Broadband System – O
                           Satellites are spaced every
                            2nd degrees above earth


"C" Band
Toward satellite 6.0 GHz                                 "L" Band
Toward earth 4.0 GHz                                     Toward satellite 14.0 GHz
                                                         Toward earth 12.0 GHz




                TV
            TRANSMITTER
                           Headend

                                       Cable area

                                                                                     1
                    CLI Cumulative Leakage Index
Cumulative Leakage Index




                           2
Leakage Terminology


•Radiation.
•Egress
•Ingress
•Leakage
•uV M (Micro volts per Meter)
•CLI (Cumulative Leakage Index)



                                  3
Ingress / Egress


Ingress:
RF signal leaking into the coaxial plant.




Egress:
RF signal leaking out of the coaxial plant.



                                              4
Reasons to monitor leakage




1. Prevent Off-Air Broadcast Interference.
2. To meet government compliance.
3. To give our customer better quality of signal.




                                                    5
Spectrum Charts


           108 MHz.             118 MHz            137 MHz

Off-Air    Air navigation           Air voice communications

Cable      Ch: 98 - 99                    Ch: 14 - 15 - 16




             144 MHz.           162 MHz           174 MHz

Off-Air   Ham Operators            Government mobile

Cable                   Ch: 18 - 19 - 20 - 21 - 22




                                                               6
Spectrum Charts



            225 MHz.                                400 MHz.
Off-Air          Military Air voice communication
Cable Ch:                See below.


•155.34 MHz - Nationwide Hospital / Ambulance Radio Link
•156.80 MHz - Marine Emergency Aircraft Survival Locator.
•243.00 MHz - Emergency Aircraft Survival Locator.




                                                               7
Signal Leakage History



•   Mid-band expansion.
•   Aeronautical interference discover (1976)
•   Frequency offsets (1979)
•   Radian dome (1980)
•   Mandatory FCC / DOC enforcement (1980s)
•   Cumulative Leakage Index (1990)




                                                8
Cumulative Leakage Index CLI


 CLI is the net effect of the combination of all
   the leaks in the system added together.




These cumulative leaks form an invisible cloud
of unwanted RF energy over the cable system.

                                                   9
CLI Rules (Quarterly)



•Ride out 100% of system and log all leaks.
•Log should include Date found and Date fixed.
•Documenting leakage level isn't required for this drive out.


•Actual practice for your system may vary!




                                                                10
CLI Rules (Annually)



•Ride out 75% of the oldest part of the system and log all leaks
location and measured level.
•Must be performed within a reasonable period of time
(Usually within 2 wks of due date)


•Actual practice for your system may vary!




                                                              11
The only acceptable procedure for leakage
      measurement by the government rule.




•Use a calibrated half wave dipole antenna.
•Antenna must be elevated 3 meters off the ground and
positioned 3 meters from the leakage source.
•Antenna must be rotated 360° in the horizontal plane for
maximum reading.




                                                            12
Required actions.




•All leaks above 20uV/m must be logged and fixed.
•Only leaks above 50uV/m are used in CLI calculation.
•All measurements taken outside 108 – 137 MHz must be
converted as if they were taken within the band.




                                                        13
uV/M (Microvolts per Metre)



•Standard unit of measure for CLI


•50 Ohm off air measurement.


•Voltage developed in 1 meter of infinitely, this section of
wire submerged in a leakage field produces 1uV of energy.




                                                               14
C.L.I.



•Cumulative Leakage Index.
•Mathematical summation of leakage in a system designed to
approximate the interference to aircraft flying overhead.
•Figure of merit for system performance.
•One leak of 1588uV/M within a system is enough to fail C.L.I.




                                                                 15
Cumulative Leakage Index.




10XLOG ( Total Plant ) X ( sum of Leak²)
        Miles Driven

    Compliance = 64 leaks or less.




                                           16
BP-23 for Canadian Operator.

3.2 Leakage Control
3.2.1     At all times, cable system operators should strive to minimized emanating
from their facilities.
3.2.2     The operator of a cable television system distributing signals over
supplementary channels must carry out a systematic patrols to detect leakage, and
take corrective measures to prevent leakage.
3.2.3     The operator of a cable television system must keep a logbook indicating
the date and location foe each leak detected, the date on which it was repaired and its
probable cause. This logbook must be kept for a period of two years so that it may be
examined by an inspector from the Department upon request.
3.2.4     When leakage originates from a subscriber’s premises, the system operator
must ensure the necessary repairs are carried out. If such repairs cannot be effected
within a reasonable period of time, the operator must stop distribution of the
interfering service(s) or channel(s) to the subscriber’s premises until the leakage can
be repaired. In addition, distribution of interfering of service(s) or channel(s) to
subscriber’s premises must be stopped immediately if the leakage originating from
the subscriber endanger safety services (ambulance, police, aeronautical frequencies,
and so on)
                                                                                 17
BP-23 for Canadian Operator.
4.1 General Provisions
4.11    Unless indicated otherwise, all technical standards stated herein apply to the
requirements respecting performance between the cable television system input and
any subscriber terminal.
4.1.2    All technical standards specified herein relate to the measurement procedure
discussed in this document, and, where appropriate, apply in the presence of all
signals usually carried on the system.

