SlideShare a Scribd company logo
1 of 25
Project Supervisor : GMA Ehsan ur Rahman
Co- Supervisor : Dr. M S Rahman
Project members :
 Md. Mahmud - ul – Hasan ( 042432 )
 Md. Kafiul Islam ( 042460 )
 Mehedi Azad Shawon ( 042464 )
Basically our project is on Bio-medical
Engineering. We were interested on it as
there are a lot of opportunity to work in
this field.
1.To make the system EMBEDDED for blood
pressure monitoring
2. Automatically blood pressure will be taken
3. Analyze the data & detect SYSTOLE, DIASTOLE
& PULSE-RATE & store
4. Result will be shown in LCD monitor
5. Export the result to the server using Ethernet
6. To develop a new effective method for detecting
systole , diastole & pulse rate
.
7. Reduce workload of Medical personals
8. Help to keep flawless and regular data of
patient’s progress.
9. Give better medical facilities through the Govt.
Hospitals, Clinics.
1. Needs skilled hand to detect the sound.
2. It always needs some other person to measure.
3. Lower accuracy in the DBPMs
4. Not programmable
5. Even in case of digital one , it is very costly.
6. Data can only be stored but can not be exported
for further processed.
Higher Accuracy than analog one
Programmable
data can be stored and use later
Graphical representation
low cost since we are locally making it
1. Blood pressure
2. Systole & diastole
3. Pulse rate
 Blood Pressure can be defined as the
lateral pressure exerted by blood on the
vessel walls while flowing through it.
Range of BP:
In case of adult males, the average
Systolic Pressure is 110-145mmHg and
average Diastolic Pressure is 70-90 mmHg.
The term blood pressure usually refers to arterial
pressure and is conventionally recorded as two values:
systolic pressure, which is the arterial pressure
measured during systole (the ejection phase of the
cardiac cycle) and
diastolic pressure, which is the arterial pressure
measured during diastole (the filling phase of the
cardiac cycle).
The height of Systolic Pressure indicates
i) the extent of work done by Heart,
ii) the force with which the heart is working,
iii) the degree of pressure which the arterial walls have to
withstand.
On the other hand, increased Diastolic Pressure indicates that
the Heart is approaching towards its failure.
Altogether, the height of Blood Pressure gives correct
information about the state of Circulatory System as a whole and
also about the functional conditions of the tissue, cells and
organs.
1. Give cuff pressure up to certain level
2.Release the pressure slowly
3. Collect data & detect systole & diastole
4. Fast release of air pressure
Start
Close Main Air Vent & start Pump
Read ADC
Stop Pumping
Read & Store data from ADC
Open main air vent & collect
data
Switch On?
Cuff Press.
>=190mm Hg?
Cuff Press.
<50mm Hg?
Calculate Systole,
Diastole & Pulse Rate
Display BP
Stop
Y
N Y
N
Y
N
BufferBuffer
Pressure
Sensor
GND
Vcc
V +
V -
Adder
To ADC
Make Zero
GND
GND
Salient Features:
Advanced RISC architecture with 32 x 8 general
purpose working Registers.
Low power AVR 8-bit, 28 leads mc with built-in ADC.
23 programmable I/O lines.
6 single ended ADC input channel each with 10-bit
resolution.
Built-in Analog comparator.
 Max speed of 16 MHz .
8KB of Flash memory , 512 Bytes of EEPROM & 1KB
Internal SRAM
Making ISP Circuit for loading the program from PC
through parallel port.
Serial communication between pc & uc
Development of the theory & program for detecting
systole & diastole.
Interfacing between pressure sensor & uc
 Power supply for our whole system.
+5 Volt  Control ckt & motor.
+6 Volt  Main Air Vent Solenoid.
+12 Volt  Relay Driving.
+10V~16V  Pressure Sensor
The last one for excitation voltage of Pressure
Sensor is variable & must be a very good one
which is reliable & stable or ripple free.
1.To detect the pulse rate
2.Memory shortage
3.deviation in o/p due to noise in op-amp
1.replacing atmega8 by LPC2148 (32 bit ARM7
uc,40kB SRAM,512KB flash)
2.etharnet connection
3.LCD & Keyboard interface
4. to make a compact form of the whole system as a
market product.
Thank you all !!!!!
Questions
??

