1. volume 39 ● issue 19
T E S T & M E A S U R E M E N T
Rental Solutions Guide
techrentals
your rental business partner
Y E A R S
2. 1800 632 652
www.techrentals.com.au
rent@techrentals.com.au
Office Locations
TechRentals Australia
Adelaide
169 South Road
Ridleyton
South Australia 5008
P 08 8302 8800 | F 08 8302 8899
Brisbane
72 Donaldson Road
Rocklea
Queensland 4106
P 07 3717 9100 | F 07 3077 8872
Darwin
Unit 3, 101 Coonawarra Road
Winnellie
Northern Territory 0820
P 08 8947 2860 | F 08 8947 2901
Melbourne
18 Joseph Street
Blackburn North
Victoria 3130
P 03 9896 3000 | F 03 9896 3099
Newcastle
Unit 2, 1 Hartley Drive
Thornton
New South Wales 2322
P 02 4966 5910 | F 02 4966 3586
Perth
122 Kewdale Road
Kewdale
Western Australia 6105
P 08 9441 3900 | F 08 9441 3999
Sydney
41 Enterprise Circuit
Prestons
New South Wales 2170
P 02 8777 0800 | F 02 8777 0877
Townsville
Unit 2, 14 Blackhawk Boulevard
Thuringowa Central
Queensland 4817
P 07 4773 7788 | F 07 4723 5397
TechRentals
Malaysia
603 5632 1135
www.techrentals.com.my
SELANGOR D.E
38 Jalan PJS 11/3 Bandar Sunway
46150 Petaling Jaya
Selangor Darul Ehsan
Malaysia
P +60 3 5632 1135
F +60 3 5632 5409
TechRentals
New Zealand*
0800 832 475
www.techrentals.co.nz
AUCKLAND
669 Great South Road
Penrose Auckland
New Zealand
P +64 9 589 2030
F +64 9 589 2031
*distributor of TechRentals
Australia
TR VMS
(Calibration - Repair - Sales)
BRISBANE
72 Donaldson Road
Rocklea
Queensland 4106
P 07 3717 9100
F 07 3717 9148
SYDNEY
41 Enterprise Circuit
Prestons
New South Wales 2170
P 02 8777 0800
F 02 8783 5171
PENANG
1-10-07, Suntech @ Penang
Cybercity (1264)
Lintang Mayang Pasir 3
11950 Bayan Baru
Penang
P +60 4 619 2641
F +60 4 619 2643
3. Contents
Your trusted partner in
technology. Offering
innovative solutions through
our leading brands: techrentals vidcom telecom
Save your time and reduce
your real costs. Find out all
about our Configuration and
Download solutions on page 43.
Visit TechRentals Wiki
This resource centre provides manuals,
technical information and how-to videos.
www.techrentals.com.au
select Technical Tips and Videos.
1. stretch your budget
Test equipment is often used just some of the time. Rental allows
you to pay for it only when you use it, as well as stretching your
budget by accessing more equipment than you could if you
purchased it outright.
2. utilise operating expense
Test equipment is expensive often sitting on a shelf collecting
dust – not an effective use of your valuable business capital.
Rental allows you to free up cash for other parts of the business
where it can be used to generate additional profits.
3. conduct product research before purchasing
It is not always clear immediately which make and model will fulfil
your requirements best. Trialling it on casual rental gives you
hands-on experience to guide purchase decisions.
4. recover costs more quickly
Generally rental payments are fully tax deductable and the
expense can be recovered far more quickly than the tax
allowances for ongoing asset depreciation.†
5. eliminate running costs
The expense of maintaining, calibrating and warehousing your
test and measurement equipment can be high. With rental you
avoid these costs, as well as freeing up storage space within your
premises.
6. cost allocation is simplified
Rental payments are easy to track and account for in your
business, making it easy to allocate appropriate costs to
departments, clients or specific projects.
7. respond to sudden demands
At peak periods, for unexpected projects, or when essential
equipment breaks down, rental can put the necessary equipment
in your hands ensuring seamless operations.
8. apply new technologies & avoid obsolescence
Rental allows you to update your equipment in line with other
businesses and take advantage of new technologies. It also
avoids the potential cost of owning equipment that can be quickly
superseded.
9. preserve credit
Renting avoids the potential cost of utilising credit facilities
such as an overdraft or credit cards, which are often used for
equipment purchases.
10. technical support
When you rent from TechRentals you’ll have the support of an
experienced team of product experts, who’ll help you get the most
from your equipment. And in the unlikely event of equipment failure
we will do our utmost to rectify the issues as soon as possible.
†
Please ensure you obtain independent professional taxation advice.