4.2 Leakage Criteria
4.2.1   The following leakage criteria are used to evaluate cable system leakage
performance.
4.2.2    The Equivalent Leakage Density estimates the impact of signal leakage on
land-based radio system- I.e. police, ambulance service, etc.- which share spectrum
with cable television systems. The ELD criterion ensures that all cable systems meet a
leakage performance intended to minimize interference to land-radio system.
4.2.3     The Cumulative Leakage Index (CLI) estimates the cumulative impact of
leakage on aeronautical spectrum users. When the signal leakage measurements are
taken on the ground, the CLI ground-based criterion (CLIg) is used. If the
measurements are taken in the airspace above the cable system, the CLI air-based
criterion (CLIa) is used to estimate this impact. Both criteria apply to cable system
carrying A-1(99), A-2(98), EE941) and FF(42)
                                                                               18
BP-23 for Canadian Operator.




http://strategis.ic.gc.ca/epic/internet/insmt-gst.nsf/vwapj/bpr8e.pdf/$FILE/bpr8e.pdf

       You can get this procedure at the above internet link
                                                                                        19
BP-23 for Canadian Operator.


4.3 Equivalent Leakage Density (ELD)
For the purposes of calculating the Equivalent Leakage Density,
leakage readings are classified into three categories, each of which
has it corresponding weighting factor, as shown in the table below.




                                                                       20
BP-23 for Canadian Operator.

4.3.2    The ELD is calculated using the following formula:
         ELD = (N1 X 1) + (N2 X 2) + N3 X 3),
                           K
         where:
         ELD = Equivalent Leakage Density
         N1 = Number of leaks in Category A (50 – 220 uV/m)
         N2 = Number of leaks in Category B (201 – 500 uV/m)
         N3 = Number of leaks in Category C (>500 uV/m)
         1 = Category A weighting factor
         2 = Category B weighting factor
         3 = Category C weighting factor
         K = Number of kilometres patrolled.
4.3.3     For the purposes of ELD calculations, only leaks equal to or
grater than 50 uV/ at 3 metres need to be taken into account.
                                                                         21
BP-23 for Canadian Operator.

4.4 Equivalent Leakage Density Application Schedule.
Table 4.2 shows the ELD limits applications schedule. The beginning
of the first implementation period coincides with the effective date of
this document. Cable systems will have to the end of each
implementation period to reach the ELD limit that applies for that
period. The maximum limit after 6 years is 0.8.




                                                                          22
BP-23 for Canadian Operator.
 4.5 CLI Ground-Based Criterion (CLIg)
 4.5.1     The computed CLIg must not be over 64.
 4.5.2     The CLIg is calculated using the following formulas:




Where:
CLIg = CLI ground-based criterion, taking into the surface area of
the system
F(S) = Correction factor for the surface area
Ei = Filed strength of the ith leak measured at 3 metres, in uV/m
S = Surface area covered by the cable system in km²
N = Number of leaks detected

4.5.3     While all leaks, regardless of magnitude, must be
repaired, it is not necessary to take into account leaks of less than
50 uV/m at 3 metres when calculating the CLIg                           23
BP-23 for Canadian Operator.

  4.6 CLI Air-Based criterion (CLIa)
  The CLIa is the 90th-percentile value of the field strength due to
  cable leaks and it must not exceed 10 microvolts per metre RMS at
  an altitude of 450 metres above the cable system’s average ground
  level.

  4.7 Carrier-to-Noise ratio
  The carrier-to-noise ration for each television channel received at
  any subscriber terminal must not be less than 40 dB.



The full BP-23 can be downloaded at the internet address below:

   http://strategis.ic.gc.ca/SSG/sf01209e.html


                                                                        24
Patrolling for Leakage




    20uV/m      10 feet



                          100 feet




    2 uV/m




                                     25
Calibrating Leakage Detection Equipment.




  1. Connect calibrated signal source set at 20uV/m.
  2. Position the dipole antenna.
  3. Adjust to read 20uV/m.




                                                       26
Drive-up Calibration Point.




                              27
Causes of Signal Leakage (1).


  80% of all leakage is caused by problems
   between the tap and entry to the house.

•Aging and environmental stress.
•Physical trauma to cables or connectors.
•Loose drop connectors.
•Inferior quality coaxial cable, passives, or connectors.
•Loose hard line connectors.




                                                            28
Causes of Signal Leakage (2).



•Improperly installed connectors.
•Cracks in the trunk and feeder cable.
•Animal chews.
•Poorly-shielded drop cable.
•Bad connectors at the tap.
•Corroded connectors.




                                         29
Causes of Signal Leakage (3).

•Customer installed equipment.
•Damaged amplifier housing or loose amplifier housing lid.
•Broken tap ports.
•Poor installation of splices and connectors.
•Poorly-shielded customer premise equipment.




                                                             30
Problems Caused by Ingress.



•Lines in pictures.
•Ghosting.
•Pay per view problems.
•High speed data problems.
•De-scrambling problems.
•Interference with two-way radio services using the
same frequencies.




                                                      31
Problems Caused by Ingress in digital channels.




        •Mosaic.
        •Freeze frame.
        •Picture and sound to black.




                                                  32
Type of Leakage Detecting Equipment.




                                       33
Accessories for the Super Plus.




 Vehicular
 Antenna
 AVM-2 108 to
 AVM-
118 MHz AVM-3
         AVM-
118 to 157 MHz
                                        Half Wave Dipole
                                       can be extended to
                                             20 feet




                                                    34
Accessories for the Super Plus.




              Half wave fixed frequency dipole   50
                       ohms impedance.
              Extends to the require 10 feet for CLI
                        measurements.
              Order frequency: 108 to 157.25 MHz.




                                                 35
Accessories for the Super Plus.




                    Near-field probe for close-in
                    detection of signal leakage.




                                             36
Accessories for the Super Plus.




The solution to “False Alarms”
Give low-frequency modulation, ignored by the TV sets, but causes a
distinctive response to TRILITHIC Searcher Plus and Super Plus.
When use it eliminates all “false alarm” triggers and increases leak
detection sensitivity by four times over previous models.


                                                                 37
Dipole Antenna Radiation Patterns.




  Pattern of the dipole antenna
installed in the roof of the truck
        doing CLI testing.