More Related Content

What's hot

Design and Implementation of programmable Cardiac Pacemaker Using VHDL
Design and Implementation of programmable Cardiac Pacemaker Using VHDLDesign and Implementation of programmable Cardiac Pacemaker Using VHDL
Design and Implementation of programmable Cardiac Pacemaker Using VHDL
IJERA Editor
 
Biotelemetry
BiotelemetryBiotelemetry
Biotelemetry
Samuely
 
Diagnostic procedures
Diagnostic proceduresDiagnostic procedures
Diagnostic procedures
tpolk12
 
HEART ATTACK DETECTION SYSTEM
HEART ATTACK DETECTION SYSTEMHEART ATTACK DETECTION SYSTEM
HEART ATTACK DETECTION SYSTEM
achuthanandanarmeta
 

What's hot (20)

The Holter Device and the Event Monitor
The Holter Device and the Event MonitorThe Holter Device and the Event Monitor
The Holter Device and the Event Monitor
 
Design and Implementation of programmable Cardiac Pacemaker Using VHDL
Design and Implementation of programmable Cardiac Pacemaker Using VHDLDesign and Implementation of programmable Cardiac Pacemaker Using VHDL
Design and Implementation of programmable Cardiac Pacemaker Using VHDL
 
Biotelemetry
BiotelemetryBiotelemetry
Biotelemetry
 
Multipara monitor
Multipara monitorMultipara monitor
Multipara monitor
 
Holter,ilr,elr
Holter,ilr,elrHolter,ilr,elr
Holter,ilr,elr
 
Pacemaker | Implantable Cardiac Devices For Heart Failures
Pacemaker | Implantable Cardiac Devices For Heart FailuresPacemaker | Implantable Cardiac Devices For Heart Failures
Pacemaker | Implantable Cardiac Devices For Heart Failures
 
Postoperative cardiovascular complications
Postoperative cardiovascular complicationsPostoperative cardiovascular complications
Postoperative cardiovascular complications
 
What Information Does an ECG Provide?
What Information Does an ECG Provide? What Information Does an ECG Provide?
What Information Does an ECG Provide?
 
Holter monitoring
Holter monitoringHolter monitoring
Holter monitoring
 
Detection of Arrhythmia
Detection of ArrhythmiaDetection of Arrhythmia
Detection of Arrhythmia
 
Mini project
Mini projectMini project
Mini project
 
Pulse detector
Pulse detectorPulse detector
Pulse detector
 
Pacemakers
PacemakersPacemakers
Pacemakers
 
Cardiac pacemaker
Cardiac pacemakerCardiac pacemaker
Cardiac pacemaker
 
Diagnostic procedures
Diagnostic proceduresDiagnostic procedures
Diagnostic procedures
 
HEART ATTACK DETECTION SYSTEM
HEART ATTACK DETECTION SYSTEMHEART ATTACK DETECTION SYSTEM
HEART ATTACK DETECTION SYSTEM
 
Holter monitoring
Holter monitoringHolter monitoring
Holter monitoring
 
Speech on Pacemaker
Speech on PacemakerSpeech on Pacemaker
Speech on Pacemaker
 
Design an impedance plethysmography system for measuring limb
Design an impedance plethysmography system for measuring limbDesign an impedance plethysmography system for measuring limb
Design an impedance plethysmography system for measuring limb
 
Holter monitor and information does it provide
Holter monitor and information does it provideHolter monitor and information does it provide
Holter monitor and information does it provide
 

Similar to Presentation on Blood Pressure Monitoring as part of Final Year Project (Part-1) in 2008 at IUT

