SlideShare a Scribd company logo
1 of 65
Download to read offline
By
Dr.K.Hussain
Associate Professor & Head
Dept. of EE, SITCOE
Time Domain Analysis
Introduction
• In time-domain analysis the response of a dynamic system to
an input is expressed as a function of time.
• It is possible to compute the time response of a system if the
nature of input and the mathematical model of the system
are known.
• Usually, the input signals to control systems are not known
fully ahead of time.
• It is therefore difficult to express the actual input signals
mathematically by simple equation
Standard Test Signals
• The characteristics of actual input signals are a sudden shock,
a sudden change, a constant velocity, and constant
acceleration.
• The dynamic behavior of a system is therefore judged and
compared under application of standard test signals – an
impulse, a step, a constant velocity, and constant acceleration.
• The other standard signal of great importance is a sinusoidal
signal.
Standard Test Signals
• Impulse signal
– The impulse signal imitate the
sudden shock characteristic of
actual input signal.
– If A=1, the impulse signal is
called unit impulse signal.
0 t
δ(t)
A






00
0
t
tA
t)(
Standard Test Signals
• Step signal
– The step signal imitate
the sudden change
characteristic of actual
input signal.
– If A=1, the step signal is
called unit step signal






00
0
t
tA
tu )( 0 t
u(t)
A
Standard Test Signals
• Ramp signal
– The ramp signal imitate
the constant velocity
characteristic of actual
input signal.
– If A=1, the ramp signal
is called unit ramp
signal






00
0
t
tAt
tr )(
0 t
r(t)
Standard Test Signals
• Parabolic signal
– The parabolic signal
imitate the constant
acceleration characteristic
of actual input signal.
– If A=1, the parabolic
signal is called unit
parabolic signal.








00
0
2
2
t
t
At
tp )(
0 t
p(t)
parabolic signal with slope A
p(t)
Unit parabolic signal
p(t)
Relation between standard Test Signals
• Impulse
• Step
• Ramp
• Parabolic






00
0
t
tA
t)(






00
0
t
tA
tu )(






00
0
t
tAt
tr )(








00
0
2
2
t
t
At
tp )(


 dt
d
dt
d
dt
d
Laplace Transform of Test Signals
• Impulse
• Step






00
0
t
tA
t)(
AstL  )()}({ 






00
0
t
tA
tu )(
S
A
sUtuL  )()}({
Laplace Transform of Test Signals
• Ramp
• Parabolic
2
s
A
sRtrL  )()}({
3
)()}({
S
A
sPtpL 






00
0
t
tAt
tr )(








00
0
2
2
t
t
At
tp )(
Time Response of Control Systems
System
• The time response of any system has two components
• Transient response
• Steady-state response.
• Time response of a dynamic system response to an input
expressed as a function of time.
Time Response of Control Systems
• When the response of the system is changed from equilibrium it
takes some time to settle down. This is called transient response.
0 2 4 6 8 10 12 14 16 18 20
0
1
2
3
4
5
6
x 10
-3
Step Response
Time (sec)
Amplitude
Response
Step Input
Transient Response
SteadyStateResponse
• The response of the
system after the transient
response is called steady
state response.
Time Response of Control Systems
• Transient response depend upon the system poles only and not
on the type of input.
• It is therefore sufficient to analyze the transient response using a
step input.
• The steady-state response depends on system dynamics and the
input quantity.
• It is then examined using different test signals by final value
theorem.
First order system
• The first order system has only one pole.
• Where K is the D.C gain and T is the time constant
of the system.
• Time constant is a measure of how quickly a 1st
order system responds to a unit step input.
• D.C Gain of the system is ratio between the input
signal and the steady state value of output.
1

Ts
K
sR
sC
)(
)(
Example 1
• The first order system given below.
13
10


s
sG )(
5
3


s
sG )(
151
53


s/
/
• D.C gain is 10 and time constant is 3 seconds.
• For the following system
• D.C Gain of the system is 3/5 and time constant is 1/5
seconds.
Impulse Response of 1st Order System
• Consider the following 1st order system
1Ts
K
)(sC)(sR
0
t
δ(t)
1
1 )()( ssR 
1

Ts
K
sC )(
Impulse Response of 1st Order System
• Re-arrange following equation as
1

Ts
K
sC )(
Ts
TK
sC
/
/
)(
1

Tt
e
T
K
tc /
)( 

• In order to compute the response of the system in time domain
we need to compute inverse Laplace transform of the above
equation.
at
Ce
as
C
L 







1
Step Response of 1st Order System
• Consider the following 1st order system
1Ts
K
)(sC)(sR
s
sUsR
1
 )()(
 1

Tss
K
sC )(
1

Ts
KT
s
K
sC )(
• In order to find out the inverse Laplace of the above equation, we
need to break it into partial fraction expansion
Step Response of 1st Order System
• Taking Inverse Laplace of above equation








1
1
Ts
T
s
KsC )(
 Tt
etuKtc /
)()( 

• Where u(t)=1
 Tt
eKtc /
)( 
 1
  KeKtc 63201 1
.)(  
• When t=T (time constant)
Relation Between Step and impulse
response
• The step response of the first order system is
• Differentiating c(t) with respect to t yields
  TtTt
KeKeKtc //
)( 
 1
 Tt
KeK
dt
d
dt
tdc /)( 

Tt
e
T
K
dt
tdc /)( 

Example 2
• If initial conditions are not known then partial fraction
expansion is a better choice
12
6


SsR
sC
)(
)(
 12
6


Ss
sC )(
  1212
6


 s
B
s
A
Ss
s
sRsR
1
)(,)( inputstepaissince
  50
66
12
6
.

 ssSs
t
etc 50
66 .
)( 

Ramp Response of 1st Order System
• Consider the following 1st order system
1Ts
K
)(sC)(sR
2
1
s
sR )(
 12


Tss
K
sC )(
• The ramp response is given as
 Tt
TeTtKtc /
)( 

Parabolic Response of 1st Order System
• Consider the following 1st order system
1Ts
K
)(sC)(sR
3
1
s
sR )(
 13