                                                 38
Finding a leak for CLI.




                          39
Finding Leakage.



Leak Tones


  DISTANCE = 10ft or less
                             SENS
  use: x10 setting
                              X1
  (remember to multiply
                              X10
  settings by 10)

                                    uV/M




                             SENS
  DISTANCE = 100ft or less
                              X1
  use: x1 setting
                              X10


                                    uV/M




  DISTANCE = 400ft or less   SENS
                              X1
  use: SENS setting
                              X10


                                    uV/M
                                           40
Leakage Measurement.



   Leak Tones




      3 metres below
      suspected leak




                3 metres above
                    ground




                                 41
Interesting web sites.


Below are web sites where you can get technical information on
CATV and HFC systems. Most of these sites are from University
                        and are free.


          http://cable.doit.wisc.edu/cable_resources.html

        http://www.itcom.itd.umich.edu/cabling/fib-glos.html

 http://whatis.techtarget.com/definitionsAlpha/0,289930,sid9,00.html




                                                                   42
Interesting web sites.
Below are web sites of all the majors CATV and FIBER
       OPTIC and COAXIAL CABLES supplier.
                   http://www.acterna.com/

                    http://www.aflfiber.com/

               http://www.alphatechnologies.com/
                   http://www.amcomm.com/
         http://www.amphenol-catv.com/catvfamsearch1.cfm

                     http://www.c-cor.net/
         http://www.commscope.com/html/home.shtml

             http://www.corning.com/OpticalFiber/
   http://www.electrolinequip.com/en/about_us/faq/index.html

            http://www.corning.com/corninggilbert/

             http://www.lindsayelec.com/lspa.html
                                                               43
Interesting web sites.

     Below are web sites of all the majors CATV and FIBER OPTIC
                  and COAXIAL CABLES supplier.

                                   http://www.gi.com/
                                 http://www.nettest.com/

http://www.ofsoptics.com/NASApp/cs/ContentServer?pagename=ofsoptics/templates/ofsopticsmain

                                http://www.powerware.ca/
                         http://www.ppc-online.com/main2.cfm
                               http://www.timesfiber.com/
                                 http://www.trilithic.com/
                               http://www.visionteq.com/
                                http://www.wavecom.ca/



                                                                                    44
45

More Related Content

What's hot

A pragmatic approach to Extended Spectrum DOCSIS: November 2020
A pragmatic approach to Extended Spectrum DOCSIS: November 2020A pragmatic approach to Extended Spectrum DOCSIS: November 2020
A pragmatic approach to Extended Spectrum DOCSIS: November 2020Teleste Corporation
 
Introduction to RF & Wireless - Part 3
Introduction to RF & Wireless - Part 3Introduction to RF & Wireless - Part 3
Introduction to RF & Wireless - Part 3Carl Weisman
 
Rf receiver design case studies
Rf receiver design case studiesRf receiver design case studies
Rf receiver design case studiesPhani Kumar
 
Extended Upstream - The heat is on!
Extended Upstream - The heat is on!Extended Upstream - The heat is on!
Extended Upstream - The heat is on!Teleste Corporation
 
Es'hail2 1er satellite radioamateur gĂŠostationnaire QATAR OSCAR-100
Es'hail2 1er satellite radioamateur gĂŠostationnaire QATAR OSCAR-100Es'hail2 1er satellite radioamateur gĂŠostationnaire QATAR OSCAR-100
Es'hail2 1er satellite radioamateur gĂŠostationnaire QATAR OSCAR-100Passion Radio Amateur
 
Drive procedure
Drive procedureDrive procedure
Drive procedureanil parmar
 
High Sensitivity Very Low Frequency Receiver for Earthquake Data Acquisition
High Sensitivity Very Low Frequency Receiver for Earthquake Data AcquisitionHigh Sensitivity Very Low Frequency Receiver for Earthquake Data Acquisition
High Sensitivity Very Low Frequency Receiver for Earthquake Data AcquisitionTELKOMNIKA JOURNAL
 
Earth Station Subsystem
Earth Station SubsystemEarth Station Subsystem
Earth Station SubsystemMadhuri Sachane
 
WCDMA Based Events
WCDMA Based EventsWCDMA Based Events
WCDMA Based EventsM Ismail Raza
 
Analysis of GSM ORFS Issue
Analysis of GSM ORFS IssueAnalysis of GSM ORFS Issue
Analysis of GSM ORFS Issuecriterion123
 
RF Transceivers
RF TransceiversRF Transceivers
RF TransceiversRitul Sonania
 
RF transmitter & receiver
RF transmitter & receiverRF transmitter & receiver
RF transmitter & receivercodexdesign
 
Pmp 36320 access_point_spec_sheet_december2011
Pmp 36320 access_point_spec_sheet_december2011Pmp 36320 access_point_spec_sheet_december2011
Pmp 36320 access_point_spec_sheet_december2011Advantec Distribution
 
Anywave Technical Seminar July 2016 OFDM ISDB-T2
Anywave Technical Seminar   July 2016 OFDM ISDB-T2Anywave Technical Seminar   July 2016 OFDM ISDB-T2
Anywave Technical Seminar July 2016 OFDM ISDB-T2Frank Massa
 

What's hot (20)

A pragmatic approach to Extended Spectrum DOCSIS: November 2020
A pragmatic approach to Extended Spectrum DOCSIS: November 2020A pragmatic approach to Extended Spectrum DOCSIS: November 2020
A pragmatic approach to Extended Spectrum DOCSIS: November 2020
 
Introduction to RF & Wireless - Part 3
Introduction to RF & Wireless - Part 3Introduction to RF & Wireless - Part 3
Introduction to RF & Wireless - Part 3
 
Rf receiver design case studies
Rf receiver design case studiesRf receiver design case studies
Rf receiver design case studies
 
Extended Upstream - The heat is on!
Extended Upstream - The heat is on!Extended Upstream - The heat is on!
Extended Upstream - The heat is on!
 
