PUNJAB ENERGY DEVELOPMENT AGENCY
OFFICE BUILDING
CHANDIGARH
OUR WORK
IS NOT BASED ON ANY
PRE-CONCEIVED NOTION OF
ARCHITECTURE
• IT EVOLVES BASED
ON LAWS OF
NATURE
ARVIND KRISHAN
PERCEIVED SUN PATH
SUN PATH IS DYNAMIC & CURVILEANER WHY DO
WE DESIGN BUILDINGS AS CUBOIDS
?
SOLAR ENVELOPE
• Entire building envelope a : Solar Receptor, Converter, Dissipater
• SOLAR ENVELOPE
• SOLAR ENVELOPE CAN BE DESIGNED WITH COMPONENTS RESPONDING
TO :
 Produce direct energy through PV.
 Distribute day-light, within the building, creating a healthy day-lit
environment and in open spaces.
 Create ventilation: Solar Chimneys
 To cool or heat the building, when coupled with earth tunnels using the
thermal inertia of the earth and Trombe walls, in innovative approaches.
PEDA Office Chandigarh
PEDA OFFICE CHANDIGARH
GROUND FLOOR PLAN
SECTION
PEDA Office
Building Envelope in response to Solar geometry and Renewable Energy Systems Integration
FLOORS FLOATING IN A LARGE VOLUME OF AIR
PEDA Office Chandigarh, India –
A New Language of Sustainable Architecture
PEDA Office
HYPERBOLIC PARABOLOID SHELL
ROOF
HYPERBOLIC PARABOLOID
&
PERCEIVED SUN-PATH
SOLAR CHIMNEY
Energy Efficiency of a Reference Thermosyphon Collector (Solar
Chimney)
TEMPERATURE RISE AND EFFICIENCY
SOLAR CHIMNEY – under +overflow
PEDA Office
Solar Shells
day light for working areas
During Construction
Office Layout
Architecture – Structure Symbiosis
SUN GENERATES ARCHITECTURE - PEDA Office
Day lit Working Environment
VISUAL CONTINUITY
Fascinating Architecture
WIND TOWER
BIPV
Restful Working Environment
PHOTOVOLTAIC AS INTEGERAL COMPONENT OF ROOF
BIPV & HYPERBOLIC PARABOLOID ROOF
TYPICAL
CONNECTION
PHOTOVOLTAIC ROOF
DOUBLE SKINNED BUILDING ENVELOPE
INTER-STITIAL SPACE
-HEAT BARRIER THROUGH INSULATION / DEAD AIR CAVITY
-MOISTURE BARRIER
-T.A.P. (THERMOSYPHON AIR PANEL)
- THROUGH SOLAR / MECHANICAL ACTIVATION
INSIDE
THERMAL INNER SKIN
INTERACTS WITH INTERNAL
CONDITIONS
-AIR TEMP.
-HUMIDITY
-LIGHT
OUTSIDE
STRUCTURAL OUTER SKIN
INTERACTS WITH
EXTERNAL CONDITIONS
-WEATHER
-RADIATION
-HUMIDITY
-AIR TEMP.
-U.V.
K14 CSP Case Study Project : Opriya Mohanty UNVERSITY OF NOTTINGHAM U.K.
Performance of downdraught evaporative cooling system in atrium and its neighboring
office space, (PEDA) building – Chandigarh, India.
Objective
An investigation into the contribution of PHDC system in
the atrium and its space conditioning systems to the
thermal comfort in their adjacent office spaces in the
Punjab Energy Development Agency building (PEDA).
Introduction
The Office complex building for PEDA at Chandigarh, India is
a project aimed at demonstrating an architectural design
developed in response to elements of nature : Sun, wind,
light and the utilization Of Solar Passive Systems.
Context & Site microclimatic analysis
Architectural building design needs to respond to the
composite climatic context of the site. The final design
solution needs to satisfy the diverse and often conflicting
conditions of a hot-dry, hot-humid, temperate and cold
period of Chandigarh.
The climatic periods : two months of hot-dry, hot-humid
(two months) and cold period (two months) require
strategies of design that allow for cooling in the hot dry
period, natural ventilation in the hot-humid period and
heating in the cold period. Cooling remains as the
predominant requirement since the total over-heated
period extends from mid-April to mid-August.
The comfort temperature varies during whole year, but the
maximum comfort temperature in summer varies from 29 c
to 31 c when external temperature varies from 40 c to 45c.
hence we need to design the building to achieve
comfortable temperature by keeping the highest or hottest
week of the year in mind to avoid the overheating inside
the space.
Psychometric chart
Temperature and rain fall variation
Average Insolation Summer
WIND SPEED AND DIRECTION
should be taken in to consideration while designing the wind
tower and building openings,
Architect has taken priority during placement of wind tower
as well as the openings for better movement of air flow
Over shadowing analysis
Building is not overshadowed by its surrounding building, due to its