Tss
K
sC )(Therefore,
Second Order System
• We have already discussed the affect of location of poles and zeros on
the transient response of 1st order systems.
• Compared to the simplicity of a first-order system, a second-order system
exhibits a wide range of responses that must be analyzed and described.
• Varying a first-order system's parameter (T, K) simply changes the speed
and offset of the response
• Whereas, changes in the parameters of a second-order system can
change the form of the response.
• A second-order system can display characteristics much like a first-order
system or, depending on component values, display damped or pure
oscillations for its transient response. 24
Second Order System
• A general second-order system is characterized by the
following transfer function.
22
2
2 nn
n
sssR
sC




)(
)(
25
un-damped natural frequency of the second order system,
which is the frequency of oscillation of the system without
damping.
n
damping ratio of the second order system, which is a measure
of the degree of resistance to change in the system output.

Example 3
42
4
2


sssR
sC
)(
)(
• Determine the un-damped natural frequency and damping ratio
of the following second order system.
42
n
22
2
2 nn
n
sssR
sC




)(
)(
Sol: Compare the numerator and denominator of the given transfer
function with the general 2nd order transfer function.
2 n ssn 22  
422 222
 ssss nn 
50.
1 n
26
22
2
2 nn
n
sssR
sC




)(
)(
• Two poles of the system are
1
1
2
2




nn
nn
27
Second Order System
Second Order System Cont..
• According the value of , a second-order system can be set into
one of the four categories:
1
1
2
2




nn
nn

1. Overdamped - when the system has two real distinct poles ( >1).
-a-b-c
δ
jω
28
1
1
2
2




nn
nn
2. Underdamped - when the system has two complex conjugate poles (0 < <1)
-a-b-c
δ
jω
29
1
1
2
2




nn
nn
3. Undamped - when the system has two imaginary poles ( = 0).
-a-b-c
δ
jω
30
1
1
2
2




nn
nn
4. Critically damped - when the system has two real but equal poles ( = 1).
-a-b-c
δ
jω
31
Underdamped System
32
For 0< <1 and ωn > 0, the 2nd order system’s response due to a
unit step input is as follows.
Important timing characteristics: delay time, rise time, peak
time, maximum overshoot, and settling time.

Delay Time
33
• The delay (td) time is the time required for the response to
reach half the final value the very first time.
Rise Time
• The rise time is the time required for the response to rise from 10%
to 90%, 5% to 95%, or 0% to 100% of its final value.
• For underdamped second order systems, the 0% to 100% rise time is
normally used. For overdamped systems, the 10% to 90% rise time is
commonly used.
Peak Time
35
• The peak time is the time required for the response to reach
the first peak of the overshoot.
3535
Maximum Overshoot
36
The maximum overshoot is the maximum peak value of the
response curve measured from unity. If the final steady-state
value of the response differs from unity, then it is common to
use the maximum percent overshoot. It is defined by
The amount of the maximum (percent) overshoot directly
indicates the relative stability of the system.
Settling Time
37
• The settling time is the time required for the response curve
to reach and stay within a range about the final value of size
specified by absolute percentage of the final value (usually 2%
or 5%).
Step Response of underdamped System
222222
2
21
nnnn
n
ss
s
s
sC




)(
• The partial fraction expansion of above equation is given as
22
2
21
nn
n
ss
s
s
sC




)(
 2
2 ns 
 22
1  n
   222
1
21





nn
n
s
s
s
sC )(
22
2
2 nn
n
sssR
sC




)(
)(
 22
2
2 nn
n
sss
sC



)(
Step Response
38
Step Response of underdamped System
• Above equation can be written as
   222
1
21





nn
n
s
s
s
sC )(
  22
21
dn
n
s
s
s
sC




)(
2
1   nd• Where , is the frequency of transient oscillations
and is called damped natural frequency.
• The inverse Laplace transform of above equation can be obtained
easily if C(s) is written in the following form:
    2222
1
dn
n
dn
n
ss
s
s
sC








)(
39
Step Response of underdamped System
    2222
1
dn
n
dn
n
ss
s
s
sC








)(
    22
2
2
22
1
11
dn
n
dn
n
ss
s
s
sC












)(
    22222
1
1
dn
d
dn
n
ss
s
s
sC










)(
tetetc d
t
d
t nn



 
sincos)( 


2
1
1
40
Step Response of underdamped System
tetetc d
t
d
t nn



 
sincos)( 


2
1
1









 
ttetc dd
tn




sincos)(
2
1
1
41
2
2
1
( ) 1 sin( )
1
1
tan
nt
d
e
c t t
where

 






  



Steady State Error
• If the output of a control system at steady state
does not exactly match with the input, the system
is said to have steady state error
• Any physical control system inherently suffers
steady-state error in response to certain types of
inputs.
• A system may have no steady-state error to a step
input, but the same system may exhibit nonzero
steady-state error to a ramp input.
Classification of Control Systems
• Control systems may be classified according to
their ability to follow step inputs, ramp inputs,
parabolic inputs, and so on.
• The magnitudes of the steady-state errors due
to these individual inputs are indicative of the
goodness of the system.
Classification of Control Systems
• Consider the unity-feedback control system
with the following open-loop transfer function
• It involves the term sN in the denominator,
representing N poles at the origin.
• A system is called type 0, type 1, type 2, ... , if
N=0, N=1, N=2, ... , respectively.
Classification of Control Systems
• As the type number is increased, accuracy is
improved.
• However, increasing the type number
aggravates the stability problem.
• A compromise between steady-state accuracy
and relative stability is always necessary.
Steady State Error of Unity Feedback Systems
• Consider the system shown in following figure.
• The closed-loop transfer function is
Steady State Error of Unity Feedback Systems
• The transfer function between the error signal E(s) and the
input signal R(s) is
)()(
)(
sGsR
sE