Patient monitoring system to monitor physiological parameters.pptx
Patient  monitoring system to monitor physiological parameters.pptxPatient  monitoring system to monitor physiological parameters.pptx
Patient monitoring system to monitor physiological parameters.pptx
RevathiJ10
 
Final Project Slides Buchheit Harings Hussein
Final Project Slides Buchheit Harings HusseinFinal Project Slides Buchheit Harings Hussein
Final Project Slides Buchheit Harings Hussein
Scott Buchheit
 

Similar to Presentation on Blood Pressure Monitoring as part of Final Year Project (Part-1) in 2008 at IUT (20)

Body Temperature & Blood Pressure Remote Monitoring
Body Temperature & Blood Pressure Remote MonitoringBody Temperature & Blood Pressure Remote Monitoring
Body Temperature & Blood Pressure Remote Monitoring
 
Report
ReportReport
Report
 
Zl embd045 wireless telemedia system based on arm and web server
Zl embd045 wireless telemedia system based on arm and web serverZl embd045 wireless telemedia system based on arm and web server
Zl embd045 wireless telemedia system based on arm and web server
 
cardiac output monitoring
cardiac output monitoringcardiac output monitoring
cardiac output monitoring
 
Home Care Heart Diagnosis and Measurement of Biological Signals Using Intelli...
Home Care Heart Diagnosis and Measurement of Biological Signals Using Intelli...Home Care Heart Diagnosis and Measurement of Biological Signals Using Intelli...
Home Care Heart Diagnosis and Measurement of Biological Signals Using Intelli...
 
Patient monitoring system to monitor physiological parameters.pptx
Patient  monitoring system to monitor physiological parameters.pptxPatient  monitoring system to monitor physiological parameters.pptx
Patient monitoring system to monitor physiological parameters.pptx
 
An Implementation of Embedded System in Patient Monitoring System
An Implementation of Embedded System in Patient Monitoring SystemAn Implementation of Embedded System in Patient Monitoring System
An Implementation of Embedded System in Patient Monitoring System
 
An Efficient Design and FPGA Implementation of JPEG Encoder using Verilog HDL
An Efficient Design and FPGA Implementation of JPEG Encoder using Verilog HDLAn Efficient Design and FPGA Implementation of JPEG Encoder using Verilog HDL
An Efficient Design and FPGA Implementation of JPEG Encoder using Verilog HDL
 
CARDIO VASCULAR ALERTING SYSTEM FOR POST – OP CABG PATIENTS
CARDIO VASCULAR ALERTING SYSTEM FOR POST – OP CABG PATIENTSCARDIO VASCULAR ALERTING SYSTEM FOR POST – OP CABG PATIENTS
CARDIO VASCULAR ALERTING SYSTEM FOR POST – OP CABG PATIENTS
 
IJET-V3I1P26
IJET-V3I1P26IJET-V3I1P26
IJET-V3I1P26
 
Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)
 
Hcl hh20
Hcl hh20Hcl hh20
Hcl hh20
 
Biomedical Instrumentation
Biomedical InstrumentationBiomedical Instrumentation
Biomedical Instrumentation
 
Picco application note 2 (1)
Picco application note 2 (1)Picco application note 2 (1)
Picco application note 2 (1)
 
4. 7770 8115-1-pb
4. 7770 8115-1-pb4. 7770 8115-1-pb
4. 7770 8115-1-pb
 
Non invasive
Non invasiveNon invasive
Non invasive
 
IRJET-Intelligent ICU Monitoring System
IRJET-Intelligent ICU Monitoring SystemIRJET-Intelligent ICU Monitoring System
IRJET-Intelligent ICU Monitoring System
 
Icasert 2019 pid_230_revised
Icasert 2019 pid_230_revisedIcasert 2019 pid_230_revised
Icasert 2019 pid_230_revised
 