orientatiion and well designed facades ,building is having its own
shadow during summer which helps to minimise the over heating.
Winter solstice
Equinox
Summer solstice
Shell roof in atrium space to minimize overheating and
uniform daylighting
Ventilation system in atrium and office space
through wind tower and solar chimney
during summer day and night
Daylight study in U. Ground office space
Simulation through PHDC air
flow tool
PASSIVE DOWN DRAFT INDIRECT+ DIRECT EVAPORATIVE
COOLING COUPLED WITH EARTH AIR TUNNEL UNDER THE
WATER BODY ( Architect’s design idea)
Results
The comfort temperature range varies from 24 to 31 during different seasons of the year. Comfort relative humidity range 30to 80 %. Required air flow rate as from manual calculations can be 3.5 m3/sec. so the air flow rate can be
achieved in all the cases. Required airflow rate is very low due to less occupancy and equipment gain. Good thermal mass of the building helps the building to perform in extreme conditions. Appropriate building design and orientation
having properly placed building elements reduced or minimize the solar gain in summer. Features like light Vault, Solar chimney, Hyperbolic parabolised atrium roof help to minimize the solar gain. Instead of designing indirect plus direct
evaporative cooling system proposed by the architect, PDEC system can be used to make the building favorable place to work. From the above results it can be concluded that the temperature, relative humidity and airflow rate increase
from case 1 to case 3 which leads to unsuccessful result. Hence the central atrium space in between neighboring offices is working properly having PDEC system with one tower and it would be the best option to work with. From all the
cases we can conclude that ground office space also getting an ambient temperature during summer.
Comparison study of different cases
Result - Hottest day 161
Conclusion
Evaporative cool towers work best with open floor plans that permit the air to circulate through out the building without any obstacles. From the TAS result it can be concluded that the atrium
space is working properly with application of PDEC system by getting 10-12°C lower than ambient temperature, which also helps to cool the neighboring south office space to maintain a
comfortable space to work. From all evidences Punjab energy development agency (PEDA) can be called as a passive solar complex. Overall the building performs well whole of the year except
the peak summer period which can be improved through the evaporative cooling system.Hence Without any major changes in building profile and structure ,we can rebuilt the existing wind
tower and solar chimneys by incorporating the PDEC system ,which can perform better during hot and dry summer days.
•Evaporative cooling towers work best with open floor plans that permit the air to
circulate through out the building without any obstacles.
•Good thermal mass of the building helps the building to perform in extreme
conditions. Appropriate building design and orientation having properly placed
building elements reduced or minimize the solar gain in summer.
•Elements like light Vault, Solar chimney, Hyperbolic parabolised atrium roof help
to minimize the solar gain.
•From the TAS result it can be concluded that the atrium space is working properly
with application of PDEC system by getting 10-12°C lower than ambient
temperature, which also helps to cool the neighboring south office space to
maintain a comfortable space to work.
• From all evidences Punjab Energy Development Agency (PEDA)
office building can be called as a passive solar complex. Overall the
building performs well whole of the year. Evaporative cooling is
required in May & June
CONCLUSIONS
5 STAR
RATING 2010
BASED ON
ACTUAL PERFORMANCE
14 kwh /sq.m/per year
.
BUREAU OF
ENERGY EFFICIENCY
GOVT. OF INDIA
Most Energy Efficient Building
in the country
Tribune : May 2004
Tribune : Jan 2004 HRH Prince Charles Visit October 2010
Round table discussion
TO MY MIND
GOOD MEANINGFUL
ARCHITECTURE
EVOLVES AT MEETING POINT:
WHEN ART BECOMES SCIENCE AND SCIENCE
BECOMES ART
ARVIND KRISHAN
AT THIS POINT
LOFTY BECOMES MUNDANE
&
MUNDANE LOFTY
ARVIND KRISHAN