Rf optimization
Rf optimizationRf optimization
Rf optimization
 
Rf basics
Rf basicsRf basics
Rf basics
 
Es'hail2 1er satellite radioamateur gĂŠostationnaire QATAR OSCAR-100
Es'hail2 1er satellite radioamateur gĂŠostationnaire QATAR OSCAR-100Es'hail2 1er satellite radioamateur gĂŠostationnaire QATAR OSCAR-100
Es'hail2 1er satellite radioamateur gĂŠostationnaire QATAR OSCAR-100
 
Drive procedure
Drive procedureDrive procedure
Drive procedure
 
High Sensitivity Very Low Frequency Receiver for Earthquake Data Acquisition
High Sensitivity Very Low Frequency Receiver for Earthquake Data AcquisitionHigh Sensitivity Very Low Frequency Receiver for Earthquake Data Acquisition
High Sensitivity Very Low Frequency Receiver for Earthquake Data Acquisition
 
Mfc
MfcMfc
Mfc
 
Mfc
MfcMfc
Mfc
 
Earth Station Subsystem
Earth Station SubsystemEarth Station Subsystem
Earth Station Subsystem
 
WCDMA Based Events
WCDMA Based EventsWCDMA Based Events
WCDMA Based Events
 
Spaun
SpaunSpaun
Spaun
 
Analysis of GSM ORFS Issue
Analysis of GSM ORFS IssueAnalysis of GSM ORFS Issue
Analysis of GSM ORFS Issue
 
RF Transceivers
RF TransceiversRF Transceivers
RF Transceivers
 
Work microwave
Work microwaveWork microwave
Work microwave
 
RF transmitter & receiver
RF transmitter & receiverRF transmitter & receiver
RF transmitter & receiver
 
Pmp 36320 access_point_spec_sheet_december2011
Pmp 36320 access_point_spec_sheet_december2011Pmp 36320 access_point_spec_sheet_december2011
Pmp 36320 access_point_spec_sheet_december2011
 
Anywave Technical Seminar July 2016 OFDM ISDB-T2
Anywave Technical Seminar   July 2016 OFDM ISDB-T2Anywave Technical Seminar   July 2016 OFDM ISDB-T2
Anywave Technical Seminar July 2016 OFDM ISDB-T2
 

Viewers also liked

Festas do San XoĂĄn
Festas do San XoĂĄnFestas do San XoĂĄn
Festas do San XoĂĄnnoagaliza
 
Presentacion geocondamuĂąoz
Presentacion geocondamuĂąozPresentacion geocondamuĂąoz
Presentacion geocondamuĂąozYOGISS MuĂąoz
 
Su
SuSu
Suasd
 
Inria - leaflet of research centre Rennes - Bretagne Atlantique
Inria - leaflet of research centre Rennes - Bretagne AtlantiqueInria - leaflet of research centre Rennes - Bretagne Atlantique
Inria - leaflet of research centre Rennes - Bretagne AtlantiqueInria
 
Magen 2012
Magen 2012Magen 2012
Magen 2012rvas
 
Vocabulary Body
Vocabulary BodyVocabulary Body
Vocabulary Bodyluciamontoliu
 
FabMarker for IT Park
FabMarker for IT ParkFabMarker for IT Park
FabMarker for IT ParkPaul Serikov
 
Lina Sagrado
Lina SagradoLina Sagrado
Lina Sagradoguest29caee
 
Lighting
LightingLighting
Lightingkellipt
 
Full Prism Solution Overview
Full Prism Solution OverviewFull Prism Solution Overview
Full Prism Solution OverviewAndrew Bain
 
Gee Ukase
Gee UkaseGee Ukase
Gee Ukaserix
 
Партнерство на рынке недвижимости: миф или реальность
Партнерство на рынке недвижимости: миф или реальностьПартнерство на рынке недвижимости: миф или реальность
Партнерство на рынке недвижимости: миф или реальностьSalesDog
 
世界美景106幅
世界美景106幅世界美景106幅
世界美景106幅英
 
Test
TestTest
TestBizquit
 
CIS 512-Week 4 Presentation
CIS 512-Week 4 PresentationCIS 512-Week 4 Presentation
CIS 512-Week 4 PresentationNFCU
 
Bct Terms 1 3
Bct Terms 1 3Bct Terms 1 3
Bct Terms 1 306yuqingchen
 

Viewers also liked (20)

Festas do San XoĂĄn
Festas do San XoĂĄnFestas do San XoĂĄn
Festas do San XoĂĄn
 
Presentacion geocondamuĂąoz
Presentacion geocondamuĂąozPresentacion geocondamuĂąoz
Presentacion geocondamuĂąoz
 
Su
SuSu
Su
 
Combustion
CombustionCombustion
Combustion
 
Hfc c he example of hfc
Hfc c he example of hfcHfc c he example of hfc
Hfc c he example of hfc
 
Hfc q- more on docsis
Hfc q- more on docsisHfc q- more on docsis
Hfc q- more on docsis
 
Inria - leaflet of research centre Rennes - Bretagne Atlantique
Inria - leaflet of research centre Rennes - Bretagne AtlantiqueInria - leaflet of research centre Rennes - Bretagne Atlantique
Inria - leaflet of research centre Rennes - Bretagne Atlantique
 
Magen 2012
Magen 2012Magen 2012
Magen 2012
 
Vocabulary Body
Vocabulary BodyVocabulary Body
Vocabulary Body
 
FabMarker for IT Park
FabMarker for IT ParkFabMarker for IT Park
FabMarker for IT Park
 
