10KVA GENSET Powered by PERKINS Diesel Engine Model 403A-11G1, 03 Cylinders, 1500 RPM & LINZ ALTERNATOR, 50HZ, 3 Phase, 400 Volts, Equipped with DEEPSEA Control Panel.

3 PHASE OUTPUTS
GENERATOR SET MODEL RATING 50HZ 60HZ
380-415 V, 1500 rpm 480 V, 1800 rpm
KVA KW KVA KW
PM-09C
PRIME 9 7.2 - -
STAND-BY 10 8 - -
ENGINE / TECHNICAL DATA
Engine Make Perkins
Engine Model 403D-11G
Governing Type Mechanical
Cylinder Arrangement Vertical in line
Number of Cylinders 3
Bore and Stroke 77 x 81
Displacement/Cubic Capacity liters 1.131
Induction System Naturally Aspirated
Cycle 4 stroke
Combustion System Indirect Injection
Compression Ratio 23:1
Rotation Anti-clockwise (viewed from flywheel)
Cooling System Water-cooled
Frequency and Engine Speed 50Hz & 1500rpm
Prime Standby
Gross Engine Power kW (hp) 8.6 (11.5) 9.5 (12.7)
FUEL CONSUMPTION (L/H) 50%
75%
100%
1.7 -
2.3 -
3.0 3.6
Total Lubrication System Capacity [liters] 4.9 4.9
Total Coolant Capacity (inc. radiator) [ltrs] 5.2 5.2
Exhaust Temperature o
C 445 490
Radiator Cooling Air Flow (Min): m3
/sec 0.06 0.06
Combustion Air Flow: m3
/sec 1.1 1.1
Exhaust Gas Flow: m3
/sec 1.8 1.8
Fuel Tank Capacity 43 43
ALTERNATOR DATA
Make Leroy Somer
Model TAL 040B
No. of bearings 1
Insulation Class H
Total Harmonic
Content
at no load <3.5 %
-on load <5%
Wires 6
Ingress
Protection
IP23
Excitation
System
SHUNT
Winding Pitch 2/3 (wdg3)
AVR Model R120
Overspeed 2250 mn-1
Voltage
Regulation
+ 1%
CONTROL PANEL
Make Deepsea
Model DSE4610
This Auto Start Control Module
(DSE4610) has been designed and
built to combine all the instruments
control and the warning lights for
engine and alternator. The sheet
steel made panel is carefully
painted for tropical climates and is
designed for a dusty environment.
Includes following equipment:
- Ammeter with selector switch
- Water temperature meter
- oil pressure meter
- molded case three pole circuit
breakers with thermal and magnetic
release
- automatic shut down in case of
HWT, LOP and over speed
- starting key and stop push button
- acoustical signal - warning light
for high cooling water temperature,
low oil pressure, battery charging
- hours meter
Dimension and Weight
DIMENSION OPEN SILENT
Length (L) 1150 mm 1910 mm
Width (W) 520 mm 860 mm
Height (H) 1320 mm 1265 mm
Net Weight 300 kg 742 kg
Generating Sets
POWERED BY:
*Ratings at 0.8 pf - Generator designed to operate in ambient temperatures up to 52 o
C
*Generating Set photo is for reference only.
PM9
9. MOUNTING ARRANGEMENT
9.1 BASE FRAME
The complete generating set is mounted on heavy duty
steel fabricated base frame Which is anti rust coated.
9.2 COUPLING
Engine and alternator are directly coupled by means of
SAE flange so there is no possibility of misalignment
after prolong use. The engine fly wheel is flexibly
coupled to the alternator rotor.
9.3 ANTI VIBRATION MOUNTING PADS
Anti vibration pads are fitted between engine-alternator
base frame ensuring complete vibration isolation of
rotating assemblies.
10. FUEL SYSTEM
Metal Fuel tank of 180 litres capacity. The Fuel tank is
easy to clean and is equipped with visual fuel level
indicator.
11. DOCUMENTATION
A full set of operation and maintenance manual are
provided.
12. FACTORY TESTS
Generating set is subject to a strict load test before
delivery. A test certificate can be provided as optional.
