220 kv gss renwal ppt

  1. 1. 220KV GSS , RENWAL , JAIPUR Presented By:- ANIL KUMAR KUMAWAT IV YEAR EE A PRESENTATION ON Session: - 2014-2015 Submitted to:- Mr. AMIT PANDAY Mr. GAURAV SRIVASTAVA Department of Electrical Engineering Poornima Institute of Engineering & Technology ISI-2, RIICO Institutional Area, Goner Road, Sitapura, Jaipur-302022
  2. 2. OUTLINE OF PRESENTATION  GENERAL DISCUSSION ON SUB STATION  FEEDERS  Equipments :-  Lightning arrester (L.A.)  Capacitive voltage transformer Wave trap (PLCC)  Isolator  Instrument transformers :-C.T. & P.T.  Circuit breaker :- definition & types  Bus bar  Power transformer:-introduction & main parts  Protective relays :- introduction & Buchhloz relay  SUMMARY
  3. 3. WHY WE NEED GSS ???  Improvement of Reliability  Improvement of economics  Improvement of efficiency  Imrovement of power quality  Improvement of security & safety  Controller of entire power system
  4. 4. SUBSTATION Part of Electricity Generation Transmission of Electricity Distribution of Electricity Voltage is Transformed High to Low or vice-versa using TRANSFORMEr Ex.-400kV/220kV substation 220kV/132kV substation 132kV/33kV substation 33kV/11kV substation 33kV/.4kV substation
  5. 5. 220kV GSS RENWAL It is devided into two parts:- A. Panel Section  Control Panel Section  Relay and Protection Panel Section B. Switch Yard  220kV Section  132kV section  33kV section C. Battery Room (Extra)
  6. 6. A. Panel Section  It is a room which contains all types of panels.  It has two sections:-  Control Panel Section It contain panels related to controlling of instruments. E.g.:- feeder panel, X-mer panel, etc.  Relay And Protection Panel Section It contains panels related to relay systems and protection systems. E.g.:- Relay panel, line protection panel, etc.
  7. 7. B. Switch Yard It is the field where components used in controlling supply and measuring supply(incoming and outgoing) are placed. Some of these components are:-  C.Bs  Isolators  C.Ts  P.Ts  L.As  X-mers, etc.
  8. 8. 220 kV Incoming from HEERAPURA & REENGAS LIGHTNING ARRESTORS CVT WAVE TRAP CT CIRCUIT BREAKER LINE ISOLATOR BUS ISOLATOR CT PT with BUS ISOLATOR CB LA with EARTH SWITCH LA ISOLATOR CT 132 kV OUTPUT ISOLATORS with EARTH SWITCH CAPACITOR BANK MAIN X-MER PT with BUS ISOLATOR CB EQUIPMENTS FLOW
  9. 9. 220 kV GSS RENWAL HEERAPURA-220 kV REENGAS-220 kV FEEDERS Hingoniya-132 kV Champapura-132 kV Khachriyavas-132 kV Danta-132kV Dungari-33 kV Pachkodiya-33 kV Renwal-33 kV Minda-33 kV Badhal-33 kV
  10. 10. EQUIPMENTS – LIGHTENING ARRESTER  Protect the Insulation & Conductors of the system from damaging effect of LIGHTNING
  11. 11. CAPACITIVE VOLTAGE TRANSFORMER step down extra high voltage signals. provide a low voltage signal. for MEASUREMENT of voltage. to operate a protective relay.
  12. 12. WAVE TRAP (PLCC) POWER LINE CARRIER COMMUNICATION exchange of data and transfer of messages between substations. WAVE TRAP-TRAPPING the unwanted waves.
  13. 13. ISOLATORS  Used for completety DE-ENERGISED the electrical ckt. for SERVICE or MAINTENANCE.  Separate the circuit at NO LOAD CONDITION.
  14. 14. INSTRUMENT TRANSFORMERS Instrument transformers are used for measurement and protective applications together with equipments such as meters & relays Types- - CURRENT TRANSFORMER - POTENTIAL TRANSFORMER
  15. 15. CIRCUIT BREAKER Automatically Operated ELECTRICAL SWITCH. Designed to protect the ckt. from overload or SHORT CKT. Separate Healthy & Faulty Section of ckt. Operate at ON LOAD Condition.
  16. 16. TYPES OF CIRCUIT BREAKERS SULPAR HEXAFLUORIDE CIRCUIT BREAKER (SF6) Sulpharhexa fluoride (SF6) gas is used as the arc quenching medium . The SF6 is an electronegative gas and has a strong tendency to absorb free electrons. Circuit breakers have been developed for voltage 115KV to 230KV , power rating10 MVA VACUUM CIRCUIT BREAKERS Vacuum circuit breakers are circuit breakers which are used to protect medium and high voltage circuits from dangerous electrical situations OIL CIRCUIT BREAKER A high-voltage circuit breaker in which the arc is drawn in oil to dissipate the heat and extinguish the arc; the intense heat of the arc decomposes the oil . AIR-BLAST CIRCUIT BREAKER Fast operations ,suitability for repeated operation , auto reclosure , unit type multi break constructions ,simple assembly , modest maintenance are some of the main features of air blast circuit breakers. A compressors plant necessary to maintain high air pressure in the air receiver.
  17. 17. BUS BAR  A bus bar is a conducting bar that carries heavy currents to supply several electric circuits.  Made up of copper rod or thin walled tubes. TYPES:- - MAIN BUS BAR. - AUXILIARY BUS BAR
  18. 18. POWER TRANSFORMER A Static Device. Transfer Power from One ckt. to Another ckt. NO Change in FREQUENCY. Principle-FARADAY ’s LAW of ELECTROMAGNETIC INDUCTION. Types- 1. STEP UP X-MER:: O/P Voltage > I/P Voltage. 2. STEP DOWN X-MER :: O/P Voltage < I/P Voltage.
  19. 19. FIGURE-POWER TRANSFORMER
  20. 20. PARTS OF TRANSFORMER  core  Winding(H.V winding, L.V winding, tertiary winding)  X-MER OILS  PRESSURE RELIEF VALVE  BREATHER  Conservator  RADIATER  Tap changer  Tank
  21. 21. Protective Relay is a sensing device and is designed to detect operating conditions on an electric circuit. It trips the circuit breaker when fault is detected. PROTECTIVE RELAYS
  22. 22. BUCHHOLZ RELAY  A gas actuated relay.  it is installed in b/w the conservatorand the main tank.  PRINCIPLE:- Whenever a fault occurs inside the transformers, the oil of the tank gets overheated and gases are generated.The heat generated by the high local current causes the transformer oil to decompose and produce gas which can be used to detect the faults.
  23. 23. BATTERY ROOM  DC battery shell be installed in the power house for  Protection.  Emergency power.  Alarm and indication.
  24. 24. SUMMARY OF EQUIPMENTs TRANSFORMERS Also known as the heart of substations. These are used to reduce the voltages at appropriate levels CURRENT VOLTAGE TRANSFORMERS It is a used in power systems to step down extra high voltage signals and provide a low voltage signal, for measurement or to operate a protective relay WAVETRAP Traps the high frequency signals LIGHTINING ARRESTER Used for protecting the equipment from surge voltages CIRCUIT BREAKER used to protect the equipment by opening the circuit for over current and over voltages ISOLATORS Used for maintenance of the circuit in no load condition RELAY Used to sense the faults
  25. 25. QUERIES ???

×