Why rental makes good sense General Index 2, 3 & 4
Manufacturers Index 5, 6 & 7
Electronics 8-13
Radio Frequency 14-19
Data &
Telecommunications 20-23
Electrical Power 24-37
General Industrial & Process
Measurement 38-51
Physical Measurement 52-57
Construction, Building
Services & Survey 58-62
Environmental, OHS,
Chemical & Laboratory 63-69
Other Products 70
hirecom
1
4. General Index
A
AC See Electrical Power
AC Sources/Inverters/Generators 36
Accelerometer 55
Adhesion Tester 52
Air
Flow 58, 59, 65
Quality 58, 59, 65
Air Balancing Hood 58
Air Conditioner Valve Balancing 59
Air Conditioning
Coolant Flow 69
Electronic Manifold 59
Measurement 58
Valve Balancing 59
Ventilation Meter 59
Air Conditioning & Air Flow 58
Air Quality
Monitoring 58, 63, 64, 65
Particles 64, 65
Pressure & Humidity 58, 65
Air Quality & Heat Stress 65
Airborne Dust & Particle Meter 64
Alignment 42, 55
Anemometer 58, 59
Antenna & Cable Test 16
Antennas 19
Appliance Tester 25
Area Heat Stress 65
Audio Analysers 18
B
Balances 55, 69
Balances & Scales Below 8kg 69
Balancing Machinery 59
Balometer 58
Barometric Loggers 68
Bath
Constant Temperature 42
Ultrasonic 50
Battery Management Systems 36
Blast Loggers 56
Body Vibration Measurement 55, 56
Bore Hole Water Quality 67, 68
Borescopes 41
Bridge LCR 10
C
Cable
Fault Locator 24
LAN Test 20
Locator 20, 24, 61
Tester 20
Cable & Fault Locators 61
Cable & Pipe Tracers & Fault Locators 24
Cable Analysers 20
Cable Locators 61
Calibrators
Current 11, 42, 45
Current Loop 11, 42, 44, 45
Dry Block Temperature 42, 45
Electronic 11
Fitting Set 44
Hydraulic 42, 43, 45
Industrial 42, 45
Intrinsically Safe Loop 43
Laboratory 45
Loop 42, 45
Pneumatic Instruments 42, 45
Pressure 42, 43, 44, 45
Process 42, 44, 45
Resistance 11, 42, 44, 45
Temperature 42, 45
Voltage 11, 42, 44, 45
Camera
Endoscope 41
High Speed 41
Pipe Inspection 41, 61, 62
Thermal Imaging 39, 40
Video 41
Carbon Dioxide (CO2) 50, 63, 65
Carbon Monoxide & Nitrogen Dioxide Monitors 63
Carbon Monoxide (CO) 50, 63, 64, 65
Cat 5, 5E, 6 20
Charge Amplifier 55
Chart Recorders 45, 49
Chemical & Analytical 69
Circuit Breaker Analyser System 34, 35
Circuit Breaker Testers 34
Circuit Tracer 24
Clamp-on Sensors 31
Clean Room Monitor 64
Cleaver - Fibre Optic 23
Coating Thickness 52, 54
Combustion Gas Analysis 50
Combustion, Flue & Industrial Gas Analysers 50
Communication Test Sets 16, 18
Compressor Output
Flow 65
Quality 65
Concrete Cover Meters 59
Concrete Hardness Testers 60
Concrete Testing
Adhesion 52
Corrosion 60
Cover Meters 59, 60
Moisture Meters 62
Reo Depth 60
Test Hammer 60
Concrete Testing Equipment 59
Concrete Thickness Gauges 59, 60
Conductivity & Salinity 68
Confined Space Entry 63, 64
Construction, Building Services & Survey 58
Air Conditioner Valve Balancing 59
Air Conditioning & Air Flow 58
Concrete Testing Equipment 59
Distance Measurement & Surveying 62
Ground Penetrating Radar 61
Material Moisture Meters 62
Pipeline & Cavity Inspection 61
Underground Services Location 61
Utility Leak Detection 61
Counting Scales 55, 69
Crane Scales 54, 55
Current
Clamp 28, 30, 31, 32, 36
DC Source 10
Injection 35
Input Logger 47
Loop 42, 44, 45
Meter 28, 31, 49, 69
Primary Injection 35
Probe 10, 24, 31, 32
Secondary Injection 35
Transformer (CT) 31
Current Clamps Probes & Accessories 31, 32
Current Injectors 35
Current Transformer Testing 34
D
Data & Telecommunications 20
Cable Test 20
DSL/POTS Test Set 22
Ethernet Analysers 20
Ethernet Loopback 20
Ethernet Test Set 20
Etherscope 20
Fibre Optic Launch Cables & Patch Leads 23
Fibre Optics 23
Fusion Splicers 23
LAN Analysers 20
LAN Cable Testers 20
LAN/WAN Analysers 20
Light Source 22
Light Sources & Power Meters 22
OTDR & Fibre Inspection 23
PDH/SDH Analysers 21
Permanent Link Adaptors 20
WAN Analysers 20
Data Loggers 47, 48
DC High Voltage 10, 31, 32, 33
DC Power Supplies 10
DC Power Supplies & Loads 10
Decade Resistance Box 11, 45
Demand Analysers 27
Dewpoint 65
Digital Storage Oscilloscopes 8, 10
Dissolved Oxygen 67
Distance Measurement 62
Distance Measurement & Surveying 62
Distortion Analysers 18
Dry Block Calibrators 45
DSL/POTS 22
DSn/PDH Ethernet Analyser 22
Ductor 25, 27
Dust Measurement 64, 65
E
E & H Field Strength Meters 11
E1/E3 Tester 21, 22
Earth Leakage 25, 32, 33, 34
Earth Testers 25
Electrical Cable Test 25, 32, 33, 34
Surge Generator 24
TDR 24
Electrical Installation & Test
Appliance Tester 25
Earth Leakage (RCD) 25, 32, 33, 34
High Voltage Test (Hipot) 32, 33
Insulation Oil Tester 33
Insulation Test 24, 25, 32, 33, 34
Resistance Test 25, 27, 32
Soil/Ground Resistance 25
VLF Testers 33
Electrical Power 24
AC Sources/Inverters/Generators 36
Battery Management Systems 36
Cable & Pipe Tracers & Fault Locators 24
Circuit Breaker Testers 34
Current Clamps Probes & Accessories 31
Current Injectors 35
Electrical Testers 24
Insulation Testers & Meggers to 20kV 32
Micro-Ohm Meters & Earth Testers 25
Oil, Hipot & VLF Testers above 20kV 33
PAT Testers & RCD Testers 25
Power Analysers & Recorders 27
Power Transformers & Variacs 36
Protection Relay Testing Systems 35
Transformer Testers 34
Electrical Power Generation & Transmission
Current Injection 35
High Voltage Test (Hipot) 33
Power Quality 24, 27, 28, 30, 31
Protection Relay Test 34, 35, 36
Electrical Power Quality
Harmonics 24, 27, 30, 31
Power Factor 24, 27, 30, 31
Power Logger 28
Power Quality Analysers 27, 28, 30, 31
Electrical Power Sources
Battery Management Systems 36
Current Injectors 35
Programmable 36
Electrical Testers 24
Electrical Transducers 24
Electrochemistry 67
Electrometers 8
Electronic Calibrators 11
Electronic Load 10
Electronics 8
DC Power Supplies & Loads 10
Digital Storage Oscilloscopes 8
E & H Field Strength Meters 11
Electronic Calibrators 11
EMC & Power Disturbance Simulators 12
Function Generators 10
Gauss/Tesla Meters 11
LCR Meters 10
Multimeters& Electrometers 8
Probes & Accessories 10
Spectrum Analysers - Low Frequency 11
TV Test Equipment 11
Electrostatic Charge Measurement 8
Electrostatic Meters 8
EMC & Power Disturbance Simulators 12
EMC Test Equipment 12
EMC/EMI Test Equipment 12
Endoscopes 41, 61
Endoscopes Borescopes Visual Inspection 41
Environment, OHS, Chemical & Laboratory
Air Quality & Heat Stress 65
Airborne Dust & Particle Meters 64
Balances & Scales below 8kg 69
Chemical & Analytical - General 69
Environmental Gas & Vapour Meters 63
Environment Flow Meters 69
Floor Slip Testers 67
Laboratory Instruments, Spectroscopy 69
Light Meters, UVA/B/C Measurement 68
2
5. General Index cont’d.
Moisture & Humidity Meters 65
Noise & Sound Analysers 65
Personal Gas & Vapour Monitors 64
Radiation Monitoring & Protection 66
Water Quality, pH Meters & Electrochem 67
Weather Stations 68
Environmental , OHS, Chemical & Laboratory 63
Environmental Chambers/Ovens 50
Environmental Flow Meters 69
Environmental Gas & Vapour Meters 63
Environmental Noise 65
Environmental Noise Loggers 65, 66
Environmental Test Chambers/Ovens 50
Ethernet Loopback 20
Ethernet Test Set 20
Excavator Cable Locators 61
F
Fault Locators 24, 61
Fault Loop Impedance Tester 25
Fibre Inspection & Test Kit 23
Fibre Inspection-Capture Probe 23
Fibre Optic Launch Cables & Patch Leads 23
Fibre Optics 23
Cleaver 23
Fibrescope 61
Field Strength Meters 11
Flaw Detector 52
Floor Slip Testers 67
Flow Hood 58
Flow Meters 49, 50, 69
Compressed Air 49
Doppler 49, 50
Gas 49
Liquid 49, 50, 69
Non-Intrusive 49, 50
Open Channel 49, 69
Transit Time 49, 69
Ultrasonic 49, 50, 69
Flow Meters for Liquids & Gases 49
Flue Inspection 41, 62
Force Gauges 54
Formaldehyde Meters 63
Frequency Counters 14
Frequency Response Analysers 34
Function Generators 10
Fusion Splicers 23
G
Gamma Radiation 66
Gas 63
Carbon Dioxide (CO2) 50
Carbon Monoxide (CO) 50
Flammable (LEL) 63, 64
Formaldehyde 63
Hydrogen Sulphide (H2S) 63, 64
Methane (CH4) 63
Nitric Oxide (NO) 50
Nitrogen Dioxide (NO2) 50
Oxygen (O2) 50, 63
Ozone (O3) 63
Petroleum Hydrocarbons 63
Refrigerant 63
SF6 64
Sulphur Dioxide (SO2) 63
VOC 63, 64
Gas & Vapour Meters 63
Gas Analysis & Monitoring 50, 63, 64
Gauss/Tesla Meter 11
General Industrial & Process Measurement 38
Combustion, Flue & Industrial Gas Analysers 50
Data Loggers 47
Dry Block Calibrators 45
Endoscopes Borescopes Visual Inspection 41
Environmental Test Chambers/Ovens 50
Flow Meters for Liquids & Gases 49
High Speed Video Inspection Cameras 41
High Speed Waveform Recorders 46
Industrial Process Calibrators 42
Infrared Thermal Imaging Cameras 39
Laser Rotational Shaft Alignment 42
Pressure & Humidity Transducers 49
Pressure Vacuum Gauges/Recorders 49
Strip Chart Recorders 45
Tachometers/Stroboscopes 41
Temperature Meters/IR Thermometers 38
Ultrasonic Baths 50
Ground Penetrating Radar 61
H
Hardness Testers 52
Harmonics (Power) 27, 28, 31
Hart Communicators 43
Heat Stress 65
High Frequency Spectrum Analysers 14, 16
High Speed Video Cameras 41
High Speed Video Inspection Cameras 41
High Speed Waveform Recorders 46
High Voltage Insulation Dielectrics Test Set 33, 34
Hipot Testers 32, 33
Holiday Detector 52
Hot Wire Anemometer 58, 59
Humidity
Chamber 50
Concrete 59
Indoor Air 65
Logging 47, 48
Natural Gas 65
Thermohygrograph 65
Transducers 49
Weather 68
HVAC & IAQ 58, 59, 65
Hybrid Recorders 46
Hydraulic Pressure 42, 43, 52
I
Illuminance Meter 68
Inclinometers 54
Indoor Air Quality 65
Industrial Process Calibrators 42, 45
Infrared Cameras 39, 40
Infrared Thermal Imaging Cameras 39
Infrared Thermometers 38
Injection Test Sets 35
Instrumentation Amplifiers 45, 46
Insulation Diagnostic Analysers 34
Insulation Testers 25, 32
Insulation Testers & Meggers to 20kV 32, 33
Intrinsically Safe
Current Loop Calibrators 42
Gas Monitors 63, 64
Moisture Analysers 65
Photo-Ionisation Detector (PID) 63, 64
IR Thermometers 38
L
Laboratory Ovens 50
LAN
Analysers 20
Cable Certification 20
Cable Testers 20
LAN Analysers/Management 20
LAN Cable Testers 20
LAN/WAN Analysers 20, 21
Landfill Gas Monitors 63
Laser
Distance & Speed 56, 62
Laser Pipe Alignment System 42
Laser Rotational Shaft Alignment 42
LCR Meters 10
Leak Detectors
Gas Pipe 61, 63, 64
Microwave Oven 66
Refrigerant 63
Water 61
Light Measurement 62, 68
Light Meters, UVA/B/C Measurement 68
Light Source 22
Light Sources & Power Meters 22
Linear Position Transducers 54
Liquid Flow Loggers 69
Liquid Flow Meters 49
Load Cells 54
Logger
Accessories 47
Autoclave 47
Data 47, 48
Explosion 56
Flow 49
Humidity 47, 48
Temperature 47, 48
Loggers See also Recorders
Low Frequency Spectrum Analysers 11
Luminance Meter 68
Lux Meter 68
M
Machinery
Balancing 55
Vibration 55, 56
Magnetic Field Meters 11
Manometers 58, 59
Material Hardness Testers 52
Material Moisture Meters 62
Material Testing 69
Memory Recorders 46
Metal Detectors 70
Methane Monitors 63
Micro-Ohm Meters 25, 27
Micro-Ohm Meters & Earth Testers 25
Microwave Leakage Detectors 66
Microwave Oven Survey Meters 66
Modified Atmosphere
Packaging Test 50, 63
Moisture
Concrete 62
Timber 62
Wood 60
Moisture & Humidity Meters 65
Moisture Analysers 65
Moisture Balance 69
Multimeters 8
Multimeters & Electrometers 8
N
Natural Gas 65
Network Analyser
Antenna & Cable Test 16
Cable Test 16
Power 27, 30
RF 16
Network Analysers 16
Network Analysers/Antenna & Cable Test 16
Noise & Sound 65
Noise & Sound Analysers 65
Noise Loggers 65, 66
Non-Destructive Testing (NDT) 52, 54
O
Occupational Health & Safety 63
Air Quality 58, 59, 65
Appliance Testing 25
Confined Space Entry 63, 64
Floor Slip Testers 67
Formaldehyde 63
Heat Stress 65
Lighting 68
Noise & Sound 65
Ozone 63
Radiation 12, 66, 67
UV Exposure 68
Vibration 55
Volatile Organic Compound (VOC) 63
Oil Insulation Testers 33, 34
Oil, Hipot & VLF Testers Above 20kV 33
Optical Power Meter 22
Oscilloscopes
Digital Storage 8, 10
Portable 8
OTDR 23
OTDR & Fibre Inspection 23
Oven 50
Oxygen & CO2
Analysers 50, 63, 64
Oxygen (O2
) 50, 63, 64
Ozone (O3
) 63
P
Pancake Load Cell 55
Particle Counters 64
PAT 25
PAT Testers & RCD Testers 25
PDH Analysers 21
PDH/SDH Analysers 21
Permanent Link Adaptors 20
Personal Gas & Vapour Monitors 64
Petrochemical Contamination 63
pH Measurement 67
pH Meters 67
pH reading for Meat Standards 67
pH, mV & Temperature Measurement 67
Photo-Ionisation Detector (PID) 63, 64
3
6. General Index cont’d.
Physical Measurement 52
Force Gauges 54
Inclinometers 54
Load Cells 54
Material Hardness Testers 52
Non-Destructive Testing 52
Position Transducers 54
Speed Measurement 56
Vibration Analysis 55
Weighing & Counting Scales Over 8kg 55
Pinhole Detector 52
Pipe Locators 61
Pipeline & Cavity Inspection 61
Pipeline Camera Inspection System 61
Pipeline Inspection 41
Pitot Tube 58
Probes & Accessories 10
Portable Appliance Testers 25
Position Transducers 54
POTS 22
Power See Electrical Power
Power Analysers 27
Power Analysers & Recorders 27, 28
Power Demand Analysers 27
Power Disturbance 24, 27, 30, 31
Power Loggers 28, 31
Power Meter - RF 18
Power Meters 18
Power Meters & Sensors 18
Power Supplies - DC 10
Power Transformer Testers 34
Power Transformers 36
Pressure
Calibrator 42, 43, 44, 45
Circular Chart Recorder 49
Indicator/Gauge 49
Logging Gauge 49
Transducers 49
Pressure & Humidity Transducers 49
Pressure Calibrators 44
Pressure Recorders 45
Pressure Transducers 44
Pressure Vacuum Gauge/Recorders 49
Primary & Secondary Test Systems 34, 35
Probes
Current 10, 24, 31, 32, 36
High Voltage 10
Line Logic 46
Process Calibrators 44, 45
Profibus 44
Prospecting Metal Detectors 70
Protection Relay Test 34, 35, 36
Protection Relay Testing Systems 35
Pulse Porosity Detectors 52
Pumps 42, 43, 45
R
Radar Speed Gun 56
Radiation Monitors 12, 66, 67
Radiation Monitoring & Protection 66
Radio Frequency 14
Antennas 19
Communication Test Sets 16
Distortion Analysers 18
Frequency Counters 14
Network Analysers/Antenna & Cable Test 16
Power Meters - RF 18
RF Accessories 19
RF Amplifiers 19
RF Attenuators 19
RF Signal & Sweep Generators 14
Spectrum Analysers - High Frequency 14
Radiometers 68
RCD Test 25, 32
Recorders 47
Chart 45, 49
Hybrid 46
Memory 46
Pressure 45, 49
Refrigerant Leak Detection 63
Relay Test 35, 36
Resistance
Calibration 11, 42, 45
Decade 11, 45
Ground/Soil 25
Micro-Ohm 25, 27
Static 32
Tester 25, 32, 33, 34
RF See also Radio Frequency
RF Accessories 19
RF Amplifiers 19
RF Attenuators 19
RF Signal & Sweep Generators 14
RF Sweep Generators 14
Rotating Balancing 55, 56
RTD Calibrator 42
S
Safety Bolt Inspection System 54
Salinity & Conductivity 68
Scales 54, 55, 69
Scopemeters 8
SDH Analysers 21
Security
Metal Detectors 70
Security Equipment 70
Sensors - RF 18
Shaft Alignment 42, 55
Shaker Table 55
Signal Generators 14
RF 14
Smoke Generating Machine 58
Soil Resistivity 25
Sound
Dose Meter 66
Measurement 65
Signal Analysis 65
Sound Level Meter 55, 56, 65, 66
Vibration 55, 56
Spectrophotometer 69
Spectroscopy 69
Spectrum Analysers
High Frequency 14, 16
Low Frequency 11
RF 11, 14, 16
Spectrum Analysers – Low Frequency 11
Spectrum Analysers – High Frequency 14
Speed Measurement 56
Splicer - Fibre Optic 23
Startup Current 28, 30, 31, 32
Static Discharge Generators 12
STM1 ... STM64 21, 22
Strip Chart Recorders 45
Stroboscope 41
Surge Generators 24
Surge Transient Generator
EMC/EMI Test 12
Sweep Generators 14
T
Tachometers 41
Tachometers/Stroboscopes 41
Tan Delta Measurement 33, 35
TDR 24
Telecommunications 20, 21
Access Tester 21
Analysers 21
CDMA 18
Data Tester 21
PDH 21
POTS 22
SDH 21
Temperature
Humidity Loggers 48
IR Thermometers 38
Logging38
Probe 38
Thermocouple 38
Thermometers 38, 39
Temperature Bath 45
Temperature Meters 38
Temperature Meters/IR Thermometers 38
Tension 54
Test & Tagging 25
Test Chambers 50
Thermal Imaging Cameras 39, 40
Thermocouples 38
Thermohygrograph 65
Thickness Gauges 52
Time Domain Reflector
TDR 24
Torque Wrench 54
Total Dissolved Solids (TDS) 68
TPH Monitor 63
Tracking Generator 14
Transducers
Electrical 24
Humidity 49
Position 54
Pressure 49
Temperature 49
Transformer Testers 34
Transient Burst 12
Transport
Inclinometers 54
Turbidity 67, 68
TV Analyser 11
TV Test Equipment 11
U
Ultrafine Particle Counter 64
Ultrasonic Baths 50
Ultrasonic Probe 52
Underground Services Location 61
Utility Leak Detection 61
UV Exposure 68
V
Valve Balancing (Air Conditioning) 59
Variacs 36
Vehicle Volume & Speed Counters 56
Ventilation Meters 59
Vibration
Accelerometer 55
Analyser 55, 56
Blast Logging 56
Table 55
Whole Body 55
Vibration Analysis 55
Vibration Loggers 56
Video
Endoscope 41
High Speed 41
Pipeline Inspection 41, 61
Viscometer 69
Visual Inspection 41, 61, 62
Visual Inspection Equipment 41
VOC Monitors 63
Volatile Organic Compounds (VOC) 63, 64
Voltage Calibrators 42, 45
W
Walk Through Metal Detectors 70
WAN Analysers 20
Water
Conductivity 68
Depth 49, 67, 68, 69
Depth Measurement 67
Flow 49, 50, 69
pH 67
Quality 67
Sampling 67
Water Quality, pH Meters & Electrochem 67
Water/Oil Bath Temperature Calibrators 42
Water/Oil Temperature Bath 45
WBGT 65
Weather 68
Weather Stations 68
Weighing & Counting Scales Over 8kg 55
Wet & Dry Block Calibrators 45
Wind Speed & Direction 59, 68
Wind Turbine Lightning Protection Test Lead Set 27
Winding Transformer Meter 34
Wood & Masonry Testing
Moisture Meter 60
Workplace Safety See Environmental & OHS
X
X-Ray Measurement 66
4
10. 8
Electronics
Multimeters & Electrometers
Digital Storage Oscilloscopes
Probes & Accessories
Function Generators
LCR Meters
DC Power Supplies & Loads
Spectrum Analysers - Low Frequency
TV Test Equipment
Electronic Calibrators
Gauss/Tesla Meters
E & H Field Strength Meters
EMC & Power Disturbance Simulators
See also Electrical Testers on page 24
Fluke 28II EX Intrinsically Safe
True-RMS Multimeter
FLU,28II-EX AU
Intrinsically Safe Multimeter is a completely sealed IP67
rated case. For use inside and outside of hazardous
zones. Measures up to 1000V, 10A AC and DC with
true-RMS for accurate measurement on nonlinear
signals. Frequency measurements to 200 kHz, resistance, conductance,
diode test, capacitance, and temperature. Results are displayed on the
bright, 4-1/2 digit LCD (20,000 counts).
