1. SENIOR TEST ENGINEER – CV
Engr Gauthaman kanagasabai
knggauthaman@gmail.com;
Mobile: +966532518103
PERSONAL DETAILS:
Name : GAUTHAMAN
Date of Birth : 05th
0CT 1976
Nationality : Indian
Sex : Male
Languages Known : Tamil, English and Hindi
PASSPORT DETAILS:
Passport Number : G9401704
Date of Issue : 10.07.2008
Valid up to : 09.07.2018
EDUCATIONAL QUALIFICATION
Professional : B.E. (Electrical & Electronics Engg)
Institute : Annamalai University,Chithambaram.
Year of Completion : MAY 2004
2. PROFESSIONAL EXPERIENCE: 10 Years
Sr. Testing and commissioning Engineer in Voltech Pvt Ltd.,
Sr. Testing and commissioning Engineer in T&C Pvt Ltd.,
Testing and Commissioning Engineer in SEP Pvt Ltd.,
FIELD EXPERIENCE: TESTING AND COMMISSIONING
Testing & Commissioning:
Testing and commissioning up to 400KV indoor/Outdoor substation and
substation equipment’s.
Stability checking of Power transformers, Generator, HT Motors.
Testing and commissioning of Power Transformers up to 315MVA.
Testing and commissioning of Generator 8.27MW.
Testing & Commissioning of Static and Numerical Protection Relays of
various types of leading makes.
Testing & Commissioning of Static substation equipment’s with all type of
switchgears SF6GCB, VCB, and ACB’s.
Maintenance testing of relays, Breaker and calibration of Elec. Meters.
Preparation of cable schedule and termination schedules.
Trouble shooting of various electrical systems schemes at different type of
process Plants and power plants.
High potential test on cables & bus bar
Interlock scheme check
ACDB panels testing
DCDB panels testing
Lighting panels testing
Scheme & functional check of all control & relay panels up to 400 KV SS.
3. Testing & commissioning of complete switchgears & switchyards up to 400
KV SS.
Substation equipments:
Current Transformer: Winding Resistance, Ratio, and Knee point,
Polarity Test, Insulation Resistance, Contact Resistance and Tan-delta.
Voltage Transformer: Winding Resistance, Ratio, Polarity
Test, Insulation Resistance, Contact Resistance and Tan-delta.
Capacitive Voltage Transformer: Insulation Resistance, Winding
Resistance, Ratio, Polarity Test, Contact Resistance and Tan-delta.
Circuit Breakers: Insulation Resistance, Contact Resistance, Timer and
Dynamic Contact Resistance.
Isolator: Insulation Resistance and Contact Resistance.
Surge arrestor: Insulation Resistance and Tan-Delta.
HI-POT TEST: Cable, Bus-Bar and Generator.
Generator: Insulation Resistance, Winding Resistance and Contact
Resistance.
Transformer: Winding Resistance, Insulation Resistance, Ratio, polarity,
Vector Group, Magnetic balance Test, Magnetization Current Test and
Contact Resistance.
Motor: Insulation Resistance, and Winding Resistance.
Auxiliary, Trip, Timer and Super Vision Relays: TR241, TR212, XR35x,
RXSF1, RXMVBx, AND RXKL etc.,
4. I have handled with the following jobs in successfully:
Projects in India:
1. Testing & commissioning of 8.27 MW Generator,11/0.433 kV
Switchgear including Protection, cable schedule preparation, control
scheme preparation & overall scheme checking for M/s. BCW Ltd.,
Thiruchendur through M/s. APT Ltd.,
2. Testing & commissioning of different Electrical equipments such as
Power Transformer, CTs, PTs, Circuit Breakers, Isolators, Protection
Relays Protection, overall scheme checking, Cable Schedule
preparation for 33/11/.433 KV Switchgear and its protective relays
for M/s. SAIL., Rourkela through M/s. BOC Ltd.,
3. Testing of contact resistance test for 400/220 KV GIS Substation
for NTECL., Chennai through M/s. L&T Ltd.,
4. Testing of winding resistance test for 400 KV Shunt Reactor for
PGCIL., Karnataka through M/s. KOJHER Enterprises Ltd.,
5. Testing overall scheme checking of 132/6.9/0.433 KV Substation
equipments such as Power Transformers, CTs, PTs, Circuit
Breakers, Isolators and its protective relays for Ultra Tech Cements
Ltd., Andhra Pradesh through M/s. ABB Ltd.
6. Testing & commissioning and overall scheme checking of 400/220
KV Substation equipments such as Power Transformers, CTs, Cvts,
Circuit Breakers, Isolators and its protective relays for PGCIL Bina
through M/s. G.E.T Power Private. Ltd
7. Testing & commissioning and overall scheme checking of 400/220
KV Substation equipments such as Power Transformers, CTs, Cvts,
Circuit Breakers, Isolators and its protective relays for PGCIL
Gwalior through M/s. G.E.T Power Private. Ltd.