1
1
• The final-value theorem provides a convenient way to find
the steady-state performance of a stable system.
• Since E(s) is
• The steady state error is
Static Error Constants
• The static error constants are figures of merit of
control systems. The higher the constants, the
smaller the steady-state error.
• In a given system, the output may be the position,
velocity, pressure, temperature, or the like.
• Therefore, in what follows, we shall call the output
“position,” the rate of change of the output
“velocity,” and so on.
• This means that in a temperature control system
“position” represents the output temperature,
“velocity” represents the rate of change of the
output temperature, and so on.
Static Position Error Constant (Kp)
• The steady-state error of the system for a unit-step input is
• The static position error constant Kp is defined by
• Thus, the steady-state error in terms of the static position
error constant Kp is given by
Static Position Error Constant (Kp)
• For a Type 0 system
• For Type 1 or higher order systems
• For a unit step input the steady state error ess is
• The steady-state error of the system for a unit-ramp input is
• The static velocity error constant Kv is defined by
• Thus, the steady-state error in terms of the static velocity
error constant Kv is given by
Static Velocity Error Constant (Kv)
Static Velocity Error Constant (Kv)
• For a Type 0 system
• For Type 1 systems
• For type 2 or higher order systems
Static Velocity Error Constant (Kv)
• For a ramp input the steady state error ess is
• The steady-state error of the system for parabolic input is
• The static acceleration error constant Ka is defined by
• Thus, the steady-state error in terms of the static acceleration
error constant Ka is given by
Static Acceleration Error Constant (Ka)
Static Acceleration Error Constant (Ka)
• For a Type 0 system
• For Type 1 systems
• For type 2 systems
• For type 3 or higher order systems
Static Acceleration Error Constant (Ka)
• For a parabolic input the steady state error ess is
Summary of Steady State Errors
Example 4
• For the system shown in figure below evaluate the static
error constants and find the expected steady state errors
for the standard step, ramp and parabolic inputs.
C(S)R(S) -
))((
))((
128
52100
2


sss
ss
Example 4
))((
))((
)(
128
52100
2



sss
ss
sG
)(lim sGK
s
p
0










 ))((
))((
lim
128
52100
2
0 sss
ss
K
s
p
pK
)(lim ssGK
s
v
0










 ))((
))((
lim
128
52100
2
0 sss
sss
K
s
v
vK
)(lim sGsK
s
a
2
0












 ))((
))((
lim
128
52100
2
2
0 sss
sss
K
s
a
410
12080
5020100
.
))((
))((








aK
Example 4
pK vK 410.aK
0
0
090.
Ex 5: The open loop transfer function of a servo system
with unity feedback is given by
Determine the damping ratio, undamped natural
frequency of oscillation. What is the percentage
overshoot of the response to a unit step input.
SOLUTION: Given that
Characteristic equation
10
(s  2)(s  5)
G(s) 
10
H(s) 1
(s  2)(s 5)
G(s) 
1 G(s)H (s)  0
10
 01
s2
 7s  20  0
(s  2)(s 5)
Compare with s2
 2 s 2
 0
n n
We get
*100 1.92%
16
1(0.7826)2

*0.7826
12

2* *4.472 7
  0.7826
 2
20
 e
20  4.472rad /sec
M p e
n 
n
2n  7  n 4.472rad /sec
  0.7826
M p 1.92%
H (s)  Ks
The damping factor of the system is 0.8. Determine the
overshoot of the system and value of ‘K’.
SOLUTION: We know that
12
G(s) 
s2
 4s 16
s2
 (4 16K)s 16  0
s2
 (4 16K)s 16R(s)
C(s)

1 G(s)H(s)
16
G(s)
R(s)
C(s)

is the characteristic eqn.
Ex 6: A feedback system is described by the following transfer
function
nn
2
n
2
Compare with
2
16
s  2 s   0
n  4rad /sec.
2n  4 16K
2*0.8*4  4 16K  K  0 . 1 5
*1001(0.8)2

M p 1.5%
*100 eM p  e
0.8
12

Ex 7: The open loop transfer function of unity feedback
system is given by
SOLUTION:
50
(1 0.1s)(s10)
G(s) 
Determine the static error coefficients Kp , Kv andKa
50
50
50
 0
 0
 5 lim
(1 0.1s)(s10)
(1 0.1s)(s10)
K  lims.G(s)H (s)
K  limG(s)H(s)
 lim s2
s0
2
Ka  s G(s)H (s)
 lims.
s0
s0
v
s0 (1 0.1s)(s 10)
s0
p

More Related Content

What's hot

What's hot (20)

Time domain analysis
Time domain analysisTime domain analysis
Time domain analysis
 
Time response second order
Time response second orderTime response second order
Time response second order
 
ppt on Time Domain and Frequency Domain Analysis
ppt on Time Domain and Frequency Domain Analysisppt on Time Domain and Frequency Domain Analysis
ppt on Time Domain and Frequency Domain Analysis
 
Modern Control - Lec07 - State Space Modeling of LTI Systems
Modern Control - Lec07 - State Space Modeling of LTI SystemsModern Control - Lec07 - State Space Modeling of LTI Systems
Modern Control - Lec07 - State Space Modeling of LTI Systems
 
state space representation,State Space Model Controllability and Observabilit...
state space representation,State Space Model Controllability and Observabilit...state space representation,State Space Model Controllability and Observabilit...
state space representation,State Space Model Controllability and Observabilit...
 
Modern Control - Lec 03 - Feedback Control Systems Performance and Characteri...
Modern Control - Lec 03 - Feedback Control Systems Performance and Characteri...Modern Control - Lec 03 - Feedback Control Systems Performance and Characteri...
Modern Control - Lec 03 - Feedback Control Systems Performance and Characteri...
 