Fluke 87-5 Industrial True-RMS Multimeter
with Thermometer
FLU,87-5 MY
Unique function for accurate voltage and frequency
measurements on adjusatable speed motor drives and other
electrically noisy equipment.True-RMS AC voltage and
current for accurate measurements on non linear signals.
Built in thermometer. Measure up to 1,000VAC and DC.
Measure up to 10A (20A for 30 seconds). 10,000uF capacitance range.
Frequency to 200kHz and % duty cycle. Peak capture to record transients
as fast as 250μs. 4½ digit mode.
Fluke 289 True-RMS Logging Multimeter
with FlukeView Software
FLU,289 FLUKEVIEW (1209) AU
Complete with a built-in data logger to record
measurements unattended. Internal memory allows
stand-alone logging for up to 180 hours. True-RMS
50,000-count ¼ VGA dot matrix display. 0.025% Basic
DC accuracy. CAT III 1000 V/CAT IV 600 V safety rated.
Supplied with FlukeView software and download cable.
See also Data Loggers on page 47-48
Agilent/HP 34401A Digital Multimeter
HP,34401A (1200) AU
Precision 6½ digit multimeter. 100nV sensitivity on
DC 120mV range. Max DC input 1kV. Measures
AC voltage, DC & AC current to 3A, 2 or 4 wire
resistance to 120MΩ, period & frequency. Max reading rate 1,000/s. Maths
functions including limits test. 512 point storage. RS232 & HPIB interfaces.
Vermason 222541 Electrostatic Meter
VER,222ES (1246) AU
Electrostatic meter for periodic audits of facilities,
monitoring packaging, materials, machines and other
electrostatic generative equipment or processes. This
precision field meter is designed to measure electrostatic
voltage potentials over selected distances from 1 to 20cm.
Range at the standard distance of 2cm is 20kV. Two range
3 digit display in V or kV.
Digital Storage Oscilloscopes
Agilent DSOX3024A
Oscilloscope 200MHz
4 Channels
AGI,DSOX3024A (1350) AU
4 channel 200MHz digital storage oscilloscope.
Sampling rate 2 G/s (4 G/s half-channel interleaved mode). 2Mpts memory
depth, waveform update rate 1 million waveforms/s, sensitivity 1mV/div to
5V/div and 16 digital channels. Built-in 20 MHz function/arbitrary waveform
generator. Pass/fail masks can be automatically created based on an input
reference waveform or on a PC then imported via USB, also store and remove
waveforms via USB.
Agilent MSOX3024A 200MHz Scope
4+16Ch with Logic Analyser
AGI,MSOX3024A (1340) AU
Mixed signal oscilloscope. 4 analogue and 16
digital channels 200MHz bandwidth, 4Gsa/s,
2Mpts memory, 1M/s waveform update rate. Search and navigate capability.
Integrated time-aligned digital and analog signal viewing. USB storage, LAN
operability.
Agilent MSO6104A 1GHz Digital Oscilloscope
with Logic
AGI,MSO6104A (1320) AU
1GHz 4 + 16 channel mixed signal oscilloscope
(MSO). 4Gsa/s. XGA Colour display updates
100,000 waveforms/s with 256 levels intensity.
4 analogue channels & 16 logic channels. Deep memory. 8 digit frequency
counter function. Triggering includes video, HDTV, I2C, SPI, LIN, CAN, &
USB. FFT analysis included. LAN, USB, GPIB, & XGA interfaces standard.
Fluke 199C Scopemeter 200MHz
Hand-held
FLU,199C-SCOPEMETER (1360) AU
200MHz bandwidth 2 channel colour digital oscilloscope
withDMMfeature.14.4cmcolourdisplaywithpersistence
feature. 2.5GS/s real time sampling. Input sensitivity
5mV/div to 100V/div. Glitch capture 3ns using pulse
width triggering. Timebase range in scope mode 5ns/
div to 2min/div. Trigger types auto, free run, single shot,
edge, delay, video, video line, selectable pulse width and external. Automatic
capture and replay of last 100 screens. Measures electrical power properties
such as VA VAR, etc. Isolated inputs.
Tektronix TDS3054B 500MHz 4 Channel DSO
TEK,TDS3054 MY
Sampling rate 5GS/s. Memory length 10k. Sensitivity 1mV to 10v/div. Time
base 1ns to 10s/div. Trigger functions include video. Extensive automatic
waveform measurements. Including FFT, TV trigger, advanced analysis
(TDS3AAM), and limit testing (TDS3LIM). Battery operation.
Multimeters & ElectrometersTe
Multimeters & Electrometers cont’d.
www.techrentals.com.au
11. 99
For all your Agilent rental
equipment, contact TechRentals
12. 10
Function Generators cont’d.
Agilent/HP 33250A 80MHz Function/
Arbitrary Waveform Generator
HP,33250A (1618) AU
Frequency range 80MHz sine &
square waveforms. 50MHz pulse
waveforms with variable rise/fall times. 25MHz arbitrary waveforms, 1MHz
triangle & ramp waveforms. White noise to 50MHz. Output into 50Ω
10mVpp to 10Vpp. AM, FM, FSK, & burst modulation. Intuilink software
for programming arbitrary waveforms. HPIB & RS232C interfaces.
LCR Meters
Hioki 3532-50 5MHz LCR Meter
HIO,LCR 3532-50 (1290) AU
Frequency range 42Hz to 5MHz. 5ms high
speed measurements. Basic accuracy of
±0.08%. Memory for 30 sets of measurement
conditions, including comparator values.
Includes correlation correction function, interactive touch panel operation and
enlarged display function. Applications include laboratory use for evaluation
of operating characteristics, production line use or R&D. Measurement
data captured by a personal computer can be displayed graphically by using
standard spreadsheet software.
DC Power Supplies & Loads
Agilent/HP 6675A DC Power Supply
HP,6675A MY
102VDC, 18A, 2000W, auto-parallel up to five units, output can be
connected in series, programmable over-voltage and over-current
protection, over-temperature protection, Discrete Fault Indicator/Remote
Inhibit (DFI/RI), self-test occurs at power-on from an GPIB command, user
definable power-on state and VXI plug & play drives.
Sorensen DCS 150V, 20A
DC Power Supply
SOR,DCS150-20E (8130) AU
0-150V, 20A, 3KW. Applications
range from manufacturing test and burn-in of automotive components,
avionics electronics, telecommunications and consumer products to beam
steering, process control, laboratory R&D use. Remote control via LAN or
RS232.
Sorensen DCS60-50 60V 50A DC Power Supply
SOR,DCS60-50 (8140) AU
0 to 60V, 0 to 50A. Max power on a 240V 3ph supply 3kW, 2.5kW on a 1ph
240V supply. On 1ph 50V@50A or 60V@42A. Remote programming.
TR Built 12V Battery Supply with Cigarette Power Connector
TR,12V-BAT-CIG (8160) AU
12V 20AH battery pack with built-in charger. Has cigarette outlet and banana
plug connectors.
Trio Kenwood PD35-20 DC Power Supply
TRI,PD35-20 (8150) AU
Output 0 to 35V, 0 to 20A. Constant current, constant voltage. Multiple
parallel or series operation. Remote programming of voltage or current by
external voltage or resistance.
Xantrex XFR 600-4 600V 4A
Power Supply
XAN,XFR600-4 (8120) AU
2.4kW programmable DC power supply 0~600V, 0~4A with remote analog
programming.
Digital Storage Oscilloscopes cont’d.
Tektronix THS730A 200MHz Battery DSO
TEK,THS730A MY
Dual channel battery portable 200MHz digital storage
oscilloscope with digital multimeter facilities. Maximum
sampling rate 1GS/s. Maximum input 640V rms,
maximum float 600V rms. Waveform processing
including watts calculations. Video trigger. RS232
interface.
Tektronix TPS2014 100MHz
4 Channel Powerscope
TEK,TPS2014 (1370) AU
Sampling rate 1GS/s. All 4 channels
isolated for floating measurements.
Sensitivity 2mV to 5V/div. Measurements
for current and voltage distortion and their spectral content, harmonics,
instantaneous power, power factor and switching loss. Automatic waveform
measurements. FFT, power analysis, low & high voltage power probes
(P5120). Battery operation.
Probes and Accessories
Chauvin Arnoux Current Probe E3N 0 to 100 Amp
CHA,PROBE-I (1440) AU
Current probe for oscilloscopes which uses a Hall effect cell for the
measurement of DC or AC current. Measures currents from 50mA to
100A peak. A thumbwheel can be used to reset zero for adaption to the
measurement environment. The clamp can be used with any measurement
instrument which has a BNC input and an impedance of 1MΩ, <100pF.
Fluke 80K-40 High Voltage Probe
FLU,80K-40 (1219) AU
1 to 40kVDC or peak AC, 28kVAC RMS. Input
resistance 1GΩ, division ratio 1,000:1. Note:
input impedance of DVM must be 10MΩ or
reading will be wrong.