Report on Automatic Heart Rate monitoring using Arduino Uno
Report on Automatic Heart Rate monitoring using Arduino UnoReport on Automatic Heart Rate monitoring using Arduino Uno
Report on Automatic Heart Rate monitoring using Arduino Uno
 
Final Project Slides Buchheit Harings Hussein
Final Project Slides Buchheit Harings HusseinFinal Project Slides Buchheit Harings Hussein
Final Project Slides Buchheit Harings Hussein
 

More from Md Kafiul Islam

More from Md Kafiul Islam (20)

EEE400 1st Trimester Progress Presentation on Sleep Disorder Classification
EEE400 1st Trimester Progress Presentation on Sleep Disorder ClassificationEEE400 1st Trimester Progress Presentation on Sleep Disorder Classification
EEE400 1st Trimester Progress Presentation on Sleep Disorder Classification
 
EEE400 1st Trimester Progress Presentation on EEG based Neuro-Marketing
EEE400 1st Trimester Progress Presentation on EEG based Neuro-MarketingEEE400 1st Trimester Progress Presentation on EEG based Neuro-Marketing
EEE400 1st Trimester Progress Presentation on EEG based Neuro-Marketing
 
Invited talk at IBRO UIU EEG Signal Processing
Invited talk at IBRO UIU EEG Signal ProcessingInvited talk at IBRO UIU EEG Signal Processing
Invited talk at IBRO UIU EEG Signal Processing
 
Study of smart phone sensor based fall detection
Study of smart phone sensor based fall detectionStudy of smart phone sensor based fall detection
Study of smart phone sensor based fall detection
 
Presentation slides on Child Tracking System
Presentation slides on Child Tracking SystemPresentation slides on Child Tracking System
Presentation slides on Child Tracking System
 
TENSYMP presentation
TENSYMP presentationTENSYMP presentation
TENSYMP presentation
 
Poster eog controlled wheelchair new
Poster eog controlled wheelchair newPoster eog controlled wheelchair new
Poster eog controlled wheelchair new
 
Digitization of Infusion Pump
Digitization of Infusion PumpDigitization of Infusion Pump
Digitization of Infusion Pump
 
Development of a low cost pc-based single-channel eeg monitoring system
Development of a low cost pc-based single-channel eeg monitoring systemDevelopment of a low cost pc-based single-channel eeg monitoring system
Development of a low cost pc-based single-channel eeg monitoring system
 
EMG classification using ANN
EMG classification using ANNEMG classification using ANN
EMG classification using ANN
 
Real-time Vein Imaging
Real-time Vein ImagingReal-time Vein Imaging
Real-time Vein Imaging
 
ECG Classification using SVM
ECG Classification using SVMECG Classification using SVM
ECG Classification using SVM
 
ICDPR@SG 2020 PID_A304_presentation
ICDPR@SG 2020 PID_A304_presentationICDPR@SG 2020 PID_A304_presentation
ICDPR@SG 2020 PID_A304_presentation
 
EMG controlled Prosthetic Arm
EMG controlled Prosthetic ArmEMG controlled Prosthetic Arm
EMG controlled Prosthetic Arm
 
Motion Artifact in Ambulatory EEG
Motion Artifact in Ambulatory EEGMotion Artifact in Ambulatory EEG
Motion Artifact in Ambulatory EEG
 
Exploring smartphone sensors
Exploring smartphone sensorsExploring smartphone sensors
Exploring smartphone sensors
 
Senior Project Student's Presentation on Design of EMG Signal Recording System
Senior Project Student's Presentation on Design of EMG Signal Recording SystemSenior Project Student's Presentation on Design of EMG Signal Recording System
Senior Project Student's Presentation on Design of EMG Signal Recording System
 
Senior Project Student's Presentation on Body Temperature Monitoring
Senior Project Student's Presentation on Body Temperature MonitoringSenior Project Student's Presentation on Body Temperature Monitoring
Senior Project Student's Presentation on Body Temperature Monitoring
 