Control systems
Control systems Control systems
Control systems
 
Time response analysis
Time response analysisTime response analysis
Time response analysis
 
Time response first order
Time response first orderTime response first order
Time response first order
 
Control system lectures
Control system lectures Control system lectures
Control system lectures
 
STate Space Analysis
STate Space AnalysisSTate Space Analysis
STate Space Analysis
 
Modern Control - Lec 05 - Analysis and Design of Control Systems using Freque...
Modern Control - Lec 05 - Analysis and Design of Control Systems using Freque...Modern Control - Lec 05 - Analysis and Design of Control Systems using Freque...
Modern Control - Lec 05 - Analysis and Design of Control Systems using Freque...
 
Frequency Response Analysis
Frequency Response AnalysisFrequency Response Analysis
Frequency Response Analysis
 
BEC- 26 control systems_unit-II
BEC- 26 control systems_unit-IIBEC- 26 control systems_unit-II
BEC- 26 control systems_unit-II
 
Time response and analysis kaushal shah
Time response and analysis kaushal shahTime response and analysis kaushal shah
Time response and analysis kaushal shah
 
Ch5 transient and steady state response analyses(control)
Ch5  transient and steady state response analyses(control)Ch5  transient and steady state response analyses(control)
Ch5 transient and steady state response analyses(control)
 
digital control Chapter1 slide
digital control Chapter1 slidedigital control Chapter1 slide
digital control Chapter1 slide
 
PID Control System
PID Control System PID Control System
PID Control System
 
Week 17 digital control sytem
Week 17 digital control sytemWeek 17 digital control sytem
Week 17 digital control sytem
 
Basic elements in control systems
Basic elements in control systemsBasic elements in control systems
Basic elements in control systems
 

Similar to Time domain analysis

Lecture 13 14-time_domain_analysis_of_1st_order_systems
Lecture 13 14-time_domain_analysis_of_1st_order_systemsLecture 13 14-time_domain_analysis_of_1st_order_systems
Lecture 13 14-time_domain_analysis_of_1st_order_systems
Saifullah Memon
 
lecture_1_introduction__review_of_classical_control.pptx
lecture_1_introduction__review_of_classical_control.pptxlecture_1_introduction__review_of_classical_control.pptx
lecture_1_introduction__review_of_classical_control.pptx
jpradha86
 

Similar to Time domain analysis (20)

time domain analysis.pptx
time domain analysis.pptxtime domain analysis.pptx
time domain analysis.pptx
 
LCE-UNIT 1 PPT.pdf
LCE-UNIT 1 PPT.pdfLCE-UNIT 1 PPT.pdf
LCE-UNIT 1 PPT.pdf
 
lecture1 (5).ppt
lecture1 (5).pptlecture1 (5).ppt
lecture1 (5).ppt
 
Transient and Steady State Response - Control Systems Engineering
Transient and Steady State Response - Control Systems EngineeringTransient and Steady State Response - Control Systems Engineering
Transient and Steady State Response - Control Systems Engineering
 
KEC-602 Control System Unit-3 gandgfdghhg
KEC-602 Control System Unit-3 gandgfdghhgKEC-602 Control System Unit-3 gandgfdghhg
KEC-602 Control System Unit-3 gandgfdghhg
 
Order of instruments.ppt
Order of instruments.pptOrder of instruments.ppt
Order of instruments.ppt
 
Me314 week 06-07-Time Response
Me314 week 06-07-Time ResponseMe314 week 06-07-Time Response
Me314 week 06-07-Time Response
 
Time response in systems
Time response in systemsTime response in systems
Time response in systems
 
Chapter 3-Dynamic Behavior of First and Second Order Processes-1.pptx
Chapter 3-Dynamic Behavior of First and Second Order Processes-1.pptxChapter 3-Dynamic Behavior of First and Second Order Processes-1.pptx
Chapter 3-Dynamic Behavior of First and Second Order Processes-1.pptx
 
Lecture 13 14-time_domain_analysis_of_1st_order_systems
Lecture 13 14-time_domain_analysis_of_1st_order_systemsLecture 13 14-time_domain_analysis_of_1st_order_systems
Lecture 13 14-time_domain_analysis_of_1st_order_systems
 
Instrumentation Lab. Experiment #2 Report: System Response Characteristics
Instrumentation Lab. Experiment #2 Report: System Response CharacteristicsInstrumentation Lab. Experiment #2 Report: System Response Characteristics
Instrumentation Lab. Experiment #2 Report: System Response Characteristics
 
Lecture 14 15-time_domain_analysis_of_2nd_order_systems
Lecture 14 15-time_domain_analysis_of_2nd_order_systemsLecture 14 15-time_domain_analysis_of_2nd_order_systems
Lecture 14 15-time_domain_analysis_of_2nd_order_systems
 
Lecture 13 14-time_domain_analysis_of_1st_order_systems
Lecture 13 14-time_domain_analysis_of_1st_order_systemsLecture 13 14-time_domain_analysis_of_1st_order_systems
Lecture 13 14-time_domain_analysis_of_1st_order_systems
 
15269202.ppt
15269202.ppt15269202.ppt
15269202.ppt
 
control systems - time specification domains
control systems - time specification domainscontrol systems - time specification domains
control systems - time specification domains
 
K10655(hariom) control theory
K10655(hariom) control theoryK10655(hariom) control theory
K10655(hariom) control theory
 
lecture_1_introduction__review_of_classical_control.pptx
lecture_1_introduction__review_of_classical_control.pptxlecture_1_introduction__review_of_classical_control.pptx
lecture_1_introduction__review_of_classical_control.pptx
 
5 2020 04_06!09_40_10_pm
5 2020 04_06!09_40_10_pm5 2020 04_06!09_40_10_pm
5 2020 04_06!09_40_10_pm
 
03 dynamic.system.
03 dynamic.system.03 dynamic.system.
03 dynamic.system.
 