More Related Content

What's hot

university campus design
university campus design university campus design
university campus design iqraabishah
 
INFOSYS GREEN BUILDING
INFOSYS GREEN BUILDINGINFOSYS GREEN BUILDING
INFOSYS GREEN BUILDINGgatti Teja
 
Case study of international architecture college
Case study of international architecture collegeCase study of international architecture college
Case study of international architecture collegeNilanjana Pal
 
The british school design case study
The british school design case studyThe british school design case study
The british school design case studyChandan kumar
 
Retreat (Resource Efficient TERI Retreat for Environmental Awareness and Trai...
Retreat (Resource Efficient TERI Retreat for Environmental Awareness and Trai...Retreat (Resource Efficient TERI Retreat for Environmental Awareness and Trai...
Retreat (Resource Efficient TERI Retreat for Environmental Awareness and Trai...Soumi Bera
 
CII- SOHRABJI GODREJ GREEN BUSINESS CENTER CASE STUDY PPT
CII- SOHRABJI GODREJ GREEN BUSINESS CENTER CASE STUDY PPT CII- SOHRABJI GODREJ GREEN BUSINESS CENTER CASE STUDY PPT
CII- SOHRABJI GODREJ GREEN BUSINESS CENTER CASE STUDY PPT vk78512
 
Indira paryavaran bhawan
Indira paryavaran bhawanIndira paryavaran bhawan
Indira paryavaran bhawanpraveen rohilla
 
Green building Manipal University
Green building  Manipal UniversityGreen building  Manipal University
Green building Manipal UniversitySiddiq Salim
 
Courtyards Planning in Indian Context
Courtyards Planning in Indian Context Courtyards Planning in Indian Context
Courtyards Planning in Indian Context Mayur Waghulde
 
Case study on Energy Efficient Building PEDA Office Complex at Chandigarh, India
Case study on Energy Efficient Building PEDA Office Complex at Chandigarh, IndiaCase study on Energy Efficient Building PEDA Office Complex at Chandigarh, India
Case study on Energy Efficient Building PEDA Office Complex at Chandigarh, IndiaShabana Kotta
 
Passive Architecture Case Examples
Passive Architecture Case ExamplesPassive Architecture Case Examples
Passive Architecture Case ExamplesHarpreet Oberoi
 
case study of School of planning and architecture, delhi
case study of School of planning and architecture, delhicase study of School of planning and architecture, delhi
case study of School of planning and architecture, delhiFaizan Ahmad
 
Iim bangalore (passive india)
Iim bangalore (passive india)Iim bangalore (passive india)
Iim bangalore (passive india)Mudra Redkar
 
Case study selaqui school doon
Case study selaqui school doonCase study selaqui school doon
Case study selaqui school doonDeepikaAgarwal42
 
Sangath- An Architect's Studio
Sangath- An Architect's StudioSangath- An Architect's Studio
Sangath- An Architect's StudioVidisha Barwal
 
American institute of indian studies. Lighting.
American institute of indian studies. Lighting.American institute of indian studies. Lighting.
American institute of indian studies. Lighting.sanjaydeovrat
 
Data collection - Climate Analysis - Tropical Wet and Dry Climate - Architect...
Data collection - Climate Analysis - Tropical Wet and Dry Climate - Architect...Data collection - Climate Analysis - Tropical Wet and Dry Climate - Architect...
Data collection - Climate Analysis - Tropical Wet and Dry Climate - Architect...LipikaPandey
 
architectural design theory
architectural design theoryarchitectural design theory
architectural design theorytanya jangra
 

What's hot (20)

university campus design
university campus design university campus design
university campus design
 
Cept case study
Cept case studyCept case study
Cept case study
 
INFOSYS GREEN BUILDING
INFOSYS GREEN BUILDINGINFOSYS GREEN BUILDING
INFOSYS GREEN BUILDING
 
Case study of international architecture college
Case study of international architecture collegeCase study of international architecture college
Case study of international architecture college
 
The british school design case study
The british school design case studyThe british school design case study
The british school design case study
 
Retreat (Resource Efficient TERI Retreat for Environmental Awareness and Trai...
Retreat (Resource Efficient TERI Retreat for Environmental Awareness and Trai...Retreat (Resource Efficient TERI Retreat for Environmental Awareness and Trai...
Retreat (Resource Efficient TERI Retreat for Environmental Awareness and Trai...
 