Tektronix P6015 40kV High Voltage Probe
TEK,P6015 (1450) AU
Bandwidth 75MHz. Input rating: 40kV pulse, 20kVDC plus peak AC. Derating
with frequency applies. Input impedance 100MΩ. Attenuation x 1000.
Function Generators
See also RF Signal & Sweep Generators on page 14
Agilent/HP 33120A 15MHz Function/Arbitrary Generator
HP,33120A MY
Function/Arbitrary Waveform Generator. Frequency 15MHz sine and square
waveforms, and 100kHz triangle and ramp waveforms. Gaussian noise
to 10MHz. Output into 50ohms 50mV to 10VP-P. AM, FM, FSK and bust
modulation. HP-IB and RS-232C interfaces both standard.
Agilent/HP 33220A 20MHz Function/
Arbitrary Generator
HP,33220A (1613) AU
Frequency range 20MHz sine & square
waveforms, 200kHz pulse, triangle, ramp,
noise, & DC waveforms. Gaussian noise to 10MHz. Output into 50Ω 10mV
to10V P-P. AM, FM, FSK, & burst modulation. Includes option 001 external
timebase reference. With optional Benchlink software waveforms can be
captured & played back. HPIB, USB, & LAN interfaces.
10
Electronics www.techrentals.com.au
13. 11
Spectrum Analysers - Low Frequency
See also Spectrum Analyser - High Frequency on page 14-16
See also Noise & Sound Analysers on page 65
Agilent/HP 35670A 100kHz Spectrum
Analyser
HP,35670A (2480) AU
Quad channel 122μHz to 102.4kHz spectrum
analyser. Up to 1600 line resolution. Displays
frequency response, power spectrum, linear
spectrum, coherence, cross spectrum, power
spectral density, and time. Signal sources: Fixed & swept sine, arbitrary
waveform, random noise, chirp. Built-in disk drive. HPIB plotter interface.
Bandwidth is 102.4, 51.2 and 25.6KHz for single, dual and quad channel
measurements respectively.
TV Test Equipment
See also Network Analysers/Antenna & Cable Test on page 16
Promax HD Ranger
DVB-T-S-C TV Analyser
PRO,HD RANGER (1726) AU
TV analyser that covers DVB-T/C/S/S2 with
MPEG-2 as well as MPEG-4 video with an
ultra fast spectrum analyser. Applications
include TV installation, maintenance and
surveillance. 18 cm bright display for use in direct sun light. Constellation
diagram available for DVB-T/C/S/S2. Datalogging with the aid of an on-screen
wizard.
Promax TV Explorer Prodig-5
PRO,PRODIG-5 (1727) AU
For the installation, maintenance and surveillance
of terrestrial, satellite and cable TV systems.
Automatically provides information about the
channels available in the network and their quality.
Displays analogue and digital channel picture.
Includes a high resolution spectrum analyser
function and MPEG decoding. Foxtel approved.
Electronic Calibrators
See also Industrial Process Calibrators on page 42-45
Fluke 5500A Multi Product
Calibrator with NATA Calibration
FLU,5500A-NATA (1660) AU
FLU,5500A MY
Calibrator sources direct voltage
& current, alternating voltage and
current, with multiple waveforms and harmonics, 2 simultaneous voltage
outputs or voltage & current. Simulates power with phase control, resistance,
capacitance, thermocouples and RTDs. Selectable ranges include the
following outputs VDC from 0 to 1.02kV, VAC from 1mV to 1.02kV with output
from 10Hz to 500kHz. AC current from 0.01μA to 11A with output from 10Hz
to 10kHz. DC current from 0 to 11A. Resistance values from short circuit
to 330MΩ. Capacitance values from 330pF to 1,100μF. Temperature t/c B,
C, E, J, K, L, N, R, S, T, U, RTD Pt385 100Ω, Pt3926 100Ω, Pt3916 100Ω,
Pt385 200Ω, Pt385 500Ω, Pt385 1kΩ, Ni120 120Ω & Cu427 10Ω.
Genrad 1433B 1.1MΩ 6 Decade Resistance
GR,1433B-NATA (1670) AU
Six decades by 1Ω to 1.1MΩ. Accuracy 0.01%. NATA calibrated.
Electronic Calibrators cont’d.
Genrad 1433F 111KΩ 7 Decade Resistance Box
GR,1433F-NATA (1680) AU
Seven decades by 0.01Ω to 111k. Accuracy 0.01% +0.002Ω. Useful for
platinum resistance thermometer calibration. NATA calibrated.
Genrad 1433-20 11.1111kΩ
6 Decade Resistor
GR,1433-20 MY
Six decades by 0.01Ω per step to
11.1111kΩ. High accuracy 0.01% up to 10MΩ steps. Low temperature
coefficient, 5ppm/˚C. Good frequency characteristics, excellent stability
(10ppm/yr, 25ppm/3yrs), low zero resistance (1MΩ per decade). May be used
for RTD stimulation. Rack mount option.
Gauss/Tesla Meters
FW Bell Gauss/Tesla Meter
BEL,4190 (1969) AU
Handheld digital ELF gauss meter. Maintains
accuracy regardless of orientation. Applications
include detecting magnetic field emissions from
overhead AC power lines, video display terminals,
office equipment and household appliances.
Analogue o/p, data logging, auto range 0.1 to 1999
mG, minimum resolution 0.1mG/.01 uT.
FW Bell 5180 Gauss/Tesla Meter
BEL,5180 (1960) AU
Magnetic measuring equipment, portable gaussmeter.
Functions include Auto Zero, Min/Max/Peak Hold,
Auto Range and Relative Mode. Displays in Gauss,
Tesla or Ampere/Meter. With Hall effect transverse
probe. Bandwidth DC to 30kHz, ranges 300G to 30kG,
resolution 0.1G. Analogue output (±3V FS) and USB
interface. Battery operated.
E & H Field Strength Meters
See also Radiation Montioring & Protection on page 66
Holaday HI-3604 E & H Survey Meter ELF
HOL,HI-3604 (1945) AU
Low frequency field meter. Designed to evaluate electric and magnetic
fields associated with 50Hz power lines. Frequency range 30 to 2,000Hz.
Measures magnetic fields from 0.1 milligauss to 20 gauss. Measures
electric fields from 1 volt/meter to 200 kilovolts/meter. LCD display. 127
reading data memory.
Holaday HI-3627 Magnetic Field Meter
HOL,HI-3627 (1980) AU
Three orthogonal field sensors. Dynamic
range 0.2mG to 20G. True RMS detection.
Frequency range 5Hz to 2kHz with an in-built
30Hz high pass filter. Meets requirements of
the Swedish protocol and the IEEE P-1140
protocol.
www.techrentals.com.au Electronics
14. 12
EMC & Power Disturbance
Simulators
Laplace SA1000 EMC Test System
LAP,SA1000 (8370) AU
Comprises PC controlled spectrum analyser 10kHz to 1.1GHz,
SA1020 pre-amplifier, RF200 broadband antenna 30MHz to 1GHz,
TTI LISN1600 LISN, and RF100 E-field & H-field probes. Supplied
with notebook PC and EMC software. EMC compliance test system.
Schaffner 438 30kV Static Discharge Generator
SFN,438 (8375) AU
Generates an electrostatic charge in a range
from 2 to 30kV. This instrument is in a ‘gun’ form.
Has a removable discharge network which can
be interchanged with other (optional) impedance
networks. Performs test to IEC61000-4-2 (AKA, IEC
1000-4-2) standards.
Schaffner Modula-6100
Immunity Test System
SFN,MODULA 6100 (8380) AU
Multifunction generator to simulate
electro-magnetic field interference effects
for immunity testing in conformity with
international, national and in house standards including the new IEC/EN
standards. Generates Interference pulses such as burst and surge and
power quality simulations.
E & H Field Strength Meters cont’d.
Narda NBM-520 ‘E’ Field Strength Meter
and Probe EF1891
NAR,NBM-520 (1925) AU
Field strength meter with EF1891 ‘E’ field probe. Detects
electric fields from 3 MHz to 18 GHz, covering fields generated
by broadcasting, telecoms, radar and any other transmission
sources within this range. Dynamic range from 0.6V/m to
1,000V/m. Applications include measuring field strengths to
comply with general safety regulations and actual radiated
power. Includes fibre optic cable with optical to electrical
converts for remote monitoring.
Narda NBM-550 ‘E’ Field Strength Meter
and Probe EF1891
NAR,NBM-550 (1930) AU
Field strength meter with EF1891 ‘E’ field probe. Detects
electric fields from 3 MHz to 18GHz, covering fields
generated by broadcasting, telecoms, radar and any
other transmission sources within this range. Dynamic
range from 0.6V/m to 1,000V/m. Includes GPS, data
logging, voice recording annotation and fibre optic cable
with optical to electrical converts for remote monitoring.
Electronics www.techrentals.com.au
TRAINING FROM TECHRENTALS
TechRentals, with the support of many manufacturers including Anritsu, Fluke, Agilent, Megger and
Omicron, are able to provide tailored training suited for the electrical, networking, instrumentation and
construction industries.
These partnerships allow TechRentals to work together to offer many types of training from online
modules, to partner standard training. Your training requirements can be fully customised, whether it
be high-end electrical, telecommunications, fibre optics or NDT testing.
When you rent you have access to:
• Specific asset training as part of the set up and download service
• Online training videos via our website to assist in operation of certain equipment
Periodically, TechRentals offer a number of short courses designed to enhance skills and experience
in areas of particular benefit to technical personnel. Notices of these courses are sent by email
requesting an expression of interest and take place throughout Australia. If you would like to receive
these notifications please email training@techrentals.com.au.
The TechRentals Wiki is well worth a visit, as this resource centre provides manuals, technical
information and how-to videos. Visit www.techrentals.com.au and select Technical Tips and Videos.
Don’t forget to visit the TechRentals YouTube site with over 100 videos containing training, practical
demonstrations and much more. (http://www.youtube.com/techrentals)
15. 13
Specialists in supplying IT hardware, project management, audio
visual turn key solutions and facilitating short and long term projects on
everything IT and AV, TR Vidcom delivers unparalleled levels of service
and a comprehensive range of leading-edge products at competitive rates.
Our product range includes:
Our vision at TR Vidcom is to respond to clients’ needs by combining
technology, equipment and technical expertise.
Get access to our large inventory of leading brands
including HP, Apple, Lenovo, Dell, Samsung, Toshiba,
Orion, LG and more...
Take advantage of our customised solutions and rental
periods, and the flexibility to update at any time. Our top
technical advice and support is only one phone call away!
VC0294
1800 843 266
www.trvidcom.com.au
rent@trvidcom.com.au
vidcom
Originally established in 1983 as the
Computer Division of TechRentals, TR Vidcom
is Australia’s most vibrant company
in the exciting IT and Audio Visual industry.
• Notebooks and Desktops
• LCD and Plasma Screens
• Printers and Plotters
• Multi Panel Plasma Displays
• Projectors and Screens
• Apple Products
• Servers and Networking
• Video and Teleconferencing
• Stocktake Equipment
• Rich Media Streaming
16. 14
RF Signal & Sweep Generators
Frequency Counters
Spectrum Analysers - High Frequency
Network Analysers/Antenna & Cable Test
Communication Test Sets
Distortion Analysers
Power Meters - RF
RF Amplifiers
RF Attenuators
Antennas
RF Accessories
See also Function Generators on page 10
Agilent/HP 8648D-1E5 4GHz Signal
Generator
HP,8648D (2330) AU
HP,8648D-1E5 MY
Signal generator 9kHz to 4GHz with AM/
FM/Phase modulation output range from
+10 to -136dBm with ±1dB accuracy up to 2.5GHz. 0.001Hz resolution.
Complete with option 1E5 high stability timebase (<±0.1ppm/yr).
Agilent/HP E4433B ESG-D4000A
4GHz RF Digital Signal Generator
HP,ESG-D4000A (2335) AU
Signal generator with digital modulation
facilities. Frequency range 250kHz
to 4GHz, resolution 0.01Hz. AM, FM,
phase, and pulse modulation. Wideband AM modulation. Internal modulation
and pulse generator to 50kHz. Step sweep of frequency and power. Option
1E5 high stability reference 0.1 ppm/yr included.