Time response of discrete systems 4th lecture
Time response of discrete systems 4th lectureTime response of discrete systems 4th lecture
Time response of discrete systems 4th lecture
 

More from Hussain K

More from Hussain K (17)

NA-Duality& Dual Networks.pptx
NA-Duality& Dual Networks.pptxNA-Duality& Dual Networks.pptx
NA-Duality& Dual Networks.pptx
 
Tellegen’s-Substitution-Reciprocity-Theorem.ppt
Tellegen’s-Substitution-Reciprocity-Theorem.pptTellegen’s-Substitution-Reciprocity-Theorem.ppt
Tellegen’s-Substitution-Reciprocity-Theorem.ppt
 
NAS-Unit-5_Two Port Networks
NAS-Unit-5_Two Port NetworksNAS-Unit-5_Two Port Networks
NAS-Unit-5_Two Port Networks
 
NAS-Ch4-Application of Laplace Transform
NAS-Ch4-Application of Laplace TransformNAS-Ch4-Application of Laplace Transform
NAS-Ch4-Application of Laplace Transform
 
NAS-Ch3-Solutions of Equations
NAS-Ch3-Solutions of EquationsNAS-Ch3-Solutions of Equations
NAS-Ch3-Solutions of Equations
 
NAS-Ch2-Network Equations
NAS-Ch2-Network EquationsNAS-Ch2-Network Equations
NAS-Ch2-Network Equations
 
NAS-Ch2-Network-Theorems
NAS-Ch2-Network-TheoremsNAS-Ch2-Network-Theorems
NAS-Ch2-Network-Theorems
 
NAS-Ch1-Part1-Circuit Elements
NAS-Ch1-Part1-Circuit ElementsNAS-Ch1-Part1-Circuit Elements
NAS-Ch1-Part1-Circuit Elements
 
PID Controllers
PID Controllers PID Controllers
PID Controllers
 
Bode Plots
Bode Plots Bode Plots
Bode Plots
 
Nyquist Stability Criterion
Nyquist  Stability CriterionNyquist  Stability Criterion
Nyquist Stability Criterion
 
Polar Plot
Polar PlotPolar Plot
Polar Plot
 
Root Locus Plot
Root Locus Plot Root Locus Plot
Root Locus Plot
 
Stabiltiy & R-H Ccriterion
Stabiltiy & R-H CcriterionStabiltiy & R-H Ccriterion
Stabiltiy & R-H Ccriterion
 
Control systems formula book
Control systems formula bookControl systems formula book
Control systems formula book
 
Pid controllers
Pid controllersPid controllers
Pid controllers
 
Block diagrams and signal flow graphs
Block diagrams and signal flow graphsBlock diagrams and signal flow graphs
Block diagrams and signal flow graphs
 

Recently uploaded

Activity 01 - Artificial Culture (1).pdf
Activity 01 - Artificial Culture (1).pdfActivity 01 - Artificial Culture (1).pdf
Activity 01 - Artificial Culture (1).pdf
ciinovamais
 

Recently uploaded (20)

Unit-IV- Pharma. Marketing Channels.pptx
Unit-IV- Pharma. Marketing Channels.pptxUnit-IV- Pharma. Marketing Channels.pptx
Unit-IV- Pharma. Marketing Channels.pptx
 
Advanced Views - Calendar View in Odoo 17
Advanced Views - Calendar View in Odoo 17Advanced Views - Calendar View in Odoo 17
Advanced Views - Calendar View in Odoo 17
 
PROCESS RECORDING FORMAT.docx
PROCESS      RECORDING        FORMAT.docxPROCESS      RECORDING        FORMAT.docx
PROCESS RECORDING FORMAT.docx
 
Class 11th Physics NEET formula sheet pdf
Class 11th Physics NEET formula sheet pdfClass 11th Physics NEET formula sheet pdf
Class 11th Physics NEET formula sheet pdf
 
Energy Resources. ( B. Pharmacy, 1st Year, Sem-II) Natural Resources
Energy Resources. ( B. Pharmacy, 1st Year, Sem-II) Natural ResourcesEnergy Resources. ( B. Pharmacy, 1st Year, Sem-II) Natural Resources
Energy Resources. ( B. Pharmacy, 1st Year, Sem-II) Natural Resources
 
Food Chain and Food Web (Ecosystem) EVS, B. Pharmacy 1st Year, Sem-II
Food Chain and Food Web (Ecosystem) EVS, B. Pharmacy 1st Year, Sem-IIFood Chain and Food Web (Ecosystem) EVS, B. Pharmacy 1st Year, Sem-II
Food Chain and Food Web (Ecosystem) EVS, B. Pharmacy 1st Year, Sem-II
 
Explore beautiful and ugly buildings. Mathematics helps us create beautiful d...
Explore beautiful and ugly buildings. Mathematics helps us create beautiful d...Explore beautiful and ugly buildings. Mathematics helps us create beautiful d...
Explore beautiful and ugly buildings. Mathematics helps us create beautiful d...
 
Role Of Transgenic Animal In Target Validation-1.pptx
Role Of Transgenic Animal In Target Validation-1.pptxRole Of Transgenic Animal In Target Validation-1.pptx
Role Of Transgenic Animal In Target Validation-1.pptx
 
Holdier Curriculum Vitae (April 2024).pdf
Holdier Curriculum Vitae (April 2024).pdfHoldier Curriculum Vitae (April 2024).pdf
Holdier Curriculum Vitae (April 2024).pdf
 
Basic Civil Engineering first year Notes- Chapter 4 Building.pptx
Basic Civil Engineering first year Notes- Chapter 4 Building.pptxBasic Civil Engineering first year Notes- Chapter 4 Building.pptx
Basic Civil Engineering first year Notes- Chapter 4 Building.pptx
 
Python Notes for mca i year students osmania university.docx
Python Notes for mca i year students osmania university.docxPython Notes for mca i year students osmania university.docx
Python Notes for mca i year students osmania university.docx
 
ComPTIA Overview | Comptia Security+ Book SY0-701
ComPTIA Overview | Comptia Security+ Book SY0-701ComPTIA Overview | Comptia Security+ Book SY0-701
ComPTIA Overview | Comptia Security+ Book SY0-701
 
ICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptxICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptx
 