CII- SOHRABJI GODREJ GREEN BUSINESS CENTER CASE STUDY PPT
CII- SOHRABJI GODREJ GREEN BUSINESS CENTER CASE STUDY PPT CII- SOHRABJI GODREJ GREEN BUSINESS CENTER CASE STUDY PPT
CII- SOHRABJI GODREJ GREEN BUSINESS CENTER CASE STUDY PPT
 
Indira paryavaran bhawan
Indira paryavaran bhawanIndira paryavaran bhawan
Indira paryavaran bhawan
 
Green building Manipal University
Green building  Manipal UniversityGreen building  Manipal University
Green building Manipal University
 
IIM Bangalore
IIM BangaloreIIM Bangalore
IIM Bangalore
 
Courtyards Planning in Indian Context
Courtyards Planning in Indian Context Courtyards Planning in Indian Context
Courtyards Planning in Indian Context
 
Case study on Energy Efficient Building PEDA Office Complex at Chandigarh, India
Case study on Energy Efficient Building PEDA Office Complex at Chandigarh, IndiaCase study on Energy Efficient Building PEDA Office Complex at Chandigarh, India
Case study on Energy Efficient Building PEDA Office Complex at Chandigarh, India
 
Passive Architecture Case Examples
Passive Architecture Case ExamplesPassive Architecture Case Examples
Passive Architecture Case Examples
 
case study of School of planning and architecture, delhi
case study of School of planning and architecture, delhicase study of School of planning and architecture, delhi
case study of School of planning and architecture, delhi
 
Iim bangalore (passive india)
Iim bangalore (passive india)Iim bangalore (passive india)
Iim bangalore (passive india)
 
Case study selaqui school doon
Case study selaqui school doonCase study selaqui school doon
Case study selaqui school doon
 
Sangath- An Architect's Studio
Sangath- An Architect's StudioSangath- An Architect's Studio
Sangath- An Architect's Studio
 
American institute of indian studies. Lighting.
American institute of indian studies. Lighting.American institute of indian studies. Lighting.
American institute of indian studies. Lighting.
 
Data collection - Climate Analysis - Tropical Wet and Dry Climate - Architect...
Data collection - Climate Analysis - Tropical Wet and Dry Climate - Architect...Data collection - Climate Analysis - Tropical Wet and Dry Climate - Architect...
Data collection - Climate Analysis - Tropical Wet and Dry Climate - Architect...
 
architectural design theory
architectural design theoryarchitectural design theory
architectural design theory
 

Similar to Project Punjab Energy Development Agency, Office Building, Chandigarh

Composite Climatic zone presentation.pptx
Composite Climatic zone presentation.pptxComposite Climatic zone presentation.pptx
Composite Climatic zone presentation.pptxRaahatGupta3
 
Torrent research building spa
Torrent research building spaTorrent research building spa
Torrent research building spaShamitha Reddy
 
Case study climatology (india habitat centre & peda)
Case study  climatology (india habitat centre & peda)Case study  climatology (india habitat centre & peda)
Case study climatology (india habitat centre & peda)Chandan kumar
 
CASE STUDY OF PEDA OFFICE COMPLEX, CHANDIGARH.pdf
CASE STUDY OF PEDA OFFICE COMPLEX, CHANDIGARH.pdfCASE STUDY OF PEDA OFFICE COMPLEX, CHANDIGARH.pdf
CASE STUDY OF PEDA OFFICE COMPLEX, CHANDIGARH.pdfAbhishekkumar354689
 
CASE STUDY OF PEDA OFFICE COMPLEX, CHANDIGARH.pdf
CASE STUDY OF PEDA OFFICE COMPLEX, CHANDIGARH.pdfCASE STUDY OF PEDA OFFICE COMPLEX, CHANDIGARH.pdf
CASE STUDY OF PEDA OFFICE COMPLEX, CHANDIGARH.pdfAbhishekkumar354689
 
Need of climate responsive measures for buildings
Need of climate responsive measures for buildingsNeed of climate responsive measures for buildings
Need of climate responsive measures for buildingsSukhneet Kaur
 
Paper presentation
Paper presentationPaper presentation
Paper presentationabc def
 
Review of Retrofitting of Academic Building by Energy Efficient Techniques
Review of Retrofitting of Academic Building by Energy Efficient TechniquesReview of Retrofitting of Academic Building by Energy Efficient Techniques
Review of Retrofitting of Academic Building by Energy Efficient TechniquesIRJET Journal
 