Senior Project Students' Presentation on ECG Monitoring
Senior Project Students' Presentation on ECG MonitoringSenior Project Students' Presentation on ECG Monitoring
Senior Project Students' Presentation on ECG Monitoring
 
EEG guest lecture_iub_eee541
EEG guest lecture_iub_eee541EEG guest lecture_iub_eee541
EEG guest lecture_iub_eee541
 

Recently uploaded

Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak HamilCara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Kandungan 087776558899
 
Digital Communication Essentials: DPCM, DM, and ADM .pptx
Digital Communication Essentials: DPCM, DM, and ADM .pptxDigital Communication Essentials: DPCM, DM, and ADM .pptx
Digital Communication Essentials: DPCM, DM, and ADM .pptx
pritamlangde
 
scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...
scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...
scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...
HenryBriggs2
 
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
AldoGarca30
 

Recently uploaded (20)

Work-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptxWork-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptx
 
Moment Distribution Method For Btech Civil
Moment Distribution Method For Btech CivilMoment Distribution Method For Btech Civil
Moment Distribution Method For Btech Civil
 
Design For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the startDesign For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the start
 
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptxOrlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.ppt
 
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
COST-EFFETIVE  and Energy Efficient BUILDINGS ptxCOST-EFFETIVE  and Energy Efficient BUILDINGS ptx
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
 
Introduction to Data Visualization,Matplotlib.pdf
Introduction to Data Visualization,Matplotlib.pdfIntroduction to Data Visualization,Matplotlib.pdf
Introduction to Data Visualization,Matplotlib.pdf
 
Jaipur ❤CALL GIRL 0000000000❤CALL GIRLS IN Jaipur ESCORT SERVICE❤CALL GIRL IN...
Jaipur ❤CALL GIRL 0000000000❤CALL GIRLS IN Jaipur ESCORT SERVICE❤CALL GIRL IN...Jaipur ❤CALL GIRL 0000000000❤CALL GIRLS IN Jaipur ESCORT SERVICE❤CALL GIRL IN...
Jaipur ❤CALL GIRL 0000000000❤CALL GIRLS IN Jaipur ESCORT SERVICE❤CALL GIRL IN...
 
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
 
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKARHAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
 
data_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfdata_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdf
 
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak HamilCara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
 
Digital Communication Essentials: DPCM, DM, and ADM .pptx
Digital Communication Essentials: DPCM, DM, and ADM .pptxDigital Communication Essentials: DPCM, DM, and ADM .pptx
Digital Communication Essentials: DPCM, DM, and ADM .pptx
 
Thermal Engineering Unit - I & II . ppt
Thermal Engineering  Unit - I & II . pptThermal Engineering  Unit - I & II . ppt
Thermal Engineering Unit - I & II . ppt
 
Unleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leapUnleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leap
 
scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...
scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...
scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...
 
💚Trustworthy Call Girls Pune Call Girls Service Just Call 🍑👄6378878445 🍑👄 Top...
💚Trustworthy Call Girls Pune Call Girls Service Just Call 🍑👄6378878445 🍑👄 Top...💚Trustworthy Call Girls Pune Call Girls Service Just Call 🍑👄6378878445 🍑👄 Top...
💚Trustworthy Call Girls Pune Call Girls Service Just Call 🍑👄6378878445 🍑👄 Top...
 
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
 
School management system project Report.pdf
School management system project Report.pdfSchool management system project Report.pdf
School management system project Report.pdf
 
Employee leave management system project.
Employee leave management system project.Employee leave management system project.
Employee leave management system project.
 