13. QUALITY STANDARDS
Generating set meets the following standards ISO 8528,
IEC 34.1, CEI 2.3, VDE 0530, BS 4999-5000, NF51-
100. Perkins is fully accredited ISO 9001 company.
14. WARRANTY
Generating set is guaranteed for a period of 12 months
from date of commissioning or18 months from date of
shipment which ever occurs earlier. (check warranty statement
for more details, as it may vary for different countries)
In line with our policy of continuous product development, we reserve right
to change specification without notice
.
RATING DEFINITIONS:
Prime Power - These ratings are applicable for supplying continuous power (at variable load) in lieu of commercially purchased
power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Standby Power - These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility
power failure. No overload is permitted on these rating. When used at standby Rating the alternator will be peak continuous rated
(according to ISO3046)
Generating Sets
PM9
1. ENGINE
Perkins heavy duty diesel engine.
1.1 GOVERNOR
Mechanical, compliance with ISO8528, Class G2.
2. COOLING RADIATOR
Radiator and cooling fan complete with protection guards,
designed to cool the engine in ambient temperatures up to
52° C. The radiator is mounted on the base frame to avoid
vibrations coming from the engine.
3. FILTRATION SYSTEM
Cartridge type air filter with security element. Cartridge fuel
filter and full lube oil filter. All filters have replaceable
elements.
4. EXHAUST SYSTEM
Heavy-duty industrial silencer.
5. ELECTRICAL SYSTEM
12 Volt system with battery charging alternator, Starter
motor, High capacity maintenance free lead acid battery,
battery rack mounted on the generating set base frame,
and heavy duty interconnecting cables with terminations.
6. ALTERNATOR
Screen protected and drip-proof, self-exciting, self-
regulating brush-less alternator. Four poles, STAR
winding connection, suitable for tropical, humid and saline
climates. H class insulation.
7. AUTOMATIC VOLTAGE REGULATOR (AVR)
Static electronic design voltage regulator. Steady voltage
precision within + 1 % from no load to full load including
cold and hot variations, at any Power factor between 0.8
and unity.
8. MOTOR STARTING
An overload capacity equivalent to between 160% to 300%
(depending on alternator frame size) of full load
impedance at zero power factor can be sustained for 10
seconds.
T: +971 4 8833456
F: +971 4 8833458
Warehouse No RA08 XA-04
P. O. Box 17305 Jebel Ali, Dubai, UAE
www.adpower.ae
sales@adpower.ae
STANDARD REFERENCE CONDITIONS
Output ratings are presented at 27o
C air Inlet temperature, 1000 m
bar and 30% relative humidity. Fuel consumption data at various
loads, diesel fuel with a specific gravity of 0.85kG/L. De-ration may
apply, please consult your dealer for specific site ratings.
Some of the specifications are not standard on all Genset Models.
Distributed and Serviced by:
STANDARD SPECIFICATIONS
AVAILABLE OPTIONS & ACCESSORIES
We offer a range of optional features and accessories to tailor our generating sets to meet your needs.
OPTIONS
• Generator Set control and synchronizing panels
• Additional Protection alarms and shutdowns
• Water fuel separator
• Water jacket heater
• Battery charger
ACCESSORIES
• Genuine spare parts
• Fuel Tanks
• Manual and Automatic Transfer Switches