Passive Cooling Techniques in Commercial Building.pptx
Passive Cooling Techniques in Commercial Building.pptxPassive Cooling Techniques in Commercial Building.pptx
Passive Cooling Techniques in Commercial Building.pptxRiyaVerma238431
 
Building services optimization
Building services optimizationBuilding services optimization
Building services optimizationAnupama Krishnan
 
2007-Green Buildings-HVAC Guidelines.ppt
2007-Green Buildings-HVAC Guidelines.ppt2007-Green Buildings-HVAC Guidelines.ppt
2007-Green Buildings-HVAC Guidelines.pptRAMIREDDY49
 
Green Building Case Study on TERI,bangalore.
Green Building Case Study on TERI,bangalore.Green Building Case Study on TERI,bangalore.
Green Building Case Study on TERI,bangalore.Vinay M
 
Research paper a.a
Research paper a.aResearch paper a.a
Research paper a.aKaizer Ooi
 
greenbuildingscasestudy-170601100637.pptx
greenbuildingscasestudy-170601100637.pptxgreenbuildingscasestudy-170601100637.pptx
greenbuildingscasestudy-170601100637.pptxssuser25a32e
 
Zero energy buildings seminar
Zero energy buildings seminarZero energy buildings seminar
Zero energy buildings seminarSharan Raj
 
natural ventilation case study
natural ventilation case studynatural ventilation case study
natural ventilation case studyMADHUKANT SINGH
 

Similar to Project Punjab Energy Development Agency, Office Building, Chandigarh (20)

Composite Climatic zone presentation.pptx
Composite Climatic zone presentation.pptxComposite Climatic zone presentation.pptx
Composite Climatic zone presentation.pptx
 
Torrent research building spa
Torrent research building spaTorrent research building spa
Torrent research building spa
 
Case study climatology (india habitat centre & peda)
Case study  climatology (india habitat centre & peda)Case study  climatology (india habitat centre & peda)
Case study climatology (india habitat centre & peda)
 
CASE STUDY OF PEDA OFFICE COMPLEX, CHANDIGARH.pdf
CASE STUDY OF PEDA OFFICE COMPLEX, CHANDIGARH.pdfCASE STUDY OF PEDA OFFICE COMPLEX, CHANDIGARH.pdf
CASE STUDY OF PEDA OFFICE COMPLEX, CHANDIGARH.pdf
 
CASE STUDY OF PEDA OFFICE COMPLEX, CHANDIGARH.pdf
CASE STUDY OF PEDA OFFICE COMPLEX, CHANDIGARH.pdfCASE STUDY OF PEDA OFFICE COMPLEX, CHANDIGARH.pdf
CASE STUDY OF PEDA OFFICE COMPLEX, CHANDIGARH.pdf
 
Need of climate responsive measures for buildings
Need of climate responsive measures for buildingsNeed of climate responsive measures for buildings
Need of climate responsive measures for buildings
 
Paper presentation
Paper presentationPaper presentation
Paper presentation
 
Review of Retrofitting of Academic Building by Energy Efficient Techniques
Review of Retrofitting of Academic Building by Energy Efficient TechniquesReview of Retrofitting of Academic Building by Energy Efficient Techniques
Review of Retrofitting of Academic Building by Energy Efficient Techniques
 
Passive Cooling Techniques in Commercial Building.pptx
Passive Cooling Techniques in Commercial Building.pptxPassive Cooling Techniques in Commercial Building.pptx
Passive Cooling Techniques in Commercial Building.pptx
 
Building services optimization
Building services optimizationBuilding services optimization
Building services optimization
 
2007-Green Buildings-HVAC Guidelines.ppt
2007-Green Buildings-HVAC Guidelines.ppt2007-Green Buildings-HVAC Guidelines.ppt
2007-Green Buildings-HVAC Guidelines.ppt
 
Ashok B Lal
Ashok B LalAshok B Lal
Ashok B Lal
 
Green Building Case Study on TERI,bangalore.
Green Building Case Study on TERI,bangalore.Green Building Case Study on TERI,bangalore.
Green Building Case Study on TERI,bangalore.
 