2024-NATIONAL-LEARNING-CAMP-AND-OTHER.pptx
2024-NATIONAL-LEARNING-CAMP-AND-OTHER.pptx2024-NATIONAL-LEARNING-CAMP-AND-OTHER.pptx
2024-NATIONAL-LEARNING-CAMP-AND-OTHER.pptx
 
Mehran University Newsletter Vol-X, Issue-I, 2024
Mehran University Newsletter Vol-X, Issue-I, 2024Mehran University Newsletter Vol-X, Issue-I, 2024
Mehran University Newsletter Vol-X, Issue-I, 2024
 
TỔNG ÔN TẬP THI VÀO LỚP 10 MÔN TIẾNG ANH NĂM HỌC 2023 - 2024 CÓ ĐÁP ÁN (NGỮ Â...
TỔNG ÔN TẬP THI VÀO LỚP 10 MÔN TIẾNG ANH NĂM HỌC 2023 - 2024 CÓ ĐÁP ÁN (NGỮ Â...TỔNG ÔN TẬP THI VÀO LỚP 10 MÔN TIẾNG ANH NĂM HỌC 2023 - 2024 CÓ ĐÁP ÁN (NGỮ Â...
TỔNG ÔN TẬP THI VÀO LỚP 10 MÔN TIẾNG ANH NĂM HỌC 2023 - 2024 CÓ ĐÁP ÁN (NGỮ Â...
 
Activity 01 - Artificial Culture (1).pdf
Activity 01 - Artificial Culture (1).pdfActivity 01 - Artificial Culture (1).pdf
Activity 01 - Artificial Culture (1).pdf
 
Nutritional Needs Presentation - HLTH 104
Nutritional Needs Presentation - HLTH 104Nutritional Needs Presentation - HLTH 104
Nutritional Needs Presentation - HLTH 104
 
On National Teacher Day, meet the 2024-25 Kenan Fellows
On National Teacher Day, meet the 2024-25 Kenan FellowsOn National Teacher Day, meet the 2024-25 Kenan Fellows
On National Teacher Day, meet the 2024-25 Kenan Fellows
 
Measures of Central Tendency: Mean, Median and Mode
Measures of Central Tendency: Mean, Median and ModeMeasures of Central Tendency: Mean, Median and Mode
Measures of Central Tendency: Mean, Median and Mode
 