Frequency Counters
See also Electronics on page 8
Agilent/HP 53181A 3GHz Frequency Counter
HP,53181A (3112) AU/MY
Option 010 high stability timebase included.
HPIB interface. PC based Benchlink meter
software available.
Agilent/HP 5350B 20GHz Frequency Counter
HP,5350B MY
Microwave frequency counter. 10Hz to 20GHz. HPIB interface.
Spectrum Analysers - High Frequency
Advantest 31.8GHz Portable
Spectrum Analyser
ADV,U3771 (2540) AU/MY
Portable 9kHz to 31.8GHz spectrum
analyser. 3 way power. Battery, 240V &
DC. RBW 100Hz to 3MHz, sensitivity
-117dBm@34GHz (typ). High-stability reference. Includes a wide variety of data
analysis functions & zoom function. With signals applied to both Input 1 and
Input 2, two signals such as an IF signal and a carrier can be measured.
Support for USB for printer and memory. Storage image formats: PNG, BMP,
configuration file BIN, XML.
Agilent N9340A 3GHz Spectrum Analyser
with Tracking Generator
AGI,N9340A (2565) AU
Portable handheld spectrum analyser with a frequency range from 100kHz
to 3GHz. Resolution bandwidth 30Hz to 1MHz. Includes tracking generator.
DANL -126dBm (typical). Sweep time 10ms. USB connectivity allows for PC
control and data transfer.
Agilent N9344C 20GHz
Spectrum Analyser with
Tracking Generator
AGI,N9344C (2538) AU
AGI,N9344C-TG MY
Spectrum analyser 9kHz to 20GHz with
5MHz to 7GHz tracking generator. -144dBm displayed average noise level
(DANL), <0.95s sweep time for 20GHz full span. Average continuous power,
+30dBm for 3 minutes maximum. Flexible remote control via USB/LAN. User
memory 64MB, able to store approximately 14,000 traces.
Airmagnet Wi-Fi Spectrum Analyser
AIR,AIRMAG SPEC AN (2580) AU
Laptopbasedspectrumanalyser. Specificallyidentifysourcesofinterference
in Wi-Fi bands 2.4-2.5GHz (802.11 b/g) and 4.9-5.9GHz (802.11a), and
track them to their physical source. Automatic and real time identification
of Bluetooth, cordless phones, microwaves, analogue video cameras, RF
jammers and more. Immediately “see” and name each device.
Anritsu MS2711A 3GHz
Portable Spectrum Analyser
ANR,MS2711A MY
Portable spectrum analyser, 9kHz to 3GHz.
Light weight battery powered spectrum
analyser with LCD. Resolution bandwidth
down to 10kHz. Suitable for cellular telephone
walk or drive tests to determine coverage and base station positioning. Can also
be used for VHF/UHF signal surveying. N type connector.
Anritsu MS2712E 4GHz
Spectrum Analyser/Tracking
Generator
ANR,MS2712E (2560) AU
Portable handheld spectrum analyser 9kHz
to 4GHz, DANL -162dBm in 1Hz RBW, RBW
1Hz to 3MHz. Tracking generator -50dBm to
0dBm in 0.1dB steps. Applications include, spectrum monitoring, broadcast
proofing, RF and microwave measurements, Wi-Fi and wireless network
measurements. Store up 2,000 traces and setups on board or on USB flash
drive. One-button envelope creation, Trace Save-on-Event feature.
RF Signal & Sweep Generators
Radio Frequency www.techrentals.com.au
Stay informed on T&M news,
application notes and case studies
with @TechRentals on Twitter
18. 16
Spectrum Analysers - High Frequency
cont’d.
Anritsu MS2721A 7.1 GHz
Spectrum Analyser
ANR,MS2721A (2550) AU
100kHz to 7.1GHz. For deploying, maintaining
and troubleshooting wireless base stations
and Wi-Fi (802.11a, b and g) systems,
and general spectrum analysis. Smart
measurements include channel power, adjacent channel power ratio, carrier to
interference ratio and field strength. AM/FM/SSB demodulator included and
internal speaker for monitoring. DANL -153 dBm at 1GHz. Phase noise -100dBc/
Hz at 10KHz. Store unlimited traces and setups. Remote programming via
Ethernet port.
Rohde & Schwarz FSH3 3GHz Spectrum Analyser/
Tracking Generator/Vector Measurement
RS,FSH3-TG-V (2575) AU
RS,FSH3-TG MY
Handheld portable battery operated spectrum analyser
100kHz to 3GHz. Resolution bandwidth 1kHz to 1MHz.
Less than -105dBm noise level (-114dBm typical).
Suitable for RF surveying applications. Includes vector
transmission and tracking generator options.
Network Analysers/Antenna
& Cable Test
Anritsu S331D 4GHz Colour
Sitemaster Antenna
ANR,S331D (2185) AU/MY
Antenna and cable test set. Frequency range
25MHz to 4GHz. Measures return loss, SWR,
cable loss, and distance to fault. Return loss
range 0 to 60dB. SWR range 1 to 65. Distance
to fault range 1,197m. Insertion loss range -120 to +100dB. Cable loss range
(oneport)0to30dB. N(f)Typeport. Analysissoftwarediscsincludedcontaining
distance to fault and Smith chart tools. Complete with calibration standard,
AC/DC adaptor, and 12VDC car cigarette lighter adaptor.
Anritsu S331E 4GHz
Sitemaster Cable &
Antenna Tester
ANR,S331E (2180) AU/MY
Cable and antenna analyser, frequency range
2MHz to 4GHz. Measures return loss, VSWR,
cable loss, and Distance To Fault. Suitable for
legacy networks in addition to the new 3G and 4G networks being installed.
Applications include cable & antenna installation and maintenance for wireless
service providers, contractors, military, aerospace, defence, and public safety
applications.
Anritsu S332D Colour Sitemaster
Antenna Tester
ANR,S332D MY
Antenna and cable test set including
spectrum analyser. Frequency range 25 to
4,000MHz. RBW 100Hz to 1MHz. Measures
return loss, SWR, cable loss, and distance to
fault. N(f) Type port. Analysis software containing DTF and Smith chart tools
included. Complete with calibration standard, AC/DC adaptor, and 12VDC car
adaptor.
Network Analysers/Antenna
& Cable Test cont’d.
Anritsu S332E Sitemaster including
Spectrum Analyser
ANR,S332E (2175) AU
Antenna and cable analyser 2MHz to 4GHz
and spectrum analyser 100KHz to 4GHz.
DANL -152dBm. Measures return loss,
VSWR, cable loss, and distance to fault.
N(f) Type port. Analysis software containing
DTF and Smith chart tools included. Complete with calibration standard,
AC/DC adaptor, and 12VDC car adaptor. Cable & antenna installation and
maintenance for wireless service providers, contractors, military, aerospace
and defence, and public safety applications.
Anritsu S332E Sitemaster Including
Spectrum Analyser and Opt 431,31,509
ANR,S332E-CMPA-MOD (2165) AU
antenna and cable analyser 2MHz to 4GHz
and spectrum analyser 100KHz to 4GHz.
DANL -152dBm. Options included, indoor
outdoor Coverage Mapping, GPS Receiver
and AM/FM/PM Analyser. Measures return
loss, VSWR, cable loss, and distance to fault. Analysis software containing
DTF and Smith chart tools included. Cable, antenna, installation and
maintenance spectrum analysis, coverage mapping and AM/FM/PM demod
for wireless service providers, contractors, military, aerospace and defence,
and public safety applications.
Anritsu S820D Microwave Sitemaster
25MHz to 20GHz
ANR,S820D (2150) AU/MY
Microwave antenna and cable test set.
Portable single port analyser, providing
return loss (SWR) insertion loss and distance
to fault measurements in the frequency
range of 25MHz to 20GHz. Unit comes standard with RS232 interface, Smith
chart and software management tools, AC/DC and automotive adaptor. A
comprehensive range of precision waveguide components and adaptors are
available.
Anritsu Sitemaster Waveguide Components
ANR,WAVEGUIDE-ADAP (2190) AU/MY
Calibration components and wave guide to co-ax adaptors for Anritsu S820x
Sitemaster. Set includes 1/8 and 3/8 shorts, termination, and waveguide to
co-ax adaptor.
Agilent/HP 8753D 6 GHz Vector Network Analyser
HP,8753D (2745) AU
Two port vector network analyser with integral S-parameter test set. Frequency
range 30 kHz to 6 GHz with included option 006. In-built 1Hz resolution
synthesized signal source. Calibration kit included.
Communication Test Sets
Aeroflex IFR 2945B Communications
Service Monitor
IFR,2945B (2368) AU
Communications Service Monitor is ideally
suited to the testing of two way radios and
trunking repeaters allowing verification of performance, and rapid diagnosis of
faults. Includes a combination of test instruments such as a full performance
spectrum analyser, oscilloscope and tracking generator. Frequency range
400kHz to 1.05GHz.
Radio Frequency www.techrentals.com.au
19. 17
BR0256
Get your FREE Sepura TETRA
two way radio demo!
To book your free demonstration, call our friendly team today
on 1800 222 327, or email us at rent@trhirecom.com.au
Melbourne | Sydney | Newcastle | Brisbane | Townsville | Adelaide | Darwin | Perth
TR Hirecom is offering FREE demonstrations
of the Sepura range of TETRA radios from our diverse fleet.
Your free demo will include:
Comprehensive Site Test
Demonstration of TETRA Repeaters
and TETRA Radios
Educational TETRA White Paper
A clear understanding of what a TETRA System
can achieve for your organisation
Sepura STP9000 TETRA Digital
Hand Held Portable Two Way Radio
• Large colour screen
• 1.8 W RF power
• Full keypad
• Dustproof, waterproof
and submersible IP67 rating
• Integrated Bluetooth option
• GPS capability
• Robust and secure
• Integrated RFID tag
Sepura STP9200 TETRA Digital
Hand Held Portable Two Way Radio
• 1.8 W RF power
• Monochrome screen
• Enhanced and intuitive user interface
• Dustproof, waterproof and submersible
IP67 rating
• Integrated RFID tag
• GPS capability
Sepura STP9100 TETRA Digital
Hand Portable Two Way Radio
• 1.8 W RF power
• Large colour screen
• Dustproof, waterproof and submersible
IP67 rating
• Integrated Bluetooth option
• GPS capability
• Robust and secure
• Integrated RFID tag
Sepura STP8X IS TETRA Digital
Hand Held Portable Two Way Radio
• Full, tactile keypad
• IP67 Rating
• V6 IECEx/ATEX approval
• Loud and clear audio
• Man down alarm
• GPS option
• Bluetooth connectivity
• Intrinsically Safe
• MicroSD card slot
hirecom
Call to arrange your
FREE demo 1800 222 327
20. 18
Power Meters - RF cont’d.
Marconi 6970 Digital Power Meter
MAR,6970 MY
NiCd battery operated with digital display. Complete with AC adaptor. Requires
sensor. Sensors available for 10MHz to 26.5GHz frequency range.
Marconi 6910 Power Sensor
MAR,6910 MY
Frequency range 10MHz to 20GHz. Power range -30dBm to 20dBm (1μW to
100mW). Max RF i/p 25dBm (300mW) CW 42dBm (15W) peak for 2μs. Sensing
element semiconductor thermocouple. VSWR 1.25: 10MHz to 30MHz, 1.1:
30MHz to 2GHz, 1.18: 2 to 16GHz, 1.28: 16 to 18GHz, 1.4: typical 18 to 20GHz.
Linearity factor provided with sensor. Accuracy ±0.5% at 25˚C between 10
& 20dBm. Improves by a factor of 10 for each lower range. Calibration factor
provided with sensor. Accuracy uncertainty provided with sensor. Resolution
0.01%. RF connector precision N-type (M) 50Ω.
Marconi 6912 Power Sensor
MAR,6912 MY
Frequency range 30kHz to 4.2GHz. Power range 30dBm (1μW) to 20dBm
(100mW).