Vinay M
Vinay MVinay M
Vinay M
 
CASE STUDY.pdf
CASE STUDY.pdfCASE STUDY.pdf
CASE STUDY.pdf
 
Research paper a.a
Research paper a.aResearch paper a.a
Research paper a.a
 
greenbuildingscasestudy-170601100637.pptx
greenbuildingscasestudy-170601100637.pptxgreenbuildingscasestudy-170601100637.pptx
greenbuildingscasestudy-170601100637.pptx
 
Zero energy buildings seminar
Zero energy buildings seminarZero energy buildings seminar
Zero energy buildings seminar
 
Green buildings case study
Green buildings case studyGreen buildings case study
Green buildings case study
 
natural ventilation case study
natural ventilation case studynatural ventilation case study
natural ventilation case study
 

Project Punjab Energy Development Agency, Office Building, Chandigarh

  • 1. PUNJAB ENERGY DEVELOPMENT AGENCY OFFICE BUILDING CHANDIGARH
  • 2. OUR WORK IS NOT BASED ON ANY PRE-CONCEIVED NOTION OF ARCHITECTURE • IT EVOLVES BASED ON LAWS OF NATURE ARVIND KRISHAN
  • 3. PERCEIVED SUN PATH SUN PATH IS DYNAMIC & CURVILEANER WHY DO WE DESIGN BUILDINGS AS CUBOIDS ?
  • 4. SOLAR ENVELOPE • Entire building envelope a : Solar Receptor, Converter, Dissipater • SOLAR ENVELOPE • SOLAR ENVELOPE CAN BE DESIGNED WITH COMPONENTS RESPONDING TO :  Produce direct energy through PV.  Distribute day-light, within the building, creating a healthy day-lit environment and in open spaces.  Create ventilation: Solar Chimneys  To cool or heat the building, when coupled with earth tunnels using the thermal inertia of the earth and Trombe walls, in innovative approaches.
  • 6. PEDA OFFICE CHANDIGARH GROUND FLOOR PLAN SECTION
  • 7. PEDA Office Building Envelope in response to Solar geometry and Renewable Energy Systems Integration
  • 8. FLOORS FLOATING IN A LARGE VOLUME OF AIR
  • 9.
  • 10. PEDA Office Chandigarh, India – A New Language of Sustainable Architecture
  • 13.
  • 14.
  • 15. SOLAR CHIMNEY Energy Efficiency of a Reference Thermosyphon Collector (Solar Chimney) TEMPERATURE RISE AND EFFICIENCY SOLAR CHIMNEY – under +overflow
  • 16. PEDA Office Solar Shells day light for working areas During Construction
  • 19. SUN GENERATES ARCHITECTURE - PEDA Office
  • 20. Day lit Working Environment
  • 23.
  • 26. PHOTOVOLTAIC AS INTEGERAL COMPONENT OF ROOF
  • 27. BIPV & HYPERBOLIC PARABOLOID ROOF
  • 29. DOUBLE SKINNED BUILDING ENVELOPE INTER-STITIAL SPACE -HEAT BARRIER THROUGH INSULATION / DEAD AIR CAVITY -MOISTURE BARRIER -T.A.P. (THERMOSYPHON AIR PANEL) - THROUGH SOLAR / MECHANICAL ACTIVATION INSIDE THERMAL INNER SKIN INTERACTS WITH INTERNAL CONDITIONS -AIR TEMP. -HUMIDITY -LIGHT OUTSIDE STRUCTURAL OUTER SKIN INTERACTS WITH EXTERNAL CONDITIONS -WEATHER -RADIATION -HUMIDITY -AIR TEMP. -U.V.
  • 30. K14 CSP Case Study Project : Opriya Mohanty UNVERSITY OF NOTTINGHAM U.K. Performance of downdraught evaporative cooling system in atrium and its neighboring office space, (PEDA) building – Chandigarh, India. Objective An investigation into the contribution of PHDC system in the atrium and its space conditioning systems to the thermal comfort in their adjacent office spaces in the Punjab Energy Development Agency building (PEDA). Introduction The Office complex building for PEDA at Chandigarh, India is a project aimed at demonstrating an architectural design developed in response to elements of nature : Sun, wind, light and the utilization Of Solar Passive Systems. Context & Site microclimatic analysis Architectural building design needs to respond to the composite climatic context of the site. The final design solution needs to satisfy the diverse and often conflicting conditions of a hot-dry, hot-humid, temperate and cold period of Chandigarh. The climatic periods : two months of hot-dry, hot-humid (two months) and cold period (two months) require strategies of design that allow for cooling in the hot dry period, natural ventilation in the hot-humid period and heating in the cold period. Cooling remains as the predominant requirement since the total over-heated period extends from mid-April to mid-August. The comfort temperature varies during whole year, but the maximum comfort temperature in summer varies from 29 c to 31 c when external temperature varies from 40 c to 45c. hence we need to design the building to achieve comfortable temperature by keeping the highest or hottest week of the year in mind to avoid the overheating inside the space. Psychometric chart Temperature and rain fall variation Average Insolation Summer