Time domain analysis

  • 1. By Dr.K.Hussain Associate Professor & Head Dept. of EE, SITCOE Time Domain Analysis
  • 2. Introduction • In time-domain analysis the response of a dynamic system to an input is expressed as a function of time. • It is possible to compute the time response of a system if the nature of input and the mathematical model of the system are known. • Usually, the input signals to control systems are not known fully ahead of time. • It is therefore difficult to express the actual input signals mathematically by simple equation
  • 3. Standard Test Signals • The characteristics of actual input signals are a sudden shock, a sudden change, a constant velocity, and constant acceleration. • The dynamic behavior of a system is therefore judged and compared under application of standard test signals – an impulse, a step, a constant velocity, and constant acceleration. • The other standard signal of great importance is a sinusoidal signal.
  • 4. Standard Test Signals • Impulse signal – The impulse signal imitate the sudden shock characteristic of actual input signal. – If A=1, the impulse signal is called unit impulse signal. 0 t δ(t) A       00 0 t tA t)(
  • 5. Standard Test Signals • Step signal – The step signal imitate the sudden change characteristic of actual input signal. – If A=1, the step signal is called unit step signal       00 0 t tA tu )( 0 t u(t) A
  • 6. Standard Test Signals • Ramp signal – The ramp signal imitate the constant velocity characteristic of actual input signal. – If A=1, the ramp signal is called unit ramp signal       00 0 t tAt tr )( 0 t r(t)
  • 7. Standard Test Signals • Parabolic signal – The parabolic signal imitate the constant acceleration characteristic of actual input signal. – If A=1, the parabolic signal is called unit parabolic signal.         00 0 2 2 t t At tp )( 0 t p(t) parabolic signal with slope A p(t) Unit parabolic signal p(t)
  • 8. Relation between standard Test Signals • Impulse • Step • Ramp • Parabolic       00 0 t tA t)(       00 0 t tA tu )(       00 0 t tAt tr )(         00 0 2 2 t t At tp )(    dt d dt d dt d
  • 9. Laplace Transform of Test Signals • Impulse • Step       00 0 t tA t)( AstL  )()}({        00 0 t tA tu )( S A sUtuL  )()}({
  • 10. Laplace Transform of Test Signals • Ramp • Parabolic 2 s A sRtrL  )()}({ 3 )()}({ S A sPtpL        00 0 t tAt tr )(         00 0 2 2 t t At tp )(
  • 11. Time Response of Control Systems System • The time response of any system has two components • Transient response • Steady-state response. • Time response of a dynamic system response to an input expressed as a function of time.
  • 12. Time Response of Control Systems • When the response of the system is changed from equilibrium it takes some time to settle down. This is called transient response. 0 2 4 6 8 10 12 14 16 18 20 0 1 2 3 4 5 6 x 10 -3 Step Response Time (sec) Amplitude Response Step Input Transient Response SteadyStateResponse • The response of the system after the transient response is called steady state response.
  • 13. Time Response of Control Systems • Transient response depend upon the system poles only and not on the type of input. • It is therefore sufficient to analyze the transient response using a step input. • The steady-state response depends on system dynamics and the input quantity. • It is then examined using different test signals by final value theorem.
  • 14. First order system • The first order system has only one pole. • Where K is the D.C gain and T is the time constant of the system. • Time constant is a measure of how quickly a 1st order system responds to a unit step input. • D.C Gain of the system is ratio between the input signal and the steady state value of output. 1  Ts K sR sC )( )(
  • 15. Example 1 • The first order system given below. 13 10   s sG )( 5 3   s sG )( 151 53   s/ / • D.C gain is 10 and time constant is 3 seconds. • For the following system • D.C Gain of the system is 3/5 and time constant is 1/5 seconds.
  • 16. Impulse Response of 1st Order System • Consider the following 1st order system 1Ts K )(sC)(sR 0 t δ(t) 1 1 )()( ssR  1  Ts K sC )(
  • 17. Impulse Response of 1st Order System • Re-arrange following equation as 1  Ts K sC )( Ts TK sC / / )( 1  Tt e T K tc / )(   • In order to compute the response of the system in time domain we need to compute inverse Laplace transform of the above equation. at Ce as C L         1
  • 18. Step Response of 1st Order System • Consider the following 1st order system 1Ts K )(sC)(sR s sUsR 1  )()(  1  Tss K sC )( 1  Ts KT s K sC )( • In order to find out the inverse Laplace of the above equation, we need to break it into partial fraction expansion
  • 19. Step Response of 1st Order System • Taking Inverse Laplace of above equation         1 1 Ts T s KsC )(  Tt etuKtc / )()(   • Where u(t)=1  Tt eKtc / )(   1   KeKtc 63201 1 .)(   • When t=T (time constant)
  • 20. Relation Between Step and impulse response • The step response of the first order system is • Differentiating c(t) with respect to t yields   TtTt KeKeKtc // )(   1  Tt KeK dt d dt tdc /)(   Tt e T K dt tdc /)(  
  • 21. Example 2 • If initial conditions are not known then partial fraction expansion is a better choice 12 6   SsR sC )( )(  12 6   Ss sC )(   1212 6    s B s A Ss s sRsR 1 )(,)( inputstepaissince   50 66 12 6 .   ssSs t etc 50 66 . )(  
  • 22. Ramp Response of 1st Order System • Consider the following 1st order system 1Ts K )(sC)(sR 2 1 s sR )(  12   Tss K sC )( • The ramp response is given as  Tt TeTtKtc / )(  
  • 23. Parabolic Response of 1st Order System • Consider the following 1st order system 1Ts K )(sC)(sR 3 1 s sR )(  13   Tss K sC )(Therefore,
  • 24. Second Order System • We have already discussed the affect of location of poles and zeros on the transient response of 1st order systems. • Compared to the simplicity of a first-order system, a second-order system exhibits a wide range of responses that must be analyzed and described. • Varying a first-order system's parameter (T, K) simply changes the speed and offset of the response • Whereas, changes in the parameters of a second-order system can change the form of the response. • A second-order system can display characteristics much like a first-order system or, depending on component values, display damped or pure oscillations for its transient response. 24
  • 25. Second Order System • A general second-order system is characterized by the following transfer function. 22 2 2 nn n sssR sC     )( )( 25 un-damped natural frequency of the second order system, which is the frequency of oscillation of the system without damping. n damping ratio of the second order system, which is a measure of the degree of resistance to change in the system output. 
  • 26. Example 3 42 4 2   sssR sC )( )( • Determine the un-damped natural frequency and damping ratio of the following second order system. 42 n 22 2 2 nn n sssR sC     )( )( Sol: Compare the numerator and denominator of the given transfer function with the general 2nd order transfer function. 2 n ssn 22   422 222  ssss nn  50. 1 n 26
  • 27. 22 2 2 nn n sssR sC     )( )( • Two poles of the system are 1 1 2 2     nn nn 27 Second Order System
  • 28. Second Order System Cont.. • According the value of , a second-order system can be set into one of the four categories: 1 1 2 2     nn nn  1. Overdamped - when the system has two real distinct poles ( >1). -a-b-c δ jω 28
  • 29. 1 1 2 2     nn nn 2. Underdamped - when the system has two complex conjugate poles (0 < <1) -a-b-c δ jω 29
  • 30. 1 1 2 2     nn nn 3. Undamped - when the system has two imaginary poles ( = 0). -a-b-c δ jω 30
  • 31. 1 1 2 2     nn nn 4. Critically damped - when the system has two real but equal poles ( = 1). -a-b-c δ jω 31
  • 32. Underdamped System 32 For 0< <1 and ωn > 0, the 2nd order system’s response due to a unit step input is as follows. Important timing characteristics: delay time, rise time, peak time, maximum overshoot, and settling time. 
