Solar subsurface pump system
solarpump




Solar Energy

Solar Heat

Mounting System




                               Solar subsurface pump system
                               solarpump 300, 450, 600 and 1000




english
SOLAR SUBSURFACE PUMP SYSTEM                                                                                     solar|pump                                         The system comprises four performance classes.                                                                    * PV module under STC: AM 1.5; E= 1000 W/m²




                                                                                                                                                                    How it works:                                  Example 1                                              Example 2
The solar subsurface pump system is used to deliver ground water independently and off-line. With its modular construction,                                                                                        You desire a pump system with a delivery volume        You desire a pump system with a delivery capacity of at least
                                                                                                                                                                    - If the delivery head is not listed in        of at least 3,000 litres per hour and a delivery       800 litres per hour and a delivery head of 80 metres.
the individual components can be adapted to meet all requirements and application areas.
                                                                                                                                                                      the tables, round it up to the next          head of 15 metres.
                                                                                                                                                                      higher available value.                                                                             >> The delivery head “80 m” is not listed in any of the tables.
                                                                                                                                                                    - Determining values not listed in             >> Starting with the smallest solar pump, look for     Therefore always round up to the next higher available delivery
Properties                                                                                                                                                            the table by interpolation or                the value “15 m” in the tables and check the asso-     head, in this case “100 m”. Starting with the smallest solar pump,
                                                                                                                                                                      extrapolation is not permitted.              ciated delivery flow rate: The value of “3,000 litres   look for the value “100 m” in the tables and check the associated
                                                                                                                                                                    - If the delivery head is lower with           per hour” is first met by the solarpump 500, and        delivery flow rate: solarpump 500 equates to 520 litres per hour,
• Module surface area: 2,5 – 7,5 m²                                                                                                                                   the same pump, this does not                 in this case, with 4,500 litres per hour, exceeded.    solarpump 1000 970 litres per hour.
• High stability (calculated according to DIN 1055/ EC 1)
                                              1055                                                                                                                    result in a higher delivery volume.
                                                                                                                                                                    - Only the same delivery volume                The two search values of 3,000 litres per hour         The two search values of 800 litres per hour and a delivery head
• Continuously adjustable irradiation angle and azimuth                                                                                                               may be planned.                              and a delivery head of 15 metres are met by the        of 80 metres are met by configuration solarpump 1000 SQF-1.2-2
• Weight optimisation and prevention of rust formation through use of aluminium / steel                                                                                                                            configuration solarpump SQF-5A-6.

• PV module installation with proven aluminium profiles from the in-house Quick-Line assembly system
• Cable conduits and control assembly in mast, as required with protection against unauthorised access
• Space-saving installation (modules can be sited above the well)                                                                                                     1         solar|pump                           300                                                       Delivery head         Pump capacity*           Pump type
• Pump with run-dry protection, overvoltage and undervoltage protection as well as overload protection,                                                                                                                                                                        15 m                  1.140 Liter/h            SQF-1.2-2
     overtemperature protection, maximum power point tracking, wide input voltage range                                                                                   • MPP output: 312 Wp
                                                                                                                                                                                                                                                                               30 m                  540 Liter/h              SQF-0.6-2
• Simple system installation with factory pre-assembly                                                                                                                    • 1 mast Type A
• Easy installation and maintenance of pump                                                                                                                               • 1 module mount                                                                                     50 m                  530 Liter/h              SQF-0.6-2

• Installation on concrete foundations                                                                                                                                    • 2 modules                                                                                          75 m                  500 Liter/h              SQF-0.6-2
• Optional: upgrade with energy storage system                                                                                                                            • 2 strings




Structure                                                                                                                                                             2         solar|pump                           450                                                       Delivery head         Pump capacity*           Pump type

The system comprises the following components:                                                                                                                                                                                                                                 15 m                  4.500 Liter/h            SQF-5A-6
                                                                                                    b
                                                                                                                                                                          • MPP output: 468 Wp
                                                                                                                                                                                                                                                                               30 m                  2.300 Liter/h            SQF-2.5-2
 a    Mast:
      Mast: two design types – mast A for one module mount                                                                                                                • 1 mast Type A
      and mast B for two module mounts                                                                                                                                    • 1 module mount                                                                                     50 m                  1.090 Liter/h            SQF-1.2-2

                                                                                                                                                                          • 3 modules                                                                                          75 m                  1.050 Liter/h            SQF-1.2-2
 b    Module mount with modules: two design types
                        modules:                                                                                                                                          • 3 strings
                                                                                f                                                                                                                                                                                              100 m                 520 Liter/h              SQF-0.6-2
      for 2 or 3 photovoltaic modules                                                                        a