8. Testing & commissioning of 2x60MW Generator,11/0.433 kV
Switchgear including Protection, cable schedule preparation, control
5. scheme preparation & overall scheme checking for GEPL
Chandrapur through M/s. G.E.T Power Private. Ltd.
9. Testing & commissioning and overall scheme checking of 33KV
Substation equipments such as Lighting Transformers, CTs, PTs,
Circuit Breakers, Isolators and its protective relays for PGCIL Bina
through M/s. G.E.T Power Private. Ltd
10. Testing & commissioning and overall scheme checking of 400/220
KV Substation equipments such as Power Transformers, CTs, Cvts,
Circuit Breakers, Isolators and its protective relays for PGCIL
Gwalior through M/s. G.E.T Power Private. Ltd.
11. Testing & commissioning of 2x60MW Generator, 11/220kv
substation including Protection, cable schedule preparation, control
scheme preparation & overall scheme checking for GEPL
Chandrapur through M/s. G.E.T Power Private. Ltd.
Projects in Saudi Arabia:
1. Testing & commissioning and overall scheme checking of 132/13.8
KV Substation cable schedule preparations, Aux. relays. Lockout
relays, tripping relays, bi-stable relays for SEC 8906s/s HAIL
through M/s. AL-GIHAZ.
2. Testing & commissioning and overall scheme checking of 132/13.8
KV Substation cable schedule preparations, Aux. relays. Lockout
relays, tripping relays, bi-stable relays for SEC 9030s/s HAIL
through M/s. AL-GIHAZ.
3. Updated scheme modification of 132/13.8 KV Substation SEC
8145s/s Riyadh through M/s. AL-BABTAIN CO. Ltd.
4. Updated scheme modification of 132/13.8 KV Substation SEC
8142s/s Riyadh through M/s. AL-BABTAIN CO. Ltd.
5. Updated scheme modification of 132/13.8 KV Substation SEC
8150s/s Riyadh through M/s. AL-BABTAIN CO. Ltd.
6. Updated scheme modification of 132/13.8 KV Substation SEC
8146s/s Riyadh through M/s. AL-BABTAIN CO. Ltd.
6. 7. Testing & commissioning and overall scheme checking of 132/13.8
KV Substation cable schedule preparations relays. Lockout relays,
tripping relays, bi-stable relays for SEC 8042s/s Riyadh through
M/s. CEPCO.
8. Testing & commissioning and overall scheme checking of 132/13.8
KV Substation cable schedule preparations relays. Lockout relays,
tripping relays, bi-stable relays for SEC 8152 s/s Riyadh through
M/s. CEPCO.
9. Testing & commissioning and overall scheme checking of 132/13.8
KV Substation cable schedule preparations, P546 Line Diff.
relay,Aux. relays. Lockout relays, tripping relays, bi-stable relays for
SEC 8079s/s Riyadh through M/s. TDP.
10. Testing & commissioning and overall scheme checking of
132/13.8 KV Substation cable schedule preparations, 7sd5222 Line
Diff. relay,Aux. relays. Lockout relays, tripping relays, bi-stable relays
for SEC Al-Bada s/s through M/s. Algihaz.
TESTING KNOWLEDGE OF NUMERICAL RELAYS:
Siemens Make : 7SD522 – 87L & 21L Relay
7SJ64 – O/C & E/F Relay
7VK61 – CBF RELAY
7SA522 – 87L & 21L Relay
Alstom Make : MICOM – P546 - 87L & 21L Relay
MICOM – P545 - 87L & 21L Relay
MICOM – P443 - 21L Relay
MICOM – P643 – 87T
MICOM – P142 – O/C & E/F Relay
MICOM – P139 – O/C & E/F Relay
MICOM - P143 - SYN. RELAY
MICOM – P841 – A/R Relay
SEL MAKE : 411L-87L, 387E – 87T
SEL-451 O/C & E/F Relay
GE : L90 - 87L & 21L Relay
D60 - 21L Relay
7. GE-C70 O/C & E/F Relay
ABB : REF615 CBF, O/C & E/F Relay
Auxiliary, Trip, Timer and Super Vision Relays: TR241, TR212, XR35x,
RXSF1, RXMVBx, A400 AND RXKL etc.,
TEST EQUIPMENT HANDLED: FREJA 300, ISA DRTS, OMICRON-CPC100
CP-TD1TAN-DELTA, SVERKER, SCOPE-Winding Resistance, Contact
Resistance and Timer
Declaration
I, hereby declare that all the information stated above is true to the
best of my knowledge.
Place:
Date: (GAUTHAMAN.K).