Marconi 6913 Power Sensor
MAR,6913 MY
Frequency range 10MHz to 26.5GHz. Power range 30dBm (1μW) to 20dBm
(100mW). Max 25dBm (300mW) CW, 42dBm (15W) peak for 2μs. Sensing
element semiconductor thermocouple. VSWR 1.40: 10MHz to 50MHz, 1.15:
50MHz to 100MHz, 1.10: 100MHz to 2GHz, 1.15: 2 to 12.4GHz, 1.20: 12.4 to
18GHz, 1.25: 18 to 26.5GHz. Calibration factor provided at 1GHz intervals
(500MHz intervals above 20GHz) with each sensor. Accuracy uncertainty
provided with each sensor. Resolution 0.01%. Linearity factor accuracy ±0.5%
at 100mW, decreasing by 0.005% per 1mW.
Marconi 6920 Power Sensor
MAR,6920 MY
High sensitivity diode sensor. Frequency range 10MHz to 20GHz. Power
range -70dBm (0.1nW) to -20dBm (10μW), max 26dBm (400mW) CW
+30dBm (1W) peak for 2μs. Sensing element Shottky barrier diode. VSWR
1.4 to 1.2:10 to 40MHz, 1.20:40MHz to 10GHz, 1.35:10 to 18GHz, 1.40
typical 18 to 20GHz. Calibration factor provided at 1GHz intervals with each
sensor. Accuracy uncertainty provided with each sensor.
Marconi 6923 RF Power Sensor
MAR,6923 MY
High sensitivity diode sensor. Frequency range 10MHz to 26.5GHz. Power
range -65dBm (0.3nW) to -20dBm(10μW), max 26dBm (400mW) CW,
+30dBm (1W) peak for 2μs. Sensing element Shottky barrier diode. VSWR
1.4 10 to 40MHz, 1.15 40 to 100MHz, 1.12 0.1MHz, 1.17 2 to 8GHz, 1.30 8
to 18GHz, 1.50 typical 18 to 26.5GHz. Calibration factor provided at 1GHz
intervals with each sensor. Accuracy uncertainty provided with each sensor.
Resolution 0.01%. Linearity factor provided with each sensor. Accuracy
±1% between -30 to -20dBm. RF connector type N (M) precision 50Ω.
Rohde & Schwarz NRT Power Reflection Meter
RS,NRT (2140) AU
Measures directional power forward and reverse under operational
conditions. NRT-Z44 sensor included, range 3 mW to 120 W, 200 MHz to
4 GHz. Measurement method is compatible with all common analog and in
particular digital modulation standards. GSM/EDGE, 3GPP (W-/TD-CDMA),
CDMA (IS-95), CDMA2000, PHS, NADC, PDC, TETRA, DECT, DAB,
DVB-T and many more.
Communication Test Sets cont’d.
Aeroflex IFR 3500A Radio Communications Test Set
IFR,3500A (2360) AU
Communications service monitor. Portable radio test set
for AM, FM, P25, DMR and NXDN radio transceivers,
antenna and cable testing in vehicle, at remote locations
or on bench testing. Frequency range 2M to 1GHz. 20W
power handling without external attenuator. Includes
spectrum analyser, oscilloscope, tracking generator and
75W 6dB attenuator.
Distortion Analysers
Agilent/HP 8903B Audio Analyser
HP,8903B (3020) AU
Audio analyser for communications and other applications. Measures
distortion, sinad, signal-to-noise, ACV, DCV, frequency. Low distortion
programmable sine wave source. Frequency range 20Hz to 100kHz. Optional
400Hz high pass and CCITT weighting filters fitted.
Power Meters - RF
Agilent/HP E4418B E Series Power Meter
HP,E4418B-001 (2120) AU
100μW to 25W (-70dBm to 44dBm), 9 kHz to
110 GHz (power sensor dependent ), 4 digit
display - watts, dBm, dB (rel). Battery or mains
powered. Power sensor required, select and
specify when ordering.
Agilent/HP E9300A Power Sensor 1μW to 100mW, 10MHz to 18GHz
HP,E9300A (2125) AU
Power sensor for HP EPM series power meters. E-series average power
sensor. 10MHz to 8GHz, 1μW to 100mW (-60dBm to 20dBm).
Agilent/HP E9300B Power Sensor 1μW to
25W, 10MHz to 8GHz
HP,E9300B (2135) AU
Power sensor for HP EPM series power meters.
E-series average power sensor. 10MHz to
18GHz, 1μW to 25W (-30dBm to 44dBm).
Anritsu MA24104A Inline Power Sensor
0.6 to 4GHz, 2mW to 150W
ANR,MA24104A (2115) AU
A dual path architecture that enables true RMS
measurements over the entire frequency and dynamic
range allowing users to measure CW, multi-tone and
digitally modulated signals such as GSM/EDGE, CDMA/
EV-DO,WCDMA/HSDPA, WiMAX, and TD-SCDMA.
Can be connected directly to a laptop or Site Master with
option 19.
Bird 43 Power Meter
BIR,43 MY
RF thruline power meter. Requires Bird element of specified frequency and
power. Measures forward and reflected power by reversing the element.
Bird RF Element
BIR,ELEMENT-LF MY
BIR,ELEMENT-HF MY
RF elements for Bird watt meters. Available in various power and frequency
ranges.
Radio Frequency www.techrentals.com.au
21. 19
RF Amplifiers
ENI 604L 4W Wideband 1GHz RF Amplifier
ENI,604L (2803) AU
Linear wideband RF power amplifier. 4W output at an input of 0.13mW from
0.5 to 1GHz. Saturated output 7W 0dBm input. Extended performance
gives saturated output to a max of 16W at 10MHz and 12W at 100MHz
typically.
Agilent/HP HP8449B Preamplifier 1GHz to 26.5GHz
HP,8449B MY
High-gain (+30dB gain), low-noise preamplifier. Frequency range of 1 to
26.5GHz. Increases sensitivity of any microwave spectrum analyser for
detection and analysis of very low-level signals. Improved sensitivity can
reduce measurement time.
RF Attenuators
Agilent/HP 8494B/8495B Attenuator Set 81dB, 1 & 10dB steps 18GHz
HP,8494B-8495B (2904) AU/MY
Coaxial step attenuator set. DC to 18GHz. 0-11dB in 1dB steps and 10-70dB in
10dB steps. Type N(f) connectors. Comprises a connected set of types 8494B
and 8495B with 11716A rigid interconnect kit.
Agilent/HP 8495B 70dB x 10dB Coaxial Step Attenuator
HP,8495B (2902) AU
DC to 18GHz. 0 to 70dB in 10dB steps.
Agilent/HP 8494/5B Coaxial Step Attenuator Set 81dB x 1dB
HP,8494/5B MY
DC to 18GHz. 0 to 11dB in 1dB steps. 11 to 81dB in 10dB steps. Comprises a
connected set of types 8494B & 8495B. Type N(f) connectors.
Agilent/HP 8495D 70dB 26.5GHz Step Attenuator
HP,8495D (2905) MY
Frequency range DC to 26.5GHz. 70dB step attenuator in 10dB steps. Max
continuous power 1W. 3.5mm connectors.
Anritsu Attenuator 50W 30dB DC to 18GHz
ANR,50-30-18 (2903) AU
30dB, 18GHz, 50W. N Type connectors.
Weinschell 33-10-34 25W 10dB 8.5GHz RF Attenuator
WEI,33-10-34 (2919) AU
DC to 8GHz, 10dB, 25W. Type N connectors.
Weinschell 34-30-34 25W 30dB 4GHz RF Attenuator
WEI,34-30-34 (2922) AU
DC to 4GHz, 30dB, 25W. Type N connectors.
Antennas
Advantest TR1720 100kHz to 30MHz Antenna
ADV,TR1720 (1847) AU
Loop and vertical antenna system. Frequency range 100kHz to 30MHz.
Suitable for use with ADV,R4131D for field strength and EMI measurements.
An antenna tuner is included which can be used as an input/output filter to
reject noise below the measuring frequency.
AH Systems 300MHz to 12GHz Antenna System
AH,ANTENNA (1834) AU
Log periodic antenna system. Comprises two antennas: A: 300MHz to
1.8GHz, power handling 1kW, antenna factor 15 - 32dB, B: 1 to 12GHz, power
handling 10 W, antenna factor 25 - 44dB. Complete with tripod.
Antennas cont’d.
AH Systems SAS-200/550-2B 100Hz to 60Mhz Rod Antenna
AH,SAS-200/550 (1837) AU
Monopole rod antenna. Frequency range 100Hz to 60MHz. Active unit with
battery power. Rod height 220mm to 1.09m. Ground plane 450 x 450mm.
Antenna factor 0 to 24.
AH Systems SAS-200/571 Antenna
AH,SAS-200/571 (1840) AU
AH,SAS-571 MY
Double ridge guide horn antenna. Frequency range 700MHz to 18GHz.
Continuous power 300W. Impedance 50Ω 200V/m max radiated field. Type
N(f) connector.
Anritsu Dipole Antenna Kit
ANR,ANTENNA (1834) AU
MP534A dipole antenna 25 to 520MHz and MP651A 470 to 1700MHz.
Directional Yagi Antenna
ANT,DIRECTIONAL YAGI (1829) AU
Various directional Yagi antennas. Frequency rangers from 824 M (UHF) to
2.17 GHz (UHF).
Omnidirectional Antenna
ANT,OMNIDIRECTIONAL (1826) AU
Various omnidirectional antenna types such as telescopic whip, folded dipole
and monopole. Frequency ranges from 70MHz to 2.17GHz.
COM Power Double Ridged Horn Antenna 1 to 18GHz
COM,AH-118 MY
Frequency range 1 to 18GHz, VSWR 2.0:1, Polarization: Linear, Output
Impedance: 50Ω, connector types Antenna output: N (f).
RF Accessories
RF Connector Kit N, BNC, TNC, SMA, APC7
TR,RF-CONN (2816) AU
RF connection adaptors. Comprises couplers with interchangeable
connectors; DIN 7/16, N Type, BNC, SMA, TNC, APC-7 and UHF
Huber & Suhner Sucoflex 104PE 26.5GHz RF Cable
SUH,SUCOFLEX-104PE MY
Fexible high performance microwave cable with frequency range up to
26.5GHz. Length 1.0 meter and comes with 3.5mm connectors.
www.techrentals.com.au Radio Frequency
Our rental with purchase option scheme is
available to approved business customers.
Generally the rates quoted on the rental purchase
option are based on a 12 month rental period
after which you may purchase the equipment by
paying an amount equal to month’s rental.
However these plans can be tailored to suit your
particular timeframe requirements.
If you have any questions about this scheme or
the type of equipment that would apply please
call our technical representatives to discuss your
requirements.
22. 20
LAN Cable Testers
LAN/WAN Analysers
PDH/SDH Analysers
DSL/POTS Test Set
Light Sources & Power Meters
Fusion Splicers
OTDR & Fibre Inspection
Fibre Optic Launch Cables & Patch Leads
Fluke DSX-5000 Cable
Analyser 1 GHz Class FA
FLU,DSX-5000 (3278) AU
1GHz cable analyser copper test solution enables
testing and certification of twisted pair cabling for up
to 10 GigE deployments and will certify shielded and
unshielded structured cabling systems Cat 3, 4, 5, 5e, 6, 6A, Class C, D, E,
EA, F, and FA at Level V accuracy. 9 second Cat 6 autotest. Built in Alien
Crosstalk testing capability. LinkWare PC reporting software included.
Fluke DTX1800 Cable Analyser
900MHz Cat 7
FLU,DTX1800 (3260) AU/MY
Category 7 cable certification tester up to 900MHz.
TeststoCategory3,4,5,5E,6,6aand7.Cableanalyser
for use with shielded and unshielded twisted pair Cat 6
Autotesttimeof12seconds.LinkwarePCsoftware,and
USB cable included. Internal memory stores results.
Optional multimode & single mode OTDR module.
Fluke DTX-MFM2 Multimode Fibre
Adaptor for DTX Cable Analyser
FLU,DTX-MFM2 (3270) AU/MY
DTX1200/1800 multimode fibre interface. Tests
fibre installations in local area networks. Fits in the
slot on the back of DTX cable analyser (standard
copper cable adaptors can be connected but not used simultaneously).
Provides fibre testing and certification. Bi-directional testing at 850nm
& 1300nm at the same time. Measures optical power loss, length, and
propagation delay for multimode fibres. Pass/fail results based on common
fibre standards. Includes in built visual fault locator. (VFL).