Hfc j system distortion calculation
Hfc j system distortion calculationHfc j system distortion calculation
Hfc j system distortion calculation
 
Lina Sagrado
Lina SagradoLina Sagrado
Lina Sagrado
 
Lighting
LightingLighting
Lighting
 
Full Prism Solution Overview
Full Prism Solution OverviewFull Prism Solution Overview
Full Prism Solution Overview
 
Gee Ukase
Gee UkaseGee Ukase
Gee Ukase
 
Партнерство на рынке недвижимости: миф или реальность
Партнерство на рынке недвижимости: миф или реальностьПартнерство на рынке недвижимости: миф или реальность
Партнерство на рынке недвижимости: миф или реальность
 
世界美景106幅
世界美景106幅世界美景106幅
世界美景106幅
 
Test
TestTest
Test
 
CIS 512-Week 4 Presentation
CIS 512-Week 4 PresentationCIS 512-Week 4 Presentation
CIS 512-Week 4 Presentation
 
Bct Terms 1 3
Bct Terms 1 3Bct Terms 1 3
Bct Terms 1 3
 

Similar to Hfc o cli seminar

Ca code and its properties
Ca code and its propertiesCa code and its properties
Ca code and its propertiesKSINDHU6
 
Microwave Radiometer Analysis for Imaging and Vehicular Systems
Microwave Radiometer Analysis for Imaging and Vehicular SystemsMicrowave Radiometer Analysis for Imaging and Vehicular Systems
Microwave Radiometer Analysis for Imaging and Vehicular SystemsIRJET Journal
 
California Firecodes
California FirecodesCalifornia Firecodes
California Firecodesmalcolmfd
 
Volume 2-issue-6-1965-1968
Volume 2-issue-6-1965-1968Volume 2-issue-6-1965-1968
Volume 2-issue-6-1965-1968Editor IJARCET
 
Volume 2-issue-6-1965-1968
Volume 2-issue-6-1965-1968Volume 2-issue-6-1965-1968
Volume 2-issue-6-1965-1968Editor IJARCET
 
transmission_line_protection.ppt
transmission_line_protection.ppttransmission_line_protection.ppt
transmission_line_protection.pptAmitBiswas596731
 
Signal Leakage and Ingress at Higher Frequencies, Understanding the Challenge...
Signal Leakage and Ingress at Higher Frequencies, Understanding the Challenge...Signal Leakage and Ingress at Higher Frequencies, Understanding the Challenge...
Signal Leakage and Ingress at Higher Frequencies, Understanding the Challenge...Cisco Service Provider
 
transmission-line-protection.ppt
transmission-line-protection.ppttransmission-line-protection.ppt
transmission-line-protection.pptssuser0132001
 
Drive test golden rules
Drive test golden rulesDrive test golden rules
Drive test golden rulesFidele Castro
 
Huawei_MIMO_solution.pdf
Huawei_MIMO_solution.pdfHuawei_MIMO_solution.pdf
Huawei_MIMO_solution.pdfssuser32515c
 
Implementation and Validation of K Line (ISO 9141) Protocol for Diagnostic Ap...
Implementation and Validation of K Line (ISO 9141) Protocol for Diagnostic Ap...Implementation and Validation of K Line (ISO 9141) Protocol for Diagnostic Ap...
Implementation and Validation of K Line (ISO 9141) Protocol for Diagnostic Ap...IRJET Journal
 

Similar to Hfc o cli seminar (20)

Ca code and its properties
Ca code and its propertiesCa code and its properties
Ca code and its properties
 
Grid stds
Grid stdsGrid stds
Grid stds
 
Microwave Radiometer Analysis for Imaging and Vehicular Systems
Microwave Radiometer Analysis for Imaging and Vehicular SystemsMicrowave Radiometer Analysis for Imaging and Vehicular Systems
Microwave Radiometer Analysis for Imaging and Vehicular Systems
 
MIL-STD-461G - CE
MIL-STD-461G - CEMIL-STD-461G - CE
MIL-STD-461G - CE
 
MIL-STD-461G - CS
MIL-STD-461G - CSMIL-STD-461G - CS
MIL-STD-461G - CS
 
California Firecodes
California FirecodesCalifornia Firecodes
California Firecodes
 
Volume 2-issue-6-1965-1968
Volume 2-issue-6-1965-1968Volume 2-issue-6-1965-1968
Volume 2-issue-6-1965-1968
 
Volume 2-issue-6-1965-1968
Volume 2-issue-6-1965-1968Volume 2-issue-6-1965-1968
Volume 2-issue-6-1965-1968
 
Ijetcas14 396
Ijetcas14 396Ijetcas14 396
Ijetcas14 396
 
B1102030610
B1102030610B1102030610
B1102030610
 
An 1109
An 1109An 1109
An 1109
 
transmission_line_protection.ppt
transmission_line_protection.ppttransmission_line_protection.ppt
transmission_line_protection.ppt
 
Vusi
VusiVusi
Vusi
 
Signal Leakage and Ingress at Higher Frequencies, Understanding the Challenge...
Signal Leakage and Ingress at Higher Frequencies, Understanding the Challenge...Signal Leakage and Ingress at Higher Frequencies, Understanding the Challenge...
Signal Leakage and Ingress at Higher Frequencies, Understanding the Challenge...
 
ppt
pptppt
ppt
 
transmission-line-protection.ppt
transmission-line-protection.ppttransmission-line-protection.ppt
transmission-line-protection.ppt
 
Drive test golden rules
Drive test golden rulesDrive test golden rules
Drive test golden rules
 
Huawei_MIMO_solution.pdf
Huawei_MIMO_solution.pdfHuawei_MIMO_solution.pdf
Huawei_MIMO_solution.pdf
 
MIL-STD-461G - CS
MIL-STD-461G - CSMIL-STD-461G - CS
MIL-STD-461G - CS
 
Implementation and Validation of K Line (ISO 9141) Protocol for Diagnostic Ap...
Implementation and Validation of K Line (ISO 9141) Protocol for Diagnostic Ap...Implementation and Validation of K Line (ISO 9141) Protocol for Diagnostic Ap...
Implementation and Validation of K Line (ISO 9141) Protocol for Diagnostic Ap...
 