  • 31. WIND SPEED AND DIRECTION should be taken in to consideration while designing the wind tower and building openings, Architect has taken priority during placement of wind tower as well as the openings for better movement of air flow Over shadowing analysis Building is not overshadowed by its surrounding building, due to its orientatiion and well designed facades ,building is having its own shadow during summer which helps to minimise the over heating. Winter solstice Equinox Summer solstice
  • 32. Shell roof in atrium space to minimize overheating and uniform daylighting Ventilation system in atrium and office space through wind tower and solar chimney during summer day and night Daylight study in U. Ground office space Simulation through PHDC air flow tool PASSIVE DOWN DRAFT INDIRECT+ DIRECT EVAPORATIVE COOLING COUPLED WITH EARTH AIR TUNNEL UNDER THE WATER BODY ( Architect’s design idea) Results The comfort temperature range varies from 24 to 31 during different seasons of the year. Comfort relative humidity range 30to 80 %. Required air flow rate as from manual calculations can be 3.5 m3/sec. so the air flow rate can be achieved in all the cases. Required airflow rate is very low due to less occupancy and equipment gain. Good thermal mass of the building helps the building to perform in extreme conditions. Appropriate building design and orientation having properly placed building elements reduced or minimize the solar gain in summer. Features like light Vault, Solar chimney, Hyperbolic parabolised atrium roof help to minimize the solar gain. Instead of designing indirect plus direct evaporative cooling system proposed by the architect, PDEC system can be used to make the building favorable place to work. From the above results it can be concluded that the temperature, relative humidity and airflow rate increase from case 1 to case 3 which leads to unsuccessful result. Hence the central atrium space in between neighboring offices is working properly having PDEC system with one tower and it would be the best option to work with. From all the cases we can conclude that ground office space also getting an ambient temperature during summer. Comparison study of different cases Result - Hottest day 161 Conclusion Evaporative cool towers work best with open floor plans that permit the air to circulate through out the building without any obstacles. From the TAS result it can be concluded that the atrium space is working properly with application of PDEC system by getting 10-12°C lower than ambient temperature, which also helps to cool the neighboring south office space to maintain a comfortable space to work. From all evidences Punjab energy development agency (PEDA) can be called as a passive solar complex. Overall the building performs well whole of the year except the peak summer period which can be improved through the evaporative cooling system.Hence Without any major changes in building profile and structure ,we can rebuilt the existing wind tower and solar chimneys by incorporating the PDEC system ,which can perform better during hot and dry summer days.
  • 33. •Evaporative cooling towers work best with open floor plans that permit the air to circulate through out the building without any obstacles. •Good thermal mass of the building helps the building to perform in extreme conditions. Appropriate building design and orientation having properly placed building elements reduced or minimize the solar gain in summer. •Elements like light Vault, Solar chimney, Hyperbolic parabolised atrium roof help to minimize the solar gain. •From the TAS result it can be concluded that the atrium space is working properly with application of PDEC system by getting 10-12°C lower than ambient temperature, which also helps to cool the neighboring south office space to maintain a comfortable space to work. • From all evidences Punjab Energy Development Agency (PEDA) office building can be called as a passive solar complex. Overall the building performs well whole of the year. Evaporative cooling is required in May & June CONCLUSIONS
  • 34. 5 STAR RATING 2010 BASED ON ACTUAL PERFORMANCE 14 kwh /sq.m/per year . BUREAU OF ENERGY EFFICIENCY GOVT. OF INDIA Most Energy Efficient Building in the country
  • 35. Tribune : May 2004 Tribune : Jan 2004 HRH Prince Charles Visit October 2010 Round table discussion
  • 36.
  • 37.
  • 38. TO MY MIND GOOD MEANINGFUL ARCHITECTURE EVOLVES AT MEETING POINT: WHEN ART BECOMES SCIENCE AND SCIENCE BECOMES ART ARVIND KRISHAN
  • 39. AT THIS POINT LOFTY BECOMES MUNDANE & MUNDANE LOFTY ARVIND KRISHAN