Más contenido relacionado

Was ist angesagt?(9)

3 endurance 3120-brochure3 endurance 3120-brochure
3 endurance 3120-brochure
Hanan E. Levy759 views
6 bta5.9 g2(英文版)6 bta5.9 g2(英文版)
6 bta5.9 g2(英文版)
SUNSHINE MACHINERY 242 views
1006 tag1006 tag
1006 tag
SUNSHINE MACHINERY 237 views
6 bt5.9 g1(英文版)6 bt5.9 g1(英文版)
6 bt5.9 g1(英文版)
SUNSHINE MACHINERY 440 views
60 sp56360 sp563
60 sp563
SUNSHINE MACHINERY 188 views
Kpc master-catalog-parts-v1-08-27-12Kpc master-catalog-parts-v1-08-27-12
Kpc master-catalog-parts-v1-08-27-12
Alvaro Escobar2.1K views
60 sp92860 sp928
60 sp928
SUNSHINE MACHINERY 218 views

Similar a Perkins 10KVA Engine Model 403A-11G1(20)

1500REOZM_8_12b1500REOZM_8_12b
1500REOZM_8_12b
Maman Apriliano111 views
1250REOZM_8_12b1250REOZM_8_12b
1250REOZM_8_12b
Maman Apriliano95 views
2000REOZM_8_12b (1)2000REOZM_8_12b (1)
2000REOZM_8_12b (1)
Maman Apriliano136 views
1600REOZM_8_12b1600REOZM_8_12b
1600REOZM_8_12b
Maman Apriliano132 views
G5371G5371
G5371
John Paul Cañon370 views
Avp694 6 compressedAvp694 6 compressed
Avp694 6 compressed
jhonnyarpi103 views
F1013R 10-15-20L jacketed systemsF1013R 10-15-20L jacketed systems
F1013R 10-15-20L jacketed systems
Stephen Martinelli20 views
1800REOZM_8_12b1800REOZM_8_12b
1800REOZM_8_12b
Maman Apriliano101 views
1103A-33TG1 ElectropaK (PN1781 75th).pdf1103A-33TG1 ElectropaK (PN1781 75th).pdf
1103A-33TG1 ElectropaK (PN1781 75th).pdf
AbdulKhaliq8419747 views
PMSM.pdfPMSM.pdf
PMSM.pdf
NguyenTruong14953548 views
F1018R Protean Fusion ReactorF1018R Protean Fusion Reactor
F1018R Protean Fusion Reactor
Stephen Martinelli44 views
01.C2000D5-DS48-CPGK.pdf01.C2000D5-DS48-CPGK.pdf
01.C2000D5-DS48-CPGK.pdf
PhamDucTuan231 views
1000REOZM1000REOZM
1000REOZM
Maman Apriliano180 views
Tp165 tTp165 t
Tp165 t
RJAYVENTURILLO124 views

Último(20)