More from jose angel guzman lozano

More from jose angel guzman lozano (8)

Cabecera
CabeceraCabecera
Cabecera
 
Capacitacion+Atenuador++Mezclador
Capacitacion+Atenuador++MezcladorCapacitacion+Atenuador++Mezclador
Capacitacion+Atenuador++Mezclador
 
Hfc l alignment and system maintenance
Hfc l alignment and system maintenanceHfc l alignment and system maintenance
Hfc l alignment and system maintenance
 
Hfc i fiber management
Hfc i fiber managementHfc i fiber management
Hfc i fiber management
 
Hfc h fiber optic testing
Hfc h fiber optic testingHfc h fiber optic testing
Hfc h fiber optic testing
 
Hfc g rf amplifiers
Hfc g rf amplifiersHfc g rf amplifiers
Hfc g rf amplifiers
 
Hfc f outside plan
Hfc f outside planHfc f outside plan
Hfc f outside plan
 
Hfc d coaxial fiber optic
Hfc d coaxial fiber opticHfc d coaxial fiber optic
Hfc d coaxial fiber optic
 

Recently uploaded

Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsJoaquim Jorge
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityPrincipled Technologies
 
🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘RTylerCroy
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptxHampshireHUG
 
presentation ICT roal in 21st century education
presentation ICT roal in 21st century educationpresentation ICT roal in 21st century education
presentation ICT roal in 21st century educationjfdjdjcjdnsjd
 
Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024The Digital Insurer
 
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdfUnderstanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdfUK Journal
 
GenAI Risks & Security Meetup 01052024.pdf
GenAI Risks & Security Meetup 01052024.pdfGenAI Risks & Security Meetup 01052024.pdf
GenAI Risks & Security Meetup 01052024.pdflior mazor
 
Strategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a FresherStrategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a FresherRemote DBA Services
 
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, AdobeApidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobeapidays
 
Partners Life - Insurer Innovation Award 2024
Partners Life - Insurer Innovation Award 2024Partners Life - Insurer Innovation Award 2024
Partners Life - Insurer Innovation Award 2024The Digital Insurer
 
Tech Trends Report 2024 Future Today Institute.pdf
Tech Trends Report 2024 Future Today Institute.pdfTech Trends Report 2024 Future Today Institute.pdf
Tech Trends Report 2024 Future Today Institute.pdfhans926745
 
[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdfhans926745
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024The Digital Insurer
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAndrey Devyatkin
 
Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024The Digital Insurer
 
Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Enterprise Knowledge
 
What Are The Drone Anti-jamming Systems Technology?
What Are The Drone Anti-jamming Systems Technology?What Are The Drone Anti-jamming Systems Technology?
What Are The Drone Anti-jamming Systems Technology?Antenna Manufacturer Coco
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationRadu Cotescu
 
Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...apidays
 

Recently uploaded (20)

Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and Myths
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivity
 
🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
 
presentation ICT roal in 21st century education
presentation ICT roal in 21st century educationpresentation ICT roal in 21st century education
presentation ICT roal in 21st century education
 
Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024
 
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdfUnderstanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
 
GenAI Risks & Security Meetup 01052024.pdf
GenAI Risks & Security Meetup 01052024.pdfGenAI Risks & Security Meetup 01052024.pdf
GenAI Risks & Security Meetup 01052024.pdf
 
Strategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a FresherStrategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a Fresher
 
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, AdobeApidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
 
Partners Life - Insurer Innovation Award 2024
Partners Life - Insurer Innovation Award 2024Partners Life - Insurer Innovation Award 2024
Partners Life - Insurer Innovation Award 2024
 
Tech Trends Report 2024 Future Today Institute.pdf
Tech Trends Report 2024 Future Today Institute.pdfTech Trends Report 2024 Future Today Institute.pdf
Tech Trends Report 2024 Future Today Institute.pdf
 
[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of Terraform
 
Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024
 
Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...
 
What Are The Drone Anti-jamming Systems Technology?
What Are The Drone Anti-jamming Systems Technology?What Are The Drone Anti-jamming Systems Technology?
What Are The Drone Anti-jamming Systems Technology?
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organization
 
Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...
 