                                                                                                                                     c
 c    Pump:
      Pump: Grundfos SQ-Flex series submersible pump complete
      with d polyethylene pipe DN 30 (PE-HD drinking water,
                                                                         e
                                                                                                                                                                      3         solar|pump                           600                                                       Delivery head         Pump capacity*           Pump type

      outside diameter: 32 mm, wall thickness: 2.4 mm),                                                                                                                                                                                                                        15 m                  5.600 Liter/h            SQF-5A-6
 e    submarine cable, stainless steel support cable (cut to length),                                                                                                     • MPP output: 624 Wp
                                                                                                                                                                                                                                                                               30 m                  3.000 Liter/h            SQF-3A-10
      screw connections, electrical connecting terminals, shrink                                                                                                          • 1 mast Type B
      sleeve set                                                                               d                                                                          • 2 module mount                                                                                     50 m                  2.100 Liter/h            SQF-2.5-2

 f    Disconnector unit (mp-tec) incl. fuse                                                                                                                               • 4 modules                                                                                          100 m                 970 Liter/h              SQF-1.2-2
      Optional: at extra charge, delivery with Grundfos CU200                                                                                                             • 2 strings
      pump control unit incl. float switch



 PV MODULE – Thin film module (example)                                  PUMP – Grundfos SQ-Flex series
                                                                                                                                                                      4         solar|pump                           1000                                                      Delivery head         Pump capacity*           Pump type

 Rated power Pmax                     155 Wp                            Power consumption max.                            900 W                                                                                                                                                15 m                  6.600 Liter/h            SQF-8A-3
                                                                                                                                                                          • MPP output: 936 Wp
 Rated voltage Umpp                   80 V                              Power I max.                                      7A                                                                                                                                                   30 m                  4.400 Liter/h            SQF-5A-6
                                                                                                                                                                          • 1 mast Type B
 Rated current Impp                   1,95 A                            Voltage U min. – U max.                           30 – 300 V / DC                                 • 2 module mount                                                                                     50 m                  2.750 Liter/h            SQF-2.5-2

 Open-circuit voltage Uoc             108,0 V                                                                                                                             • 6 modules                                                                                          75 m                  1.050 Liter/h            SQF-1.2-2
                                                                                                                                                                          • 2 strings
 Short-circuit current Isc            2,20 A                                                                                                                                                                                                                                   100 m                 970 Liter/h              SQF-1.2-2




     Hotline +49 (0) 33 34.59 44 40                                      Subject to change without notice. Images and descriptions do not claim to be exhaustive.   Subject to change without notice. Images and descriptions do not claim to be exhaustive.                                                  mp-tec Product Overview
Dimensions




                                                        30°
                                                                                                                                                        30°
                  3.615 mm
                             3.300 mm
                                           3.000 mm




                                                                   2.600 mm




                                                                                                                                            3.000 mm
                                                                                                                   3.865 mm

                                                                                                                                 3.300 mm




                                                                                                                                                                         2.350 mm
   solar|pump                                         300                          Mast type A              solar|pump                                 450               Mast type A




                                                         30°
                                                                                                                                                         30°
                  3.350 mm

                                3.300 mm




                                                                        2.660 mm




                                                                                                                   3.900 mm

                                                                                                                                 3.300 mm




                                                                                                                                                                                    2.390 mm




   solar|pump                                         600                          Mast type B              solar|pump                                 1000              Mast type B




                                                                                             up to                 *          Guarantee: up to a 15-years on the mounting system

easy to handle                                                                              15 years
                                                              virtually
                                                                                                             *                and 3-years on the pump
                                                      maintenance-free
                                                                                             product guarantee




 Hotline +49 (0) 33 34.59 44 40                                                                          Subject to change without notice. Images and descriptions do not claim to be exhaustive.

More Related Content

Similar to Product overview solar_pump

Cable size available guidelines network design
Cable size available guidelines network designCable size available guidelines network design
Cable size available guidelines network design
Manikandan Mani
 
improved reactive power capability of grid connected doubly fed induction gen...
improved reactive power capability of grid connected doubly fed induction gen...improved reactive power capability of grid connected doubly fed induction gen...
improved reactive power capability of grid connected doubly fed induction gen...
vinay kumar mali
 

Similar to Product overview solar_pump (20)

fdocuments.in_presentation-on-substation-220-kv.pptx
fdocuments.in_presentation-on-substation-220-kv.pptxfdocuments.in_presentation-on-substation-220-kv.pptx
fdocuments.in_presentation-on-substation-220-kv.pptx
 
