial FDO Solutions in Action for Industrial Edge AI _ Kenny at A...
ASRock Industrial FDO Solutions in Action for Industrial Edge AI _ Kenny at A...ASRock Industrial FDO Solutions in Action for Industrial Edge AI _ Kenny at A...
ASRock Industrial FDO Solutions in Action for Industrial Edge AI _ Kenny at A...
 
TopCryptoSupers 12thReport OrionX May2024
TopCryptoSupers 12thReport OrionX May2024TopCryptoSupers 12thReport OrionX May2024
TopCryptoSupers 12thReport OrionX May2024
 

Folheto BCL 21 e 22

  • 1. Bar Code Reader Series BCL 20 A flexible reader for a variety of applications P R O D U C T I N F O R M AT I O N
  • 2. The benchmark for flexibility. Laser scanners of the BCL 20 series – as variable as your requirements demand. Whether as a single-line scanner for high-density codes, for example, in analysis automation, with raster optics for reading trays in intra-logistics applications or for inspecting industrial or printed products: the compact bar code readers of the BCL 20 series convince with their high level of flexibility and handling reliabili- ty in all areas. The broad selection of optics also allows the scanners to be used in difficult installation situations and in a wide range of applications, both in networks as well as a standalone solution. Furthermore, the BCL 20 series convinces with its outstanding reading performance through the automatic adaptation of the receiver unit to the reading task on each scan. For an extended reading field, such as that of a bar code reader with focusing function, the new BCL 20 S B is availabe for higher resolution codes. By means of simple online commands it is possible to set the reading task without knowledge of the code. The PC-based BCL-Config tool, which is avail- able for all Leuze bar code readers, is used to access the full function range. Simple online commands make it possible to set the reading task without know- ledge of codes. The BCL Config tool, which can be used for the entire function range, is available for all bar code readers from Leuze electronic Connectivity. Connection to industrial or Ethernet-based networks is now done directly via our MA 200i modular interfacing units.
  • 3.
  • 4. Universally usable – fast integration – simple to operate. The advantages of the bar code reader series BCL 20. Various optics models: Different models with front or lateral beam exit ena- ble optimum use of the installation space. Depending on the code alignment, single-line or raster scanners offer optimised reading capacity High, constant scanning rate up to 1000 scans/s: Considerable increase in the reading reliability through multiple decoding of the read codes, even during fast processes Large depth of field and wide opening angle: High reading capacity with codes having line thicknesses as narrow as 150 μm facilitates front or lateral reading on your goods Integrated multiNet: Up to 31 scanners can be networked in Leuze electronic's own scanner network with minimal installation effort and, if desired, integrated via gateways to the fieldbus level or directly to the host Simple operation: With the aid of online commands such as AutoConfig, the scanner can be set optimally, even without knowledge of the code Easy configuration: The PC-based BCL-Config operating software for all Leuze bar code readers simplifies adjustments and direct communication with the scanner through graphical configuration Blue laser diodes with extended reading field without focus adjustment for higher resolution codes and optimized optics for glossy and cylindrical objects.
  • 5. Interface variants and connector units. Light source gew hgagh Fig.: BCL 21/22 Fig.: BCL 21/22 föjfäää Front beam exit Lateral beam exit BCL 21 BCL 22 multi Net Integrated RS 485 interface and Integrated, freely configurable RS 232 interface RS 232 service interface Standalone operation or daisy chain with up to four Freely configurable or direct connection to the BCL 22 devices Leuze electronic multiNet network 2 switching inputs and 2 switching outputs 1 switching input and 1 switching output Direct connenction to PROFIBUS or other networks via Connect up to 31 scanners to one master in the modular connector units as gateways Leuze electronic multiNet Both systems are available with a 15-pin Sub-D connector or with a system plug for directly connecting to a modular connector unit. Modular connector units BCL 21 BCL 22 MA 22 DC MA 2 MA 4 (D) 1xx MA 4 (D) MA 42 IS/DP-k PROFINET IO/RT, PROFIBUS DP, INTERBUS, Ethernet PROFINET IO/RT, PROFIBUS DP, INTERBUS, Ethernet MA 200i TCP/IP, UDP, IP, EtherCAT, DeviceNet, CANopen TCP/IP, UDP, IP, EtherCAT, DeviceNet, CANopen Mounting devices BT 20 BT 21