Fluke DTX Compact OTDR SM-MM
FLU,DTX-OTDR (3280) AU
Full featured multimode & single mode OTDR module
that snaps onto a DTX Cable Analyser. Shoots and analyses
traces on single mode 9nm and multimode 62.5 & 50nm fibre.
Fluke DTX Permanent Link Adaptor Analyser
FLU,DTX-PLA (3295) AU
Fluke PLA001 Permanent Link Adaptor.
Fluke DTX Fibre for DTX Cable Analyser
FLU,DTX-SFM MY
DTX1200/1800 singlemode fibre interface. Tests fibre installations in local
area networks. Fits in the slot on the back of DTX cable analyser (standard
copper cable adaptors can be connected but not used simultaneously).
Provides fibre testing and certification. Bi-directional testing at 1310nm
& 1550nm at the same time. Measures optical power loss, length, and
propagation delay for singlemode fibres. Pass/fail results based on
common fibre standards. SC optical connectors. Includes in built visual
fault locator (VFL).
LAN Cable Testers cont’d.
Fluke DTX-SFM2 Single
Mode Fibre Adaptor for
DTX Cable Analyser
FLU,DTX-SFM2 (3265) AU/MY
DTX1200/1800 single mode fibre interface.
Use for testing fibre installations in local area networks. Fits in the slot
on the back of DTX cable analyser (standard copper cable adaptors can
be connected but not used simultaneously). Provides fibre testing and
certification. Bi-directional testing at 1310nm and 1550nm at the same
time. Measures optical power loss, length, and propagation delay for single
mode fibres. Pass/fail results based on common fibre standards. SC optical
connectors. Includes in built visual fault locator. (VFL)
LAN/WAN Analysers
EXFO AXS-200-850 Ethernet Test Set
EXF,AXS-200_850 (3228) AU
Two AXS-200/850(s) for installing, tuning up or maintaining
Ethernet and IP services up to 1Gbit. Bidirectional RFC
2544 testing. Applications include performance assessment
of Carrier Ethernet services, activation and maintenance
of metro Ethernet networks, deployment of active Ethernet
(point-to-point) access services, traffic generation and
monitoring for network performance testing Bit-error-rate testing (BERT)
up to layer 4. Pass/fail results with user-defined thresholds. QoS, ToS and
diffserv capabilities. Copper and SM & MM fibre interface supplied.
EXFO ETS-1000L 10/100/1000 Ethernet Loopback
EXFO,ETS-1000L MY
Ethernet/Gigabit ethernet loopback unit ETS-1000L is intended for performing
loopback at the physical, data link, network and transport layers of the OSI
model. It allows carrying out loopback control via OAM protocol and remote
control via TELNET protocol.
EXFO FTB-860G NetBlazer
10G Ethernet Tester
EXF,FTB-860G (3223) AU
Performs 10 Gbps RFC 2544 measurements
and EtherSAM (ITU-T Y.156sam), for turnkey
deployment, validation, and troubleshooting of
access and metro ethernet services. IPv6 testing capabilities BERT, RFC,
traffic gen and through mode. NetBlazer offers GUI navigation, dedicated
quick-action buttons, and clear notifications for accurate interpretation of
test results.
Fluke Networks Etherscope II Gigabit LAN
Analyser
FLU,ETHERSCOPE-EX (3226) AU
10M/100M/1Gigabit Copper, Fibre and WLAN a/b/g
network analyser. Discover network elements
and fault location even in a switched environment.
IP analysis of Carrier Ethernet services. VLAN
discovery, connected host details and trending data. Document and report
network performance. View detailed information about RF signal strength, APs,
SSID, channel information and more. Cable ID accessory for tracking cable
routes included.
Fluke Optiview Pro Gigabit 10/100/Gigabit LAN
Analyser
FLU,OPTIVIEW-GIG (3227) AU
Provides network analysis on 10/100/Gigabit ethernet
networks (multimode fibre & copper). Features active
discovery in switched networks, full 7 layer analysis,
ITO (Internetwork Throughput Option), trace switch
route, free string match, reporting and documenting, address-to-name
mapping, packet capture and decode, SNMP device analysis, RMON II traffic
analysis, application level traffic analysis and much more.
LAN Cable Testers
Data & Telecommunications www.techrentals.com.au
23. 7” 12 HOURS
1sec 2Gb
iOLMReady:Turn
complexOTDRanalysis
intoaone-touchtask
Outdoor-enhanced
touchscreen
Intuitive,
Windows-like GUI
Improved navigation
and performance
Rugged enough
for any OSP
environment
Never-let-you-
downbatterylife
Ready to test
in 1 second
Storeupto
20000traces
(bellcore)
COMPACT.
POWERFUL.
INTUITIVE.
Introducing Uncompromising
Tablet-Inspired Handheld OTDRs,
the MAX-700B series.
Three models to cover the most common fiber test applications
www.EXFO.com/MaxOTDR
› MAX-715B Last-Mile OTDR › MAX-720B Access OTDR › MAX-730B FTTH/PON OTDR
LAN/WAN Analysers cont’d.
JDSU SmartClass 10M-1G Ethernet Tester
JDSU,CSC-ETHTR-PC (3249) AU
SmartClass Ethernet for comprehensive installation, turn up and maintenance
of Ethernet IP services up to 1 Gbit. Performs Bidirectional RFC 2544,
Asymmetric RFC and multiple streams testing. Applications include
performance assessment of Carrier Ethernet services, activation and
maintenance of metro Ethernet networks, deployment of active Ethernet
(point-to-point) access services, traffic generation and QoS verification.
JDSU SmartClassEthernet 10M-1G Ethernet Tester
JDSU,SMARTCLASS-ETH (3220) AU
Two SmartClass Ethernet(s) provided for comprehensive installation, turn up
and maintenance of Ethernet IP services up to 1 Gbit. Performs Bidirectional
RFC 2544, Asymmetric RFC and multiple streams testing. Applications
include performance assessment of Carrier Ethernet services, activation
and maintenance of metro Ethernet networks, deployment of active Ethernet
(point-to-point) access services, traffic generation and QoS verification.
PDH/SDH Analysers
JDSU ANT 5 SDH/PDH Access Tester
JDSU,ANT5-STM4 (3445) AU/MY
Field tester for the installation, commissioning
and fault finding of fibre and copper SDH/PDH
networks. Electrical interfaces for PDH/SDH:
E1, E3, DS3, E4, STM-0e/1e; Optical interfaces
for SDH/SONET: STM-1/OC-3, STM-4/OC-12.
BERT, round trip delay measurement, error performance analysis: G.821,
G.826, G.828, G.829, M.2100,M.2101 and ANSI. Autoconfig functionality for
automatic traffic detection, line rate, structure and mapping. Offline Viewer
SW provides result analysis and report generation.
PDH/SDH Analysers cont’d.
JDSU ANT 5 SDH/PDH Access Tester
JDSU,ANT5-STM16 (3446) AU/MY
SField tester for the installation, commissioning and fault finding of fibre and
copper SDH/PDH networks from 1.5Mb/s to 2.5 Gb/s. Optical testing at dual
wave lengths at STM-1, STM-4, and STM-16. Electrical testing at DS1/E1/E3/
DS3/E4 and STM-1 interfaces. Full analysis of concatenated mappings. ATM
analysis for service verification of ATM and 3G/UMTS networks.
JDSU EDT-135 E1 and Data Tester
JDSU,EDT-135 (3450) AU/MY
Field service tester for commissioning,
maintenance and troubleshooting of E1
PCM2Mbps and V.11/RS-442, V.24/RS-232,
V.35,V.36/RS-449, EIA-530 data circuits
operating at 50bps to 2Mbps. Provides framed
& unframed monitoring, end-to-end testing, drop
& insert, channel associated signalling; error & alarm analysis, S bit, NFAS
& NMFAS monitoring & generation. Round trip delay measurement, G.821,
G.826 & M.2100 quality of service measurements. Signal level measurement
& primary multiplexer testing.
Acterna MTS 8000/T-BERD Transport Module
JDSU,MTS8000 MY
Multirate interface for PDH-DS1/DS3/E1/E3/E4,STS-1 OC-3/12/48/48, STM-
1e/1/4/16 and interface for OC-192 STM-64 with the ability to monitor down
to the STS-1 level inside of any supported optical rate. Used for verifying and
qualifying the performance of SDH and Gigabit ethernet, telecommunications
networks.Electricalandopticalinterfacesatrates1310/1550nm).Alsosupports
the NewGen (ethernet over Sonet/SDH) and able to perform RFC2544.
Ethernet IP testing with 10/100/100Mbps electrical RJ-45 Interfaces. Supports
VLAN, Q-in-Q,VPLS,MPLS Tunnelling application. Comes with touch screen
GUI operation. Measures optical power and frequency. Floppy drive installed.
Data & Telecommunicationswww.techrentals.com.au
24. 22
Light Sources & Power Meters cont’d.
Fluke FTK1000 Multimode Fibre
Optic Light Source & Meter
FLU,FTK1000 (3365) AU
Light source is multimode 850nm and 1300nm.
Power meter has 850/1300nm multimode and
1310/1550nm single mode. Manage results and
print reports via Power meter memory, PC and
supplied software.
Fluke FTK150 Optical Fibre
Light Source/Meter
FLU,FTK150 (3366) AU
Fibre test kit. Light source is multimode 850nm and
1300nm. Power meter has calibrated measurements at
850/1300nm multimode and 1310/1550nm single mode.
+3dBm to -55dBm measurement range with 0.01dB
resolution. Manage results and print reports via Power
meter memory, PC and supplied software. Supplied with
various connectors and patch leads.
JDSU/Acterna OLA-55 Single Mode Optical Attenuator
JDSU,OLA-55 MY
Adjustable wavelength from 1260 to 1650nm (1nm increments).
Calibrated wavelengths 1310nm, 1550nm & 1625nm. Maximum
permitted level =23dBm. Optical Interface: FC-PC.
JDSU OLP-55 Optical Power Meter
JDSU,OLP-55 MY
Optical Power Meter BN 2277/01 Power & Loss Measurement for installation,
maintenance and repair of fiber optics networks. Display Range: -70 to +20dBm,
calibrated wavelengths: 850, 1310, 1550 & 1650nm. Optical connection: FC.
JDSU OLSP-55 Optical Laser Source
JDSU,OLS-55 MY
Operates on dual wavelength of 1310nm and 1550nm. Output power is from -7
to 0 dBm. Optical Interface: FC-PC.
Kingfisher KI-28010 Single Mode APC
Light Source and KI-7600 Power Meter
KIN,KI28010-2600 (3361) AU
Singlemode light source KI-28010 and power meter
KI-2600. Compatible with APC and PC singlemode networks.
Wavelengths 1310, 1550 and 1625nm. Memory with text,
timestamp and USB dump, real-time PC reporting software.
Autotest provides fast, easy and automatic multi wavelength
loss testing.
Kingfisher KI78010 Single Mode APC
Light Source and KI7600 Power Meter
KIN,KI78010-7600 (3360) AU
Light source (KI78010) and power meter (KI7600) optical
fibre test set for single mode network and DWDM testing
at 1310, 1550 and 1625nm. LS (KI78010) has Angled SC,
FC and ST interchangeable connectors. PM (KI7600) with
InGaAs detector has large user memory and flexible real-time PC reporting
software. Autotest provides automatic multi wavelength loss testing. Power
meter can be used for multiple single and multimode wavelengths.
Kingfisher KI7822B- KI7600A Single Mode
Light Source & Power Meter
KIN,KI7822B-7600A (3362) AU
Light source (KI7822B) and power meter (KI7600A) optical
fibre test set for single mode applications (1310nm and
1550nm). Power meter has large user memory and flexible
real-time PC reporting software. Autotest provides automatic
multi wavelength loss testing. The meter displays mW, μW, nW, dB, dBm to
0.01dB resolution, with no range changing delays. Power meter can be used for
multiple single and multimode wavelengths. Laser output power 0dBm.
PDH/SDH Analysers cont’d.