Classification of Turbines
Classification of TurbinesClassification of Turbines
Classification of Turbines
 
Cable size available guidelines network design
Cable size available guidelines network designCable size available guidelines network design
Cable size available guidelines network design
 
Ashwani
AshwaniAshwani
Ashwani
 
Thermal power plant
Thermal power plantThermal power plant
Thermal power plant
 
Kaplan Turbine Details
Kaplan Turbine DetailsKaplan Turbine Details
Kaplan Turbine Details
 
5 power house
5 power house5 power house
5 power house
 
Energy management
Energy managementEnergy management
Energy management
 
improved reactive power capability of grid connected doubly fed induction gen...
improved reactive power capability of grid connected doubly fed induction gen...improved reactive power capability of grid connected doubly fed induction gen...
improved reactive power capability of grid connected doubly fed induction gen...
 
Power former
Power formerPower former
Power former
 
High-Brightness 9XX-nm Pumps with Wavelength Stabilization
High-Brightness 9XX-nm Pumps with Wavelength StabilizationHigh-Brightness 9XX-nm Pumps with Wavelength Stabilization
High-Brightness 9XX-nm Pumps with Wavelength Stabilization
 
FEEDER AND BUS BAR PROTECTION
FEEDER AND BUS BAR PROTECTIONFEEDER AND BUS BAR PROTECTION
FEEDER AND BUS BAR PROTECTION
 
Industrial training 220 KV moradabad
Industrial training 220 KV moradabadIndustrial training 220 KV moradabad
Industrial training 220 KV moradabad
 
training at uppcl khurram nagar 132/33 kv
training at uppcl khurram nagar 132/33 kvtraining at uppcl khurram nagar 132/33 kv
training at uppcl khurram nagar 132/33 kv
 
Coal Handling Plant
Coal Handling PlantCoal Handling Plant
Coal Handling Plant
 
200118 chapter 8 hydromechanical
200118 chapter 8 hydromechanical200118 chapter 8 hydromechanical
200118 chapter 8 hydromechanical
 
Hydel lecture-2
Hydel lecture-2Hydel lecture-2
Hydel lecture-2
 
SUMMER TRAINING @CHIBRO BY AAKASH
SUMMER TRAINING @CHIBRO BY AAKASH SUMMER TRAINING @CHIBRO BY AAKASH
SUMMER TRAINING @CHIBRO BY AAKASH
 
Magellan Power - High Reliability Australian Technology Innovative, Customise...
Magellan Power - High Reliability Australian Technology Innovative, Customise...Magellan Power - High Reliability Australian Technology Innovative, Customise...
Magellan Power - High Reliability Australian Technology Innovative, Customise...
 
Hydraulic Turbines – II: Governing of turbines – Surge tanks – Unit and speci...
Hydraulic Turbines – II: Governing of turbines – Surge tanks – Unit and speci...Hydraulic Turbines – II: Governing of turbines – Surge tanks – Unit and speci...
Hydraulic Turbines – II: Governing of turbines – Surge tanks – Unit and speci...
 