  • 33. Delay Time 33 • The delay (td) time is the time required for the response to reach half the final value the very first time.
  • 34. Rise Time • The rise time is the time required for the response to rise from 10% to 90%, 5% to 95%, or 0% to 100% of its final value. • For underdamped second order systems, the 0% to 100% rise time is normally used. For overdamped systems, the 10% to 90% rise time is commonly used.
  • 35. Peak Time 35 • The peak time is the time required for the response to reach the first peak of the overshoot. 3535
  • 36. Maximum Overshoot 36 The maximum overshoot is the maximum peak value of the response curve measured from unity. If the final steady-state value of the response differs from unity, then it is common to use the maximum percent overshoot. It is defined by The amount of the maximum (percent) overshoot directly indicates the relative stability of the system.
  • 37. Settling Time 37 • The settling time is the time required for the response curve to reach and stay within a range about the final value of size specified by absolute percentage of the final value (usually 2% or 5%).
  • 38. Step Response of underdamped System 222222 2 21 nnnn n ss s s sC     )( • The partial fraction expansion of above equation is given as 22 2 21 nn n ss s s sC     )(  2 2 ns   22 1  n    222 1 21      nn n s s s sC )( 22 2 2 nn n sssR sC     )( )(  22 2 2 nn n sss sC    )( Step Response 38
  • 39. Step Response of underdamped System • Above equation can be written as    222 1 21      nn n s s s sC )(   22 21 dn n s s s sC     )( 2 1   nd• Where , is the frequency of transient oscillations and is called damped natural frequency. • The inverse Laplace transform of above equation can be obtained easily if C(s) is written in the following form:     2222 1 dn n dn n ss s s sC         )( 39
  • 40. Step Response of underdamped System     2222 1 dn n dn n ss s s sC         )(     22 2 2 22 1 11 dn n dn n ss s s sC             )(     22222 1 1 dn d dn n ss s s sC           )( tetetc d t d t nn      sincos)(    2 1 1 40
  • 41. Step Response of underdamped System tetetc d t d t nn      sincos)(    2 1 1            ttetc dd tn     sincos)( 2 1 1 41 2 2 1 ( ) 1 sin( ) 1 1 tan nt d e c t t where               
  • 42. Steady State Error • If the output of a control system at steady state does not exactly match with the input, the system is said to have steady state error • Any physical control system inherently suffers steady-state error in response to certain types of inputs. • A system may have no steady-state error to a step input, but the same system may exhibit nonzero steady-state error to a ramp input.
  • 43. Classification of Control Systems • Control systems may be classified according to their ability to follow step inputs, ramp inputs, parabolic inputs, and so on. • The magnitudes of the steady-state errors due to these individual inputs are indicative of the goodness of the system.
  • 44. Classification of Control Systems • Consider the unity-feedback control system with the following open-loop transfer function • It involves the term sN in the denominator, representing N poles at the origin. • A system is called type 0, type 1, type 2, ... , if N=0, N=1, N=2, ... , respectively.
  • 45. Classification of Control Systems • As the type number is increased, accuracy is improved. • However, increasing the type number aggravates the stability problem. • A compromise between steady-state accuracy and relative stability is always necessary.
  • 46. Steady State Error of Unity Feedback Systems • Consider the system shown in following figure. • The closed-loop transfer function is
  • 47. Steady State Error of Unity Feedback Systems • The transfer function between the error signal E(s) and the input signal R(s) is )()( )( sGsR sE   1 1 • The final-value theorem provides a convenient way to find the steady-state performance of a stable system. • Since E(s) is • The steady state error is
  • 48. Static Error Constants • The static error constants are figures of merit of control systems. The higher the constants, the smaller the steady-state error. • In a given system, the output may be the position, velocity, pressure, temperature, or the like. • Therefore, in what follows, we shall call the output “position,” the rate of change of the output “velocity,” and so on. • This means that in a temperature control system “position” represents the output temperature, “velocity” represents the rate of change of the output temperature, and so on.
  • 49. Static Position Error Constant (Kp) • The steady-state error of the system for a unit-step input is • The static position error constant Kp is defined by • Thus, the steady-state error in terms of the static position error constant Kp is given by
  • 50. Static Position Error Constant (Kp) • For a Type 0 system • For Type 1 or higher order systems • For a unit step input the steady state error ess is
  • 51. • The steady-state error of the system for a unit-ramp input is • The static velocity error constant Kv is defined by • Thus, the steady-state error in terms of the static velocity error constant Kv is given by Static Velocity Error Constant (Kv)
  • 52. Static Velocity Error Constant (Kv) • For a Type 0 system • For Type 1 systems • For type 2 or higher order systems
  • 53. Static Velocity Error Constant (Kv) • For a ramp input the steady state error ess is
  • 54. • The steady-state error of the system for parabolic input is • The static acceleration error constant Ka is defined by • Thus, the steady-state error in terms of the static acceleration error constant Ka is given by Static Acceleration Error Constant (Ka)
  • 55. Static Acceleration Error Constant (Ka) • For a Type 0 system • For Type 1 systems • For type 2 systems • For type 3 or higher order systems
  • 56. Static Acceleration Error Constant (Ka) • For a parabolic input the steady state error ess is
  • 57. Summary of Steady State Errors
  • 58. Example 4 • For the system shown in figure below evaluate the static error constants and find the expected steady state errors for the standard step, ramp and parabolic inputs. C(S)R(S) - ))(( ))(( 128 52100 2   sss ss
  • 59. Example 4 ))(( ))(( )( 128 52100 2    sss ss sG )(lim sGK s p 0            ))(( ))(( lim 128 52100 2 0 sss ss K s p pK )(lim ssGK s v 0            ))(( ))(( lim 128 52100 2 0 sss sss K s v vK )(lim sGsK s a 2 0              ))(( ))(( lim 128 52100 2 2 0 sss sss K s a 410 12080 5020100 . ))(( ))((         aK
  • 60. Example 4 pK vK 410.aK 0 0 090.
  • 61. Ex 5: The open loop transfer function of a servo system with unity feedback is given by Determine the damping ratio, undamped natural frequency of oscillation. What is the percentage overshoot of the response to a unit step input. SOLUTION: Given that Characteristic equation 10 (s  2)(s  5) G(s)  10 H(s) 1 (s  2)(s 5) G(s)  1 G(s)H (s)  0
  • 62. 10  01 s2  7s  20  0 (s  2)(s 5) Compare with s2  2 s 2  0 n n We get *100 1.92% 16 1(0.7826)2  *0.7826 12  2* *4.472 7   0.7826  2 20  e 20  4.472rad /sec M p e n  n 2n  7  n 4.472rad /sec   0.7826 M p 1.92%
  • 63. H (s)  Ks The damping factor of the system is 0.8. Determine the overshoot of the system and value of ‘K’. SOLUTION: We know that 12 G(s)  s2  4s 16 s2  (4 16K)s 16  0 s2  (4 16K)s 16R(s) C(s)  1 G(s)H(s) 16 G(s) R(s) C(s)  is the characteristic eqn. Ex 6: A feedback system is described by the following transfer function
  • 64. nn 2 n 2 Compare with 2 16 s  2 s   0 n  4rad /sec. 2n  4 16K 2*0.8*4  4 16K  K  0 . 1 5 *1001(0.8)2  M p 1.5% *100 eM p  e 0.8 12 
  • 65. Ex 7: The open loop transfer function of unity feedback system is given by SOLUTION: 50 (1 0.1s)(s10) G(s)  Determine the static error coefficients Kp , Kv andKa 50 50 50  0  0  5 lim (1 0.1s)(s10) (1 0.1s)(s10) K  lims.G(s)H (s) K  limG(s)H(s)  lim s2 s0 2 Ka  s G(s)H (s)  lims. s0 s0 v s0 (1 0.1s)(s 10) s0 p