JDSU SmartClass E1/Datacom Tester
JDSU,SMARTCLASS-E1-D AU
JDSU,SMARTCLASS MY
Handheld field tester for the installation and commissioning
of E1 and Datacom services. Applications include (not
limited to), G.703 - 2Mb/s testing, 2 M (Bulk), n x 64kb/s
BERT, audio monitoring (VF drop & insert),ABCD/Sa
monitoring,alarms(defects)anderrors(anomalies)insertion,
round-trip delay, DTE / DTE emulation and monitor mode.
Interfaces with X.21, V.24 (RS-232), V.35, V.36 (RS-449),
and EIA-530.
VeEx VePal TX130E+ DSn/PDH/Ethernet Analyser
VEEX,TX-130E+ MY
Full-featured Mobile test solution supporting legacy PDH/DSn and Carrier
Ethernet technologies. Provides E1 and 1G Ethernet Testing according to
RFC2544 standards.
VeEx VePal TX130M+ DSn/PDH/Ethernet Analyser
VEEX,TX-130M+ MY
Full-featured Mobile Backhaul test solution supporting
legacy PDH/DSn, Carrier Ethernet technologies, and
Synchronized Packet networks. The unit is capable of
emulating both Master and Slave clocks according to ITU-T
G.8261 SyncE and IEEE 1588v2 standards. At the same
time able to provide E1 and 1G Ethernet Testing according
to RFC2544 standards. It has options of Pulse Mask, E1
Wander and MTIE&TDEV.
VeEx VePal TX130+ E1 /Datacom Tester
VEEX,TX-130+ MY
Handheld field tester for installation and commissioning of E1 and Datacom
services. It is a small and compact unit.
DSL/POTS Test Set
Line and DSL Test Set
FLU,990DSL 2/2+ (3470) AU
CopperPro broad range Plain Old Telephone
Services (POTS) troubleshooting, fault location and line
qualification capabilities. Includes Wideband/TDR option
which adds high frequency transmission testing and
qualification functions for services like ADSL 2/2+, VDSL,
HDSL, HDSL2 & 4, ISDN, T1, E1 and DDS. TDR feature
adds precise fault location and analysis. Includes TN2100
remote terminator.
Light Sources & Power Meters
EXFO PPM-350B-EG PON Power Meter
EXFO,PPM350B MY
OptimiSed for FTTx E & GPON. PPM350B has 10 user-definable
threshold sets, each set consisting of three wavelengths (1310, 1490 and
1550 nm) having their own pass/warning/fail analysis features. Simultaneous
measurement and display of all PON signals voice, data and video.
EXFO PON/FTTx Power Meter & Inspection Probe
EXF,PPM352_FIP400 (3370) AU
Kit includes PPM-352B-EG-ER optimized for FTTx E
& GPON & FIP-400 inspection probe with handheld
display. PPM352 has 10 user-definable threshold sets, as
well as pass/warning/fail analysis features. Simultaneous
measurement and display of all PON signals voice, data and
video.
Data & Telecommunications www.techrentals.com.au
25. 23
Fusion Splicers
Fitel S123M12 Ribbon Fusion Splicer
FIT,S123M12 (3312) AU
Hand-held fusion splicer, can splice from 1 to a
maximum of 12-ribbon fibre. Protection sleeve shrink
time is 35 seconds for ribbon fibre sleeve, while splicing
requires only 15 seconds for 8 or 12 ribbon fibre
allowing up to 160 splicing cycles (splicing/heating)
using the 2 battery packs installed in the main body.
Includes S325 cleaver and thermal jacket stripper.
Fitel S178 Fusion Splicer and S325 Cleaver
FIT,S178_S325 (3314) AU
S178 hand-held, core-alignment fusion splicer and
S325 cleaver. Splicer provides typical losses of 0.02dB
and 0.01dB on single and multimode fibre respectively.
7 second splice time, built in heater and tension test.
Can be operated from battery or AC source. Precision
fibre cleaver can be used with single & multimode
fibres and features a built in sharps collection bin that
automatically stores fibre off-cuts.
Fujikura FSM60R Ribbon Fusion
Splicer, Cleaver, Stripper
FUJ,FSM60R-CT30 (3310) AU
Ribbon fibre fusion splicer, will splice from 1 to 12
fibres. Splice time 20 sec, sleeve shrink time 40
sec, typically. Detachable work table and arc-free
calibration system. Includes CT-30 fiber cleaver and
thermal jacket stripper.
Fujikura FSM60S Splicer & CT30 Cleaver
FUJ,FSM60S-CT30 (3320) AU/MY
Typical splice losses of 0.02dB and 0.01dB on single and
multimode fibre respectively. Features splice protection
heater, detachable work table and arc-free calibration
system.
Fujikura FSM70S Core Alignment
Fusion Splicer
FUJ,FSM70S (3318) AU
Single fibre core alignment fusion splicer and CT30A
cleaver. Typical splice losses of 0.02dB and 0.01dB
on single and multimode fibre respectively. Automated
tension test, wind and heater cover, 7 second splice time
and 14 second heat time.
OTDR & Fibre Inspection
See also LAN Cable Testers on page 20
Anritsu CMA 4500 Single &
Multimode 5/25dB OTDR
ANR,CMA4500SM-MM (3338) AU
Single mode and multimode OTDR. Includes
wavelengths multimode 850/1300nm (24/26dB) and
single mode 1310/1550 (35dB). Single mode port is
SC/APC. Ethernet, USB connectivity, 20GB HD and
PS2 ports. Touch screen and hard key interfaces.
OTDR & Fibre Inspection cont’d.
Fluke Optifiber Pro Multimode
OTDR
FLU,OPTIFIBER-PRO-MM (3343) AU
MMultimode OTDR, wavelengths 850 and 1300nm. Designed
for testing, troubleshooting and certifying multimode 50 and
62.5um fibre optic networks. Smartphone user interface,
shortest event and attenuation deadzones, LinkWare download
and reporting software included.
Fluke Optifiber Pro Quad OTDR
FLU,OPTIFIBER-PRO Q (3344) AU
Multi and singlemode OTDR,
wavelengths 850, 1300, 1310 and 1550nm. Designed for testing,
troubleshooting and certifying multi and singlemode 62.5,
50 and 9um fibre optic networks. Smartphone user interface,
shortest event and attenuation deadzones, LinkWare download
and reporting software included.
JDSU Fibre Inspection-Capture Probe
JDSU,FIBER_INSPECT (3340) AU
Handheld display, dual magnification (200/400x) probe
and USB adaptor for fibre end-face image analysis and
capture. Includes software and various probe tips.
JDSU MTS-4000 OTDR with
E4136FCOMP-MA
JDSU MTS-4000-FCOMP (3334) AU
Maintain metro and PON-based FTTx networks.
1310, 1550 and 1625nm wavelengths at 42, 40
and 40 dB dynamic range (respectively), includes
power meter, VFL, NBN auto test sequences and fibre inspection probe. Performs
insertion loss (IL), optical return loss (ORL) and OTDR from one optical port.
Applications include bidirectional testing, trouble shooting and acceptance testing.
Fibre Optic Launch
Cables & Patch Leads
Launch Fibre Multimode 50μm 100m
FIB,LAUNCH MM 50UM (3380) AU
100 metres of 50μm fibre terminated with SC connectors.
A launch fibre enables an OTDR to measure the loss
of the first connector and adapts a 62.5μm OTDR to a
50μm network.
Launch Fibre Multimode 62.5μm 300m
FIB,LAUNCH MM 62.5UM (3382) AU
SC to SC multimode 62.5μm launch fibre.
Launch Fibre Single Mode 9μm
FIB,LAUNCH SM 9UM (3378) AU
Single mode 9μm SC launch fibre.
Data & Telecommunicationswww.techrentals.com.au
Fibre optic consumables available for sale. Please
ask for delivery when placing your rental order.
26. 24
Cable & Pipe Tracers & Fault Locators
Electrical Testers
PAT Testers & RCD Testers
Micro-Ohm Meters & Earth Testers
Power Analysers, Loggers & Recorders
Current Clamps Probes & Accessories
Insulation Testers & Meggers to 20kV
Oil, Hipot & VLF Testers above 20kV
Circuit Breaker Testers
Transformer Testers
Current Injectors
Protection Relay Testing Systems
AC Sources/Inverters/Generators
Power Transformers & Variacs
Battery Management Systems
See also Ground Penetrating Radar on page 61
See also Underground Services Location on page 61
CScope CATXDSGV-KIT Cable and Pipe Locator
CSC,CATXDSGV-KIT (3730) AU/MY
Industry standard locator used to determine the exact
location of buried pipes and cables. Functions include:
Power mode for detecting live imbalanced cables to a
depth of 3m. Radio mode for detecting re-radiated radio
signals to a depth of 2m. Generator mode for detecting
conductors carrying the signal generated by the C.Scope
signal generator.
Fluke Cable Locator
FLU,2042 (3602) AU
Ideal for tracing cables in walls and underground, locating
fuses/breakers on final circuits as well as locating
interruptions and short-circuits in cables and electrical floor
heating systems. Can be used for tracing metallic water and
heating pipes. Supplied as a kit comprising a transmitter
and receiver in a carry case. Voltage measurement range
12 to 400 volts. Frequency range 0 to 60Hz. Transmitter output signal 125kHz.
Transmitter voltage 0 to 400V ac/dc. Depth location 0 to 2.5m. Receiver
voltage detection range 0 to 0.4m. The receiver incorporates a torch for
working in dimly lit locations.
Cable & Pipe Tracers
& Fault Locators cont’d.
Megger MPP1002 Cable Fault Pinpoint Locator
MEG,MPP1002-FAULT PP (3603) AU
Pinpoints faults in shielded and direct buried
primary cables via Geophone probe(s). Can
be used with any surge generator (thumper).
Stand-alone unit measures electromagnetic surge
and supplies the amplitude of that surge which aids in finding the fault. When
fitted with probes the unit will detect the acoustic discharge (thump), measure
the time delay between acoustic and electromagnetic signals and calculate
the distance to fault. Using the dual probe system the direction to fault is
indicated. Detects faults up to 23m away. Battery powered.
Megger TDR20002RM Dual Channel TDR Cable Fault Locator
MEG,TDR2000/2RM (3605) AU
Time Domain Reflectometer cable fault locator. User selectable ranges from
0 to 50m up to 20km, minimum resolution 0.1m. Dual cursor measurement.
Internal memory for 15 traces. Megger “Tracemaster” software supplied.
RS232 interface for PC communications. High resolution LCD display. Battery
powered. Dust and shower proof to IP54.
Riser Bond 1205T-OSP Metallic TDR Cable Fault Locator
RB,1205T-OSP MY
Dual input metallic time domain reflectometer cable fault locator for coaxial
cables. Maximum Range: 63,700ft (19,400meters) at .990 VOP. Distance
Accuracy: ±0.1ft (0.03m) plus ±.01% of reading. Can store, recall and
download waveform, via RS232 cable. (Viewable with Software.)
Electrical Testers
See also Current Clamps Probes & Accessories on page 31-32
ABB CB-2000
Portable Capacitance Meter
ABB,CB2000 (3500) AU
Portable (2.4kg) capacitance meter (0 - 1000μF) which
allows individual capacitors in a capacitor bank to be
measured without disconnection. Battery powered with an
ac adapter. Approximately 8 hours operating time between
charges. Supplied software and drivers allow measured
values to be exchanged to and from a PC via supplied USB
cable. Data stored as tab delimited text files.
Hioki 3283 Clamp on Leak HiTester
HIO,3283 MY
Monitor leak current fluctuations. Bandwidth 5Hz to 15kHz.
AC current range 10mA to 200A, resolution 10microA. Accuracy
±1%. LCD display. Battery powered.
Martindale Phase Sequence & Continuity
Indicator 100 to 600V, 50/60Hz
MAR,PSCI424-585 (3502) AU
Check the presence and sequence of the phases on
3ph circuits. Provides a visual indication of loss of
phase or incorrect sequence. Supplied in 2 forms.
Probe style; the connection to the tester is via 3
insulated cables to 3 fused test probes, 1 with an
insulated crocodile clip. Plug style; a 16A, 4 pin (3ph
& earth, BS4343) plug is fitted to the tester. Use as a
socket tester prior to plugging in 3ph equipment.
Cable & Pipe Tracers
& Fault Locators
Electrical Power www.techrentals.com.au
The film symbol indicates there
is a ‘how to video’ online for that
product, see page 1.