  • 6. Technical data Optical data BCL 21 BCL 22 BCL 2x S B Type line or raster scanner (10 lines) line or raster scanner (10 lines) line scanner Light source laser diode, red, approx. 650 nm laser diode, red, approx. 650 nm laser diode, blue, approx. 405 nm Beam exit front or lateral front or lateral front or lateral 800 scans/s (N-/F-optics), 800 scans/s (N-/F-optics), 800 scans/s (B-optics) Scanning rate 1000 scans/s (M-optics) 1000 scans/s (M-optics) Max. usable opening angle approx. 65° approx. 65° approx. 65° Optics models / resolution N-/M-/F-optics, see reading field curves N-/M-/F-optics, see reading field curves N-/M-/F-optics, see reading field curves Read distance see reading field curves see reading field curves see reading field curves Class 2 acc. to EN 60825-1, CDRH Class 2 acc. to EN 60825-1, CDRH Class 2 acc. to EN 60825-1, CDRH Laser safety class (U.S. 21 CFR 1040.10) (U.S. 21 CFR 1040.10) (U.S. 21 CFR 1040.10) Bar code data Code types 2/5l, Code 39, Code 93, Code 128, 2/5l, Code 39, Code 93, Code 128, 2/5l, Code 39, Code 93, Code 128, EAN 128, EAN/UPC, EAN add-on, EAN 128, EAN/UPC, EAN add-on, EAN 128, EAN/UPC, EAN add-on, Codabar (monarch), Pharmacode Codabar (monarch), Pharmacode Codabar (monarch), Pharmacode Number of codes per scan 6 6 6 Number of codes per reading gate 62 62 62 Electrical data Interface RS 485 RS 232 RS 232 Protocols Leuze Standard, multiNet, Ack/Nak Leuze Standard, multiNet, Ack/Nak, Leuze Standard, multiNet, Ack/Nak, 3964, DC 3964, DC Baud rate 110 ... 115200 baud 110 ... 115200 baud 110 ... 115200 baud Data formats 7, 8, 9 data bits 7, 8, 9 data bits 7, 8, 9 data bits none, even, odd parity none, even, odd parity none, even, odd parity 1, 2 stop bit(s) 1, 2 stop bit(s) 1, 2 stop bit(s) Service interface RS 232, 9600 baud, 8 data bits, RS 232, 9600 baud, 8 data bits, RS 232, 9600 baud, 8 data bits, no parity, 1 stop bit no parity, 1 stop bit no parity, 1 stop bit Switching inputs/outputs 1 switching input, 1 switching output 2 switching inputs, 2 switching outputs 2 switching inputs, 2 switching outputs Operating voltage 10 … 30 V DC 10 … 30 V DC 10 … 30 V DC Power consumption max. 3.2 VA max. 3.2 VA max. 3.2 VA Operating and display elements LEDs 1 Pwr/Err LED, 1 Decode LED 1 Pwr/Err LED, 1 Decode LED 1 Pwr/Err LED, 1 Decode LED Mechanical data Protection class IP 54 IP 54 IP 54 Weight 180 g (0.8 m)/260 g (3 m cable) 180 g (0.8 m)/260 g (3 m cable) 180 g (0.8 m)/260 g (3 m cable) Dimensions (W × H × D) 82 × 68 × 28 mm3 82 × 68 × 28 mm3 82 × 68 × 28 mm3 Housing plastic ABS / PC plastic ABS / PC plastic ABS / PC Environmental data Operating temperature range 0 °C … +40 °C 0 °C … +40 °C 0 °C … +40 °C Storage temperature range -20 °C … +60 °C -20 °C … +60 °C -20 °C … +60 °C Air humidity max. 80% rel. humidity, non-condensing max. 80% rel. humidity, non-condensing max. 80% rel. humidity, non-condensing Vibration IEC 60068-2-6, FC test IEC 60068-2-6, FC test IEC 60068-2-6, FC test Shock IEC 60068-2-27, Ea test IEC 60068-2-27, Ea test IEC 60068-2-27, Ea test Electromag. compatibility IEC 61000-6-2, -6-3 IEC 61000-6-2, -6-3 IEC 61000-6-2, -6-3 Certifications CDRH C US CDRH C US CDRH C US
  • 7. Reading field curve, N-optics Reading field curve, SB-optics 60 m = 0,15 90 50 80 m = 0.165 mm m = 0,2 70 40 Reading field width [mm] Reading field width [mm] 60 m = 0.2 mm 30 50 m = 0.3 mm 40 20 30 20 10 m = 0.165 mm m = 0.2 mm m = 0.3 mm 10 m = 0,15 m = 0,2 0 -10 -10 -20 -30 -20 -40 -30 -50 -60 -40 -70 -80 -50 -90 0 20 40 60 80 100 120 140 160 180 200 220 240 -60 0 10 20 30 40 50 60 70 80 90 100 Read distance [mm] Read distance [mm] Reading field curve, M-optics 150 m = 0,2 m = 0,3 Reading field width [mm] 100 m = 0,5 m = 0,8 50 m = 0,5 m = 0,8 m = 0,2 m = 0,3 -50 -100 -150 0 20 40 60 80 100 120 140 160 180 200 220 240 260 Read distance [mm] Reading field curve, F-optics 150 m = 0,5 m = 0,8 100 m = 1,0 Reading field width [mm] 50 m = 0,5 m = 0,8 m = 1,0 -50 -100 -150 0 40 80 120 160 200 240 280 320 360 400 440 480 Read distance [mm]
  • 8. Optoelectronic Sensors Cubic Series Cylindrical Sensors, Mini Sensors, Fiber Optic Amplifiers Measuring Sensors Special Sensors Light Curtains Forked Sensors Double Sheet Monitoring, Splice Detection Inductive Switches Accessories Identification Systems Data Transmission Systems Distance Measurement Bar Code Readers RF-IDent-Systems Modular Interfacing Units Industrial Image Processing Systems Optical Data Transmission Systems Optical Distance Measurement/Positioning Mobile Code Readers Safety Sensors Safety Systems Safety Services Safety Laser Scanners Safety Light Curtains Transceivers and Multiple Light Beam Safety Devices Single Light Beam Safety Devices AS-i-Safety Product Range Safety Sensor Technology for PROFIBUS DP Safety Switches, Safety Locking Devices and Safety Command Devices Safety Relays Sensor Accessories and Signal Devices Safety Engineering Software Machine Safety Services Leuze electronic GmbH + Co. KG en 02-2012/06 50031292 In der Braike 1 D-73277 Owen / Germany Phone +49 7021 573-0 Fax +49 7021 573-199 info@leuze.de www.leuze.com