Perkins 10KVA Engine Model 403A-11G1

  • 1. 3 PHASE OUTPUTS GENERATOR SET MODEL RATING 50HZ 60HZ 380-415 V, 1500 rpm 480 V, 1800 rpm KVA KW KVA KW PM-09C PRIME 9 7.2 - - STAND-BY 10 8 - - ENGINE / TECHNICAL DATA Engine Make Perkins Engine Model 403D-11G Governing Type Mechanical Cylinder Arrangement Vertical in line Number of Cylinders 3 Bore and Stroke 77 x 81 Displacement/Cubic Capacity liters 1.131 Induction System Naturally Aspirated Cycle 4 stroke Combustion System Indirect Injection Compression Ratio 23:1 Rotation Anti-clockwise (viewed from flywheel) Cooling System Water-cooled Frequency and Engine Speed 50Hz & 1500rpm Prime Standby Gross Engine Power kW (hp) 8.6 (11.5) 9.5 (12.7) FUEL CONSUMPTION (L/H) 50% 75% 100% 1.7 - 2.3 - 3.0 3.6 Total Lubrication System Capacity [liters] 4.9 4.9 Total Coolant Capacity (inc. radiator) [ltrs] 5.2 5.2 Exhaust Temperature o C 445 490 Radiator Cooling Air Flow (Min): m3 /sec 0.06 0.06 Combustion Air Flow: m3 /sec 1.1 1.1 Exhaust Gas Flow: m3 /sec 1.8 1.8 Fuel Tank Capacity 43 43 ALTERNATOR DATA Make Leroy Somer Model TAL 040B No. of bearings 1 Insulation Class H Total Harmonic Content at no load <3.5 % -on load <5% Wires 6 Ingress Protection IP23 Excitation System SHUNT Winding Pitch 2/3 (wdg3) AVR Model R120 Overspeed 2250 mn-1 Voltage Regulation + 1% CONTROL PANEL Make Deepsea Model DSE4610 This Auto Start Control Module (DSE4610) has been designed and built to combine all the instruments control and the warning lights for engine and alternator. The sheet steel made panel is carefully painted for tropical climates and is designed for a dusty environment. Includes following equipment: - Ammeter with selector switch - Water temperature meter - oil pressure meter - molded case three pole circuit breakers with thermal and magnetic release - automatic shut down in case of HWT, LOP and over speed - starting key and stop push button - acoustical signal - warning light for high cooling water temperature, low oil pressure, battery charging - hours meter Dimension and Weight DIMENSION OPEN SILENT Length (L) 1150 mm 1910 mm Width (W) 520 mm 860 mm Height (H) 1320 mm 1265 mm Net Weight 300 kg 742 kg Generating Sets POWERED BY: *Ratings at 0.8 pf - Generator designed to operate in ambient temperatures up to 52 o C *Generating Set photo is for reference only. PM9
  • 2. 9. MOUNTING ARRANGEMENT 9.1 BASE FRAME The complete generating set is mounted on heavy duty steel fabricated base frame Which is anti rust coated. 9.2 COUPLING Engine and alternator are directly coupled by means of SAE flange so there is no possibility of misalignment after prolong use. The engine fly wheel is flexibly coupled to the alternator rotor. 9.3 ANTI VIBRATION MOUNTING PADS Anti vibration pads are fitted between engine-alternator base frame ensuring complete vibration isolation of rotating assemblies. 10. FUEL SYSTEM Metal Fuel tank of 180 litres capacity. The Fuel tank is easy to clean and is equipped with visual fuel level indicator. 11. DOCUMENTATION A full set of operation and maintenance manual are provided. 12. FACTORY TESTS Generating set is subject to a strict load test before delivery. A test certificate can be provided as optional. 13. QUALITY STANDARDS Generating set meets the following standards ISO 8528, IEC 34.1, CEI 2.3, VDE 0530, BS 4999-5000, NF51- 100. Perkins is fully accredited ISO 9001 company. 14. WARRANTY Generating set is guaranteed for a period of 12 months from date of commissioning or18 months from date of shipment which ever occurs earlier. (check warranty statement for more details, as it may vary for different countries) In line with our policy of continuous product development, we reserve right to change specification without notice . RATING DEFINITIONS: Prime Power - These ratings are applicable for supplying continuous power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. Standby Power - These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these rating. When used at standby Rating the alternator will be peak continuous rated (according to ISO3046) Generating Sets PM9 1. ENGINE Perkins heavy duty diesel engine. 1.1 GOVERNOR Mechanical, compliance with ISO8528, Class G2. 2. COOLING RADIATOR Radiator and cooling fan complete with protection guards, designed to cool the engine in ambient temperatures up to 52° C. The radiator is mounted on the base frame to avoid vibrations coming from the engine. 3. FILTRATION SYSTEM Cartridge type air filter with security element. Cartridge fuel filter and full lube oil filter. All filters have replaceable elements. 4. EXHAUST SYSTEM Heavy-duty industrial silencer. 5. ELECTRICAL SYSTEM 12 Volt system with battery charging alternator, Starter motor, High capacity maintenance free lead acid battery, battery rack mounted on the generating set base frame, and heavy duty interconnecting cables with terminations. 6. ALTERNATOR Screen protected and drip-proof, self-exciting, self- regulating brush-less alternator. Four poles, STAR winding connection, suitable for tropical, humid and saline climates. H class insulation. 7. AUTOMATIC VOLTAGE REGULATOR (AVR) Static electronic design voltage regulator. Steady voltage precision within + 1 % from no load to full load including cold and hot variations, at any Power factor between 0.8 and unity. 8. MOTOR STARTING An overload capacity equivalent to between 160% to 300% (depending on alternator frame size) of full load impedance at zero power factor can be sustained for 10 seconds. T: +971 4 8833456 F: +971 4 8833458 Warehouse No RA08 XA-04 P. O. Box 17305 Jebel Ali, Dubai, UAE www.adpower.ae sales@adpower.ae STANDARD REFERENCE CONDITIONS Output ratings are presented at 27o C air Inlet temperature, 1000 m bar and 30% relative humidity. Fuel consumption data at various loads, diesel fuel with a specific gravity of 0.85kG/L. De-ration may apply, please consult your dealer for specific site ratings. Some of the specifications are not standard on all Genset Models. Distributed and Serviced by: STANDARD SPECIFICATIONS AVAILABLE OPTIONS & ACCESSORIES We offer a range of optional features and accessories to tailor our generating sets to meet your needs. OPTIONS • Generator Set control and synchronizing panels • Additional Protection alarms and shutdowns • Water fuel separator • Water jacket heater • Battery charger ACCESSORIES • Genuine spare parts • Fuel Tanks • Manual and Automatic Transfer Switches