Hfc o cli seminar

  • 1. Broadband System – O Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz "L" Band Toward earth 4.0 GHz Toward satellite 14.0 GHz Toward earth 12.0 GHz TV TRANSMITTER Headend Cable area 1 CLI Cumulative Leakage Index
  • 3. Leakage Terminology •Radiation. •Egress •Ingress •Leakage •uV M (Micro volts per Meter) •CLI (Cumulative Leakage Index) 3
  • 4. Ingress / Egress Ingress: RF signal leaking into the coaxial plant. Egress: RF signal leaking out of the coaxial plant. 4
  • 5. Reasons to monitor leakage 1. Prevent Off-Air Broadcast Interference. 2. To meet government compliance. 3. To give our customer better quality of signal. 5
  • 6. Spectrum Charts 108 MHz. 118 MHz 137 MHz Off-Air Air navigation Air voice communications Cable Ch: 98 - 99 Ch: 14 - 15 - 16 144 MHz. 162 MHz 174 MHz Off-Air Ham Operators Government mobile Cable Ch: 18 - 19 - 20 - 21 - 22 6
  • 7. Spectrum Charts 225 MHz. 400 MHz. Off-Air Military Air voice communication Cable Ch: See below. •155.34 MHz - Nationwide Hospital / Ambulance Radio Link •156.80 MHz - Marine Emergency Aircraft Survival Locator. •243.00 MHz - Emergency Aircraft Survival Locator. 7
  • 8. Signal Leakage History • Mid-band expansion. • Aeronautical interference discover (1976) • Frequency offsets (1979) • Radian dome (1980) • Mandatory FCC / DOC enforcement (1980s) • Cumulative Leakage Index (1990) 8
  • 9. Cumulative Leakage Index CLI CLI is the net effect of the combination of all the leaks in the system added together. These cumulative leaks form an invisible cloud of unwanted RF energy over the cable system. 9
  • 10. CLI Rules (Quarterly) •Ride out 100% of system and log all leaks. •Log should include Date found and Date fixed. •Documenting leakage level isn't required for this drive out. •Actual practice for your system may vary! 10
  • 11. CLI Rules (Annually) •Ride out 75% of the oldest part of the system and log all leaks location and measured level. •Must be performed within a reasonable period of time (Usually within 2 wks of due date) •Actual practice for your system may vary! 11
  • 12. The only acceptable procedure for leakage measurement by the government rule. •Use a calibrated half wave dipole antenna. •Antenna must be elevated 3 meters off the ground and positioned 3 meters from the leakage source. •Antenna must be rotated 360° in the horizontal plane for maximum reading. 12
  • 13. Required actions. •All leaks above 20uV/m must be logged and fixed. •Only leaks above 50uV/m are used in CLI calculation. •All measurements taken outside 108 – 137 MHz must be converted as if they were taken within the band. 13
  • 14. uV/M (Microvolts per Metre) •Standard unit of measure for CLI •50 Ohm off air measurement. •Voltage developed in 1 meter of infinitely, this section of wire submerged in a leakage field produces 1uV of energy. 14
  • 15. C.L.I. •Cumulative Leakage Index. •Mathematical summation of leakage in a system designed to approximate the interference to aircraft flying overhead. •Figure of merit for system performance. •One leak of 1588uV/M within a system is enough to fail C.L.I. 15
  • 16. Cumulative Leakage Index. 10XLOG ( Total Plant ) X ( sum of Leak²) Miles Driven Compliance = 64 leaks or less. 16
  • 17. BP-23 for Canadian Operator. 3.2 Leakage Control 3.2.1 At all times, cable system operators should strive to minimized emanating from their facilities. 3.2.2 The operator of a cable television system distributing signals over supplementary channels must carry out a systematic patrols to detect leakage, and take corrective measures to prevent leakage. 3.2.3 The operator of a cable television system must keep a logbook indicating the date and location foe each leak detected, the date on which it was repaired and its probable cause. This logbook must be kept for a period of two years so that it may be examined by an inspector from the Department upon request. 3.2.4 When leakage originates from a subscriber’s premises, the system operator must ensure the necessary repairs are carried out. If such repairs cannot be effected within a reasonable period of time, the operator must stop distribution of the interfering service(s) or channel(s) to the subscriber’s premises until the leakage can be repaired. In addition, distribution of interfering of service(s) or channel(s) to subscriber’s premises must be stopped immediately if the leakage originating from the subscriber endanger safety services (ambulance, police, aeronautical frequencies, and so on) 17
  • 18. BP-23 for Canadian Operator. 4.1 General Provisions 4.11 Unless indicated otherwise, all technical standards stated herein apply to the requirements respecting performance between the cable television system input and any subscriber terminal. 4.1.2 All technical standards specified herein relate to the measurement procedure discussed in this document, and, where appropriate, apply in the presence of all signals usually carried on the system. 4.2 Leakage Criteria 4.2.1 The following leakage criteria are used to evaluate cable system leakage performance. 4.2.2 The Equivalent Leakage Density estimates the impact of signal leakage on land-based radio system- I.e. police, ambulance service, etc.- which share spectrum with cable television systems. The ELD criterion ensures that all cable systems meet a leakage performance intended to minimize interference to land-radio system. 4.2.3 The Cumulative Leakage Index (CLI) estimates the cumulative impact of leakage on aeronautical spectrum users. When the signal leakage measurements are taken on the ground, the CLI ground-based criterion (CLIg) is used. If the measurements are taken in the airspace above the cable system, the CLI air-based criterion (CLIa) is used to estimate this impact. Both criteria apply to cable system carrying A-1(99), A-2(98), EE941) and FF(42) 18
  • 19. BP-23 for Canadian Operator. http://strategis.ic.gc.ca/epic/internet/insmt-gst.nsf/vwapj/bpr8e.pdf/$FILE/bpr8e.pdf You can get this procedure at the above internet link 19
  • 20. BP-23 for Canadian Operator. 4.3 Equivalent Leakage Density (ELD) For the purposes of calculating the Equivalent Leakage Density, leakage readings are classified into three categories, each of which has it corresponding weighting factor, as shown in the table below. 20