Product overview solar_pump

  • 1. Product Overview Solar subsurface pump system solarpump Solar Energy Solar Heat Mounting System Solar subsurface pump system solarpump 300, 450, 600 and 1000 english
  • 2. SOLAR SUBSURFACE PUMP SYSTEM solar|pump The system comprises four performance classes. * PV module under STC: AM 1.5; E= 1000 W/m² How it works: Example 1 Example 2 The solar subsurface pump system is used to deliver ground water independently and off-line. With its modular construction, You desire a pump system with a delivery volume You desire a pump system with a delivery capacity of at least - If the delivery head is not listed in of at least 3,000 litres per hour and a delivery 800 litres per hour and a delivery head of 80 metres. the individual components can be adapted to meet all requirements and application areas. the tables, round it up to the next head of 15 metres. higher available value. >> The delivery head “80 m” is not listed in any of the tables. - Determining values not listed in >> Starting with the smallest solar pump, look for Therefore always round up to the next higher available delivery Properties the table by interpolation or the value “15 m” in the tables and check the asso- head, in this case “100 m”. Starting with the smallest solar pump, extrapolation is not permitted. ciated delivery flow rate: The value of “3,000 litres look for the value “100 m” in the tables and check the associated - If the delivery head is lower with per hour” is first met by the solarpump 500, and delivery flow rate: solarpump 500 equates to 520 litres per hour, • Module surface area: 2,5 – 7,5 m² the same pump, this does not in this case, with 4,500 litres per hour, exceeded. solarpump 1000 970 litres per hour. • High stability (calculated according to DIN 1055/ EC 1) 1055 result in a higher delivery volume. - Only the same delivery volume The two search values of 3,000 litres per hour The two search values of 800 litres per hour and a delivery head • Continuously adjustable irradiation angle and azimuth may be planned. and a delivery head of 15 metres are met by the of 80 metres are met by configuration solarpump 1000 SQF-1.2-2 • Weight optimisation and prevention of rust formation through use of aluminium / steel configuration solarpump SQF-5A-6. • PV module installation with proven aluminium profiles from the in-house Quick-Line assembly system • Cable conduits and control assembly in mast, as required with protection against unauthorised access • Space-saving installation (modules can be sited above the well) 1 solar|pump 300 Delivery head Pump capacity* Pump type • Pump with run-dry protection, overvoltage and undervoltage protection as well as overload protection, 15 m 1.140 Liter/h SQF-1.2-2 overtemperature protection, maximum power point tracking, wide input voltage range • MPP output: 312 Wp 30 m 540 Liter/h SQF-0.6-2 • Simple system installation with factory pre-assembly • 1 mast Type A • Easy installation and maintenance of pump • 1 module mount 50 m 530 Liter/h SQF-0.6-2 • Installation on concrete foundations • 2 modules 75 m 500 Liter/h SQF-0.6-2 • Optional: upgrade with energy storage system • 2 strings Structure 2 solar|pump 450 Delivery head Pump capacity* Pump type The system comprises the following components: 15 m 4.500 Liter/h SQF-5A-6 b • MPP output: 468 Wp 30 m 2.300 Liter/h SQF-2.5-2 a Mast: Mast: two design types – mast A for one module mount • 1 mast Type A and mast B for two module mounts • 1 module mount 50 m 1.090 Liter/h SQF-1.2-2 • 3 modules 75 m 1.050 Liter/h SQF-1.2-2 b Module mount with modules: two design types modules: • 3 strings f 100 m 520 Liter/h SQF-0.6-2 for 2 or 3 photovoltaic modules a c c Pump: Pump: Grundfos SQ-Flex series submersible pump complete with d polyethylene pipe DN 30 (PE-HD drinking water, e 3 solar|pump 600 Delivery head Pump capacity* Pump type outside diameter: 32 mm, wall thickness: 2.4 mm), 15 m 5.600 Liter/h SQF-5A-6 e submarine cable, stainless steel support cable (cut to length), • MPP output: 624 Wp 30 m 3.000 Liter/h SQF-3A-10 screw connections, electrical connecting terminals, shrink • 1 mast Type B sleeve set d • 2 module mount 50 m 2.100 Liter/h SQF-2.5-2 f Disconnector unit (mp-tec) incl. fuse • 4 modules 100 m 970 Liter/h SQF-1.2-2 Optional: at extra charge, delivery with Grundfos CU200 • 2 strings pump control unit incl. float switch PV MODULE – Thin film module (example) PUMP – Grundfos SQ-Flex series 4 solar|pump 1000 Delivery head Pump capacity* Pump type Rated power Pmax 155 Wp Power consumption max. 900 W 15 m 6.600 Liter/h SQF-8A-3 • MPP output: 936 Wp Rated voltage Umpp 80 V Power I max. 7A 30 m 4.400 Liter/h SQF-5A-6 • 1 mast Type B Rated current Impp 1,95 A Voltage U min. – U max. 30 – 300 V / DC • 2 module mount 50 m 2.750 Liter/h SQF-2.5-2 Open-circuit voltage Uoc 108,0 V • 6 modules 75 m 1.050 Liter/h SQF-1.2-2 • 2 strings Short-circuit current Isc 2,20 A 100 m 970 Liter/h SQF-1.2-2 Hotline +49 (0) 33 34.59 44 40 Subject to change without notice. Images and descriptions do not claim to be exhaustive. Subject to change without notice. Images and descriptions do not claim to be exhaustive. mp-tec Product Overview
  • 3. Dimensions 30° 30° 3.615 mm 3.300 mm 3.000 mm 2.600 mm 3.000 mm 3.865 mm 3.300 mm 2.350 mm solar|pump 300 Mast type A solar|pump 450 Mast type A 30° 30° 3.350 mm 3.300 mm 2.660 mm 3.900 mm 3.300 mm 2.390 mm solar|pump 600 Mast type B solar|pump 1000 Mast type B up to * Guarantee: up to a 15-years on the mounting system easy to handle 15 years virtually * and 3-years on the pump maintenance-free product guarantee Hotline +49 (0) 33 34.59 44 40 Subject to change without notice. Images and descriptions do not claim to be exhaustive.