Presentation on Blood Pressure Monitoring as part of Final Year Project (Part-1) in 2008 at IUT

  • 1.
  • 2. Project Supervisor : GMA Ehsan ur Rahman Co- Supervisor : Dr. M S Rahman Project members :  Md. Mahmud - ul – Hasan ( 042432 )  Md. Kafiul Islam ( 042460 )  Mehedi Azad Shawon ( 042464 )
  • 3. Basically our project is on Bio-medical Engineering. We were interested on it as there are a lot of opportunity to work in this field.
  • 4. 1.To make the system EMBEDDED for blood pressure monitoring 2. Automatically blood pressure will be taken 3. Analyze the data & detect SYSTOLE, DIASTOLE & PULSE-RATE & store 4. Result will be shown in LCD monitor 5. Export the result to the server using Ethernet 6. To develop a new effective method for detecting systole , diastole & pulse rate
  • 5. . 7. Reduce workload of Medical personals 8. Help to keep flawless and regular data of patient’s progress. 9. Give better medical facilities through the Govt. Hospitals, Clinics.
  • 6. 1. Needs skilled hand to detect the sound. 2. It always needs some other person to measure. 3. Lower accuracy in the DBPMs 4. Not programmable 5. Even in case of digital one , it is very costly. 6. Data can only be stored but can not be exported for further processed.
  • 7. Higher Accuracy than analog one Programmable data can be stored and use later Graphical representation low cost since we are locally making it
  • 8.
  • 9. 1. Blood pressure 2. Systole & diastole 3. Pulse rate
  • 10.  Blood Pressure can be defined as the lateral pressure exerted by blood on the vessel walls while flowing through it. Range of BP: In case of adult males, the average Systolic Pressure is 110-145mmHg and average Diastolic Pressure is 70-90 mmHg.
  • 11. The term blood pressure usually refers to arterial pressure and is conventionally recorded as two values: systolic pressure, which is the arterial pressure measured during systole (the ejection phase of the cardiac cycle) and diastolic pressure, which is the arterial pressure measured during diastole (the filling phase of the cardiac cycle).
  • 12. The height of Systolic Pressure indicates i) the extent of work done by Heart, ii) the force with which the heart is working, iii) the degree of pressure which the arterial walls have to withstand. On the other hand, increased Diastolic Pressure indicates that the Heart is approaching towards its failure. Altogether, the height of Blood Pressure gives correct information about the state of Circulatory System as a whole and also about the functional conditions of the tissue, cells and organs.
  • 13. 1. Give cuff pressure up to certain level 2.Release the pressure slowly 3. Collect data & detect systole & diastole 4. Fast release of air pressure
  • 14.
  • 15.
  • 16.
  • 17. Start Close Main Air Vent & start Pump Read ADC Stop Pumping Read & Store data from ADC Open main air vent & collect data Switch On? Cuff Press. >=190mm Hg? Cuff Press. <50mm Hg? Calculate Systole, Diastole & Pulse Rate Display BP Stop Y N Y N Y N
  • 19. Salient Features: Advanced RISC architecture with 32 x 8 general purpose working Registers. Low power AVR 8-bit, 28 leads mc with built-in ADC. 23 programmable I/O lines. 6 single ended ADC input channel each with 10-bit resolution. Built-in Analog comparator.  Max speed of 16 MHz . 8KB of Flash memory , 512 Bytes of EEPROM & 1KB Internal SRAM
  • 20. Making ISP Circuit for loading the program from PC through parallel port. Serial communication between pc & uc Development of the theory & program for detecting systole & diastole. Interfacing between pressure sensor & uc  Power supply for our whole system.
  • 21. +5 Volt  Control ckt & motor. +6 Volt  Main Air Vent Solenoid. +12 Volt  Relay Driving. +10V~16V  Pressure Sensor The last one for excitation voltage of Pressure Sensor is variable & must be a very good one which is reliable & stable or ripple free.
  • 22. 1.To detect the pulse rate 2.Memory shortage 3.deviation in o/p due to noise in op-amp
  • 23. 1.replacing atmega8 by LPC2148 (32 bit ARM7 uc,40kB SRAM,512KB flash) 2.etharnet connection 3.LCD & Keyboard interface 4. to make a compact form of the whole system as a market product.
  • 24. Thank you all !!!!!