  • 21. BP-23 for Canadian Operator. 4.3.2 The ELD is calculated using the following formula: ELD = (N1 X 1) + (N2 X 2) + N3 X 3), K where: ELD = Equivalent Leakage Density N1 = Number of leaks in Category A (50 – 220 uV/m) N2 = Number of leaks in Category B (201 – 500 uV/m) N3 = Number of leaks in Category C (>500 uV/m) 1 = Category A weighting factor 2 = Category B weighting factor 3 = Category C weighting factor K = Number of kilometres patrolled. 4.3.3 For the purposes of ELD calculations, only leaks equal to or grater than 50 uV/ at 3 metres need to be taken into account. 21
  • 22. BP-23 for Canadian Operator. 4.4 Equivalent Leakage Density Application Schedule. Table 4.2 shows the ELD limits applications schedule. The beginning of the first implementation period coincides with the effective date of this document. Cable systems will have to the end of each implementation period to reach the ELD limit that applies for that period. The maximum limit after 6 years is 0.8. 22
  • 23. BP-23 for Canadian Operator. 4.5 CLI Ground-Based Criterion (CLIg) 4.5.1 The computed CLIg must not be over 64. 4.5.2 The CLIg is calculated using the following formulas: Where: CLIg = CLI ground-based criterion, taking into the surface area of the system F(S) = Correction factor for the surface area Ei = Filed strength of the ith leak measured at 3 metres, in uV/m S = Surface area covered by the cable system in km² N = Number of leaks detected 4.5.3 While all leaks, regardless of magnitude, must be repaired, it is not necessary to take into account leaks of less than 50 uV/m at 3 metres when calculating the CLIg 23
  • 24. BP-23 for Canadian Operator. 4.6 CLI Air-Based criterion (CLIa) The CLIa is the 90th-percentile value of the field strength due to cable leaks and it must not exceed 10 microvolts per metre RMS at an altitude of 450 metres above the cable system’s average ground level. 4.7 Carrier-to-Noise ratio The carrier-to-noise ration for each television channel received at any subscriber terminal must not be less than 40 dB. The full BP-23 can be downloaded at the internet address below: http://strategis.ic.gc.ca/SSG/sf01209e.html 24
  • 25. Patrolling for Leakage 20uV/m 10 feet 100 feet 2 uV/m 25
  • 26. Calibrating Leakage Detection Equipment. 1. Connect calibrated signal source set at 20uV/m. 2. Position the dipole antenna. 3. Adjust to read 20uV/m. 26
  • 28. Causes of Signal Leakage (1). 80% of all leakage is caused by problems between the tap and entry to the house. •Aging and environmental stress. •Physical trauma to cables or connectors. •Loose drop connectors. •Inferior quality coaxial cable, passives, or connectors. •Loose hard line connectors. 28
  • 29. Causes of Signal Leakage (2). •Improperly installed connectors. •Cracks in the trunk and feeder cable. •Animal chews. •Poorly-shielded drop cable. •Bad connectors at the tap. •Corroded connectors. 29
  • 30. Causes of Signal Leakage (3). •Customer installed equipment. •Damaged amplifier housing or loose amplifier housing lid. •Broken tap ports. •Poor installation of splices and connectors. •Poorly-shielded customer premise equipment. 30
  • 31. Problems Caused by Ingress. •Lines in pictures. •Ghosting. •Pay per view problems. •High speed data problems. •De-scrambling problems. •Interference with two-way radio services using the same frequencies. 31
  • 32. Problems Caused by Ingress in digital channels. •Mosaic. •Freeze frame. •Picture and sound to black. 32
  • 33. Type of Leakage Detecting Equipment. 33
  • 34. Accessories for the Super Plus. Vehicular Antenna AVM-2 108 to AVM- 118 MHz AVM-3 AVM- 118 to 157 MHz Half Wave Dipole can be extended to 20 feet 34
  • 35. Accessories for the Super Plus. Half wave fixed frequency dipole 50 ohms impedance. Extends to the require 10 feet for CLI measurements. Order frequency: 108 to 157.25 MHz. 35
  • 36. Accessories for the Super Plus. Near-field probe for close-in detection of signal leakage. 36
  • 37. Accessories for the Super Plus. The solution to “False Alarms” Give low-frequency modulation, ignored by the TV sets, but causes a distinctive response to TRILITHIC Searcher Plus and Super Plus. When use it eliminates all “false alarm” triggers and increases leak detection sensitivity by four times over previous models. 37
  • 38. Dipole Antenna Radiation Patterns. Pattern of the dipole antenna installed in the roof of the truck doing CLI testing. 38
  • 39. Finding a leak for CLI. 39
  • 40. Finding Leakage. Leak Tones DISTANCE = 10ft or less SENS use: x10 setting X1 (remember to multiply X10 settings by 10) uV/M SENS DISTANCE = 100ft or less X1 use: x1 setting X10 uV/M DISTANCE = 400ft or less SENS X1 use: SENS setting X10 uV/M 40
  • 41. Leakage Measurement. Leak Tones 3 metres below suspected leak 3 metres above ground 41
  • 42. Interesting web sites. Below are web sites where you can get technical information on CATV and HFC systems. Most of these sites are from University and are free. http://cable.doit.wisc.edu/cable_resources.html http://www.itcom.itd.umich.edu/cabling/fib-glos.html http://whatis.techtarget.com/definitionsAlpha/0,289930,sid9,00.html 42
  • 43. Interesting web sites. Below are web sites of all the majors CATV and FIBER OPTIC and COAXIAL CABLES supplier. http://www.acterna.com/ http://www.aflfiber.com/ http://www.alphatechnologies.com/ http://www.amcomm.com/ http://www.amphenol-catv.com/catvfamsearch1.cfm http://www.c-cor.net/ http://www.commscope.com/html/home.shtml http://www.corning.com/OpticalFiber/ http://www.electrolinequip.com/en/about_us/faq/index.html http://www.corning.com/corninggilbert/ http://www.lindsayelec.com/lspa.html 43
  • 44. Interesting web sites. Below are web sites of all the majors CATV and FIBER OPTIC and COAXIAL CABLES supplier. http://www.gi.com/ http://www.nettest.com/ http://www.ofsoptics.com/NASApp/cs/ContentServer?pagename=ofsoptics/templates/ofsopticsmain http://www.powerware.ca/ http://www.ppc-online.com/main2.cfm http://www.timesfiber.com/ http://www.trilithic.com/ http://www.visionteq.com/ http://www.wavecom.ca/ 44
  • 45. 45